HP刀片服务器简单操作详解

HP刀片服务器简单操作讲解
? 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice

Content
刀片系统机箱类型,各部分主件与配件 C7000机箱前视图 C7000机箱后视图 部件安装与规则
C7000系统详解
互连模块与服务器端口映射 刀片系统线缆连接 OA access and setup 故障诊断 操作系统安装 资源访问链接
C3000系统简介
2

c-Class刀片服务器系统—C7000机箱
? 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice

刀片系统机箱类型,各部分主件与配件
机箱类型
4

C-Class刀片服务器有下列主件及配件
电源模块
c-Class刀片机箱
冷却风扇 网络互连模块
5
刀片服务器

c7000 enclosure — Front
? Two blade form factors
? Full-height server blade (up to 8 per enclosure) ? Half-height server blade (up to 16 per enclosure) ? Half-height storage blade (up to 90 drives per enclosure)
HH server blade 2P FH server blade 2P/4P HH storage blade Up to 420GB
? Power supplies
? Up to 6 hot-plug power supplies @ 2250W
? Management
? BladeSystem Insight Display ? Onboard Administrator
Insight Display
6
Hot-plug power supplies

c7000 enclosure device bay numbering
Full-height device bay numbering
Half-height device bay numbering
7

c7000 enclosure — Rear
Hot-plug redundant fans Eight interconnect bays
Network and serial connectors
8
Enclosure links Redundant Onboard Administrators
3+3 C19 cords

c7000 enclosure interconnect bay numbering
9

c-Class enclosure fan numbering
10

c-Class enclosure PS numbering
6
1-6
5 4
3
2 1
3+3电源冗余,C19型接头
11

部件安装与规则
安装电源
C7000刀片机箱后视图,交流电输入方式
6
1-6
5 4
3
2 1
3+3电源冗余,C19型接头
12

电源安装规则
HP 建议根据所配的电源模块数量,按下列方式装配
Zone 1 Blade (from front of unit) PS = N PS = N+1 PS = N+N
Zones 1-2
Zones 1-3
Zones 1-4
13

电源安装
1.打开电源支架扣
注意:在安装全部6个电源模块 时,请将Insight Display左右滑动, 以便于安装.
2.从刀片机箱前部插入机箱,并扣上支架扣
14

风扇安装
C7000机箱提供4-10个冗余风扇
1
2
3
4
5
HP推荐在配置风扇 时,遵守下列规则:
a.2个风扇时,插到 4、5和9、10 b.6个风扇时,插到3、 4、5和8、9、10 c.8个风扇时,插到1、 2、4、5和6、7、9、 10 d.10个风扇时插满风 扇插槽
注意:风扇安置不对, 会造成噪声过大
6
7
8
9
10
风扇分二层,上部分1-5(从左到右),下部分6-10
15

16

风扇安装
1.按下风扇挡板扣,取出风扇挡板
2.插入风扇
17

刀片服务器安装(全高)
惠普C7000刀片服务器机箱提供了四个隔板,用来支持半高的刀片服务器, 当要插入全高服务器时,需要取下对应的隔板
1.取下服务器挡板
18

刀片服务器安装(全高)
2.向左推动,打开锁扣 3.向内推横隔板到头, 将横隔板右边向上提, 使横隔板脱离右竖隔 板,再顺时针方向旋转
4.抬高横隔板左边,使 横隔板脱离左竖隔板, 从机箱中取出横隔板
19

刀片服务器安装(全高)
1.打开刀片服务器扣 2.将刀片服务器插入机箱到底,上扣 3.将服务器挡板,插入空置服务器槽位
20

服务器系统维护操作手册-(14121)

青岛金欧利营销有限公司操作手册 文件名称:服务器系统维护操作手册 编号: G-WI/630-06-020 版本号: 1/0 编制人:刘鹏 审核人:季忠凯 批准人: 生效日期:

4.2 修改页:如下所示 修改记录

流程图 无

1. 目的 通过规范服务器系统维护操作,降低服务器系统维护过程中可能带来的业务风险。 2. 适用范围 本文件适用于青岛金欧利营销有限公司信息部。 3. 术语 3.1 服务器系统:公司各服务器及与服务器相连的外设和存储设备。 3.2 主服务器系统:指小型机服务器及与其相连的外设和存储设备。 3.3 次服务器系统:指除小型机外其它的服务器及与其相连的外设和存储设备。 4.职责 4.1信息部负责服务器系统的日常维护和管理。 5.管理内容: 5.1主服务器系统维护手册 5.1.1CRM服务器维护手册 5.1.1.1文件系统检查 # df -k Filesystem 1024-blocks Free %Used Iused %Iused Mounted on /dev/hd4 10485760 5143096 51%9495 1% / /dev/hd2 10485760 8014948 24%49885 3% /usr /dev/hd9var 10485760 9975400 5%9787 1% /var /dev/hd3 10485760 8773232 17%973 1% /tmp /dev/hd1 10485760 10478148 1%22 1% /home /proc - - - - - /proc /dev/hd10opt 5242880 4929636 6%10244 1% /opt /dev/fslv01 1569718272 1450676488 8%69989 1% /bi /dev/fslv00 941621248 858313640 9%57596 1% /crm 检查内容:红色字体Used部分,如果有超过85%,说明文件系统需要扩容或者检查为什么超出。 5.1.1.2查看系统故障记录收集 # errpt IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION B6267342 0709235512 P H hdisk10 DISK OPERATION ERROR B6267342 0708235512 P H hdisk10 DISK OPERATION ERROR B6267342 0707235512 P H hdisk10 DISK OPERATION ERROR B6267342 0706235512 P H hdisk10 DISK OPERATION ERROR B6267342 0705235512 P H hdisk10 DISK OPERATION ERROR 检查内容:如果有错误内容将会显示出来,例如B6267342就是一个错误(此错误可以不考虑,其一直存在)。

Hp刀片服务器VirtualConnect特性介绍

Hp 刀片服务器Virtual Connect特性介绍 惠普虚拟连接按照其实现的功能不同,可以分为 Converged Networking、Ethernet和Fiber Channel三个不同的系列,针对这三个系列,惠普为用户提供多元化的I/O虚拟解决方案。Ethernet VC可以提供以太网虚拟化; Fiber Channel VC可以提供FC存储的虚拟化;Converged Networking VC 单模块就可以实现以太网和存储的虚拟化。 Virtual Connect Module Converged Networking HP VC Flex Fabric 10Gb/24-PortModule //Enet 和FC混合模块 Ethernet HP 1/10Gb VC-Enet Module HP 1/10Gb-F VC-Enet Module HP VC Flex-10 Enet Module Fiber Channel HP 4Gb 20Port VC-FC Module HP 8Gb 20Port VC-FC Module HP 8Gb 24Port VC-FC Module

、 VC-Enet 配置 配置VC-enet基本流程:首先给一台blade定义一个profile,然后定义2个虚拟网络,分别指定这个网络的uplink 和downlink,最后把profile assign给一台刀片即可。 1.物理连接,通常物理连接如图所示: Figure 1 Aggregating NIC Bandwidth Using Team (TLB) and SmartLink 2.网络配置说明 a.Server NIC1 和NIC2之间做APA(Fail over), windows主机做Team 。 b.VC与客户交换机之间链路做trunk (cisco叫port channel),VC-Enet模块无需配置 LACP协议,VC模块自动提供LACP功能。 c.配置 net1,net2 为smart link(等同于上层端口检测),如果uplink连接失效,vc会自动断 开downlink连接,从而保证APA可以failover至另一网卡。详细配置及fail over说明见 58页VC-Enet_cook_book。 3.初始化VC配置过程

HP服务器型号

1. HP ProLiant DL 服务器 2. HP ProLiant ML 服务器 ProLiant BL 刀片式服务器 (HP Blade System 刀片服务器系统) 其中DL服务器就是机柜式服务器,ML服务器是塔式服务器,BL既刀片服务器. 惠普服务器的型号一般为DL(or ML or BL)字母+数字 如ML110 中ML为机型是塔式服务器 110为机器编号后面再开发的为G2,再开发为G3如此类推,既第2代,第3代. 如DL 380 G4 中DL为机柜式服务器 380为机器编号 G4为基于DL380开发的第四代服务器. 惠普的每个产品都有相对应的商品编码:一般类似为 417453-AA1(此为DL 380 G5 服务器的编码). 而根据主板平台即CPU的不同分为Intel平台和AMD平台,在命名上的差别就体现在命名的最后一位。 Intel平台服务器使用尾数为0的命名方式,而AMD平台则尾数为5. 如ML110与ML115的区别就在于主板平台的不同。 同样DL160与DL165, DL180与DL185都有着这样的区别。 惠普服务器分类 ProLiant 系列服务器 » HP ProLiant DL 机架服务器 » HP ProLiant ML 塔式服务器 » HP Proliant BL 刀片服务器系统 Integrity 动能服务器 » HP Integrity入门级服务器 » HP Integrity中高端服务器 » HP Integrity高端服务器 » HP Integrity BL 刀片服务器 Integrity NonStop 容错服务器 » HP 9000服务器 » 电信级服务器 4.按操作系统分类 » x86 » HP-UX 11i » Intel® Itanium® 2 » Windows® » PA-RISC » Linux » Alpha » OpenVMS » NonStop OS » Tru64 UNIX 5.按处理器类型分类

惠普刀片服务器硬件安装配置手册

HP-刀片服务器 - 硬件配置安装手册第一技术分册 惠普刀片服务器硬件安装配置手册 ——VER 2.0

目录 第 1章刀片服务器硬件配置 (5) 第 2章刀片服务器硬件描述 (6) 2.1刀片服务器机箱HP C7000 (6) 2.2刀片服务器描述 (8) 2.3刀片 C3020网络交换机 (10) ISCO 2.4刀片 B 4/24 SAN交换 机 (11) ROCADE 第 3章刀片服务器和机箱的连接. (12) 第 4章刀片服务器的安装 (14) 第 5章刀片服务器内存的配置 (16) 第 6章刀片服务器硬盘的安装 (17) 第 7章刀片网络交换机配置 (19) 7.1通过计算机连接交换机 . (19) 7.2完成快速安装页面的设置 (20) 7.3网络连接和配置 (22) 7.3.1网络拓扑结构 (22) 7.3.2网络地址规划和端口配置表 (23) 7.3.3网络配置 (24) 第 8章刀片存储交换机配置 (26) 8.1设置存储交换机IP 地址 (26) 8.1.1采用串口连接进行设置 (26) 8.1.2通过超级终端命令行的方式访问存储交换机 (26) 8.1.3设置存储交换的 IP 地址 (26) 8.2配置存储交换机 (27) 8.2.1设置时间 (27) 8.2.2Disabling/enabling存储交换机 (27)

8.3更改交换机的F IBRE C HANNEL DOMAIN ID (28) 8.4检查交换机工作状态和配置信息 (28) 第 9 章刀片服务器的配置 (29) 9.1配置刀片机箱IP 地址 (29) 9.2通过刀片机箱IP 地址,登录刀片进行配置 (30) 第 10 章刀片服务器的检测 (37) 10.1硬件安装配置检测 (37) 10.2硬盘装配正常检验 (38) 10.3操作系统正常安装检验 (38) 10.4刀片服务器安装检查表 (39)

HP刀片服务器 虚拟化整合解决方案

目录 1.服务器硬件整合.................................................................................................................... - 2 - 1.1什么是服务器整合........................................................................................................ - 2 - 1.2 为何要做服务器整合................................................................................................... - 2 -2.刀片服务器的概念................................................................................................................ - 3 -3.刀片服务器如何整合IT资源.............................................................................................. - 4 - 3.1 新一代数据中心对IT设施系统架构的要求 ............................................................. - 4 - 3.2 HP 刀片系统产品线..................................................................................................... - 6 - 3.3 刀片系统三大创新技术............................................................................................... - 7 - 3.3.1 洞察管理技术(Insight Control).................................................................... - 7 - 3.3.2 能量智控技术(Thermal Logic).................................................................... - 8 - 3.3.3 虚拟连接技术(Virtual Connect) .................................................................. - 8 -4.HP刀片服务器产品解决方案.............................................................................................. - 9 - 4.1 服务器整合管理........................................................................................................... - 9 - 4.2 最佳的服务器集群..................................................................................................... - 10 - 4.3 数据中心设备变更管理............................................................................................. - 11 -5.虚拟计算技术...................................................................................................................... - 13 -6.为什么要用虚拟化技术...................................................................................................... - 15 -7.HP虚拟化产品方案及配置模块........................................................................................ - 16 - 7.1 HP-VMware服务器虚拟架构解决方案 .................................................................... - 16 - 7.1.1 Virtualization Platforms .................................................................................... - 16 - 7.1.2 USB内嵌版Vmware 3i ................................................................................... - 18 - 7.1.3 V I高效管理和智能模块................................................................................. - 18 - 7.2 HP能够提供更全面的虚拟计算IT基础设施环境 .................................................. - 20 - 7.2.1 HP VMM虚拟化管理软件包.......................................................................... - 20 - 7.2.2 VSE服务器虚拟环境解决方案 ...................................................................... - 21 -8.本方案推荐采用虚拟化技术场景...................................................................................... - 22 - 8.1服务器整合Server Consolidation .............................................................................. - 24 - 8.2业务连续Business Continuity ................................................................................... - 25 - 8.2.1无需原硬件的专业数据恢复........................................................................... - 25 - 8.2.2基于虚拟机的集群简化方案........................................................................... - 26 - 8.2.3服务器迁移和自动化....................................................................................... - 28 -9.虚拟化服务器整合带来的好处.......................................................................................... - 29 -10.HP刀片平台部署虚拟化整合解决方案.......................................................................... - 31 -

EXCEL服务器操作手册

EXCEL服务器操作手册 目录 一、系统安装及访问...................................................................................................................- 2 - 1.1客户端安装.....................................................................................................................- 2 - 1.2客户端登录方式.............................................................................................................- 2 - 1.3 Web登录方式 ................................................................................................................- 3 - 二、用户类型及权限...................................................................................................................- 4 - 2.1用户类型及权限.............................................................................................................- 4 - 三、客户端使用说明...................................................................................................................- 5 - 3.1填报流程.........................................................................................................................- 5 - 3.2查看流程.........................................................................................................................- 8 - 3.3汇总流程.........................................................................................................................- 8 - 四、Web端使用说明 ..................................................................................................................- 9 - 4.1填报流程.........................................................................................................................- 9 - 4.2查看流程...................................................................................................................... - 13 - 4.3汇总流程...................................................................................................................... - 13 -

服务器使用手册

Stratus ftScalable Storage 容错存储阵列使用说明书 Stratus Technologies By WD Yang , Stratus Shanghai Rep. Office, Dec 2007

一.安装前的准备 1.1、机箱外观 1.1.1机箱前部指示灯状态 从前面观察存储阵列,其控制机箱和扩展机箱是一样的。分为左耳、右耳和三排四列共十二个硬盘槽位。其中左耳有一个数字的 LED 指示灯,显示当前机箱的 ID,通常控制机箱的 ID 为 0,扩展机箱的 ID 为 1 或 2;右耳有四个 LED 指示灯; 1.1.2、机箱背部的各种端口及开关 从后面观察存储阵列,控制机箱和扩展机箱是不一样的;控制机箱的后面左右两端各有一个电源模块,分别带有各自的开关;中间有两个控制模块,分成上下排列,每个控制模块含有: ● 两个光纤接入端口(分别标记为0 号和1 号); ● 一个串行控制端口(可使用命令行界面CLI 来配置存储阵列); ●一个以太网控制端口(用于图形化界面GUI 配置存储阵列); ●一个SAS 扩展输出端口(用于连接扩展机箱)

1.1.3、机箱背部的指示灯状态 控制机箱背后的电源模块和控制模块上有许多LED 指示灯,分别指示当前的部件运行状态。其中电源模块上两个LED 灯,一个灯标示该电源是否已经开启,另一个灯标示电源模块上的输出和风扇是否正常。控制模块上LED 的含义见下表。

1.1.4 扩展机箱背部的各种端口及开关 存储阵列的扩展机箱背后,左右各有一个电源模块,每个电源模块上都有独立的开关;中间有两个I/O 模块,呈上下排列,每个I/O 模块上都有 ●一个SAS 数据输入端口(用于连接控制机箱或上一个扩展机箱的SAS 输出) ●一个SAS 扩展输出端口(用于连接下一个扩展机箱) ●一个串行控制端口CLI (扩展机箱上的CLI 端口不能被使用) 1.1.5扩展机箱背部的指示灯状态 存储阵列的扩展机箱背部的电源模块上两个LED 灯与控制机箱上的电源LED 指示灯一样,一个灯标示该电源是否已经开启,另一个灯标示电源模块上的输出和风扇是否正常 I/O 模块上的LED 指示灯含义如下:

HP刀片服务器操作系统系统安装方法

HP刀片服务器操作系统系统安装方法 安装了一台HP C7000 16片BL460C,由于HP C7000刀片中心机箱没有光驱设置,每台刀片的面板上都有一个热插拔VGA、KB USB和Mouse USB接口,可以连接到本地的显示器,键盘鼠标上,这和IBM的刀片中心有区别,IBM的刀片中心上带USB接口的键盘鼠标口(外面外形为PS/2),本地还带KVM切换器。HPC7000我总结了下,安装方法有以下几种: (1)用USB光驱,我没有安装成功,因为本地接口只有2个USB 接口和VGA接口,2个USB必须连接KB,Mouse,连接USB 光驱,必须要用USB HUB,由于我找到的USB HUB没有外置的电源,因此BL460C刀片服务器在启动过程中不认。建议用带外置电源的USB HUB测试下。 (2)安装HP Bladesystem 本身带的工具“HP Insight controld Data Center Edition”(8 ILO2 Demo license,30 Day Evaluator),利用RDP中的工具对服务器进行远程安装,在安装中我们可以利用C7000机箱本身带的OA-ILO2的administrator 全局用户对所有的刀片进行远程安装、管理等;在安装操作系统中,我们必须将本地的光驱(可以是虚拟光驱)、软驱的盘符通过OA -ILO2端口映射给远程的刀片服务器,进行操作系统的正常安装;

(3)利用每台刀片服务器本身带的ILO2 Administrator,用在系统启动时候查到的ILO2拿到的地址,用https://ILO2-IP,Administrator/随机带的Password,或者用F8进入ILO2管理菜单,修改Administrator密码,进行系统登陆后,就可以远程安装和管理操作系统了。 (4)只要安装后一台刀片,我们可以利用本身刀片带的Raid卡功能或者RDP的快速部署,利用热插拔硬盘将所有的刀片进行安装好。

惠普刀片服务器OA管理使用说明

惠普刀片服务器OA管理

第一部分:OA 管理模块 一、设置OA 的静态IP 地址: 1、设置下图中的Insight Display (管理显示屏); 2、在主菜单中, 移动光标到Enclosure Settings . 点击 OK . 3、选中“OA1 IP Adress ”并点击; Hot-plug power supplies Insight Display HH storage 2P/4P 2P

4、将OA1 Network 设成静态(Static); 5、设置OA1的IP地址、掩码、网关,然后点击OK接受。 二、用PC连接OA进行配置: 1、用网线将PC与OA模块上的管理网口(RJ45)相连;

2、打开IE ,输入刚才设定的OA IP 地址,在出现的网页中输入用户名:Administrator ,密码:****(OA 模块上有写有Password 的卡片)。 3、对OA 进行初始化配置: c7000 enclosure —Rear 3+3 C19 cords Hot-plug redundant Network and serial connectors Enclosure links Redundant Onboard Administrators

4、设置机柜名称和机箱名称; 5、添加管理用户和权限;

6、网络设置,应设置成静态IP 地址; 7、设置机箱内每个模块槽的IP 地址,即设置刀片服务器的ILO地址(设定起始地址即可,OA会自动从Bay1按顺序排列到Bay16)和网络模块的管理地址;

刀片服务器使用手册

刀片服务器使用手册 一、刀片服务器的介绍 刀片服务器是公司应用服务中的一部分,是在标准高度的机架式机箱内可插多个卡式的服务器单元,实现高可用和高密度。公司应用中使用的刀片服务器为HP 460C G6(以下简称刀片服务器)。刀片机每一块“刀片”实际上就是一块系统主板,可以通过“板载”硬盘启动自己的操作系统,在集群中插入新的“刀片”就可以提高整体性能。 二、部署情况 刀片服务器网络拓扑结构配置如图:其中每台刀片服务器各有两个网卡,分别连接到每台刀片的交换机上再各通过一条 光纤线路连接到核心交换机上。 三、刀片服务器的配置 1、配置刀片机箱IP地址 使用HP c-class bladc server的OA远程管理端口安装设备onboard administrator card .

1) 通过小液晶屏设置OA的IP地址:先选中enclosure settings 2) 进入enclosure settings后,设置OA IP Address 192.168.1.1设置完成后选Accpect all 2、通过刀片机箱IP地址,登录刀片进行配置

1)通过终端IE6.0浏览器输入刀片服务器的OA口的IP地址:192.168.1.1;输入机器前方的纸片的出厂OA的用户名和密码登录。 2)登录后进入Rack Overiew界面,把刀片的硬件状态以图片方式展现 3)第一次安装c-class刀片,直接进入first time setup wizard

4)进入Configuration Management,快速重载配置好的OA设置 5)Rack and Enclosure Settings,设置名称、时间、时区等 6)Administrator Account Setup设置管理员账户,PIN protection可以启用设置PIN Code来给刀片前面的液晶屏设置密码

刀片服务器的优点与缺点(行业参考)

刀片服务器有哪些缺点? 1、配置成本高昂 虽然一旦系统运行起来,把一块新的服务器刀片插入到刀片服务器很容易,但是在复杂的应用环境下,初始的配置费力又费钱。 2、工具成本高昂 如果你没有往刀片机箱里面塞众多的服务器刀片,也就没有在充分利用刀片机箱。花很多钱购买一只刀片机箱,然后运行里面只有区区几块服务器刀片的整个系统,那没有多大的意义。刀片机箱常常用来容纳14块或16块服务器刀片。 一条普通的经验法则是;如果应用环境需要的服务器数量在5台至10台以下,刀片服务器是不合适的、不划算的。需要5台至10台以下(10至20个处理器)服务器的应用环境最适合使用独立的服务器系统。 3、厂商锁定 厂商之间的刀片系统不一样。一旦你花了50000美元从某一家厂商购买了刀片服务器,由于维修协议,又由于竞争对手不可能拥有与你原来的设备厂商同样的专长,改用另一家厂商的刀片服务器并非总是易事。 从理论上来说,你可以在另一家竞争厂商的刀片机箱里面使用服务器刀片,但是实际上刀片机箱并不是标准化的。IBM刀片系统不可能与戴尔和惠普的刀片系统共享机箱。它们的刀片产品之所以很独特,全在于机箱。服务器刀片常常设计成只能在某家厂商自己的机箱里面运行。 4、商业理由 刀片服务器并不是适合一切应用环境的解决方案。如果你有一个非常大的事务处理应用环境需要很高的读写比,那么可能会在总线速度、内存限制、磁盘访问和网络输入/输出等方面遇到瓶颈。电子邮件和网站服务是刀片计算模式很适合的应用环境。 5、供暖和冷却 一个经常被人所遗忘的缺点是暖通空调(HVAC)。虽然每一台独立的服务器可以分布在整个建筑物的各个地方,可能未必需要放在特殊的配置设施便于冷却,但是如今功能非常强大的刀片服务器每平方英尺就会散发出非常多的热量。要是未加以处理,这么多的热量可能熔化刀片服务器。采购刀片服务器是,牢记这一点很重要:暖通空调方面同样需要额外的资源。 优点: 刀片服务器有哪些优点? 1、结构紧凑、密度高 刀片服务器允许更多的处理能力塞入到更小的空间里,从而简化了布线、存储和维护。刀片服务器经常用于网格计算。刀片服务器的优点不仅仅在于,一个“机柜” 可以放置共享电源及其他组件的多台服务器,还在于可以把存储和网络设备等相关资源合并到比普通服务

统信服务器操作系统产品手册

统信服务器操作系统V20 产品手册

目录 目录............................................................ I 一、基本操作 (1) 1.1登录 (1) 1.1.1图形登录 (1) 1.1.2远程登录 (2) 1.2锁屏 (2) 1.3注销(登出) (4) 1.3.1图形登录方式注销 (4) 1.3.2远程登录注销 (5) 1.4系统关机重启 (5) 1.5启动级别(切换) (6) 1.6分辨率配置 (8) 二、系统管理 (11) 2.1首页介绍 (11) 2.1.1标题栏 (12) 2.2账户设置 (12) 2.2.1创建新帐户 (13) 2.2.2更改头像 (13) 2.2.3修改密码 (14) 2.2.4自动登录 (14) 2.2.5无密码登录 (14) 2.2.6设置指纹密码 (15) 2.2.7删除帐户 (15) 2.3云同步 (15) 2.4显示设置 (16) 2.4.1单屏设置 (17) 2.4.2多屏设置 (18) 2.5默认程序设置 (19) 2.5.1设置默认程序 (20) 2.5.2添加默认程序 (20) 2.5.3删除默认程序 (21) 2.6个性化设置 (21) 2.6.1设置窗口主题 (22) 2.6.2更改活动用色 (22)

2.6.3调节透明度 (23) 2.6.4开启窗口特效 (23) 2.6.5设置图标主题 (23) 2.6.6设置光标主题 (23) 2.6.7更改系统字体 (24) 2.7网络设置 (24) 2.7.1有线网络 (24) 2.7.2无线网络 (25) 2.7.3无线热点 (26) 2.7.4移动网络 (26) 2.7.5拨号网络 (26) 2.7.6VPN (27) 2.7.7系统代理 (27) 2.7.8更改默认程序 (27) 2.7.9应用代理 (28) 2.7.10网络详情 (28) 2.8声音设置 (28) 2.8.1扬声器 (29) 2.8.2麦克风 (29) 2.8.3高级设置 (30) 2.8.4系统音效 (30) 2.9蓝牙设置 (30) 2.9.1修改蓝牙名称 (31) 2.9.2连接蓝牙设备 (31) 2.10日期和时间 (32) 2.10.1修改时区 (32) 2.10.2添加时区 (33) 2.10.3删除时区 (33) 2.10.4修改时间和日期 (33) 2.11电源管理 (33) 2.11.1开启节能模式 (34) 2.11.2唤醒时需要密码 (35) 2.11.3设置显示器关闭时间 (35) 2.11.4设置电脑待机时间 (35) 2.11.5设置自动锁屏时间 (35) 2.12鼠标和触控板 (35) 2.12.1通用设置 (36) 2.12.2鼠标设置 (36)

中科曙光龙腾TC4600L刀片服务器用户手册V1.0

中科曙光TC4600L刀片服务器用户手册

声明 本手册的用途在于帮助您正确地使用曙光公司服务器产品(以下称“本产品”),在安装和第一次使用本产品前,请您务必先仔细阅读随机配送的所有资料,特别是本手册中所提及的注意事项。这会有助于您更好和安全地使用本产品。 请妥善保管本手册,以便日后参阅 本手册的描述并不代表对本产品规格和软.硬件配置的任何说明。有关本产品的实际规格和配置,请查阅相关协议. 装箱单.产品规格配置描述文件,或向产品的销售商咨询。 如您不正确地或未按本手册的指示和要求安装.使用或保管本产品,或让非曙光公司授权的技术人员修理.变更本产品,曙光公司将不对由此导致的损害承担任何责任。 本手册中所提供照片.图形.图表和插图,仅用于解释和说明目的,可能与实际产品有些差别,另外,产品实际规格和配置可能会根据需要不时变更,因此与本手册内容有所不同。请以实际产品为准。 本手册中所提及的非曙光公司网站信息,是为了方便起见而提供,此类网站中的信息不是曙光公司产品资料的一部分,也不是曙光公司服务的一部分,曙光公司对这些网站及信息的准确性和可用性不做任何保证。使用此类网站带来的风险将由您自行承担。 本手册不用于表明曙光公司对其产品和服务做了任何保证,无论是明示的还是默示的,包括(但不限于)本手册中推荐使用产品的适用性.安全性.适销性和适合某特定用途的保证。对本产品及相关服务的保证和保修承诺,应按可适用的协议或产品标准保修服务条款和条件执行。在法律法规的最大允许范围内,曙光公司对于您的使用或不能使用本产品而发生的任何损害(包括,但不限于直接或间接的个人损害.商业利润的损失.业务中断.商业信息的遗失或任何其他损失),不负任何赔偿责任。 对于您在本产品之外使用本产品随机提供的软件,或在本产品上使用非随机软件或经曙光公司认证推荐使用的专用软件之外的其他软件,曙光公司对其可靠性不做任何保证。 曙光公司已经对本手册进行了仔细的校勘和核对,但不能保证本手册完全没有任何错误和疏漏。为更好地提供服务,曙光公司可能会对本手册中描述的产品之软件和硬件及本手册的内容随时进行改进和/或修改,恕不另行通知。如果您在使用过程中发现本产品的实际情况与本手册有不一致之处,或您想得到最新的信息或有任何问题和想法,欢迎致电我们或登录曙光公司服务网站垂询。

奥的斯服务器使用指南

OTIS电梯电脑软件画面 下划线字母可以直接从电脑键盘输入,按键功能与硬件服务器一样。

概述 是利用MECS的模块化控制系统,它由四个模块(或称子系统)构成。分别为:OCSS—OPERA TIONAL CONIROL SUBSYSTEM 操作控制子系统 MCSS—MOTION COMMAND SUBSYSTEM 运行指令子系统 DCSS(DISS)—DOOR CONIROL SUBSYSTEM 门控制子系统 DBSS—DRIVE AND CONIROL SUBSYSTEM 驱动及制动子系统 各子系统之间通过串行通信线(SERIAL LINE)连接来相互交换信息,共同完成电梯的控制功能。服务器使用指南 键盘控制 服务器面板上有16个按键,各按键在面板上的分布如下: 按键功能 MODULE 按此键能进入或返回模块(MODULE)菜单(OCSS,MCSS,DISS,DBSS)FUNCTION 按此键能进入或退出功能(FUNCTION)菜单(MONITOR,TEST,SETUP)SET 按此键能进入或退出设置(SET)菜单 蓝键按此键能启动蓝白双色键的蓝色功能,按此键后,液晶显示屏的第一行的第一个字位上会出现一个闪烁的光标,以示之后必须再按另一个键才能完成某条指令。 0 OFF 表示十进制的“0”无用 1 ON 表示十进制的“1”无用 2 UP 表示十进制的“2” 向上(UP)方向选择键 3 DOWN 表示十进制的“3” 向下(DOWN)方向选择键 4 DISP IN 表示十进制的“4” 表示十六进制的“A” 5 SEL OUT 表示十进制的“5” 表示十六进制的“B” 6 表示十进制的“6” 表示十六进制的“C” 7 DISP STATE 表示十进制的“7” 表示十六进制的“D” 8 ENT CALL 表示十进制的“8”表示十六进制的“E” 9 TEST 表示十进制的“9”表示十六进制的“F” GO ON GO BACK 按此键能看到后一屏的一系列数据(也就是“往下翻一屏”)按此键能看到前一屏的一系列数据(也就是“往前翻一屏”) OTIS模块化电梯

hp刀片功能讲解

HP刀片服务器简单操作讲解
? 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice

Content
刀片系统机箱类型,各部分主件与配件 C7000机箱前视图 C7000机箱后视图 部件安装与规则
C7000系统详解
互连模块与服务器端口映射 刀片系统线缆连接 OA access and setup 故障诊断 操作系统安装 资源访问链接
C3000系统简介
2

c-Class刀片服务器系统—C7000机箱
? 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice

刀片系统机箱类型,各部分主件与配件
机箱类型
4

C-Class刀片服务器有下列主件及配件
电源模块
c-Class刀片机箱
冷却风扇 网络互连模块
5
刀片服务器

c7000 enclosure — Front
? Two blade form factors
? Full-height server blade (up to 8 per enclosure) ? Half-height server blade (up to 16 per enclosure) ? Half-height storage blade (up to 90 drives per enclosure)
HH server blade 2P FH server blade 2P/4P HH storage blade Up to 420GB
? Power supplies
? Up to 6 hot-plug power supplies @ 2250W
? Management
? BladeSystem Insight Display ? Onboard Administrator
Insight Display
6
Hot-plug power supplies