电池充放电测试仪现场校准方法的研究

电子质量

2018年第09期(总第378期)

电池充放电测试仪现场校准方法的研究

Research on in-situ Calibration Methods of Battery Charge-discharge Instruments

李佳琪,陈凯

(天津市电子仪表实验所,天津300210)Li Jia-qi,Chen Kai (Tianjin Electronic &Instrumental Laboratory,Tianjin 300210)

摘要:电池充放电测试仪的校准工作直接影响充放电电池性能检测的可靠性。该文对充放电测试仪充放电电压、充电电流和放电电流的现场校准方法进行了分析和探讨,并通过一个现场校准实例阐释了电池充放电测试仪的校准流程。

关键词:电池充放电测试仪;校准方法;充电;放电中图分类号:TM933

文献标识码:B

文章编号:1003-0107(2018)09-0081-04

Abstract:The calibration of battery charge-discharge instruments has a directly effect on the testing reliability of batteries.The in-situ calibration methods of the charge and discharge voltage and current of battery charge-discharge instruments are analyzed in this article.An instance of the in-situ calibration is discussed to illustrate the calibration process of battery charge-discharge instruments.

Key words:Battery charge-discharge instrument;Calibration method;charge;discharge CLC number:TM933

Document code:B

Article ID :1003-0107(2018)09-0081-04

作者简介院李佳琪(1992-),男,助理工程师,主要从事电学计量工作;陈凯(1986-),男,工程师,长期从事电学计量工作。

0引言

充电电池由于其经济环保的优势,

广泛应用于各类电子设备和电动设备中,如手机、电动自行车、电动汽车等。在充电电池的使用过程中,

如果使用不当或者维护不及时,有可能出现电池性能下降、失效等现象,严重时甚至产生安全问题,因此需要通过电池充放电测试仪对充电电池的充放电性能进行及时检测。

而充电电池安全性能检验是否可靠依赖于电池充放电测试仪的准确度,因此需要定期对电池充放电测试仪进行校准。由于电池充放电测试仪的体积比较大,

不便于运输,因此一般在电池充放电测试仪的使用现场对其进行校准。

1电池充放电测试仪的计量特性

电池充放电测试仪工作时有两个过程,即充电过程和放电过程[1]。下面对这两个过程进行分析。

充电过程是指电池充放电测试仪对电池进行充电。常规充电过程有三种方法:恒流充电法、恒压充电法和阶段充电法[2]

。其中,恒流充电法是在充电时保持电池充

放电测试仪的充电电流为恒定值,

此时,电池充放电测试仪相当于类电流源,电流参量是主要的校准对象。恒

压充电法是在充电时保持电池充放电测试仪的充电电压为恒定值,而电池端电压不断升高,电流不断减少。此时,电压参量是主要的校准对象。阶段充电法结合了恒流充电和恒压充电的一种快速充电方法,充电电流和电压均是主要的校准对象。

放电过程是指电池充放电测试仪类似于一个电子负载,通过设置的模式消耗恒定的电流或者功率。常规放电过程包括恒流放电、恒功率放电以及恒阻放电。最常用的是恒流放电,在现场校准时,可采用蓄电池作为类电流源,对电池充放电测试仪进行恒流放电,此时,电流参量是主要的校准对象。

2电池充放电测试仪的校准方法

2.1电池充放电测试仪充放电电压的校准

由于电池充放电测试仪体积一般比较大,不便于运输,其校准工作一般在使用现场进行[3]。因此,对电池充放电测试仪电压的校准可采用标准电压源法和标准电压表法进行校准。

标准电压源法是利用标准电压源产生的标准电压对电池充放电测试仪进行校准。此时,被校电池充放电