Abdallah et al. - 2009 - Quasi-Unidirectional Radiation Pattern of Monopole Coupled Loop Antenna

Abdallah et al. - 2009 - Quasi-Unidirectional Radiation Pattern of Monopole Coupled Loop Antenna
Abdallah et al. - 2009 - Quasi-Unidirectional Radiation Pattern of Monopole Coupled Loop Antenna

Quasi-Unidirectional Radiation Pattern of Monopole

Coupled Loop Antenna

Mohamed Abdallah,Franck Colombel,Gilles Le Ray,and Mohamed Himdi

Abstract—A monopole coupled loop antenna (MCLA)is studied and modi?ed.The modi?cation includes reducing the size of the antenna and its radiating properties in order to obtain quasi-uni-directional radiation pattern for mobile communications.An anal-ysis of the surface current distribution has been performed to ex-plain this phenomenon.The theoretical results have been validated with measurements.

Index Terms—Inductance loading,loop monopole antenna,quasi-unidirectional radiation patterns.

I.I NTRODUCTION

W

ITH the development of wireless communication ser-vices,such as mobile applications for locating vehicles

or broadcast reception for handy devices,the need for small an-tennas is ever demanding.It is well known that a self-inductor loaded monopole antenna is a suitable solution for reducing the size of the antenna [1],[2].This technique is also applicable to the monopole coupled loop antenna (MCLA)[3].In addition to this,we have to improve the signal reception.Some mobile ap-plications also require to avoid a null in the main direction of the radiation pattern,which in turn provides a quasi-unidirectional pattern.In [4]and [5],three-dimensional (3D)loop antennas provide isotropic and unidirectional radiation patterns,respec-tively.

In ?rst part of this letter,we will consider the theoretical as-pects of self-inductance and investigate its affect on the reso-nant frequency of a MCLA.As per the physical aspects of the antenna,we carefully studied them in order to explain the evolu-tion of the radiation pattern,in the main direction,versus self-in-ductance value.The ?rst part of this study has been carried out using an in?nite ground plane.

In the second part,we present the best size reduction and quasi-unidirectional pattern that we achieved.For a practical case,we propose a modi?ed MCLA on a limited ground plane (300

mm 300mm).The experimental and theoretical results we obtained are in good agreement.

II.MCLA L OADED BY S ELF -I NDUCTANCE

To achieve our ?rst part (decrease the resonant frequency),we modi?ed the MCLA [3]by loading the short circuit of the half-Manuscript received March 17,2009;revised April 22,2009and May 04,2009.First published June 10,2009;current version published July 21,2009.The authors are with the Institute of Electronics and Telecommunications at Rennes,Universitéde Rennes 1,Campus de Beaulieu,35042Rennes,France (e-mail:mohamed.abdallah@univ-rennes1.fr).

Digital Object Identi?er

10.1109/LAWP.2009.2024966

Fig.1.Geometry of the proposed

antenna.

Fig.2.Simulated return loss for the proposed antenna with different values of self-inductance.

loop on the left side with self-inductance (Fig.1).The ground plane is an in?nite

one.

and are respectively the radii of the half-loop and the arc monopole

lines,

and are their

widths.is the angle between the arc monopole extremities.The antenna

has been printed on a Neltec NY9300circuit board

(

,mm).The main dimensions of the antenna are as fol-

lows:

mm,

mm,

mm,

mm,

mm,

mm,.

The inductor component used is an ATC 0805WL modeled with a parallel RLC device.Simulations have been performed with CST Microwave Studio where the equivalent RLC circuit model has been introduced as lumped elements.

In Fig.2,we present the return loss of the loaded MCLA versus frequency for various self-inductance values.The self-inductance values vary from 0nH (equivalent to short circuit)to an in?nite value (equivalent to an open circuit).

In Fig.2,for each inductance,we can notice two resonance frequencies.The ?rst one,linked to the arc monopole,remains constant and very close to 475MHz,whatever may be the self-inductor values.The second one,linked to the half loop radiator associated to the self inductor,decreases from 455to 209MHz.We can also notice that,for these resonances,the antenna be-comes more and more mismatched when the inductance value

1536-1225/$26.00?2009IEEE

Fig.3.Normalized radiation patterns of the short-circuited MCLA at the res-onant frequency (455

MHz).

Fig.4.Schematic of surface currents distribution on radiator elements of short-circuited MCLA at 455MHz.

increases.As mentioned in [3],the antenna return loss at these resonant frequencies could be matched by modifying the length of the arc monopole.

To complete this calculation,we have computed and repre-sented the normalized radiation patterns of the short-circuited MCLA (Fig.3).

For

the

-plane [Fig.3(a)],we obtain a dissymmetric shape of radiation pattern due to the arc monopole in?uence [3].In

the

-plane [Fig.3(b)],the radiation pattern is quasi-omnidirec-tional.It can be noted that the general behavior of the antenna is very close to that of a monopole,except for the dissymmetry

of the radiation pattern in

the

-plane.The schematic surface currents drawn on the radiator ele-ments in Fig.4will fully back up this analysis.

Near the feed point and the short-circuit areas,the surface currents are maximum.It explains that the maximum radiations

are obtained for

the

in

the -plane

when and for

the

in

the -plane

when or 270(Fig.3).In Fig.4,the surface currents become null in

the -direction,which in turn con?rms the deep null of the radiation pattern [Fig.3(a)].Regarding the short-circuited half-loop dimensions,we

noticed

Fig.5.Normalized radiation patterns.(a),(b):MCLA loaded by a 68-nH inductance at 380MHz.(c),(d):MCLA loaded by a 390-nH inductance at 270MHz.(e),(f):Open-circuited MCLA at 210

MHz.

Fig.6.Schematic of surface currents distribution on radiator elements of the MCLA loaded by a 390-nH inductance at 270MHz.

that the operating resonant mode is a half-wavelength one.It explains why there is a current null in the mid-part of the half-loop.

Normalized radiation patterns of the MCLA loaded by 68-nH inductance,390-nH inductance,and in?nite self-inductance (open-circuited)respectively are shown in Fig.5,which com-pletes the results provided in Fig.2.

As depicted in Fig.5,increasing the value of the inductor will

reduce the deep null in the radiation pattern of

the

-plane,

Fig.7.Geometry of the modi?ed open-circuited

MCLA.

Fig.8.(a)Simulated and measured return losses for the modi?ed open-circuit MCLA.(b)Simulated and measured antenna input impedances.(–––)mea-sured,(——)simulated at 450MHz.

which will make the pattern of the antenna a quasi-unidirec-tional in this plane.This phenomenon can be explained with the help of Fig.6,where surface currents represent an inductor value of 390nH.Also in Fig.6,we can notice the change in the position of the current null by comparing it to the null lo-cation in Fig.4.We notice a maximum current located near the short circuit on the right side of the half-loop and a current null located on the left part of the half-loop as seen in Fig.6.We carefully checked the position of this null and noted that it is located at eight-tenths of the total half-loop length starting from the right side (maximum of current).A short calculation shows that this length is close to a quarter-wavelength at 270MHz,and it con?rms the correlation between the maximum and the null location.The inductance modi?es the equivalent antenna’s elec-trical length,and we can deduce the operating wavelength lower than half a wavelength.In the extreme case where the self-induc-tance is in?nite,equivalent to an open circuit,the open-circuited MCLA operating wavelength is worth up to a quarter-wave-

length.

Fig.9.Normalized radiation patterns.(–––)measured,(——)simulated at 450MHz.

In order to complete our analysis we should realize that there

is no signi?cant modi?cation

of

in

the -plane,which re-mains a quasi-unidirectional pattern independent of polariza-tion.

III.M ODIFIED O PEN -C IRCUIT MCLA,T HEORY ,

AND M EASUREMENTS

In this second part,we keep the case of the modi?ed MCLA with an in?nite self-inductance.We call this antenna a modi?ed open-circuit MCLA.As mentioned in the previous paragraph and in [3],we could modify the arc monopole length to enhance the return losses at the resonant frequencies.

Since our interested operating frequency is at 450MHz,we optimized the arc monopole length in order to achieve impedance matching as well as size reduction.Fig.7shows the modi?ed open-circuited MCLA design.For practical reasons,the antenna has set perpendicularly above a limited square ground plane (300

mm 300

mm 4mm).

The main dimensions of the antenna are listed as

follows:

mm,

mm,

mm,

mm,

mm,

mm,.The reduced ratio of

the modi?ed antenna is 55.5%compared to the initial MCLA [1].

Fig.8(a)and (b)show a good agreement between theoretical and measured return losses and input impedance.

Fig.9shows the measured and simulated normalized radia-tion patterns of the modi?ed open-circuit MCLA.

As expected,the radiation pattern is quasi-unidirectional,and there is a good agreement between theory and measurement.At 448MHz,the measured and the theoretical gain are 3.8and 3.9dBi,respectively,and the comparison between them is also good.

https://www.360docs.net/doc/9211100252.html,parative view of antenna dimensions on ground plane.

Despite the reduced dimensions of the modi?ed open-circuit MCLA,compared to the initial one,the gain is higher than that obtained with the earlier MCLA (2.5dBi mentioned in [3]).This difference in gain is due to the difference in the dimension of the ground plane (300

mm 300mm)(Fig.10)

In Fig.10(a),the modi?ed open-circuit MCLA is small com-pared to ground plane and provides radiation pattern with low

back-side radiation

(

dB).In Fig.10(b),the size of the the MCLA from [3]compared to the ground plane is quite equiv-alent,and the back-side radiation is also equivalent to the ra-

diation in the main direction in

the

-plane.This assumption has been veri?ed another time by calculating the theoretical gain with in?nite ground plane for both cases.In the ?rst case (mod-i?ed open-circuit MCLA)and in the second case (MCLA [3]),the directivities are 4and 6.7dBi,respectively,and are propor-tional to antenna dimensions.

IV .C ONCLUSION

While the inductor element is well known to decrease the an-tenna resonant frequency,based on MCLA,a theoretical study has been performed to demonstrate the modi?cation of the radi-ating behavior of MCLA loaded with an inductor.Thus,a mod-i?ed open-circuit MCLA has been proposed.This antenna pro-vides a quasi-unidirectional radiation pattern and allows for a 55.5%reduction in the size of the antenna compared to the ini-tial MCLA [3].The measured gain is high as 3.8dBi.

R EFERENCES

[1]Z.N.Chen and Y.W.M.Chia,“Broadband monopole antenna with

parasitic planar element,”Microw.Opt.Technol.Lett.,vol.27,no.3,pp.209–210,Sep.2000.

[2]C.W.Harrison,“Monopole with inductive loading,”IEEE Trans.An-tennas Propag.,vol.AP-11,no.4,pp.394–400,Jul.1963.

[3]M.Abdallah,F.Colombel,G.L.Ray,and M.Himdi,“Novel printed

monopole coupled loop antenna,”IEEE Antennas Wireless Propag.Lett.,vol.7,pp.221–224,2008.

[4]S.Krishnan,L.-W.Li,and M.-S.Leong,“A V-shaped structure for

improving the directional properties of the loop antenna,”IEEE Trans.Antennas Propag.,vol.53,no.6,pp.2114–2117,Jun.2005.

[5]A.Mehdipour,H.Aliakbarian,and J.Rashed-Mohassel,“A novel elec-trically small spherical wire antenna with almost isotropic radiation pattern,”IEEE Antennas Wireless Propag.Lett.,vol.7,pp.396–399,2008.

板式楼梯计算实例

板式楼梯计算实例 "OU 1OT 用U ----------------------------------------- ------------------------------------- r

58C 11X300=3500 1800 - 240 1------------ :——:——:------------- 7 5800 B2J有承就戕碱板式儀粕桝f 【例题2.1《楼梯、阳台和雨篷设计》37页,PDF版47页】图 2.1为某实验楼楼梯的平面图和剖面图。采用现浇板式楼梯,混凝土强度等级为 C25, f c -11.9N/mm2, f t -1.27N/mm2钢筋直径d> 12mm9寸采用HRB40(级钢筋,f y =360N/mm2; d< 10mrtJ寸采用HPB300级钢筋,f y =270N / mm2,楼梯活荷载为 3.5KN/m2。 楼梯的结构布置如图 2.8所示。斜板两端与平台梁和楼梯梁整 结,平台板一端与平台梁整结,平台板一端与平台梁整结,另一端则与窗过梁整结,平台梁两端都搁置在楼梯间的侧墙上。

580 11X3003300 1800 120 d 1——11 ---------------------------------------------------------- p *--------------------------------- 屮 5800 02.8 试对此现浇板式楼梯进行结构设计。 解: 1)斜板TB1设计 除底层第一跑楼梯的斜板外,其余斜板均相同,而第一跑楼梯斜板的下端为混凝土基础,可按净跨计算。这里只对标准段斜板TB1进行设计。 对斜板TB1取1m宽作为其计算单元。 (1) 确定斜板厚度t 斜板的水平投影净长为I in=3300mm 斜板的斜向净长为 -= ------------ = 3691mm cosa 300 / J150+002

太阳能控制器使用说明书

一、技术参数 工作压力:220V~50Hz 工作环境:-10°~40℃空载功率:4W 温度显示:00℃~99℃测温精度:±2℃ 水位显示:25 50 80 100 漏电动作电流:10mA0.1s 控制增压泵功率:500W 控制电热带功率:500W 控制电加热功率:1500W(可定制3000()w)电磁阀:12V- 工作水压0.02~0.8Mpa (可选装低压阀,工作水压0.01~0.4Mpa) 外形尺寸:1.86×116×42(mm) 二、使用方法 安装完毕,接通电源,控制器开始自检,所有图文符号全亮,并发出蜂鸣提示音,自检结束后显示热水器水箱的水温与水位,如水位低于25,水温≤95℃,自动上水至设置水位。控制器按照出厂设定的参数自动运行。控制器五种模式:智能模式、定时模式、恒温模式、恒水位模式、温控模式。 1、智能模式(出厂设置模式) 4:00启动上水至50水位,5:0C启动加热至50℃,保证早晨起床后的洗漱用水:9:00上水至1 00水位,16:00启动加热至60℃,保证晚上有60℃的水供用户使用;若15:00低于80水位,则再补水至80水位。 2、定时模式 若智能模式不能满足您的需求,持续按“上水”键3秒钟启动定时上水模式,持续按“加热”键3秒钟启动定时加热模式,只能模式关闭。 定时模式出厂参数如下: 第一次定时上水时间为“09:00”,第二次、第三次定时上水时间设置为“一一”。三次上水

设置水位均为“100水位”。“一一”代表该功能未启动(下同)。 第一次定时加热启动时间为16:00,第二次、第三次定时加热启动时间设置为“一一”。 三次定时加热终止温度均为“60℃”。 如果定时模式出厂参数不能满足您的需求,您可以根据您的需求一次作如下设置,设置期间如10秒钟没有按键动作则自动退出,所修改的容自动保存。 2-1定时上水时间和水位设置 持续按“上水”键3秒钟,“定时上水”亮,此时智能模式关闭,蜂鸣提示一声。 2.1.1第一次定时上水时间和水位设置:屏幕显示“定时上水、F1”亮,“09”闪烁(09:F1表示第一次定时上水时间为9:00)。然后按V键在00:00-23:00、一一围设置第一次定时上水时间。继续按“SET”键,此时“定时上水、XX:F1”亮,“水位”闪烁,按V键在50-100围设置第一次定时上水停水水位。 2.1.2第二次定时上水时间和水位设置:继续按SET键,此时“定时上水、F2”亮,“一一”闪烁。然后按SET键,此时定时上水、xx:F2亮,水位闪烁,按V键在50-100围设置第二次定时上水停水水位。 2.1.3第三次定时上水时间和水位设置:继续按SET键,此时“定时上水、F2”亮,“一一”闪烁。然后按SET键,此时定时上水、xx:F2亮,水位闪烁,按V键在50-100围设置第三次定时上水停水水位。 2.2定时加热启动时间和加热终止温度设置 持续按“加热”键3秒,“定时加热”亮,此时智能模式关闭,蜂鸣提示一声。 2.2.1第一次定时加热启动时间和加热终止温度设置:屏幕显示定时加热、F1亮,1.6闪烁(16:F1表示第一次定时加热时间为16:00).然后按V键在00:00-23:00、一一围设置第一次定时加热时间。继续按SET键,此时定时加热、XX:F1亮。60℃闪烁,按V键在40℃-60℃围

板式楼梯设计典型例题

3.4.5 楼梯设计例题 设计资料 ?某公共建筑标准层层高为3.6m,采用现浇板式楼梯,其平面布置见图3.53。

?楼梯活荷载标准值为q =2.5KN/m2,踏 k 步面层采用30mm厚水磨石面层(自重为0.65 KN/m2),底面为20mm 厚混合砂浆(自重为17 KN/m3)抹灰。 ?采用C25混凝土,梁纵筋采用HRB335级钢筋,其余钢筋均采用HPB235级钢筋。 梯段板设计 估算斜板厚h=lo/30=3500/30=117(mm),取=120mm。 板倾斜角为tanα=150/300=0.5 (由踏步倾斜得来)

取1m 宽板带进行计算。 (1)荷载计算 恒荷载标准值 水磨石面层: (0.3+0.15)×0.65×3.01 =0.98(KN/m) 三角形踏步: 2 1×0.3×0.15×25×3.01 =1.88(KN/m) 混凝土斜板: 0.12×25×1/0.894=3.36(KN/m) 板底抹灰: 0.02×17×1/0.894=0.38(KN/m) 恒荷载标准值 g k =6.60 KN/m 恒荷载设计值g =1.2×6.60=7.92 KN/m 活荷载设计值q =1.4×2.5=3.5 KN/m 合计 p =g+q =11.42 KN/m (2)截面设计 水平投影计算跨度为 lo=ln+b =3.3+0.2=3.5m

弯矩设计值 2 0)(101l q g M +==25.342.1110 1?? =13.99(KN ·m) 斜板有效高度: ho=120-20=100(mm) 2 01bh f M c s αα= =26 10010009.110.110 99.13???? =0.188, 937.0=s γ 0h f M A s y s γ= =100937.02101099.136 ???=711(mm 2) 选配φ10@110,As=714mm 2 ,梯段板的配筋见图3.54。 配筋要求见P89。 ?受力钢筋:沿斜向布置。 ?构造负筋:在支座处板的上部设置一定数量,以承受实际存在的负弯矩和防止产生过宽的裂缝。一般取φ8@200,长度为l n /4。 本题取φ8@200,3300/4=825mm ,取850mm 。 ?分布钢筋:在垂直于受力钢筋方向按构造配置,每个踏步板内至少放置一根分布钢筋。放置在受力钢筋

板式和梁式楼梯手算及实例

1. 板式楼梯 例8-1 某公共建筑现浇板式楼梯,楼梯结构平面布置见图(8-6)。层高3.6m ,踏步尺寸150× 300mm 。采用混凝土强度等级C25,钢筋为HPB235 和 HRB335。楼梯上均布活荷载标准值=3.5kN /m 2,试设计此楼梯。 1. 楼梯板计算 板倾斜度 ,5.000150==αtg 894.0cos =α 设板厚h=120mm ;约为板斜长的1/30。 取lm 宽板带计算 (1) 荷载计算 图8-6 例8-1的楼梯结构平面 荷载分项系数 2.1=G γ 4.1=Q γ 基本组合的总荷载设计值 m kN p /82.124.15.32.16.6=?+?= 表8-1 梯段板的荷载 (2) 截面设计

板水平计算跨度m l n 3.3= 弯矩设计值 m kN pl M n ?=??== 96.133.382.1210110122 mm h 100201200=-= 117.010010009.111096.132 62 01=???== bh f M c s αα 614.0124.0117.0211211=<=?--=--=b s ξαξ 2 01703210124 .010010009.11mm f bh f A y c s =???= = ξ α %27.021027 .145.045.0%59.01201000703min 1===>=?== y t s f f bh A ρρ 选配?10@110mm, A s =714mm 2 分布筋?8,每级踏步下一根,梯段板配筋见图(8-7)。 表8-2 平台板的荷载 2. 平台板计算 设平台板厚h=70mm, 取lm 宽板带计算。 (1) 荷载计算 总荷载设计值 m kN p /19.85.34.174.22.1=?+?= (2) 截面设计 板的计算跨度 m l 76.12/12.02/2.08.10=+-= 弯矩设计值 mm h 5020700=-= m kN pl M ? = ? ? = = 54 . 2 76 . 1 19 . 8 10 1 10 1 2 2 0

梁式和板式楼梯设计

《混凝土结构设计原理》实验报告 实验三楼梯设计 土木工程专业10 级 3 班 姓名 学号 指导老师 二零一三年一月 仲恺农业工程学院城市建设学院

目录 一、主体介绍 (4) 二、现浇板式楼梯设计 (5) 1. 梯段板TB2设计 (5) 1) 荷载计算 (5) 2) 截面设计 (6) 2. 平台板PTB2设计 (6) 1)荷载计算 (7) 2)截面设计 (7) 3. 平台梁TL4设计 (8) 1)荷载计算 (8) 2)截面设计 (9) 3)斜截面受剪承载力计算 (9) 4)配筋图 (10) 4. 平台梁TL5设计 (10) 1)荷载计算 (10) 2)截面设计 (10) 3)斜截面受剪承载力计算 (12) 4) 配筋图 (12) 5.构造柱GZ设计 (12) 三、现浇梁式楼梯设计 (13)

1.踏步板设计 (13) 1)荷载计算 (13) 2)截面设计 (14) 3) 配筋图 (14) 2.斜梁TL2设计 (15) 1)荷载计算 (15) 2)截面设计 (15) 3)斜截面受剪承载力计算 (16) 4)构造钢筋 (17) 3.平台板PTB1设计 (17) 1)荷载计算 (17) 2)截面设计 (18) 4.平台梁TL3设计 (18) 1)荷载计算 (19) 2)截面设计 (19) 3)斜截面受剪承载力计算 (21) 5.梯梁TL1设计 (21) 1)荷载计算 (21) 2)截面设计 (22) 3)斜截面受剪承载力计算 (23) 四. 总结 (24)

仲恺农业工程学院实验报告纸 城市建设学院(院、系) 土木工程 专业103 班 组 混凝土结构设计原理 课学号: 姓名: 实验日期:2012/12/23 教师评定: 实验三 楼梯设计 一、主体介绍 1. 广州市某商住楼楼梯结构设计,采用现浇整体式钢筋混凝土板式楼梯或梁式楼梯。混凝 土采用C25级,梁中的纵向受力钢筋采用HRB335,板及其他钢筋采用HPB300。楼梯间活荷载标准值为2 /5.2m KN q =。 2. 主体结构类型:框架结构 3. 建筑资料:楼面做法(自上而下) 10mm 厚耐磨地砖(3/22m KN =γ); 1:3水泥砂浆找平20mm 厚(3 /20m KN =γ) 现浇钢筋混凝土楼板(3 /25m KN =γ); 板底混合砂浆抹灰20mm 厚(3 /17m KN =γ); 混凝土采用25C (c f =11.9N/mm 2,t f =1.27N/mm 2),板的保护层厚度20mm ,梁的保护层厚度为25mm ;

太阳能热水器控制仪使用说明书资料

太阳能热水器控制仪使用说明书 太阳能热水器使用说明,一般情况下也就是说的太阳能热水器控制仪的使用方法,在这里我们拿最常用的西子控制仪说明书,为大家讲解一下使用方法,希望对大家在使用过程中减少一些疑难问题,方便大家使用。 TMC至尊全天候测控仪使用说明书 【主要技术指标】 1.使用电源:220VAC功耗:<5W 2.测温精度:±2℃ 3.测温范围:0-99℃ 4.控温精度:±2℃ 5.水位分档:五档环形显示 6.可控水泵或电热带功率:≤500W 7.可控电加热功率:≤1500W可选:3000W 8.漏电动作电流:≤10mA/0.1s 9.电磁阀参数:直流DC12V,可选用有压阀或无压阀 有压阀工作压力:0.02MPa~0.8MPa 无压阀工作压力:0.0MPa,适用于水箱供水或低压供水 10.广域亮彩显示屏低功耗:<0.5W 【主要功能】 1.北京时间:实时显示北京时间 2.水位预置:可预置加水水位50、80、100% 3.水温预置:可预置加热温度范围:30℃-80℃,定时加热若不需要启动电加热,可预

置为00℃ 4.水温指示:显示太阳能热水器内部实际水温 5.水位指示:显示太阳能热水器内部所存水量 6.缺水提示:当水位从高变低,出现缺水状态时,蜂鸣报警,同时20%水位闪烁 7.缺水上水:当水位从高变低,出现缺水状态时,延时30分钟自动上水至预置水位 8.手动控制:可手动启动上水、加热,在操作时首先显示预置的水位或水温,用户可利用▲、▼键调整预置参数,确认后,启动上水、加热,也可手动关闭。启动加热时水位若低于50%,则先启动上水再加热。正在加热时水位低于50%自动关闭加热,保护电加热管。启动手动上水时,若实际水位大于等于预置水位时,测控仪自动上调预置水位,以保证用户上水需求,启动手动加热时,若实际水温大于等于预置水温时,自动上调预置水温,以保证用户加热需求,建议用户预置水温不超过60℃ 9.自选模式:有智能、定时、温控三种模式可选 定时模式:可设定二次定时上水、二次定时加热,原厂设置定时上水第一次9:00上水至100%水位,第二次15:00启动上水至100%水位。定时加热,第一次4:00加热至50℃,第二次16:00加热至50℃。用户可重新设定时间及参数,完全满足用户个性化需求. 温控模式:当水箱水未加满,水温高于用户设定的温控上水温度(原厂设置为60℃)自动补水至低于温控温度10℃的合适水温,此功能可防止出现低水量、高水温的不合理现象。当正在用水(水位发生变化)时,则延时60分钟启动,以避免用户正在用水时启动上水。几倍温控功能的时间:8:00-17:00。此模式下不自动启动电加热,用户根据需要可选择手动加热,此模式最为节能。 智能模式:3:00启动上水至50%水位,4:00加热至50℃,保证用户早晨起床后的洗漱用水,9:00上水至100%水位,若中途用户有用水,水位低于80%水位,则测控

板式楼梯计算实例

板式楼梯计算实例

【例题 2.1《楼梯、阳台和雨篷设计》37页,PDF 版47页】 图2.1为某实验楼楼梯的平面图和剖面图。采用现浇板式楼梯,混凝土强度等级为C25,2211.9/, 1.27/c t f N mm f N mm ==钢筋直径d ≥12mm 时采用HRB400级钢筋,2360/y f N mm =;d ≤10mm 时采用HPB300级钢筋, 2270/y f N mm =,楼梯活荷载为3.5KN/m 2。 楼梯的结构布置如图2.8所示。斜板两端与平台梁和楼梯梁整结,平台板一端与平台梁整结,平台板一端与平台梁整结,另一端则与窗过梁整结,平台梁两端都搁置在楼梯间的侧墙上。

试对此现浇板式楼梯进行结构设计。 解: 1)斜板TB1设计 除底层第一跑楼梯的斜板外,其余斜板均相同,而第一跑楼梯斜板的下端为混凝土基础,可按净跨计算。这里只对标准段斜板TB1进行设计。 对斜板TB1取1m宽作为其计算单元。 (1)确定斜板厚度t 斜板的水平投影净长为l1n=3300mm

斜板的斜向净长为113691cos n n l l mm α= == 斜板厚度为t 1=(1/25~1/30)l 1n =(1/25~1/30)×3300=110~120mm,取t 1=120mm 。(根据“混凝土结构构造手册(第四版)”384页) (2)荷载计算,楼梯斜板荷载计算见表2.3。 表2.3楼梯斜板荷载计算 水磨石面层的容重为0.65KN/m 2(GB50009-2012,附录A-15,84页);纸筋灰容重16KN/m 3(GB50009-2012,附录A-6,75页,实际工程中已被水泥砂浆代替)以上计算的荷载设计值是由可变荷载控制的组合,计算由永久荷载控制的组合 1.357.160.98 3.513.10/p KN m =?+?=,综合取p=13.50KN/m (3)计算简图 如前所述,斜板的计算简图可用一根假想的跨度为l 1n 的水平梁

板式楼梯设计及实例

板式楼梯设计及实例 ——摘自2013版《毕业设计指导书》 3. 4 楼梯设计 钢筋混凝土楼梯按楼梯段结构形式可分为板式、梁式、剪刀式、螺旋式和有中柱的盘旋式等。选择楼梯的结构形式,应根据楼梯的使用要求、材料供应、施工条件等因素,本着适用、经济、适当照顾美观的原则确定。板式楼梯具有楼梯下表面平整、施工方便、外观轻巧等优点。当梯段板水平方向跨度小于3.3m ,活荷载不大时,宜采用板式楼梯。 3. 4. 1 现浇板式楼梯 现浇板式楼梯由梯段板、平台板和平台梁组成。可分为斜板式和折线形板式两种。斜板式楼梯跨度较小,经济、构造简单,应优先采用;当建筑上有要求,不便于设置支承平台梁的小柱时,也可以做成折线形板式楼梯,其跨度为斜梯段及平梯段之和。 一、 梯段板 斜板式楼梯的梯段板是一块支承在上、下平台梁上并带有踏步的斜板,如图3-4a 所示。梯段板的厚度一般取L h )301~251(=,L 为支承梁中心投影的水平距离,当荷载较大时,h 应选用较大值。作用于梯段板上的活荷载是沿水平方向分布的,因此斜板的恒荷载一般也换算 成水平方向上的均布荷载,计算简图如图3-4c 所示。考虑到平台梁、平台板对斜板的弹性约束作用,可使斜板跨中弯矩减小,因而斜板跨中最大弯矩和支座最大剪力可取: 2max )(10 1o l q g M += (3-6) θcos )(2 1max n l q g V += (3-7) 图3-4 斜板式梯段板及计算简图

式中: q g 、——梯段板沿水平方向上的恒荷载 和活荷载设计值; n l l 、0——梯段板的计算跨度及净 跨度的水平投影长度;θ ——梯段板的倾角。 斜梯板一般采用分离式配筋,截面计算高度应取 垂直于斜板的最小高度。一般用HPB300级钢筋,也 可选用HRB400钢筋。考虑到斜板与平台梁、板的整 体性,斜板两端支座的负钢筋用量可取跨中截面配筋 的1/2,负筋长度应伸入跨内不少于1/4板净跨度。在 垂直于受力钢筋方向按构造设置分布钢筋,每个踏步 下放置1φ8。 折线形板式楼梯由带有踏步的斜梯段和平梯段组 成,如图3-5所示。斜梯段和平梯段的板厚相等,可 取L h )30 1~251(=,L 为斜梯段和平梯段的总投影长度。受力计算也是将斜梯段上的荷载化成沿水平方向 分布的荷载,和平梯段一起组成水平方向的简支板,然后用静力学的方法,求出跨中最大弯矩及支座剪力。 折线形板式楼梯在上、下端弯折处的配筋相同但构造不同。在上端弯折处,为避免受拉钢筋产生向外的合力使混凝土保护层剥落,或者钢筋被拉出,应将纵向钢筋断开并分别予以锚固,锚固长度不少于La ,此时梯板的负筋长度应从支座算起不少于1/3总跨度。在下端弯折处,则受拉钢筋不断开而连续配置。 楼梯扶手计算:可在扶手下的梯板内另加2φ12钢筋以专门承受扶手荷载,在梯段板计算中不再考虑扶手重。但在计算平台梁时,扶手荷载则应考虑。 楼梯的混凝土强度等级宜与各层楼盖的强度等级相同,以方便施工。 梯板的跨高比一般较大,不必作斜截面受剪承载力验算,且梯板不超过不需作挠度验算的最大跨高比时,也不必作变形和裂缝验算。 二、 楼梯梁 楼梯梁可按简支的倒L 形梁计算。作用于梁上的荷载除梁自重和梯段板、平台板传来的均布荷载外,还有梯扶手传来的集中力。梁截面高度应不小于跨度的1/12。 位于层间的楼梯梁,除在两端有框架柱或剪力墙支承的情况外,也可以在下层楼盖梁用梁上柱或在上层楼盖梁用吊柱的方法支承。 图3-5 折线形板式楼梯

太阳能热水器微电脑全智能测控仪使用说明

太阳能热水器微电脑全智能测控仪使用说明现在目前大多数太阳能微电脑的功能与操作如下:(说明:为了用户跟好使用,本人义务为大家扫描微电脑说明书,有可能个别字乱码错误,见谅) 特点:上水实现全自动,有恒温补水功能,定时上水,水温水位数码彩屏显示,采用人性化设计,具有水位预置、低水压上水模式、可定时控制,手动控制、自动防溢流、高温保护等主要功能,使用更方便、更安全、更实用。 一、主要技术指标 1、使用电源:220VAC功耗:<5W 2、测温精度:土2C 3、测温范围:0-99 %C 4、水位分档:五档 5 、电磁阀参数:直流DCI 2V,可选用有压阀或无压阀 二、主要功能 1、开机自检:开机时发出“嘀”提示音,表示机器处于正常状态 2、水位预置:可预置加水水位50、80、100% 3、水位显示:显示太阳能热水器内部所有水量 4、水温显示:可显示太阳能热水器内部实际水温 5、水温预置:可预置加热温度 3 0%-80 %,若不需要加热功能,可预置为00 C。 6、缺水报警:当水位从高变低,出现缺水状态时,蜂呜报警,同时位时,测控仪会自动进入低水压模式,“低水压” 图案点亮,在此上水模

式中,测控仪会间隔30 分钟启动一次,同时测控仪自动静音,以免上水、关闭时经常蜂呜,打扰用户休息:按“上水键”可取消该次低水压上水模式: 11 、温控上水:当水箱水未加满,水温以超过85~C 时,自动补水至合适水温65cC 左右,此功能可防止出现低水量高水温的不合理现象。 12 、定时上水:若有供水不正常,有时有水,有时没水等特殊情况用户可根据自己的生活习惯,设定定时上水或定时加热,设定完毕后测控仪每天会根据所设定的时间自动上水及加热。 1 3、强制上水:水位传感器出现故障时,可按“上水”键,实现强制止水,每分钟会出现蜂鸣提示,注意有无溢水,8 分钟后自动关闭上水。 三、使用方法 通电后,测控仪会自动将水位加满至100%,如果无太阳光照使 水温升高,则3小时后自动加热至水温50C,太阳能上水、加热是合智能运行的,因此,用户不必作任何操作,若想变更预置水位、水温或采用定时模式,可按如下方法操作: 1 、水温水位设置:先按“预置”键,当前预置温度。预置水位快速跳动,然后按“上水、水位”键设置水位,按“加热、水温”键设置水温,请用户根据自己的需要设置到所需水位和水温;建议设置水温不超过60?C,可充分利用太阳能,减少电加热,节约电能。2、定时控制:在需要定时上水或加热时,长按“上水、水位”键或“加热、水温”键盘,约 3 秒钟听到“嘀”短提示音后放手,数码显示“ 00'', 然后按“上水、水位”或“加热、水温”键调整时间,设定温度C或圆圈图案闪烁:若3小时后上水或加热,先按“上水、水位”键或“加热、保温” 键盘约3 秒钟,听到“嘀” 短提示音后放手,再按“上水、水位”

现浇板式楼梯设计实例

板式楼梯设计 一、板式楼梯 板式楼梯是指梯段板为板式结构的楼梯。板式楼梯由梯段板、平台板和平台梁组成,如图 2.43所示。板式楼梯荷载传递路线为:梯段板T平台梁T墙(柱)。板式楼梯的梯段板为带有踏步的斜板,两端支承 在平台梁上。平台板一端支承在平台梁上,另一端支承在楼梯间的墙(或梁)上,平台梁两端支承在楼梯间的墙(或梁、柱)上。板式楼梯梯段板底面平整,外形轻巧、美观,施工方便,但当梯段跨度较大时,斜板较厚,材料用量较多,所以一般用于梯段跨度不太大的情况(一般在3m以内)。 图2.43 板式楼梯的组成 1■梯段板 h= (1/25?1/30 )|。(|。为梯段板的计算跨度),常用厚度为100?120m m。梯段板是一块带有踏步的斜板, 可近似认为简支于上、下平台梁上,梯段板的计算跨 度可取其净跨,其计算简图如图 2.44所示。 由结构力学可知,斜置简支构件的跨中弯矩可按平置构件计算,跨长取斜构件的水平投影长度,故梯段斜板可简化为两端简支的水平板计算。由于板的两端与平台梁为整体连接,考虑梁对板的约束作用,板 (1 )梯段板内力计算梯段板的厚度一般取 ffunn 图2.44 梯段板的计算简图 mTmnTrrnrn |o= g+q

的跨中弯矩相对于简支构件有所减少,故跨中最大弯矩一般可按 作用在梯段板上的沿水平方向单位长度上的恒荷载、活荷载设计值; l o =ln ,l n 为梯段板净跨的水平投影长度。 为了满足建筑使用要求,有时采用折线形梯段板,折线形梯段板的梯段荷载和平台荷载有所差别,但 差别不大。为了简化计算,可近似取梯段荷载和平台荷载中的较大值来计算跨中弯矩,从而计算出梯段配 筋。折线形梯段板的荷载及计算简图见图 2.45。 图2.45 折线形梯段板的荷载 (2 )梯段板钢筋配置 梯段斜板中的受力钢筋按跨中最大弯矩计算求得,并沿跨度方向布置。为考 虑支座连接处实际存在的负弯矩, 防止混凝土开裂,在支座处板面应配置适量负筋, 一般不小于 ①8@200, 其伸出支座长度为l n /4 ( l n 为梯段板水平方向净跨度)。在垂直受力钢筋的方向应设置分布钢筋,分布钢筋 应位于受力筋的内侧,并要求每踏步内至少 1①&梯段板钢筋布置见图 2.46。 折线形梯段板曲折处形成内折角,若钢筋沿内折角连续配置,则此处受拉钢筋将产生较大的向外的合 力,可能使该处混凝土保护层剥落,钢筋被拉出而失去作用。因此,在折线形梯段的内折角处,受力钢筋 1 2 M max (g q )l o 计算,其中g 、q 为 10 l

太阳能热水器微电脑全智能测控仪使用说明[终稿]

太阳能热水器微电脑全智能测控仪使用说明[终稿] 太阳能热水器微电脑全智能测控仪使用说明 现在目前大多数太阳能微电脑的功能与操作如下:(说明:为了用户跟好使用,本人义务为大家扫描微电脑说明书,有可能个别字乱码错误,见谅) 特点:上水实现全自动,有恒温补水功能,定时上水,水温水位数码彩屏显示,采用人性化设计,具有水位预置、低水压上水模式、可定时控制,手动控制、自动防溢流、高温保护等主要功能,使用更方便、更安全、更实用。 一、主要技术指标 1、使用电源:220VAC功耗:<5W 2、测温精度:?2? 3、测温范围:0-99,? 4、水位分档:五档 5、电磁阀参数:直流DCl 2V,可选用有压阀或无压阀 二、主要功能 1、开机自检:开机时发出“嘀”提示音,表示机器处于正常状态 2、水位预置:可预置加水水位50、80、100, 3、水位显示:显示太阳能热水器内部所有水量 4、水温显示:可显示太阳能热水器内部实际水温 5、水温预置:可预置加热温度30,-80,,若不需要加热功能,可预置为00?。 6、缺水报警: 当水位从高变低,出现缺水状态时,蜂呜报警,同时位时,测控仪会自动进入低水压模式,“低水压”图案点亮,在此上水模式中,测控仪会间隔30分钟启动一次,同时测控仪自动静音,以免上水、关闭时经常蜂呜,打扰用户休息:按“上水键”可取消该次低水压上水模式:

11、温控上水: 当水箱水未加满,水温以超过85~C时,自动补水至合适水温65cC左右,此功能可防止出现低水量高水温的不合理现象。 12、定时上水:若有供水不正常,有时有水,有时没水等特殊情况用户可根据自己的生活习惯,设定定时上水或定时加热,设定完毕后测控仪每天会根据所设定的时间自动上水及加热。 1 3、强制上水:水位传感器出现故障时,可按“上水”键,实现强制止水,每分钟会出现蜂鸣提示,注意有无溢水,8分钟后自动关闭上水。 三、使用方法 通电后,测控仪会自动将水位加满至100,,如果无太阳光照使水温升高,则3小时后自动加热至水温50?,太阳能上水、加热是合智能运行的,因此,用户不必作任何操作,若想变更预置水位、水温或采用定时模式,可按如下方法操作: 1、水温水位设置:先按“预置”键,当前预置温度。预置水位快速跳动,然后按“上水、水位”键设置水位,按“加热、水温”键设置水温,请用户根据自己的需要设置到所需水位和水温;建议设置水温不超过60~C,可充分利用太阳能,减少电加热,节约电能。 2、定时控制:在需要定时上水或加热时,长按“上水、水位”键或“加热、水温”键盘,约3秒钟听到“嘀”短提示音后放手,数码显示“00'’,然后按“上水、水位”或“加热、水温”键调整时间,设定温度?或圆圈图案闪烁:若3小时后上水或加热,先按“上水、水位”键或“加热、保温”键盘约3秒钟,听到“嘀”短提示音后放手,再按“上水、水位”或“加热、水温”键三下,数码显示“03”则定时完成,三小时后启动上水或加热功能(以后第天该时启动止水或加热。 3、温控上水:根据季节不同,太阳光照不同,可设置温控上水功能,按“电源”键温控上水则启动,若取消再按电源键同取消。

钢筋混凝土板式楼梯设计楼梯板及平台板配筋图

钢筋混凝土板式楼梯设计 楼梯板及平台板配筋图 Revised by Liu Jing on January 12, 2021

六、钢筋混凝土板式楼梯设计 楼梯设计包括建筑设计和结构设计两部分。 一、设计资料 建筑设计 1、楼梯间建筑平面,开间:3300mm。进深:4800mm。 5楼梯形式尺寸:双跑楼梯,层高4600mm,踏步采用180mm×270mm,每层共需4600/180=25步。如图建筑图中所示。 二、结构设计采用板式楼梯 1、楼梯梯段板计算: 混凝土采用C20,单d≤10mm时,采用Ⅰ级钢筋;单d≥12mm时,采用Ⅱ级钢筋,fc=9.6kN/mm2,fy=210 kN/mm2 2假定板厚:h=l/30=2700/30=90mm,取h=100mm。 3荷载计算(取1米板宽计算) 楼梯斜板倾角: a=tg-1(180/270)=26.530 cosa=0.895 恒载计算: 踏步重(1.0/0.3)×0.5×0.15×0.3×25=1.875 kN/m 斜板重(1.0/0.895)×0.1×25=2.8kN/m 20mm厚面层粉刷层重: [(0.3+0.15)/0.3]×0.02×20×1.0=0.6kN/m 15mm厚板底抹灰: (1.0/0.895)×0.015×17=0.32kN/m

恒载标准值 gk=1.875+2.8+0.60+0.29=5.57 kN/m 恒载设计值 gd=1.2×5.57=6.68 kN/m 活载计算: 活载标准值 Pk=2.5×1.0=2.5 kN/m 活载设计值 Pd=1.4×2.5=3.5 kN/m 总荷载设计值 qd=gd+pd=6.68+3.5=10.18kN/m (3)内力计算 跨中弯矩:M=qdl2/10=10.18×2.72/10=7.42 kN.m (4)配筋计算(结构重要系数r =1.0) h0= h-20=100-20=80mm ɑs=r 0M/(fcbh 2)=1.0×7.42×106/(9.6×1000×802)=0.12 ξ=1-(1-2ɑs)0.5=0.1282 As= fcbh ξ/fy=9.6×1000×0.1282×80/210=468.85mm2 受力钢筋选用10@150(As=604 mm2) 分布钢筋选用6@300 2、平台板计算 (1)荷载计算(取1米板宽计算) 假定板厚80mm,平台梁TL-1截面尺寸200×300mm,TL-2截面尺寸为150×300mm。 楼梯板及平台板配筋图 恒载:平台板自重 0.08×1.0×25=2 kN/m 20mm厚抹面: 0.02×1.0×20=0.4kN/m

力诺瑞特 阳光智宝 III型 测控仪操作指导书(LPZC-C03仪表操作说明书)

阳光智宝Ⅲ型(LPZC-C03)测控仪操作指导书 一、技术参数 工作电压: 220V 50Hz 工作环境: -10℃~40℃ 95%RH 空载消耗功率:≤4W 温显范围: 0~99℃ 测温精度: ±2℃ 水位显示: 25 50 75 100 电磁阀:12VAC 工作压力0.02Mpa~0.8Mpa 控制电加热功率:≤1500W (可选用2000W电加热,但同时开启伴热带时要注意电负荷!) 控制增压泵(循环泵)功率:≤500W 控制伴热带功率:≤500W 二、操作方法 1、开机自检 接通电源后仪表开始自检,所有指示符号全亮,并发出提示音,自检结束后显示水温与水位,如水位低于25,水温≤95℃,测控仪自动上水至100。

出厂设置参数: F1时段:定时上水设置为3:00,上水水位设置为50(可在50~100之间设置);定时加热设置为4:00,温度设置为50℃(可在40~80℃之间 设置)。 F2时段:定时上水设置为11:00,上水水位设置为100(可在50~100之间设置);定时加热设置为16:00,温度设置为60℃(可在40~80℃ 之间设置),其余功能全自动运行。 多功能输出端口:管道保温。 2、个性化设置: 北京时间调整: 在水温水位显示状态下,按住“△”键约3秒钟,听到“嘀”声后,按“△”键可调整小时,按住“▽”键约3秒钟,听到“嘀”声后,按“▽”键可调整分钟。 3、常规设置: 设置第一时段整点定时上水时间: 依次按“SET”键约3秒钟,听到“嘀”声后,“F1、上水”亮,“时间”

指示闪动,按“△”或“▽”键设置整点定时上水时间。 设置第一时段整点定时上水水位: 依次按“SET”键,“F1、上水”亮,“水位”指示闪动,按“△”或“▽”键设置50~100停水水位。 设置第一时段整点定时加热时间: 依次按“SET”键,“F1、加热”亮,“时间”指示闪动,按“△”或“▽”键设置整点定时加热时间。 设置第一时段整点定时加热温度: 依次按“SET”键,“F1、加热”亮,“温度”指示闪动,按“△”或“▽”键,可在40℃~80℃范围内设置F1时段电辅助加热温度。

DCB-9418压力液位测控仪使用说明书

DCB-9418压力、液位测控仪是我公司科技人员在解剖、分析、研究、总结了国内外先进压力、液位测控仪的基础上,结合我国工业现场的环境、操作人员的习惯等实际情况,利用军工技术,采用国际上最优秀的集成芯片,开发出的一个高性能价格比的产品。已广泛的应用于冶金、石油、化工、电力、水利、城市防洪、生活供水等行业。 欢迎使用DCB-9418压力、液位测控仪,愿它给您带来更佳的经济、社会效益。 ★DCB-9418普通型接收标准为: 4~20mA,如需要改动请在合同中注明特殊的工艺、性能、技术要求。 ※应用举例N O.1(江、河、水库、湖泊、容器等液位的测量) ※H1—“基点”设定值,即变送器安装的位置距离液位底部的高度或者变送器安装的海拔高度; ※H2—下限报警高度; ※H3—上限报警高度; ※RS232C输出用于远距离给计算机网络提供资料或者用于远距离多点显示液位的高度; https://www.360docs.net/doc/9211100252.html, 1

※4~20mA 输出主要用于近距离给计算机网络提供信号;※应用举例N O.2(恒压供气测量、控制系统) ※应用举例N O.3(水塔自动上水、楼寓恒压供水系统) 2

※应用举例N O.4密封罐内液位的测量 ※应用举例N O.5水厂拦污栅前、后水位差的测量、控制系统 https://www.360docs.net/doc/9211100252.html, 3

※应用举例N O.6水坝、防洪水位多点观测系统 H1——变送器安装的海拔高度; H2——下限报警高度; H3——上限报警高度; *一台DCB-9418测控仪可以为三台DCB-9418测控仪提供 显示控制、信号,第二级显示仪表又可以为第三级仪表提供显示控制、信号; *数据最大传输距离为:8km; *使用时只需要调整最前端的一台DCB-9418测控仪即可; *如果在野外安装,变送器应选择防雷击型变送器; 1. 特点: →不用打开机箱就可完成全部调校; →适合所有标准输出的变送器(加接口可适用传感器); →特别适用于测控工业现场的压力、液位、差压; →微处理操作,全数字式调校; →显示选用清晰、稳定、超高亮度的七段数码管; →最大显示值可达99999; →小数点有四个位置可供选择; 4

板式楼梯配筋计算实例.

9 板式楼梯设计 9.1 楼梯建筑设计 (1)楼梯甲(净面积3350×7150)、楼梯乙(净面积3325×7150)、楼梯丙(净面积3350×7150)计算(梯段宽取1600mm ): 设h =150mm ,N=1503900 =26, 2h +b =600~620mm 且h +b ≈450mm ,取b =300mm 。 平台宽度≥900+300=1200,取1700mm 。 第一梯段:7150-1700-900=4550mm 4550/300=15.2,取15步。 平台实际长度=300×15=4500mm 首层平台高度=150×16=2400mm 平台梁下与室内地面净高差2400-400=2000mm , 满足平台下过人要求净高≥2000mm ,故无需降低平台梁下地面标高。 第二梯段:踏步数26-16=10,踏面数9。 水平长度=300×9=2700mm 。 二层以上每跑梯段踏步数相等26/2=13,水平面长度=300×12=3600mm 。 核算首层中间平台到二层平台底的净高(3.9+1.95)-2.4=3.45m > 2.2m ,满足要求。 (2)楼梯丁(净面积6950×7150)计算(中间梯段宽取3000mm ,两边梯段宽取1800 mm ): 设h =150mm ,N=1503900 =26, 2h +b =600~620mm 且h +b ≈450mm ,取b =300mm 。 平台宽度≥900+300=1200,取1900mm 。 第一梯段:7150-1900-600=4650mm 4650/300=15.5,取15步。

平台实际长度=300×15=4500mm 首层平台高度=150×16=2400mm 平台梁下与室内地面净高差2400-400=2000mm , 满足平台下过人要求净高≥2000mm ,故无需降低平台梁下地面标高。 第二梯段:踏步数26-16=10,踏面数9。 水平长度=300×9=2700mm 。 二层以上每跑梯段踏步数相等26/2=13,水平面长度=300×12=3600mm 。 核算首层中间平台到二层平台底的净高(3.9+1.95)-2.4=3.45m > 2.2m ,满足要求。 9.2 楼梯斜板设计 以下均以楼梯甲的设计为例。 考虑到第一跑楼梯梯段斜板两端与混凝土楼梯梁的固结作用,斜板跨度可按净跨计算,对斜板取1m 宽作为其计算单元。 (1)确定斜板厚度t ,斜板的水平投影净长l 1n =300×12=3600mm 斜板的斜向净长l′1n =mm l n 4027894 .03600 300150/3003600cos 2 21== += α 斜板厚度t 1 =n l 1 )30 1 ~251( '= (134~161)mm,取板厚t 1 =140mm (2)荷载计算,楼梯梯段斜板的荷载计算列于下表(取1m 宽的板带作为计算单元): 表9-1 楼梯梯段斜板的荷载计算表

自动水位液位电脑控制器说明书

微电脑自动液位(水位)控制器使用说明书 本产品采用微电脑自动控制,外形轻便小巧,安装方便,信号线+\P1\P2\P3\多为低压5V,并结合高层楼宇上、下水池(水塔)的水位分级控制,并具有上下水池联合控制,水池排水及多项功能,可自动实现水箱补水、排水、并有效防止水池水位过高溢出或水泵空转或堵转损坏。非常适合城镇家庭、农村、学校、工况企事业单位的供水工程,广泛应用于印染、化工、食品、饮料、酿酒、制糖等行业。 安装调试可以按照以下步骤进行 一、按照本说明书后面的图《控制盒拆开方法》打开本塑料保护盒,将交流电压接到(输入)端子,请将电机接到(输出控制)端子,其他水位传感信号线按照您自己需要的功能,参照接线方法图纸接线。接好线后必须安装塑料保护外壳,然后才可以给本机上电。 二、使用方法 开机时显示型号(型号和相对功能见选型表) 电机参数修改方法:按住F 健不放开再开机,直到显示###,再放开F 健,水泵自动启动,等到水泵正常供水(已经稳定),再按F 键一次,自动记录当前电机参数,自动返回正常使用。 水位传感器信号查看方法:开机约50秒后按住F 键不放,显示###,表示P1线水位信号,再接1次F 键显示###,表示P2线水位信号,再按F 键一次,显示###,表示P3线水位信号。再按一次F 键,显示###,表示当前电机启动后的参数。 水位显示含义:显示 表示低水位 显示第2位一点表示下水池无水 显示 表示低水位 显示第2位两点表示下水池有水 显示表示低水位手动控制法:按A 键或B 键进入手动控制,再按A 键启动输出,按B 键停止输出,按F 键退出手动控制功能,返回自动控制。 电机过载保护后关闭输出并且显示 ,按A 键退回到正常使用。电机空载保护后关闭输出并且显示,按A 键退回到正常使用。 直接可控制 220V 1.2KW 外配接触器 380V 15KW 缺水保护,溢出保护,空载保护,过载保护,堵转保护,故障记忆。. JLD

钢筋混凝土板式楼梯设计楼梯板及平台板配筋图

钢筋混凝土板式楼梯设计楼梯板及平台板配筋 图 内部编号:(YUUT-TBBY-MMUT-URRUY-UOOY-DBUYI-0128)

六、钢筋混凝土板式楼梯设计 楼梯设计包括建筑设计和结构设计两部分。 一、设计资料 建筑设计 1、楼梯间建筑平面,开间:3300mm。进深:4800mm。 5楼梯形式尺寸:双跑楼梯,层高4600mm,踏步采用180mm×270mm,每层共需4600/180=25步。如图建筑图中所示。 二、结构设计采用板式楼梯 1、楼梯梯段板计算: 混凝土采用C20,单d≤10mm时,采用Ⅰ级钢筋;单d≥12mm时,采用Ⅱ级钢筋,fc=9.6kN/mm2,fy=210 kN/mm2 2假定板厚:h=l/30=2700/30=90mm,取h=100mm。 3荷载计算(取1米板宽计算) 楼梯斜板倾角: a=tg-1(180/270)=26.530 cosa=0.895 恒载计算: 踏步重(1.0/0.3)×0.5×0.15×0.3×25=1.875 kN/m 斜板重(1.0/0.895)×0.1×25=2.8kN/m 20mm厚面层粉刷层重: [(0.3+0.15)/0.3]×0.02×20×1.0=0.6kN/m 15mm厚板底抹灰: (1.0/0.895)×0.015×17=0.32kN/m

恒载标准值 gk=1.875+2.8+0.60+0.29=5.57 kN/m 恒载设计值 gd=1.2×5.57=6.68 kN/m 活载计算: 活载标准值 Pk=2.5×1.0=2.5 kN/m 活载设计值 Pd=1.4×2.5=3.5 kN/m 总荷载设计值 qd=gd+pd=6.68+3.5=10.18kN/m (3)内力计算 跨中弯矩:M=qdl2/10=10.18×2.72/10=7.42 kN.m (4)配筋计算(结构重要系数r =1.0) h0= h-20=100-20=80mm ɑs=r 0M/(fcbh 2)=1.0×7.42×106/(9.6×1000×802)=0.12 ξ=1-(1-2ɑs)0.5=0.1282 As= fcbh ξ/fy=9.6×1000×0.1282×80/210=468.85mm2 受力钢筋选用10@150(As=604 mm2) 分布钢筋选用6@300 2、平台板计算 (1)荷载计算(取1米板宽计算) 假定板厚80mm,平台梁TL-1截面尺寸200×300mm,TL-2截面尺寸为150×300mm。 楼梯板及平台板配筋图 恒载:平台板自重 0.08×1.0×25=2 kN/m 20mm厚抹面: 0.02×1.0×20=0.4kN/m

相关文档
最新文档