矿山泄漏电缆通信系统的解决方案_王正祥

矿山泄漏电缆通信系统的解决方案_王正祥
矿山泄漏电缆通信系统的解决方案_王正祥

第35卷 2007年第10

162Mining & Processing Equipment

162

前 沿

第35卷 2007年第10

163

Mining & Processing Equipment

163前 沿

第35卷 2007年第10

164Mining & Processing Equipment

164

前 沿

Ventilator Malfunction Diagnosis….....YI Jiangang et al.(112-115) A kind of intelligent malfunction diagnosis approach based on fuzzy immune net clustering analysis was proposed in this paper to solve the problem that the prior information was needed in traditional malfunc-tion diagnosis. Compared with the other algorithms, this approach could overcome the problems of dynamic determination of classes and fuzzy border, was a better intelligent information processing al-gorithm without supervision. Finally, an application was proposed to prove the validity of the algorithm. 【Descriptors】 Fuzzy immune net Clustering analysis Malfunction diagnosis

Study and Control to Manufacturing Quality of RD Series Pla-netary Reducer….............................................LI Yin et al.(115-118) The paper detailedly analyzed the factors that affected manufacturing quality of RD series planetary reducer used for JT(K)YB-*×*XP hydraulic anti-explosion hoist and winch, revealed the possibility and feasibility to improve product quality, and narrated major parts about its manufacturing and assembly course on concrete operation detail, which could be reference at actually manufacturing this kind of re-ducer and has guidance sense for improving product quality.

【Descriptors】 Hoist Planetary reducer Quality control Analysis to

influential factor

Study to Dynamic Characteristic of a New Kind of Electronic-

Hydraulic Proportional Valve….........ZHU Jianxin et al.(118-121)

The paper introduced the structure and working principle of a kind of

foreign electronic-hydraulic proportional valve which is based on

twin valve insert control, and compared with the normal hydraulic

valve which is based on single valve insert control. Considering steady

hydraulic force, instantaneous hydraulic force, pre-compression of

spring, valve leakage and gravity, the paper established the mathe-

matical model of the valve and concluded the transfer function of the

system, applied MATLAB to make simulative study to valve dynamic

characteristic, obtained step response curve and the bode diagram.

The result shows that twin valve insert control is more effective and

flexible compared to single valve insert control of normal hydraulic

valve. On condition that the pre-compression of the spring located at

the end of the main valve insert and the gravity of the main valve

insert are ignored during analysis to dynamic characteristics, the valve

is of well responding speed and ideal bandwidth, and major factors

affects responding speed and bandwidth is flow gain of pilot valve

and elasticity coefficient of the spring located at the end of main valve

insert. 【Descriptors】 Electronic-hydraulic proportional valve Dy-

namic characteristic Twin valve insert Symmetry cylinder

Adjustment for Function Parameters of Transducer.........................….........................................................DANG Lihui et al.(122-125)

There are lots of function parameters in transducer, many parameter

keeps initial value at leave factory in factual application. However,

some parameters need to reset and adjust according to factual circum-

stance since they have much relationship with actual employment

circumstance. The paper introduced the adjustment approach with

SENLAN transducer. 【Descriptors】 Transducer Parameter Adjust-

ment

tion Analysis…................................YANG Fengwei et al.(144-145)

The paper described the potential safety trouble in power supply sys-

tem with 660V transformer and corresponding solution, and con-

ducted detailed discussion combining factual example. Meanwhile, it

also put forward the expectation towards relevant scientific and re-

search institute, hoping homemade MCCB with high-rupturing capac-

ity could be developed early. 【Descriptors】 660V power supply

Transformer Three-phase short-circuit current MCCB Rupturing

capacity

Design to Gas Density Detector Based on AVR Single-Chip

Processor…....................................LIU Zhengquan et al.(146-148)

Based on the analysis to cause of gas explosion, the paper suggested to

prevent this kind of accident by detecting gas density, and presented

the scheme for designing AT90S8535 gas density detector on the

basis of AVR single-chip processor. In this system, gas sensitive probe

and CH217 chip was applied to detect gas density in shaft, and accord-

ing to the output alarming signal and feedback voltage value of sensor

circuit, the single-chip processor control voice chip to report gas den-

sity every each fixed time and timely alarm at dangerous conditions.

LED numerical tube served as aid module to dynamically display gas

density in percent. While gas density collected by single-chip proces-

sor equal to preset data, it would be transferred to upper-position

processor by RS-485 to make synthetic analysis. 【Descriptors】 Gas

Density AVR single-chip processor CH217 chip ISD2560 voice chip

RS-485 bus

Synthetic Monitoring System Used in Shaft Spot Based on Zigbee…

...............…...........................................YANG Xing et al.(149-151)

The paper offered a kind of wireless communication synthentic moni-

toring system used in shaft spot based on Zigbee and twin MCD

structure, analyzed the system about its systematic structure, hardware

configuration, interface circuit and working principle etc. The system

realized the collection of shaft surrounding parameters such as

temperature, humidity, density of gas, carbon monoxide and oxygen,

complicated calculation and long-distance wireless communication. It

proved reliable and real-time by experiment. 【Descriptors】 Moni-

tor Zigbee technique Twin MCU

Discussion to Energy Saving and Consumption Reduction of Active

Lime Rotary Kiln and Resource Synthetic Utilization……….........

..................................................................ZHANG Kaibo(152-154)

Initiated with guaranteeing continuous development of lime industry,

the paper analyzed the structure of major machine, burning unit and

gas handling system in burning system, narrated the resource such as

lime mine, gas with low heat capacity, dust and carbon dioxide, dis-

cussed the energy saving and consumption reduction of active lime

rotary kiln and approach for resource synthetic utilization, and of-

fered some suggustions.【Descriptors】 Lime industry Rotary kiln

Energy saving and consumption reduction Synthetic utilization Con-

….....

....................................................WANG Zhengxiang et al.(162-164)

The paper offered the solution scheme for leakage cable communica-

tion system, introduced leakage cable communication technique about

its basic theory and structural unit from voice communication, data

transmission and system for locating the identification card of person

and auto, analyzed solution scheme for each communication system

and systematic integration approach. 【Descriptors】 Leakage cable

Communication Solution scheme

Charcteristic and Technical Trouble of Pure Water Hydraulic Driv-

ing Technique…...........................CHAI Guangyuan et al.(167-168)

That pure water serving as media in hydraulic driving technique is

one of study direction, which is paid wide attention in domestic and

foreign hydraulic field in recent years. The paper detailedly discussed

pure water serving as media of hydraulic driving about its advantage

and some generally existed problems, summarized pure water hy-

draulic driving about its current study status and prospect at home and

abroad, and indicated its developing trend, application field and key

technique trouble. 【Descriptors】 Pure water hydraulic driving tech-

nique Driving media Key technical problem

泄漏电缆工作原理

泄漏电缆是泄漏同轴电缆的简称,是一种特制的同轴电缆。泄漏同轴电缆是一种在同轴电缆外导体纵长方向,以一定的间隔和不同形式开槽的特制同轴电缆。开槽的目的是为了使其电信号能量能从电缆槽口辐射出来,以达到向外传播和接收外来无线电波的目的,这种无线电波是开放式的,好比是为无线电波的进出洞开了一扇开放的“大门”。信号的能量通过泄漏电缆的长度来引导,有效区域同时受限于电缆内部和外部周边区域环境影响,这样使信号能够持续进入移动通信单元。a)竹节状b)螺旋状c)莲花状d)发泡状如常规的同轴电缆,信号的传输依赖于内部芯线和外部鞘之间的电压的不同。例如我们有意切断一个槽就可以阻断电流,电流不得不围绕这个槽,这样就引起了电缆内部电流磁场的变化,这样槽的作用就像一个耦合天线,并且会产生辐射,能量从电子波导中被泄漏。这种规则应用于建构波导中的槽天线,因此一个槽或一对槽的测量和描述经常使映射泄漏同轴电缆的方法:泄漏同轴电缆是可以考虑被用来制作耦合天线的。泄漏电缆根据所开槽的不同的方式,可分为辐射型和耦合型二种。a)辐射型泄漏电缆b)耦合型泄漏电缆辐射型泄漏电缆的外导体所开的槽呈周期性排列,辐射的形式类似沿着泄漏电缆轴向分布的一系列磁性偶极子的辐射,而且所有的槽都符合相位叠加原理,其中最典型的间距为所传送电磁波信号的半波长。耦合型泄漏电缆的外导体上一般有周期性的平行线的开槽,周期性开槽口将电缆内部传输的能量耦合出一部分,在电缆外部形成表面波,表面波的传播规律于在电缆到体内的传输导行波基本一致。而耦合型泄漏电缆雨辐

射型泄漏电缆的区别在于耦合型泄漏电缆所开槽的间距远远小于工作波长,所以在这种耦合方式下,电磁场通过槽衍射激发电磁场,由于趋肤效应,感应的谐振电荷只是沿着屏蔽导体的外表面运动,泄漏电缆就像一个长的陈列双极天线向外辐射的电磁波,耦合型泄漏电缆就像电子天线,整根泄漏电缆可以看成是一系列小天线的集合。a 耦合型泄漏电缆传输TE10模式电磁波的解剖图(实线为电力线,虚线为磁力线)b开槽处的电磁场耦合型泄漏电缆的结构如图所示,图b显示了电磁场在开槽处的畸变,产生了电偶极子。那么电偶极子是如何产生的呢?为了解释这个问题,先根据电磁转换的原理,分析与开槽孔相同大小的导体的情况,假设电荷沿导体做往复的简谐振动,一对电偶极子在一个往复的周期内产生一条向外发展的电场线,这样,偶极子在导体内以导体中心为中心点做简谐振动,最终形成向外辐射的一系列周期变化的同心电场线,根据互易性原理,在一面导体上开出同面积的槽孔的导体,会产生相对立的同心磁力线,这就是电场与磁场的互换。在近距离耦合的电磁波呈同心圆的结构,但如果远距离传输会受周围环境和衍射等因素的影响就比较大,电磁波向外发射就会受到干扰,空间传输距离就非常有限。

电力工程电缆施工方案模板

电力工程电缆施工 方案

一、工程概况 地点: XXXXXXX有限责任公司 二、施工前准备工作及必备条件 1、施工人员安排: 项目经理 1人 电工 5人 辅助工 10人 2、技术准备 2·1认真熟识、审核施工图纸, 领会设计意图, 严格按照图纸要求进行电缆敷设; 2·2电缆必须报经监理进行严格的检验, 合格后方可施工; 2·3针对工程情况, 对施工班组进行技术交底; 2·4根据工程实际情况划分施工流水段, 并以此为依据确定劳动力及材料需用量及施工人数; 3、施工人员必须具备的条件 3·1根据工程的实际需要培训操作工人, 特殊工种操作人员必须持证上岗。 3·2熟悉施工图纸及施工现场环境。 3·3对电缆知识应相当了解,具有敷设电缆的施工经验。4、机械、工具准备 4·1电缆敷设机、电缆支架及电缆轴、电缆滚轮、吊链、滑轮、尼龙绳、钢丝绳;

4·2皮尺、钢锯、气焊工具、电工工具; 4·3对讲机、绝缘摇表、万用表。 5、劳动力准备 5·1劳动力实行专业组织, 按不同施工部位来划分作业班组, 提高操作的熟练程度和劳动生关率, 以确保工程施工质量和施工进度。 5·2根据本工程阶段施工重点, 相应调配劳动力, 实行动态管 理。 5·3各施工人员必须接受建筑施工安全教育, 经考试合格后方可 上岗作业、未经建筑施工安全生产教育或考试不合格者, 严禁上 岗作业。 5·4每日上班前, 班组负责人必须集所辖全体人员, 针对当天任务, 结合安全技术交底内容和作业环境、设施、设备状况、本队人员 技术素质、安全意识、自我保护意识以及思想状态, 有针对性地 进行班前安全活动交底, 提出具体注意事项并跟踪落实, 做好活动 记录。 5·5严格按劳务用工政策法规进行施工用工管理。

漏泄同轴电缆的敷设施工工艺标准

漏泄同轴电缆的敷设施工工艺标准 1.施工准备 1.1 劳动组织 1.2 工机具

1.3 材料

2.操作程序 2.1 工艺流程 2.2 操作要点 2.2.1 施工准备 在施工准备阶段,详细调查隧道内漏缆挂设位置及电力线、回流

线的高度、侧别及安全距离是否能够满足布缆的设计要求,隧道外架挂区段地形情况,核实中继器、天线杆塔、接头的位置及中继段的长度。 2.2.2 单盘测试 包括编写盘号、核对规格型号及数量,外观检查及验气工作,环阻、绝缘电阻和电气绝缘强度的测试,稳气。 (1)电桥测量漏缆环阻 把漏缆一侧的外导体和内导体短接,另一侧用直流电桥测量其环阻,测试连接见下图。 其测试标准:应小于4Ω/Km。 (2)利用500V兆欧表对漏缆内外导体间的绝缘电阻进行测量,测试连接见下图。 其测试标准:应不低于1000MΩ·KM, (3)绝缘耐压 漏缆内外导体间的高压耐压标准是:工频3KV电压2分钟不击穿。

(4)单盘稳气 漏缆充气压不得大于100±10kpa;稳气气压为90—100kpa(24小时),利用热可缩帽进行封堵充气。 2.2.3 配盘 (1)根据设计文件及现场调查的实际情况,采用分级补偿的办法进行配盘。 (2)通过几种不同耦合损耗规格的漏缆(90dB,80dB,70dB,65dB)依次串联,用逐渐减小耦合损耗的办法来补偿由于漏缆传输损耗引起的电平下降,从而使列车在全线运行中能收到较平稳的信号电平。 (3)按照每种耦合损耗规格漏缆的长度,进行合理配置,最大限度的利用出厂单盘漏缆,尽量减少剩余短段漏缆和接头数目。 2.2.4 隧道内漏泄电缆的架挂 (1)隧道内电缆支架的安装 ①电缆支架孔的位置,距离钢轨面高度一般为4.8—4.9m. ②用冲击钻在洞壁预定位置钻一个Ф19mm的孔,孔深为70±3mm。孔应平直不可成喇叭状。 ③将胀管及螺杆装在一起放入Ф19mm孔内,用木锤打入洞内,要注意保护螺杆螺纹。 ④支架安装时,将垫圈螺母拧好固定,夹板固定要统一,以使电缆与洞壁之间的距离保持一致。 ⑤洞内吊夹每隔2.5—5m安装一个,如环境条件的影响,可做适当的调整。

2018年埋地泄漏电缆周界报警方案

埋地泄漏电缆周界报警系统 解 决 方 案 目录

1、系统概述 (2) 2、泄漏电缆报警器工作原理 (3) 3、泄漏电缆探测器组成 (3) 4、泄漏电缆报警器主要特点 (6) 5、泄漏电缆报警器主要技术参数 (7) 6、泄漏电缆报警系统拓扑图 (7) 7、泄漏电缆报警器的应用范围 (8) 8、与红外对射报警系统的比较 (8) 9、系统设备配置和预算........................................................................ 错误!未定义书签。 10、泄漏电缆报警器部分案例 (10) 11、部分案例图片欣赏 (11) 1、系统概述 泄漏电缆周界报警系统是一种隐蔽式的入侵探测报警,埋在周界围墙或铁艺围栏内的草坪下或

泥土下,不会破坏周围环境,不影响围界美观,人在不知觉的情况下,就会被探测到,是一种高科技的周界报警产品。 2、泄漏电缆报警器工作原理 泄漏电缆报警器工作时,通过一根泄漏电缆传送一定频率的射频电磁场,在泄漏电缆的外层导体开槽处,往外发射电磁场。另一根并行敷设的泄漏电缆接收电磁场,形成收发能量直接耦合,当入侵者进入两根泄漏电缆形成的电磁场探测区域时,电场能量受到扰动,引起接收信号的变化,这个变化的信号经放大处理后被检测出来,产生报警。 3、泄漏电缆探测器组成 泄漏电缆探测器由泄漏电缆探测器主机、非泄漏电缆、泄漏电缆、终端器以及电缆连接头组成。泄漏探测器主机的作用是发射和接收无线电磁场,并且分析处理接收信号,并按照智能算法判别报警与否,2根泄漏电缆埋在周界位置,1根发射电磁场,1根接收电磁场,2根非泄漏电缆连接探测

通信系统施工方案

通信系统施工方案批准: 审核: 编制: 某公司 某项目部 某年某月

通信系统施工方案 1 概述 1.1 工程概况 根据*市**工程总体要求,通信系统需要在输水管线施工时同期敷设1条GYTS-12B1光缆,光缆与管道同路由。根据本标段地质条件,采用地埋硅芯管道敷设。 本工程通信光缆线路路由服从输水管道线路路由,具体敷设方式为:硅芯管敷设在管道介质前进流向的左侧,埋深距地面1.2m,与输水管道水平间距1.5m。 1.2 主要工程量 本标段硅芯管铺设9.11km,详见表1-1。 表1-1 硅芯管配盘表 本标段光缆敷设*km,详见表1-2。 表1-2 光缆配盘表 2 编制依据

(1)《*市**工程通信系统施工图纸》及招标文件 (2)《水利水电工程通信设计规范》SL517-2013 (3)《通信线路工程设计规范》YD5102-2010 (4)《通信线路工程验收规范》YD5121-2010 3 硅芯管施工 3.1硅芯管沟开挖 管槽土方回填到管顶高程后,经测量放线(与输水管道水平间距1.5m位置)采用人工或60小反铲挖硅芯管沟槽,开挖深度约40cm,沟底宽度40cm。 3.2硅芯管敷设 沟底回填10cm细土或砂,找平压实后根据硅芯管配盘表的分段长度人工铺放硅芯管,然后铺填30cm细土后夯实。 硅芯管铺放过程中要及时检查硅芯管线型顺直,转角处曲率半径宜大于20倍的硅芯管外径,以保证光缆后期能顺利穿过。在硅芯管吹放和光缆接续的阀井硅芯管通过预留的刚性防水穿墙套管孔洞穿入;顶管段硅芯管施工时通过管道顶管施工时同时顶进的Φ60镀锌钢管中穿过;在硅芯管穿越公路、渠道时,硅芯管采用Φ50镀锌钢管保护。 4 光缆施工 4.1 光缆吹放示意图

低压电缆施工的解决方案.doc

低压电缆施工方案 一、低压电缆敷设施工准备 1、所采用的器材、材料应符合同家现行技术标准的规定,并应有产品合格证。 2、检查电缆:电缆不应有折叠、断裂及破损等缺陷,绝缘层表而应平整,光滑、色泽均匀,绝缘层厚度应符合规定。绝缘层应挤包紧密,且易剥离、电缆端部应有密封措施。 3、金具表面应光洁、无裂纹、毛刺、飞边、砂眼、气泡等缺陷,镀锌良好,镀锌层无剥落,锈蚀现象。 4、螺栓: 螺栓表面不应有裂纹、砂眼、锌皮剥落及锈蚀现象。螺杆与螺母的配合应良好。 5、主要机器具; 放线架、穿线器、活扳手、压线钳、手锤、钢锯、铁线、大小尼龙绳、等。 二、作业条件: 1、挖电缆沟:电缆沟深度70cm宽50cm。 2、电缆敷设方法:

方案1;使用穿管法,沟底浇筑10cm混凝土垫层,并排铺设两根穿电缆波纹管一备一用,穿电缆波纹管铺设完毕后浇筑25cm混凝土保护层,放线时通过其它线路的越线保护措施设置完毕。 方案2;直埋法,电缆沟挖好后沟底铺细土,将电缆敷设后用细土覆盖。 3、电缆: 方案1;铝芯电缆采用YJLV22¢120电缆217米、YJLV22¢95电缆350米、YJLV22¢35电缆130米. 方案2;铜芯电缆采用YJV22¢95电缆217米、YJV22¢70电缆350米、YJV22¢25电缆130米. 三、操作工艺 工艺流程: 放电缆→接线端子压接→室外低压电缆分接箱安装→低压搭火 (1)放电缆: 将电缆运到放线首端,用放线架架好线轴,将穿管器沿波纹管穿至放线首端,再将电缆与穿管器连接牢固,经行放电缆;放电缆过程中,应对电缆进行外观检查,不应发生磨伤、扭曲、等现象不应损伤

智能化泄漏电缆周界报警系统技术方案-2016

智能化泄漏电缆周界报警系统技术方案 2017年

目录 1.设计依据及其原则............................................ - 4 - 1.1设计依据及规范 .......................................... - 4 - 1.2设计原则 ................................................ - 4 - 2.系统设计分析................................................ - 4 - 2.1 系统功能分析............................................ - 4 - 2.2 系统结构分析............................................ - 5 - 3.设计方案详细说明............................................ - 5 - 3.1.1具体方案 .......................................... - 7 - 3.1.2前端铺设 .......................................... - 7 - 3.1.3信号回传 .......................................... - 8 - 3.2系统技术图 .............................................. - 8 - 3.3功能实现 ................................................ - 8 - 3.4系统特点 ................................................ - 8 - 3.5设备选型 ................................................ - 9 -4设备安装与调试.............................................. - 11 - 4.1线缆连接 ............................................... - 11 - 4.1.1馈线与泄漏电缆的连接 ............................. - 11 - 4.1.2图例 ............................................. - 12 - 4.2泄漏电缆的敷设 ......................................... - 13 - 4.3多套泄漏电缆埋设 ....................................... - 13 - 4.4 探测器的安装........................................... - 14 - 4.4.1探测器的安装 ..................................... - 14 -

电力线载波通信系统解读

摘要 电力线载波通信是以输电线路为载波信号的传输媒介的电力系统通信。由于输电线路具备十分牢固的支撑结构,并架设3条以上的导体(一般有三相良导体及一或两根架空地线),所以输电线输送工频电流的同时,用之传送载波信号,既经济又十分可靠。这种综合利用早已成为世界上所有电力部门优先采用的特有通信手段。这次的课程设计通过电力线在波芯片设计一个电力线载波通信系统。 电力线载波通信具有广阔的应用前景但由于电力线的噪声和干扰对信道的污染很大,严重影响了低压电线载波通信的质量。本文就电力线载波通信的优点缺点及发展现状进行了讨论,并分析了电力信道的噪声分类,特性及对我们信号的影响。以及我们对噪声的滤波耦合等。并且详细的介绍了电力线载波通信的具体实现形式方法和步骤最终形成一个系统达到我们的要求。 课程设计选用青岛东软的SSC1641的电力线载波芯片该芯片具有调制解条,a/d,d/a通信的功能,该芯片直接对信号数字信号处理,极大地提高了通信的可靠性。文中包括了他的外围电路,信号放大,耦合,滤波等最终实现功能。 实现了接收电力线的含有噪声的信号,然后对这个信号滤波模数转换等处理后通过串行通信的方式发送到过单片机,单片机经过数据处理后通过LCD1602显示出来,并且也通过串行通信发送到PC机显示出来。PC机或开关电路输入信号经过SSC1641处理后通过电力线发送。这样一个系统阶完成了接收与发送信号,形成了一个通信系统。 关键字:电力线载波通信系统SSC1641 调制解调 1、绪论 1.1设计任务及要求 电力线载波通信系统设计基本要求:下图一个电力线载波通信模块的结构组成,请看懂,并查阅资料了解电力线载波通信的原理和电力线载波芯片的技术资料。根据系统结构,完成载波芯片外的其他器件选型、配套硬件电路设计(包括原理图、PCB图)、软件设计和仿真调试。系统至少具备以下特性: 1)开关量输入和输出各5路; 2)系统24V供电; 3)具有通信状态指示功能; 4)有232、485或USB有线通信接口; 5)断电继续工作能力; 6)其他自己发挥的功能。

电力电缆施工解决方案

电缆敷设 1 工作流程: 准备工作 --- 支架安装--- 沿支架敷设--- 挂标示牌电缆头制作安装 --- 线路检查及绝缘摇测 2 工作具体操作要求: 2.1、施工前对电缆进行检查;规格、型号、截面、电压等级均符合设计要求,外观无扭曲、坏损等现象。 2.2、电缆敷设前进行绝缘摇测;1KV 以下电缆,采用 1KV 摇表测线间及对地的绝缘电阻应不低于10ΜΩ 2.3、选好电缆支架的架设点。架设时应注意电缆轴的转动方向,电缆引出端应在电缆轴的上方。 2.4、清除电缆沟内的杂物,准备好标示牌等。 2.5、将电缆敷设机用铁丝牢固固定在电缆桥架上面 3、电缆的敷设 3.1 人员到位后由班长发令开始,在所放电缆起端 1 米处贴上标签3.2 敷设电缆时应留出一定余量,以便检修及补偿温度变化产生的长度变化。 3.3 电缆电缆完毕后,应在电缆两端,竖井两端及电缆转弯处,挂上电缆标志牌,不同用途的电缆应用不同的标志牌区分。 3.4 有麻外护层的电缆引入室内或敷设在沟道内时,应将麻外护层剥去钢带外面涂一层防腐漆。 3.5 电缆敷设时,电缆应从盘的上端引出,不应使电缆在支架上及

地面磨擦拖位。电缆上不得有铠装压扁,电缆绞拧,护层折裂等未消除的机械损伤; 3.6 机械敷设电缆时,应在牵引头或钢丝套与牵引钢缆之间装设防捻器; 3.7 电缆敷设时,应排列整齐,不宜交叉。 3.8 电缆的最小弯曲半径应符合下表的规定: 电缆最小弯曲半径 表中 D 为电缆外径。 3.10 电缆进入电缆沟、隧道、竖井、建筑物、盘柜以及穿入管子时,出入口应封闭,管口应密封。 3.11 沟道内电缆的排列,电力电缆与控制电缆不应配置在同一层支

漏泄同轴电缆选用探讨

漏泄同轴电缆选用探讨 1.引言 漏泄同轴电缆可以实现任何地方的无线通信,甚至在有电磁波干扰或没有电磁波的地方都可以,例如:隧道、矿山、地铁、建筑大楼和大型、复杂的象展览馆或机场那样的场所。因为漏泄同轴电缆能保证信号覆盖的不间断性。 2.选用漏泄同轴电缆的依据 选择适当的漏泄同轴电缆要看其应用的需要,选择最合适的漏泄同轴电缆类型和规格由系统的设计和所有相关参数如使用频率、传输距离等决定。 选择漏泄同轴电缆有两个重要指标:传输衰减和耦合损耗。漏泄同轴电缆的系统损耗就是指传输衰减和耦合损耗的总和。传输衰减,也叫介入损耗,主要指传输线路的线性损耗,随频率而变化,以分贝/100米表示。耦合损耗是指通过开槽外导体从电缆散发出的电磁波在漏泄同轴电缆和移动接收机之间的路径损耗或信号衰减。因此系统损耗可以说是整个漏泄同轴电缆的损耗。因此在实际应用中,只要传输衰减能满足操作容限或链路容量的要求,就没必要选择那些传输衰减最低的漏泄同轴电缆,但对耦合损耗的要求会更严格一点。 在设计时要计算链路容量就得把所有发射器和接收机之间的增益和损耗加在一起,它还必须包括任何其他因素引起的损耗。如果计算结果为正值,那就表示有足够的容限允许环境发生变化,而系统仍可正常运行。 对漏泄同轴电缆而言,耦合损耗设计一般在55~85分贝之间。在狭长系统如隧道或地铁内,因为隧道或地铁本身能帮助提高漏泄同轴电缆的耦合性能,因此耦合损耗设计一般为75~85分贝,在这种条件下,把传输衰减减到最小非常重要。在建筑楼宇内,漏泄同轴电缆耦合损耗设计一般在55~65分贝之间,因为楼内漏泄同轴电缆单向长度在50~100米之间,因此传输衰减就不那么重要了,更重要的指标是漏泄同轴电缆能尽量多地发射信号,并穿透周围地区。 一个准备扩展的系统,可以选择传输衰减较小的漏泄同轴电缆。比如在办公楼内有一根顺电梯上行的漏泄同轴电缆,几个楼面共用一个接头,在这种情况下,若选择传输衰减低的漏泄同轴电缆,今后就可以提供更高频率上的服务或扩大服务覆盖区。

泄漏电缆方案要点

L3型泄漏电缆报警系统 解 决 方 案 上海广拓信息技术有限公司 2012年1月

目录 1、系统概述 (3) 2、泄漏电缆入侵探测器工作原理 (3) 3、泄漏电缆入侵探测器组成 (4) 4、泄漏电缆入侵探测器设备性能指标 (6) 5、泄漏电缆入侵探测器系统安装 (6) 6、泄漏电缆入侵探测系统应用 (8) 7、泄漏电缆入侵探测器调试说明............................................................................. 错误!未定义书签。 8、与红外对射报警系统的比较 (4) 9、技术支持与服务 (14) 10、系统设备配置和预算 (15) 11、泄漏电缆入侵探测器的公安部检验报告 (15) 12、部分案例图片参考 (15)

1、系统概述 泄漏电缆入侵探测报警系统是一种隐蔽式的主动型入侵探测报警系统,它由防盗报警控制主机、泄漏电缆入侵探测器和泄漏电缆、以及其它报警设备等组成。泄漏电缆埋在周界围墙或铁艺围栏内的草坪下或泥土下,不会破坏周围环境,不影响围界美观,人在不知觉的情况下,就会被泄漏电缆探测器探测到,是一种高科技的周界报警产品。它主要适用于银行、金库、住宅、监狱、仓库、博物馆、电站(包括核电站)、军事设施、军用基地、油田、文物保护单位和其他需要室外周边警戒防护的场所;在特殊要求的情况下,也可用作室内区域防护报警。 系统中涉及到的关键部件是一套发射和接收并存,敷设在防护区域地表浅层下的入侵探测电缆,它起到了主动、有效、安全、立体防范的入侵探测报警作用,此系统已通过公安部质量认证。 2、泄漏电缆探测器工作原理 发射单元产生高频能量馈入发射泄漏电缆中,并在电缆中传输。当能量沿泄漏电缆传送时,部分能量通过电缆的隙缝漏入空间,在被警戒空间范围内建立电磁场,其中一部分能量被安装在附近的接收泄漏电缆接收,形成收发能量直接耦合。当入侵者进入两根电缆形成的感应区内时,这部分电磁能量受到扰动,引起接收信号的变化,这个变化的信号经放大处理后被检测出来,触发泄漏电缆探测器(L3),再传到系统报警主机。再连接电脑加以显示出来,发出声音报警提醒值班人员及时处理警情。并结合图像监控复合,达到防盗报警,并及时处理的效果。如下图示:

电缆修复施工方案

电缆破损处理方案 批准: 审定: 审核: 编制: 中国机械工业第四建设工程有限公司 二O一六年四月二日

电缆破损处理方案 一、概况: 年月日上午时许,我单位组织人力敷设三一集团珠海工业园区4.5MW分布式光伏电站由光伏生产区到配电室ZR-YJYHD-4×185+1×95低压电缆。电缆总长700米,因电缆重量大,拐弯多,跨度长,电缆敷设过程中不能相互间很好的配合作业。电缆敷设至新桥架与老厂旧桥架交接的拐弯时,电缆被新桥架底棱边划伤。发现电缆划后立即停工,对拐弯处桥架进行处理。 经现场查看,电缆受损部分统计如下:外皮划伤共计?处,使用人力敷设电缆,因措施不当导致外皮和绝缘皮损伤,并未损坏电缆铜导体。 通过使用ZC-7 1000MΩ绝缘摇表,测得该电缆绝缘电阻值为500MΩ,说明该电缆虽然外表保护层破损,但主绝缘尚好或仅仅局部损伤。电缆敷设在桥架内,可以采取必要的维修措施,确保电缆送电后的安全运行。 二、编制依据: 《电气装置安装工程电缆线路施工及验收规范》GB50168-2006 《电气装置安装工程电气设备交接试验标准》GB50150-2006 三、维修工艺 1、检查电缆导体未受损。 2、检查并确认电缆各部位外皮和绝缘受损情况,做出标记。 3、恢复绝缘和电缆外保护层。 4、在维修部位悬挂电缆牌,标记回路名称及维修人 5、绘制维修示意图,在图上标记每个受损部位,作为日后检修依据。 四、维修方案 1、对该电缆外表进行细致检查,检查范围覆盖全部700米长范围,对发现的所有外皮损伤部位,使用红色塑料带做标识,作为工人维修时的标记。 2、对外皮受损部位进行处理。在外皮开裂位置、垂直电缆敷设方向将外保护层局部切开,注意不要伤到各相绝缘层。检查电缆各相绝缘是否破损。 3、对各相绝缘破损的部位,使用塑料绝缘带搭接缠绕,厚度4层,再用防水自粘带搭接缠绕,厚度4层。缠绕时,后一层塑料绝缘带和防水自粘带均应长出前一层10mm以上。 4、同一部位多相导体出现绝缘破损的,要分别进行绝缘处理,不得将两相缠绕在一起。 5、处理完各相绝缘。摇测电缆绝缘符合《电气装置安装工程电气设备交接试验标准》(GB50150-2006)要求。 6、整理电缆,具体做法:将原电缆护套梳理平顺,使用白布带将其紧密地缠绕,便于外防护层的包扎。 7、恢复电缆外保护层,具体做法:使用塑料绝缘带缠绕2

漏泄同轴电缆施工工法-secret要点演示教学

漏泄同轴电缆施工工法 一前言 为了解决铁路在山区、弯道、隧道内等弱场强或无场强区段的无线列调通信工程问题,目前采用在这些区段沿铁路线一定距离架设漏缆,安装隧道中继器和中继器天线的方式使无线电信号电波沿漏缆传输并均匀向外漏泄,使这些区段内场强达到一定要求而保证无线列调通信畅通、可靠。我们公司于1993年承担了某无线列调通信工程连江口至广州段的施工,在无施工规范和技术标准的情况下,我们在施工过程中边学习,边实践,边总结,用较短的时间,质量良好地完成了该段的施工任务。在完成任务的同时,锻炼了一支技术熟练、工艺精良的施工队伍。为了更好地指导今后同类工程的施工,我们在总结实践的基础上,编写了400MHz漏泄电缆的施工工法。期望本工法在今后指导同类工程施工实践的同时,不断地进行补充和完善,以取得更大的经济和社会效益。 二工法特点及适用范围 2.1本工法有如下特点: 2.1.1漏缆架设前要进行严格的单盘测试及合理的配盘。 2.1.2漏缆须架设在铁路旁距轨道线路中心3~15米范围内,其高度须距轨面4.5~4.8米。 2.1.3漏缆的漏泄槽应朝铁路一侧。 2.1.4漏缆接续按漏缆的型号不同须配用不同的连接器件,为控制电缆的耦合损耗,还须根据不同类型的电缆,确定其连接器的安装位置。 2.2本工法适用于山区、隧道传输信号,整个铁路系统及地下铁路,厂矿等漏泄电缆组成的无线通信系统工程的施工,同时也适用于从事漏缆维修人员进行维修工作。 三工艺原理

本工法是无线列调通信系统中的部分设备——漏泄电缆的施工工艺,其原理可从以下三个方面来说明: 3.1漏缆既是无线信号电波的传输线,又可视为无线信号的天线。 调度、车站值班员、机车司机互相通话,一般情况下,是靠车站电台通过天线向空间发射信号电波,在铁路沿线的空间产生一定的场强,并通过机车电台的天线耦合接收来实现的。而在弯道、山区、隧道内无线电波被阻挡、反射、吸收,使得该区段通信困难或无法通信。漏缆沿铁路架设,通过中继器和中继器天线,将车站电台发射的信号电波接收,经中继器放大加强,沿漏缆传输并均匀向外漏泄信号电波,使这些弱场强和无场强区段的铁路沿线具有一定大小的场强分布,以便在这些区段运行的机车电台能正常接收信号。同样,机车电台发射的信号电波也通过漏缆耦合,传输到中继器放大加强后送到中继器天线发射,被车站电台接收,从而实现调度、车站、机车的通信。因此,漏缆起到了传输、漏泄(天线)两方面的作用,成为山区、弯道、隧道内等弱场强或无场强区实现无线通信的关键设备之一。 3.2采用分级补偿的原则,从而使列车收到平稳的电平信号,同时与采用单一的漏缆相比,能延长通信距离。下面举一例说明: 3.2.1漏缆特性 型号 耦合损耗 传输损耗 149 80 dB/Km 25 dB/Km 148 70 dB/Km 27 dB/Km 147 65 dB/Km 36 dB/Km 3.2.2中继段的漏缆配置方法:在电波信号正向传输方向上,漏缆的配置顺序原则是 中继段漏缆配置图1 耦合损耗由大到小,传输损耗由小到大,以确保机车接收电平的曲线斜率最大限度最小,呈 Ⅰ 型 中继器 Ⅱ 型 中继器 DCX LCX 400m 400m 400m 147型 148型 149型 正向传播方向 A B C D

漏泄同轴电缆的介绍

漏泄同轴电缆简介 漏泄同轴电缆是具有信号传输作用又具有天线功能通过对处导体开口的控制可将受控的电磁波能量沿线路均匀的辐射出去及接收进来实现对电磁场盲区的覆盖已达到移动通信畅通的目的。 绝缘采用高物理发泡的均匀细密封闭的微泡结构不仅较之传统的空气绝缘结构在特性阻抗、驻波系数、衰减等传输参数更加均匀稳定而且可抵御在潮湿环境中潮气对电缆的侵入可能传输性能的下降或丧失免除了充气维护的烦恼大大提高了产品的使用寿命和稳定可靠性是当今世界上最先进的射频和漏泄同轴电缆结构。 选用漏泄同轴电缆的依据选择适当的漏泄同轴电缆要看其应用的需要选择最合适的漏泄同轴电缆类型和规格由系统的设计和所有相关参数如使用频率、传输距离等决定。选择漏泄同轴电缆有两个重要指标传输衰减和耦合损耗,漏泄同轴电缆的系统损耗就是指传输衰减和耦合损耗的总和,传输衰减也叫介入损耗主要指传输线路的线性损耗随频率而变化以分贝/100米表示。 耦合损耗是指通过开槽外导体从电缆散发出的电磁波在漏泄同轴电缆和移动接收机之间的路径损耗或信号衰减。因此系统损耗可以说是整个漏泄同轴电缆的损耗。 因此在实际应用中只要传输衰减能满足操作容限或链路容量的要求就没必要选择那些传输衰减最低的漏泄同轴电缆但对耦合损耗的要求会更严格一点。 在设计时要计算链路容量就得把所有发射器和接收机之间的增益和损耗加在一起它还必须包括任何其他因素引起的损耗。如果计算结果为正值那就表示有足够的容限允许环境发生变化而系统仍可正常运行。 对漏泄同轴电缆而言耦合损耗设计一般在5585分贝之间。 在狭长系统如隧道或地铁内因为隧道或地铁本身能帮助提高漏泄同轴电缆的耦合性能因此耦合损耗设计一般为7585分贝在这种条件下把传输衰减减到最小非常重要。 在建筑楼宇内漏泄同轴电缆耦合损耗设计一般在5565分贝之间因为楼内漏泄同轴电缆单向长度在50100米之间因此传输衰减就不那么重要了更重要的指

泄漏电缆分布系统的设计与应用

泄漏电缆集信号传输、发射与接收等功能于一体,同时具有同轴电缆和天线的双重作用,特别适用于覆盖公路、铁路隧道、城市地铁等无线信号传播受限的区域。链路预算是泄漏电缆分布系统设计中非常重要的一项工作,本文通过一个采用泄漏电缆进行地铁隧道覆盖的实例,介绍泄漏电缆分布系统链路预算的一般方法,并对泄漏电缆分布系统采用的放大器进行详细设计。 一、泄漏电缆简介 泄漏同轴电缆(Leaky Coaxial Cable)通常又简称为泄漏电缆或漏泄电缆,其结构与普通的同轴电缆基本一致,由内导体、绝缘介质和开有周期性槽孔的外导体三部分组成。电磁波在泄漏电缆中纵向传输的同时通过槽孔向外界辐射电磁波;外界的电磁场也可通过槽孔感应到泄漏电缆内部并传送到接收端。 目前,泄漏电缆的频段覆盖在450MHz-2GHz以上,适应现有的各种无线通信体制,应用场合包括无线传播受限的地铁、铁路隧道和公路隧道等。在国外,泄漏电缆也用于室内覆盖。 与传统的天馈系统相比,泄漏电缆天馈系统具有以下优点: ※信号覆盖均匀,尤其适合隧道等狭小空间; ※泄漏电缆本质上是宽频带系统,某些型号的泄漏电缆可同时用于CDMA800、GSM900、GSM1800、WCDMA、WLAN等系统; ※泄漏电缆价格虽然较贵,但当多系统同时引入隧道时可大大降低总体造价。 二、泄漏电缆链路的预算 链路预算的主要目的是校核初步设计的泄露电缆分布系统能否满足正常的通信要求,包括上下行接收强度的预算。如果系统中有射频放大器或采用无线直放站作为信号源,还应该进行上行噪声预算和下行交调预算。 下面以某地铁隧道覆盖为例,介绍链路预算的基本步骤和方法。 图1为该地铁站泄漏电缆分布的示意图,A向隧道长度为1500m,B向长度为500m。信号源为宏基站,载频数为4,每载频发射功率为46dBm,采用功分器将信号分为A、B两个方向,同时在B向通过功分器连接天线以覆盖地铁站台。系统覆盖要求为:90%的车内覆盖电平达到-85dBm。采用耦合型泄漏电缆,该电缆标称衰减为5.1dB/100m,50%的耦合损耗为72dB,在保证90%的覆盖概率时耦合损耗增加9dB,即90%的耦合损耗为72+9=81dB。

几种常用周界报警产品优缺点分析

几种常用周界报警产品优缺点分析: 1、红外对射式:利用不可见红外光对射原理,在投光器和受光器之间形成一个肉眼看不见的多束红外光栅组成的防范护栏,只要相邻两束红外光线被遮挡,即产生报警信号并自动向外发送警报。 优点:a安装简便,维护方便。 b隐蔽的防卫方式:使入侵者在不知不觉中触警。 c昆虫或小动物等通过防盗网时,由于不能完全遮断防卫射束,所以不会产生误报警。 d当隐形防盗网接收端电源线或信号线被剪断时,报警信号输出电路将自动输出无线报警信号。 缺点:a. 受天气、地形等外界影响比较大,安装容易有死角 b. 误报率相当高 c. 使用寿命短 2、激光对射:激光对射报警系统采用了808nm波长不可见光激光技术,易于隐蔽布防,可以垂直或水平安装在防范区域内。激光不会象无线电波、红外光那样,受到背景或不同温度物体的干扰。 优点: a 使用范围广 b 探测距离远,误报率低 c 抗干扰性强,对其它设备无干扰 d 防范性强适应环境范围更广 e 能耗低,可以全天候工作 缺点:a,不能适应复杂的周界环境 b 发散角度小,受地理环境影响,容易发生偏光现象 3微波对射式:由发射器和接收器构成,工作时在发射器和接收器之间形成三维立体的不可见微波探测区域,利用场干扰原理或波束阻断式原理来探测入侵者。一旦有人闯入防护区域,遮断微波探测波束时,系统立即产生告警信号。 优点: a由于微波对射工作于10GHz,工作频率远离了光谱,所以天气因素对它的工作影响很小,雪天、雾天也不会引起误报。同时微波产生的探测效果是立体波束,高和宽可以从几十厘米到10米可调,探测效果非常良好。 b微波对射式探测器可以和红外对射探测器共同使用,当两个探测器同时有报警信号时,才会有告警输出,降低了系统误报的可能性。 缺点:a. 微波传感辐射的电磁波对人体有害 b. 受雷达干扰,不适合用在空中交通和国防部 c. 发射器与接收器的距离影响探测率 d. 安装要求高,安装不合适,微波会透过窗外泄,进而产生误报 3、振动电缆式:采用驻极体振动电缆作为传感器,驻极体振动电缆是一种经过特殊充电处理后带有永久预置电荷的同轴电缆。使用时,将驻极体电缆用塑料带固定在栅栏或钢丝网面上,其一端与报警控制电路相连,另一端与负载电阻相连。当有入侵者翻越栅、网或割栅、网时,电缆因受到振动而产生模拟信号电压,即可触发报警。 缺点:a安装简便,可安装在原有的防护栅网、围墙、房顶等处,不需要费事费力地挖地槽。

数字通信技术及对电缆性能要求简介

数字通信技术和对电缆电性能要求简介通信的基本任务就是克服时域、时空障碍,迅速及时地传递信息。人类社会要进行信息交流就离不开通讯。通信是推动社会文明、进步及发展的巨大推动力。现代的人类社会已经进入信息时代。现代通信系统就是信息时代的生命线。 电线电缆(含光纤光缆)作为通信和通信系统传输信息的一种主要传输媒介,它的品种规格、电缆的结构和性能,它的生产制造工艺、新型材料的使用和发展,都和通信及通信系统的发展息息相关。因此电线电缆工作者,有必要对通信和通信系统有所认识和了解。 1通信 通信即信息的传送过程,就是把信息从一个地方传送到另一个地方。信息可以是声音、图像、数据、以及它们的各种组合。 现代通信是集声音、图像、文字为一体的综合性的多种信息服务体系。因此现代通信网已是一个综合业务数字网。为适应世界性的经济和政治活动的需要,人们已经建立起了世界性的全球通信网,现代通信已成为当今世界最重要的信息技术服务。 现代通信技术可分为:电通信和光通信两类。电通信又可分为有线通信(从架空通信明线到对称通信电缆、同轴电缆、光纤光缆)和无线通信(广播电视、微波接力、卫星等)。 2 信息 知识来源于信息,信息是事物运动状态及变化的反映。当今世界已步入信息时代,信息已成为经济发展的战略资源和独特的生产要素。

以远程通信网络计算机、视频等多媒体终端相结合建立起来的现代信息传输系统和完备的信息服务体系,已成为一个国家或地区经济发达程度的重要标志。 人类社会需要交流、沟通、传递的信息有声音、文字、符号、音乐、图像和数据以及它们的各种组合。如电视是声音和图像的组合,此时电视信息通常是被频率为几兆赫(MHz)到几百兆赫(THz)的电磁波所携带。 3,信号 现代通信的任务是传递信息、语音、图像和数据等,信息本身并不能直接快速地、远距离地传送。为此需要通过物理变化将语音、图像、数据转换成相应的电信号,这些电信号再经过处理(调制)后乘载在高频载波上,已调制的载波以电磁波的形式在信道(有线或无线)中传输。在接受端再将电信号,还原(解调)成原有的语音、图像、数据等信息。 现在普遍采用的是用电信号进行的电通信;目前的光通信网通信采用的已然是采用光——电——光(OEO)技术,即将电信号转化成光信号,然后在光纤光缆中传输,在系统的接受端再将光信号转换成电信号。在高速数据传输时,采用这种光电子转换方法的价格相当高。在40Gb/s下的电信号的交换已经相当困难。 随着光通信技术的发展,今后将会实现全光通信。全光通信,它是在发送端将各种信息转换成光信号发送出去,然后在接收端把光信号还原,实现信息的传递是以光传输方式进行的,网络的交换功能直接

泄漏电缆传输系统设计与应用论文

泄漏电缆传输系统的设计与应用 摘要:本文对泄漏同轴电缆传输系统的特点、适用场所和泄漏同轴电缆的结构特点及其主要技术参数作了简要介绍;并以某地铁隧道泄漏电缆传输系统设计为实例,详细说明了链路计算和系统设计方法,最后还介绍了自由空间电磁场场强的测试方法。 关键词:泄漏同轴电缆,地铁隧道,链路计算,场强测量 abstract: in this paper, the leakage coaxial cable transmission system characteristics, application places and leak coaxial cable structural features and main technical parameters were briefly introduced; and with a subway tunnel leakage cable transmission system design, for example, a detailed description of the link calculation and system design method, at last, this paper introduces the electromagnetic field of the free space of the field test method. keywords: leakage coaxial cable, the subway tunnel, link calculation, the field measurement 中图分类号: tm247 文献标识码:a 文章编号: 隧道、地铁、矿井、车站和地下停车场等都是空间狭窄的特殊通信区域,影响无线信号正常传输;此外,由于车体对信号的遮挡,车辆行驶速度快,导至隧道内的通信信号极差,产生通信盲区。采

泄漏电缆周界入侵防范系统

泄漏电缆周界入侵防范系统 功能简介:泄漏电缆周界入侵警戒系统是一种用于室外的周界入侵探测系统,在埋地感应电缆周围产生不可见的电磁场。 当有人干扰该电磁场时,就会触发报警。 原理简介:本系统采用的是一种均匀的空间场,对移动目标的导电性、体积、移动进行探测。 人或车通过该电磁场都会被探测到,而小动物或鸟类却不会引起报警。 主要设备:系统的主要传感器是一种地表浅埋式电缆,不仅可用于地形规则的被警戒区域周边,亦可用在野外地形较为复杂的区域(如高低不平的山区及周界转角等). 通过对人体、或者活动金属物体以及对重量30 公斤以上的动物探测报警,达到有效安全防范的目的。 泄漏电缆周界入侵警戒系统的特色: A.探测电缆埋于周界地下或墙内,隐蔽不易发觉。 B.不受周围环境的影响,系统适应性强,如植被、雨、雪、风沙等。C.超强的稳定性,探测灵敏度均匀。 D.可与其它报警系统结合,构成强大的大范围区域安全警戒系统。E.当有人入侵时,可准确判断入侵者所处的区段。 区别于国内泄漏电缆警戒系统,泄漏电缆周界入侵警戒系统具有以下优势: 1、超强的稳定性――――不受温度变化的影响

2、完美的适应性――――适合于各类复杂周界 3、简便的安装方式――――插头均为即插件 4、具备防宠物误报功能――――可将小动物在防护区内移动过滤,消除误报情况 5、精准的灵敏度调节――――四档灵敏度调节和微调旋钮 6、合理的人性化设计――――外壳采用IP54防水等级,电路板零部件均经过防腐蚀处理 7、抗干扰能力强――――采用高性能数字信号处理器(DSP),具备硬件电路和软件系统的双重抗干扰设计。 8、隐蔽性好――――埋地或埋墙式安装不易被发现埋地泄漏电缆周界入侵警戒系统的施工: 埋地泄漏电缆周界入侵警戒系统采用泄漏感应电缆产生不可见的电磁场。 在发射电缆的外层导体开槽,使得电场能量外泄,由另一根并行的接收电缆来探测泄漏出来的电场的能量分布。 感应电缆可以埋在任何介质里,如土壤、沙地、粘土、混凝土或沥青等,形成一个统一的、隐蔽的、依地形而建的立体探测场。 安装系统时,感应电缆尽量铺设在带状区域(该区域最好保证宽4米以上)的中间,远离任何能动的金属物体; 感应电缆距离大型移动的金属物体(如链状围栏)的距离至少2米远。每个防区的长度可以从10米到100米,根据保护区的具体要求来设计。

电缆迁移方案

电缆迁移方案

文档仅供参考,不当之处,请联系改正。 黎湛线信号电缆迁移施工组织设计方案 编制: 审核: 审批: 中铁电气化局黎湛项目部 8月

目录 一、编制依据 ............................................................... 错误!未定义书签。 二、工程概况 ............................................................... 错误!未定义书签。 三、施工人员组织 ....................................................... 错误!未定义书签。 1.指挥组 .............................................................. 错误!未定义书签。 2.施工组 .............................................................. 错误!未定义书签。 3.防护组 .............................................................. 错误!未定义书签。 四、实施方案 ............................................................... 错误!未定义书签。 1.计划时间 .......................................................... 错误!未定义书签。 2.签订协议 .......................................................... 错误!未定义书签。 3.安全教育 .......................................................... 错误!未定义书签。 4.主要工机具....................................................... 错误!未定义书签。 5.具体施工步骤................................................... 错误!未定义书签。 第1步:电缆探测、现场调查....................... 错误!未定义书签。 第2步:电缆迁移至新电缆沟内埋设。 ....... 错误!未定义书签。 6、对电务、工务及车站部门要求 ....................... 错误!未定义书签。 五、保证施工时设备正常使用措施............................ 错误!未定义书签。

相关文档
最新文档