硅藻泥施工时对墙面湿度和空气湿温度的要求

硅藻泥施工时对墙面湿度和空气湿温度的要求

硅藻泥作为近些年炙手可热的墙面材料,受到了越来越多人的欢迎。不过,由于消费者对于硅藻泥的施工并不熟悉,其实,对于不同的墙面情况,硅藻泥的施工要求也是不同的。

很多人的新房可能是精装房,墙面有的是乳胶漆,有的是壁纸。对于乳胶漆墙面,标准施工流程应该先铲除乳胶漆至底层,然后按照新建建筑墙面进行施工。这样能够保证后期的硅藻泥墙面不开裂。如果消费者不同意铲除乳胶漆层面,则应该先将起鼓、松动的墙面部分进行铲除,然后用腻子找平,再进行硅藻泥施工。

如果是壁纸、墙布等墙面,必须铲除壁纸、墙布等装饰层及底层至水泥砂浆层,然后按照新建建筑墙面施工即可。绝对不可以直接在壁纸、墙布等装饰层基础上直接施工。

对于毛坯房,硅藻泥的施工则对墙面湿度和空气湿温度都有要求。墙面含水率过高或者过低都不利于保证硅藻泥的施工质量。墙面含水率过低,会导致干燥过快,不利于成型机理,同时对于水泥基硅藻泥,也不利于水泥水化胶凝增加强度;墙面含水率过高,会使硅藻泥干燥时间延长,使墙面返碱出现色差。一般情况下,墙面含水率在8%左右为宜。

施工房间的空气湿温度也会影响硅藻泥的施工质量。空气湿度大(大于85%)温度低,硅藻泥干燥时间会延长;空气湿度低(小于20%)温度高,硅藻泥干燥会加快,有可能会影响施工。

相对湿度与露点对照表

室内温度25℃时露点与相对湿度对照表相对湿度露点相对湿度露点0.1% -51.75 4.0% -17.84 0.2% -46.08 4.1% -17.58 0.3% -42.62 4.2% -17.33 0.4% -40.11 4.3% -17.07 0.5% -38.12 4.4% -16.83 0.6% -36.47 4.5% -16.59 0.7% -35.06 4.6% -16.35 0.8% -33.82 4.7% -16.12 0.9% -32.72 4.8% -15.90 1.0% -31.73 4.9% -15.67 1.1% -30.82 5.0% -15.46 1.2% -29.99 6.0% -13.47 1.3% -29.22 7.0% -11.77 1.4% -28.50 8.0% -10.28 1.5% -27.82 9.0% -8.95 1.6% -27.19 10.0% -7.75 1.7% -26.59 11.0% -6.65 1.8% -26.03 1 2.0% -5.64 1.9% -25.49 13.0% -4.71 2.0% -24.98 14.0% - 3.83 2.1% -2 4.49 1 5.0% -3.02 2.2% -24.02 1 6.0% -2.25 2.3% -23.57 1 7.0% -1.15 2.4% -23.14 1 8.0% -0.83 2.5% -22.73 1 9.0% -0.15 2.6% -22.33 20.0% 0.50 2.7% -21.94 30.0% 6.24 2.8% -21.57 40.0% 10.48 2.9% -21.20 50.0% 1 3.86 3.0% -20.85 60.0% 16.70 3.1% -20.51 70.0% 19.15 3.2% -20.18 80.0% 21.31 3.3% -19.86 90.0% 23.24 3.4% -19.55 3.5% -19.25 3.6% -18.95 3.7% -18.67 3.8% -18.39 3.9% -18.11

硅藻泥施工工艺流程

硅藻泥施工工艺流程 了解硅藻泥施工流程,做到心中有数。由于硅藻泥具有很好的可塑性,施工简单快捷、款式花色多样、可随意造型等特点而受到大家的喜爱。那么硅藻泥施工流程是怎么样的呢?很多人其实并不了解,和小编一起来看看吧,让我们做到心中有数。 【硅藻泥施工工艺流程】 硅藻泥施工工具 施工工具一般有手提电动搅拌器,镘刀,脚踏梯,量水器皿,20升干净的白乳胶桶2~3个,美纹胶纸等防护用品,刷子、抹布等清扫用品。硅藻泥为粉状材料,施工前需准备好,并计算好用量。硅藻泥产品一般会标明每公斤硅藻泥的施工面积。因此可以测量好施工的面积,确定肌理图案,据此确认所需硅藻泥壁材的数量。 硅藻泥施工步骤 硅藻泥施工的流程大致是这样的:墙面清理→底层腻子→基层腻子打磨→第一遍硅藻泥→第二遍硅藻泥→硅藻泥图案制作→成品保护→验收,下面的详细的操作过程: 1、基层处理 我们知道无论墙面装修是用什么材料,都需要对墙面基层进行处理的。墙面基层处理一般就是平整墙面、防开裂处理和防水处理,需要批刮腻子和涂刷封闭底漆。基层处理注意选用环保材料,尽量选择环保等级高的辅材。 2、调配硅藻泥 1)加适量的水

做好基层处理之后,就可以调配硅藻泥了。准备好材料和工具,根据加水比例加水,最好用量杯。避免直接打开水龙头将水注入桶中,凭经验确定水量。 2)加色浆 如果客户要的是有颜色的图案,就需要加入色浆。但是要注意不是所有的色浆都能够与材料相容,加入的色浆必须是与同一品牌产品相配使用的色浆。自行决定色浆时要事先测试,搅拌时,注意搅拌到桶底部,将色浆搅拌至分散均匀为止。 3)加硅藻泥 拆包装袋前要先清除包装袋外表的污物,用剪刀打开包装袋封口。先将7成材料慢慢倒入桶中,然后使用搅拌器搅拌,待干粉和色浆水完全混合后,再将剩余的材料倒入桶内,继续搅拌,直到材料成为细腻的膏状(没有颗粒状、结块状)为止。正式施工前再搅拌几分钟。 3、制作肌理 用工具即可,目前硅藻泥肌理制作大多是借助各种各样的工具做成的。 4、硅藻泥机理制作与养护 硅藻泥施工方法更加多样,施工效果也随着施工方法不同而不同。硅藻泥墙面肌理制作方法有:平光法,喷涂法,艺术法,根据自己的需求选择合适的施工方法。 5、硅藻泥墙面成品保护 硅藻泥墙面完全干燥一般需要48小时,在48小时内不要触摸它。48小时后可以用喷壶喷洒少量清水,干燥后用干的干净毛巾或海绵泡沫去除表面浮料。在施工过程中,注意不要使用空调、风扇或开窗通风。干燥过快,会增加了肌理施工难度。 6、硅藻泥墙面的养护 硅藻泥墙面清洁时,需要针对不同的污渍情况,选择不同的清洁方法。注意避免错误的清洁保养方法,防止清洁不成,反造成更大破坏。比如前面提到的硅藻泥墙面不能用水洗或带水的湿布擦拭。 【硅藻泥施工注意事项】 1、在储存及运输过程中,注意防水、防潮,避免直接放在潮湿的地面上。 2、施工时相对湿度必须小于80%,基面含水率小于10%。 3、面料施工温度-5~40℃,夏天避免在阳光直射处施工。

空气的湿度与人类生活

1.对一定质量的理想气体,下列状态变化中不.可能的是( ) A .使气体体积增大,同时温度降低、压强减小 B .使气体温度升高,体积不变、压强减小 C .使气体温度不变,而压强、体积同时增大 D .使气体温度降低,压强减小、体积减小 解析:选BC.根据理想气体状态方程pV T =C 知,V 增大,T 降低,如果压强减小,A 可以实现;同理,D 可以实现,B 、C 不可以实现,因此选B 、C. 2.一定质量的某种理想气体的压强为p ,热力学温度为T ,单位体积内气体分子数为n ,则( ) A .p 增大时,n 一定增大 B .T 减小时,n 一定增大 C .p /T 增大时,n 一定增大 D .p /T 增大时,n 一定减小 解析:选C.单位体积内气体分子数n 与体积V 有直接关系,V 增大时,n 一定减小.由pV T = C 得p T 增大时,V 减小,此时n 一定增大,故只有C 选项正确. 3.一定质量的理想气体,初始状态为p 、V 、T ,经过一系列状态变化后,压强仍为p ,则 下列过程中可以实现的是( ) A .先等温膨胀,再等容降温 B .先等温压缩,再等容降温 C .先等容升温,再等温压缩 D .先等容降温,再等温压缩 解析:选BD.根据理想气体的状态方程pV T =C ,若经过等温膨胀则T 不变,V 增大,再经等容降温则V 不变,T 减小,则pV T =C 可知,V 增大,T 减小,p 一定变化,A 不正确;同理可以判断出C 不正确,B 、D 正确. 4.一个半径为 cm 的气泡,从18 m 深的湖底上升.如果湖底水的温度是8 ℃,湖面的温度是24 ℃,湖面的大气压强是76 cmHg ,那么气泡升至湖面时体积是多少

空气温度湿度对照表

空气绝对湿度与空气相对湿度这两个物理量之间并无函数关系。例如,温度越高,水蒸发得越快,于是空气里的水蒸汽也就相应地增多。所以在一天之中,往往是中午的绝对湿度比夜晚大。而在一年之中,又是夏季的绝对湿度比冬季大。但由于空气的饱和水汽压也随着温度的变化而变化,所以又可能是中午的相对湿度比夜晚的小。由于在某一温度时的饱和水汽压可以从“不同温度时的饱和水汽压”表中查出数据,因此只要知道当前气温,算出当前空气中的水汽压,即可求出空气相对湿度来。 前言:空气有吸收水分的特征,PCB主料和辅料有相当部分也是对湿度十分敏感的材料,它们遇到空气中的相对湿度比工艺条件高或低时会吸湿或缩水造成自身形体变化,如黑菲林、重氮片、半固化片等。造成制程中不稳定的质量缺陷。今天我们来谈谈空气一个状态的参数——相对湿度。 生产中的相对湿度是由工业除湿机组和超声波加湿器自动调节的,当生产过程相对湿度局部出现小偏差,我们可以通过局部加减湿度来满足生产需求。例如直接喷水、开启超声波雾化加湿器设备、煮开水来增加空气湿度、开启除湿机及抽湿机,升温可以降低空气湿度。 湿度的概念是空气中含有水蒸气的多少。它有三种表示方法: 第一是绝对湿度,它表示每立方米空气中所含的水蒸气的量,单位是克/立方米;

第二是含湿量,它表示每千克干空气所含有的水蒸气量,单位是克/千克·干空气; 第三是相对湿度,表示空气中的绝对湿度与同温度下的饱和绝对湿度的比值,得数是一个百分比。(也就是指在一定时间内,某处空气中所含水汽量与该气温下饱和水汽量的百分比。) 相对湿度用RH表示。相对湿度的定义是单位体积空气内实际所含的水气密度(用d1 表示)和同温度下饱和水气密度(用d2 表示)的百分比,即RH(%)= d1/ d2 x 100%;另一种计算方法是:实际的空气水气压强(用p1 表示)和同温度下饱和水气压强(用p2表示)的百分比,即RH(%)= p1/ p2 x 100%。 前两种湿度表示它的计算结果是一个量化,并未能满足空气可利用的工艺状态,而我们工艺生产条件更注重空气状态,所以相对湿度是我们最常用衡量空气湿度的一种指标。饱和空气:一定温度和压力下,一定数量的空气只能容纳一定限度的水蒸气。当一定数量的空气在该温度和压力下最大限度容纳水蒸气,这样的空气称饱和空气;未能最大限度容纳水蒸气,这样的空气称未饱和空气。假如空气已达到饱和状态,人为的把温度下降,这时的空气进入一个过饱和状态,水蒸气开始以结露的形式从空气中分离出来变成液态水,这就是我们抽湿机的工作原理。

硅藻泥墙面装修施工方法

硅藻泥墙面装修施工方法 硅藻泥作为新型的建筑材料被大众熟知。硅藻泥是一种以硅藻土为主要原材料的内墙环保装饰壁材,具有消除甲醛、净化空气、调节湿度、释放负氧离子、防火阻燃、墙面自洁、杀菌除臭等功能。其环保健康的魅力让更多人喜欢在家居中使用它们。 许多没用过硅藻泥的家装客户和施工队伍如果对硅藻泥施工不熟,很可能会让装修效果打折扣。硅藻泥在新墙面上施工,要多注意这些细节,尤其是墙面碱度和空鼓现象,避免做后出现问题,影响硅藻泥效果和业主的心情。那么硅藻泥墙面装修施工方法具体有哪些呢? 硅藻泥墙面装修施工方法一、新墙面需有足够养护期。 一般需保养1个月,如冬季低温或潮湿地区保养期需适当延长,确保墙体湿度小于10%。可用专用仪器(液晶显示式双探头墙体测湿仪)进行墙体湿度的检测。

硅藻泥墙面装修施工方法二、墙体碱度须小于10,一般新墙用水泥砂浆抹涂结束后。 湿态其碱性为14,养护1个月左右其PH值可降至8,可用清水浇湿墙面,然后用精密PH试纸粘附墙体数秒钟后测试PH值。 硅藻泥墙面装修施工方法三、检查底材有无空鼓,裂缝现象。 墙体空鼓将严重影响涂层的附着力,通常采用目测、敲打、硬器划刻、手抹等方法检查。发现有空鼓现象,必须彻底铲除,应用配套腻子修补平整或用与墙体砂浆比例一致的水泥砂浆按墙体同样施工方法进行修补填平,确保涂层吸收一致,无接痕。墙体裂缝严重影响涂层的装饰美观性能。发现裂缝应用专用填补腻子填补修复,较大空心裂缝可先用砂浆修补后抹平。 硅藻泥墙面装修施工方法四、墙体浮砂、灰砂的处理。

涂装施工前用铲刀或刮刀铲去一遍或用钢丝刷处理清除,也可用硬毛竹扫把清除浮砂。墙体砂眼,凹坑如脚手架洞、空调洞、窗套、管道设施铺设遗漏留缺陷,需用与墙体基面同类材质和施工方法进行处理。这一点往往在施工中不被注意。但硅藻泥上墙后易发现发花不协调,严重影响装饰效果。 硅藻泥墙面装修施工方法五、基面抹灰的搭接痕。 底材的搭接痕不平整将影响装饰的美观度。施工前须用打磨机打磨平整。 硅藻泥墙面装修施工方法六、墙体铁钉头。 施工涂装前应切割露出铁钉并敲没墙体,然后用防锈漆对钉头进行处理。 以上就是硅藻泥墙面装修施工的方法,硅藻泥现在应用还较少,因此很多业主和施工队在铺设的时候一定要按照施工的要求和步骤来完成。

硅藻泥施工方案

硅藻泥施工方案 1、施工准备 1)技术准备 编制墙面硅藻泥施工方案,并对工人进行书面技术交底; 2)材料准备 符合设计要求的硅藻泥,应有产品合格证及检测报告、环保指标达到国家有关标准,应有存储有效期和产品合格证,品种、颜色应符合设计要求; 3)工具准备 搅拌器、水桶(至少2个,搅拌料桶和接水桶);泡沫、抹刀(披灰和收光);刮板、小刷子、小铲刀、毛巾(至少两条);梯子、多齿工具;树皮棍子、卷尺(7500mm);红外线测量仪(大面积测量);室内空气甲醛检测仪;专用地膜工作服、鞋套、美纹纸(进口做造型用和国产保护墙角用)等;如有施工图案弹涂需携带空压机、喷枪、连接线等相关工具及设备。 4)人员准备 配备充足作业人员,且涂刷作业时操作工人应配戴相应的劳动保护设施。 5)施工墙面条件要求 保证基面平整、密实、清洁、阴阳角及线条横平坚直,结冰.渗水墙面禁止施工;抹灰作业全部完成,过墙的管道、洞口、阴阳角等处应提前抹灰找平修整,并充分干燥,墙面裂缝位置请提前处理好;将混凝土过梁、梁垫、圈梁、混凝土柱、梁等表面突出部分剔平。脚手眼和废气的孔洞应堵严,外露钢筋头、铅丝头及木头等要剔除并做防锈处理,窗台砖补齐,墙与楼板、梁底等交接处应用斜砖砌严补齐;对于空鼓或出现裂纹的基底须预先处理,清洁后对基底涂刷二遍腻子; 6)施工环境条件要求 墙体温度在5℃以上,空气相对湿度不大于80%,阴雨天气严禁施工;施工现场环境温度和墙体表面温度在施工及施工后24小时内不得低于5℃,施工时风力不大于5级。若低于+5℃则应停止施工;夏季温度36℃以上不应施工。若必须施工,则应采取遮阳措施,避免阳光直射;雨天不宜施工,若必须施工则应用防雨布覆盖保护; 2、调和搅拌 铺好专用地膜,施工前做好已有成品的保护工作,施工面以外的地方预先进行保护;用小铲刀处理墙面平整度;用国产美纹纸保护好门边.墙角及踢脚线、插

湿度空气计算方法

相对湿度、露点温度转换的基本原理说明 湿度研究对象是气体和水汽的混合物。 无论是对于自由大气中的空气而言,还是对密闭容器中的特定气体而言,但凡是气体和水汽的混合物,都可以作为湿度的研究对象,湿度研究的一般理论大多都是通用的。 湿度的表示方法很多,包括混合比、体积比、比湿、绝对湿度、相对湿度等等,虽然各单位之间的转换非常复杂,但其定义都是基于混合气体的概念引出的。相对湿度是比较常用的湿度单位,是一个相对概念(所以,相对湿度是一个无量纲单位),主要有以下几种定义表达: 1、 压力为P,温度为T的湿空气的相对湿度,是指在给定的湿空气中,水汽的摩尔分数(或实际水汽压)与同一温度T和压力P下纯水表面的饱和水汽的摩尔分数(或饱和水气压)之比,用百分数表示。 2、实际水汽压与同一温度条件下的饱和水汽压的比值 从相对湿度的定义中可以看出,相对湿度的计算,是通过混合气体的实际水汽压与同状态下(温度、压力)水汽达到饱和时其饱和水汽压相比得来的。 对于混合气体而言,其实际水汽压与总压力和混合比相关,但对于物质的量而言,是独立的,也就是无相关的。但是,在保持混合气体压力不变的情况下,混合气体的饱和水汽压是与温度相关的(在湿度论坛中,本人给出了温度to饱和水汽压的简化公式以及计算程序,可下载)。 上面说道:饱和水汽压是与温度相关的量。 在保持系统的混合比、总压力不变的情况下,降低混合气体的温度,能够降低混合气体的饱和水汽压,从而使得混合气体的饱和水汽压等于混合气体的实际水汽压,此时,相对湿度为100%,该温度,即为混合气体的露点温度。 基于上述解释,可以看出,只要测量得到了露点温度,通过温度to饱和水汽压的计算公式或者计算程序,即可计算出混合气体的在露点温度时的饱和水汽压,也就是正常状态下混合气体的实际水汽压。 同样,只要测量了当前混合气体的正常温度,就可以通过温度to饱和水汽压的计算公式或者计算程序,得到当前系统正常温度下的饱和水汽压 实际水汽压除以饱和水汽压,就可以得到相对湿度。 湿度的单位换算 测湿仪表的显示值,通常是相对湿度或露点温度,在需要用其它单位时可进行换算。换算的方法如下: 1.相对湿度与实际水汽压间的换算 由相对湿度的定义可得: ---------------------------(1) 式中:RH----相对湿度,%RH; e----实际水汽压,hPa; E---饱和水汽压,hPa。 因此: -------------------------------(2) 即:实际水汽压等于相对湿度乘以相同温度下的饱和水汽压。 由于饱和水汽压E是温度的函数,所以用相对湿度换算为实际水汽压或用实际水汽压计算相对湿度,都必须已知当时的温度值。在计算饱和水汽压时,应确定是冰面还是水面,以正确选用计算公式。 2.相对湿度换算为露点温度 由于露点温度定义为空气中的水汽达到饱和时的温度,所以,必须先计算出实际水汽压。根据露点的定义,这时的水汽压就是露点温度对应的饱和水气压。因此,可以用对饱和水汽压求逆的方法计算露点温度。 用Goff-Grattch方程求逆非常困难,常用饱和水汽压的简化公式计算,而 简化公式很多,一般采用国军标GJB1172推荐的公式: ----------(3) 式中:E------为饱和水汽压,Pa;

空气温度湿度对照表

单位体积空气中所含水蒸汽的质量,叫做空气的“绝对湿度”。它实际上就是水汽密度。它是大气干湿程度的物理量的一种表示方式。通常以1立方米空气内所含有的水蒸汽的克数来表示。单位为克/立方米或克/立方厘米。水蒸汽的压强是随着水蒸汽的密度的增加而增加的,所以,空气里的绝对湿度的大小也可以通过水汽的压强来表示。由于水蒸汽密度的数值与以毫米高水银柱表示的同温度饱和水蒸汽压强的数值很接近,故也常以水蒸汽的毫米高水银柱的数值来计算空气的干湿程度。空气中实际所含水蒸汽密度和同温度下饱和水蒸汽密度的百分比值,叫做空气的“相对湿度”。空气的干湿程度和空气中所含有的水汽量接近饱和的程度有关,而和空气中含有水汽的绝对量却无直接关系。例如,空气中所含有的水汽的压强同样等于1606.24pa(12.79毫米汞柱)时,在炎热的夏天中午,气温约35℃,人们并不感到潮湿,因此时离水汽饱和气压还很远,物体中的水分还能够继续蒸发。而在较冷的秋天,大约15℃左右,人们却会感到潮湿,因这时的水汽压已经达到过饱和,水分不但不能蒸发,而且还要凝结成水,所以我们把空气中实际所含有的水汽的密度ρ1与同温度时饱和水汽密度ρ2的百分比ρ1/ρ2×100%叫做相对湿度。也可以用水汽压强的比来表示露点温度是指空气在水汽含量和气压都不改变的条件下,冷却到饱和时的温度。形象地说,就是空气中的水蒸气变为露珠时候的温度叫露点温度。露点温度本是个温度值,可为什么用它来表示湿度呢?这是因为,当空气中水汽已达到饱和时,气温与露点温度相同;当水汽未达到饱和时,气温一定高于露点温度。所以露

点与气温的差值可以表示空气中的水汽距离饱和的程度。在100%的相对湿度时,周围环境的温度就是露点温度。露点温度越小于周围环境的温度,结露的可能性就越小,也就意味着空气越干燥,露点不受温度影响,但受压力影响。湿球温度的定义是在定压绝热的情况下,空气与水直接接触,达到稳定热湿平衡时的绝热饱和温度。

硅藻泥施工工艺方法

硅藻泥施工工艺方法 施工工艺流程: 基层抗裂砂浆处理→挂玻璃纤维网→刮腻子→打磨平滑→乳胶漆底漆→肌理涂料面层 墙面肌理涂料工程的施工要点: 1.基层处理是保证施工质量的关键环节,其中保证墙体完全干透是最基本条件,因为水泥做粘结材料的砂浆,未硬化前呈强碱性,此时涂刷必然泛碱。当水泥砂浆硬化后,碱性值大幅度下降,此时方可进行涂刷;为防止墙面开裂,铺设玻璃纤维网。干透时间因气候条件而异,一般应放置10天以上。墙面必须平整,最少应满刮两遍腻子,如仍达不到标准,应加刮至满足标准要求。 2.肌理涂料的施工方法可以采用手刷、滚涂和喷涂。可与滚涂相结合,具体方法是:大面积是使用滚涂,边角部分使用手刷,这样既提高涂刷效率,又保证了涂刷质量。施工时肌理涂料必须充分搅拌后方能使用。 3.滚涂是使用肌理涂料专用滚筒进行涂饰,其技术要领为:将肌理涂料搅拌均匀,粘稠度调至适合施工后,滚动辘筒使肌理涂料均匀适量地附于辘筒上。墙面涂饰时,先使毛辗按W式上下移动,将肌理涂料大致涂抹在墙上,然后按住辘筒,使之靠紧墙面,上下左右平稳地来回滚动,使肌理均匀展开。滚涂至接茬部位时,应使用不沾涂料的空辗子滚压一遍,以免接茬部位不匀而露出明显痕迹。 4.喷涂是利用压力或压缩空气,通过喷枪将乳胶漆喷在墙上,其操作技术要领为:首先应调整好空气压缩机的喷涂压力,一般在0.4~0.8兆帕范围之内,具体施工时应按乳胶漆产品使用说明书调整。喷涂作业时,手握喷枪要稳,乳胶漆出口应与被涂饰面垂直,喷枪移动时应与涂饰面保持平行,喷枪运动速度适当并且应保持一致,一般每分钟应在400~600毫米间匀速运动。 5.喷涂时,喷枪嘴距被涂饰面的距离应控制在400~600毫米之间,喷枪应直线平行或垂直于地面运动,移动范围不能太大,一般直线喷涂700~800毫米后,拐弯180。反向喷涂下一行,两行重叠宽度应控制在喷涂宽度的l/3左右。

绝对湿度与相对湿度对照表

5%10%15%20%25%30%35%40%45%50%55% 60%65%70%75%80%85%90%95%100%5℃0.340.68 1.02 1.36 1.70 2.04 2.38 2.72 3.06 3.40 3.73 4.07 4.41 4.75 5.09 5.43 5.77 6.11 6.45 6.7910℃0.470.94 1.41 1.88 2.35 2.82 3.29 3.76 4.23 4.70 5.16 5.63 6.10 6.577.047.517.988.458.929.3915℃0.64 1.28 1.92 2.56 3.21 3.85 4.49 5.13 5.77 6.417.057.698.338.979.6210.2610.9011.5412.1812.8220℃0.86 1.73 2.59 3.45 4.32 5.18 6.04 6.917.778.649.5010.3611.2312.0912.9513.8214.6815.5416.4117.2725℃ 1.15 2.30 3.45 4.60 5.75 6.908.059.2010.3511.5112.6613.8114.9616.1117.2618.4119.5620.7121.8623.0130℃ 1.52 3.03 4.55 6.067.589.0910.6112.1213.6415.1616.6718.1919.7021.2222.7324.2525.7627.2828.7930.3135℃ 1.98 3.95 5.937.909.8811.8513.8315.8017.7819.7621.7323.7125.6827.6629.6331.6133.5835.5637.5339.5140℃ 2.55 5.107.6510.2012.7515.3017.8520.4022.9525.5028.0530.6033.1535.7038.2540.8043.3545.9048.4551.0045℃ 3.26 6.529.7813.0416.3019.5622.8226.0829.3432.6135.8739.1342.3945.6548.9152.1755.4358.6961.9565.2150℃ 4.138.2712.4016.5320.6624.8028.9333.0637.1941.3345.4649.5953.7257.8661.9966.1270.2574.3978.5282.6555℃ 5.1910.3915.5820.7825.9731.1736.3641.5646.7551.9557.1462.3367.5372.7277.9283.1188.3193.5098.70103.8960℃ 6.4812.9519.4325.9132.3938.8645.3451.8258.2964.7771.2577.7284.2090.6897.16103.63110.11116.59123.06129.5465℃8.0216.0324.0532.0640.0848.0956.1164.1272.1480.1588.1796.18104.20112.21120.23128.24136.26144.27152.29160.3070℃9.8519.6929.5439.3949.2459.0868.9378.7888.6298.47108.32118.16128.01137.86147.71157.55167.40177.25187.09196.9475℃12.0224.0336.0548.0660.0872.0984.1196.12108.14120.16132.17144.19156.20168.22180.23192.25204.26216.28228.29240.3180℃14.5729.1343.7058.2772.8387.40101.97116.53131.10145.67160.23174.80189.36203.93218.50233.06247.63262.20276.76291.3385℃17.5535.1052.6570.2087.75105.29122.84140.39157.94175.49193.04210.59228.14245.69263.24280.78298.33315.88333.43350.9890℃21.0242.0463.0584.07105.09126.11147.13168.14189.16210.18231.20252.22273.23294.25315.27336.29357.31378.32399.34420.3695℃25.0350.0675.09100.12125.15150.18175.21200.24225.27250.30275.33300.36325.39350.42375.45400.48425.51450.54475.57500.60100℃ 29.65 59.30 88.94 118.59 148.24 177.89 207.54 237.18 266.83 296.48 326.13 355.78 385.42 415.07 444.72 474.37 504.02 533.66 563.31 592.96 绝对湿度与相对湿度对应表(大气压:1bar) 相对湿度 (RH) 绝对湿度 g/m 3 温度

硅藻泥效果图片大全

硅藻泥,对于装修的人士并不陌生,那选择什么样的硅藻泥效果那,今天大森林硅藻泥小编为大家介绍几组硅藻泥效果图片,由于硅藻泥健康环保,不仅有很好的装饰性,还具有功能性,是替代壁纸和乳胶漆的新一代室内装饰材料,所以很多家庭在装修时都会选择硅藻泥作为墙面的装饰,接下来就为大家带来这几组好看又健康的硅藻泥效果图片大全。 硅藻泥选用无机矿物颜料调色,色彩柔和,墙面反射光线自然柔和,让人不容易产生视觉疲劳。暖白色的硅藻泥背景墙为卧室增添了温馨与活力,绿色的盆栽图案趣味十足,蝴蝶造型的装饰让单色调的背景墙不再单调。 带有古典中式图案的硅藻泥背景墙抢占进入客厅的人的视线,且硅藻泥材质

能令墙面颜色持久,长期保持如新。但占据整个墙面的图案让客厅在视觉上显得过于拥挤,简约的墙面装饰或许会好一些。 硅藻泥可以吸收或释放水分,自动调节室内空气湿度,使之达到相对平衡,因此在沿海城市和南方空气较湿润的城市,硅藻泥背景墙的选择很关键。效果图中浅绿色硅藻泥背景墙简约低调,几个花朵的点缀似乎让背景墙有了生命一般。 灰色的硅藻泥背景墙为客厅营造了低调、安详的幽静氛围,且硅藻泥的材质具有很强的吸音降噪的功能,为餐厅处安静的氛围提供了物理上的保障。在背景墙上添加上花朵点缀,让简约的卧室更显时尚年轻。 环保健康硅藻泥先选大森林硅藻泥,大森林一直坚定注理想、踏实做产品、

稳步树品牌、执着为健康,大森林硅藻泥秉承“树行业品牌,创美好生活”的企业愿景,全力打造高品质的环保产品、具影响力的行业品牌,通过不断创新及很佳质的经营服务,将大森林硅藻泥铸造成行业中的旗帜性品牌。 大森林硅藻泥现为厦门两岸股权交易中心挂牌企业、中国建筑装修材料协会硅藻泥材料分会副会长单位、《水性硅藻泥质量标准》起草单位《硅藻泥装饰壁材应用技术规程》起草单位、被评为国家AAA级信用企业公司直营,保证材料为正品,服务更有保障,价格更加优惠,性价比更高! VR、效果图详情请点击https://www.360docs.net/doc/744367841.html,了解,材料采购请点击https://https://www.360docs.net/doc/744367841.html,选购。

温度与相对湿度要点

温度与相对湿度、绝对湿度、饱和湿度的关系 绝对湿度 (1)定义或解释 ①空气里所含水汽的压强,叫做空气的绝对湿度。 ②单位体积空气中所含水蒸汽的质量,叫做空气的绝对湿度。 (2)单位 绝对湿度的单位习惯用毫米水银柱高来表示。也常用l 立方米空气中所含水蒸汽的克数来表示。 (3)说明 ①空气的干湿程度和单位体积的空气里所含水蒸汽的多少有关,在一定温度下,一定体积的空气中,水汽密度愈大,汽压也愈大,密度愈小,汽压也愈小。所以通常是用空气里水蒸汽的压强来表示湿度的。 ②湿度是表示空气的干湿程度的物理量。空气的湿度有多种表示方式,如绝对湿度,相对湿度、露点等。 相对湿度 2 5 4P su x =? (1)定义或解释 ①空气中实际所含水蒸汽密度和同温度下饱和水蒸汽密度的百分比值,叫做空气的相对湿度。 ②在某一温度时,空气的绝对湿度,跟在同一温度下的饱和水汽压的百分比值,叫做当时空气的相对湿度。 (2)说明 ①实际上碰到许多跟湿度有关的现象并不跟绝对湿度直接有关,而是跟水汽离饱和状态的程度有直接关系,因此提出了一个能表示空气中的水汽离开饱和程度的新概念——相对湿度。也是空气湿度的一种表示方式。 ②由于在温度相同时,蒸汽的密度和蒸汽压强成正比,所以相对湿度通常就是实际水蒸汽压强和同温度下饱和水蒸汽压强的百分比值。 露点 (1)定义或解释 ①使空气里原来所含的未饱和水蒸汽变成饱和时的温度,叫做露点。 ②空气的相对湿度变成100%时,也就是实际水蒸汽压强等于饱和水蒸汽压强时的温度,叫做露点。 (2)单位 习惯上,常用摄氏温度表示。 (3)说明 ①人们常常通过测定露点,来确定空气的绝对湿度和相对湿度,所以露点也是空气湿度的一种表示方式。例如,当测得了在某一气压下空气的温度是20℃,露点是12℃那么,就可从表中查得20℃时的饱和蒸汽压为17.54mmHg ,12℃时的饱和蒸汽压为lO.52mmHg 。则此时:空气的绝对湿度p=10.52mmHg , 空气的相对湿度.B=(10.52/17.54)×100%=60%。 采用这种方法来确定空气的湿度,有着重大的实用价值。但这里很关键的一点,要求学生学会露点的测定方法。 ②露点的测定,在农业上意义很大。由于空气的湿度下降到露点时,空气中的水蒸汽就凝结成露。如果露点在O℃以下,那末气温下降到露点时,水蒸汽就会直接凝结成霜。知道了露点,可以预报是否发生霜冻,使农作物免受损害。 ⑨气温和露点的差值愈小,表示空气愈接近饱和。气温和露点接近,也就是此时的相对湿度百分比值大,人们感觉气候潮湿;气温和露点差值大,即此时的相对湿度百分比值小,人们感觉气候干燥。人体感到适中的相对湿度是60~70%。 ④严格地说,露点时的饱和汽压和空气当时的水汽压强是不相等的。

七年级生物测量不同植被环境的空气温度和湿度

测量不同植被环境的空气温度和湿度 植物体内的水分以水蒸气的形式通过叶片散失到体外的生理过程叫蒸腾作用。植物通过蒸腾作用会影响周围环境的空气温度和湿度。 环境中植被类型不同,蒸腾作用的程度有所差异,我们可以通过比较三种不同植被环境的空气温度和湿度来了解生物对环境的影响。活动以小组为单位进行,每组4~6人。 【活动目标】 1.学会用干湿计测量裸地、草坪和灌木丛的空气温度和湿度的方法; 2.分析实测的数据,说明不同植被对环境温度和相对湿度的影响; 3.练习使用坐标图表示实验结果。 【材料器具】 干湿计一支、手表一块、伞或其他遮阴物。 【方法步骤】 1.在你的笔记本中准备3份用于记录的表格(如下表),分别用于早、中、晚不同时间的实测记录。 日期:时间:测量者: 2.在你们的校园里或住所周围选择三个植被环境差异足够显著的测量地点,你们的选择是:()、()、()。 3.分别在一天之中的早、中、晚确定三个可能的测量时间,你们的选择是:早()、中()、晚()。 4.每个实测地点要测量3个数据,间隔时间8 min,将3个数据和其平均值分别记录在表格中。 5.实验开始之前,你们需要做好以下的准备: 明确小组成员之间的分工;

反复练习,熟练使用干湿计; 测量时应将干湿计摆放在什么位置?(可以讨论一下) 6.进行测量。 7.根据测量记录绘制曲线图(取3个数据的平均值)。 下面两个坐标图,横轴表示早、中、晚三个测量时间;纵轴分别表示温度和湿度。将同一地点(如草坪)在早、中、晚测量的温度(湿度)平均值用圆点的方式标在图中相应位置上,将三个点连线便可以绘出一条曲线。你可以用三种不同形式的曲线表示三个不同的测量地点(如下图)。

硅藻泥施工工艺

硅藻泥施工工艺 1施工准备 1.1技术准备 1.1.1编制墙面硅藻泥施工方案,并对工人进行书面技术及安全交底。 1.1.2施工前应组织进行样板施工,样板经确认后方可进行大面积施工。 1.2材料准备 1.2.1硅藻泥:符合设计要求的硅藻泥,应有产品合格证及检测报告、产品说明书、环保指标达到国家有关标准。 1.2.2基层腻子:采用耐水腻子粉。 1.2.3界面剂:采用界面剂。 1.3施工机具 脚手架、小铁锹、擦布、开刀、胶皮刮板、钢片刮板、腻子托板、扫帚、小桶、大桶、排笔、刷子 1.4施工作业条件 1.4.1保证基面平整、密实、清洁,含水率小于10%,PH值小于10,阴阳角及线条横平坚直;基层的偏差应小于2mm。 1.4.2抹灰作业全部完成,过墙的管道、洞口、阴阳角等处应提前抹灰找平修整,并充分干燥。 1.4.3将混凝土过梁、梁垫、圈梁、混凝土柱、梁等表面突出部分剔平,将蜂窝、麻面、露筋、疏松部分剔到实处,并刷胶粘性素水泥或界面剂。然后用1:3的水泥砂浆分层抹平。脚手眼和废气的孔洞应堵严,外露钢筋头、铅丝头及木头等要剔除并做防锈处理,窗台砖补齐,墙与楼板、梁底等交接处应用斜砖砌严补齐。 1.4.4硅藻泥施工前应熟悉图纸、设计说明及其他设计文件,制定方案,做好样板间,经检验达到要求标准后方可正式施工。 2.4.5腻子前应先搭好脚手架或准备好高马凳,架子应离开墙面20~25cm,便于操作。 2.4.6做好样板间,并经检查鉴定合格后,方可组织大面积施工。 三、关键质量要点 3.1材料的关键要求 3.1.1应有使用说明、存储有效期和产品合格证,品种、颜色应符合设计要求。 3.1.2材料选用必须符合《建筑工程室内环境污染控制规范》(GB50325-2001)的要求,并具备国家环境检测机构出具的有关有害物质限量等级检测报告。 3.2技术关键要求 3.2.1基层腻子应挂实磨平达到牢固、无粉化、起皮和裂缝。 3.2.2涂刷均匀、粘结牢固,不得漏涂、无透底、起皮和反锈。 3.2.3应采用具有耐水性腻子。 3.2.4硅藻泥施工必须在基层腻子干燥后进行。 3.3质量关键要求 3.3.1残缺处应补齐腻子,砂纸打磨到位。应认真按照规程和工艺标准去操作。 3.3.2基层腻子应平整、坚实、牢固、无粉化、起皮裂缝。 3.3.3硅藻泥施工温度-5~40℃,夏天避免在阳光直射处施工 3.4职业健康安全关键要求

环境湿度基本常识(附常温下的饱和湿度表)

湿度的基本概念 空气中含有一定量的水蒸气,来自江河湖海和土壤水分的不断蒸 发。空气中的水蒸气含量越多,就越潮湿,反之就越干燥。空气中的 干燥和潮湿程度,就叫空气的湿度。空气的湿度通常有以下几个概念: 1.绝对湿度(absolute humidity) 单位体积内的空气中,实际所 含的水蒸气量,称为空气的绝对湿度。用密度单位“g/m3”表示。如lm3 的空气中含有10.8g水蒸气,绝对湿度就是10.8g/m3。某温度下的 绝对湿度,也可以用水汽压强单位毫米高水银柱( mmHg)近似地表 示。如水汽压强是8mmHg,绝对湿度可近似地表示为8g/m3。湿度 与温度和水的蒸发强度有直接的关系,一般温度高,蒸发到空气中的 水汽就多,绝对湿度就大,反之就小。绝对湿度与温度成正比。 设空气的水汽密度为ρv,与之相对应的水蒸气分压为Pv,则 根据理想气体状态方程有如下关系 ρv=PvM/RT (1) 式中,M为水汽的摩尔气体质量;R为摩尔气体常数;T为绝 对温度。 2.饱和湿度(saturated humidity)在一定温度下,空气中水蒸气 的最大含量,称为饱和湿度。饱和湿度的单位以g/m3表示。在一定 的温度下,空气中的水蒸气含量不会无限制地增多。当空气中的水蒸 气含量达到最大限度时,空气中的水蒸气量就达到饱和。大气是由干

空气和水蒸气组成的混合气体,大气具有一定的压强,就是通常所说 的大气压。水蒸气也具有一定的压强,称为水蒸气分压力。大气压等 于空气的分压力与水蒸气分压力之和。 饱和湿度不是固定不变的,饱和湿度随温度的上升而增大,温 度越高,单位体积中所能容纳的水蒸气含量就越多,水汽压就越大, 直到达到饱和,此时饱和水汽压也增大到该温度下的最大值,多余的 水蒸气就会出现凝结现象。例如:20℃时饱和水汽压为17.12g/m3, 30℃时增大到30.04g/m3。饱和湿度与温度成正比。 3.相对湿度(relative humidity)在一定温度下,空气中实际含有 的水汽量与同温度下的空气最大水汽量之比的百分数,称为相对湿 度。即一定温度下绝对湿度占饱和湿度的百分比数。 相对湿度=绝对湿度/饱和湿度×100% 绝对湿度=饱和湿度×相对湿度 RH=(Pv/Pw)T×100% (2) 式中,Pv为空气水蒸气分压;Pw为空气温度T同温时水的饱 和水汽压。 相对湿度只表示空气离饱和的程度,不表示空气湿度的绝对大 小。例如,温度在10℃、15℃时,若相对湿度均为70%,其绝对湿 度是不同的,10°C时绝对湿度是6.45g/m3,15℃时为8. 95g/m3。 通常所说的相对湿度小,就表示空气距同温度下的饱和湿度远,空气 较干燥;相反就表示距离同温度下的饱和湿度近,空气较潮湿。某温

空气温湿度参数

相对湿度 相对湿度(Relative Humidity)。 空气有吸收水分的特征,湿度的概念是空气中含有水蒸气的多少。它有三种表示方法: 第一是绝对湿度,它表示每立方米空气中所含的水蒸气的量,单位是千克/立方米; 第二是含湿量,它表示每千克干空气所含有的水蒸气量,单位是千克/千克·干空气; 第三是相对湿度,表示空气中的绝对湿度与同温度下的饱和绝对湿度的比值,得数是一个百分比。(也就是指在一定时间内,某处空气中所含水汽量与该气温下饱和水汽量的百分比。) 相对湿度用RH表示。相对湿度的定义是单位体积空气内实际所含的水气密度(用d1 表示)和同温度下饱和水气密度(用d2 表示)的百分比,即RH(%)= d1/ d2 x 100%;另一种计算方法是:实际的空气水气压强(用p1 表示)和同温度下饱和水气压强(用p2表示)的百分比,即RH(%)= p1/ p2 x 100%。 干球温度:指温度计测得的空气温度,常采用摄氏温度。在老式医疗用的温湿度计(现在CCTC 一厂还有在使用)左边那条温度计实测的温度即干球温度。 湿球温度:指湿球温度计测得的温度,常采用摄氏温度。在老式医疗用的湿温度计右边的那条温度计上面就写着湿球温度。可以发现它的构造,是在温度计的感温球包绕上一层棉纱,棉纱引到下面的水槽里,水槽注满水,水被棉纱吸上来包围着温度计的感湿球。水在常温下蒸发必须有外界的热能支持才能进行,热能的供给速度和水蒸发的速度达到一个稳定的平衡,而在这个平衡界面的湿度就是湿球温度。这湿球温度的大小将反映出空气相对湿度的大小。 温湿计:最原始的温湿计就像是老式医疗用的那种温湿度计,测定干球温度,然后与湿球温度比较差度,在刻度盘中查出现在实际的相对湿度的值,来得知现在空气的湿度状态。这刻度盘中的数据来自被誉为“空调之父”的美国人开利研制出的空气焓湿图。现在大部分采用特种感温感湿材料制成的温湿计,有的更加上机械旋转装置构成温湿自动记录仪,现在CCTC 普遍使用这种温湿记录仪。 绝对湿度 绝对湿度" 英文对照:absolute humidity; 1、绝对湿度是指每单位容积的气体所含水分的重量一般用mg/L作指标.相对湿度是指绝对湿度与该湿度饱和状态水蒸气含量之比用百分数表达. 2、绝对湿度是指单位体积的空气中含有水蒸汽重量的实际数值.饱和温度是指在一定的气压和一定的温度的条件下、单位体积的空气巾能够含有水蒸汽的极限数值. 3、绝对湿度是指在一定温度时,单位体积的空气中所含水蒸气的份量(gm.),相对湿度是指在一定温度时,空气中的实际水蒸气含量与饱和值之比,用百分比表示. 4、水汽含量是指一定体积空气内的水分总量,如水汽密度就是这些量值中的一个称为绝对湿度.相对湿度是空气样本内实际水汽含量与同温度下、同体积的饱和空气的水汽含量的百分比,是可直接观测的最普通的湿度量值. 5、在气体混合物单位体积中所含的水蒸气量称为绝对湿度.相对湿度是指在某个温度下,绝对湿度与完全饱和水蒸气最大湿度的比值,用百分数(%)来表示. 6、绝对湿度是指1立方米的空气呈水蒸气状态下的含水克数.1立方米空气所能吸收水蒸气的最大量叫作最大湿度或饱和点最大湿度很大程度上取决于温度.

硅藻泥施工方案

6.1施工准备 (1)技术准备 1)编制墙面硅藻泥施工方案,并对工人进行书面技术及安全交底。 2)施工前应组织进行样板施工,样板经确认后方可进行大面积施工。(2)材料准备 1)硅藻泥:符合设计要求的硅藻泥,应有产品合格证及检测报告、产 品说明书、环保指标达到国家有关标准。 2)基层腻子:采用耐水腻子粉。 3)界面剂:采用界面剂。 (3)施工机具 脚手架、小铁锹、擦布、开刀、胶皮刮板、钢片刮板、腻子托板、扫帚、小桶、大桶、排笔、刷子 (4)施工作业条件 1)保证基面平整、密实、清洁,含水率小于10%,PH值小于10,阴阳 角及线条横平坚直;基层的偏差应小于2mm。 2)抹灰作业全部完成,过墙的管道、洞口、阴阳角等处应提前抹灰找 平修整,并充分干燥。 3)将混凝土过梁、梁垫、圈梁、混凝土柱、梁等表面突出部分剔平, 将蜂窝、麻面、露筋、疏松部分剔到实处,并刷胶粘性素水泥或界面剂。 然后用1:3的水泥砂浆分层抹平。脚手眼和废气的孔洞应堵严,外露钢筋头、铅丝头及木头等要剔除并做防锈处理,窗台砖补齐,墙与楼板、梁底等交接处应用斜砖砌严补齐。 4)硅藻泥施工前应熟悉图纸、设计说明及其他设计文件,制定方案, 做好样板间,经检验达到要求标准后方可正式施工。 5)腻子前应先搭好脚手架或准备好高马凳,架子应离开墙面20~ 25cm,便于操作。 6)做好样板间,并经检查鉴定合格后,方可组织大面积施工。 6.2施工工艺 (1)施工工艺流程 墙面清理→底层腻子→基层腻子打磨→第一遍硅藻泥→第二遍硅藻泥→硅藻

泥图案制作→成品保护→验收 (2)基层腻子施工 1)清理墙面:先将墙面灰尘、浆粒清理干净,用石膏将墙面磕碰处及坑洼缝隙等找平,干燥后用砂纸将凸出处磨掉,将浮尘扫净。对于硅钙板墙面,要先将硅钙板接缝处进行嵌缝处理。 不同材料交接处用的确良布,宽度不小于100mm。 对于结构偏差较大的部位,应采用底层+面层粉刷石膏,每层厚度不得超过4mm,待干燥后再进行下一遍。平整度达到要求后,再进行腻子施工。 参考用胶量:0.4~0.6kg/m2 2)耐水腻子准备调配:按照耐水腻子粉:水=1:0.4~0.5的比例大致搅拌均匀,放置10~30分钟后,再次充分搅拌均匀即可使用。 3)刮耐水腻子:墙面耐水腻子的遍数可由墙面平整程度决定,一般情况为三遍。第一遍用胶皮刮板横向满刮,一刮板紧接着一刮板,接头不得留茬,每刮一板最后收头要干净利落。干燥后磨砂纸,将浮腻子及斑迹磨光,再将墙面清扫干净。第二遍用胶皮刮板竖向满刮,所用材料及方法同第一遍腻子,干燥后砂纸磨平并清扫干净。第三遍用胶皮刮板找补腻子或用钢片刮板满刮腻子,将墙面刮平刮光,干燥后用细砂纸磨光,不得遗漏或将腻子磨穿。每遍腻子厚度不宜过大,刮头遍腻子找平时,腻子厚度为0.5~0.8mm要均匀平整。厚度不应大于2mm,一般为1~2mm。 腻子以刮实压光为主,刮实均匀,有光滑效果,对于结痕和不平处,用砂纸打磨。 (3)硅藻泥面层施工施工 1)首先根据施工量准备清水,在搅拌容器中加入施工用水量90%的清水,然后倒入康力硅藻泥干粉浸泡,浸泡后用电动搅拌机搅拌约20分钟,搅拌同时加入另外10%的清水,充分搅拌均匀后方可使用。加水搅拌后的产品最好当天使用完毕。 在专业技术人员根据现场气候条件制定硅藻土配方,按厂家提供的方法在原材料中按比例加入清水,并现场搅拌一定时间,让混合物充分溶解、反应完全; 现场搅拌方法: a.在大容器内先倒9成清水,然后倒入硅藻泥粉体。

相关文档
最新文档