英文版智能巡检仪说明书

英文版智能巡检仪说明书
英文版智能巡检仪说明书

1. Summary

YK-19 series intelligent Channels Measurement instrument is intelligent, high accuracy controller for temperature, pressure or level measurement. When use it to equipped with temperature, pressure or level sensor, we can consist temperature, pressure or level measurement control system for various type and range. provide

RS232 or RS485 to communication with computer or PLC。The instrument has a real-time clock for user get date and time。

2.T echnical specifications

Input signal: Resistance temperature Detector Pt100, Cu50, Cu100,3 wires conncet

Measurement accuracy : 0.2%FS±1 digit

Alarm Output: buzzer

communication: isolation RS485, baud 1200~9600bps。

transmit: isolation 4-20mA for the first channel,<250Ω

Display : double 4 digit LED display.

Power suply: 220V AC.

Power c onsumption: 2W

Temperature: 0~50℃

Ambient humidity: <85%RH

Front panel dimension : 160mm×80mm

Installation dimension : 152mm×76mm

3. Operation

Key-press Description

Press the KEY to mute the Buzzer.

at setting parameters state, press the key return to work state. At work

state, press the key to switch cycle display and static display. While at cycle display state,the bottom LED are display –xx-, at static display

Press the SET key to enter setting status.,After chang the current parameter

at setting parameters state, press ▲key making parameter increase one.

and hold the ▲key, value will increase or decrease quickly and release for stop. At static display state, press ▲key will change to next channels value display.

at setting parameters state, press▼key making parameter decrease one. and hold the ▼key, value wil decrease quickly and release for stop. At static display state, press the key will change to next channels value display.

After power on the display window displays HELO to indicate self-checking is right, displays -HH- indicates input over range or sensor disconnection or short-circuit. Instrument adopts man to machine talk model for input parameter, and use various prompting to indicate what kind of data should input. At the work state, the up LED display measured value,the bottom LED display the number of the corresponding channel.The last two are the date(-Ht-) and time(-Lt-).

(1)press the En key, the up display window displays –Cd-,bottom LED will display 800, Only 800 is changed to 808, and then press En key again will make the instrument to access the setup parameter setting status, other value is denied for preventing field operators from set parameters incorrectly by mistake.

(2) -LP-: the instrument measuring the number of channels,rang:1~16, Factory default 10.

(3)1-Sn:the first channel intput sensor type,Reference the table below,Factory default P100.

Rang 0-3,Factory default 1.

(5)1-PL: the 1st channel lower range value, only for the first,it is lower range value for the transmitter output too.

(6)1-PH: the 1st channel higher range value, only for the first,it is higher range value for the transmitter output too. For example,1-PL=0.0,1-PH=300.0, first channel measured value is150.0,then the output 4-20mA value is 12.0mA.

(7)2-Sn:the 2nc channel intput sensor type.

……

(8)1-HA: the 1st channel ultra-high alarm value.

(9)1-LA: the 1st channel ultra-low alarm value.

……

(10)1-Eo: the 1st channel measured value deviation rectify.ex: actual the 1st value is 30.0, currently display value is 29.2,then the parameter 1-Eo=0.8.Factory default 0.0 (11)2-Eo: the 2nd channel measured value deviation rectify.

……

(12)Addr:the communication address for computer, rang 01~99。Factory default 1

(13)baud:the communication baud for computer, 1200、2400、4800、9600 four items for choice。Factory default 9600.

(14)-Ht-: Current clock date, rang 1.01~12.31.

(15)-Lt-: Current clock time, rang 0:00~23.59.

(16)tS—the cycle display interval, unit second, rang 1~9999,Factory default 5

After parameter sets are finished, LED will display End and then go to working status.

4. Communication specifications

The instrument has RS485 interface, direct communication with the computer.

RS485 standard communication distance 1.5km, Can be connected to multiple devices/ instrument.Data character format is 1 initial bit , 8 data bits, 1 stop bit, no parity bit.

The instrument using modbus-rtu standard communication protocols,using 3x or 4x. Register addres from 1 to 18.

4x001 1 ch value

4x002 2 ch value

……

4x016 16 ch value

4x017 clock date

4x018 clock time

EX:the parameter Addr=1,the 1 channel value=100.0

host send query message: 01 03 00 00 00 01 84 0A.

Instrument return data: 01 03 02 03 E8 B8 FA.(0x03e8=1000)

5. T erminal wiring

recommended 6 months energized the 24-hour clock battery charging.

智能巡检仪说明书

智能巡检仪 使用说明书 江苏中科仪表有限公司智能巡检仪

目 一、智能巡检仪表性能特点 (2) 二、技术指标 (2) 三、仪表参数设置 (5) 四、仪表接线方法 (13)

概述 本系列智能数字巡检仪表采用专用的集成仪表芯片,测量输入及变送输出采用数字校正及自校准技术,测量精确稳定,消除了温漂和时漂引起的测量误差。本系列仪表采用了表面贴装工艺,并设计了多重保护和隔离设计,并通过EMC电磁兼容性测试,抗干扰能力强、可靠性高,具有很高的性价比。 本系列智能数字巡检仪表具有多类型输入可编程功能,一台仪表可以配接不同的输入信号(热电偶/热电阻/线性电压/线性电流/线性电阻/频率等), 同时显示量程、报警控制等可由用户现场设置,可与各类传感器、变送器配合使用,实现对温度、压力、液位、容量、力等物理量的测量显示、调节、报警控制、数据采集和记录,其适用范围非常广泛。 智能数字显示仪表以双排四位LED显示测量值(PV)和通道值(CH),以双色发光管进行各个通道测量值报警显示,还具有零点和满度修正、冷端补偿、数字滤波、通讯接口、多种报警方式,可选配继电器报警输出,还可选配变送输出,或标准通讯接口(RS485或RS232C)输出等。

一、智能巡检仪性能特点 1、专用的集成仪表芯片,具备更为可靠的抗干扰性及稳定性。 2、万能信号输入,通过菜单设置即可配接常用热工信号。 3、可在线菜单修改显示量程、变送输出范围、报警值及报警方式。 4、软、硬件结合的抗干扰模式,有效抑制现场干扰信号。 5、数字化校准技术,无电位器等可调部件。 6、热电偶冷端温度及热电阻引线电阻自动补偿。 7、可分别设置每一通道的测量量程及上下限报警值。 8、具有快速巡检和定点监视功能,巡检时间可设。 9、通过来自输入、输出及电源端的电磁兼容(EMC)测试。 二、技术指标: 1、显示方式:双排四位LED显示测量值(PV)和通道号(CH)。 2、显示范围:-1999~9999。 3、测量准确度:±0.2%FS±1字或0.5%FS±1字;±0.1%FS±1字(需特殊订制)。 4、显示量程和分辨率:各通道可根据需要分别设置显示范围和小数点位数; 5、输入信号:

直流屏检修及蓄电池活化手册

直流屏检修及蓄电池活化手册 直流屏)BDO(1.概述:BDO直流屏是选用艾默生网络资源有限公司研制开发的智能高频开关电力操作电源,由重庆斯拜迩科技有限公司全面生产和销售。 1.1设备规格型号名称、性能参数 1.1.1直流屏型号:标准一体柜GZDW33-60/220/10Y1; 电池型号:重庆安泰LCPA65-12,单支电池标称电压12V,电池容量65AH,共18支电池。 1.1.2性能参数 输入电压AC380V、电流AC24A; 输出电压DC220V、电流DC30A。 1.2设备结构简介(主要部件) 1.3系统工作原理及用途 1.3.1交流输入正常时:两路交流输入经过交流切换控制电路选择其中一路输入,并通过交流配电单元给各个充电模块供电。充电模块将三相交流电转换为DC220V,经隔离二极管隔离后输出,一方面给电池充电,另一方面给负载提供正常工作电流。监控部分对系统进行监控和控制,充电和馈电的运行参数、充电模块运行参数分别由配电监控和模块监控电路采集处理,然后把信息

上报给监控模块。. 1.3.2交流输入异常或停电时:充电模块停止工作,由电池给负载供电。监控模块检测电池电压,放电时间,当电池放电到设置的欠压点时,监控模块告警。交流输入正常后,充电电模块对电池充电。 2.直流屏的检修维护:由于直流屏在电力系统中的特殊性和重要性,在正常运行的情况下,直流屏不能停电进行检修,因此平时只能加强对仪器仪表的巡检工作。 2.1观察两段进线红灯是否亮起(正常情况应亮),故障黄灯是否熄灭(正常情况是熄灭); 2.2观察交流电源切换开关LW1是否打在“0”位(0位是自动切换位,1位是I路交流电源,2位是II路交流电源,正常情况下应该在0位); 2.3观察调压控制开关LW2是否打在“自动”位(正常情况下应该在自动位,0为是停止位,1位是手动短接1组硅链单元,降压单元的压降减小,2位是手动短接2组硅链单元,3位是手动短接3组硅链单元,4位是手动短接4组硅链单元,5位是手动短接5组硅链单元); 2.4观察C级和D级的防雷开关应该处与闭合位; 2.5观察监控模块显示信息的液晶显示屏,及指示模块工作情况的电源指示灯和告警指示灯(绿色的用来指示电源,当发生告警时,红色指示灯亮,同时模块内的蜂鸣器发出告警音。当屏幕反白显示表示该设备与监控模块的通讯中断。); 2.6充电模块面板上的LED显示的是输出电压或电流,由转换开关进行切换,面板中部的三个发光二极管分别指示:绿色是模块输入电源正常,黄色是模块保护动作(包括交流过/欠压,缺相,输出欠压等),红色是模块故障(包括输出过压)。在正常运行下,只有绿灯亮,黄/红灯应该是熄灭。在红灯旁边有一个电位器,它主要是在手动方式下调节充电模块的输出电压,由于该电位器可使充电模块的输出电压最高达到286V,因此在系统正常时请勿随意调整该电位器。在电位器旁边是充电模块的自动/手动选择开关,正常情况应打在自动位,旁边是地址选择开关,拨码向上拨是1,向下拨是0,它主要是决定充电模块与监控模块通讯时的二进址地址。 2.7观察绝缘检测仪电源指示灯,运行灯和告警灯(电源绿灯应常亮,运行绿灯应闪烁,告警红灯应熄灭); 2.8观看电池巡检仪上显示的电池电压是否正常(一般电池电压在12V—14V之间); 通过以上8条的观察,可以达到对直流屏的维护工作。同时也可以通过对微机通讯系统直流系统的报警信息判断直流屏是否正常工作。在大修中,可以使用吸尘器和毛刷进行屏柜的清洁卫生打扫。 3. 蓄电池的检修维护:直流屏的蓄电池在每一年的大修中,应该进行一次充/放电,达到检测电池容量和活化电池的效果。 3.1检修准备 3.1.1两套1000W碘钨灯,三套5欧放电板; 3.1.2安全隔离线,警示牌; 3.1.3 6块砖块,绝缘手套; 3.1.4充/放电纪录表和笔; 3.1.5拔电池保险的专用工具; 3.1.6人员2人,计划时间2天。 3.2危险因素 3.2.1碘钨灯和放电板都是高发热元件,注意烫伤; 3.2.2直流屏在吹扫和紧固端子时是带电作业,因此要注意触电伤人; 3.2.3过放电会损坏电池,注意坏电池的回收或电解液流出造成的环境污染。 3.3安全措施 严格办理并执行第二种工作票;3.3.1.

蓄电池巡检仪-使用说明

安全注意事项 操作安全 ●在使用本产品前,请仔细阅读“安全注意事项”,以确保正确和安全的使用: ●本产品的安装、接线和调试工作,请由其备一定电气安全知识的技术人员来完成; 电气安全 ●在安装和接线时,请按照安装接线图来操作; ●在接线时,严格区分“工作电源线”、"RS485通讯线”和“电池电压信号采集线”,以 避免损坏机器: ●接线时,注意先接好蓄电池巡检仪和电池巡检单元上的线,确认无误后,再拔除蓄电池 巡检仪和电池巡检单元上的接线端了排,再去接电池端了上的连接线; ●蓄电池组的编号顺序是从负极往正极编数,即蓄电池组负极端上的电池为第一节电池; ●在接电池端了上的连接线是,请注意电池的正负极性; ●上电前,请去人已经正确接地,“工作电源线”、“RS485通讯线”和“电池电压信号采 集线”正确无误后,再插上蓄电池巡检仪和电池巡检单元上的接线端子排,之后上电调试。 其他 本手册适用于KM-BU01蓄电池巡检仪和KM-BU02电池巡检单元产品; 1.概述 KM-BU01蓄电池巡检仪是为满足UPS、EPS、直流电源、通信电源等系统而设计的一款在线式蓄电池巡检仪。可完成对电池组电压、电池电流、单体电池电压、电池内阻、电池环境温度及电池放电计量等监测和告警功能。适用于对2V、6V、12V蓄电池进行在线监测。 KM-BU01蓄电池巡检仪自带24节电池巡检功能。每个测量端口均采用光藕进行隔离。另外。可通过扩展KM-BU02电池巡检单元实现120节电池巡检功能。内置标准RS485通讯接口。实现上位机通讯功能。

2.功能 ●单体电池监测具有过压、欠压和差压报警功能,准确查找故障电池。 ●检测单体电池电压、电池组端电压和电流、电池环境温度和测量单体电池内阻。 ●放电计量,记录放电电压、电流、放电容量和放电时间。 ●完善的故障报警功能。 ●开放式通讯协议设计,RS485串行通讯接口,支持1200BPS、2400BPS、4800BPS、9600BPS 波特率,实现遥测、遥信功能,可方便的与电力自动化系统对接,实现电池系统自动巡检。 ●系统对故障信息提供继电器常开触点输出。 ●可按现场实际情况设定巡检电池节数并接线,如18节时只需完成BAT00至BAT18接线, 当超过24节电池时,需通过485通讯接口扩展电池巡检单元。 3.特点 ●可通过扩展电池巡检单元。实现120节单体电池电压采集功能。 ●最多可监测4组独立的蓄电池组。 ●配置灵活、操作简单。 ●每个电池电压测量端口均采用光藕进行隔离确保系统安全稳定运行。

智能巡更巡检管理系统操作

智能巡更巡检管理系统 操作 Document number:BGCG-0857-BTDO-0089-2022

前言 感谢您使用我们的“智能巡更巡检管理系统”。本手册适用于:智能巡更巡检管理系统系列。 郑重声明 未经本公司许可,本手册及软件的任何部分不得以任何方式复制或抄袭。 因使用不当引起的损失,本公司概不承担任何责任。为了您能正确地设置和使用本系统并得到最佳性能,保证长期使用,请必须仔细阅读本操作手册。 因技术发展,本公司保留未经通告而变更本手册、软件及硬件产品性能指标的权利。 使用时请注意爱护产品,这是延长其寿命的最好方法。 系统特点 软件是一款简单、实用的巡更巡检管理系统,仅需设置地点、人员或计划(可选)便可使用,而且使用过程中数据的分析、存贮、备份都由软件自动完成。软件所需的售后服务量极少,因此又称“零售后服务软件”。 智能巡检计划 对巡检线路即可设置计划,也可不设置计划,都可以分析出巡检结果。 灵活设置人员、事件

如果要掌握巡检人员情况,可为每个人员配备电子标签(卡式),在软件中进行相应的设置即可,在巡检前先读人员卡,再去巡检,系统自动识别,此项为可选设置(无计划模式为必选项)。 系统也同样支持事件,事件可由两种方法实现:一种是在巡检器上选择(事件代码),另一种是使用事件卡,事件处理由软件自动分析识别。 免维护 自动完成数据月备份、周备份和即时备份,自动清除过期数据。

快速上手指南 初次使用本软件,可按如下步骤进行设置: 1.巡检地点管理中进行线路和地点设置; 2.如果巡检过程需要进行人员身份识别应设置巡检人员,为每班组或个人设 置人员卡;如采用无计划模式必需设置人员卡。 3.(可选设置)如巡检过程需要记录事件,请设置巡检事件,事件支持编码 方式和事件卡方式; 4.制定巡检计划。注可为巡检线路设置巡检计划。(可选设置) 5.在系统参数中,正确设置巡检器通讯所用的端口。 6.读取巡检数据时请正确选择所使用的巡检器型号。读取数据后软件会自动 保存并分析数据; 7.初次使用时,如不能查询巡检结果,请使用菜单中巡检数据->重新分析功 能,此功能仅对设置了巡检计划的线路有效。 电子标签安装流程 第一步:划分巡检线路 确定被巡检范围需要设置几条巡检线路,每条线路应安装多少个点 例如:需要设置2条线路A线和B线,A线路45个电子标签,B线路35个电子标签。在“资源管理”菜单中点击“巡检地点管理”功能 模块中,点击左下角的“增加”按钮,即可增加巡检线路。 第二步:手工编号 把不同线路的电子标签分开,贴上不干胶标签,并标上序号,如 1、2、3……,并且不要打乱已编完序号电子标签的顺序。

DQU_DC28_G_电池采集器说明

DQU_DC28(G) 电池采集器技术说明书 w w w . n j k e j i n . c n 南京科进自动化有限公司

一、概述 用于监测蓄电池组的每节电池的端电压。以及机房温度、湿度、等机房环境量。提供了28个遥测量(模拟量)。 二、外形 图1.外形图 1. 液晶显示屏 2. 工作显示灯(VCC :电源灯;RXD :通信接收灯;TXD :通信发送灯; RUN :运行灯) 3. 工作电源输入端 4. 按键:“▲”上行键;“▼”下行键 ;“■”执行键 5. 遥测输入端子 6. 通信连接端子 1 2 3 4 5 6

三、技术指标 3.1监测量 a)模拟量:28个模拟量(24个电池量,4个直流量); 3.2指标: a) 直流电压量: 测量范围-5V +5V (2.5V直流条件下) 精度 0.5% b)通信接口: 电气接口(国际标准) RS485或RS232 通信方式串行半双工 速率300、600、1200、2400、4800、9600、19200bps 数据格式N.8.1 连接方式全分布式,总线接口 规约DQU规约 c)供电电源: 电源电压-48 V (直流) d)环境条件: 温度条件0-45℃ 湿度条件10-90% 四、工作原理 DQU—DC28(O)由大规模集成芯片组成,包括:状态量光隔接口,模拟电接口,中央处理器,串行通信接口,电源等几大部分组成,其组成框图见图2。

图2.DQU-DC28(G)数据采集器原理框图 工作时中央处理器(CPU)不断循环采集各信号接口输入的信号,运算、存储。当上级计算机发来命令,将采集存储的数据以串行方式全部送出,实时数据送到中心站显示。 DQU—DC28(G)串行接口可以有两种工作方式。可被设定为RS-485接口。如果实际需要RS-232接口时,可以通过更换跳线进行设置,使通信接口变为RS-232口。 4.1模拟量接口 1) DQU-DC:隔离平衡直流模拟量(工作电源必须是隔离电源) 模拟量直接采样处理,差模电源必须在0~15V之内。 图3(a)YC0-23电池采样 图3(b)YC24-27直流采样

NHR-5700系列多回路温度巡检仪使用说明书

版本号:5700-130601 NHR-5700系列多回路数字显示控制仪使用说明书 一、概述 NHR-5700系列多回路数字显示控制仪采用了表面贴装工艺,全自动贴片机生产,具有很强的抗干扰能力。本仪表支持多种信号类型输入,可与各类传感器、变送器配套使用,实现对温度、压力、液位、速度、力等物理量的测量显示,可巡回检测8~16路测量信号,带8路或16路“统一报警输出”、“16路分别报警输出”、统一变送输出”、“8路分别变送输出”功能、485/232通讯等输出功能,适用于需要进行多测量点巡回检测的系统。 二、技术参数 输入 输入信号电流电压电阻电偶 输入阻抗≤250Ω≥500KΩ 输入电流最大限制30mA 输入电压最大限制<6V 输出 输出信号电流电压继电器24V配电或馈电输出时允许负载≤500Ω≥250 KΩ (注:需要更高负载能力时须更换 模块) AC220V/2A DC24V/2A ≤30mA 综合参数 测量精度0.2%FS±1字 设定方式面板轻触式按键数字设定;参数设定值密码锁定;设定值断电永久保存。 显示方式-1999~9999测量值显示、设定值显示,发光二级管工作状态显示 使用环境环境温度:0~50℃;相对湿度:≤85%RH;避免强腐蚀气体。 工作电源AC 100~240V(开关电源)(50-60HZ);DC 20~29V (开关电源)。 功耗≤4W 结构标准卡入式 通讯采用标准MODBUS通讯协议,RS-485通讯距离可达1公里;RS-232通讯距离可达:15米。 注:仪表带通讯功能时,通讯转换器最好选用有源转换器 三、仪表的面板及显示功能 1 外形尺寸开孔尺寸 160*80mm(横式)152*76mm 80*160mm(竖式)76*152mm 96*96mm(方式)92*92mm 2)显示窗 PV显示窗:显示测量值;在参数设定状态下,显示参数符号 SV显示窗:显示通道数;在参数设定状态下,显示设定参数值

英文版智能巡检仪说明书

1. Summary YK-19 series intelligent Channels Measurement instrument is intelligent, high accuracy controller for temperature, pressure or level measurement. When use it to equipped with temperature, pressure or level sensor, we can consist temperature, pressure or level measurement control system for various type and range. provide RS232 or RS485 to communication with computer or PLC。The instrument has a real-time clock for user get date and time。 2.T echnical specifications Input signal: Resistance temperature Detector Pt100, Cu50, Cu100,3 wires conncet Measurement accuracy : 0.2%FS±1 digit Alarm Output: buzzer communication: isolation RS485, baud 1200~9600bps。 transmit: isolation 4-20mA for the first channel,<250Ω Display : double 4 digit LED display. Power suply: 220V AC. Power c onsumption: 2W Temperature: 0~50℃ Ambient humidity: <85%RH Front panel dimension : 160mm×80mm Installation dimension : 152mm×76mm 3. Operation Key-press Description Press the KEY to mute the Buzzer. at setting parameters state, press the key return to work state. At work state, press the key to switch cycle display and static display. While at cycle display state,the bottom LED are display –xx-, at static display 。 Press the SET key to enter setting status.,After chang the current parameter at setting parameters state, press ▲key making parameter increase one. and hold the ▲key, value will increase or decrease quickly and release for stop. At static display state, press ▲key will change to next channels value display. at setting parameters state, press▼key making parameter decrease one. and hold the ▼key, value wil decrease quickly and release for stop. At static display state, press the key will change to next channels value display.

巡检仪使用说明书(无校准)

16通道智能巡检仪使用说明书 特点: 1、1-16通道数可选择(即可屏蔽2-16通道中的任何一个通道); 2、各通道输入类型可任意设置(通过软件设置和硬件跳线相结合的方式完成); 3、各通道可根据需要分别设置小数点位置和显示范围; 4、多种报警方式可选择:16通道相同输入类型情况下可实现集中设置报警值统一继电器输出、独立设置报警值统一继电器输出、独立设置报警值独立继电器输出;16通道不同输入类型情况下可实现独立设置报警值统一继电器输出、独立设置报警值独立继电器输出;分别报警由副机完成; 5、多种变送输出类型和方式可选择:可选择输出0-10mA、0-20mA、4-20mA信号;可选择所有通道测量值的平均值、最大值、最小值变送输出;可指定16通道中任何一通道进行变送输出;所有输出方式的变送范围均可设置; 6、采用双排四位数码管显示方式,每通道采用双色指示灯指示报警状态,红色亮表示上限报警,绿色亮表示下限报警; 7、具备手动巡检功能,可手动查看各通道测量值; 8、具备485通讯输出,采用标准modbus协议,通用性强,可靠性高; 设置方式: 长按SET键(2秒)即可进入设置菜单,增加键∧、减小键∨修改参数值,SET键确认并保存参数值,同时跳至下一菜单,按MAN键可回到上一个参数,同时按SET键和MAN键即可退出设置状态;在设置状态下如50秒无按键操作,即自动退回测量状态; 参数设置表

Sn代码表: [表二 报警指示:在巡检仪面板上有16只双色指示灯,用于各通道报警状态显示,即任意通道有上限报警信号时,其对应通道的指示灯红灯亮,统一报警时上限报警继电器吸合,分别报警时对应通道的上限报警继电器吸合;有下限报警信号时,对应通道的指示灯绿灯亮,统一报警时下限报警继电器吸合,分别报警时对应通道的下限报警继电器吸合,若没有报警信号则指示灯不指示。 统一报警时,16通道中任何一通道进入报警状态,即相应的报警继电器吸合,例如第2通道有上限报警信号时,仪表上限报警继电器即吸合,如果有多个通道同时有报警信号存在,则只有当所有通道的报警信号解除后相应的继电器才释放。 分别报警时,任何一通道有报警信号,则主机上由双色指示灯指示其报警状态(红色为上限报警,绿色为下限报警),由副机实现继电器动作过程。

蓝卡《智能巡逻管理系统》使用说明书

《智能巡逻06管理系统》使用说明书 1、系统简介 电子巡逻巡检系统是监督考核巡逻人员工作情况的智能管理系统,由感应式智能巡逻管理系统软件、巡检器和各种射频卡构成。其基本的原理就是在巡逻线路上安装一系列代表不同地点的射频卡(又称感应卡),巡逻到各点时巡逻人员用手持式巡检器(相当于刷卡机)读卡,把代表该点的“卡号”和“读卡时间”同时记录下来。巡逻完成后巡检器通过通讯线把数据传给计算机软件处理,就可以对巡逻情况(地点、时间等)进行记录和考核。 《智能巡逻06管理系统》06版本是一个综合性软件,此软件可以适用于我公司生产BP -2002、BP-2002B、BP-2002V、BP-2002S、BP-2002W巡检器及BS-1000通讯座、BS -2000数据采集器、BS-3000短信通讯座、BS-4000及BS-4000m通讯座。同时也能使用BS-1000t的通讯座。 1.1、如何安装系统 执行程序“感应式智能巡逻管理系统”,根据安装提示向导完成。 在安装过程中,系统会提示是否安装USB驱动,点击“Install”完成USB安装。 图1:驱动安装提示图 操作系统要求:win2000,winXP,或更高版本的windows系统。 计算机硬件要求:主频1.5G以上、内存128M以上、硬盘5G以上,带光驱,至少一个USB接口。建议使用计算机的配置要高于以上要求。 1.2、巡检点的安装 巡检点的安装:巡检点卡为标准的ID卡,每一张卡都有全球唯一的16进制卡号,每张卡的卡号代表一个检查点,一般埋入墙内防破坏,深度小于5毫米左右,管型卡安装比较方便。具体安装方法请参考光盘附带的《巡检点安装说明》。

智能巡检管理系统的设计与解决方案

智能巡检管理系统方案说明书 文档号:FZSS-NTS -01 编制:郑梅娇 审核:蒋伟 审批:蒋兴钉 2014年06月23日 顺生信息技术有限公司?2014 All Rights Reserved

目录 1概述 (1) 2总体思想 (1) 项目背景 (1) 系统现状 (4) 建设目标 (4) 总体原则 (9) 3后台软件解决方案 (10) 平台选型 (10) 系统构成结构图 (12) 智能巡检管理系统功能 (12) 系统管理 (19) 权限管理 (19) 报表管理 (19) 4手机部分 (20) 手机部分软件功能 (20) 手机部分硬件功能 (22) 5识别卡和条形码 (23) 6进度安排预计 (24) 7报价 (26) 软件报价表 (26) 硬件报价表 (26) 总报价表 (27)

?概述 本方案是顺生信息技术有限公司按贵司的要求,在商讨了基本需求的基础上,结合顺生信息公司多年从事企业信息化和开发的经验,而为智能巡检管理系统方案。目的是使负责智能巡检管理系统的领导和专家能充分了解整个系统的设计思路和总体思想,为总体功能定义、技术平台确定等提供帮助。 ?总体思想 本方案主要是智能巡检管理系统提供详细的解决方案。 项目背景 工程概况 水电站枢纽为拱坝+引水隧洞+地面厂房布置形式。大坝为抛物线型混凝土双曲拱坝,最大坝高108m;引水隧洞总长约7km,调压井总高度约175m;电站共装二台混流式水轮发电机组,单机容量50MW,总装机容量100MW。 工程于2002年12月26日开工,2003年9月29日工程截流,2005年11月2日水库通过福建省经贸委主持的蓄水验收,11月18日水库下闸蓄水,12月27日首台机组投产发电。 电厂现状 目前牛头山水电站电厂运行人员和维护人员采用巡检管理系统,巡检管理系统已使用多年,设备老化,因现在智能巡检仪设备在不断更新换代,为适应现在电厂先进管理化,提出改造智能巡检管理系统。

智能巡检管理系统V3.5.7软件说明书

智能巡检管理系统V3.5.7软件使用说明书 服务源于诚信品质源于专业

目录 第一章软件安装 (2) 1.1 软件运行环境要求 (2) 1.2 如何安装软件系统 (2) 1.3 如何卸载软件 (2) 1.4 系统登录 (3) 第二章基础信息 (4) 2.1 设置巡检线路 (4) 2.2 设置巡检地点 (5) 2.3 巡检线路与地点绑定 (8) 2.4 设置巡检人员 (10) 2.5 设置巡检器号码 (10) 2.6 巡检计划排班设置 (11) 第三章数据处理 (14) 3.1 读取巡检器数据 (14) 2.2 巡检情况查询 (15) 3.3 原始记录查询 (16) 3.4 合格率统计 (17) 3.5 重新分析数据 (17) 第四章系统维护 (18) 4.1 巡检器设置 (18) 4.2 数据库初始化 (19) 4.3 恢复数据 (19) 4.4 清理巡检数据 (20) 第五章可能遇到的问题和解决方法 (21) 5.1 软件安装完成后找不到巡检器,无法上传数据 (21) 5.2 USB驱动已正确安装,还是无法上传数据 (24) 5.3 原来可以上传数据,软件系统突然读不了数据了 (25)

第一章软件安装 1.1 软件运行环境要求 计算机硬件推荐配置:当前主流兼容机均可满足要求。建议CPU:P4 1.7G以上,内存:512M,硬盘空间:10G以上。 WINDOWS操作系统平台,推荐采用WINDOWS XP/2000操作系统。 1.2 如何安装软件系统 运行软件光盘中的智能巡检管理系统V3.5.7.EXE文件,依据提示完成安装。 应用程序安装结束时请选择Install安装USB 驱动程序,如果省略此安装步骤,系统将无法读取巡检器数据。 1.3 如何卸载软件 在系统“开始”—“程序”—“智能巡检管理系统V3.5.7”中选择“卸载智能巡检管理系统V3.5.7”即可。 建议您只使用上述方法卸载本软件,其它方法可能造成系统运行故障。

智能巡检管理系统的设计解决方案

智能巡检管理系统 案说明书 文档号:FZSS-NTS -01 编制:梅娇 审核:伟 审批:兴钉 2014年06月23日 顺生信息技术有限公司2014 All Rights Reserved

目录 1概述 (1) 2总体思想 (1) 2.1项目背景 (1) 2.2系统现状 (4) 2.3建设目标 (4) 2.4总体原则 (9) 3后台软件解决案 (10) 3.1平台选型 (10) 3.2系统构成结构图 (12) 3.3智能巡检管理系统功能 (12) 3.4系统管理 (19) 3.5权限管理 (19) 3.6报表管理 (19) 4手机部分 (20) 4.1手机部分软件功能 (20) 4.1手机部分硬件功能 (22) 5识别卡和条形码 (23) 6进度安排预计 (24) 7报价 (26) 7.1软件报价表 (26) 7.2硬件报价表 (26) 7.3总报价表 (27)

概述 本案是顺生信息技术有限公司按贵司的要求,在商讨了基本需求的基础上,结合顺生信息公司多年从事企业信息化和开发的经验,而为智能巡检管理系统案。目的是使负责智能巡检管理系统的领导和专家能充分了解整个系统的设计思路和总体思想,为总体功能定义、技术平台确定等提供帮助。 总体思想 本案主要是智能巡检管理系统提供详细的解决案。 2.1项目背景 工程概况 水电站枢纽为拱坝+引水隧洞+地面厂房布置形式。大坝为抛物线型混凝土双曲拱坝,最大坝高108m;引水隧洞总长约7km,调压井总高度约175m;电站共装二台混流式水轮发电机组,单机容量50MW,总装机容量100MW。 工程于2002年12月26日开工,2003年9月29日工程截流,2005年11月2日水库通过省经贸委主持的蓄水验收,11月18日水库下闸蓄水,12月27日首台机组投产发电。 电厂现状 目前牛头山水电站电厂运行人员和维护人员采用巡检管理系统,巡检管理系统已使用多年,设备老化,因现在智能巡检仪设备在不断更新换代,为适应现在电厂先进管理化,提出改造智能巡检管理系统。

BATM30巡检模块使用说明

BA TM30型蓄电池组巡检仪 使用说明书 一、工作原理 BA TM30系列蓄电池巡检模块由微电脑控制,采用串行总线方式,通过RS232(电流环型)通迅接口与上位机集中监控器相连接,实时检测蓄电池组的单节电池电压、环境温度,并将检测到的数据初步处理后上传至集中监控器,由监控器对所接收的数据进行分析处理。 二、型号命名 蓄电池组单节电池额定电压 BA TM30系列蓄电池巡检仪 三、功能特点 ?采用模块化设计,各模块独立工作,单模块可采集18节电池的电压、环境温度。 ?可根据电池节数按需配置巡检模块的数量,同一组巡检模块以地址区分。 ?各模块具有独立的隔离电源,输入电源范围宽(DC90V~DC270V)。 ?能够检测2V、6V和12V等多种等级的蓄电池,检测范围广 三、技术参数 环境温度:-10℃~+40℃ 相对湿度:≤90% 环境磁场:<400A/m 大气压:80-107kPa 工作电源范围:DC80V~DC286V 可测量蓄电池电压等级:2V、6V、12V 电压检测精度:±0.5% 温度检测范围:-50℃~100℃ 温度检测精度:±0.5℃ 数据采集时间间隔:30 S 通迅接口:RS232(电流环型) 通迅波特率:1200bps 功率消耗:<1W 重量: 四、安装使用说明 4.1接线 巡检模块组合接线图如下:

4.2地址拔码说明 地址拔码的作用是区分巡检模块的地址。 如下所示拔码开关的左边为高位,右边为低位,拔向数字端表示1。 1 2 3 4左图表示地址码为3 二进制表示 0011B 1 2 3 4在图表示地址码为11二进制表示1011B 注:如果监控器为本公司产品,监控器控多组巡检模块,监控器默认的地址分配如下: ①第一组巡检模块地址从0开始,依次为0,1,2,3,4,5,6 ②第二组巡检模块地址从7开始,依次为7,8,9,10,11,12,13 ③第三组巡检模块地址从14开始,依次为14,15 4.3使用说明 对照接线示意图,准确连接好所有的连线。 正常运行时,运行指示灯(绿灯)亮,每巡检一个周期后运行指示灯闪烁一次;与监控器通迅时通迅指示灯(红灯)亮,每通迅一次整组巡检模块的通迅指示灯依次闪烁一次。 使用中可能遇到如下问题: 1.运行指示灯不亮 可能原因:①工作电源回路接线不良或极性接反,重新接线。 ②巡检模块内部电路故障,通知厂家维修。 2.通迅指示灯不亮 可能原因:①通迅回路接线不良或发送、接收端接反,重新接线。 ②通迅接口部分电路故障,通知厂家维修

多路温度巡检仪操作规程

文件编号 JK-1008U多路温度巡检仪操作规程版本/修订A/0 一操作说明: 1.突出通道显示设置:按右方向键组号或通道号闪烁,上下键修改通道,再按右方向键或等待几秒后停止闪烁,退出设置; 2.切换显示内容:大号字体显示时,修改突出显示的通道号,可切换到另一组温度显示。小号字体显示时,配置多余4组的情况下,按上下键切换到下一屏; 3.菜单操作:按“菜单”键进入设置菜单,按方向键选择需要设置的项,按“菜单”键进入该项的设置:左右键选择设置项;上下键修改设置项;“确认”键保存设置项;“返回”项:返回上级菜单;“退出”:退出设置,返回到温度显示窗口;闪烁显示项:表示该项为待设置项:按“菜单”键进入该项或者该项的子编辑项 4.组/通道开关:上下键选择组,按“菜单”键进入设置改组/通道的开关,上下键设置开关,按“菜单”键返回上一级 5.温度上下限:最多可设置8个温度上下限,分别用于不同的通道,但各温限之间有包含覆盖功能 5.1温限1:上下键修改温限号,“菜单”键进入设置改组的开关,上下键设置开关,按“菜单”键返回上一级; 5.2应用范围:按“菜单”键选择应用范围,上下键选择,“菜单”键进入设定,左右键切换组/通道设置,上下键选择第几组或第几通道,“菜单”键返回上一级 5.3.上限,下限:按“菜单”键进入设定温限数值,左右键选择要修改的位,上下键修改该位的数值。温度上限要大于下限。 6.存储设置: 6.1存储类型:上下键选择存储类型,显示已用存储空间百分比;

6.2间隔:存储时间间隔最大可设置9时59分59秒;按“菜单”键进入时间间隔设定,按方向键修改数值;巡检时间间隔最小为N*1.5秒,N为配置组数;定点间隔最小为1S 6.3注意: A.U盘存储过程中,若想取下U盘,先按左方向键,防止数据丢失; B.每次开始存储,仪器将删除上次存储的信息,请拷贝防止数据丢失; 7.热电偶型号:JK-8U最多可配置8组,每组热电偶的型号可以不同,可以选择K,J,T 三种型号的热电偶,未配置热电偶的组显示为“—” 8.热电偶检测:主菜单中选择热电偶检测,按“菜单”键开始检测,检测结束后显示检测结果:前面是通道号,后面是组号 9.波特率:波特率需要根据上位机软件支持的波特率设置;上下键选择,左右键选择其他 10.温度选择:按方向键切换显示华氏/摄氏温标 11.时间设置:上下键选择设置项;按“菜单”键进入设置项,左右键选择位,上下键修改选择位;按“菜单”键返回上一级 12.仪器调试:(返回勿动) 13.注意事项: A.若个别通道出现测量异常,可通过仪器检测热电偶是否开路; B.环境温度-20-70℃ C.仪器周围不应有温度变换频换的温度源,影响仪器的测量准确度 D.热电偶相互之间的电位差不应超过300V

电池巡检仪

电池巡检仪 BAT系列电池巡检仪是一种针对电源系统蓄电池进行实时、完善的在线检测与管理的装置。安规和EMC符合CE认证指令。目前已广泛应用于电力、通讯、交通、汽车等相关行业的动力储能电池的管理中。 主要功能与特性: * 24节电池电压全隔离检测,保证测量稳定; * 配合本公司高精度电流传感器与温度传感器,可测量电池组充放电电流与两路电池环境温度; * 2V、6V、12V电池自动分档测量,全范围量程精度保证优于0.2级; * 模块化设计、扩展方便,可配置1~16个电池采集模块,实现1~384节电池的电压采集; * 可监测两组独立的电池,参数独立设置; * 电池电压采集速度快,单体采集速度达ms级,与放电模块配合可扩展内阻测试功能; * RS485通讯接口,标准MODBUS通讯规约; * 安规和EMC符合CE认证 性能指标: BAT2.2/BAT2.3电池巡检仪性能指标 功能项目参数参数范围等级指数备注

供电范围43~300VDC或36~250V AC 功耗<10W 工作环境温度-5~+50℃ 工作环境相对温度10%RH~90%RH 大气压70~106KPa 机械尺寸216mm×94mm×38.5mm 重量约620g 通信波特率1200、4800、9600、19200bps可设置 电池组总电压40~500V ±0.2% 电池单体电压累加所得电池组充放电电流根据实际参数配置变送器±1.0% 本公司提供直流电流变送器电池温度2路0~75℃±1℃本公司提供温度变送器电池单体电压0.05~16V ±0.2% 2V电池系统 ±0.2% 6V电池系统 ±0.1% 12V电池系统产品图片 相关产品接线方式

温度巡检仪说明书

TCD16/48温度巡检仪使用说明书 武汉华工电气自动化有限责任公司 2001年7月

一. 名称与编号 1.产品名称:16/48路数字温度巡检仪 2.产品型号:IET-TCD16/48 3.软件版本号:TCDV2.0 二. 用途与性能 1.用途: 数字温度巡检仪适用于电力、化工、石油、冶金及其它生产过程中,对传感器为热电阻的温度参数进行巡回检测、越限报警及参数显示。 2.性能: (1) (2)热电阻线制:①三线制②二线制,不配线路电阻 (3) 故障显示: ①热电阻空载显示----。 ②热电阻正溢出(过量程)显示HHHH。 ③热电阻负溢出显示LLLL。 (4) 测量精度:±0.5% (5)分辨率:热电阻0.1℃ (6)报警方式: 有测点越限时,点亮对应越限指示灯,同时吸合继电器,越下限或越上限1,接通越限报警继电器;越上限2,接通事故报警继电器。保持,直到所有测点回复正常,,熄灭越限指示灯,继电器返回。

三.硬件原理框图和软件流程图 图1 硬件原理图 图2 软件流程图 四.机箱外观视图 1.机箱在屏柜上开孔尺寸为(mm):202×86(宽×高),机箱尺寸如下图:Et Rt

2. 背视图 背视图说明: ① 32~47路信号线插头(孔) ② 16~31路信号线插头(孔) ③ 0~15路信号线插头(孔) ④ 报警输出插头(孔) ⑤ 通讯接口插头(针) ⑥ 电源开关 ⑦ 电源插座

3.正视图 正视图说明: ①点序位: 用于显示测点序00~47,整机设定点序为P0。 ②参数位: 用于显示分度号,线制,线路电阻,上限1、上限2、 下限报警值,温差等。 ③L0~L47 : 用于指示当前接有信号的通道。 ④工作状态功能指示灯,从左至右依次为: ·功能指示灯点序N: 闪烁为点序,平光为接入信号为热电阻测量信号。 ·功能指示灯分度S: 闪烁为分度。 ·功能指示灯线路电阻阻C: 当分度号是热电阻时,闪烁时可按“ ”或“ ”将某点线路电阻在参数位上显示出来。 ·上限1报警指示灯H1: 闪烁为设定报警值,平光为某点已越限。 ·上限2报警指示灯H2: 闪烁为设定报警值,平光为某点已越限。 ·下限报警指示灯L: 闪烁为设定报警值,平光为某点已越限。 ⑤按键区从左至右依次为:

智能巡检PDA巡更管理系统解决方案(GPS三合一方案)

GPS三合一电子巡更管理系统 解 决 方 案 时间:2016年8月30日

领导审查页 三合一电子巡更系统工程说明 序号 系统名称 系统预算 造价预算编制说明: 1:工程报价是根据国内一线品牌做 出的;所有设备都为工程机。单价含调 试费、施工费、设备2年维保费、税金、 运费、保险费、仓储费、搬运费、企业 管理费等,单位:元。 2:设备具有防爆功能。巡检记录、 拍照、事件和数据记录等功能。领导可以通过互联网查看各个站点的巡更记录。 3:中心机房机柜使用旧机柜,中心机房需要接入互联网,该项费用未计入本次预算。 4:工程质量标准:合格。 5:需要GPS 定位功能时,需要增加电话卡,该项费用未计入预算。 6:各站点需要具有WiFi 和电脑,电脑需要接入互联网,该项费用未计入预算。 1 电子巡更系统 1:各个站点设备配置:智能巡检器PDA :单台预算4000元;建议每个站点配置1-2台;巡更点25元/个,具体数量根据各个站点需求确定;安装调试费一项:1500元/个站 2:中心机房:安装一套网络巡更软件、数据库软件、客户端软件和服务器共55000元;安装调试费一项5000元。 工程预算总价(元) 造价工程师: 审核: 商务: 预算:

目录 前言 (4) 一、系统背景 (4) 二、GPS三合一电子巡更管理系统介绍 (5) 三、GPS实时巡更管理巡检系统管理平台的构成 (7) 四、解决的问题 (10) 五、GPS巡更拓扑图: (11) 六、配置清单: (12)

前言 “互联网+”让传统行业进入“智能时代”。移动互联网、人工智能等新技术带来的日新月异的改变,近年来,随着“互联网+”的快速普及,利用移动互联网、物联网、大数据、云计算技术推动信息化与行业深度融合,GPS三合一电子巡更管理系统集RFID读写、二维码、条形码、大数据处理、无线网络通信、图像处理等技术,有效的在智能化管理、安全防范、智能办公等方面充分发挥,运用云计算、大数据、物联网、可视化等技术,工作人员坐在办公室,只要轻点鼠标,通过WEB平台就能直观了解整个区域内巡检人员及区域内设施安全是否的实时情况。从而严格保障生产设备安全、稳定、高效运行而开展的针对诸多生产运营既定标准的常规检查规范性 一、系统背景 巡检是有效保证各项管理安全运行的一项基础工作。巡检的目的是为了能够及时、全面地掌握当前的运行状况及周围环境的变化,发现故障或缺陷以及有可能会危及到安全的一系列安全隐患,保证工作安全、稳定地运行。 为了监视设备和线路的正常运行,我们首先要做到及时发现。巡视人员必须要对巡逻地点进行定期或不定时巡视,并对当前的运行状况、运行参数进行记录存档,对任何危及安全的隐患做到及时发现,然后及时报告,提出具体的检修内容,并把内容实时发送到管理层电脑中。最后,由管理层安排相关人员进行及时的解决,确保工作的正常运行。

JDDJ电池巡检仪说明书V2.0

1.概述 JDDJ系列电池巡检仪,是我公司最新推出的用于蓄电池电压测量的直流电源柜配套产品。可以同爱默生网络能源有限公司(原深圳华为公司)以及同其他厂家制造的监控器联机通讯。 该产品经过用户的多年使用及跟踪调查,产品经过了几次从新的设计,目前产品的设计序号为第三代产品,系统的软硬件进行了重新设计,提高了产品运行的稳定性、可靠性,经过我们一年多的统计,新设计的电池巡检仪的返修率小于1%。目前我公司该产品主要有四个型号:JDDJ-1A,JDDJ-2C,JDDJ-3A,JDDJ-4A具体区别见型号说明。新的产品主要改进是产品运行的稳定性,抗干扰性。为用户提供一个放心使用的产品是我们的最终的目标。 2.功能与特点 2.1.在线跟踪监测电池组电压、充放电电流、电池表面温度; 2.2.采用160×80大屏幕液晶显示器,显示直观,数据量大; 2.3.平板嵌入式安装结构,不影响电池布置; 2.4. 带隔离的RS-485通讯接口,可实现数据的远传; 2.5 带有报警输出的继电器触点; 2.6 开放式协议,可与不同的监控装置联机通讯。 3. 型号说明 3.1 JDDJ-1A 最大可测量19路单只电池电压,电池组总电压,充放电电流,电池温度, 一组继电器报警触点,带有大屏幕液晶显示,该产品针对110V/220V系统12V电池的测量,具有RS485通讯接口。 3.2 JDDJ-2C 基本功能同JDDJ-1A,不带液晶显示,不测量电池组总电压,充放电电流, 没有报警触点。 JDDJ-2C巡检仪内有一个四位的红色拨码开关,具体定义如下: 3.2.1与艾默生公司监控通讯设置如下: 拨盘4是地址位,位于OFF地址为112,位于ON地址为113。 拨盘123为电池个数选择: 1 2 3 ON ON ON 对应 18只电池 OFF ON ON 对应19只电池 ON OFF ON 对应17只电池

相关文档
最新文档