TW1251G-C3AL-NT_V0.02_Optical Modules Test Report

Optical Modules Test Report

Revision history

Table of Contents

1Summary (4)

1.1Basic Information (4)

1.2Test Equipment (4)

2Test conclusion (4)

2.1Overall conclusion (4)

3Test method (4)

3.1TX characteristic test method (4)

3.2RX characteristic test method (4)

3.3RX characteristic test required (5)

4BUG list (5)

5Test Results (5)

5.1Test data (5)

5.2Test Waveform (7)

6Thermal test (12)

7Environment-climate (14)

7.1Requirement (14)

7.2Determinant (14)

7.3Configure map (14)

7.4Operation cold Test (14)

7.5Operation Dry Heat High temperature test (15)

7.6Operation temperature cycle test (16)

Content 1 Summary

1.1Basic Information

1.2Test Equipment

2 Test conclusion

2.1Overall conclusion

3 Test method

3.1TX characteristic test method

3.2RX characteristic test method

3.3RX characteristic test required

The basic optical sources under the condition:

Eye graph of light source 4 BUG list

5 Test Results

5.1Test data

5.2 Test Waveform

1) TX Waveform in low temperature (Tc=0℃ V=3.13V)

2) TX Waveform in low temperature (Tc=0℃ V=3.47V)

3)TX Waveform in room temperature (Tc= 25℃V=3.3V)

4)TX Waveform in room temperature (Tc= 70℃V=3.13V)

5)TX Waveform in room temperature (Tc= 70℃V=3.47V)

6)TX Spectrum low temperature (Tc=0℃V=3.13V)

7)TX Spectrum low temperature (Tc=0℃V=3.47V)

8)TX Spectrum in room temperature (Tc=25℃V=3.3V)

9)TX Spectrum in room temperature (Tc=70℃V=3.13V)

10)TX Spectrum in room temperature (Tc=70℃V=3.47V)

6 Thermal test

1)Requirements

A sustained and steady temperature sample environment, the full-load running time T (power consumption less than 15W, testing time at least 4 hours; power consumption 15 ~ 30W, testing time at least 6 hours; 30 ~ 50W, testing time at least 9 hours; other specification recommends testing 24 hours).

2)Test method

Test the key Component center and top surface temperature. the key component contain CPU、PCBA and every thermal source area, the surface include Top、bottom,DUT on full load at least 4 Hours(or longer time) and be set in the box at 70℃(as shown).

3)Test point

①Key component

4)Test data(First time)

7 Environment-climate

7.1 Requirement

1) Environmental testing, To ensure that the hardware version and software version of the samples meet test

requirements, test sample at least 1pcs;

2) Conditional test, to ensure that the samples at room temperature (room temperature: air temperature

25 ℃ or so) under the conditions without exception;

3) Test requirements as far as possible in order to achieve the following order: low temperature test work -

the work of testing high-temperature - high and low temperature cycling test ;

4) The high-low temperature cycle test, you must work to ensure that high-temperature and low temperature

test work be carried out without exception; 7.2 Determinant

1)

During throughput test process, if one item is fail, the whole throughput test is recognized as fail; 2) Throughout the trial process, if have one item fail, determinant it FAIL;

3) According to different customers can refer to the different test standards such as EN 300 019-2-3,

IEC60068, GB2423, etc., no specific requirements in accordance with internal standards. 7.3 Configure map

1) Upstream set 95% of LAN stream, Set Downstream 95% DSL/PON stream. 7.4 Operation cold Test 1) Test condition

Temperature:-15℃,Humidity: Uncontrolled, Test time: t1=242Hrs , Sample Number: 1PCS

25

TL

2) Test data(First time)

7.5 Operation Dry Heat High temperature test 1) Test condition

Temperature: TH=55℃,Humidity: Uncontrolled, Test time: t1=24Hrs , Sample Number: 1PCS

25TH

2)

Test data(First time)

7.6Operation temperature cycle test

1)Test condition

Temperature: TL=-15;TH=55℃,Humidity: Uncontrolled, Test time:t1=3Hrs, Sample Number: 1PCS

25

TH

Temperature cycle TL

2)Test data(First time)

相关文档