开题报告(暖通空调专业中央空调系统毕业设计)

开题报告(暖通空调专业中央空调系统毕业设计)
开题报告(暖通空调专业中央空调系统毕业设计)

毕业论文开题报告

论文题目:宾馆空调系统设计

专业:热能与动力工程

学生姓名:xxx

指导教师:xxx

日期:2012年4月2日

暖通空调设计毕业设计说明书

摘要 本设计为哈尔滨望江集团办公楼空调系统工程设计。哈尔滨望江集团办公楼属中小型办公建筑,本建筑总建筑面积4138m2,空调面积2833m2。地下一层,地上八层,建筑高度33.9m。全楼冷负荷为191千瓦,全楼采用水冷机组进行集中供给空调方式。 此设计中的建筑主要房间为办公室,大多面积较小,且各房间互不连通,应使所选空调系统能够实现对各个房间的独立控制,综合考虑各方面因素,确定选用风机盘管加新风系统。在房间内布置吊顶的风机盘管,采用暗装的形式。将该集中系统设为风机盘管加独立新风系统,新风机组从室外引入新风处理到室内空气焓值,不承担室内负荷。风机盘管承担室内全部冷负荷及部分的新风湿负荷。风机盘管加独立新风系统由百叶风口下送和侧送。水系统采用闭式双管同程式,冷水泵三台,两用一备;冷却水泵选三台,两用一备。 在冷负荷计算的基础上完成主机和风机盘管的选型,并通过风量、水量的计算确定风管路和水管路的规格,并校核最不利环路的阻力和压头用以确定新风机和水泵。 依据相关的空调设计手册所提供的参数,进一步完成新风机组、水泵、热水机组等的选型,从而将其反应在图纸上,最终完成整个空调系统设计。 关键词:风机盘管加独立新风系统;负荷;管路设计;制冷机组:冷水机组

Abstract The design for the Harbin Wangjiang Design Group office building air conditioning system. Harbin Wangjiang Group is a small and medium-sized office building office buildings, the total floor area of building is 4138m2, air-conditioned area is 2833m2. There are eight floor of the building, building height is 33.9m. Cooling load for the entire floor, 191 kilowatts, the whole floor using Central Cooling Chillers to focus on the way . This design of the main room of the building for office, most of them is very small, and the rooms are not connected, the selected air-conditioning system should be able to achieve independent control of each room, considering the various factors to determine the selection of fan-coil plus fresh air system. Arrangement in the room ceiling fan coil units, using the dark form of equipment. Set the focus on fan-coil system, plus an independent air system, fresh air from the outdoor unit to deal with the introduction of a new wind to the indoor air enthalpy value, do not bear the load of indoor. All bear the indoor fan-coil cooling load and part of its new rheumatoid load. Fan-coil plus an independent air system sent by the Venetian and the under side air delivery. Closed water system with a dual-track program, three cold-water pump, dual-use a prepared; cooling pumps three elections, one prepared by dual-use. In the cooling load calculation based on the completion of the selection of host and fan coil units, and air volume, the calculation of water, the wind pipe and water pipes to determine the specifications of the road and check the resistance to the most disadvantaged and the loop to determine the pressure head new fans and pumps. Based on the relevant manuals provided by air-conditioning design parameters, and further completion of the new air units, water pumps, hot water units, such as the selection, which will be reflected in their drawings, the final design of the entire air-conditioning system Key words: PAU+FCU systems; load; pipeline design; refrigeration machine; Chillers

暖通空调毕业设计

1.工程概况及主要设计参数 (1) 1.1 工程概况 (1) 1.2 基本设计参数 (1) 1.3 设计依据 (3) 2.空调系统的负荷计算 (3) 2.1空调房间的冷负荷计算 (3) 2.2湿负荷计算 (8) 2.3热负荷计算 (9) 3系统方案确定 (18) 3.1系统的分区 (18) 3.2空调系统的分类 (19) 3.3空调系统的比较 (20) 3.4空调系统方式的确定 (24) 3.4 空调房间送风量的确定 (27) 3.5空气处理设备选型 (29) 4.室内气流组织形式的确定及计算 (33) 4.1 送、回风口的型式 (33) 4.2 气流组织形式 (35) 4.3 气流组织的设计计算 (38) 5水系统设计 (44) 5.1水系统简介 (44) 5.2水系统的管路设计计算 (49) 5.4空调水系统水力计算 (51) 5.5系统管材的选择 (54) 6.风管的布置及其水力计算 (55) 6.1风管设计的基本知识 (55) 6.2风管的水力计算 (58) 7.空调制冷机房设计 (63) 7.1空调冷水系统 (63) 7.2热水循环系统.................................................................................. - 66 - 7.3冷冻水系统设计.............................................................................. - 68 - 7.4冷却水系统...................................................................................... - 71 - 7.5循环水系统的补水、定压与膨胀.................................................. - 74 - 7.6 管道的水力计算............................................................................. - 76 -8系统保温及消声、减震........................................................... - 79 - 8.1管道及设备的保温.......................................................................... - 79 -

暖通空调毕业设计开题报告

1.课程设计的意义 通过本次的课程设计,使自己拥有一定的暖通空调设计能力;了解一些相关的规范和条例;熟悉并掌握暖通空调设计流程;同时使自己的思维更加的严谨,态度更加的认真,为以后的社会工作奠定了扎实的基础。 2.文献综述 随着国民经济的快速持续发展,作为支柱产业之一的建筑业也得到迅猛发展。而作为建筑业的重要组成部份的暖通空调业,其新产品、新技术、新材料更是层出不穷。暖通空调业发展所遵循的原则,概括起来就是:节能、环保、可持续发展,保证建筑环境的卫生与安全,适应国家的能源结构调整战略,贯彻热、冷计量政策,创造不同地域特点的暖通空调发展技术。因此,如何结合设计的需要,重视相关技术,并有选择而合理的应用在我们的设计中,满足业主要求,提高设计水平,是我们必须努力做到的。 2.1.暖通空调变工况点优化控制及能量管理探讨 2.1.1.工况点优化控制 暖通空调变工况点优化控制问题的研究近年来在我国被重视。S.W.Wang 提出了一种基于整个系统环境的预测响应及能量运行来改变暖通空调系统控制,设定点的系统方法,并用遗传算法对系统进行优化控制,同时优化多个设定点来改善系统响应和降低系统能耗[1],后来他又采用自适应性控制理论对某海水冷却。空调系统进行了优化控制研究,采用带指数遗忘的最小二乘法参数辨识方法和基因遗传优化算法,对空调系统的空气处理单元进行了优化控制研究[2]。罗启军等人提出了一项动态的优化技术在一个指定期间内,能得到使目标函数( 运行成本或者峰值能耗) 最小的房间温度曲线,该算法还给出了暖通空调设备的最佳开/关时间[3]。K.T.Chan 等人提出用遗传算法对风冷制冷机的冷凝温度设定点进行优化控制以提高制冷机的效率[4]。此外,有许多研究者用人工神经网络来模拟暖通空调系统中各个设备的非线性特性,用于实现对整个空调系统的优化控制。目前,研究者们将更多先进的建模方法和智能优化方法引入到了暖通空调的优化控制中,更加注重变工况点的在线优化控制。何厚建等人对已建的暖通空调各关键设备的静态模型采用用实数编码的遗传算法建立了水系统工作点优化控制策略[5]杨晓平等人采用模糊聚类和RBF方法建立了空气处理单元的动态数学模型,以最终舒适性为目标优化空气处理单元的温湿度和送风压力[6]。孙一坚根据空调负荷变化对一级泵水系统进行变流量控制,取得了显著效果[7]。总之国内的学者更多探讨的是把智能方法引入控制系统的优化中,仿真研究多,实践成果少。

中央空调毕业设计开题报告

毕业设计(论文)开题报告 课题名称: 学院:船舶与建筑工程学院 专业:建筑环境与设备工程 年级: A08建环(1)班 指导教师: 学生:铁君 学号:____ 起迄日期:______ 2011年月日

毕业设计(论文)开题报告 一、综述本课题国外研究动态,说明选题的依据和意义 随着我国经济的逐步增长,居住条件日益改善,人们对生活环境的舒适性的要求越来越高,对中央空调的需求越来越大,家用空调从奢侈品变成了舒适家居的不可缺少的重要部分。 中国的国情与美国和日本都有很大的不同,因此,在发展家用小型中央空调的道路上,应当结合中国自身的特点,在仔细分析中国具体国情的基础上,推进我国在中央空调领域中的研究和应用。 第一,我国是一个幅员辽阔的国家,地理、气候条件极为复杂,拥有多种多样的气候类型。这就必然要求我们的中央空调具有多样性的特点。如何根据不同的气候特征选择合适的空调型式,如何在系统设计中充分考虑不同气候的影响,这是我们在发展中央空调时应当考虑的问题。 第二,我国经济发展水平地区差异性大,在不同的地区人们对空调的需求不一样。即使在同一地区,由于人们的收入水平不一样,住宅形式也千差万别,而且生活习惯也不尽相同,因此对空调的需求也是多层次的。如何针对不同层次的用户设计不同型式的空调,这也是值得研究的一个问题。 第三,从能源的角度来看,我国虽然能源总量很大,但由于人口众多,人均能源拥有量不高,能源供应相对较为紧。而住宅空调在当前的能源消耗结构中所占的比重是非常大的。这就要求我国的小型中央空调的发展必需注重节能性,一方面要注重提高机组本身的能效比,另外一方面应当注重能源的综合利用。这样也就对变流量技术、蓄能技术、能源综合利用技术等提出了更高的要求。 第四,从环境的角度来看,目前我国环境污染的问题较为突出,许多城市出现了诸如“热岛效应”、空气污染等现象。考虑上述问题,一方面是要求所开发的小型中央空调必须具有环保的特点,把对环境的影响尽量减小到最小,另一方面是要充分考虑到环境污染对空调系统本身的性能带来的影响,针对它进行一些相应的设计。例如,在使用风冷热泵作为室外主机时,目前我国大城市中污染较为严重的空气对机组换热性能的影响就应当充分考虑。 通过以上分析可以看出,我国对中央空调的需多样化、多层次的,因此我们对小型

2021年暖通空调毕业设计开题报告模板

暖通空调毕业设计开题报告模板 暖通空调毕业设计开题报告模板 无论是课题的,还是的写作,都是与开题报告密切相关的,今 天带来一篇暖通空调毕业设计开题报告,希望给大家提供一定的帮助。 通过本次的课程设计,使自己拥有一定的暖通空调设计能力; 了解一些相关的规范和条例;熟悉并掌握暖通空调设计流程;同时使 自己的思维更加的严谨,态度更加的认真,为以后的社会工作奠定了扎实的基础。 随着国民经济的快速持续发展,作为支柱产业之一的建筑业也 得到迅猛发展。而作为建筑业的重要组成部份的暖通空调业,其新产品、新技术、新材料更是层出不穷。暖通空调业发展所遵循的原则,概括起来就是:节能、环保、可持续发展,保证建筑环境的卫生与安全,适应国家的能源结构调整战略,贯彻热、冷计量政策,创造不同地域特点的暖通空调发展技术。因此,如何结合设计的需要,重视相关技术,并有选择而合理的应用在我们的设计中,满足业主要求,提高设计水平,是我们必须努力做到的。 暖通空调变工况点优化控制问题的研究近年来在我国被重视。S.W.Wang 提出了一种基于整个系统环境的预测响应及能量运行来改

变暖通空调系统控制,设定点的系统方法,并用遗传算法对系统进行优化控制,同时优化多个设定点来改善系统响应和降低系统能耗???,后来他又采用自适应性控制理论对某海水冷却。空调系统进行了优化控制研究,采用带指数遗忘的最小二乘法参数辨识方法和基因遗传优化算法,对空调系统的空气处理单元进行了优化控制研究???。罗启军等人提出了一项动态的优化技术在一个指定期间内,能得到使目标函数( 运行成本或者峰值能耗) 最小的房间温度曲线,该算法还给出了暖通空调设备的最佳开/关时间???。K.T.Chan 等人提出用遗传算法对风冷制冷机的冷凝温度设定点进行优化控制以提高制冷机的效率???。此外,有许多研究者用人工神经网络来模拟暖通空调系统中各个设备的非线性特性,用于实现对整个空调系统的优化控制。目前,研究者们将更多先进的建模方法和智能优化方法引入到了暖通空调 的优化控制中,更加注重变工况点的在线优化控制。何厚建等人对已建的暖通空调各关键设备的静态模型采用用实数编码的遗传算法建 立了水系统工作点优化控制策略???杨晓平等人采用模糊聚类和RBF 方法建立了空气处理单元的动态数学模型,以最终舒适性为目标优化空气处理单元的温湿度和送风压力???。孙一坚根据空调负荷变化对一级泵水系统进行变流量控制,取得了显著效果???。总之国内的学者更多探讨的是把智能方法引入控制系统的优化中,仿真研究多,实践成果少。

暖通空调毕业设计(论文)任务书

毕业设计(论文)任务书 毕业设计(论文)题目:某市某综合楼空调系统设计 系别能源与动力学院班级建环本121/122 学生姓名学号 指导教师职称 毕业设计(论文)进行地点:校内 任务下达时间: 2015年 12 月 24 日 起止日期:2016年 3 月1日起——至 2016年 6 月日止 教研室主任年月日批准 1、论文的原始资料及依据:

(一)题目来源:某市某综合楼建筑结构图 (二)设计主要技术参数 (1)土建资料 详见建筑图纸。 (2) 气象参数:根据本市的气象资料确定; (3)建筑参数: 外墙体结构:根据地区自行选定,如δ=370 m m红砖,内外抹灰20mm 屋面:根据地区自行选定,如200mm厚混凝土板加12.5mm厚加气混凝土保温层。 外窗:根据地区自行选定,如标准玻璃的单层钢窗,全部挂淡色窗帘,(4)室内空调设计参数:温度t n=26℃; 湿度φn=60%; 风速不大于0.3 m/s。 (5)照明容量: 40W/m2 (6)房间人数:0.5人/m2,群集系数0.92 (三)设计主要技术关键 正确进行空调负荷和新风量的计算,确定出冷气方案,合理地布置管道,并进行水力计算,合理选择及布置设备,做好气流组织。 2、设计(论文)主要内容及要求 通过本次设计使学生系统地掌握空调系统设计的主要方法和步骤,能根据实际情况合理确定空调方案,会计算空调系统的负荷量和新风负荷量,能合理布置管道和设备,了解空调设备的型式及用途,会进行设备的选型,合理进行气流组织,会计算水管、风道的阻力,选取水泵、风机等。使学生能把所学知识灵活运用到实际当中去,让理论与实际相结合,为学生毕业以后的工作打下坚实基础。 主要内容: 空调系统的设计 (1)、由建筑物所在地区确定室内外气象参数; 夏季室内外设计计算参数;室内温度、湿度、风速、新风量等参数。

暖通毕业设计开题报告

暖通毕业设计开题报告 Document serial number【KKGB-LBS98YT-BS8CB-BSUT-BST108】

毕业设计(论文)开题报告 题目:永州商业广场综合楼中央空调系统设计 学院:建筑工程学院 专业:建筑环境与设备工程 学生姓名: xx 学号: 14 指导老师: xxx 2016年 3月 30日 开题报告填写要求 1.开题报告(含“文献综述”)作为毕业设计(论文)答 辩委员会对学生答辩资格审查的依据材料之一。此报告应在指 导教师指导下,由学生在毕业设计(论文)工作前期内完成, 经指导教师签署意见及所在专业审查后生效。 2.开题报告内容必须用黑墨水笔工整书写或按此电子文档 标准格式(可从教务处网页上下载)打印,禁止打印在其它纸 上后剪贴,完成后应及时交给指导教师签署意见。 3.“文献综述”应按论文的格式成文,并直接书写(或打 印)在本开题报告第一栏目内,学生写文献综述的参考文献应 不少于10篇(不包括辞典、手册),其中至少应包括1篇外文 资料;对于重要的参考文献应附原件复印件,作为附件装订在 开题报告的最后。 4.统一用A4纸,并装订单独成册,随《毕业设计(论 文)说明书》等资料装入文件袋中。 毕业设计(论文)开题报告

3、冰蓄冷中央空调 冰蓄冷中央空调是由冰提供冷源的中央空调系统,相对于常规中央空调增加一个蓄冰装置。冰蓄冷中央空调可以减缓用电高峰紧张,而且比常规空调系统每年节约运行费用10%-30%。 目前世界发达国家都已经或正在使用冰蓄冷空调,我国目前实施推广的省、市有北京、湖北、河南、湖南、江苏、浙江、广东等,尤其是在以广东为中心的华南地区,每年使用中央空调的时间长达9-10个月,使用冰蓄冷空调无论在经济效益上,还是社会效益上,意义更为重大。 四、中央空调的发展趋势 中央空调系统有三种主要形式: 中央空调是集中处理空调负荷的系统型式,其冷/热量是通过一定的介质输送到空调房间里去的。按照家用小型中央空调的输送介质的不同,常见的家用小型中央空调可以分成以下三种主要型式。 风管式系统:风管式系统以空气为输送介质,其原理与大型全空气中央空调系统的原理基本相同,是一个小型化的全空气中央空调系统。它利用室外主机集中产生冷/热量,将从室内引回的回风进行冷却/加热处理后,再送入室内消除其空调冷/热负荷。相对于其它的家用小型中央空调型式,风管式系统初投资较小。如若引入新风,其空气品质能得到较大的改善。但风管式系统的空气输配系统所占用建筑物空间较大,一般要求住宅要有较大的层高。而且它采用统一送风的方式,在没有变风量末端的情况下,难以满足不同房间不同的空调负荷要求。而变风量末端的引入将会使整个空调系统的初投资大大增加。 冷/热水机组:冷/热水机组的输送介质通常为水或乙二醇溶液,它的基本原理与通常所说的风机盘管系统类似。通过室外主机产生出空调冷/热水,由管路系统输送至室内的各末端装置,在末端装置处冷/热水与室内空气进行热量交换,产生出冷/热风,从而消除房间空调负荷。它是一种集中产生冷/热量,但分散处理各房间负荷的空调系统型式。该系统的室内末端装置通常为风机盘管。目前风机盘管一般均可以调节其风机转速,从而调节送入室内的冷/热量,因此该系统可以对每个空调房间进行单独调节,满足不同房间不同的空调需求,同时其节能性也较好。此外,由于冷/热水机组的输配系统所占空间很小,因此一般不受住宅层高的限制。但此种系统一般难以引进新风,因此对于通常密闭的空调房间而言,其舒适性较差。

暖通空调专业-毕业设计外文翻译

Refrigeration System Performance using Liquid-Suction Heat Exchangers S. A. Klein, D. T. Reindl, and K. BroWnell College of Engineering University of Wisconsin - Madison Abstract Heat transfer devices are provided in many refrigeration systems to exchange energy betWeen the cool gaseous refrigerant leaving the evaporator and Warm liquid refrigerant exiting the condenser. These liquid-suction or suction-line heat exchangers can, in some cases, yield improved system performance While in other cases they degrade system performance. Although previous researchers have investigated performance of liquid-suction heat exchangers, this study can be distinguished from the previous studies in three Ways. First, this paper identifies a neW dimensionless group to correlate performance impacts attributable to liquid-suction heat exchangers. Second, the paper extends previous analyses to include neW refrigerants. Third, the analysis includes the impact of pressure drops through the liquid-suction heat exchanger on system performance. It is shoWn that reliance on simplified analysis techniques can lead to inaccurate conclusions regarding the impact of liquid-suction heat exchangers on refrigeration system performance. From detailed analyses, it can be concluded that liquid-suction heat exchangers that have a minimal pressure loss on the loW pressure side are useful for systems using R507A, R134a, R12, R404A, R290, R407C, R600, and R410A. The liquid-suction heat exchanger is detrimental to system performance in systems using R22, R32, and R717. Introduction Liquid-suction heat exchangers are commonly installed in refrigeration systems With the intent of ensuring proper system operation and increasing system performance.Specifically, ASHRAE(1998) states that liquid-suction heat exchangers are effective in: 1) increasing the system performance 2) subcooling liquid refrigerant to prevent flash gas formation at inlets to expansion devices 3) fully evaporating any residual liquid that may remain in the liquid-suction prior to reaching the compressor(s) Figure 1 illustrates a simple direct-expansion vapor compression refrigeration system utilizing a liquid-suction heat exchanger. In this configuration, high temperature liquid leaving the heat rejection device (an evaporative condenser in this case) is subcooled prior to being throttled to the evaporator pressure by an expansion device such as a thermostatic expansion valve. The sink for subcooling

毕业设计开题报告及文献综述

毕业设计开题报告及 文献综述 Revised on November 25, 2020

华北电力大学 毕业设计(论文)开题报告 学生姓名:宗均恺班级:建环13K2 所在院系:动力工程系 所在专业:建筑环境与能源应用工程 设计(论文)题目:石家庄某接待中心中央空调系统设计指导教师:刘志坚 2017年 3月 5 日 毕业设计(论文)开题报告

保定某中型商场暖通空调系统设计 1 选题背景及意义 暖通空调(HVAC)技术发展概况和前景[8] 建筑是人们生活与工作的场所。现代人类大约有五分之四的时间在建筑中度过。人们已经逐渐认识到,建筑对人类寿命、工作效率、产品质量起到极为重要的作用。人类在从穴居到居住现代环境的漫长发展道路上,始终不懈的改善室内环境,以满足人类自身生活、工作对环境的要求和生产、科学实验对环境的要求。人们对建筑的要求不只有挡风遮雨的功能,而且还应是一个温湿度怡人、空气清新、光照柔和、宁静舒适分环境。生产与科学是经验对环境提出了更为严苛的条件,如计算室或标准量具生产环境要求温度恒定,纺织车间要求湿度恒定,有些合成纤维的生产要求恒温恒湿,半导体期间、磁头、磁鼓生产要求对环境的灰尘有严格的控制,抗菌素生产与分装、大输液生产、无菌试

验动物饲养等要求无菌环境,等等。这些人类自身对环境的要求和生产、科学实验对环境的要求导致了建筑环境的控制计术的产生与发展,并且已形成了一门独立的学科。建筑按环境学指出,建筑环境由热湿环境、室内空气品质、室内光环境和声环境组成。采暖通风与空气调节是控制建筑热湿环境和室内空气品质的技术,同时也包含对系统本身所产生的噪声的控制。 随着时代的发展,人们对生产生活的建筑环境提出了越来越高的要求,同时由于能源紧缺,环境污染严重等问题也对建筑提出了节能减排的要求。等等这些问题就要求我们暖通人把握自身专业,顺应潮流发展,在未来利用所学成就自我成就暖通这个行业。 现代中大型接待中心的空调设计探讨 随着改革开放及经济建设的发展,我国商业建筑大量兴建,招待所、宾馆的数量也与日俱增。我国早期建起的招待所以及宾馆普遍存在着忽略室内环境品质或者夏季空调不足、能耗过大、室内空气品质差等问题。近年来,由于人们对居住品质的高要求以及旅游业的带动和宾馆产业的发展,大型宾馆,连锁旅店得到了迅速的发展,同时对宾馆环境提出了更高要求。 宾馆、酒店不同于商场等场所,它具有它自身的特点; 1)宾馆是由大厅和客房组成,由于大厅和多功能厅和客房的使用情况不同就对空调系统提出了不同的要求,要分别采用合适其特点的的系统和机组; 2)客房是个相对封闭的环境对新风要求比较高,需要不同于其他建筑的新风品质。 3)由于客房是居住环境以及宾馆品级,对室内温湿度要求比较严格。

关于地源热泵技术的毕业论文开题报告

关于地源热泵技术的毕业论文开题报告 一、选题的依据及意义: 1.依据: 进入90年代后,我国的居住环境和工业生产环境都已广泛地应用 热水供应装置,热水供应装置已成为现代学校居住必备。90年代中期,由于大中城市电力供应紧张,供电部门开始重视需求管理及削峰填谷,热泵供热技术提到了议事日程。近年来,由于能源结构的变化,促进 了地源热泵供热机组的快速发展。 随着生产和科技的不断发展,人类对地源热泵供热技术也进行了一 系列的改进,同时也在积极研究环保、节能的地源热泵供热产品和技术,现在利用成熟的电子技术来进行综合的控制,并和太阳能结合更注意 能源的综合利用、节能、保护环境及趋向自然的舒适环境必然是今后 发展的主题。 2.意义: 地源热泵技术,是利用地下的土壤、地表水、地下水温相对稳定 的特性,,通过消耗电能,在冬天把低位热源中的热量转移到需要供热 或加温的地方,在夏天还可以将室内的余热转移到低位热源中,达到降 温或制冷的目的。地源热泵不需要人工的冷热源,可以取代锅炉或市政 管网等传统的供暖方式和中央空调系统。冬季它代替锅炉从土壤、地 下水或者地表水中取热,向建筑物供暖;夏季它可以代替普通空调向土壤、地下水或者地表水放热给建筑物制冷。同时,它还可供应生活用水,可谓一举三得,是一种有效地利用能源的方式。通常根据热泵的热源(heatsource)和热汇(heatsink)(冷源)的不同,主要分成三类:空气源热泵系统(air-sourceheatpump)ashp 水源热泵系统(water-sourceheatpump)wshp 地源热泵系统(ground-sourceheatpump)gshp 平时还有人把热泵系统按照一次和二次介质的不同,分别叫做: 空气---水热泵系统 水---空气热泵系统

暖通空调开题报告

河北工程大学 建筑环境与设备工程专业毕业设计开题报告南京市某综合楼空调系统设计 学生姓名:李雪玉 学院:城建学院 专业:建筑环境与设备工程 班级: 11级03班 学号: 110220314 指导教师:张伟捷 2015年5月

1.工程概况 该建筑为南京市某综合办公楼楼,共11层。地下一层,地上十层,地下为停车厂、机房,地上一层为土地办证大厅,空间较大,五层有文体活动室,冷负荷较大,其余各层多为办公室,此综合办公楼建筑面积为17423㎡ , 其中空调面积9112㎡ ,高度46.8m 。该建筑的主要功能为办公用。 2.设计内容 2.1负荷计算 2.1.1 通过外围护结构传热形成的冷负荷 外围护结构冷负荷可按下式计算: )()()(R c c t t AK Q -=? ττ (2-1-1) 式中 K ——屋面或外墙传热系数W/( m 2 ·℃); A ——屋面或外墙面积。 )(τc t ——屋面的逐时冷负荷计算温度,℃; R t ——室内计算温度。 2.1.2外窗日射得热冷负荷 透过外窗的太阳辐射形成的冷负荷,按下式计算: ττn z g c J X AX Q =? )( (2-1-2) 式中 g X ——窗的构造修正系数。 z X ——内遮阳系数。 τn J ——计算时刻下透过有内遮阳设施窗玻璃太阳辐射的冷负荷强度,W/m 2。 2.1.3 外玻璃窗逐时传热形成的冷负荷 外窗传热形成的冷负荷,按下式计算: )()()(R c c t t aAK Q -=? ττ (2-1-3) 式中 a ——窗框修正系数; K ——窗玻璃的传热系数,; )(τc t ——计算时刻下的冷负荷温度。 2.1.4通过内围护结构传热形成的冷负荷

暖通毕业设计开题报告

题目:永州商业广场综合楼中央空调系统设计 学院:建筑工程学院 专业:建筑环境与设备工程 学生姓名: xx 学号: 201209010114 指导老师: xxx 2016年3月30日

开题报告填写要求 1.开题报告(含“文献综述”)作为毕业设计(论文)答辩委员会对学生答辩资格审查的依据材料之一。此报告应在指导教师指导下,由学生在毕业设计(论文)工作前期内完成,经指导教师签署意见及所在专业审查后生效。 2.开题报告内容必须用黑墨水笔工整书写或按此电子文档标准格式(可从教务处网页上下载)打印,禁止打印在其它纸上后剪贴,完成后应及时交给指导教师签署意见。 3.“文献综述”应按论文的格式成文,并直接书写(或打印)在本开题报告第一栏目内,学生写文献综述的参考文献应不少于10篇(不包括辞典、手册),其中至少应包括1篇外文资料;对于重要的参考文献应附原件复印件,作为附件装订在开题报告的最后。 4.统一用A4纸,并装订单独成册,随《毕业设计(论文)说明书》等资料装入文件袋中。

毕业设计(论文)开题报告 文献综述 一、引言 随着我国人民生活水平的不断提高,购买力增强。近年来修建了不少商业建筑,并且向多元化方向发展,建筑规模越来越大。装饰豪华、营销全面、多维服务,集商贸、娱乐、居住、办公为一体的高级商城也层出不穷。 商业建筑是一个流动人口众多的公共场所,室内空气的温湿度、洁净度和新鲜空气量等,对顾客和商场职工的身体健康影响很大。因此,商业建筑的空气环境越来越被商业部门所重视。我国卫生防疫部门对商业建筑提出了卫生要求,对较大的重点商场还进行过监测,对一些已建的大中商场要求进行改造,增设通风设施或加建空气调节装置。新建的大中商业建筑纷纷安装了空调系统,以提高商场的档次,吸引更多的顾客。各大城市中频频展开的“商战”更加速了空调系统在商业建筑中的普及。 商业建筑不断的增多,以及人们对室内空气的温湿度、洁净度和空气品质问题越来越重视,加上能源的紧缺,节能问题越来越引起人们的重视。因此迫切需要为商业建筑物安装配置节能、健康、舒适的中央空调系统来满足人们对高生活水平的追求。目前,随着我国经济的快速增长,生活条件日益改善,人们对生活环境的舒适性的要求越来越高,对中央空调的需求越来越大,对中央空调节能、舒适、健康更加关注。 国际标准规定,商用空调是3HP以上空调机组的统称,因此商用空调种类颇多。包括风冷热泵型中央空调机组,水冷螺杆式冷水机组、离心式冷水机组等等。 因此,设计一项节能、舒适、健康的中央空调工程是很有实际意义的。 二、研究现状 中央空调在世界上已有百年的发展历史,在中国也有20多年的应用时间,然而真正引起国内企业关注还是近几年。目前国内市场中央空调领域竞争已经进入白热化阶段,随着价格战连绵不断,在家用空调领域几乎已经无利可图的企业纷纷开始在中央空调领域寻找新的发展空间和利润增长点。 2003年中央空调市场容量将达到85亿元,2005年达到200亿元以上。市场空间迅

暖通空调毕业设计(论文)任务书解答

毕业设计(论文)任务书 毕业设计(论文)题目:某市某综合楼空调系统设计 系别能源与动力学院班级建环本121/122 学生姓名___________________ 学号 ________________________ 指导教师________ 职称_______________________ 毕业设计(论文)进行地点:校内 _______________________ 任务下达时间:2015 年12 月24 日 起止日期:2016年3月1日起——至2016年6月日止 教研室主任_________________ 年月日批准 1、论文的原始资料及依据:

(一)题目来源:某市某综合楼建筑结构图 (二)设计主要技术参数 (1)土建资料 详见建筑图纸。 (2 )气象参数:根据本市的气象资料确定; (3 )建筑参数: 外墙体结构:根据地区自行选定,如S =370 m m红砖,内外抹灰20mm 屋面:根 据地区自行选定,如200mm 厚混凝土板加12.5mm 厚加气混凝土保温层。 外窗:根据地区自行选定,如标准玻璃的单层钢窗,全部挂淡色窗帘,(4)室内空调设计参数:温度t n=26C; 湿度? n=60% 风速不大于0.3 m/s 。 (5)照明容量:40W/m (6)房间人数:0.5人/m2,群集系数0.92 (三)设计主要技术关键 正确进行空调负荷和新风量的计算,确定出冷气方案,合理地布置管道,并进 行水力计算,合理选择及布置设备,做好气流组织。 2、设计(论文)主要内容及要求通过本次设计使学生系统地掌握空调系统设计的主 要方法和步骤,能根据实际情况合理确定空调方案,会计算空调系统的负荷量和新风负荷量,能合理布置管道和设备,了解空调设备的型式及用途,会进行设备的选型,合理进行气流组织,会计算水管、风道的阻力,选取水泵、风机等。使学生能把所学知识灵活运用到实际当中去,让理论与实际相结合,为学生毕业以后的工作打下坚实基础。 主要内容: 空调系统的设计 1)、由建筑物所在地区确定室内外气象参数; 夏季室内外设计计算参数;室内温度、湿度、风速、新风量等参数。 (2)、空调房间热湿负荷计算;

XX毕业设计的开题报告两篇

XX毕业设计的开题报告两篇 1.课题名称: 钢筋混凝土多层、多跨框架软件开发 2.项目研究背景: 所要编写的结构程序是混凝土的框架结构的设计,建筑指各种房屋及其附属的构筑物。建筑结构是在建筑中,由若干构件,即组成结构的单元如梁、板、柱等,连接而构成的能承受作用(或称荷载)的平面或空间体系。 编写算例使用建设部最新出台的《混凝土结构设计规范》GB50010-XX,该规范与原混凝土结构设计规范GBJ10-89相比,新增内容约占15%,有重大修订的内容约占35%,保持和基本保持原规范内容的部分约占50%,规范全面总结了原规范发布实施以来的实践经验,借鉴了国外先进标准技术。 3. 项目研究意义: 建筑中,结构是为建筑物提供安全可靠、经久耐用、节

能节材、满足建筑功能的一个重要组成部分,它与建筑材料、制品、施工的工业化水平密切相关,对发展新技术。新材料,提高机械化、自动化水平有着重要的促进作用。 由于结构计算牵扯的数学公式较多,并且所涉及的规范和标准很零碎。并且计算量非常之大,近年来,随着经济进一步发展,城市人口集中、用地紧张以及商业竞争的激烈化,更加剧了房屋设计的复杂性,许多多高层建筑不断的被建造。这些建筑无论从时间上还是从劳动量上,都客观的需要计算机程序的辅助设计。这样,结构软件开发就显得尤为重要。 一栋建筑的结构设计是否合理,主要取决于结构体系、结构布置、构件的截面尺寸、材料强度等级以及主要机构构造是否合理。这些问题已经正确解决,结构计算、施工图的绘制、则是另令人辛苦的具体程序设计工作了,因此原来在学校使用的手算方法,将被运用到具体的程序代码中去,精力就不仅集中在怎样利用所学的结构知识来设计出做法,还要想到如何把这些做法用代码来实现, 4.文献研究概况 在不同类型的结构设计中有些内容是一样的,做框架结

建筑暖通工程暖通毕业设计

建筑暖通工程暖通毕业设计 一、绪论 1.1我国暖通空调的现状及其发展 自从上世纪90 年代以来,空调已经广泛地应用于我国人民的居住 环境和工业生产环境中,空调技术已成为衡量建筑现代化水平的重要 标志之一。 90 年代中期,由于大中城市电力供应紧张,供电部门开始重视 需求管理及移峰填谷,把蓄冷空调技术提到了议事日程。近年来,由 于能源结构的变化,促进了吸收式冷热水机组的快速发展,以及热泵 技术在长江中下游地区的应用。随着生产和科技的不断发展,人类对空 调技术也进行了一系列的改进,同时也在积极研究环保、节能的空调产 品和技术,已经投入使用了冰蓄冷空调系统、燃气空调、VAV 空调系统、地源热泵系统等。暖通空调技术的发展,必然会受到能源、环境条 件的制约,所以能源的综合利用、节能、保护环境及趋向自然的舒适 环境必然是今后发展的主题。 1.2建筑空调系统节能国内外研究现状 1.2.1建筑空调建筑空调系统节能国外研究现状 能源是整个经济系统的基本组成部份,作为一个能源消耗大国,美国在节能和提高能源利用率方面投入了大量的人力、物力。在美国 的整个能源消耗中,有约1/3 以上消耗在建筑能耗上,这些能耗用来 满足人们的热舒适、空气品质、提高人们的生活质量。美国暖通空调 制冷工程师协会、美国制协会、美国冷却塔协会等组织、美国能源部以 及众多暖通空调设备生产厂家如York, Carrier 等都为建筑节能 做ft了很大的贡献。特别是美国制冷设备生产厂商投入了大量的资源

研究高性能冷水机组,使得冷水机组单位制冷量的能耗仅为20 世纪70 年代的62.3%。美国在空调冷源水系统方面的研究也卓有成效,在冷却水系统方面着重于降低冷却水流量,以达到减少冷却水泵能耗的目的。日本是一个资源贫困的国家,其主要能源来自进口,同时又是一个能源高消费国家。因此,节能和提高能源的利用率对日本来讲有着重要的意义。长期以来,在建筑节能方面,日本做了大量工作,颁布了许多节能法规,提ft了建筑节能的评价方法。日本的一些设备生产厂家对空调和制冷设备的投入也很大。Daikin 公司首推的变频VRV 系统,为中小型建筑安装集中式空调系统创造了条件;Sany 公司则在直燃式冷水机组上成绩卓著。 世界各国大力发展可再生能源作为空调冷热源用能。地源热泵供暖空调是一种使用可再生能源的高效节能、环保型的工程系统。在美国地源热泵系统占整个空调系统的20%左右;瑞士40%的热泵为地祸热泵,瑞典65%的热泵为地祸热泵。 1.2.2建筑空调系统节能国内研究现状 我国是一个人均资源相对贫乏的国家,因此节能降耗有着十分重要的意义。近年来,由于国民经济的快速发展,使我国的能源显得越来越紧张。 (1)建筑空调系统节能国内研究现状概况 随着经济建设的不断深入和人们生活水平的不断提高,空调建筑物越来越多,建筑物消耗的能量也越来越大,甚至ft现了空调系统与 经济建设争抢电力资源的情况。因此,在建筑物节能显得十分迫切。在我国建筑总能耗中,空调系统的能耗占有相当大的比重,因此研究 探讨空调系统的节能就显得十分重要。在建筑物空调系统运行能耗中,

相关文档
最新文档