Keysight PNA Network Analyzer Data Sheet and Technical Specifications
N5222A PNA 微波网络分析仪 _ Agilent

关于 Agilent 隐私声明 使用条款 商标确认 与安捷伦联系 关于 Agilent
站点反馈
/zh-CN/pd-2001963-pn-N5222A/pna-microwave-network-analyzer?cc=CN&lc=chi[2014/7/8 14:20:23]
查看全部
/zh-CN/pd-2001963-pn-N5222A/pna-microwave-network-analyzer?cc=CN&lc=chi[2014/7/8 14:20:23]
N5222A PNA 微波网络分析仪 | Agilent
价格: 中国
* 价格如有变更,恕不另行通知。 显示价格为厂商建议零售 价(MSRP)。
概述与特性
选件与附件
资料库
主要特性与技术指标
10 MHz 至 26.5 GHz 2 端口(单信号源)或 4 端口(2 个内置信号源) 127 dB 系统和 132 dB 接收机动态范围、32,001 个点、200 个通道、15 MHz 中频带宽 高输出功率(+13 dBm)和宽功率扫描范围(38 dB) 最佳动态精度:在测试端接口使用 0.1 dB 压缩和 +12 dBm 输入功率 在 10 Hz 中频带宽时仅有 -114 dBm 的低本底噪声
培训与活动
New Calibration Method Simplifies Measurements of Fixtured Devices Webcast Network Analysis Back to Basics Webcast Taking the mystery out of mmwave and THz measurements
技术支持 文档资料库 驱动程序、固化软件和软件 常见问题 培训与活动 论坛 产品服务信息 备件 维修和校准服务
兼具速度和性能优势的 PNA-B网络分析仪简介

针对全系列 PNA 产品灵活选择许可证类型, 优化 您的软件投资
– 新的软件许可证授权方案 – 之前的软件选件更改为型号编号 (例如选件 010 → S93010A) – 可以随仪器一起订购或以后再增加 – 提供可转移许可证和基于时限的 (1 年) 许可证
用户界面焕然一新
– 简化的硬键和下拉菜单组群 – 标签式功能键, 便于更灵活地设置项目 – 触摸并保持屏幕, 支持进行鼠标右键选择 – 多点触控缩放 – 工具 (快捷键图标) – 工作表 (设置选项卡) – 更完整的状态栏
PNA A 系列升级到 B 系列相关信息 PNA 系列
N5221B 10 MHz 至 13.5 GHz N5222B 10 MHz 至 26.5 GHz N5224B 10 MHz 至 43.5 GHz N5225B 10 MHz 至 50 GHz N5227B 10 MHz 至 67 GHz N5264B 天线接收机 – 最小升级包括: 新的硬盘、 前面板配件、 以及采用新配色方案的外部部件 (盖子、 手柄、 皮 带、 支脚) – 超过一定年限的仪表, 可能需要更换额外的硬件 (例如 CPU、 DSP、 合成器组件) – 选件 H29 (在 50 GHz PNA-X 中的 26.5 GHz 噪声硬件) 必须升级至新噪声硬件
产品快报
Keysight PNA-B 系列微波网络分析仪
高效实现卓越性能
当您表征有源器件时, 兼具速度和性能优势的 PNA-B 能够让您如虎添翼。 更直观的图形用户界面可以实现更高性 能的网络分析; 借助超值的应用软件, 可以显著提高测量质量。
快速提供出色结果
– 与 A 系列 PNA 具有同等出色的射频硬件和测试性能 – 宽屏 (12.1 英寸) 、 多点触控显示屏 – 简单、 直观的全新用户界面 – VNA 测试 软件全面支持 ENA、 PNA 和模块化产品
Keysight E5063A ENA Series Network Analyzer 配置指南说明

E5063A-810E5063A-820E5063A/205E5063A/205/GPIB E5063A/215 E5063A/235E5063A/245E5063A/245/GPIB E5063A/265E5063A/285Keysight E5063AENA Series Network Analyzer100 kHz to 500 M/1.5 G/3 G/4.5 G/6.5 G/8.5 G/14 G/18 GHzConfiguration Guide02 | Keysight | E5063A ENA Series Network Analyzer - Configuration GuideOrdering GuideThe following steps will guide you through configuring your Keysight Technologies’ E5063A.Standard furnished itemDescription Additional informationInstallation guide Contains the information necessary to start up with the E5063A.CD ROM IO librariesPower CableCalibration of CertificationStep 1. Choose frequency option (must choose one of the eight frequency options.) Description Option no. Network Analyzer 100 kHz to 500 MHz, S-parameter test set, 50 Ω system impedance E5063A-205 Network Analyzer 100 kHz to 1.5 GHz, S-parameter test set, 50 Ω system impedance E5063A-215 Network Analyzer 100 kHz to 3 GHz, S-parameter test set, 50 Ω system impedance E5063A-235 Network Analyzer 100 kHz to 4.5 GHz, S-parameter test set, 50 Ω system impedance E5063A-245 Network Analyzer 100 kHz to 6.5 GHz, S-parameter test set, 50 Ω system impedance E5063A-265 Network Analyzer 100 kHz to 8.5 GHz, S-parameter test set, 50 Ω system impedance E5063A-285 Network Analyzer 100 kHz to 14 GHz, S-parameter test set, 50 Ω system impedance E5063A-2D5 Network Analyzer 100 kHz to 18 GHz, S-parameter test set, 50 Ω system impedance E5063A-2H5Step 2. Choose software option (If not required, go to step 4.)Description Option no.Requires Not compatible Additional informationTime Domain/Test wizard E5063A-011None None1This option is required for time domain analysis or PCBmeasurementsTime Domain E5063A-010None E5063A-011Adds time domain transform and gating capabilitiesWireless power transfer analysis E5063A-006None None This option is required for wireless power transfer efficiency test ofwireless power transfer modules1. E5063A-011 is a superset of E5063A-010. E5063A-011 includes the capability of E5063A-010.Step 3. Choose hardware optionDescription Option no.Requires Not compatible Additional informationAdd GPIB interface E5063A-721None E5063A-722Must choose either Option 721 or 722Without GPIB interface E5063A-722None E5063A-721Must choose either Option 721 or 722Add handler I/O interface E5063A-731None E5063A-732Must choose either Option 731 or 732Without handler I/O interface E5063A-732None E5063A-731Must choose either Option 731 or 732Step 4. Choose storage drive option (mandatory option)Description Option no.Requires Not compatible Additional informationStandard storage drive E5063A-019None None Option 019 is the only storage drive option for the E5063A.Must choose this option03 | Keysight | E5063A ENA Series Network Analyzer - Configuration GuideStep 6. Add calibration certificate (If not required, go to step 7.)DescriptionOption no.Additional information ISO 17025 Compliant Calibration E5063A-1A7ISO 17025 compliant calibration ANSI Z540 compliant calibrationE5063A-A6JANSI Z540 compliant calibrationStep 5. Add accessory option (If not required, go to step 6.)Description Option no.Requires Not compatible Additional informationKeyboard E5063A-810None None USB Keyboard for simplifying word inputs.Mouse E5063A-820None None USB Mouse for simplifying measurement operation.Rackmount Kit E5063A-1CM None None Not installable simultaneously with E5063A -1CP.Front Handle Kit E5063A-1CN None None Not installable simultaneously with E5063A -1CP.Handle/Rack Mount KitE5063A-1CPNoneNoneNot installable simultaneously with E5063A -1CM or 1CN.Step 8. Add related productsDescription Option no.Requires Not compatible Additional informationUSB Coaxial Switch, DC to 18 GHz, SPDTU1810BNoneNoneThe number of test ports can be expanded up to four by connecting this SPDT switch to the E5063A’s port-1 and 2.–For connecting both single-ended and differential probes simultaneously in the PCB measurements with the option E5063A-011. –For testing multiple DUTs with one E5063A.USB Coaxial Switch, DC to 8 GHz Dual SP6T U1816A None NoneThe number of test ports can be expanded up to 12 by connecting this SP6T switch to the E5063A’s ports, which can provides a lower cost solution for multi-DUT (antenna) measurementsUSB Coaxial Switch,DC to 26.5 GHz Dual SP6TU1816C None NoneThe number of test ports can be expanded up to 12 by connecting this SP6T switch to the E5063A’s ports, which can provides a lower cost solution for multi-DUT (antenna) measurements1. The U1810B’s switching can be controlled with the graphical user interface of the option 011 Test Wizard, or with the E5063A’s SCPI command.(This command can be used even without the Option 011.)Step 7. Choose warranty plan3 year return-to-keysight warranty and service is standard. The extended warranty option is available. Contact your local Keysight office or visit our web site for more information.04 | Keysight | E5063A ENA Series Network Analyzer - Configuration GuideFrequency UpgradesUpgrade kit option no.Description From To Customer installable E5063AU-210Upgrade from 500 MHz to 1.5 GHz E5063A-205E5063A-215NoE5063AU-230Upgrade from 500 MHz to 3 GHz E5063A-205E5063A-235NoE5063AU-240Upgrade from 500 MHz to 4.5 GHz E5063A-205E5063A-245NoE5063AU-260Upgrade from 500 MHz to 6.5 GHz E5063A-205E5063A-265NoE5063AU-280Upgrade from 500 MHz to 8.5 GHz E5063A-205E5063A-285NoE5063AU-2D0Upgrade from 500 MHz to 14 GHz E5063A-205E5063A-2D5NoE5063AU-2H0Upgrade from 500 MHz to 18 GHz E5063A-205E5063A-2H5NoE5063AU-231Upgrade from 1.5 GHz to 3 GHz E5063A-215E5063A-235NoE5063AU-241Upgrade from 1.5 GHz to 4.5 GHz E5063A-215E5063A-245NoE5063AU-261Upgrade from 1.5 GHz to 6.5 GHz E5063A-215E5063A-265NoE5063AU-281Upgrade from 1.5 GHz to 8.5 GHz E5063A-215E5063A-285NoE5063AU-2D1Upgrade from 1.5 GHz to 14 GHz E5063A-215E5063A-2D5NoE5063AU-2H1Upgrade from 1.5 GHz to 18 GHz E5063A-215E5063A-2H5NoE5063AU-243Upgrade from 3 GHz to 4.5 GHz E5063A-235E5063A-245NoE5063AU-263Upgrade from 3 GHz to 6.5 GHz E5063A-235E5063A-265NoE5063AU-283Upgrade from 3 GHz to 8.5 GHz E5063A-235E5063A-285NoE5063AU-2D3Upgrade from 3 GHz to 14 GHz E5063A-235E5063A-2D5NoE5063AU-2H3Upgrade from 3 GHz to 18 GHz E5063A-235E5063A-2H5NoE5063AU-265Upgrade from 4.5 GHz to 6.5 GHz E5063A-245E5063A-265NoE5063AU-285Upgrade from 4.5 GHz to 8.5 GHz E5063A-245E5063A-285NoE5063AU-2D5Upgrade from 4.5 GHz to 14 GHz E5063A-245E5063A-2D5NoE5063AU-2H5Upgrade from 4.5 GHz to 18 GHz E5063A-245E5063A-2H5NoE5063AU-286Upgrade from 6.5 GHz to 8.5 GHz E5063A-265E5063A-285NoE5063AU-2D6Upgrade from 6.5 GHz to 14 GHz E5063A-265E5063A-2D5NoE5063AU-2H7Upgrade from 6.5 GHz to 18 GHz E5063A-265E5063A-2H5NoE5063AU-2D8Upgrade from 8.5 GHz to 14 GHz E5063A-285E5063A-2D5NoE5063AU-2H6Upgrade from 8.5 GHz to 18 GHz E5063A-285E5063A-2H5NoE5063AU-2HD Upgrade from 14 GHz to 18 GHz E5063A-2D5E5063A-2H5No Hardware UpgradesUpgrade model no.Description Option no.CustomerinstallableRequires (Instrument mustalready include the following)E5063AU-721Add GPIB interface E5063A-721No None E5063AU-731Add handler I/O interface E5063A-731No NoneSoftware UpgradesUpgrade model no. Description Option no.CustomerinstallableRequires (Instrument mustalready include the following)Additional informationE5063AU-011Time Domain/Test wizard E5063A-011Yes None This option is required for time domainanalysis or PCB measurementsE5063AU-010Time Domain E5063A-010Yes None Adds time domain transform andgating capabilitiesE5063AU-006Wireless power transferanalysis E5063A-006Yes None This option is required for wirelesspower transfer efficiency test ofwireless power transfer modules05 | Keysight | E5063A ENA Series Network Analyzer - Configuration GuideTest Accessories and Calibration KitsTest accessories and calibration kits that can be used with the E5063A are listed in this section. A complete line of test accessories and calibration kits can be found at the following websites:/find/na_accessories/find/accessoriesTest accessoriesTest accessories such as test port cable are necessary for a complete measurement system using the E5063A. Order test accessories in accordance with the desired measurement system.Category Product Number DescriptionCables N6314A 50 Ω type-N (m) to type-N (m) cable, DC to 12.4 GHz, 61 cm (24 in)N6315A50 Ω type-N (m) to type-N (f) cable, DC to 12.4 GHz, 61 cm (24 in)11500E 3.5 mm (m) to 3.5 mm (m) cable, 61 cm (24 in)11500F 3.5 mm (m) to 3.5 mm (m) cable, 152 cm (60 in)Adapters11853A50 Ω Type-N accessory kit11878A Type-N to 3.5 mm adapter kitCalibration kitsCalibration is an accuracy enhancement procedure that effectively reduces the system errors that cause uncertainty in network measurement. Calibration kit is necessary to perform the calibration.–Mechanical calibration kits include standards, such as opens, shorts and loads, which are measured by the network analyzer.Choose a calibration kit for each connector type to be used.–Electronic calibration (ECal) modules replace mechanical calibration standards with one solid-state calibration module that is controlled by the network analyzer via USB. ECal modules provide many different impedances to the test ports which enables a full two-port calibration to be performed quickly with a single connection. This technique reduces operator errors and connector wear and abrasion.Category Product Number DescriptionMechanical calibration kits85032F Standard Mechanical Calibration Kit, DC to 9 GHz, Type-N, 50 Ω85054D Economy Mechanical Calibration Kit, DC to 18 GHz, Type-N, 50 ΩElectronic calibration kits85092C RF ECal: 300 kHz to 9 GHz, 2 ports, Type-N, 50 ΩN4431B Microwave ECal: 9 kHz to 13.5 GHz, 4 portsN4432A Microwave ECal: 300 kHz to 18 GHz, 4 portsN4690C Microwave ECal: 300 kHz to 18 GHz, 2 ports, Type-N, 50 ΩLiterature ResourceDescription Publication numberE5063A Network Analyzer Data Sheet5991-3615ENE5063A Network Analyzer Brochure5991-3614ENE5063A PCB Analyzer Technical Overview5991-3617ENNetwork Analyzers Selection Guide5989-7603ENMore literature is available on our web site.Web ResourceGet the latest news, product and support information, application literature and more./find/e5063a06 | Keysight | E5063A ENA Series Network Analyzer - Configuration GuideFor more information on KeysightTechnologies’ products, applications or services, please contact your local Keysight office. The complete list is available at:/find/contactus Americas Canada (877) 894 4414Brazil 55 11 3351 7010Mexico001 800 254 2440United States (800) 829 4444Asia Pacific Australia 1 800 629 485China800 810 0189Hong Kong 800 938 693India 1 800 11 2626Japan 0120 (421) 345Korea 080 769 0800Malaysia 1 800 888 848Singapore 180****8100Taiwan0800 047 866Other AP Countries (65) 6375 8100Europe & Middle East Austria 0800 001122Belgium 0800 58580Finland 0800 523252France 0805 980333Germany ***********Ireland 1800 832700Israel 1 809 343051Italy800 599100Luxembourg +32 800 58580Netherlands 0800 0233200Russia 8800 5009286Spain 800 000154Sweden 0200 882255Switzerland0800 805353Opt. 1 (DE)Opt. 2 (FR)Opt. 3 (IT)United Kingdom0800 0260637For other unlisted countries:/find/contactus(BP-11-29-16)/go/quality Keysight Technologies, Inc.DEKRA Certified ISO 9001:2015Quality Management SystemThis information is subject to change without notice.© Keysight Technologies, 2013 - 2017Published in USA, January 18, 20175991-3616EN/find/e5063aEvolvingOur unique combination of hardware, software, support, and people can help you reach your next breakthrough.We are unlocking the future of technology.From Hewlett-Packard to Agilent to KeysightmyKeysight/find/mykeysightA personalized view into the information most relevant to you.Keysight Services/find/serviceOur deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. The result? We help you implement new technologies and engineer improved processes thatlower costs.Three-Year Warranty/find/ThreeYearWarrantyKeysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company withthree-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems andcustom products.Keysight Assurance Plans/find/AssurancePlansUp to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements.Keysight Channel Partners/find/channelpartnersGet the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience.E5063A/2D5E5063A/2H5E5063A/2H5/GPIB E5063A-1CN E5063AU-010E5063A-810E5063A-820E5063A/205E5063A/205/GPIB E5063A/215 E5063A/235E5063A/245E5063A/245/GPIB E5063A/265E5063A/285。
Keysight PNA微波网络分析仪系列产品说明书

Keysight TechnologiesPNA MicrowaveNetwork AnalyzersPNA Network Analyzers:E8362/3/4B, E8361A10 MHz to 20, 40, 50, 67, or 110 GHzPNA-L Network Analyzers:N5230A300 kHz to 6, 13.5, or 20 GHz10 MHz to 20, 40, or 50 GHzPNA-X Network Analyzers:N5242A10 MHz to 26.5 GHzWelcome to The World of PNAs –The Most Popular Microwave Network AnalyzersThe PNA Series builds on Keysight Technologies Inc. 40-year legacy of excellence todeliver new standards in speed, accuracy, and versatility for microwave network analysis. The PNA’s architecture includes high quality, stable hardware and lexible software. The standard PNA is suitable for testing passive and active devices such as ilters and ampliiers. Users can easily add options to test mixers, harmonics, intermodulation distortion (IMD), pulsed-RF, antennas and millimeter-wave (mmwave) components.Key features–Excellent performance–High dynamic range: 127 dB at 20 GHz at test port –Low trace noise: 0.002 dB rms at 1 kHz bandwidth –Fast measurement speed: 4.5 to 26 µsec/point –High stability: 0.05 dB/degrees Celsius–State-of-the-art calibration capabilities and wide-range of ECal modules –Advanced applications for mixer and pulse measurements –Single-ended and balanced measurements–32 measurement channels, unlimited traces, and 16,001 points per channel –Connectivity with Open Windows XP, 6 USB connectors, LAN, and GPIBPNA modelsPNA PNA-L PNA-X300 kHz to 6 GHz300 kHz to 13.5 GHz300 kHz to 20 GHz10 MHz to 20 GHz10 MHz to 40 GHz10 MHz to 50 GHz22 ports 10 MHzto 20 GHz10 MHzto 40 GHz10 MHzto 50 GHz10 MHzto 67 GHz10 MHzto 110 GHz10 MHz to 26.5 GHzCommon Features Across the PNA SeriesThe PNA-X integrates a 10.4 inch high resolution display with a touch screen, which provides a crisp view and easy access to all data and traces. This enhanced user interfaceallows intuitive operation and helps you set upcomplex measurements quickly.Flexible user interface:hard keys, soft keys, and pull-down menus Up to10 markers per trace32 measurement channels and unlimited traces State-of-the-art calibration capabilitiesOn-line HelpConigurable test set availableon all models Linear, log, power, CW, and segment sweep Equation editor and time-domainanalysis Quick access for ECal and otherUSB devicesPNA-X – The Premier-Performance Microwave Network AnalyzerThe industry-leading performance and highly integrated conigurable nature of the PNA-X make it the ideal solution to address active device measurement challenges.The PNA-X enables engineers to stay on the leading edge of component testing.High quality synthesizers–10 MHz to 26.5 GHz–Internal 2nd source for IMD, hot-S22, and high speed swept-LO measurements –High output power and wide power-sweep range for testing ampliiers–Excellent harmonic performance for accurate harmonic and IMD measurementsSensitive and linear receivers–High compression point for improved dynamic accuracy –More sensitivity for pulsed S-parameter measurementsFriendly user interface–Large 10.4 inch touch screen display –Click-and-drag markers and zoomExceptional lexibility–Built-in signal combiner for easy IMD and hot-S 22 measurements–Easy pulsed measurements with internal pulse modulators and pulse generators –Flexible signal routing via internal switches for adding external ilters, pre-ampliiers, and additional test equipment–Optional noise igure measurement capability extends the suite of measurements available with a single connection and offers the industry’s highest accuracy –Front-panel jumpers for direct access to test-port couplers and receivers–Source and receiver attenuators with 5 dB increments for better measurement optimization–Built-in bias-tees simplify ampliier evaluation–Three sets of triggering lines for complex test systemsPNA-X block diagram (shown with Options 400, 419, and 423).Built-in signal combiner Internal switches for routingexternal signalsPNA-X – Testing Beyond The Limits –Mixers and ConvertersPNA’s frequency offset capability offers industry-leading accuracy and ease-of-use for measuringmixers and frequency converters.Mixer measurementsChecklist–Conversion loss/gain, magnitude and phase–Input match, output match, and LO match–Isolation and compression–The two internal independent synthesizers with +13 dBm power and < 60 dBcharmonics eliminate the need for external synthesizers or components.–Advanced error correction–Patented vector-mixer calibration for measurement of absolute group delay–Scalar-mixer calibration (SMC) for match-corrected amplitude measurements–Signiicantly faster speed for ixed-IF (20 to 30 times faster than with an externalsource)–Easy-to-conigure multi-stage converter measurements–LO source control and LO power calibration–Mixer IMD–The simple two-step SMC calibration provides match-corrected conversion loss,error-corrected input and output match–Software tuning for embedded LOPNA-X – Ahead of The Curve – Ampliiers, Pulsed-RFThe PNA-X is an ideal tool for measuring ampliierspeciications, from gain and return loss, toharmonics and IMD.Ampliier measurementsChecklist–Gain, gain latness, reverse isolation, and return loss–Simple, fast, and accurate AM-AM and AM-PM compression measurements with the Gain Compression Application with 38 dB power sweep range at 20 GHz, +13 dBmoutput power–Test harmonics accurately with < 60 dBc source harmonics. No need for externalilters.– Accurate and simple IMD using the dual sources and internal combiner, locatedbehind the couplers, providing highly accurate and stable measurements. No needfor external combiners.–S ource corrected noise igure measurements with exceptional accuracy–I ntegrated source attenuators and receiver attenuators for measurementoptimization–Perform all of the above measurements with one single connection using thePNA–X.Pulsed-RF measurementsChecklist–Wideband and narrowband detection–Up to four internal pulse generators–U p to two internal pulse modulators–Pulse widths as narrow as 33 ns–Pulse-to-pulse–Point-in-pulse, average pulse, and pulse-proile capability–No need for external componentsUse TRL calibration for accurate in-ixture, on-wafer, or waveguide measurements.The Keysight PNA-L is designed for your general-purpose network analysis needs and priced for your budget. With the same irmware as the PNA, the PNA-L offers the perfect balance of value and performance. PNA-L provides eficiency and lexibility in both manufacturing and R&D applications, for industries ranging from wireless LAN component production to aerospace and defense.Basic measurements Checklist–Insertion loss, gain, return loss, isolation, group delay, compression, both magnitude and phase–Connectorized, in-ixture, or on-wafer –Fast and accurate–Reliable and repeatable –AffordableOn-wafer measurements Checklist–Class of TRL calibrations for accurate measurements–Differential measurement capabilities with integrated multiport network analyzers –Accurate power control and de-embedding algorithm for device characterization –Compatibility with on-wafer calibration software for a total solutionPNA-L – Speed and Accuracy You Can Count On – Balanced/Differential Measurements and Multiport TestEasily measure single-ended, balanced, and mixed-mode S-parameters,in addition to ratioed and unratioed receiver measurements.New multiport components require complicated test plans. Multiple port combinations must be tested over several frequency bands, resulting in lengthy tests. To reduce test time and lower costs, the PNA-L/PNA-X and test set combinations have been designed for high-speed measurements. To further simplify complex test requirements, up to 32 independent channels are available, eliminating the need for recalling instrument states.Adding a 4-port test set expands the 4-port PNA-L to an 8-port system with full 8-port mea-surement capabilities.GSM/TDMA Rx GSM/TDMA Tx GSM/TDMA Tx GSM Rx TDMA RxDifferential measurements Checklist–Single-ended, balanced, mixed-mode –S-parameters–Ratioed and unratioed measurements –Mode-conversion analysis–True-mode stimulus measurementsMultiport measurements Checklist–Multiport conigurations optimized for your device, including full cross-bar –Quick-Short-Open-Load-Thru (QSOLT) for fast, multiport cal –N-port calibration for accuracy and ease-of-measurements –Test-set control part of PNA irmware–32 independent channels for fast measurement speedTri-band antenna switch module with balanced and single-ended ports.PNA – The Solution for Your Mmwave NeedsThe N5250A PNA-based mmwave system has superb dynamic range. Shown hereis the S21 of a ilter at 94 GHz, compared to the 8510XF.Use time domain to gate out the response of ixtures and cables, and characterizethe impedance of transmission lines.Millimeter-wave measurementsChecklist–PNA-based 10 MHz to 110 GHz bench-top system, extendable to 325 GHz –Compact test-heads and two built-in synthesizers, for up to 110 GHz–Highly stable systems–No external synthesizes to 325 GHz, when used with PNA-X–Supported applications – pulsed-RF, antenna, and on-waferTime-domain analysisChecklist–Locate and resolve mismatches in the ixture, cable, or transmission lines –Use gating to remove unwanted responses–Fault-locationPNA Series Simpliies Measurements – When the Requirements are Dificult Modeling, PLTS, Antenna, Materials TestHigh-frequency design and modelingChecklist–PNA drivers included in Connection Manager for easy connectivity–Simple downloading of S-parameters into ADS for simulation–Save “.s2p, .s4p, snp” iles and import into ADS–M odeling of devices using IC-CAP and PNA network analyzersPhysical Layer Test Systems (PLTS)Checklist–RLCG model extraction and eye-diagrams–High-speed differential interconnect design–Multiple aggressor differential crosstalkAntenna measurementsChecklist–20,001 points per channel–Fast measurement speed, 4.5 µs/pt–Forward and reverse sweeps for near-ield scans–High-sensitivityMaterials measurementsChecklist–Measurement of dielectric and magnetic properties–Viewing of data in real, imaginary, loss tangent, and Cole-Cole formats–Availability of a variety of techniques to meet your materials needsPNA-L/PNA/PNA-X Comparison Table: Solution available Blank : Solution not available Good and superb : Solution available, quality of solution qualiied. For example, withmaximum output power levels, all PNAs have output power, but thePNA-X has the highest output power.1. 4-port PNA-L has one source attenuator. 4-port PNA-X has 4 source attenuators.2. Applicable to high-power ampliier testing or integration of the external test equipment.PNA – State-Of-The-Art Calibration CapabilitiesHigh-performance ECal modules–High-performance ECal modules, 10 MHz to–26.5 GHz, 10 MHz to 67 GHz and more–Nine connector types, mixed-connector modules–U ser characterization for adding adaptersCalibration for non-insertable devices–Unknown through calibration–QSOLT and n-port calibration (6-port, 8-port, 12-port, etc)for multiport test systems–Databased-model and expanded math calibrations for highest accuracyIn-ixture measurements–Frequency response cal, 1-port cal, 2-port cal, enhanced response-cal, TRL/TRM cal and adapter-removal cal–An easy-to-use uncertainty calculator, and a comprehensive application note on calibration standards–Automatic port extension removes loss and delay for in-ixture devicesAdvanced mixer and ampliier calibrations–The patented vector mixer calibration and the popular scalar-mixer calibration–De-embedding of attenuators and the new fast source power calibration technique for ampliier measurements–De-embedding of probes and waveguides in mixer measurements–Unique noise igure calibration removes the effects of imperfect system source matchPNA - The standard for accuracyAll the network analyzers in the PNA family are known for their high-levels of stability, contributing to accurate calibrationsand measurements. With the PNA-X, users can beneit from exceptional levels of dynamic accuracy. For users in non-linear environments, the PNA’s Scalar Mixer Calibration provides a higher level of measurement accuracy.Stability of a 20 GHz PNA over a 30-hour period1 It is clear that the more stable the hardware, the better the calibration, since it can correct the errors better. The calibration will remain stable as a function of time and temperature, and calibrations will not need to be updated as often.Typical dynamic accuracy of a PNA-X, with –20dBm powerIf you are measuring a device with 20 dB insertion loss, the contribution of the dynamic accuracy error (receiver linearity) is less than 0.01 dB.Scalar-mixer calibration versus a simple power meter/receiver calibrationNote the effects of mismatch that are corrected for by SMC.110 GHz PNA drift over a 24-hour period1As you can see on the graph, the 110 GHz PNA drifts less than 0.7 dB, after 24 hours, at 110 GHz. Keysight’s 110 GHz PNA system is the most stable mmwave system in the industry.1. Measurements made at 25 ± 1 degree Celcuis.Outstanding Performance# of ports22424 Dynamic range1123 dB108 dB103 dB127 dB127 dB Noise loor–120 dBm–105 dBm–106 dBm–114 dBm–114 dBm Max output power+3 dBm+3 dBm–3 dBm+13 dBm+13 dBm 0.1 dB compression–5 dBm input+6 dBm input+9 dBm input+12 dBm input+12 dBm inputTrace noise0.006 dB rms1 kHz IFBW0 dBm 0.006 dB rms1 kHz IFBW–5 dBm0.010 dB rms100 kHz IFBW–5 dBm0.005 dB rms100 kHz IFBW–5 dBm0.005 dB rms100 kHz IFBW–5 dBmALC range27 dB23 dB22 dB38 dB38 dB Max IFBW40 kHz250 kHz600 kHz 5 MHz 5 MHz Speed26 µs/pt9 µs/pt 4.5 µs/pt 4.5 µs/pt 4.5 µs/pt Display size, LCD21.3 cm21.3 cm21.3 cm26.4 cm26.4 cm Touch screen No No No Yes Yes1.20 GHz, test port, 10 Hz IFBW.Dynamic range123 dB108 dBNoise loor–120 dBm–105 dBmMax output power+3 dBm+3 dBm0.1 dB compression–5 dBm input+6 dBm inputTrace noise (1 kHz)0.006 dB rms1 kHz IFBW0 dBm 0.006 dB rms1 kHz IFBW–5 dBmALC range27 dB23 dB Max IFBW40 kHz250 kHz Speed26 µs/pt9 µs/ptCompleting The SolutionProtect conidential dataThe best method for maintaining security is to remove the hard disk drive. The PNA pro-vides the removable hard disk drive as a standard feature, enabling you to easily remove the drive and keep it safe in a secure area.Protect your software investmentKeysight protects your 8753, 8720 and 8510 software investment by providing migration tools to reduce your code conversion effort./find/nadiscoNetwork analyzer forumVisit the online network analyzer discussion forum where you can learn how your peers are solving some of their most challenging measurement problems./ind/agilent_naforumFree CD - Network analyzer application notes and video demos Application topics include ampliiers, mixers/converters, pulsed-RF, millimeter/sub millimeter-wave, and materials measurements./ind/nacdWeb ResourcesVisit our Web sites for additional product information and literature. PNA-X microwave network analyzers/find/pna-xPNA-L microwave network analyzers/find/pnalPNA microwave network analyzers/find/pnaENA RF network analyzers/find/enaPhysical layer test systems/find/pltsMultiport test solutions/find/multiportAntenna test/find/antennaElectronic calibration (ECal) modules/find/ecalRF and microwave accessories/find/accessoriesMechanical and electronic calibrationkits and pulsed-RF measurements/find/pulsedrfKeysight RF & microwave networkanalyzer calibration resources/find/nacalRF and microwave network analysis and impedance probings /find/probingrfMaterials measurements/find/materialsBalanced measurements/find/balancedmyKeysight/find/mykeysightA personalized view into the information most relevant to you.Three-Year Warranty/find/ThreeYearWarrantyKeysight’s commitment to superior product quality and lower total costof ownership. The only test and measurement company with three-yearwarranty standard on all instruments, worldwide.Keysight Assurance Plans/find/AssurancePlansUp to five years of protection and no budgetary surprises to ensure yourinstruments are operating to specification so you can rely on accuratemeasurements./qualityKeysight Technologies, Inc.DEKRA Certified ISO 9001:2008Quality Management SystemKeysight Channel Partners/find/channelpartnersGet the best of both worlds: Keysight’s measurement expertise and productbreadth, combined with channel partner convenience./find/pnaThis information is subject to change without notice.© Keysight Technologies, 2007 - 2014Published in USA, July 31, 20145989-6014ENFor more information on KeysightTechnologies’ products, applications orservices, please contact your local Keysightoffice. The complete list is available at:/find/contactusAmericasCanada(877) 894 4414Brazil55 11 3351 7010Mexico001 800 254 2440United States(800) 829 4444Asia PaciicAustralia 1 800 629 485China800 810 0189Hong Kong800 938 693India 1 800 112 929Japan0120 (421) 345Korea080 769 0800Malaysia 1 800 888 848Singapore180****8100Taiwan0800 047 866Other AP Countries(65) 6375 8100Europe & Middle EastAustria0800 001122Belgium0800 58580Finland0800 523252France0805 980333Germany***********Ireland1800 832700Israel 1 809 343051Italy800 599100Luxembourg+32 800 58580Netherlands0800 0233200Russia8800 5009286Spain0800 000154Sweden0200 882255Switzerland0800 805353Opt. 1 (DE)Opt. 2 (FR)Opt. 3 (IT)United Kingdom0800 0260637For other unlisted countries:/find/contactus(BP-07-01-14)。
宽带毫米波微带天线的设计

宽带毫米波微带天线的设计周大利;周骏;杨驾鹏;沈亚【摘要】A wide band millimeter wave microstrip antenna was designed and tested. The central antenna patch was excited by a microstrip line via PCB and the central frequency was 45 GHz. Beside the central patch, another two patches were excited by coupling and resonated at around 45 GHz. Adjusting sizes of patches, three resonant frequencies composed a wide band. After testing, the bandwidth is 9 GHz, bandwidth ratio is 22%, which are coincident with simulation results. Further, the size relationship between patches was changed according principle of Yagi antenna, and the radiation direction was controlled.%设计并实现了一款宽带毫米波微带天线.天线由微带线通过PCB通孔激励中心贴片,中心贴片谐振于45 GHz.放置于中心贴片两侧的两个寄生贴片,通过耦合产生两个在45 GHz附近的谐振频率.适当调整贴片大小,三个谐振频率合成一个宽带.经测试,天线带宽9.9 GHz,带宽比达到22%,与仿真结果基本一致.在此基础上,利用八木天线原理,改变天线尺寸关系,实现了主波束辐射方向偏转控制.【期刊名称】《电子元件与材料》【年(卷),期】2018(037)002【总页数】4页(P55-58)【关键词】微带天线;宽带;背馈;毫米波;八木天线;PCB板【作者】周大利;周骏;杨驾鹏;沈亚【作者单位】南京电子器件研究所,江苏南京 210016;南京电子器件研究所,江苏南京 210016;南京电子器件研究所,江苏南京 210016;南京电子器件研究所,江苏南京 210016【正文语种】中文【中图分类】TN702微带天线在可集成方面具有突出优势:体积小、质量小、低剖面、容易做到与高速飞行器共形等,且电气性能多样(如双频、多极化等),尤其容易与有源器件、微波电路集成为一体化组件。
PNA微波网络分析仪

PNA微波网络分析仪PNA (Network Analyzer) 是一种用于微波信号分析的仪器。
它主要用于测量微波电路的传输性能、振荡特性、散射参数等,并用于设计和测试微波和射频电路。
测试表面是一个微波测试系统,由一根或多根微波导线组成。
这些微波导线被称为测试端口,用于与待测设备连接。
测试端口上的信号会进入待测设备,并测量其传输性能。
控制单元是一个计算机或内置处理器,用于控制测试表面和处理测量数据。
它可以通过用户界面(如键盘、显示器和鼠标)或远程控制(如网络)与用户进行交互。
控制单元还包括信号源和接收器,用于生成和接收微波信号。
1.散射参数测量:PNA可以测量微波电路的散射参数,如S参数和Y参数。
这些参数描述了微波信号在电路中的传输情况,包括反射损耗、传输损耗和幅度/相位响应等。
2.频率扫描:PNA可以对待测设备进行频率扫描,以确定其频率响应。
通过这种方式,可以获得待测设备在频率范围内的传输情况。
3.时间域分析:PNA可以通过时域分析功能,测量微波信号的脉冲响应和时延。
这对于测量微波设备的瞬态响应非常有用。
4.射频功率测量:PNA可以对微波信号的功率进行测量,以确定它们的输入功率和输出功率。
5.效果分析:PNA可以对待测设备的效果进行分析,以确定其工作情况和性能特点。
6.校准和校正:PNA支持多种校准和校正方法,以提高测量的准确性。
通过校准和校正,可以消除传输线和接头等器件对测量的影响。
总之,PNA微波网络分析仪是一种非常重要的工具,用于测量和分析微波和射频电路的性能。
它可以帮助工程师设计和优化微波电路,并确保其性能符合要求。
是德科技keysight n9320b射频频谱分析仪使用手册说明书技术指标,原安捷伦agilent
Keysight N9320BRF Spectrum Analyzer9 kHz to 3.0 GHzData SheetThe spectrum analyzer will meet itsspecifications when:It is within its calibration cycle It has been turned on at least 30 minutes. It has been stored at an ambient temperature within the allowed operating range for at least two hours before being turned on; if it has been stored previously at a temperaturerange inside the allowed storage range, but outside the allowed operating range.“Specifications” describe the performance of parameters covered by the productwarranty and apply to the full temperature range of 5 to 45 °C, unless otherwise noted.“Typical” values describe additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 80 percent of the units exhibit with a 95 percent confidence level over the temperature range 20 to 30 °C. Typical performance does not include measurement uncertainty.“Nominal” values indicate expected performance, or describe product performance that is useful in the application of the product, but are not covered by the product warranty.Definitions and ConditionsRange1 Hz to 1 MHz in 1-3-10 sequence—3 dB bandwidth1. Frequency reference uncertainty = Aging rate x period since adjustment + supply voltage stability + temperature stability.Frequency and Time SpecificationCenter frequency 50 MHz, RBW 1 kHz, VBW 1 kHz, amplitude scale log, span 100 kHz, sweep time coupled, peak detector, signal at reference level Preamp off ± 0.3 dB Reference level —10 dB, input attenuation 10 dB Preamp on ± 0.4 dB Reference level —30 dB, input attenuation 10 dBAmplitude SpecificationsAmplitude Specifications (continued) Frequency range 1 MHz to 3.0 GHz Gain18 dB nominalDynamic Range SpecificationsPreamp off, signal input —30 dBm, 0 dB RF attenuationSecond harmonic distortion10 to 200 MHz+30 dBm200 to 500 MHz+35 dBm500 MHz to 3 GHz+43 dBmPreamp off, signal input -30 dBm, 0 dB RF attenuationThird-order intermodulation (TOI)300 MHz to 3 GHz+10 dBm; +13 dBm nominalTracking Generator Specifications (Option TG3 required)Average total power 30 dBm (1 W)AC coupled0 VDC MAXOffset from CW signal10 kHz < —88 dBc/Hz < —90 dBc/Hz Fc = 1 GHz, RBW = 1 kHz, VBW = 10 Hz, and sample detector, log average, average times > 40100 kHz < —100 dBc/Hz < —102 dBc/Hz 1 MHz< —110 dBc/Hz < —112 dBc/Hz Residual FM≤ 100 Hz peak-to-peak in 100 ms1 kHz RBW, 1 kHz VBWDynamic Range Specifications (continued)Modulation Analysis SpecificationsSymbol rate range 1 to 100 kHFSK deviation range 1 to 400 kHzAccuracy± 4% nominal b ≥1 and b ≤ 4, b is the ratio of frequencydeviation to symbol rateDisplayed resolution0.01 HzInputs and OutputsOutput amplitude> 0 dBmConnector and impedance BNC-type female, 50 Ω10 MHz reference input Input amplitude—5 to +10 dBmFrequency lock range± 5 ppm of specified external reference inputfrequencyConnector and impedance BNC-type female, 50 ΩExternal trigger input Input amplitude 5 V TTL levelConnector and impedance BNC-type female, 10 kΩVGA output VGA analog RGB31.5 kHz horizontal, 60 Hz vertical sync rates,non-interlacedD-sub 15-pin female connector VGA compatible640 x 480 screen resolutionLAN TCP/IP interface10Base, RJ-45 connectorUSB interface (device) B plug, version 1.1GPIB interface IEEE-488 bus connector Optional G01 installedGeneralThe recommended calibration cycle is one year. Calibration services are available through Keysight Service CentersRelated Literature–Keysight N9320B RF Spectrum Analyzer, Brochure, literature number 5990-8118EN–Keysight N9320B RF Spectrum Analyzer, Configuration Guide, literature number 5990-8120ENmyKeysightA personalized view into the information most relevant to you.AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is anopen standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group.LAN eXtensions for Instruments puts the power of Ethernet and theWeb inside your test systems. Keysight is a founding member of the LXI consortium.PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system.Three-Year Warranty/find/ThreeYearWarrantyKeysight’s commitment to superior product quality and lower total costof ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide.Keysight Assurance Plans/find/AssurancePlansUp to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements./go/qualityKeysight Technologies, Inc.DEKRA Certified ISO 9001:2008Quality Management SystemKeysight Channel Partners/find/channelpartnersGet the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience./find/n9320b For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: /find/contactus AmericasCanada(877) 894 4414 Brazil55 11 3351 7010 Mexico001 800 254 2440 United States(800) 829 4444 Asia PacificAustralia 1 800 629 485 China800 810 0189 Hong Kong800 938 693 India 1 800 112 929 Japan0120 (421) 345 Korea080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan0800 047 866 Other AP Countries(65) 6375 8100 Europe & Middle EastAustria0800 001122 Belgium0800 58580 Finland0800 523252 France0805 980333 Germany0800 6270999 Ireland1800 832700 Israel 1 809 343051 Italy800 599100 Luxembourg+32 800 58580 Netherlands0800 0233200 Russia8800 5009286 Spain800 000154 Sweden0200 882255 Switzerland0800 805353Opt. 1 (DE)Opt. 2 (FR)Opt. 3 (IT) United Kingdom0800 0260637 For other unlisted countries:/find/contactus(BP-09-23-14)11 | Keysight | M9037A PXIe Embedded Controller - Data SheetThis information is subject to change without notice.© Keysight Technologies, 2011 - 2014Published in USA, December 11, 20145990-8119EN。
Keysight E5080A ENA矢量网络分析仪用户手册说明书
Keysight TechnologiesE5080A ENA Vector Network Analyzer - 9 kHz to 4.5/6.5/9 GHzThe Next-Generation ENAThe Keysight E5080A is the next-generation RF vector network analyzer (VNA), providing best-in-class performance, flexible functionality and advanced usability for testing antennas, filters, cables, balanced/differential components, amplifiers and mixers. With its intuitive, touch-based interface, the E5080A is designed to help users streamline their measurement flow and achieve better results in less time. This new instrument implements a converged platform that leverages the best attributes of the ENA and PNA families. The E5080A sets the new standard in RF component testing for both R&D and manufacturing environments. The E5080A offers comprehensive functionalities for measuring active and passive components such as amplifiers, mixers, filters, antennas, cables, and many more. It builds on the over 45-year legacy of excellence in network analysis and 75-year electronic test and measurement experience.Best-in-Class PerformanceWide dynamic range152 dB (typical, 3 Hz IFBW)Fast measurement speed 3 ms (401 points, uncorrected)Low trace noise0.0005 dBrms (typical, 10 kHz IFBW)High temperature stability0.005 dB/°C (typical)Wide source power range–90 to +15 dBm (spec)The E5080A provides wide dynamic range from 9 kHz. More than 10 dB better dynamic range than E5071C enables to measure high-blocking DUTs such as filters accurately and improve measurement speed using wider IF bandwidth (IFBW). The unparalleled measurement speed compared to competitor products maximizes the test throughput in production line.Extremely low trace noise helps minimize errors and associated test margin when measuring low-loss devices such as filter pass-bands.The E5080A is designed to have the minimum temperature drift against variation of environment temperature. The superior measurement stability helps high-volume manufacturers minimize calibration time and associated downtime.152 dBIntuitive and Flexible Operations with Modern User InterfaceThe E5080A integrates a high resolution display with a touch screen, which provides a crisp view and easy access to alldata and traces. This enhanced user interface allows intuitive operation and helps you set up complex measurements quickly.The E5080A is designed to help users streamline their measurement flow. Measurement flow proceeds from right to left: front panel keys, touch-activated softkeys with tabs, and touch-driven trace displays and windowsEasy access to frequently used functionsThe tabbed soft panel enables you to access the analyzer’s major functions within a few steps. Your frequently used softkeys can be registered to the Favorite menu. A long touch on the screen activates the Context Popup menus, and these present the most relevant choices without needing to access the softkeys. Direct access to essential features through the toolbarMeasurement traces, channels, and windows can be quickly added by pressing the icons on the toolbar. The list of icons is customizable depending on your preference.Flexible traces and windows layoutThe layout of traces and windows can be flexibly allocated with intuitive drag-and-drop operations. Or the layout can also be changed by using the softkeys that split or combine traces and windows in a single action.Magnifying the displayWith multi-touch or single-touch gestures, you can magnify thedisplayed area on the screen.Figure 3. Customizable toolbar menusFigure 2. Tabbed soft panel and popup menuFigure 5. Multi-touch magnificationFigure 4. Drag-and-drop for traces/windowsStreamline Your Measurements with Advanced UsabilityThe E5080A’s advanced usability simplifies the measurement setup tasks, and its flexible display capabilities give excellent visibility of the measurement data.Quick setups using dialog menus and Copy ChannelA variety of dialog menus assist you in making complex measurement setups easily. The quick start dialog gives the templates of display layouts for typical measurement applications, and the subsequent sweep setup dialog completes necessary stimulus settings in a single page. Moreover, once you have completed making the setup for one channel, you can copyit to other channels by using the copy channel function. This significantly reduces the time required for making multi-channel measurement setups.Tabbed SheetThe tabbed sheet function allows you to split the measurement display into multiple pages within a single instrument state. Complicated multi-channel measurement data can be easily observed by splitting the channels into the sheets. The active sheet can be switched not only with the touch or mouse operations but with the Prev/Next hardkeys on the front panel. This is useful for manufacturing applications such as the BTS filter tuning where the hardkey operation is preferred.Flexible marker capabilitiesYou can place up to 15 markers per trace. For better visibility,the locations of the marker lists are flexibly movable, and the number of decimal places can be changed as you like. In addition, a variety of marker search functions are available, including the single or multiple max/min/peak/target search, the bandwidth/notch search, and the gain compression search. Figure 7. Displaying four channel data using Tabbed Sheet Figure 6. Quick Start dialogsFigure 8. Up to 15 markers per traceThe E5080A combines the highest RF performance with powerful analysis capabilities that enables you to address a variety of applications and increase test efficiency.Powerful, fast and accurate automatic fixture removal (S96007A)Accurately removing the effects of the fixture is required to get a good measurement of the DUT. Automatic fixture removal adds a powerful application wizard to guide you throughcharacterizing a fixture and removing it from the measurement. Complicated modeling in EM simulation software or multiple calibration standards fabricated on board is no longer needed to characterize and remove a fixture.–Easiest way to remove fixture effects from non-coaxial device measurements–Extract fixture S-parameters from 2x thru or one-port measurements–Step-by-step wizard to characterize your fixture and remove it from your measurementsAccurate characterization of mixers and converters (S96082A)Frequency offset mode is available to set the E5080A’s source frequency independently from where the receivers are tuned for mixer measurements. Scaler mixer calibration (SMC) provides the most accurate conversion loss/gain measurements by combining two-port and power calibration. Vector mixer calibration (VMC) provides measurements of match, conversion loss/gain and group delay. Input and output mismatch correction reduces ripple and eliminates the need for attenuators.–Intuitive user interface –Frequency-offset sweep–Match-corrected conversion loss measurements–Controls external signal generators and power metersFast, accurate gain compression versus frequency measurements of amplifiers (S96086A)S96086A makes it easy to characterize compression over the DUT’s operating frequency range with extreme speed and ac-curacy, and with a simple setup. Instead of a linear power sweep with many points, the S96086A uses an adaptive algorithm to find the desired compression point at each frequency with just a few power measurements, thus significantly reducing test times. –Fast and convenient measurements with SMART Sweep–Complete amplifier with 2-dimensional (2D) sweeps, choice of sweep frequency per power, or sweep power per frequencyE5080A Innovative ApplicationsFigure 9. Automatically characterizing test fixtureFigure 10. Intuitive wizard for configuring mixer/frequency converter measurementsFigure 11. Gain compression analysis of amplifierPinFrequencyGainCompression pointIteration pointAdvanced Calibration ToolsCalibrating network analyzers is critical for high accuracy measurements. The E5080A supports all common calibration methods for coaxial DUTs, waveguide DUTs and DUTs in test fixtures, on printed circuit boards (PCB) and on wafers. Thebuilt-in capabilities include advanced calibration methods and a new “basic calibration” feature that can simplify the calibration processes.TRL/LRL/TRM/LRM calibration (Through, Reflect, Line, Match) for on PCB and on-wafer measurements.Unknown Thru (SOLR) calibration for non-insertable devices.Source Power Cal for amplifier measurements, and offers advanced techniques such as power cal using the analyzer’s receiverQuick SOLT (QSOLT) reduces the number of correction standards and calibration steps for multiple ports calibration.Electronic calibration (ECal) modules offer accurate calibration with simple one-connection operation.Basic CalThe E5080A offers a variety of calibration menus and you can choose an appropriate menu depending on the complexity of your calibration methods. The Basic Cal dialog is a very simple calibration UI providing all the calibration buttons in the same dialog page. This calibration menu is suitable for performing relatively simple calibrations such as the basic SOLT cal. Advanced calibration methodsCal WizardThe E5080A also offers wizard-type calibration menus for complicated calibrations. The Smart Cal guides all the operation steps of the calibrations with the wizard menu. This calibration menu is suitable for performing complicated calibrations suchas mixed-connector cal, and the combination of the SOLT cal and the source/receiver power cals. The Cal All is the advanced wizard function of the Smart Cal. This calibration menu guides the calibrations of multi-channel measurement setups at minimal steps.Cal Plane ManagerThe Cal Plane Manager allows you to characterize the adapters, test fixtures, or probes to the S2P data, and mathematically de-embed them for improving the measurement accuracy at the DUT planes. This function also provides the capabilities for modifying the existing S2P files, such as reversing the port order of the S2P file and cascading two S2P files.Fixture simulatorThe fixture simulator offers functions for simulating fixtures and adapters such as embedding/deembedding, port matching, impedance transformation and port extensions.Figure 12. Basic CalFigure 13. Fixture simulatorExtend the Power of the E5080A ENA Measurements with up to 40 portsThe combination of the 4-port E5080A and E5092A configurable multiport test set offers a comprehensive multiport solution. Depending on your test requirements, you can flexibly build the test port configurations by changing the front jumper connections of up to two E5092A test sets. The measurement wizard assistant software (S93790A) simplifies complicated setup and calibration processes for multiport device tests with the E5080A and E5092A.CalPod calibration-refresh modulesKeysight provides a unique way to quickly and easily refresh a calibration at the push of a button, without removing the DUT, and without the physical connection of standards. CalPods are particularly useful in thermal or thermal-vacuum chambers for removing environmental effects from your measurement results due to temperature changes of cables, connectors, and adaptors, or for removing variations due to cable movements or variations in switch matrices.BenchVue SoftwareKeysight BenchVue software for the PC eliminates many of the issues around bench testing. By making it simple to connect, control instruments, and automate test sequences so you can quickly move past the test development phase and access results faster than ever before with just a few clicks. A dedicated Network Analyzer App, available with BV9001B, allows you to quickly configure the most commonly used measurements and setups. Rapidly build custom test sequences with the integrated Test Flow App to automate and visualize test results without the need for instrument programming. BenchVue supports hundreds of Keysight instrument types and models all from one easy to use software platform. Control, Automate, Simplify with BenchVue.–Easily control, get screen captures and trace data–Capture measurements from your network analyzer in asingle click–Automate common network analyzer controls andmeasurements as quickly as using your front panelFigure 14. Multiport configuration with E5080A and E5092AFigure 15. CalPods refresh a calibration without removing your DUT Figure 16. BenchVue: PC control, capture screen images or trace data, andbuild automated tests in minutesFigure 18. The E5080A’s state file converter helps you easilytransfer your tests with the E5071CFigure 17. Code emulation mode for legacy vector network analyzersCompatibilityThe E5080A shares a common software platform with all members of the latest PNA family that makes it easy to choose just the right level of performance to match your budget and measurement needs. This commonality guarantees measurement consistency and repeatability and a common remote-programming interface across multiple instruments in R&D and manufacturing.The E5080A offers the E5071C code emulation mode which interprets the SCPI commands of the E5071C. This allows for instrument emulation and backward code capability enabling a seamless drop-in replacement in your automated test environment and minimizing transition risks. State files created using the E5071C can be converted and recalled with the E5080A. The E5080A also supports the code emulation mode for the legacy 8753 series network analyzers.This compatibility means that you can easily make the transition to the E5080A while leveraging your investment and expertise in test software. The test software from R&D can be effortlessly transferred to manufacturing which helps you maintain past efforts, enhance current designs, and accelerate future innovations.Extend the Power of the E5080A ENA (continued)E5080A Front and Rear PanelsFlexible, modern user interface: front panel keys tabbed soft panel, pulldown menus, customizable toolbar, right-click shortcuts, drag-and-drop operation and 12.1’’ touch screenState-of-the-art calibration capabilitiesContext sensitive built-in help10 MHz reference Quick access for Ecal and other USB devicesUp to 15 markers per trace GPIB for remote operation Aux inputs for DC measurements200 measurementchannels and unlimited traces Sweep Setup and Quick Start enables easy setupUndo/Redo cancels or restores the previous entriesHandler I/O for external device controlLAN and device-side USB provide alternatives to GPIB for remote programmingRemovable solid-state drive for secure envi-ronments (optional)Maintain data securityThe removable solid-statedrive makes it easy to move the instrument from one location to another.E5080A Key Specs & Features (Comparison with E5071C)100 kHz to 4.5/6.5/8.5 GHz, with bias-tees Test port 2 or 4-port, 50 Ω 2 or 4-port, 50 ΩDynamic range(at max source power)135 dB (spec, 10 Hz IFBW)152 dB (typical, 3 Hz IFBW)123 dB (spec)Trace noise0.0015 dBrms (spec, 10 kHz IFBW)0.0005 dBrms (typical, 10 kHz IFBW)0.003 dBrms (spec, 70 kHz IFBW) Stability0.005 dB/°C (typical)0.005 dB/°C (typical) Measurement speed(401 pts, 200 MHz span, uncorrected)3 ms7 msSource power–90 to +15 dBm (spec)–110 to +17 dBm (typical)–55 to +10 dBm (spec)NOP Max 100,001Max 20,001Channels200160Markers15/trace9/traceMeasurement parameters S-parameters (single-ended, mixed-mode), Absolutepower S-parameters (single-ended, mixed-mode), Absolute power, TDR and TDT parameters1Software capabilities Automatic fixture removal, time-domain analysis,frequency offset mode, scalar & vector mixer/converter measurement, gain compression measure-ments, measurement wizard assistant Time-domain analysis, frequency offset mode, scalar & vector mixer/converter measurement, measurement wizard assistant, enhanced time-domain analysisOther major software capabilities Fixture simulator, Equation editor, PMAR (powermeter as receiver)Fixture simulator, Equation editor, External test set mode2Automation Remote control with SCPI commands, 8753/E5071C-code emulation, BenchVue Remote control with SCPI commands, Built-in VBA 8753 code emulation, BenchVueMultiport test set E5092A E5092A, E5091A3Display12.1 inch10.4 inchBox height6U5UOther major hardware capabilities High stability oven (option), Bias tees, DC input ports High stability oven (option), Bias tees, DC inputports, Probe power1. Optional capabilities2. Assigns 4 test ports as direct source/receiver ports, S, R, A, and B.3. Discontinued test set, Dec. 2014 EOS.For more detailed information, refer to E5080A Data Sheet.LiteratureE5080A EVector Network Analyzer ENA Series, Data Sheet, 5992-0291ENE5080A Vector Network Analyzer ENA Series, Configuration Guide, 5992-0292ENKeysight Technologies Network Analyzer Selection Guide, 5989-7603ENWeb Resources/find/ecal/find/mta/find/multiport/find/benchvue11 | Keysight | E5080A Vector Network Analyzer ENA Series - Data SheetThis information is subject to change without notice.© Keysight Technologies, 2016, 2017Published in USA, July 12, 20175992-0290ENFor more information on KeysightTechnologies’ products, applications or services, please contact your local Keysight office. The complete list is available at:/find/contactus Americas Canada (877) 894 4414Brazil 55 11 3351 7010Mexico001 800 254 2440United States (800) 829 4444Asia Pacific Australia 1 800 629 485China800 810 0189Hong Kong 800 938 693India 1 800 11 2626Japan 0120 (421) 345Korea 080 769 0800Malaysia 1 800 888 848Singapore 180****8100Taiwan0800 047 866Other AP Countries (65) 6375 8100Europe & Middle East Austria 0800 001122Belgium 0800 58580Finland 0800 523252France 0805 980333Germany ***********Ireland 1800 832700Israel 1 809 343051Italy800 599100Luxembourg +32 800 58580Netherlands 0800 0233200Russia 8800 5009286Spain 800 000154Sweden 0200 882255Switzerland0800 805353Opt. 1 (DE)Opt. 2 (FR)Opt. 3 (IT)United Kingdom0800 0260637For other unlisted countries:/find/contactus(BP-6-20-17)/go/quality Keysight Technologies, Inc.DEKRA Certified ISO 9001:2015Quality Management SystemEvolving Since 1939Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology.From Hewlett-Packard to Agilent to Keysight.myKeysight/find/mykeysightA personalized view into the information most relevant to you.Keysight Services/find/serviceKeysight Services can help from acquisition to renewal across your instrument’s lifecycle. Our comprehensive service offerings—one-stop calibration, repair, asset management, technology refresh, consulting, training and more—helps you improve product quality and lower costs.Three-Year Warranty/find/ThreeYearWarrantyKeysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company withthree-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products.Keysight Assurance Plans/find/AssurancePlansUp to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements.Keysight Channel Partners/find/channelpartnersGet the best of both worlds: Keysight’s measurement expertise and productbreadth, combined with channel partner convenience.。
安捷伦公司PNA微波网络分析仪的内嵌本振测量功能为射频和微波测量树立新的行业标准
安捷伦公司PNA微波网络分析仪的内嵌本振测量功能为射频
和微波测量树立新的行业标准
佚名
【期刊名称】《国外电子测量技术》
【年(卷),期】2007(26)10
【摘要】安捷伦科技有限公司日前宣布业界广受欢迎的PNA微波系列网络分析仪新增了内嵌本振测量功能。
通过这个新增的功能,PNA网络分析仪不用外接参考信号就能精确地测量变频器件,这个新功能为从事无线和卫星通信领域的射频微波测量工程师树立了新的标准。
【总页数】1页(P35-35)
【关键词】微波网络分析仪;微波测量;行业标准;测量功能;PNA;安捷伦公司;射频;本振
【正文语种】中文
【中图分类】TN92
【相关文献】
1.安捷伦网络分析仪的新测量功能可改变确定混频器特性的方式——新型矢量网络分析仪将PNA系列的性能延伸到67GHz,扩展了Agilent ECal系统的频率范围[J],
2.安捷伦公司PNA微波网络分析仪的内嵌本振测量功能为射频和微波测量树立新的行业标准 [J],
3.安捷伦高性能噪声系数测量技术的应用范围扩展至50 GHZ适用于PNA-X网络
分析仪的独特信号源调谐方法可提供业界领先的精度 [J],
4.安捷伦公司PNA微波网络分析仪的内嵌本振测量功能为射频和微波测量树立新的行业标准 [J],
5.PNA微波网络分析仪的内嵌本振测量功能为射频和微波测量树立新的行业标准[J],
因版权原因,仅展示原文概要,查看原文内容请购买。
Keysight EXA X-Series Signal Analyzer 数据手册说明书
N9010AK-1CM N9010AK-DVR N9010AK-EA3KeysightEXA X-Series Signal AnalyzerN9010A10 Hz to 3.6, 7.0, 13.6, 26.5, 32, or 44 GHzData SheetThis data sheet is a summary of the specifications and conditions for EXA signal analyzers. For the complete specifications guide, visit: /find/exa_specifications Balance the Challenges Whether you’re focused on time-to-market, time-to-volume, or cost of test, your choice of economy class signal analyzer should help you save both time and money. That’s the idea that drives the Keysight EXA signal analyzer—and it’s the fastest way to maximize throughputon the production line. From measurement speed to code compatibility, it makes every millisecond count and helps reduce your overall cost of test.Table of ContentsDefinitions and Conditions (3)Frequency and Time Specifications (4)Amplitude Accuracy and Range Specifications (6)Dynamic Range Specifications (9)PowerSuite Measurement Specifications (16)General Specifications (17)Inputs and Outputs (18)I/Q Analyzer (20)Related Literature (21)Get More InformationThis EXA signal analyzer data sheet is a summary of thespecifications and conditions for N9010A EXA signal analyzers, which are available in the EXA Signal Analyzer Specification Guide (N9010-90025).For ordering information, refer to the EXA Signal Analyzer Configuration Guide (5989-6531EN).Definitions and ConditionsSpecifications describe the performance of parameters covered by the product warranty and apply to the full temperature range of 0 to 55 °C 1, unless otherwise noted.95th percentile values indicate the breadth of the population (approx. 2 σ) of perfor-mance tolerances expected to be met in 95 percent of the cases with a 95 percent confidence, for any ambient temperature in the range of 20 to 30 °C. In addition to the statistical observations of a sample of instruments, these values include the effects of the uncertainties of external calibration references. These values are not warranted. These values are updated occasionally if a significant change in the statistically observed behavior of production instruments is observed.Typical describes additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 80 percent of the units exhibit with a 95 percent confidence level over the temperature range 20 to 30 °C. Typical performance does not include measurement uncertainty. Nominal values indicate expected performance, or describe product performance that is useful in the application of the product, but are not covered by the product warranty.The analyzer will meet its specifications when: –It is within its calibration cycle–Under auto couple control, except when Auto Sweep Time Rules = Accy –Signal frequencies < 10 MHz, with DC coupling applied–The analyzer has been stored at an ambient temperature within the allowed operating range for at least two hours before being turned on; if it had previously been stored at a temperature range inside the allowed storage range, but outside the allowed operating range –The analyzer has been turned on at least 30 minutes with Auto Align set to normal, or, if Auto Align is set to off or partial, alignments must have been run recently enough to prevent an Alert message; if the Alert condition is changed from Time and Temperature to one of the disabled duration choices, the analyzer may fail to meet specifications without informing the user For the complete specifications guide, visit:/find/exa_specifications1. For earlier instruments (Serial number prefix < MY/SG/US5052), the full temperature ranges from 5 to 50 °C.Frequency and Time SpecificationsRange0 Hz (zero span), 10 Hz to maximum frequency of instrument Resolution 2 HzAccuracy Swept FFT ± (0.25 % x span + horizontal resolution)± (0.10 % x span + horizontal resolution)1. When used with external frequency reference 1 pulse-per-second (PPS), such as the J7203A atomic frequency reference (AFR), the reference track-ing accuracy needs to be taken into account for calculation of the overall frequency accuracy. Refer to the EXA signal analyzer specifications guide (part number: N9010-90025) for more details.rate6 ms (167/s) 5 ms (200/s)Remote measurement and LAN transferrateMarker peak search 5 ms 1.5 msCenter frequency tune and transfer (RF)22 ms20 msCenter frequency tune and transfer (μW)49 ms47 msMeasurement/mode switching75 ms39 ms1. Analysis bandwidth is the instantaneous bandwidth available around a center frequency over which the input signal can be digitized for furtheranalysis or processing in the time, frequency, or modulation domain.2. Sweep points = 101.Amplitude Accuracy and Range Specifications0.1 to 1 dB/division in 0.1 dB steps1 to 20 dB/division in 1 dB steps (10 display divisions) Linear scale10 divisionsScale units dBm, dBmV, dBμV, dBmA, dBμA, V, W, A(Option 532, 544) 3.5 to 8.4 GHz± 0.67 dB nominal8.4 to 26.5 GHz± 0.80 dB nominal26.4 to 44 GHz± 0.80 dB nominal1. DC coupling required to meet specifications below 50 MHz. With AC coupling, specifications apply at frequencies of 50 MHz and higher. Statisticalobservations at 10 MHz with AC coupling show that most instruments meet the DC-coupled specifications, however, a small percentage of instruments are expected to have errors exceeding 0.5 dB at 10 MHz at the temperature extreme. The effect at 20 to 50 MHz is negligible but notwarranted.Option P03100 kHz to 3.6 GHzOption P07100 kHz to 7 GHzOption P13100 kHz to 13.6 GHzOption P26100 kHz to 26.5 GHzOption P32100 kHz to 32 GHzOption P44100 kHz to 44 GHzGain100 kHz to 3.6 GHz+20 dB nominal3.6 to 7.0 GHz+35 dB nominal> 7 GHz+40 dB nominalNoise figure100 kHz to 3.6 GHz8 to 12 dB nominal (proportional to frequency)3.6 to 8.4 GHz9 dB nominal8.4 to 13.6 GHz10 dB nominal> 13.6 GHz DANL + 176.24 dB nominalDynamic Range Specifications(Option 503, 507, 513, 526)10 MHz to 2.1 GHz–148 dBm–150 dBm2.1 to3.6 GHz–147 dBm–149 dBm3.6 to 7.0 GHz–147 dBm–149 dBm7.0 to 13.6 GHz–143 dBm–147 dBm13.6 to 17.1 GHz–137 dBm–142 dBm17.1 to 22 GHz–137 dBm–142 dBm22 to 26.5 GHz–134 dBm–140 dBmPreamp on, RF/MW (Option 503, 507, 513, 526)10 MHz to 2.1 GHz–161 dBm –163 dBm2.1 to3.6 GHz–160 dBm–162 dBm3.6 to 7.0 GHz–160 dBm–162 dBm 7.0 to 13.6 GHz– 160 dBm–163 dBm 13.5 to 17.1 GHz–157 dBm–160 dBm 17.0 to 20.0 GHz–155 dBm–159 dBm 20.0 to 26.5 GHz–150 dBm–156 dBmMillimeter-wave (Option 532, 544)9 kHz to 1 MHz ––130 dBm 1 MHz to 1.2 GHz–152 dBm–155 dBm1.2 to2.1 GHz–151 dBm–154 dBm2.1 to3.6 GHz–149 dBm–152 dBm3.5 to4.2 GHz –144 dBm–147 dBm4.2 to 8.4 GHz–145 dBm–150 dBm 8.3 to 13.6 GHz–147 dBm–150 dBm 13.5 to 20 GHz –145 dBm–148 dBm 20 to 26.5 GHz –142 dBm–145 dBm 26.4 to 34 GHz –140 dBm–144 dBm 34.4 to 44 GHz –135 dBm–140 dBmMid-Band 0 (1.8 GHz)–157 dBm–169 dBmMid-Band 1 (5.9 GHz)–152 dBm–166 dBmMid-Band 2 (10.95 GHz)–154 dBm–165 dBmMid-Band 3 (15.3 GHz)–153 dBm–164 dBmMid-Band 4 (21.75 GHz)–148 dBm–164 dBmMid-Band 5 (30.4 GHz)–145 dBm–160 dBmMid-Band 6 (42.7 GHz)–142 dBm–154 dBm1. When Option B40, DP2, or MPB is installed some aspects of the analyzer performance change. Please refer to the EXA specifications guide for moredetails.Spurious responsesResidual responses (input terminated and 0 dB attenuation)200 kHz to 8.4 GHz (swept) –100 dBm Zero span or FFT or other –100 dBm nominalFirst RF order(f ≥ 10 MHz from carrier)–10 dBm–80 dBc + 20log(N 1) Including IF feedthrough, LO harmonic mixingresponsesHigher RF order(f ≥ 10 MHz from carrier)–40 dBm–80 dBc + 20log(N 1) Including higher order mixer responsesCarrier frequency > 26.5 GHzFirst RF order(f ≥ 10 MHz from carrier)–30 dBm–90 dBc nominalHigher RF order(f ≥ 10 MHz from carrier)–30 dBm–90 dBc nominal 1. N is the LO multiplication factor.(Option 503, 507, 513, 526)100 to 400 MHz+13 dBm+17 dBm 400 MHz to 3.6 GHz+14 dBm+18 dBm 3.6 to 13.6 GHz+14 dBm+18 dBm 13.6 to 26.5 GHz+12 dBm+16 dBmPreamp on, RF/MW (Option 503, 507, 513, 526)30 MHz to 3.6 GHz (two –45 dBm tones at preamp)3.6 to 26.5 GHz (two –50 dBm tones at preamp)0 dBm nominal–18 dBm nominalMillimeter-wave (Option 532, 544)10 to 100 MHz+12 dBm+17 dBm100 MHz to 3.95 GHz+15 dBm+19 dBm3.95 to 8.4 GHz+15 dBm+18 dBm8.3 to 13.6 GHz +15 dBm+18 dBm13.5 to 17.1 GHz+11 dBm+17 dBm17.0 to 26.5 GHz +10 dBm+17 dBm (nominal) 26.5 to 44 GHz –+13 dBm (nominal)Preamp on, millimeter-wave (Option 532, 544)30 MHz to 3.6 GHz (two –45 dBm tones at preamp) 0 dBm (nominal) 3.6 to 26.5 GHz (two –50 dBm tones at preamp)–18 dBm (nominal)Nominal dynamic range for Options 503, 507, 513 and 526Figure 1. Nominal dynamic range – Band 0, for second and third order distortion, 9 kHz to 3.6 GHzFigure 2. Nominal dynamic range – Bands 1 to 4, for second and third order distortion,3.6 GHz to 26.5 GHzPhase noise 1Offset Specification Typical RF/MW(Option 503, 507, 513, 526)Noise sidebands(20 to 30 °C, CF = 1 GHz)100 Hz –84 dBc/Hz –88 dBc/Hz 1 kHz ––98 dBc/Hz nominal 10 kHz –103 dBc/Hz –105 dBc/Hz 100 kHz –115 dBc/Hz –117 dBc/Hz 1 MHz –135 dBc/Hz –137 dBc/Hz 10 MHz––148 dBc/Hz nominal1. Apply for all the RF/MW instruments with Serial number prefix ≥ MY/SG/US5340. Those instruments ship standard with N9010A-EP3 as theidentifier. For nominal phase noise values with the RF/MW EXA at other center frequencies refer to Figure 3. For earlier instruments refer to the EXA specifications guide.Figure 3. Nominal phase noise at different center frequencies for RF/MW EXA (Option 503, 507, 513, or 526) with SN prefix >/= MY/SG/US5340 that ships standard with N9010A-EP3.Nominal phase noise at different center frequencies for RF/μW EXA with RBW selectivity curves, optimized phase noise versus offset frequencyFigure 4. Nominal phase noise at different center frequencies for millimeter-wave EXA (Option 532 or 544)Phase noise 1Offset Specification TypicalMillimeter-wave 100 Hz –84 dBc/Hz –88 dBc/Hz(Option 532, 544) 1 kHz ––101 dBc/Hz nominal Noise sidebands10 kHz –103 dBc/Hz –106 dBc/Hz (20 to 30 °C, CF = 1 GHz)100 kHz –115 dBc/Hz –116 dBc/Hz 1 MHz –135 dBc/Hz –137 dBc/Hz10 MHz––149 dBc/Hz nominal1. For nominal phase noise values with the millimeter-wave EXA (Option 532 or 544), refer to Figure 4.Nominal phase noise at different center frequencieswith RBW selectivity curves, optimized phase noise versus offset frequencyS S B p h a s e n o i s e (d B c /H z )Freq (kHz)Option MPB, microwave preselector bypass 1Frequency range N9010A-507 3.6 to 7 GHz N9010A-513 3.6 to 13.6 GHz N9010A-526 3.6 to 26.5 GHz N9010A-532 3.6 to 32 GHz N9010A-5443.6 to 44 GHz1. When Option MPB is installed and enabled, some aspects of the analyzer performance changes. Please refer to the EXA specification guide for more details.PowerSuite Measurement SpecificationsRelative dynamic range (30 kHz RBW) Absolute sensitivityRelative accuracy 74.0 dB81.0 dB typical–94.7 dBm–100.7 dBm typical ± 0.11 dB3GPP W-CDMA (2.515 MHz offset)Relative dynamic range (30 kHz RBW) Absolute sensitivityRelative accuracy 76.5 dB83.9 dB typical–94.7 dBm–100.7 dBm typical ± 0.12 dBGeneral SpecificationsThe EXA signal analyzer is supplied with a standard 3-year warrantyCalibration cycleThe recommended calibration cycle is two years; calibration services are available through Keysight service centersInputs and OutputsConnectorOutput amplitude Frequency BNC female, 50 Ω nominal≥ 0 dBm nominal10 MHz ± (10 MHz x frequency reference accuracy)Ext Ref InConnectorInput amplitude range Input frequencyFrequency lock range BNC female, 50 Ω nominal–5 to 10 dBm nominal10 MHz nominal± 5 x 10–6 of specified external reference input frequencyTrigger 1 and 2 inputs ConnectorImpedanceTrigger level range BNC female> 10 kΩ nominal –5 to 5 VTrigger 1 and 2 outputs ConnectorImpedanceLevel BNC female 50 Ω nominal 5 V TTL nominalMonitor output Connector FormatResolution VGA compatible, 15-pin mini D-SUBXGA (60 Hz vertical sync rates, non-interlaced) analog RGB 1024 x 768RangeResolution 10 to 75 MHz (user selectable) 0.5 MHzConversion gain–1 to +4 dB (nominal) plus RF frequency response BandwidthOutput at 70 MHz centerLow band or high band with preselector bypassed 1100 MHz (nominal)Preselected band Depends on RF center frequencyLower output frequencies Subject to foldingResidual output signals≤ –88 dBm (nominal)1. Option MPB installed and enabled.I/Q AnalyzerFrequencyFrequency spanStandard10 Hz to 10 MHzOption B25 (standard)10 Hz to 25 MHz10 Hz to 40 MHz0.02 ≤ f < 3.6≤ 25n/a0.6°0.14°≥ 3.6≤ 25off 1 1.9° 0.4° ≥ 3.6 (Option ≤ 526)≤ 25on 4.5° 1.2°1. Option MPB is installed and enabled.20Length (IQ sample pairs)536 MSa268 MSaLength (time units)Samples/(span x 1.28) (nominal) Sample rateAt ADC200 MSa/sIQ pairs Span x 1.28 (nominal)ADC resolution12 bits1. Option MPB is installed and enabled.Related LiteraturePublication title Publication numberEXA X-Series Signal Analyzer N9010A – Brochure5989-6527ENN9010A EXA X-Series Signal Analyzer – Configuration Guide5989-6531ENFor more information or literature resources please visit the web:Product page: /find/N9010AX-Series measurement applications: /find/X-Series_AppsX-Series signal analyzers: /find/X-Series21myKeysight/find/mykeysightA personalized view into the information most relevant to you.LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium.Three-Year Warranty/find/ThreeYearWarrantyKeysight’s commitment to superior product quality and lower total costof ownership. The only test and measurement company with three-yearwarranty standard on all instruments, worldwide.Keysight Assurance Plans/find/AssurancePlansUp to five years of protection and no budgetary surprises to ensure yourinstruments are operating to specification so you can rely on accuratemeasurements./qualityKeysight Technologies, Inc.DEKRA Certified ISO 9001:2008Quality Management SystemKeysight Channel Partners/find/channelpartnersGet the best of both worlds: Keysight’s measurement expertise and productbreadth, combined with channel partner convenience.cdma2000® is a registered certification mark of the Telecommunications IndustryAssociation. Used under license./find/exaFor more information on KeysightTechnologies’ products, applications orservices, please contact your local Keysightoffice. The complete list is available at:/find/contactusAmericasCanada(877) 894 4414Brazil55 11 3351 7010Mexico001 800 254 2440United States(800) 829 4444Asia PacificAustralia 1 800 629 485China800 810 0189Hong Kong800 938 693India 1 800 112 929Japan0120 (421) 345Korea080 769 0800Malaysia 1 800 888 848Singapore180****8100Taiwan0800 047 866Other AP Countries(65) 6375 8100Europe & Middle EastAustria0800 001122Belgium0800 58580Finland0800 523252France0805 980333Germany***********Ireland1800 832700Israel 1 809 343051Italy800 599100Luxembourg+32 800 58580Netherlands0800 0233200Russia8800 5009286Spain0800 000154Sweden0200 882255Switzerland0800 805353Opt. 1 (DE)Opt. 2 (FR)Opt. 3 (IT)United Kingdom0800 0260637For other unlisted countries:/find/contactus(BP-07-10-14)22 | Keysight | N9010A EXA X-Series Signal Analyzer - Data SheetThis information is subject to change without notice.© Keysight Technologies, 2013 – 2014Published in USA, August 29, 20145989-6529ENN9010AK-1CM N9010AK-DVR N9010AK-EA3。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Data Sheet and Technical SpecificationsKeysight 2-Port and 4-Port PNA Network AnalyzerN5224A 10 MHz to 43.5 GHz N5225A 10 MHz to 50 GHzDocumentation WarrantyTHE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED "AS IS," AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL.U.S. Government RightsU.S. Government Rights. The Software is “commercial computer software,” as defined by Federal Acquisit ion Regulation (“FAR”) 2.101. Pursuant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supplement (“DFARS”) 227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at /find/sweula. The license set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, display, or disclose commercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR 27.401 or DFAR 227.7103-5 (c), as applicable in any technical data.Corrected System Performance (6)System Dynamic Range and Receiver Dynamic Range (6)Table 1a. System Dynamic Range and Receiver Dynamic Range, N5224A, Option 200, 400 (7)Table 1b. System Dynamic Range and Receiver Dynamic Range, N5225A, Option 200, 400 (8)Table 2. System Dynamic Range at Test Port (dB) (9)Table 3. Extended Dynamic Range at Direct Receiver Access Input (dB) - Specification (10)N5224A and N5225A Corrected System Performance, All Options (11)Table 4a. N5224A and N5225A with 85056A Calibration Kit (11)Table 4b. N5224A and N5225A with N4693A 2-Port Electronic Calibration Module (13)Uncorrected System Performance (16)Table 5a. Error Terms (dB), All Ports, All Options - Specifications (16)Table 5b. Error Terms (dB), All Ports, All Options - Typical (17)Test Port Output (18)Table 6. Frequency Information, All Options (18)Table 7a. Maximum Leveled Power (dBm), All Ports - Specification (18)Table 7b. Maximum Leveled Power (dBm), All Ports - Typical (19)Table 8. Power Level Accuracy (dB) at Nominal Power1, All Options (19)Table 9a. Power Level Linearity1 (dB), All Options - Specification (20)Table 9b. Power Level Linearity1 (dB), All Options - Specification (20)Table 10a. Power Sweep Range (dB), All Ports - Specification (20)Table 10b. N5224 and N5225A Power Sweep Range (dB), All Ports - Typical (21)Table 11. Nominal (Preset) Power (dBm) (21)Table 12. Power Resolution and Maximum/Minimum Settable Power, All Models and Options21 Table 13. 2nd and 3rd Harmonics at Max Specified Power (dBc) All Options - Typical (22)Table 14. Non-Harmonic Spurs at Nominal Power (dBc), All Models and Options - Typical (22)Table 15. Phase Noise (dBc/Hz), All Options - Typical (23)Test Port Input (23)Table 16. Test Port Noise Floor (dBm) @ 10 Hz IFBW, All Options (23)Table 17. Direct Receiver Access Input Noise Floor (dBm), Option 201, 217, 219, 401,417, 419 (24)Table 18a. 0.1 dB Receiver Compression at Test Port (dBm), Option 201, 217, 219, 401, 417, 419 - Typical (24)Table 18b. Receiver Compression at Test Power - Specification (25)Table 19. Trace Noise Magnitude (dB rms) (25)Table 20. Trace Noise Phase (deg rms) (26)Table 21. Reference Level Magnitude, All Models and Options - Specification (26)Table 22. Stability, All Options - Typical (27)Table 23. Damage Input Level, All ports (27)Dynamic Accuracy (27)Table 24. N5224A and N5225A Dynamic Accuracy (27)Table 25. Group Delay - Typical (31)General Information (32)Table 26. Miscellaneous Information (32)Table 27. Front Panel Information, All Options (32)Table 28. Rear Panel Information, All Options (33)Table 29. Analyzer Dimensions and Weight (37)Regulatory and Environmental Information (37)Measurement Throughput Summary (38)Table 30a. Typical Cycle Time (ms) for Measurement Completion, All Models and Options (38)Table 30b. N5224A Typical Cycle Time (ms) for Full-Span Measurement Completion (39)Table 30c. N5225A Typical Cycle Time (ms) for Full-Span Measurement Completion (39)Table 31. Cycle Time vs. IF Bandwidth - Typical (40)Table 32. Cycle Time vs. Number of Points - Typical (41)Table 33. Data Transfer Time (ms) - Typical (42)Specifications: Front-Panel Jumpers (43)Table 34. Measurement Receiver Inputs (dBm) - Typical (43)Table 35. Reference Receiver Inputs and Reference Source Outputs (dBm) - Typical (44)Table 36. Reference Receiver Inputs and Reference Receiver Outputs (dBm) - Typical (45)Table 37. Source Outputs (dBm) - Typical (46)Table 38. Coupler Inputs (dB) - Typical (47)Table 39. Damage Level - Typical (47)Test Set Block Diagrams (48)N5224A and N5225A Option 200 (2-port base model) (48)N5224A and N5225A Option 201 (48)N5224A and N5225A Option 217 (49)N5224A and N5225A Option 219 (49)N5224A and N5225A Option 400 (4-port base model) (50)N5224A and N5225A Option 401 (50)N5224A and N5225A Option 417 (51)N5224A and N5225A Option 419 (51)Receiver Block Diagram (52)This is a complete list of the technical specifications for the N5224A and N5225A PNA network analyzers with the following options. See block diagrams on page 46 for all models and options.2-Port ModelsOption 200 - 2-port base model with standard test set.Option 201 - To base model, adds front-panel jumpers and R1 receiver switch.Option 217 - To base model, adds front-panel jumpers, R1 receiver switch, and source and receiverattenuators (extended power range).Option 219 - To base model, adds front-panel jumpers, R1 receiver switch, source and receiver attenuators (extended power range), and bias-tees.4-Port ModelsOption 400 - 4-port base model with standard test set.Option 401 - To base model, adds front-panel jumpers and R1 receiver switch.Option 417 - To base model, adds front-panel jumpers, R1 receiver switch, and source and receiverattenuators (extended power range).Option 419 - To base model, adds front-panel jumpers, R1 receiver switch, source and receiver attenuators (extended power range), and bias-tees.NotesThis document provides technical specifications for the 85056A and N4693A calibration kits.Please download our free Uncertainty Calculator from /find/na_calculator to generate the curves for your calibration kit and PNA setup.For all tables in this data sheet, the specified performance at the exact frequency of a break is the degraded value of the two specifications at that frequency.DefinitionsAll specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument has been turned on.Specification (spec.): Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions.Characteristic (char.): A performance parameter that the product is expected to meet before it leaves the factory, but that is not verified in the field and is not covered by the product warranty. A characteristic includes the same guardbands as a specification.Typical (typ.): Expected performance of an average unit which does not include guardbands. It is not covered by the product warranty.Nominal (nom.): A general, descriptive term that does not imply a level of performance. It is not covered by the product warranty.Calibration: The process of measuring known standards to characterize a network analyzer's systematic (repeatable) errors.Corrected (residual): Indicates performance after error correction (calibration). It is determined by the quality of calibration standards and how well "known" they are, plus system repeatability, stability, and noise. Uncorrected (raw): Indicates instrument performance without error correction. The uncorrected performance affects the stability of a calibration.Standard: When referring to the analyzer, this includes no options unless noted otherwise.Corrected System PerformanceThe specifications in this section apply for measurements made with the N5224A and N5225A PNA network analyzers with the following conditions:▪10 Hz IF bandwidth▪No averaging applied to data▪Isolation calibration with an averaging factor of 8System Dynamic Range and Receiver Dynamic Range▪System Dynamic Range is defined as the specified source maximum output power (spec) minus the noise floor (spec).▪Extended Dynamic Range at Direct Access Input is defined as the specified source maximum output power (spec) minus the direct receiver access input noise floor (spec).▪Receiver Dynamic Range is defined as the test port compression at 0.1 dB (typical) minus the noise floor (typical).The effective dynamic range must take measurement uncertainties and interferingsignals into account. This set-up should only be used when the receiver input willnever exceed its maximum receiver input. When the analyzer is in segment sweepmode, it can have predefined frequency segments which will output a higher powerlevel when the extended dynamic range is required (i.e. devices with high insertionloss), and reduced power when the maximum receiver input level will occur (i.e.devices with low insertion loss). The extended range is only available in one-pathtransmission measurements.It may typically be degraded at particular frequencies below 500 MHz due to spuriousreceiver residuals.Description Specification TypicalSystem Dynamic Range (dB) (A)-(B) MaxLeveledOutputPower(dBm)(A)Test PortNoise Floor(dBm)(B)ReceiverDynamicRange (dB)(C)-(D)0.1 dBCompressionat Test Port(dBm)(C)Test PortNoise Floor(dBm)(D)10 MHz to 50 MHz 82 12 -70 90 15 -75 50 MHz to 100 MHz 98 13 -85 106 15 -91 100 MHz to 250 MHz 108 13 -95 112 12 -100 250 MHz to 500 MHz 115 13 -102 119 12 -107 500 MHz to 1 GHz 119 13 -106 124 12 -112 1 GHz to 10 GHz 127 13 -114 130 12 -118 10 GHz to 26.5 GHz 127 13 -114 132 12 -120 26.5 GHz to 35 GHz 123 13 -110 128 12 -116 35 GHz to 40 GHz 118 10 -108 128 12 -116 40 GHz to 43.5 GHz 118 10 -108 124 10 -114Description Specification TypicalSystem Dynamic Range (dB) (A)-(B) Max LeveledOutput Power(dBm)(A)Test PortNoise Floor(dBm)(B)ReceiverDynamicRange (dB)(C)-(D)0.1 dBCompressionat Test Port(dBm)(C)Test PortNoise Floor(dBm)(D)10 MHz to 50 MHz 82 12 -70 90 15 -75 50 MHz to 100 MHz 98 13 -85 106 15 -91 100 MHz to 250 MHz 108 13 -95 112 12 -100 250 MHz to 500 MHz 115 13 -102 119 12 -107 500 MHz to 1 GHz 119 13 -106 124 12 -112 1 GHz to 10 GHz 127 13 -114 130 12 -118 10 GHz to 26.5 GHz 127 13 -114 132 12 -120 26.5 GHz to 35 GHz 123 13 -110 128 12 -116 35 GHz to 40 GHz 118 10 -108 128 12 -116 40 GHz to 43.5 GHz 118 10 -108 124 10 -114 43.5 GHz to 47 GHz 115 6 -109 126 10 -116 47 GHz to 50 GHz 107 -2 -109 126 10 -116Table 2. System Dynamic Range at Test Port (dB)Description Specification TypicalOption 200,400 Option 201,401Option 217,219, 417,419Option 200,400Option 201,401Option 217,219, 417,41910 MHz to 50 MHz 82 82 80 93 93 93 50 MHz to 100 MHz 98 98 96 109 109 109 100 MHz to 250 MHz 108 108 106 118 118 118 250 MHz to 500 MHz 115 115 113 125 125 125 500 MHz to 1 GHz 119 118 117 130 130 1301 GHz to2 GHz 127 127 125 137 137 1372 GHz to 3.2 GHz 127 127 125 136 136 1353.2 GHz to 10 GHz 127 127 125 138 138 138 10 GHz to 13.5 GHz 127 127 125 138 138 137 13.5 GHz to 16 GHz 127 127 125 140 139 138 16 GHz to 20 GHz 127 127 124 138 138 137 20 GHz to 24 GHz 127 127 124 138 138 136 24 GHz to 26.5 GHz 127 127 124 138 137 135 26.5 GHz to 30 GHz 123 122 119 133 132 130 30 GHz to 32 GHz 123 121 117 134 133 130 32 GHz to 35 GHz 123 122 119 134 133 130 35 GHz to 43.5 GHz 118 117 112 129 128 125 43.5 GHz to 47 GHz 115 114 108 128 126 123 47 GHz to 50 GHz 107 104 98 124 121 120Table 3. Extended Dynamic Range at Direct Receiver Access Input (dB) - SpecificationDescription Option 201, 401 Option 217, 219, 417, 419 10 MHz to 50 MHz 117 11550 MHz to 100 MHz 118 116100 MHz to 250 MHz 120 118250 MHz to 500 MHz 127 125500 MHz to 1 GHz 130 1291 GHz to 10 GHz 139 13710 GHz to 20 GHz 139 13620 GHz to 26.5 GHz 137 13426.5 GHz to 30 GHz 132 12930 GHz to 32 GHz 131 12732 GHz to 35 GHz 132 12935 GHz to 40 GHz 127 12240 GHz to 43.5 GHz 125 12043.5 GHz to 47 GHz 122 11647 GHz to 50 GHz 112 106N5224A and N5225A Corrected System Performance, All OptionsFor any Sii reflection measurement:•Sjj = 0.For any Sij transmission measurement:•Sji = Sij when Sij ≤ 1•Sji = 1/Sij when Sij > 1•Skk = 0 for all kApplies to the N5224A/5A Option 200, 201, 217, 219, 400, 401, 417 or 419 analyzers, 85133F flexible test port cable set, and a full 2-port calibration. Also applies to the following condition:Environmental temperature 23° ±3 °C, with < 1 °C deviation from calibration temperatureTable 4a. N5224A and N5225A with 85056A Calibration KitDescription Specification (dB)10 MHz to 50 MHz 50 MHz to2 GHz2 GHzto10 GHz10 GHzto20 GHz20 GHzto30 GHz30 GHzto40 GHz40 GHzto50 GHzDirectivity 42 42 42 42 38 38 36Source Match 41 41 38 38 33 33 31 Load Match 42 42 42 42 37 37 35Reflection TrackingMag ±0.001 ±0.001 ±0.008 ±0.008 ±0.020 ±0.020 ±0.027 Phase (°) ±0.009 ±0.009 ±0.054 ±0.054 ±0.133 ±0.133 ±0.180Transmission TrackingMag ±0.045 ±0.020 ±0.036 ±0.051 ±0.123 ±0.123 ±0.162 Phase (°) ±0.300 ±0.135 ±0.236 ±0.337 ±0.811 ±0.811 ±1.068Table 4b. N5224A and N5225A with N4693A 2-Port Electronic Calibration Module Description Specification (dB)10 MHz to 50 MHz 50 MHz to2 GHz2 GHzto10 GHz10 GHz to20 GHz20 GHz to30 GHz30 GHz to40 GHz40 GHz to50 GHzDirectivity 32 42 49 45 41 41 36Source Match 25 44 42 37 35 35 32 Load Match 25 43 41 36 34 34 31Reflection TrackingMag ±0.050 ±0.030 ±0.040 ±0.050 ±0.060 ±0.060 ±0.080 Phase (°) ±0.330 ±0.198 ±0.264 ±0.330 ±0.396 ±0.396 ±0.528Transmission TrackingMag ±0.118 ±0.038 ±0.047 ±0.065 ±0.091 ±0.091 ±0.134 Phase (°) ±0.781 ±0.249 ±0.309 ±0.431 ±0.598 ±0.598 ±0.885Uncorrected System PerformanceSpecifications apply to following conditions:▪Cable loss not included in Transmission Tracking.▪Crosstalk measurement conditions: normalized to a thru, measured with shorts on all ports, 10 Hz IF bandwidth, averaging factor of 8, alternate mode, source power set to the specified maximum power. Table 5a. Error Terms (dB), All Ports, All Options - SpecificationsDescription Directivity SourceMatchLoad MatchTransmissionTrackingReflectionTrackingCrosstalk10 MHz to 50 MHz 18 10 10 -- -- -- 50 MHz to 200 MHz 22 21 19 -- -- -- 200 MHz to 500 MHz 24 21 18 -- -- -- 500 MHz to 3.2 GHz 25 18 16 -- -- -- 3.2 GHz to 10 GHz 22 16 13 -- -- -- 10 GHz to 13.5 GHz 18 13 11 -- -- -- 13.5 GHz to 20 GHz 18 13 1020 GHz to 26.5 GHz 16 12 10 -- -- -- 26.5 GHz to 43.5 GHz 16 8 8 -- -- -- 43.5 GHz to 50 GHz 15 7 8 -- -- --Table 5b. Error Terms (dB), All Ports, All Options - TypicalDescription Directivity SourceMatchLoad MatchTransmissionTrackingReflectionTrackingCrosstalk10 MHz to 50 MHz 21 15 15 +/- 1.0 +/- 0.7 -82 50 MHz to 200 MHz 28 31 26 +/- 1.0 +/- 0.7 -85 200 MHz to 500 MHz 33 29 24 +/- 1.0 +/- 0.7 -110 500 MHz to 3.2 GHz 30 25 20 +/- 1.0 +/- 0.7 -120 3.2 GHz to 10 GHz 25 22 17 +/- 1.0 +/- 0.7 -120 10 GHz to 13.5 GHz 23 21 15 +/- 1.0 +/- 0.7 -120 13.5 GHz to 16 GHz 20 20 14 +/- 1.0 +/- 0.7 -120 16 GHz to 20 GHz 19 18 16 +/- 1.0 +/- 0.7 -120 20 GHz to 24 GHz 20 17 14 +/- 1.0 +/- 0.7 -120 24 GHz to 26.5 GHz 21 17 15 +/- 1.0 +/- 0.7 -120 26.5 GHz to 35 GHz 19 15 13 +/- 1.0 +/- 0.7 -120 35 GHz to 43.5 GHz 19 15 13 +/- 1.0 +/- 0.7 -115 43.5 GHz to 46 GHz 19 14 14 +/- 1.0 +/- 0.7 -105 46 GHz to 50 GHz 19 13 13 +/- 1.0 +/- 0.7 -100Test Port OutputSee Block diagrams for all models and option beginning on page 45.Table 6. Frequency Information, All OptionsDescription Specification Typical N5224A Frequency Range 10 MHz to 43.5 GHz -- N5225A Frequency Range 10 MHz to 50 GHz -- Frequency Resolution 1 Hz -- Frequency Accuracy +/- 1 ppm --Frequency Stability -- +/-0.05 ppm, -10° to 70° C1 +/-0.1 ppm/yr maximum21 Assumes no variation in time.2 Assumes no variation in temperature.Table 7a. Maximum Leveled Power (dBm), All Ports - SpecificationDescription Option 200, 400 Option 201, 401 Option 217, 417, 219, 419 10 MHz to 50 MHz 12 12 1050 MHz to 16 GHz 13 13 1116 GHz to 26.5 GHz 13 13 1026.5 GHz to 30 GHz 13 12 930 GHz to 32 GHz 13 11 732 GHz to 35 GHz 13 12 935 GHz to 43.5 GHz 10 9 443.5 GHz to 47 GHz 6 5 -147 GHz to 50 GHz -2 -5 -11Table 7b. Maximum Leveled Power (dBm), All Ports - TypicalDescription Option 200, 400 Option 201, 401 Option 217, 417, 219, 419 10 MHz to 1 GHz 18 18 181 GHz to2 GHz 19 19 192 GHz to 3.2 GHz 18 18 173.2 GHz to 10 GHz 20 20 2010 GHz to 13.5 GHz 18 18 1713.5 GHz to 16 GHz 20 19 1816 GHz to 20 GHz 18 18 1720 GHz to 24 GHz 18 18 1624 GHz to 26.5 GHz 18 17 1526.5 GHz to 30 GHz 19 18 1630 GHz to 35 GHz 18 17 1435 GHz to 43.5 GHz 15 14 1143.5 GHz to 47 GHz 12 10 747 GHz to 50 GHz 8 5 4Table 8. Power Level Accuracy (dB) at Nominal Power1, All OptionsDescription Specification Typical10 MHz to 50 MHz +/- 1.5 +/- 0.550 MHz to 1 GHz +/- 1.0 +/- 0.41 GHz to 3.2 GHz +/- 1.2 +/- 0.13.2 GHz to 13.5 GHz +/- 1.5 +/- 0.313.5 GHz to 20 GHz +/- 1.5 +/- 0.220 GHz to 26.5 GHz +/- 1.8 +/- 0.226.5 GHz to 43.5 GHz +/- 2.2 +/- 0.343.5 GHz to 50 GHz +/- 3.2 +/- 0.51 Level accuracy at power other than nominal power, Power Level Accuracy (dB) at Nominal Power + Power Level Linearity (dB).Table 9a. Power Level Linearity1 (dB), All Options - SpecificationDescriptionPort 1 or 32-25dBm ≤ P<-20dBmPort 1 or 32-20dBm ≤ P<-15dBmPort 1 or 32P ≥-15dBm10 MHz to 50 MHz +/-2.5 +/-1.5 +/-1.5 50 MHz to 500 MHz +/-2.0 +/-1.5 +/-1.5 500 MHz to 50 GHz +/-1.5 +/-1.5 +/-1.51 Referenced to nominal power.2 Either port can be used as the source port.Table 9b. Power Level Linearity1 (dB), All Options - SpecificationDescriptionPort 2 or 42-25dBm ≤ P<-20dBmPort 2 or 42-20dBm ≤ P<-15dBmPort 2 or 42P ≥-15dBm10 MHz to 50 MHz +/-2.5 +/-1.5 +/-1.550 MHz to 3.2 GHz +/-2.0 +/-1.5 +/-1.53.2 GHz to 50 GHz +/-1.5 +/-1.5 +/-1.51 Referenced to nominal power.2 Either port can be used as the source port.Table 10a. Power Sweep Range (dB), All Ports - SpecificationDescription Option 200, 400 Option 201, 401 Option 217, 219, 417, 419 10 MHz to 50 MHz 37 37 3550 MHz to 16 GHz 38 38 3616 GHz to 26.5 GHz 38 38 3526.5 GHz to 30 GHz 38 37 3430 GHz to 32 GHz 38 36 3232 GHz to 35 GHz 38 37 3435 GHz to 43.5 GHz 35 34 2943.5 GHz to 47 GHz 31 30 2447 GHz to 50 GHz 23 20 14Table 10b. N5224 and N5225A Power Sweep Range (dB), All Ports - TypicalDescription Option 200, 400 Option 201, 401 Option 217, 219, 417, 419 10 MHz to 1 GHz 45 45 451 GHz to2 GHz 46 46 462 GHz to 3.2 GHz 45 45 443.2 GHz to 10 GHz 47 47 4710 GHz to 13.5 GHz 45 45 4413.5 GHz to 16 GHz 47 46 4516 GHz to 20 GHz 45 45 4420 GHz to 24 GHz 45 45 4324 GHz to 26.5 GHz 45 44 4226.5 GHz to 30 GHz 46 45 4330 GHz to 35 GHz 45 44 4135 GHz to 43.5 GHz 42 41 3843.5 GHz to 47 GHz 39 37 3447 GHz to 50 GHz 35 32 31Table 11. Nominal (Preset) Power (dBm)Description N5224A N5225AOption 200, 201, 400, 401 0 -5Option 217, 219, 417, 419 -5 -15Table 12. Power Resolution and Maximum/Minimum Settable Power, All Models and OptionsDescription Specification (dB) Typical (dBm)Power Resolution 0.01Maximum Settable Power -- 30Minimum Settable PowerOption 200, 201, 400, 401 Option 217, 219, 417, 419 -----30-90Table 13. 2nd and 3rd Harmonics at Max Specified Power (dBc) All Options - TypicalListed frequency is harmonic frequency; test at max specified powerDescription N5224A N5225A20 MHz to 4 GHz -15 -154 GHz to 6 GHz -18 -186 GHz to 24 GHz -19 -1924 GHz to 27 GHz -21 -2127 GHz to 40.5 GHz -29 -2940.5 GHz to 43.5 GHz -60 -6043.5 GHz to 50 GHz -- -60Table 14. Non-Harmonic Spurs at Nominal Power (dBc), All Models and Options - TypicalOffset frequency = 30 kHz to 5 MHzDescription Based on 8kHz offset Frac-N Based on 100kHz offset Frac-N 10 MHz to 500 MHz -50 -50500 MHz to 2 GHz -60 -422 GHz to 4 GHz -57 -454 GHz to 8 GHz -51 -398 GHz to 16 GHz -45 -3316 GHz to 32 GHz -39 -2732 GHz to 50 GHz -33 -21Table 15. Phase Noise (dBc/Hz), All Options - TypicalDescription 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz to 50 MHz -100 -95 -95 -120 50 MHz to 1 GHz -107 -117 -112 -1271 GHz to2 GHz -101 -111 -106 -1212 GHz to 4 GHz -95 -105 -100 -1154 GHz to 8 GHz -89 -99 -94 -1098 GHz to 16 GHz -83 -93 -88 -103 16 GHz to 32 GHz -77 -87 -82 -9732 GHz to 50 GHz -71 -81 -76 -91Test Port InputTable 16. Test Port Noise Floor (dBm) @ 10 Hz IFBW, All OptionsTotal average (rms) noise power calculated as the mean value of a linear magnitude trace expressed in dBm. May typically be degraded at particular frequencies below 500 MHz due to spurious receiver residuals.Description Specification TypicalN5224A N5225A N5224A N5225A 10 MHz to 50 MHz -70 -70 -75 -7550 MHz to 100 MHz -85 -85 -91 -91 100 MHz to 250 MHz -95 -95 -100 -100 250 MHz to 500 MHz -102 -102 -107 -107 500 MHz to 1 GHz -106 -106 -112 -1121 GHz to 10 GHz -114 -114 -118-11810 GHz to 26.5 GHz -114 -114 -120-120 26.5 GHz to 35 GHz -110 -110 -116-11635 GHz to 40 GHz -108 -108 -116 -11640 GHz to 43.5 GHz -108 -108 -114-114 43.5 GHz to 50 GHz -- -109 ---116Table 17. Direct Receiver Access Input Noise Floor (dBm), Option 201, 217, 219, 401, 417, 419Total average (rms) noise power calculated as the mean value of a linear magnitude trace expressed in dBm. May typically be degraded at particular frequencies below 500 MHz due to spurious receiver residuals.Description Specification TypicalN5224A N5225A N5224A N5225A 10 MHz to 50 MHz -105 -105 -119 -119 50 MHz to 100 MHz -105 -105 -121 -121 100 MHz to 250 MHz -107 -107 -121 -121 250 MHz to 500 MHz -114 -114 -128 -128 500 MHz to 1 GHz -118 -118 -133 -133 1 GHz to 10 GHz -126 -126 -133 -133 10 GHz to 20 GHz -126 -126 -135 -135 20 GHz to 26.5 GHz -124 -124 -134 -134 26.5 GHz to 35 GHz -120 -120 -130 -130 35 GHz to 40 GHz -118 -118 -130 -130 40 GHz to 43.5 GHz -116 -116 -125 -125 43.5 GHz to 50 GHz -- -117 -- -127Table 18a. 0.1 dB Receiver Compression at Test Port (dBm), Option 201, 217, 219, 401, 417, 419 - TypicalDescription N5224A N5225A10 MHz to 100 MHz 15 15100 MHz to 40 GHz 12 1240 GHz to 43.5 GHz 10 1043.5 GHz to 50 GHz -- 10Table 18b. Receiver Compression at Test Power - SpecificationDescription Test Port Power (dBm) Receiver CompressionOption 200, 400Option201, 401Option217, 417Option219, 419Magnitude (dB) Phase (degrees)10 MHz to 500 MHz1 -- -- -- -- -- -- 500 MHz to 10 GHz 11 13 11 11 0.15 1.510 GHz to 16 GHz 10 13 11 11 0.15 1.516 GHz to 20 GHz 10 13 10 10 0.15 1.520 GHz to 26.5 GHz 9 13 10 10 0.18 1.5 26.5 GHz to 30 GHz 9 12 9 9 0.18 1.530 GHz to 32 GHz 9 11 8 8 0.18 1.532 GHz to 35 GHz 9 10 9 9 0.18 1.535 GHz to 43.5 GHz 5 9 8 8 0.18 1.5 43.5 GHz to 47 GHz 1 8 8 8 0.2 1.547 GHz to 50 GHz -5 8 8 8 0.2 1.51Test port receiver compression at specified input levels below 500 MHz due to coupler roll off in this frequency range.Table 19. Trace Noise Magnitude (dB rms)Ratioed measurement, nominal power at test port.Description Specification Typical1 kHz IFBW 1 kHz IFBW 100 kHz IFBW 600 kHz IFBW10 MHz to 50 MHz 0.200 0.071 0.667 1.61250 MHz to 100 MHz 0.020 0.009 0.088 0.209100 MHz to 500 MHz 0.020 0.004 0.040 0.098500 MHz to 1 GHz 0.003 0.001 0.009 0.0221 GHz to 26.5 GHz 0.003 0.001 0.006 0.01526.5 GHz to 43.5 GHz 0.003 0.001 0.009 0.02143.5 GHz to 50 GHz 0.004 0.002 0.007 0.018Table 20. Trace Noise Phase (deg rms)Ratioed measurement, nominal power at test port.Description Specification Typical1 kHz IFBW 1 kHz IFBW 100 kHz IFBW 600 kHz IFBW 10 MHz to 50 MHz 1.000 0.485 4.681 11.310 50 MHz to 100 MHz 1.000 0.062 0.614 1.456 100 MHz to 500 MHz 0.500 0.029 0.276 0.680 500 MHz to 1 GHz 0.020 0.006 0.061 0.1491 GHz to 26.5 GHz 0.020 0.008 0.040 0.100 26.5 GHz to 43.5 GHz 0.030 0.014 0.067 0.159 43.5 GHz to 50 GHz 0.030 0.015 0.061 0.142Table 21. Reference Level Magnitude, All Models and Options - SpecificationDescription Magnitude (dB) Phase (degrees)Range +/- 500 +/- 500 Resolution 0.001 0.01Table 22. Stability, All Options - TypicalDescription Magnitude (dB/°C) Phase (°/°C)10 MHz to 50 MHz 0.020 0.20050 MHz to 3.2 GHz 0.010 0.1003.2 GHz to 10 GHz 0.010 0.20010 GHz to 16 GHz 0.010 0.25016 GHz to 20 GHz 0.015 0.30020 GHz to 26.5 GHz 0.015 0.40026.5 GHz to 35 GHz 0.020 0.60035 GHz to 43.5 GHz 0.020 0.65043.5 GHz to 47 GHz 0.025 0.70047 GHz to 50 GHz 0.027 0.750Table 23. Damage Input Level, All portsDescription Option 200, 201, 219, 400, 401, 419 Option 217, 417RF , DC 27 dBm, 40 V 27 dBm, 7 VDynamic AccuracyDynamic accuracy is verified with the following measurements:Compression over frequencyIF linearity at a single frequency of 1.998765GHz using a reference level of -20 dBm for an input power range of 0 to -60 dBm. For values below -60 dBm, refer to VNA Receiver Dynamic Accuracy Specifications and Uncertainties.Table 24. N5224A and N5225A Dynamic AccuracyN5224A/25A Dynamic Accuracy, 10 MHz to 50 MHz - Specification。