熔断器规格

熔断器规格
熔断器规格

0805贴片自恢复保险丝系列型号尺寸规格书

(a) RoHS Compliant & Halogen Free (b) Applications: All high-density boards (c) Product Features: Small surface mountable, Solid state, Faster time to trip than standard SMD devices, Lower resistance than standard SMD devices (d) Operation Current: 0.10A~1.10A (e) Maximum Voltage: 6V~24V DC (f) Temperature Range : -40℃ to 85℃ 2. Agency Recognition UL : File No. E211981TüV: File No. R50090556 3. Electrical Characteristics (23℃) H I T =Trip current-minimum current at which the device will always trip at 23℃ still air. V MAX =Maximum voltage device can withstand without damage at it rated current.(I MAX ) I MAX = Maximum fault current device can withstand without damage at rated voltage (V MAX ). Pd=Typical power dissipated-type amount of power dissipated by the device when in the tripped state in 23℃ still air environment. R MIN =Minimum device resistance at 23℃ prior to tripping. R 1MAX =Maximum device resistance at 23℃ measured 1 hour after tripping or reflow soldering of 260℃ for 20 seconds. Termination pad characteristics Termination pad materials: Pure Tin

快恢复保险丝规格书

Description The PICO ? II Slo-Blo ? Fuse combines time-delay performance characteristics with the proven reliability of a PICO ? Fuse.Agency Approvals Features Electrical Characteristics t &OIBODFE JOSVTI XJUITUBOE t 4NBMM TJ[F t 8JEF SBOHF PG DVSSFOU SBUJOHT N" " t 3P)4 DPNQMJBOU t )BMPHFO GSFF BWBJMBCMF t 8JEF PQFSBUJOH UFNQFSBUVSF SBOHF t -PX UFNQFSBUVSF EF SBUJOH Applications Electrical Characteristics t 'MBUoQBOFM %JTQMBZ 57 t -$% NPOJUPS t -JHIUJOH TZTUFN t .FEJDBM FRVJQNFOU t *OEVTUSJBM FRVJQNFOU

?2009 Littelfuse, Inc. 473 Series Average Time Current Curves 1000 100 10 1 0.1 0.01 1000 100 101 0.1 .375A .50A .75A 1.0A 1.5A 2.0A 2.5A 3.0A 3.5A 4.0A 5.0A 7.0A T I M E I N S E C O N D S CURRENT IN AMPERES T emperature Rerating Curve Soldering Parameters Recommended Hand-Solder Parameters:4PMEFS *SPO 5FNQFSBUVSF ? $ ?$)FBUJOH 5JNF TFDPOET NBY Note: These devices are not recommended for IR or Convection Reflow process. Recommended Process Parameters: /PUF %FSBUJOH EFQJDUFE JO UIJT DVSWF JT JO BEEJUJPO UP UIF TUBOEBSE EFSBUJOH PG GPS continuous operation.

自恢复保险丝选型方法

自恢复保险丝如何选型 自恢复保险丝是一种过流电子保护元件,采用高分子有机聚合物在高压、高温,硫化反应的条件下,搀加导电粒子材料后,经过特殊的工艺加工而成。习惯上把PPTC叫做自恢复保险丝。自恢复保险丝主要的作用是用来做电器中做过流保护作用。因此自恢复保险丝有耐压值,耐流,维持电流,动作时间等参数。因此在自恢复保险丝选型是要根据所用产品的电压,电流和保护电流等来选择合适的产品。方法如下: 1.首先确定被保护电路正常工作的最大环境温度,电路中工作电流,最大工作电压,要求的保护电流,动作时间等参数 2.根据被保护电路或产品的特点选择出适用的自恢复保险丝是插件保险丝还是贴片保险丝。 3.根据最大工作电压选择出耐压等级大于或等于最大工作电压的产品系列 4.根据电路工作最大环境温度和电路中工作电流,对照自恢复保险丝温度折减率选出维持电流适合的产品规格 5.根据该型号的自恢复保险丝的动作时间曲线图确认选出的产品是否符合要求动作保护时间。 6.对照规格书中提供的数据,确认该种规格热敏电阻的尺寸符合要求。 例如,某控制电路需要过流保护,其工作电压为48伏特、电路正常工作时电流为450毫安、电路的环境温度为50℃。要求电路中电流达到1.4安培时实现保护和电路为5安培时2秒内能够对电路进行迅速保护。我们可以根据其工作电压48伏特,首先选择耐压等级为60伏特的wh60系列自恢复保险丝产品,然后对照该系列产品的维持电流与温度关系列表选择wh60-065或wh60-075两种规格的产品,再根据动作时间与电流的关系图发现,5安培时wh60-065和wh60-075的动作时间都为1秒钟左右的动作时间,但是wh60-065的保护动作电流1.3安培不符合要求,因而最终应选择wh60-075规格的自恢复保险丝。 根据以上例子可以看出,自恢复保险丝的选型可以根据上面的6步法进行选型。但是很多要求保护的电路很复杂,具体的选型还是要根据具体情况进行选型后最经过实验测试后最确定最终合适的产品。

好利来保险丝1A 250V规格书

Hollyland (China) Electronics 本规格书适用于本公司生产并获得CQC 、UR/CUR 、SEMKO 、PSE 、VDE 、BSI 、KC 认证的5ET RoHS 系列HOLLY 商标的超小型保险丝。This specification defines the technical requirements of sub-miniature fuse type 5ET RoHS series with HOLLY ? 产品部件号为: brand, which are approved by CQC, UR/CUR, SEMKO, PSE, VDE 、BSI and KTL. 型号 额定电流 额定电压 Construction of part no: type rated current rated voltage 5ET 0100 H A 型号规格: 型号 特性符号 额定电流 MODEL DETAIL: 额定电压 Type Characteristic Symbol Rated Current 例如/ Example: Rated Voltage 5ET T 2 A *特性符号/ Characteristic Symbol: T – 慢断型/ Time-Lag. 250V 2. 相关标准及认证情况/ APPLICABLE STANDARDS & APPROVED DETAILS 2.1 5ET RoHS 系列产品适用的相关标准是 IEC 60127和GB 9364。 Applicable standards for 5ET RoHS series are IEC 60127 and GB 9364.

萨特科技贴片保险丝规格书

Product Catalog

Company Introduction SART Technology﹐the first Chinese manufacturer of SMD fuse﹐was founded in 2006﹒SART has devoted itself to research and develop circuit protection devices ever since﹒ SART’s facility in Nanjing are certified by TS16949, ISO 9001 and ISO14001﹒Our main products include SMD fuses and Current Sensing Resistors(CSR)﹒ Our SMD fuses have been widely used in different applications like LCD panels、battery packs、battery chargers、digital cameras、cell phones etc﹒ SART ceramic 6125 fuses with raw material originated from Germany have the advantage of a higher breaking capacity﹐facilitating their use in circuits with higher current and voltage﹒Our current sensing resistors(CSR) have great competitive edge in terms of ultra low ohm﹐low TCR﹐tight tolerance﹐high withstanding surge current and low thermal EMF﹒They are designed for current detecting and can be perfectly utilized by intelligent Li-ion rechargeable batteries﹒ With our mission in mind﹐SART has made huge investment in building a strong R&D team﹐a global sales team and an international management team to provide our best service to global customers﹒SART’s mission and commitment are ﹕ S ervice: Global sales offices and on-time delivery A ffordability: Best quality for best prices available R ecognition: Win trust and award from major customers T echnology: Innovative technology for the market YOU GIVE US AN OPPORTUNITY; WE PROMISE YOU THE FUTURE!

保险丝知识介绍及选型计算

: 保险丝的应用: 一、保险丝的应用 1. 正常情况下,保险丝在电路中起连接电路作用。 2. 非正常(超负载)情况下,保险丝做为电路中的安全保护元件,通过自 身熔断安全切断并保护电路。 : 二、保险丝的工作原理 保险丝的工作原理: 保险丝通电时,由电能转换的热量使可熔体的温度上升。正常工作电流或允许的过载电流通过时,产生的热量通过可熔体、外壳体向周围环境辐射,通过对流、传导 等方式散发的热量与产生的热量逐渐达到平衡。如果产生的热量大于散发的热量,多余的热量就逐渐积聚在可熔体上,使可熔体温度上升;当温度达到和超过可熔体 的熔点时,就会使可熔体熔化、熔断而切断电流,起到了安全保护电路的作用。 : 保险管的关键参数: 三、保险管的关键参数 3.1 额定电流---In 保险丝的额定电流是指它的公称额定电流, 通常就是电路能够工作的最大电流值。 正确选择保险丝的额定电流值, 必须作如下考虑: 电路的工作电流: 例如: Ir = 1.5 A, UL规格保险丝额定电流应是: In = Ir/Of = 1.5/0.75 = 2A ,这儿的Ir是电路工作电流,Of 是UL 规格保险丝的折减率,所以应该选择2A 的保险丝。对于IEC规格保险丝则没有折减率要求, 即: Ir = In ,如果特殊的额定电流不是通用的, 应该选最邻近的较高值。 错误的选泽:把希望保险丝熔断的电流值作为额定电流值

3.2 额定电压---Un 保险丝的额定电压是指它的公称额定电压, 通常就是保险丝断开后能够承受的最大电压值。 保险丝通电时两端所承受的电压大大小于其额定电压,因此额定电压基本上无关紧要。正确选择保险丝额定电压应该等于或大于电路电压,例如: 250V 的保险丝可以用于 125V 的电路 。对于低电压的电子应用, 一个交流额定保险丝可以用于直流电路中。 关于保险丝的额定电压主要应考虑: 当电路电压不超过熔断器额定电压时, 保险丝是否有能力分断给出的最大电流 3.3 环境温度 保险丝所处小环境温度或已知的工作温度, 对保险丝的动作是有影响的 。环境温度越高, 保险丝的工作时就越热, 其寿命也就越短 。不管是 UL 规格还是 IEC 规格, 保险丝的各项指标都是指在25 ℃ ,如小环境工作温度较高,则要考虑保险丝的温度降额。 例: 选用快熔断保险丝在 90 0C 小环境下和 1.5A 电流下工作,,若选用 IEC 规格保险丝, 那么额定电流就是: In = In/ Tf = 1.5A/0.95 = 1,58 A 推荐 1.6 A 或 2 A 的保险丝 若选用UL 规格保险丝 那么额定电流就是: In = In/OfxTf = 1.5A/0.75x0.95 = 2.1 A 应选 2.5 A 的保险丝 3.4 3.4 电压降电压降/冷电阻---Ud/R 一般情况下,保险丝的电阻值与它的额定电流值成反比。 在保护电路中要求保险丝阻值越小越好,这样它的损耗功率就小;因此在保险丝技术参数中规定了最大电压降值或冷电阻值,但不作为产品验收依据。 保险丝的电压降:通以直流额定电流,使保险丝达到热平衡后所得的读数。 保险丝的冷电阻:在小于额定电流10%的条件下测得的读数 保险丝的电压降和冷电阻可以互相换算。 注意:小规格保险丝的电压降对低压电路的影响较大,务必注意! 极端情况下由于电阻太大会无法输出需要的工作电流。

熔断保险丝1206SB封装型号参数规格书

Features: ? High inrush current withstanding capability ? Multilayer monolithic structure with glass ceramic body and silver fusing element ? Silver termination with nickel and pure-tin solder plating, providing excellent solderability ? Standard EIA1206/EIAJ3216 size ? Compatible with both wave and reflow soldering processes ? Operating temperature range: -55°C to +125°C (with de-rating) ? RoHS compliant Agency Approval: Recognized Under the Components Program of Underwriters Laboratories. File Number: E232989 Ordering Information: Clear-Time Characteristics ( Slow Blow): Interrupting Ratings: 1A - 5.5A 50A at rated voltages 6A - 8A 60A at rated voltage Shape and Dimensions: SOLDER FUSE ELEMENT NICKEL SILVER METALLIZATION Patents: U.S. Patent numbers 6,034,589; 6,228,230; 6,602,766; 7,268,661 B2; and other pending patents. 1. Measured at ≤ 10% of rated current and 25oC ambient 2. Melting I 2t at 0.001 sec clear-time % of current rating Clear-time at 25 o C 100% 4 hours min. 200% 1 second min. 120 seconds max. 300% 0.1 seconds min. 3 seconds max. 800% 0.002 seconds min. 0.05 seconds max. Revision:18-Jul-15

熔断器的主要技术参数和熔断器的保护特性

熔断器的主要技术参数 (1)额定电压熔断器长期工作时和分断后能够耐受的电压,其量值一般等于或大于电气设备的额定电压。 (2)额定电流熔断器能长期通过的电流,它决定于熔断器各部分长期工作时的容许温升。 (3)极限分断能力熔断器在故障条件下能可靠的分断最大短路电流,它是熔断器的主要技术指标之一。 (4)弧前电流—时间特性。 (5)I2t特性当分断电流甚大时,以弧前电流—时间特性表征熔断器的性能已足够了,因为此时燃弧时间在整个熔断时间并不能忽略。又由于这时电流在20ms甚至更短的时间内就分断,若以正弦波有效值来表示它,则在分析其热效应方面也不够恰当,因此,要通过积分(∫t0 idt)来表示热效应,这就是I2t特性。通常,熔断器的保护性能在熔断时间小于0.1s时是以I2t特性表征的;在熔断时间大于0.1s时,则用弧前电流—时间特性表征的。 (6)断开过电压熔断器分断电路时因线路有电感所出现的、超过线路额定电压数倍的自感电势,它既会影响熄弧过程,也可能损坏线路和电气设备的绝缘。对于具有限流作用的熔断器,断开过电压相当高,对此尤应注意。 熔断器的保护特性 熔断器的保护特性亦可称熔化特性,它是熔断器的主要特性。熔化特性表征通过熔体的电流与熔体熔化时间的关系,它和热继电器的保护

特性一样,都是反时限的。 熔断器的保护特性中有一熔断电流与不熔断电流的分界线,与此相应的电流就是最小熔化电流IR。它是这样一个电流值,当通过熔体的电流等于它时,熔体在额定电流下绝对不应熔断,故IR>Ie。 最小熔化电流与熔体的额定电流之比称为溶化系数β,它是表征熔断器保护小倍数过载时的灵敏度的指标。从过载保护的观点来看,β小,对小倍数过载有利,例如,从电缆和电动机的过载保护来看,β值宜在1.2~1.4之间。如果β值小到接近于1,则不仅在熔体Ie下的工作温度会过高,而且还有可能因安—秒特性本身的误差而发生熔体在Ie 下也熔断的现象,这就影响了熔断器工作的可靠性。 熔化系数主要决定于熔体的材料和工作温度以及它的结构。 熔断器的熔断时间为熔化时间与燃弧时间之和。在小倍数过载时,熔断时间接近于熔化时间,燃弧时间往往可忽略不计,故熔化特性也就是熔断器的弧前电流—时间特性。 应当指出,由于熔体材料成分的变化,熔体尺寸的偏差及其表面状态和冷却条件的变化,熔断器接触不良以及周围介质温度的变化,使熔断时间也发生变化,以致熔断器的保护曲线不稳定,形成一个有10~20%误差的一条带。这样,就有可能发生在Ie下熔断,而在小倍数过载时反而不熔断的现象。在安装和使用熔断器时,均应充分注意到这一点。

自恢复保险丝SMD0603封装参数型号规格书大全

The SMD0603 Series PTC provides surface mount over-current protection for applications where space is at a premium and resettable protection is desired. u RoHS compliant, Lead-Free and Halogen-Free u Fast time-to-trip u Compact design saves board space u Low resistance u Low-profile u Mobile phones - battery and port protection u Game console port protection u USB peripherals u Disk drive u PDAS / digital cameras u Power ports u General electronics Hold Current Trip Current Rated Voltage Max Current Typical Power Maximum Time To Trip Resistance Part Number I hold (A) I trip (A) V max (Vdc) I max (A) P dtyp. (W) Current (A) Time (Sec.) R min (Ω) R 1max (Ω) SMD0603-010 0.10 0.30 15 40 0.5 0.50 1.00 0.90 6.00 SMD0603-020 0.20 0.50 9.0 40 0.5 1.00 0.60 0.55 3.50 SMD0603-025 0.25 0.55 9.0 40 0.5 8.00 0.80 0.50 3.00 SMD0603-035 0.35 0.75 6.0 40 0.5 8.00 0.10 0.20 1.40 SMD0603-050 0.50 1.00 6.0 40 0.5 8.00 0.10 0.10 0.80 SMD0603-075 0.75 1.50 6.0 40 0.5 8.00 0.10 0.06 0.45 SMD0603-100 1.00 2.00 6.0 40 0.5 8.00 0.10 0.04 0.30 I hold = Hold current: maximum current device will pass without tripping in 23°C still air. I trip = Trip current: minimum current at which the device will trip in 23°C still air. V max = Maximum voltage device can withstand without damage at rated current (I max ) I max = Maximum fault current device can withstand without damage at rated voltage (V max ) P dtyp.= Power dissipated from device when in the tripped state at 23°C still air. R min = Minimum resistance of device in initial (un-soldered) state. R 1max = Maximum resistance of device at 23°C measured one hour after tripping. Caution: Operation beyond the speci ?ed rating may result in damage and possible arcing and flame.

2009型 T1A250V方形保险丝规格书

HONGDA ELECTRONIC 1. 适用范围Scope of application 本产品适用于各种电子电器内的电路中起过电流保护作用。 This product is suitable for various kinds of electronic machines to work for over current protection. 2. 相关标准及认证Relevant Standards and Certification 2.1执行标准Standard :IEC60127-1 IEC60127-3 GB9364.1 GB9364.3 2.2认证Certification : 3. 结构及尺寸Structure and Size (unit: mm) 4. 5. 标示Marking 保险丝应印有下列标示:The fuse shall have the following marking : 泓达标志 + 型号 +延时型符号 + 额定电流+ 额定电压 + 认证符号 HONGDA’s logo+ model + Electrical characteristics +Ampere rating + V oltage rating +Approved Symbol 2009 T 1A 250V 泓达保险丝 H O N G D A F U S E C US

HONGDA ELECTRONIC 6. 外观Appearance 6.1外观不应有显著的污点、裂纹。 There shall not be any remarkable stain ,rust or crack on the appearances. 6.2标示应该很容易辨识。 Marking shall be easily legible. 7. 机械特性Mechanical characteristics 7.1 拉力强度试验Tensile test 将保险丝固定好后,对保险丝两端引线施加5N 的轴向拉力,持续1分钟。试验过后,保险丝没有任何破损现象。 Exert the axial pulling force of 5N to the both ends of lead wire for 1 minute. After the test the fuse shall be no damage and loosening. 8. 电气特性Electrical characteristics 8.1 实验条件Test condition 所有测试环境温度为25±5℃。 All electrical characteristics tests are conducted at an ambient temperature of 25±5℃. 8.2 分断能力Interrupting rating test 保险丝能承受的分断能力:35A 或10倍的额定电流当中较大的。分断能力测试后测得保险 丝的绝缘阻抗值大于0.1ΜΩ。 The fuse interrupting capacity :35A or 10 times the rated current whichever is greater. After interrupting, the insulation resistance between the fuse terminations shall be not less than 0.1ΜΩ. 8.3 温度上升试验:通1.5倍额定电流15分钟,然后每隔15分钟增加0.1倍额定电流。测得保 险丝断开时任何部位的温升不得超过135℃ ,周围环境温度为25±5℃。 Temperature Rising Test: The rated current of 1.5 times is applied for 15 minutes. After the first 15 minutes, the current is increased by 0.1 times the rated current every 15 minutes until the fuse operates. The temperature rising on the fuse surface is not higher than 135℃. 8.4 泓达保险丝 H O N G D A F U S E

美国BUSSMANN PV系列太阳能光伏专用熔断器规格书

Standards/Approvals: IEC 60269, UL 2579, RoHS compliant, UL Listed (1-15A) E335324Description: A range of fuse links in a 10x38mm package specifically designed for the protection and isolation of photovoltaic strings. The fuse links are capable of interrupting low overcurrents associated with faulted PV (reverse current, multi-array fault) string arrays. Packaging: MOQ: 10 Packaging 100% recyclable Technical Data:Rated Voltage:1000Vdc Amps:1-6A, 8-15A and 20A Rated Breaking Capacity:Min Interrupting Rating: 1.3 x I n PV Fuse Coordination w/: Thin film cells and 4”, 5” and 6” crystalline silicon cells. Time Constant: Under 1 ms Catalogue Symbol: PV-(amp rating)A10F PV-(amp rating)A10-T PV-(amp rating)A10-1P PV-(amp rating)A10-2P Class of Operation:gPV and UL PV fuse links Fuse Holders: PCB Clip: 1A3400-09Modular fuse holder: CHM1D-PV-IEC CHPV1 (1-pole non-indicating)CHPV1I (1-pole neon indicating) Dimensions - mm PV Series UL IEC 1-6A 10kAdc 40kAdc 8-15A 10kAdc 33kAdc 20A N/A 10kAdc

保险丝选择的主要参数

保险丝选择的主要参数: 1. 电压额定值(Voltage Ratings): 保险丝的电压额定值必须大于或者等于断开电路的最大电压。由于保险丝的阻值非常低,只有当保险丝试图熔断时,保险丝的电压额定值才变得重要。当熔丝元件熔化后,保险丝必须能迅速断开,熄灭电弧,并且阻止开路电压通过断开的熔丝元件再次触发电弧。 2. 电流额定值(Current Ratings):电流额定值表明了保险丝在一套测试条件下的电流承载能力。每只保险丝都会注明电流额定值,这个值可以是数字,字母或颜色标记。可以通过产品数据表找到每种标记的意义。 3. 分断能力(Breaking Capacity/Interrupting Rating):保险丝必须能在不破坏周围电路的情况下断开故障电路。分断能力就是指在额定电压下,保险丝能够安全断开电路,并且不发生破损时的最大电流值。保险丝的分断能力必须等于或大于电路中的可能发生的最大故障电流。 4. 熔断积分(Melting Integral):保险丝的熔断积分,是熔断这一保险丝的熔丝元件所需的能量,也称之为熔断值I2t。熔丝元件的结构、材料和横截面积决定了这个值。每一系列保险丝根据额定电流值不同,使用了不同的材料和元件配置,因此确定每只保险丝的I2t 非常必要。通常在直流电路中,采用10 倍的额定电流作为故障电流,使保险丝在极短的时间内断开,通过高速示波 仪和积分程序来测得非常精确的I2t。 5. 环境温度(Ambient Temperature):环境温度是直接接触在保险丝周围的空气温度,不是指室温。保险丝的电特性在25°C 环境温度中是额定的标准值。无论高于或低于这个温度都会影响保险丝的断开时间和电流承载特性。具体请参考网站的温度—电流曲线图。 6. 快断保险丝和慢断保险丝(Fast Acting Fuse & Time Delay Fuse):快断保险丝在过载和短路时断开地非常迅速。UL 标准规定:快断保险丝在承受200%~250%的额定电流时,应该在最多 5 秒钟之内断开。IEC 对于快断保险丝的规定有两种: F = 快断,当10 倍额定电流时在0.001~0.01 秒内断开FF = 超快断,当10 倍额定电流时小于0.001 秒断开 慢断保险丝可以允许暂时的、无害的浪涌电流通过而不断开,但是当持续过载或短路时,它就会断开。UL 标准规定:慢断保险丝在承受200%~250%的额定电流时,应该在最多 2 分钟之内断开。IEC 对于快断保险丝的规定也有两种: T = 慢断,当10 倍额定电流时在0.01~0.1 秒内断开TT = 超慢断,当10 倍额定电流时在0.1~1 秒内断开 7. 浪涌和脉冲电流特性(Surge and Pulse Current Characteristics):有些使用场合会产生浪涌电流,这样就要求保险丝能够使这些浪涌电流通过而不发生误断开

跌落式熔断器详细参数

乐清市西高电器 跌落式熔断器作用 跌落式熔断器是10kV配电线路分支线和配电变压器最常用的一种短路保护开关,它具有经济、操作方便、适应户外环境性强等特点,被广泛应用于10kV配电线路和配电变压器一次侧作为保护和进行设备投、切操作之用。 跌落式熔断器安装在10kV配电线路分支线上,可缩小停电范围,因其有一个明显的断开点,具备了隔离开关的功能,给检修段线路和设备创造了一个安全作业环境,增加了检修人员的安全感。安装在配电变压器上,可以作为配电变压器的主保护,所以,在10kV配电线路和配电变压器中得到了普及。 落式熔断器常用型号器 RW12-15,RXWO,RW12-12,RW11-10,RW10-10F,RW7-10,RW5-35,RW4-10,RW3-10,PRWG2-35 ,PRWG1-10F,HY5WS,HRW12-12,HRW11-10,HRW10-10F,HRW7-10,HRW5-35,HPRWG2-35 跌落式熔断器安装操作 (1) 安装时应将熔体拉紧(使熔体大约受到24.5N左右的拉力),否则容易引起触头发热。 (2) 熔断器安装在横担(构架)上应牢固可靠,不能有任何的晃动或摇晃现象。 (3) 熔管应有向下25°±2°的倾角,以利熔体熔断时熔管能依靠自身重量迅速跌落。 (4) 熔断器应安装在离地面垂直距离不小于4m的横担(构架)上,若安装在配电变压器上方,应与配变的最外轮廓边界保持0.5m以上的水平距离,以防万一熔管掉落引发其他事故。 (5) 熔管的长度应调整适中,要求合闸后鸭嘴舌头能扣住触头长度的三分之二以上,以免在运行中发生自行跌落的误动作,熔管亦不可顶死鸭嘴,以防止熔体熔断后熔管不能及时跌落。 (6) 所使用的熔体必须是正规厂家的标准产品,并具有一定的机械强度,一般要求熔体最少能承受147N以上的拉力。 (7) 10kV跌落式熔断器安装在户外,要求相间距离大于70cm。 一般情况下不允许带负荷操作跌落式熔断器,只允许其操作空载设备(线路)。但在农网10kV配电线路分支线和额定容量小于200kV A的配电变压器允许按下列要求带负荷操作: (1) 操作时由两人进行(一人监护,一人操作),但必须戴经试验合格的绝缘手套,穿绝缘靴、戴护目眼镜,使用电压等级相匹配的合格绝缘棒操作,在雷电或者大雨的气候下禁止操作。 (2) 在拉闸操作时,一般规定为先拉断中间相,再拉背风的边相,最后拉断迎风的边相。这是因为配电变压器由三相运行改为两相运行,拉断中间相时所产生的电弧火花最小,不致造成相间短路。其次是拉断背风边相,因为中间相已被拉开,背风边相与迎风边相的距离增加了一倍,即使有过电压产生,造成相间短路的可能性也很小。最后拉断迎风边相时,仅有对地的电容电流,产生的电火花则已很轻微。 (3) 合闸的时候操作顺序拉闸时相反,先合迎风边相,再合背风的边相,最后合上中间相。 (4) 操作熔管是一项频繁的项目,注意不到便会造成触头烧伤引起接触不良,使触头过热,弹簧退火,促使触头接触更为不良,形成恶性循环。所以,拉、合熔管时要用力适度,合好后,要仔细检查鸭嘴舌头能紧紧扣住舌头长度三分之二以上,可用拉闸杆钩住上鸭嘴向下压几下,再轻轻试拉,检查是否合好。合闸时未能到位或未合牢靠,熔断器上静触头压力不足,极易造成触头烧伤或者熔管自行跌落。

自恢复保险丝JK30封装参数型号规格书大全

UN30 series radial leaded PTCs are designed to provide over-current protection for low voltage (≤30V) applications where space is not a concern and resettable protection is p referred. requirements u 30V operating voltage u Fast time-to-trip u RoHS compliant, Lead-Free and Halogen-Free u Power ports u Motor protection u Automotive application u USB hubs ,ports and peripherals u General electronics Maximum Time To Trip Resistance Part Number I hold (A) I trip (A) V max (Vdc) I max (A) P dtyp. (W) Current (A) Time (Sec.) R min (m Ω) R max (m Ω) R 1max (m Ω) UN30-040 0.40 0.8 30 40 0.45 1.20 10 360 800 1200 UN30-050 0.50 1.0 30 40 0.50 1.50 10 270 600 900 UN30-065 0.65 1.3 30 40 0.50 1.95 10 160 360 540 UN30-075 0.75 1.5 30 40 0.55 2.25 10 135 300 450 UN30-090 0.90 1.8 30 40 0.60 2.70 12 110 220 330 UN30-110 1.10 2.2 30 40 0.70 3.30 12 85 170 230 UN30-135 1.35 2.7 30 40 0.80 4.05 12 65 130 165 UN30-160 1.60 3.2 30 40 0.90 4.80 15 55 110 140 UN30-185 1.85 3.7 30 40 1.00 5.55 15 45 90 115 UN30-200 2.00 4.0 30 40 1.10 6.00 15 40 80 100 UN30-250 2.50 5.0 30 40 1.20 7.50 15 35 70 90 UN30-300 3.0 6.0 30 100 2.00 9.00 15 30 60 75 UN30-400 4.0 8.0 30 100 2.50 12.0 15 20 40 50 UN30-500 5.0 10.0 30 100 3.00 15.0 20 15 30 40 UN30-600 6.0 12.0 30 100 3.50 18.0 20 12 24 30 UN30-700 7.0 14.0 30 100 3.80 21.0 25 10 20 25 UN30-800 8.0 16.0 30 100 4.0 24.0 25 8.5 17 22 UN30-900 9.0 18.0 30 100 4.2 27.0 25 7 14 18 I hold = Hold current: maximum current device will pass without tripping in 25°C still air. I trip = Trip current: minimum current at which the device will trip in 25°C still air. V max = Maximum voltage device can withstand without damage at rated current (I max ) I max = Maximum fault current device can withstand without damage at rated voltage (V max ) P dtyp.= Power dissipated from device when in the tripped state at 25°C still air. R min = Minimum resistance of device in initial (un-soldered) state. R max = Maximum resistance of device in initial (un-soldered) state. R 1max = Maximum resistance of device at 25°C measured one hour after tripping. Caution: Operation beyond the speci ?ed rating may result in damage and possible arcing and flame.