刚接柱脚锚栓计算
红色为输入值绿色为计算值黑色为结果值
底板长宽底板尺寸基础砼C30基础内力设计值L=h+2l1+2l2L=850mm fc=11.9N/mm^2M=116.06 B=b+2b1+2b2B=850mmβc=1√Ab/Al N=27.157 lt=70mm V=11.631
L/6141.6666667mm Q235锚栓抗拉强度设计值
L/6+lt/3165mm f t a140N/mm^2
偏心距e4273.667931mm E(钢材弹性模量)206000N/mm^2
E钢材/E砼n 6.866666667E(砼弹性模量)30000N/mm^2
受拉侧锚栓总有效面积A
e a2928mm2锚栓个数a6
刚接柱脚设计
3(e-L/2)11546.00379mm锚栓直径39mm 6nA e a/B(e+L/2-lt)656909.2655mm锚栓有效面积976mm^2
L-lt780mm 锚栓抗拉承
载力设计值136.6KN
公式1
变量x
n 计算单变量求值x
n
“工具”-单变量求值-4.03523E-05182.8759912
当e>L/6+lt/3
σc 2.249253144T a147.6601192
βc f c11.9A e a 1.054715137当L/6<e≤L/6+lt/3
σc-0.00553428T a0
βc f c11.9
当e≤L/6+lt/3
σc0.001206002T a0
βc f c11.9
底板下混凝土最大受压应力受拉侧锚栓总
拉力
水平抗剪承
载力
结果σc T a V fb
2.249253144147.660119269.92684768
βc f c T
a
/a(单个锚栓)V
11.9049.2200397411.63
判断满足满足满足见锚栓选用表
x n3+3(e-L/2)x n2-6nA e a/B(e+L/2-lt)(L-lt-x n)=0
σc=2N(e+L/2-lt)/Bx n(L-lt-x n/3)≤βc f c T a=N(e-L/2+x n/3)/(L-lt-x n/3) or A e a=T a/f t a V fb=0.4(N
σc=2N/3B(L/2-e)≤βc f c T a=0 V fb=0.4N≥V
σc=N/LB(1+6e/L)≤βc f c T a=0 V fb=0.4N≥V
输出
底板板厚
t pb≥√6M imax/f12.1931304mm
t pb≥√6N ta l ai/((D+2lai)f)39.93840829mm
根据支撑边选择
Mimax=M1 or Mimax=M2
or Mimax=M3 or
Mimax=M4 or Mimax=M5M
imax
5079.641325N.mm
Q235板厚16~40mm强度
设计值f205N/mm^2
单个锚栓所承受拉力N
ta
136600N
锚栓中心到底板支撑边
距离l
ai
77mm
锚栓直径D39mm
对悬臂板M
1
=σc a12/222676.9702N.mm
底板悬臂长度a
1
142mm
对三边支撑板和相邻两
边支撑板M
2
=ασc a225079.641325N.mm
板的自由边长度a
2
142mm
垂直于板自由边的支撑
边长度b
2150mm
输出
底板计算
b2/a2 1.056338028
根据表8-4选取α0.112
对四边支撑板M
=βσc a322494.466722N.mm
3
计算区隔内板的短边a
142mm
3
计算区隔内板的长边b
150mm
3
b3/a3 1.056338028
根据表8-5选取β0.055
对圆形周边支撑板M
4
=0.21σc r221732.62689N.mm 圆形板半径r214.5mm
对两对边支撑板M
5
=σc a52/812936.08743N.mm
两对边支撑板的跨度a
5214.5mm
V fb=0.4(N+T a)≥V
V fb69.92684768
V fb=0.4N≥V
V fb10.8628
V fb=0.4N≥V
V fb10.8628