Diffusion and mass transfer of boron in molten silicon during slag

Diffusion and mass transfer of boron in molten silicon during slag
Diffusion and mass transfer of boron in molten silicon during slag

Diffusion and mass transfer of boron in molten silicon during slag re ?ning process of metallurgical grade silicon

Jijun Wu a ,b ,*,Fanmao Wang b ,Zhengjie Chen b ,Wenhui Ma a ,b ,*,Yanlong Li b ,Bin Yang a ,Yongnian Dai a ,b

a

State Key Laboratory of Complex Nonferrous Metal Resources Cleaning Utilization in Yunnan Province/The National Engineering Laboratory for Vacuum Metallurgy,Kunming University of Science and Technology,Kunming 650093,China b

Engineering Research Center for Silicon Metallurgy and Silicon Materials of Yunnan Provincial Universities/Faculty of Metallurgical and Energy Engineering,Kunming University of Science and Technology,Kunming 650093,China

A R T I C L E I N F O

Article history:

Received 10April 2015

Received in revised form 24June 2015Accepted 25June 2015

Available online 2July 2015

Keywords:

Solar-grade polysilicon Boron removal Kinetics

Diffusion coef ?cient

Mass transfer coef ?cient Boundary layer

A B S T R A C T

In this paper,the formulas of diffusion coef ?cient (D )and mass transfer coef ?cient (b )of boron in molten silicon were deduced.The diffusion coef ?cient of boron was determined to be 1.46?10à8m 2s à1by the diffusion experiment at 1823K in the resistance furnace.The mass transfer process of boron between silicon and slag was described using the two-?lm theory and the mass transfer coef ?cient (b )of boron was measured to be 1.7?10à4m s à1while using the binary CaO –SiO 2slag re ?ning at 1823K.It was calculated by the relation between diffusion coef ?cient and mass transfer coef ?cient that the effective boundary layer thickness (d )close to molten silicon side was 0.086mm.

?2015Elsevier B.V.All rights reserved.

1.Introduction

The solar-grade polysilicon used as solar cell materials is mainly produced by the chemical methods including the Siemens process and the Fluidized Bed Reactor [1–3].As a result of some disadvantages such as high cost and heavy environmental pollution,the chemical route is being substituted by some other techniques [4,5].The metallurgical route for a low cost solar-grade polysilicon production has gradually become a hot topic of research.In this route,the slag re ?ning can effectively remove impurity boron from metallurgical grade silicon and most of current researches have focused on the thermodynamics of boron removal by this method [6–9].Wu et al.[10]found that boron in metallurgical grade silicon could be removed from 18ppmw to 1.4ppmw using a re ?ning technique of high basic slag.Also,the thermodynamic relation between distribution coef ?cient of boron (L B )and slag activity parameter was established and con ?rmed.Li et al.[11]described that boron can be removed by increasing the

basicity and the oxygen potential of slag.Fang et al.[12]found that the boron concentration in silicon can be decreased from 10.6ppmw to 0.65ppmw by Na 2O –SiO 2slag re ?ning treatment and it is bene ?cial for boron removal while increasing re ?ning time under the condition of a small mass ratio of slag to silicon.

Some studies [13,14]show that the kinetic factors such as the diffusions of boron in molten silicon and borate in slag play the important roles to boron removal during the process of slag re ?ning.The diffusion coef ?cient of boron in silicon melt was calculated to be 2.7?10à4cm 2s à1by Tang et al.[15]and it was also experimentally determined to be (2.4?0.7)?10à4cm 2s à1by Kodera [16].Based on the work of Kodera [16],Garandet [17]propose new determinations of the diffusion coef ?cients of various dopants in liquid silicon,and a diffusion coef ?cient of 1.2?10à8m 2s à1for boron in silicon melt was gotten.It has been reported that the rate controlling step of boron removal from metallurgical grade silicon is the mass transfer process of borate in slag.Nishimoto et al.[18]found that the boron removal rate was controlled by mass transport in the calcium silicate slag with a mass-transfer coef ?cient (k S )of 1.4?10à6m/s.Krystad et al.[19]had also reported the larger values for the same slag and temperature in the range of 1.7?10à6–3.5?10à6m/s and a relatively larger value of 4.3?10à6m/s has also been obtained using the CaO –MgO –SiO 2slag.Zhang et al.[20]calculated the total mass transfer coef ?cient of boron to be 6.85?10à4cm/s for the 10%CaF 2–10%Al 2O 3–20%CaO –60%SiO 2slag at 2073K.

*Corresponding authors at:State Key Laboratory of Complex Nonferrous Metal Resources Cleaning Utilization in Yunnan Province/The National Engineering Laboratory for Vacuum Metallurgy,Kunming University of Science and Technology,Kunming 650093,China.Fax:+8687165161583.

E-mail addresses:dragon_wu213@https://www.360docs.net/doc/431520039.html, (J.Wu),mwhsilicon@https://www.360docs.net/doc/431520039.html, (W.Ma).

https://www.360docs.net/doc/431520039.html,/10.1016/j.?uid.2015.06.040

0378-3812/?2015Elsevier B.V.All rights reserved.

Fluid Phase Equilibria 404(2015)70–74

Contents lists available at ScienceDirect

Fluid Phase Equilibria

j o u r n a l h o m e p a g e :w w w.e l s e v i e r.c o m /l o c a t e /?u i

d

In this paper,the diffusion coef ?cient of boron in molten silicon was determined by experiments.The mass transfer coef ?cient of boron removal using the binary CaO –SiO 2slag re ?ning was also measured and calculated.The functional relationship between boron concentration in silicon and re ?ning time was established and con ?rmed.Simultaneously,the effective boundary layer thickness close to silicon side was derived from the relationship between mass transfer coef ?cient and diffusion coef ?cient of boron.

2.Theoretical formulations

The boron atoms will diffuse from solid boron toward liquid silicon when the solid boron and the liquid silicon are placed together.The concentration gradient of boron in molten silicon will be formed and distributed from the solid –liquid interface of B –Si with a high boron concentration to the molten silicon with a low boron concentration.Finally,the boron concentration in whole liquid silicon will be saturated.The schematic diagram of boron diffusion from B –Si interface to liquid silicon is shown in Fig.1.According to Fick ’s second law,the diffusion rate of boron in molten silicon can be described as Eq.(1).

@c @t ?D @2c @x !

(1)The initial and boundary conditions of differential Eq.(1)are shown in Eqs.(2)and (3).

c ex ;0T

?g S

d ex T(2)

@c e0;t T

@x

?0(3)

where g and S are the total quantity and the sectional area of diffusible substance,respectively.d ex Tis the Dirac function at x 0?0.The property of Dirac function d ex Tcan be expressed as Eqs.(4)and (5).

d ex àx 0T?0;x ?x 0t1;x ?x 0

(4)

Z

t1à1

d ex àx 0Td x ?1

(5)

Then,the integral result of Eq.(1)at the initial and boundary conditions for Eqs.(2)and (3)is shown in Eq.(6).

c ex ;t T?g S ??????????p D t

p exp à

x 2

4D t

(6)

In the form of logarithm for Eqs.(6)and (7)can be gotten.

lg c ex ;t T?lg g S ??????????p D t p à

x 2

2:3e4D t T

(7)

By drawing to data,the curve of lg c ex ;t Tàx 2and its slope (k )can be gotten and represented as Eq.(8).

k ?

19:2D t

(8)

And lastly,the diffusion coef ?cient of boron in molten silicon (D )can be calculated and gotten according to Eq.(8).

During the slag re ?ning process of boron removal,there must be a silicon boundary layer (d )and a slag boundary layer (d 0),respectively.According to the two-?lm theory,the oxidation and removal process of boron in silicon by the binary CaO –SiO 2slag re ?ning can be shown in Fig.2.

According to the boundary-layer theory of convective mass transfer,the convective mass transfer rate is zero (u xc =0)at the verticality of phase interface,where the characteristics of mass transfer is an unsteady state diffusion.So the mass transfer rate of boron can be explained as Eq.(9):

J ?àD

@c @ x ?0?V ?d c

(9)Meanwhile,it can also be described as Eq.(10)

J ?b c àc ?eT

(10)

Then,Eq.(11)can be obtained by Eq.(9)=Eq.(10).d c d t ?àb ?A

V

?ec àc ?T(11)

where b is the mass transfer coef ?cient of boron in molten silicon.A and V are the interface area of between silicon and slag and the volume of molten silicon,respectively.c and c *are the boron concentrations in the molten silicon and at the interface of silicon-slag,respectively.

The interface concentration (c *)can be replaced by the equilibrium concentration of boron in silicon (c e )for a very fast reaction rate of boron oxidation at the interface of silicon-slag.After substituting the molar concentration (c )with the weight percent concentration (w [B]),Eq.(12)can be obtained by integrating Eq.(11).The value of mass transfer coef ?cient (b )can be described as the slope of curve.

ln

w ?B àw ?B e w ?B 0àw ?B e

?àb ?r m A

M m ?t (12)

where w [B]is the mass concentration of boron in silicon after the

re ?ning time (t ).w [B]0and w [B]e are the initial and the equilibrium mass concentrations of boron in molten silicon,respectively.r m and M m are the density and the mass of molten silicon,

respectively.

Fig.1.Schematic diagram of boron diffusion in molten

silicon.

Fig.2.Schematic diagram of boron oxidation and removal by CaO –SiO 2slag.

J.Wu et al./Fluid Phase Equilibria 404(2015)70–74

71

3.Experimental

The boron powder of 5g with a purity of 4N was ?rstly pressed into a slice with a diameter of 20mm and a thickness of 5mm.The electronic grade silicon powder of 50g with a purity of 9N was put into a high purity graphite crucible (F 40mm ?60mm)and the upper surface of silicon powder was smoothed.Then the boron slice was placed on the surface of silicon powder.Subsequently,the graphite crucible was put into a resistance furnace and carried out for the diffusion experiment under the protection of argon gas.After it was kept at 1873K for 180min,the sample was cooled to room temperature and removed out from furnace.Finally,the sample was lengthways cut into half and the boron concentrations of different sampling positions at a distance of every 3mm away from the B –Si interface were analyzed by the Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES).The schematic diagram of diffusion experiment and the appearance picture of sampling are shown in Fig.3.

The raw material of re ?ning experiment for boron removal was the metallurgical grade silicon with a boron concentration of 22ppmw.The slag re ?ning agent was composed of 50%CaO –50%SiO 2.Firstly,the metallurgical grade silicon of 20g and the calcium silicate slag of 20g were loaded into a high purity graphite crucible with an inner diameter of 40mm and a height of 60mm.The slag was laid the upside of silicon.Then,the crucible was put into the heating zone of resistance furnace for re ?ning at 1823K with

different holding times of 30–180min,respectively,under the protection of argon gas.The experimental sample is shown in Fig.4.It can be seen that the Si –B interface obviously exist between molten silicon and molten https://www.360docs.net/doc/431520039.html,stly,the boron concentration in re ?ned silicon was analyzed by the Inductively Coupled Plasma Mass Spectrometry (ICP-MS).

4.Results and discussion

The B –Si interface between solid boron and molten silicon is considered as the initial position (“0”mm).The boron concen-trations with 3mm,6mm,9mm,12mm and 15mm,respectively,away from the B –Si interface as shown in Fig.3(b)are analyzed and the results were shown in Fig.5.It is found that the boron concentration of sampling point gradually reduces with the increase of diffusion distance away from the B –Si interface.A non-linear decreasing trend displays that the boron diffusion in molten silicon is an unsteady state diffusion process,which con ?rms the deduced result ahead.

According to the binary Si –B phase diagram,the maximal concentration of boron in liquid phase (on the liquidus)reaches 7.4%at 1823K.On account of the use of a solid boron powder slice in the diffusion experiment,it is consequently considered that the dissolution of boron in molten silicon has reached a saturated state at the B –Si interface and the boron concentration at the B –Si interface can be replaced by the saturated solubility.Therefore,

the

Fig.3.Schematic diagram of diffusion experiment (a)and appearance picture of sampling

(b).

Fig.4.Schematic (a)and appearance (b)diagrams of slag re ?ning using the binary CaO –SiO 2slag.

72

J.Wu et al./Fluid Phase Equilibria 404(2015)70–74

linear ?tting results for the diffusion coef ?cient of boron in molten silicon (D )at 1823K are obtained and shown in Fig.6according to ?ve sampling points by Eqs.(7)and (8).It is gotten as D =1.46?10à8m 2s à1and shown in Table 1.

Due to the large diameter/height size of crucible and the experimental factor such as convection,the result is a little lower than the value of 2.7?10à4cm 2s à1estimated by Tang et al.[15]using the Arrhenius equation but higher than the value of 1.2?10à8m 2s à1posed d by Garandet [17].The boron concentra-tion in re ?ned silicon using the binary CaO –SiO 2slag re ?ning with different time of 30–180min shown in Table 1.In the process of boron removal by slag re ?ning,the mass conservation of boron between molten silicon and molten slag can be shown in Eq.(13).

M m B w ?B 0?M m B w ?B e tM s

BO 1:5

w eBO 1:5Te (13)

The mass distribution coef ?cient (L B )of boron between slag and silicon in equilibrium is represented in Eq.(14).

L B ?

w eBO 1:5Te w ?B e

(14)

Lastly,the boron concentration can be described as Eq.(15)when it reaches equilibrium.

w ?B e ?

w ?B 0?M BO 1:5=M B

L B ?M s =M m tM BO 1:5=M B

(15)

where L B is the mass distribution coef ?cient of boron between slag and silicon in equilibrium.M s and M m are the mass of molten slag and molten silicon,respectively.M BO 1:5and M B are the molar mass of boron oxide and boron,respectively.

It is calculated that the equilibrium boron concentration in molten silicon (w ?B e )is about 2.6ppmw with a L B value of 1.8by Eq.(15).Then,the equilibrium boron concentration is substituted into Eq.(14)and the relationship between re ?ning time (t )and Y ln X is obtained and shown in Eq.(16).X and Y are represented by Eqs.(17)and (18).

Y ln X ?àb ?t

(16)

X ?

w ?B àw ?B e w ?B 0àw ?B e

(17)

Y ?

M m r m A

(18)

Lastly,the curve derived by Eq.(16)is gotten in experiment and drawn in Fig.7.Obviously,the slope of straight line is just the mass transfer coef ?cient (b )of boron in molten silicon and it is calculated to be 1.7?10à4m s à1.

It exists a difference of ?uidity between the immiscible molten silicon and molten slag at 1823K.Therefore,a boundary layer between molten silicon and molten slag is generated.It is de ?ned that the distance of intersection point between the tangent of boron concentration distribution curve at x =0and the extension line of concentration curve (c )away from silicon-slag interface is the effective boundary layer close to silicon side.The schematic diagram of boundary layer is described in Fig.8.d can be calculated by Eq.(19).

d ?

c àc ?@c =@x eTx ?0

(19)

where @c =@x eTx ?0is the concentration gradient of boron nearby the interface of molten silicon and molten slag.c *is the boron concentration at the silicon-slag interface.In the meantime,Eq.(20)can be obtained by Eqs.(9)and (11),which displays the relationship between D and b .

D ?b ?d

(20)

Finally,the effective boundary layer thickness (d )can be calculate.

As it has been found by Nishimoto et al.[18]that the

mass

Fig.5.Boron concentration of sampling point in silicon with different distance away from B –Si

interface.

Fig.6.Linear ?tting results by experimental data.

Table 1

Experimental results of diffusion coef ?cient (D )and mass transfer coef ?cient (b ).

Sampling points

x i /mm w [B]/%D ?10à8/m 2s à1

Re ?ning time/min

w [B]/ppmw b ?10à4/m s à1

1#30.75222#60.723014.83#90.68 1.46

609.5 1.7

4#120.62120 4.75#

15

0.53

180

3.7

J.Wu et al./Fluid Phase Equilibria 404(2015)70–74

73

transport in the slag phase is the rate-controlling step,and hence the boundary layer thickness is 0.086mm when this is the case.

5.Conclusions

The diffusion coef ?cient (D )of boron in molten silicon at 1823K was determined,D =1.46?10à8m 2s à1,by the diffusion experi-ment in the resistance furnace and the mass transfer coef ?cient (b )of boron was also measured and calculated b =1.7?10à4m s à1using the binary CaO –SiO 2slag re ?ning.It was calculated by the relation between diffusion coef ?cient and mass transfer coef ?cient

that the effective boundary layer thickness (d )close to molten silicon side was d =0.086mm.

Acknowledgements

The authors wish to acknowledge the ?nancial support on this research from National Natural Science Foundation of China (51104080and 51334002)and the Natural Science Foundation of Yunnan Province (2014FB124).

References

[1]W.O.Filtvedt,A.Holt,P.A.Ramachandran,M.C.Melaaen,Chemical vapor

deposition of silicon from silane:review of growth mechanisms and modeling/scaleup of ?uidized bed reactors,Solar Energy Mater.Solar Cells 107(2012)188–200.

[2]S.Richter,M.Werner,M.Schley,F.Schaaff,H.Riemann,H.J.Rost,F.Zobel,R.

Kunert,P.Dold, C.Hagendorf,Structural and chemical investigations of adapted Siemens feed rods for an optimized ?oat zone process,Energy Procedia 38(2013)604–610.

[3]H.Ni,S.Lu,C.Chen,Modeling and simulation of silicon epitaxial growth in

Siemens CVD reactor,J.Cryst.Growth 404(2014)89–99.

[4]H.A.Aulich,F.W.Schulze,Crystalline silicon feedstock for solar cell,Prog.

Photovoltaics:Res.Appl.10(2002)141–147.

[5]L.Cai,X.Ren,B.Fan,J.Zheng,C.Chen,Effect of temperature on crystalline

silicon solar cells processed from chemical and metallurgical route,Optik 125(2014)3918–3921.

[6]Y.Li,J.Wu,W.Ma,Kinetics of boron removal from metallurgical grade silicon

using a slag re ?ning technique based on CaO –SiO 2binary system,Sep.Sci.Technol.49(2014)1946–1952.

[7]J.Wu,Y.Li,W.Ma,K.Wei, B.Yang,Y.Dai,Boron removal in purifying

metallurgical grade silicon by a CaO –SiO 2slag re ?ning,Trans.Nonferrous Met.Soc.China 24(2014)1231–1236.

[8]K.Morita,T.Miki,Thermodynamics of solar-grade-silicon re ?ning,

Intermetallics 11(2003)1111–1117.

[9]L.A.V.Teixeira,K.Morita,Removal of boron from molten silicon using CaO –

SiO 2based slags,ISIJ Int.49(2009)783–787.

[10]J.Wu,M.Xu,K.Liu,W.Ma,B.Yang,Y.Dai,Removing boron from metallurgical

grade silicon by a high basic slag re ?ning technique,J.Min.Metall.B 50(2014)83–86.

[11]M.Li,T.Utigard,M.Barati,Removal of boron and phosphorus from silicon

using CaO –SiO 2–Na 2O –Al 2O 3?ux,Metall.Mater.Trans.B 45(2014)221–228.[12]M.Fang,C.Lu,L.Huang,https://www.360docs.net/doc/431520039.html,i,J.Chen,X.Yang,J.Li,W.Ma,P.Xing,X.Luo,

Multiple Slag operation on boron removal from metallurgical-grade silicon using Na 2O –SiO 2Slags,Ind.Eng.Chem.Res.53(2014)12054–12062.

[13]J.Safarian,G.Tranell,M.Tangstad,Thermodynamic and kinetic behavior of B

and Na through the contact of B-doped silicon with Na 2O –SiO 2slags,Metall.Mater.Trans.B 44(2013)571–583.

[14]J.F.White,D.Sichen,Mass transfer in slag re ?ning of silicon with mechanical

stirring:transient kinetics of Ca and B transfer,Metall.Mater.Trans.B 46(2015)135–144.

[15]K.Tang,E.J.?vrelid,G.Tranell,M.Tangstad,Critical assessment of the impurity

diffusivities in solid and liquid silicon,JOM 61(2009)49–55.

[16]H.Kodera,Diffusion coef ?cients of impurities in silicon melt,Jpn.J.Appl.Phys.

2(1963)212–219.

[17]J.P.Garandet,New determinations of diffusion coef ?cients for various dopants

in liquid silicon,Int.J.Thermophys.28(2007)1285–1305.

[18]H.Nishimoto,Y.Kang,T.Yoshikawa,K.Morita,The rate of boron removal from

molten silicon by CaO –SiO 2slag and Cl2treatment,High Temp.Mater.Processes 31(2012)471–477.

[19]E.Krystad,S.Zhang,G.Tranell,The kinetics of boron removal during slag

re ?ning in the production of solar-grade silicon,in:L.F.Zhang,J.A.Pomykala,A.Ciftja (Eds.),EPD Congress 2012(TMS),FL,USA,2012,pp.471–480.

[20]L.Zhang,Y.Tan,J.Y.Li,Y.Liu,D.K.Wang,J.Y.Li,Study of boron removal from

molten silicon by slag re ?ning under atmosphere,Mater.Sci.Semicond.Process.16(2013)1645–1649

.

Fig.7.Relationship between Y ln X and re ?ning time (t

).

Fig.8.Schematic diagram of boundary layer close to silicon side.

74

J.Wu et al./Fluid Phase Equilibria 404(2015)70–74

安捷伦高效液相色谱仪的规范操作

安捷伦高效液相色谱仪的规范操作 1. 目的:明确安捷伦高效液相色谱仪的规范操作,确保数据的准确性。 2. 范围:适用于安捷伦高效液相色谱仪。 3. 职责:检验人员对此负责。 4.操作规程: 系统组成 本系统由1个溶剂二元输送泵(分主/A泵和副/B泵)、手动进样阀、柱温箱、检测器、化学工作站和电脑等组成。 准备 4.2.1使用前应根据待检样品的检验方法准备所需的流动相,用合适的μm滤膜过滤,超声脱气20min。 4.2.2 根据待检样品的需要更换合适的色谱柱(柱进出口位置应与流动相流向一致)和定量环。 4.2.3 配制样品和标准溶液(也可在平衡系统时配制),用合适的μm滤膜过滤。 4.2.4 检查仪器各部件的电源线、数据线和输液管道是否连接正常 将待测样品按要求前处理,准备HPLC 所需流动相,检查线路是否连接完好,废液瓶是否够用等。 开机: 4.3.1 打开计算机,进入中文Windows XP画面,并运行CAG Bootp Server程序。4.3.2 打开1200 LC 各模块电源。 4.3.3 待各模块自检完成后,双击[Instrument 1 Online]图标,化学工作站自动与1200LC 通讯,进入的工作站画面如下所示。 4.3.4 从[视图]菜单中选择[方法和运行控制]画面, 点击[视图]菜单中的[显示顶部工具栏],[ 显示状态工具栏],[系统视图],[样品视图],使其命令前有[√]标志,来调用所需的界面。 4.3.5 把流动相放入溶剂瓶中。

4.3.6 打开冲洗阀。 4.3.7 点击[泵]图标,点击[设置泵…]选项,进入泵编辑画面。 4.3.8 设流速:5ml/min,点击[确定]。 4.3.9 点击[泵] 图标,点击[控制…]选项,选中[启动],点击[确定] ,则系统开始冲洗,直到管线内(由溶剂瓶到泵入口)无气泡为止,切换通道继续冲洗,直到所有要用通道无气泡为止。 4.3.10 点击[泵] 图标,点击[控制…]选项,选中[关闭],点击[确定]关泵,关闭冲洗阀。 4.3.11 点击[泵]图标,点击[设置泵…选项],设流速:min。 4.3.12 点击泵下面的瓶图标,如下图所示(以单元泵为例),输入溶剂的实际体积和瓶体积。也可输入停泵的体积,点击[确定]。 数据采集方法编辑 4.4.1开始编辑完整方法:从[方法]菜单中选择[编辑完整方法…] 项,如下图所示选中除[数据分析]外的三项,点击[确定],进入下一画面。 4.4.2方法信息 4.4.2.1在[方法注释]中加入方法的信息(如:测试方法)。 4.4.2.2 点击[确定],进入下一画面。 4.4.3 泵参数设定 4.4.3.1 在[流速]处输入流量,如1ml/min,在[溶剂B]处输入,(A=100-B) ,也可[插入]一行[时间表] ,编辑梯度。在[压力限]处输入柱子的最大耐高压,以保护柱子。 4.4.3.2 点击[确定],进入下一画面。 4.4.4 柱温箱参数设定 4.4.4.1 在[温度]下面的空白方框内输入所需温度,如:40度。并选中它,点击[更多>>] 键,如图所示,选中[与左侧相同],使柱温箱的温度左右一致。 4.4.4.2 点击[确定],进入下一画面。 4.4.5 检测器参数设定:检测波长:一般选择最大吸收处的波长。样品带宽:一般选择最大吸收值一半处的整个宽度。参比波长:一般选择在靠近样品信号的无吸收或低吸收区 域。参比带宽:至少要与样品信号的带宽相等,许多情况下用100nm作为缺省

Agilent-1290-超高效液相色谱仪标准操作规程

Agilent 1290 超高效液相色谱仪标准操作规程 一、目的 制定Agilent 1290超高效液相色谱仪使用操作规程,确保操作人员能正确规范地操作液相色谱仪。 二、范围 适用于Agilent1290超高效液相色谱仪的使用。 三、操作规程 1 开机 1.1 打开计算机,进入 Windows画面。 1.2 打开 1290INFINITY HPLC 各模块电源。 1.3 待各模块自检完成后,双击“Instrument 1 Online”图标,化学工作站自动与 12001290INFINITY HPLC 通讯。 1.4 从“View”菜单中选择“方法和运行控制”画面,点击”视图”菜单中的“样品视图 “系统视图”,使其命令前有“√”标志,来调用所需的界面。 1.5 点击泵下面的瓶图标,选择‘瓶填充‘如下图所示,输入溶剂的实际体积和瓶体积。也 可输入停泵的体积。点击“Ok”。 1.6 从菜单“视图”中,选中“在线信号”,选中“信号窗口 1”,然后点击“改变…”钮, 将所要绘图的信号移到右边的框中,点击“确定”。(如同时检测二个信号,则重复选中“信号窗口 2”) 2 排气 2.1 首先在方法编辑中,泵的参数设置部分,选好需要排空的通道(保证是开的) 2.2 点击仪器状态视图中泵的图标,选择控制,出现如下图 2.3 勾上吹扫,并且输入流速,时间,比例就可以 purge 泵头。排空的时候阀会自动切换, 无需人为介入。 2.4 当我们发现泵头里面有气泡出不来的时候,选择预备---开。然后点击确定。此时泵会 用很强烈的方式朝外泵液体,并持续 20 次自动停止。 3 编辑数据采集方法 3.1 开始编辑完整方法: 从“方法”菜单中选择“编辑完整方法…”项,如下图所示选中除“数据分析”外

安捷伦1260高效液相色谱仪操作规程资料

安捷伦1260高效液相色谱仪操作规程

安捷伦1260高效液相色谱仪操作规程一、开机 (1)打开计算机,登陆windows操作系统。 (2)打开主机各模块电源(从上至下),待各模块完成自检后,再双击桌面“仪器1联机”图标,进入化学工作站,从视图菜单中选择“方法和运行控制”画面。 (3)进行仪器配置,点仪器-仪器配置-选择所需模块-自动配置-输入IP地址:192.168.254.11。把各流动相放入相应的溶剂瓶中。 (4)编辑方法。方法-新建方法-方法-编辑完整方法-编辑各项(四元泵、TCC、VWD、仪器曲线参数设定,仪器参数默认),完成后,文件→方法另存为→编辑名称,保存方法。 (5)排气。旋开排气阀(逆时针),右单击“四元泵”图标出现快捷键,点击“方法”设置泵流速,排气可设置1.2ml/min,l流量梯度100,也可 5ml/min,流量梯度10。一般冲洗3-5min,注意倾斜储液瓶使过滤头处 的气体进入管道才可使气体排出,观察管路中气体位置,以其排净为目的。关泵,关闭排气阀(顺时针)。(注意:先开排气阀,再开泵,先关泵,后关排气阀)。 (6)在让液体进入柱子之前应将甁填充设置为实际值,谨防空进。将泵流速设置1ml/min,用过渡液即缓冲液冲洗色谱柱20—30分钟。 (7)换流动相,待柱前压力基本稳定后,打开检测器,视图,在线信号,选择信号,观察基线情况。 二、数据采集信息编辑及进样

(1)编辑样品信息:点“单次样品”小瓶,或点击运行信息-单次进样,设定操作者姓名,样品数据文件名,进样量等。 (2)编辑好样品信息后方可进样。 三、数据处理 (1)打开桌面“仪器1脱机”,单击“数据分析”进入数据分析画面。 (2)从“文件”菜单中选择调用信号,选择您的数据文件名,单击确定。(3)谱图优化。从“图形”菜单中选择“信号选项”从范围中选择“自动量程”及合适的显示时间,或选择“自定义量程”调整,反复进行,直到图比例合适 为止。 (4)积分。从“积分”中选择“自动积分”,若积分结果不理想,从菜单中选“积分事件”,更改数据为合适的“斜率灵敏度、峰宽、最小峰面积、最小峰 高”,从“积分”中选择积分选项,则数据被积分,如积分结果不理想则修改相应的积分参数直到满意为止。单击左边图标将积分参数存入方法。(5)校正表设计。点击“校正”菜单中的“校正设置”给出各个参数,点击确定,调出建立校正表所需的谱图并对谱图进行图形优化和积分优化。点击校正→新建校正表,选择自动设定→确定,在校正表中给出正确的“化合物名”和“含量”如需增加校正点数,校正→添加级别,给出第二校正点的含量,以此类推。校正表建立完成后点击“确定”点击“保存图标”将校正表存入方法中,或点击文件-方法另存为-找到对应文件夹,编辑日期及前缀 存入。

高效液相色谱仪(Agilent 1100型)操作步骤

一、开机 1、开机前准备:流动相使用前必须过0.45um的滤膜(有机相的流动相必须为色谱纯;水相必须用新鲜注射用水,不能使用超过3天的注射用水,以防止长菌或长藻类);把流动相放入溶剂瓶中。A瓶:为水相;B瓶:为有机相。 2、打开电脑,选Win 2000,进入Win 2000界面。 3、双击CAG Boodp server图标,放大CAG Boodp server小图标,出现窗口,5min内打开液相各部件电源开关,等待1100广播信息后,表示通讯成功连接,关闭CAG Boodp serve窗口。 4、双击online图标,仪器自检,进入工作站。 该页面主要由以下几部分组成: ——最上方为命令栏,依次为File,Run Control,Instrumen…等; ——命令栏下方为快捷操作图标,如多个样品连续进行分析、单个样品进样分析、调用文件保存文件……等; ——中部为工作站各部件的工作流程示意图;依次为进样器-输液泵-柱温箱-检测器-数据处理-报告; ——中下部为动态监测信号; ——右下部为色谱工作参数:进样体积、流速、分析停止时间、流动相比例、柱温、检测波长等。 4、从“View”菜单中选择“Method and control”画面。 二、编辑参数及方法 1、开始编辑完整方法: 从“Method”菜单中选择“New method”,出现DEF-LC.M,从“Method”菜单中选择“Edit entire method”,选择方法信息、仪器参数及收集参数、数据分析参数和运行时间表等各项,单击OK,进入下一画面。 2、方法信息: 在“Method Comments”中加入方法的信息,如方法的用途等。单击OK,进入下一画面。 3、泵参数设定: 进入“Setup pump”画面,在“Flow” 处输入流量,如1ml/min;在“Solvent B”处输入有机相的比例如70.0,(A=100-B),也可在Insert 一行“Timetable”,编辑梯度;输入保留时间;在“Pressure Limits Max”处输入柱子的最大耐高压,以保护柱子。单击OK,进入下一画面。 4、DAD检测器参数设定: 进入“DAD signals”画面,输入样品波长及其带宽、参比波长及其带宽(参比波长带宽默认值为100nm);选择Stoptime:as Pupm; 在“Spectrum”中输入采集光谱方式“store”:选All;如只进行正常检测,则可选None;范围Range:可选范围为190~950nm;步长Step可选2.0nm;阀值:选择需要的灯; Peak width(Response time)即响应值应尽可能接近要测的窄峰峰宽,可选“2s”或4s; Slit-:狭窄缝,光谱分辨率高;宽时,噪音低。可选4nm

(完整版)Agilent1260液相色谱系统操作规程

1目的 规范Agile nt 1260系列高效液相色谱的日常使用和维护保养,保证仪器的正常运转,确保检测工作的顺利进行。 2适用范围 适用于Agile nt 1260系列高效液相色谱系统的日常使用和维护。 3职责 实验室分析人员负责Agile nt 1260系列高效液相色谱系统的日常使用和维护。 4系统组成 4.1 Agile nt 1260 系列四元泵(G1311C)和脱气机; 4.2可变波长紫外检测器(VWD G1314F ; 4.3 Chemstation A.01.04 色谱工作站 4.4国产柱温箱(AT-550)色谱柱; 4.5电脑、打印机等辅助设备。 5定义 无 6操作程序 6.1开机前的准备 6.1.1检查仪器校验标识,确认仪器处于校验周期内。 6.1.2检查上次《实验室仪器设备使用记录表》和仪器状态,确认仪器处于正常状态; 6.1.3流动相的制备: 6.1.3.1按《高效液相色谱法流动相配制标准操作规程》配制需要的流动相。 6.1.3.2用前超声脱气(一般10?20min)。 6.1.4更换流动相: 6.1.4.1将泵的吸滤器从旧流动相中取出,用新流动相冲洗后放入新流动相的储液瓶中,并盖好瓶盖; 6.1.4.2将排液管的出口端放入废液瓶中,并盖好瓶盖。 6.1.5供试溶液的配制:

6.1.5.1供试品用规定溶剂配制成供试品溶液。 6.1.5.2定量测定时,对照品溶液和供试品溶液均应分别配制 2份。 6.1.5.2如有必要,样品需预处理,如过滤等,以免对色谱系统产生污染和色谱干扰。 6.1.6选择色谱柱: 6.1.6.1根据待检供试品的检测方法确定所需的色谱柱; 6.1.6.2检查仪器上安装的色谱柱是否与其相同,若不同则需进行更换。 6.1.7更换色谱柱 6.1. 7.1拆卸原色谱柱: 先握住色谱柱,再松动色谱柱出口端螺帽,取下出口端的管线; 松动色谱柱入口端螺帽,取下入口端的管线; 用止动塞将色谱柱的进出口塞住拧紧后,将色谱柱放回原专用包装盒内 6.1. 7.2安装新色谱柱: 从专用包装盒内取出色谱柱,松动并取下色谱柱出入口的止动塞; 将与进样器相连的管线一端插入色谱柱入口端,拧紧螺帽; (注意:安装时色谱柱上的流向标志应与管路的流动相流向一致。 ) 将与检测器相连的管线一端插入色谱柱出口端,拧紧螺帽。 6.2开机 6.2.1通电前应检查仪器设备之间的电源线、数据线和输液管道是否连接正常。 6.2.2接通电源,打开计算机和打印机开关 6.2.3等待计算机自检完毕后,进入 Windows 桌面,依次打开泵、进样器、检测器各模块电源。 打开柱温箱开关。 6.2.4待各模块自检完成后,点击 6.2.5确定仪器与工作站已连接,若未连接,需关闭工作站,重新连接。注意必须先打开检测器, 再连接 工作站。 6.2.6从“视图”菜单中选择“方法和运行控制”画面 ,也可单击工作站画面左侧的“方法和运行 控制”项,进入方法和运行控制窗口。 6.3 操作 6.3.1泵的开启和设置 6.3.1.1打开Purge 阀(逆时针),右键点击四元泵下面的空白处,选择“方法”选项,进入泵 编辑画面。 Win dows 桌面 lc ”图标进入化学工作站画面

安捷伦液相使用方法

高效液相色谱仪的使用方法2008-05-11 20:24仪器名称:高效液相色谱仪 仪器型号:Agilent 1100 生产厂家:Agilent 使用方法: (一)、开机: 1、打开计算机,进入Windows NT (或Windows 2000)画面,并运行Bootp Server程序。 2、打开1100 LC 各模块电源。 3、待各模块自检完成后,双击Instrument 1 Online图标,化学工作站自动与1100LC通讯,进入的工作站画面如下所示。 4、从“View”菜单中选择“Method and Run control”画面, 单击”View”菜单中的“Show Top Toolbar”,“Show status toolbar”,“System diagram”,”Sampling diagram”,使其命令前有“√”标志,来调用所需的界面。 5、把流动相放入溶剂瓶中。 6、打开Purge阀。 7、单击Pump图标,出现参数设定菜单,单击Setup pump选项,进入泵编辑画面。 8 、设Flow:5ml/min,单击OK。 9、单击Pump图标,出现参数设定菜单,单击Pump control选项,选中On,单击OK,则系统开始Purge,直到管线内(由溶剂瓶到泵入口)无气泡为止,切换通道继续Purge,直到所有要用通道无气泡为止。 10、单击Pump图标,出现参数设定菜单,单击Pump Control选项,选中Off,单击Ok关泵,关闭 Purge valve。 11、单击Pump图标,出现参数设定菜单,单击Setup pump选项,进入Pump编辑画面,设Flow:1.0ml/min。 12、单击泵下面的瓶图标,如图所示(以二元泵为例),输入溶剂的实际体积和瓶体积。也可输入停泵的体积。单击Ok。 (二)数据采集方法编辑: 1、开始编辑完整方法: 从“Method”菜单中选择“Edit entire method”项,如上图所示选中除“Data analysis ”外的三项,单击Ok,进入下一画面。 2、方法信息: 在“Method Comments”中加入方法的信息(如:方法的用途等)。 单击Ok 进入下一画面。 3、泵参数设定:(以二元泵为例) 在“Flow”处输入流量,如1ml/min,在“Solvent B”处输入70.0,(A=100-B) ,也可Insert 一行”Timetable”,编辑梯度。在“Pressure Limits Max”处输入柱子的最大耐高压,以保护柱子。单击Ok进入下一画面。 4、自动进样器参数设定: 选择合适的进样方式, 如图所示,进样体积1.0ul ,洗瓶位置为6号。“Standard Injection”----只能输入进样体积,此方式无洗针功能。“Injection with Needle Wash”----可以输入进样体积和洗瓶位置,此方式针从样品瓶抽完样品后,会在洗瓶中洗针。“Use injector program”---可以点击Edit 键进行进样程序编辑。

agilent高效液相色谱仪标准操作程序

Agilent 1200高效液相色谱仪标准操作程序 1.目的 使操作人员的操作步骤规范化. 2.适用范围 适用于仪器安装、调试、校准后正常状态下进行的操作. 3.责任者 质控科仪器分析员对此规程负责. 4.规程 4.1清洗液、流动相、封柱液预处理 4.1.1所有清洗液、流动相、封柱液在使用前均需过滤、脱气以及混合均匀. 4.1.2甲醇-水(10:90)、乙腈-水(10:90)、超净水、乙腈均需存放在棕色溶剂瓶中. 4.1.3含有乙腈的溶液以及不含乙腈但含有较高比例的其他有机溶剂的溶液在过滤时需使用有机相微孔滤膜,其它溶液在过滤时需使用水相微孔滤膜. 4.1.4存放清洗液、流动相、封柱液的溶剂瓶在每次装入溶液前需用少量过滤好的该溶液清洗数次. 4.2接通电源,开启连机电脑,再接通仪器电源,仪器自检完毕,处于准备进行状态.双击桌面图标“仪器1联机”,打开Agile nt 1200化学工作站,在左上角下拉框中选择“方法与运行控制”界面.显示如下图

标: 燈InatEU-ent I :方払和铤乔哲制 注意:一定要先双击“仪器1联机”图标,进入联机状态,方可双击“仪器1脱机”图标,同时进入脱机界面?否则,将无法联机. 4.2泵421准备清洗液并装入溶剂瓶中,将吸滤器放入瓶内.安装所需用柱子. 4.2.3将吹扫阀(即“Purge”阀)打开,单击泵图标—" 选择“设置泵”,将“流速”设置为3.00ml/min.选择清洗液所在通道(建议为A通道),单击“确定”,在“系统视图”中单击“启动” 运行泵,泵运行10分钟后,观察压力,应小于10bar,若大于此压力,应更换purge阀滤芯,调节流速1.00ml/min.

Agilent1200型高效液相色谱仪操作手册

Agilent 1200 LC (中文版 B01.01) 现场培训教材 安捷伦科技有限公司 生命科学与化学分析仪器部

一、培训目的: ●基本了解1200LC硬件操作。 ●掌握化学工作站的开机,关机,参数设定,学会数据采集,数据分析的基本操作。 二、培训准备: 1、仪器设备:Agilent 1200LC ●G1310A :(单元泵);G1312A(二元泵);G1311A(四元泵)。 ● G1313A(标准型自动进样器)。 ● G1316A(柱温箱)。 ● G1314A(VWD检测器)。 ● G1362A(示差检测器)。 ●色谱柱: Eclipse XDB-C18 150 x 4.6 mm, 5um column P/N 993967-902 2、溶剂准备: ●色谱级纯或优级纯乙腈或甲醇。 ●二次蒸馏水

基本操作步骤: (一)、开机: 1、打开计算机,进入中文Windows XP画面,并运行CAG Bootp Server程序。 2、打开 1200 LC 各模块电源。 3、待各模块自检完成后,双击“Instrument 1 Online”图标,化学工作站自动与1200LC 通讯,进入的工作站画面如下所示。 4、从“视图”菜单中选择“方法和运行控制”画面, 点击“视图”菜单中的“显示顶部工具栏”,“显示状态工具栏”,“系统视图”,“样品视图”,使其命令前有“√”标志,来调用所需的界面。 5、把流动相放入溶剂瓶中。 6、打开冲洗阀。 7、点击“泵”图标,点击“设置泵…”选项,进入泵编辑画面。 8 、设流速:5ml/min,点击“确定”。 9、点击“泵”图标,点击“控制…”选项,选中“启动”,点击“确定”,则系统开始冲洗,直到管线内(由溶剂瓶到泵入口)无气泡为止,切换通道继续冲洗,直到所有要用通道无气泡为止。 10、点击“泵”图标,点击“控制…”选项,选中“关闭”,点击“确定”关泵,关闭冲洗阀。 11、点击“泵”图标,点击“设置泵…选项”,设流速:1.0ml/min。 12、点击泵下面的瓶图标,如下图所示(以单元泵为例),输入溶剂的实际体积和瓶体积。也可输入停泵的体积,点击“确定”。

安捷伦1260型高效液相色谱仪详细操作规程

1.目的:规范Agilent 1260高效液相色谱仪维修、保养、校正操作。 2.适用范围:本公司化验室Agilent 1260高效液相色谱仪的维修、保养。 3.有关责任:化验室精密仪器室 4.引用标准:仪器说明书及Agilent化学工作者现场操作培训教材 5.规程内容: 5.1开机前准备 5.1.1根据实验要求配制流动相,须经0.45μm滤膜过滤,之后再进行脱气处理,使用前必须用超声波振荡l0-15min,按无机相和有机相分开别装入溶剂瓶A(装有洗盐装置,最好固定盛放无机盐水相)、B中;对照品和样品溶液进样前要经0.45μm滤膜过滤。 5.1.2若流动相中含有缓冲盐,则必须以每分钟2~3滴的速度虹吸10%的异丙醇水冲洗seal-wash,以防有盐结晶在泵头产生而损坏泵头。 5.2.采样前准备 5.2.1打开计算机,进入 Windows 系统, 从上到下依次打开各模块电源。5.2.2待各模块自检完成后,双击桌面上的“仪器1联机”图标,将自动进入化学工作站画面。 5.2.3从“视图”菜单中选择“方法和运行控制”画面,也可单击工作站画面左侧的“方法和运行控制”项,进入方法和运行控制窗口。 5.2.4打开Purge阀(逆时针),右击“泵”图标出现参数设定菜单单击“设定泵”选项进入泵编辑画面。 5.2.5设“流量”逐步增大流速至5ml/min ,A通道设到100%,单击“确

”。 5.2.6单击“泵”图标,出现参数设定菜单,单击“泵控制“选项选中“开”单击“确定”则系统开始Purge,直到管路内由溶剂瓶A到泵入口无气泡为止;切换B通道(B通道设到100%)继续Purge直到所有通道管路内均无气泡为止。(查看柱前压力,若大于10Bar,则应更换排气阀内滤芯/过滤白头。) 5.2.7将泵的流量设到0.5ml/min,若使用双泵则应设定溶剂配比,如A=80%,B=20%;关闭排气阀(顺时针);再将流量设到0.8ml/min,2分钟后设定至方法所需流速,冲洗色谱柱20-30min。 5.2.8单击泵下面的瓶图标,输入溶剂瓶A、B内流动相的实际体积(为保护泵和色谱柱,请按实际体积输入)和停泵的体积单击“确定”,如果各溶剂瓶溶剂体积小于停泵体积,泵将自动停止。 5.2.9把缓冲液(用于柱子过渡的,与流动相等比例的乙腈/水、甲醇/水或10%的水溶液)换成流动相,排气后,逐步增加至所需流速,待柱压基本稳定后,打开检测器等,观察基线情况。 5.3.数据采集 5.3.1采集方法编辑 5.3.1.1编辑完整方法:从“方法”菜单中选择“编辑完整方法”项,选中除“数据分析”外的三项,单击“确定”进入下一画面。 5.3.1.2方法信息:在“方法注释”栏中加入(如方法的用途等),单击“确定”进入下一画面。

安捷伦1260型高效液相色谱仪操作规程

安捷伦1260型高效液相色谱仪操作规程 开机 1.1 打开计算机,输入用户名和密码,进入Windows XP画面。 1.2 打开1260 LC 各模块电源(不分先后)。待各模块自检完成后,双击“仪器2联机”图标,化学工作站自动与1260 LC通讯,进入工作站。(注意:在“仪器2脱机”关闭的情况下,“仪器2联机”方能打开。) 1.3 从“视图”菜单中选择“方法和运行控制”画面,来调用所需的界面,正常情况会默认进入此界面。 1.4 确保对应溶剂瓶装入所要使用的流动相,左击“四元泵”模块下的“溶剂瓶”图标或右击“四元泵”下选择“瓶填充”,输入溶剂的实际体积和瓶总体积,可输入停泵的体积。单击“确定”。(注意:此操作很重要,以免气泡进入系统)。 1.5 轻轻旋开泵上的冲洗阀(缓缓旋开约1/4即可,不可用力太过)。右击“四元泵”图标,出现参数设定菜单,单击“方法”选项,进入泵编辑画面。设流量6ml/min,溶剂A设到100%;单击“确定”。右击“四元泵”图标,选择“控制”选项,选中“打开”,单击“确定”,则系统开始排气,直到管线内(由溶剂瓶到泵入口)无气泡为止;切换到通道同法继续排气,直到所有要用通道无气泡为止(只需排所用到的通道即可)。

1.6 右击“四元泵”图标,出现参数设定菜单,单击“方法”选项,进入泵编辑画面。设流量为:0ml/min,单击“确定”,轻轻关闭排气阀(旋紧即可)。 2. 数据采集方法、系列编辑: 2.1 编辑完整方法: 2.1.1. 从“方法”菜单中选择“编辑完整方法” 项,选中除“数据分析”外的三项,单击“确定”,进入下一界面“方法注释”。 2.1.2. 方法信息: 在“方法注释”中写入方法的相关信息。此项可忽略不写,单击“确定”,进入下一界面“选择进样源/位置”。 2.1. 3. 自动进样器参数设定: 选择“Als”的进样方式,单击“确定”,进入下一界面“设置方法”。 2.1.4. 方法参数设定: 在“设置方法”界面选择“四元泵”选项,在“流量”处输入所需流量,如:1ml/min,在溶剂“B”、“C”、“D”处输入流动相所占比例(A=100-B-C-D),也可在右侧“时间表”项下选择“添加”,编辑梯度。在“停止时间”项下输入样品运行时间,在“压力限值”输入柱子的最大耐高压,如300bar,以保护柱子。

安捷伦1260高效液相色谱仪操作规程

安捷伦1260高效液相色谱仪操作规程 一、开机 (1)打开计算机,登陆windows操作系统。 (2)打开主机各模块电源(从上至下),待各模块完成自检后,再双击桌面“仪器1联机”图标,进入化学工作站,从视图菜单中选择“方法和运行控制” 画面。 (3)进行仪器配置,点仪器-仪器配置-选择所需模块-自动配置-输入IP地址:192.168.254.11。把各流动相放入相应的溶剂瓶中。 (4)编辑方法。方法-新建方法-方法-编辑完整方法-编辑各项(四元泵、TCC、VWD、仪器曲线参数设定,仪器参数默认),完成后,文件→方法另存为→编辑名称,保存方法。 (5)排气。旋开排气阀(逆时针),右单击“四元泵”图标出现快捷键,点击“方法”设置泵流速,排气可设置1.2ml/min,l流量梯度100,也可5ml/min,流量梯度10。一般冲洗3-5min,注意倾斜储液瓶使过滤头处的气体进入 管道才可使气体排出,观察管路中气体位置,以其排净为目的。关泵,关 闭排气阀(顺时针)。(注意:先开排气阀,再开泵,先关泵,后关排气阀)。(6)在让液体进入柱子之前应将甁填充设置为实际值,谨防空进。将泵流速设置1ml/min,用过渡液即缓冲液冲洗色谱柱20—30分钟。 (7)换流动相,待柱前压力基本稳定后,打开检测器,视图,在线信号,选择信号,观察基线情况。 二、数据采集信息编辑及进样 (1)编辑样品信息:点“单次样品”小瓶,或点击运行信息-单次进样,设定操作者姓名,样品数据文件名,进样量等。 (2)编辑好样品信息后方可进样。 三、数据处理 (1)打开桌面“仪器1脱机”,单击“数据分析”进入数据分析画面。 (2)从“文件”菜单中选择调用信号,选择您的数据文件名,单击确定。(3)谱图优化。从“图形”菜单中选择“信号选项”从范围中选择“自动量程” 及合适的显示时间,或选择“自定义量程”调整,反复进行,直到图比例

安捷伦高效液相色谱仪操作说明

安捷伦高效液相色谱仪操作说明 一、校枪及样品处理 1. 校枪 仪器:两个小烧杯、分析天平、移液枪1000μL、100μL 步骤:打开分析天平预热,一只烧杯放到称量盘上调零,一只装入纯水。将移液枪1000μL、100μL调至950μL、50μL,分别吸取纯水称质量,如偏大或偏小,调节移液枪直至准确到0.001g。(如枪使用过久或气密性不好,可以准备一个小烧杯装入纯水,每次先轻轻沾湿枪口,甩掉水或在用卫生纸吸取口上的水,再插上枪头使用。)注意慢吸慢放,不要挂珠。2. 样品处理:用1.5mL离心管取0.5mL发酵液,取出样品后,首现在离心机上离心(13000rap/min 3min)。然后将样品稀释20倍,取950μL纯水、50μL发酵液于离心管中。混匀后在离心机上离心(13000rap/min 3min)。准备自动进样瓶(瓶中放上内衬管),取200μL待测液盖紧盖子。按顺序放到自动进样盘中。 二、开机 1、仪器各组件 将在线脱气器、泵:四元、进样器:自动进样器(六通阀)、柱温箱、检测器:示差折光检测器开关打开。 打开计算机,进入Windows XP 画面,并运行CAC Server程序,打开色谱仪各组件电源,待显示已联上各组件的信息及各模块自检完成后,双击Instrument 1 Online ,图标打开工作站。化学工作站自动与1200LC通讯。 流动相:将流动相(一般不主张使用偏酸、偏碱的流动相)放入溶剂瓶中,打开冲洗阀,设流速为2ml/min,单击确定,再依次单击泵→控制,选中启动,单击确定,则系统开始冲洗,至管路无气泡为止,切换管路反复操作至所需管路均无气泡。在“控制”选项中选“关闭”,关闭泵,关闭冲洗阀。单击泵下面瓶图标,输入溶剂的实际体积和瓶体积。 每次四元泵开始前,要打开冲洗阀阀门以5ml/min的流速冲洗10分钟,使脱气机与泵之间的流动相从冲洗阀流出,以免隔夜的流动相损伤色谱柱。 每次进样检测前,要用流动相冲洗色谱柱30分钟,达到柱温前20min流速设为 0.2ml/min,达柱温后再改为0.6ml/min。待1—1.5h检测器的基线稳定方可进行进样检测;检测结束后,色谱柱要先用水冲洗20分钟,然后用甲醇或乙腈冲洗至少20分钟,以延长色谱柱的使用寿命。绝对禁止偏酸、偏碱的流动相以及缓冲液在色谱柱中过夜。 三、编辑分析方法 新方法建立:程序菜单显示绿色,即可进行参数设置及操作 泵参数设定:设定流速、比例、运行时间、平衡时间、泵辅助设定(梯度)等。 点击确定进入下一画面 自动进样器参数设定:设定进样量(5μL)、抽取位置(调节针高度3.0mm)、进样方式等。“序列”→序列参数→子目录(日期:年月日时间) “序列表”:插入/批量输入向导→“追加”、“插入”→“样品位置”、“开始位置”、“增量”、“插入行数” 标准进样:只能输入进样体积,此方式无洗针功能。 抽取位置:3.0mm 洗针进样:可以输入进样体积和洗瓶位置此方式针从样品瓶抽完样品后会在洗瓶中洗针。

安捷伦1260高效液相操作规程

安捷伦1260高效液相操作规程

安捷伦液相1260高效液相色谱 操作规程 1.前期工作 查找资料(最好是外文文献)了解别人做该样品时常用的流动相和固定相。如果还不清楚样品是什么物质,最起码也应该对其极性进行了解,为选择合适的流动相和固定相打好基础。 流动相选择注意事项: ①避免使用高粘度的溶剂作为流动相; ②所选用的流动相一定要与样品相溶; ③各流动相之间可以很好的相溶; 固定相选择注意事项: a.正相色谱 正相色谱用的固定相通常为硅胶(Silica)以及其他具有极性官能团胺基团,如(NH2,APS)和氰基团(CN,CPS)的键合相填料。由于硅胶表面的硅羟基(SiOH)或其他极性基团极性较强,因此,分离的次序是依据样品中各组分的极性大小,即极性较弱的组份最先被冲洗出色谱柱。正相色谱使用的流动相极性相对比固定相低,如正已烷(Hexane),氯仿(Chloroform),二氯甲烷(Methylene Chloride)等。 b.反向色谱 反向色谱用的填料常是以硅胶为基质,表面键合有极性相 对较弱官能团的键合相。反向色谱所使用的流动相极性较强,通常为水、缓冲液与甲醇、乙腈等的混合物。样品流出色谱柱的顺序是极性较强的组分最先被冲洗出,而极性弱的组分会在色谱柱上有更强的保留。常用的反向填料有:C18(ODS)、C8(MOS)、C4(Butyl)、C6H5(Phenyl)等。

2.准备工作 ①用于液相色谱分析的样品溶液使用前要经过0.15μm过滤器过滤,必须达到均匀而无颗粒的状态; ②流动相一定要选用色谱级别的(最好是默克、飞世尔、时联等牌子的),并且在使用之前一定要使用0.4μm过滤器过滤,再用超声波清洗仪脱气处理20-30min; ③在连接柱子和色谱仪之前,阀件或管路一定要清洗干净,(一般用异丙醇将管路清洗) 3.仪器操作 (一)将所选择的流动相加入相应的试剂瓶中:棕色瓶对应A泵,该瓶中只能加双蒸水或娃哈哈纯净水;B、C、D泵根据需要添加。 注:若流动相中有水、乙腈最好现用现处理,不宜放置太长时间。 (二)先打开计算机登陆windows操作系统,再将仪器的泵、色谱柱、检测器打开,待计算机界面显示连接好后,双击桌面“联机”图标,进入化学工作站,从“视图”菜单中选择“方法和运行控制”画面。

Agilent1260高效液相色谱仪操作规程

Agilent1260高效液相色谱仪操作规程 1开机前准备 1.1根据实验要求配制流动相,须经0.45μm滤膜过滤,之后再进行脱气处理,使用前必须用超声波振荡l0-15min,按无机相和有机相分开别装入溶剂瓶A(装有洗盐装置,最好固定盛放无机盐水相)、B 中;对照品和样品溶液进样前要经0.45μm滤膜过滤。 1.2若流动相中含有缓冲盐,则必须以每分钟2~3滴的速度虹吸10% 的异丙醇水冲洗seal-wash,以防有盐结晶在泵头产生而损坏泵头。 2 开机 2.1打开电源,打开计算机,进入Windows 系统,从上到下依次打开各模块电源。 2.2待各模块自检完成后,双击桌面上的“仪器1联机”图标,将自动进入化学工作站画面。 2.3从“视图”菜单中选择“方法和运行控制”画面,也可单击工作站画面左侧的“方法和运行控制”项,进入方法和运行控制窗口。2.4打开Purge阀(逆时针),右击“泵”图标出现参数设定菜单单击“设定泵”选项进入泵编辑画面。 2.5设“流量”逐步增大流速至5ml/min ,A通道设到100%,单击“确定”。 2.6单击“泵”图标,出现参数设定菜单,单击“泵控制“选项选中“开”单击“确定”则系统开始Purge,直到管路内由溶剂瓶A 到泵入口无气泡为止;切换B通道(B通道设到100%)继续Purge

直到所有通道管路内均无气泡为止。(查看柱前压力,若大于10Bar,则应更换排气阀内滤芯/过滤白头。) 2.7将泵的流量设到0.5ml/min,若使用双泵则应设定溶剂配比,如 A=80%,B=20%;关闭排气阀(顺时针);再将流量设到0.8ml/min ,2分钟后设定至方法所需流速,冲洗色谱柱20-30min。 2.8单击泵下面的瓶图标,输入溶剂瓶A、B内流动相的实际体积(为保护泵和色谱柱,请按实际体积输入)和停泵的体积单击“确定”,如果各溶剂瓶溶剂体积小于停泵体积,泵将自动停止。 2.9把缓冲液(用于柱子过渡的,与流动相等比例的乙腈/水、甲醇/水或10%的水溶液)换成流动相,排气后,逐步增加至所需流速,待柱压基本稳定后,打开检测器等,监视基线。 3数据采集 3.1采集方法编辑 3.1.1编辑完整方法:从“方法”菜单中选择“编辑完整方法”项,选中除“数据分析”外的三项,单击“确定”进入下一画面。 3.1.2方法信息:在“方法注释”栏中加入(如方法的用途等),单击“确定”进入下一画面。 3.1.3泵参数设定:在“流速”处输入方法所需流量(如1ml/min);默认为A为100%,如需二元高压,在“溶剂B”处输入所需比例,则溶剂A=100-B ,也可“插入”一行“时间表”编辑二元梯度;在“压力限”处输入柱子的最大耐高压(建议设定200bar)以保护柱子,单击“确定”进入下一画面。

Agilent-1200高效液相色谱培训材料使用说明书

Agilent 1200 LC [Agilent Chemstation B.04.02 Classic (中文)] 现场培训教材 安捷伦科技有限公司

一、 目录 二、 培训目的 (3) 三、 培训准备 (3) 1. 仪器准备 (3) 2. 溶剂准备 (3) 四、 方法建立 (3) 1. 开机准备 (3) 2. 数据采集方法编辑 (5) 9 G1310A(单元泵) (5) 9 G1312A,G1312B XL(二元泵)/G1311A(四元泵): (7) 9 G1313A(标准型自动进样器),G1329A/B(自动控温自动进样器) (8) 9 G1367B/C/D(高性能自动进样器) (9) 9 G1328A(手动进样器) (11) 9 G1316A,G1316B XL(柱温箱) (11) 9 G1314A/B/D/E,G1314C XL(可变波长紫外检测器) (13) 9 G1315B/D ,G1315C XL(二极管阵列检测器)/ G1365B/D ,G1365C XL(多波长紫外检 测器) (15) 9 G1362A(示差检测器) (17) 9 G1321A(荧光检测器) (19) 9 G4218A(蒸发光散射检测器) (23) 3. 数据分析方法编辑 (25) 9 谱图优化 (25) 9 积分参数优化 (25) 9 校正 (27) 9 打印报告 (28) 9 光谱 (29) 4. 建立全新完整方法向导 (31) 9 新建完整方法: (32) 9 保存方法: (36)

9 保存即时改变的方法 (36) 9 调用方法: (36) 5. 进样 (36) 9 单针进样 (36) 9 序列进样 (37) 五、 关机 (37) 1. 关闭检测器的灯 (41) 2. 冲洗系统 (41) 3. 封存色谱柱 (41) 4. 关闭电脑 (41) 5. 关闭模块 (41) 六、 RRLC(快速液相)注意事项 (41) 七、 Agilent 1200保养维护 (43) 八、 Agilent 1200常见问题解决方法 (45)

1260 lnfinity II 型安捷伦高效液相色谱仪使用及维护保养操作规程

1 目的 规范安捷伦高效液相色谱仪及安捷伦Openlab 2.X 工作站的使用和维护。 2 适用范围 本规程适用于1260 lnfinity II 型安捷伦高效液相色谱仪及安捷伦Openlab 2.X 工作站的使用和维护。 3 编写依据 1260 lnfinity II 安捷伦高效液相色谱仪及安捷伦Openlab 2.X 工作站(安捷伦科技(中国)有限公司)使用说明书。 4 职责 4.1 仪器设备负责人负责对本标准操作规程的监督执行。 4.2 实验操作人员负责对本标准操作规程的具体执行。 5 内容 5.1 使用OpenLAB 控制面板设置和配置: 5.1.1首次使用,以管理员权限账户登录控制面板: 点击桌面图标,输入管理员账号与密码登录。 5.1.2在控制面板导航窗格,选中管理,可根据实际需要:创建/编辑“角色”,创建不同权限“用户”,编辑“安全策略”等。 5.1.3 OpenLAB 2.X 是基于项目为主导的使用,须先创建“项目”: (1)导航窗格选中项目,创建 “项目”; (2)在“CDS 设置”,可根据需要做必要设置(如开启审计跟踪等):提示:“结果”的审计跟踪是默认开启的; (3)创建在桌面创建项目分析(数据处理)的快捷方式:点击菜单栏, 5.1.4创建仪器并配置: (1) 导航窗格选中仪器,创建 “仪器”

(2) 配置仪器:通过仪器IP地址或主机名配置仪器: (3)添加或移除使用这个仪器的用户: 点击编辑权限点击添加或移除用户、组。 (4)设置LC自动关闭检测器: 可通过管理/仪器选项,设置关闭检测器的时间:(可先编好一冲柱方法和停泵方法(流速设为0ml/min),加在序列表最后,即可实现自动冲柱、停泵和关闭氘灯) 5.2联机操作、运行样品: 5.2.1 LC开机:开启LC各模块; 5.2.2开电脑,点击后桌面快捷图标,进入仪器控制界面(或从控制面板启动),在功能区/状态,仪器状态版面,点击总启动按钮启动仪器。“重置”可回复默认状态 5.2.3编辑方法:选中功能区/方法,可新建,调用(已有方法),保存,另存,上传、下载仪器运行方法:注:方法参数设置完成后须保存或另存方法,并下载到仪器。 (1)平衡仪器:在该方法下平衡仪器(柱子及灯),直至10分钟内基线漂移不超过0.5mAu(VWD),且仪器各模块(功能)均为绿色就绪状态; (2)运行单个样品(单针进样):选中功能区/单个样品,在“运行信息”、“自动进样器”、“处理部分”等填入样品相关信息,并运行(采集数据); (3)运行序列样品(多针连续自动进样): 选中功能区/序列,在序列表中填入各样品对应信息,并运行。若需运行后关机,可通过控制面板/管理/仪器选项,设置关闭检测器的时间,再提前编好冲柱方法和停泵方法(流速设为0ml/min),加在序列表最后,即可实现自动冲柱、停泵和关闭氘灯。 (4)在运行中若需编辑序列(添加、删除序列行),点编辑后须“更新”或“取消”,否则序列将不会运行当前进样之下的序列行。 5.2.4冲柱和关机: (1) 不使用缓冲盐时:可直接用100%甲醇冲洗系统30 分钟以上。 (2)使用缓冲盐时: (a)10%甲醇+90%水冲洗系统60分钟以上; (b)逐步过渡到100%有机相再冲洗系统30 分钟以上。 (c)冲柱时可关闭灯: 运行预先编好的冲柱方法和停泵方法实现(在序列最后设置)。 5.2.5 退出工作站,关闭LC各模块电源,关闭电脑。 5.3数据分析: 5.3.1 面积百分比: 点击Da图标“项目”进入数据分析,点击左下角导航栏的“数据选择”,并双击选择要处理的数据

安捷伦1260高效液相操作规程

安捷伦液相1260高效液相色谱 操作规程 1?前期工作 查找资料(最好是外文文献)了解别人做该样品时常用的流动相和固定相。如果还不清楚样品是什么物质,最起码也应该对其极性进行了解,为选择合适的流动相和固定相打好基础。 流动相选择注意事项: ①避免使用高粘度的溶剂作为流动相; ②所选用的流动相一定要与样品相溶; ③各流动相之间可以很好的相溶; 固定相选择注意事项: a.正相色谱 正相色谱用的固定相通常为硅胶(Silica)以及其他具有极性官能团胺基团,女口(NH2,APS)和氰基团(CN,CPS)的键合相填料。由于硅胶表面的硅羟基(SiOH)或其他极性基团极性较强,因此,分离的次序是依据样品中各组分的极性大小,即极性较弱的组份最先 被冲洗出色谱柱。正相色谱使用的流动相极性相对比固定相低,如正已烷(Hexane),氯仿(Chloroform),二氯甲烷(Methylene Chloride) b.反向色谱 反向色谱用的填料常是以硅胶为基质,表面键合有极性相对较弱官能团的键合相。反向色谱所使用的流动相极性较强,通常为水、缓冲液与甲醇、乙腈等的混合物。样品流出色谱柱的顺序是极性较强的组分最先被冲洗出,而极性弱的组分会在色谱柱上有更强的保留。常用的反向填料有:C18(ODS)、C8(MOS)、C4(Butyl)、C6H5(Phenyl)等。

I 2?准备工作 ① 用于液相色谱分析的 样品溶液使用前要经过0.15 m 过滤器 过滤,必须达到均匀而无颗粒的状态; ② 流动相一定要选用色谱级别的(最好是默克、飞世尔、时联 等牌子的),并且在使用之前一定要使用0.4 m 过滤器过滤,再用超 声波清洗仪脱气处理20-30min ; ③ 在连接柱子和色谱仪之前,阀件或管路一定要清洗干净,(一 般用异丙醇将管路清洗) 3?仪器操作 (一)将所选择的流动相加入相应的试剂瓶中:棕色瓶对应 A 泵,该瓶中只能加双蒸水或娃哈哈纯净水; B 、C 、D 泵根据需要添 加。 注:若流动相中有水、乙腈最好现用现处理,不宜放置太长时间 (二)先打开计算机登陆 windows 操作系统,再将仪器的 泵、色谱柱、检测器打开,待计算机界面显示连接好后,双击桌 面“联机”图标,进入化学工作站,从“视图”菜单中选择“方 法和运行控制”画面。 Pl. EKflEi ?〒斗聊 碎F 七上 **!-!

相关文档