FLUKE718 30G-100G压力校准器用户手册(中文)

合集下载

Fluke 2700G 压力表校准手册说明书

Fluke 2700G 压力表校准手册说明书

September 2013© 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.2700G Reference Pressure Gauge Calibration ManualLIMITED WARRANTY AND LIMITATION OF LIABILITYEach Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption.Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs ofrepair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.Fluke CorporationP.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands11/99Table of ContentsPage TitleIntroduction (1)Contact Fluke Calibration (1)Standard Equipment (2)Safety Information (2)Symbols (3)Maintenance (4)Clean the Product (4)Change the Batteries (4)Specifications (6)Accuracy (6)Media Compatibility (6)Environmental Specifications (6)Mechanical Specifications (6)Available Pressure Ranges (7)Necessary Equipment (7)Calibration Tests (8)Connections (8)Initiate Communication (8)Calibration Steps (9)Serial Point Adjustment (9)Set Zero (9)Set Span (9)Save (10)User-Replaceable Parts (10)i2700GCalibration ManualiiList of TablesTable Title Page (3)1. Symbols2. Necessary Calibration Equipment (7).......................................................................................9Tests3. Calibration10............................................................................Parts4. User-Replaceableiii2700GCalibration ManualivList of FiguresTitle Page Figure1. Change the Batteries (5)8......................................................................................2. TerminalSettingsv2700GCalibration ManualviIntroductionThe 2700G Series Reference Pressure Gauges (the Product) are high-accuracydigital pressure test gauges. Accurate to 0.02 % FS, the Product can be used asa calibration reference or in applications where high-accuracy pressuremeasurement is necessary.The Product features user-configurable functions that include:• Sampling rate• Tare• Damping• Auto off• Min MaxContact Fluke CalibrationTo contact Fluke Calibration, call one of the following telephone numbers:•Technical Support USA: 1-877-355-3225•Calibration/Repair USA: 1-877-355-3225•Canada: 1-800-36-FLUKE (1-800-363-5853)• Europe: +31-40-2675-200• Japan: +81-3-6714-3114• Singapore: +65-6799-5566• China: +86-400-810-3435• Brazil: +55-11-3759-7600•Anywhere in the world: +1-425-446-6110To see product information and download manuals and the latest manualsupplements, visit Fluke Calibration’s website at .To register your product, visit /register-product12700G Calibration Manual2 Standard EquipmentThe Product ships with:•Protective cover (installed)•Three AA alkaline batteries (installed)•2700G Safety Information (printed)•Report of calibration•Manuals CD-ROM with translated users manuals• USB cable• USB power adapter•NPT to ¼ BSP male adapter•NPT to M20 x 1.5 male adapterSafety InformationA Warning identifies conditions and procedures that are dangerous to the user.A Caution identifies conditions and procedures that can cause damage to theProduct or the equipment under test.WarningTo prevent injury, only assemble and operate high-pressuresystems if you know the correct safety procedures. High-pressure liquids and gases are hazardous and the energy fromthem can be released without warning.To prevent possible electrical shock, fire, or personal injury:•Read all safety Information before you use the Product.•Use the Product only as specified, or the protectionsupplied by the Product can be compromised.•Do not use the Product around explosive gas, vapor, or indamp or wet environments.•Do not use and disable the Product if it is damaged.•Remove the batteries if the Product is not used for anextended period of time, or if stored in temperatures above50 °C. If the batteries are not removed, battery leakage candamage the Product.•Replace the batteries when the low battery indicator showsto prevent incorrect measurements.•The battery door must be closed and locked before youoperate the Product.SymbolsCautionTo prevent possible damage to Product or to equipment undertest:•The display reads “OL” when the pressure source is abovethe Product range limit. The pressure source mustimmediately be removed.•Do not apply more than the maximum torque specified.Maximum torque specified is 20 Nm = 15 ft-lb.SymbolsSymbols used on the Product and in this manual are in Table 1.Table 1. SymbolsSymbol Meaning Symbol MeaningRisk of danger. Importantinformation. See manual. Conforms to European Uniondirectives.Hazardous voltage. Risk ofelectrical shock. Conforms to relevant NorthAmerican Safety Standards.Conforms to relevant Australianstandards.This product complies with theWEEE Directive (2002/96/EC)marking requirements. The affixedlabel indicates that you must notdiscard this electrical/electronicproduct in domestic householdwaste. Product Category: Withreference to the equipment types inthe WEEE Directive Annex I, thisproduct is classed as category 9"Monitoring and ControlInstrumentation” product. Do notdispose of this product as unsortedmunicipal waste. Go to Fluke’swebsite for recycling information.Calibration ManualMaintenanceClean the ProductClean the Product with a soft cloth dampened with water or water and weaksoap.CautionTo prevent possible damage to the Product, do not usesolvents or abrasive cleansers.CautionFor safe operation and maintenance of the product:•Repair the Product before use if the battery leaks.•Remove batteries to prevent battery leakage and damage tothe Product if it is not used for an extended period.•Be sure that the battery polarity is correct to prevent batteryleakage.•Have an approved technician repair the Product.Change the BatteriesWarningTo prevent possible electrical shock, fire, or personal injury,have an approved technician repair the Product.To change the batteries, see Figure 1:1. Pull off the Product cover.2. Use a Phillips screwdriver to loosen the captive screw on the battery door.3. Remove the battery door.4. Replace the three AA batteries, note the correct polarity.5. Install the battery door again.6. Tighten the captive screw.7. Put the Product cover back on.Maintenancegsn002.epsFigure 1. Change the BatteriesCalibration ManualSpecificationsInstrumental Measurement UncertaintyPositive Pressure .................................. ±0.02 % FSVacuum ................................................. ±0.05 % FSTemperature Compensation .................. 18 °C to 28 °C (65 °F to 82 °F) to ratedaccuracyNoteFor temperatures from 0 °C to 18 °C and 28 °C to 50 °C, add.003 % FS/°CMedia Compatibility15, 30 psi ............................................... any clean dry non-corrosive gas100, 300, 500, 1000 psi ......................... any liquids or gases compatible with 316stainless steelAbove 1000 psi ...................................... any non-flammable, non-toxic,non-explosive, non-oxidizingliquid or gas compatible with 316stainless steel.Environmental SpecificationsOperating Temperature ......................... 0 °C to 50 °C (32 °F to 122 °F)Storage ................................................. -20 °C to +70 °C (-4 °F to +158 °F)Humidity ............................................... 10 % to 90 % RH Non-condensingAltitude .................................................. 2000 m (6561.68 ft)Pollution Degree (2)Agency Approvals ................................. , ,Mechanical SpecificationsDimensions ........................................... (11.4 x 12.7) cm, depth = 3.7 cm(4.5 x 5) in, depth = 1.5 in(Without protective cover)PressureConnection ................................... ¼ in NPT maleHousing ........................................ Cast ZNALDisplay .......................................... 5-1/2 Digits, 16.53 mm (0.65 in) high20-Segment bar graph, 0 to 100 % PowerBattery ......................................... three size AA alkaline batteriesBattery Life ................................... 75 hours typical without backlightNecessary Equipment Available Pressure RangesModel Number2700G-BG100K2700G -BG200K2700G -BG700K[1]2700G -BG2M[1]2700G -BG3.5M[1]2700G -BG7M[1]2700G -G20M[1]2700G -G35M[1]2700G -G70M[1]Pressure Range (psi) 15 30 100 300 500 10003000 5000 10000PressureRange (MPa)0.1 0.2 0.7 2 3.5 7 20 35 70VacuumRange (psi)-15 -15 -12 -12 -12 -12 0 0 0VacuumRange (kPa)-100 -100 -80 -80 -80 -80 0 0 0 BurstPressure (psi) 45 90 1000 20002000 10000100001000015000BurstPressure(MPa)0.3 0.6 7 14 14 70 70 70 100 ProofPressure (psi) 30 60 200 600 1000 20006000 8000 13000ProofPressure(MPa)0.2 0.4 1.4 4 7 14 40 55 90[1] Measuring or calibrating below -12 psi will invalidate the pressure measurement specification.Necessary EquipmentPressure and/or vacuum standards that can produce and show pressures fromvacuum to the full-scale range of the unit under test (UUT) are necessary forcalibration and adjustment. To maintain the specified Product accuracy, use apressure standard with an uncertainty of ±0.0075 % FS of the Product or lower.The necessary equipment for the calibration procedures is shown in Table 2.Table 2. Necessary Calibration EquipmentModel Name Range RecommendedModelPressureCalibratorMinimum Specification2700G-BG100K -15 psi to 15 psi (-100 kPa to 100 kPa) PG7601 or 2465 ±0.0011 psi (±0.0075 kPa) 2700G-BG200K -15 psi to 30 psi (-100 kPa to 200 kPa) PG7601 or 2465 ±0.0023 psi (±0.015 kPa) 2700G-BG700K -15 psi to 100 psi (-100 kPa to 700 kPa)PG7601 or 2465 ±0.008 psi (±0.0525 kPa)2700G-BG2M -15 psi to 300 psi (-100 kPa to2000 kPa)PG7601 or 2465 ±0.023 psi (±0.15 kPa)2700G-BG3.5M -15 to 500 psi (-100 to 3500 kPa) PG7601 or 2465 ±0.04 psi (±0.2625 kPa)2700G-BG7M -15 psi to 1000 psi (-100 kPa to7000 kPa)PG7601 or 2465 ±0.08 psi (±0.525 kPa)2700G-G20M 0 psi to 3000 psi (0 kPa to 20000 kPa) PG7202 ±0.23 psi (±1.5 kPa) 2700G-G35M 0 psi to 5000 psi (0 kPa to 35000 kPa) PG7202 ±0.4 psi (±2.625 kPa) 2700G-G70M 0 psi to 10000 psi (0 psi to 70000 kPa) PG7202 ±0.8 psi (±5.25 kPa)Calibration ManualCalibration TestsCalibration verifies the complete operation of the Product and measures theaccuracy of each function against Product specifications. If the Product fails apart of the test, adjustment or repair is necessary. See “Serial Point Adjustment”.It is recommended that you apply full-scale pressure to the Product and then ventbefore calibration adjustment. Let the Product stabilize for 1 minute after ventingbefore continued testing.NoteCalibration and adjustment can be performed anywhere in theoperating ambient temperature range of 18 °C to 28 °C (64 °F to82 °F). Calibration or adjustment outside this temperature range willinvalidate the compensation program in the Product. For optimumresults, the calibration or adjustment should be done with ambienttemperature as close as possible to 23 °C (72 °F).ConnectionsThe Product uses a ¼ inch NPT male connection in the pressure input port.Adapters may be necessary to connect to the pressure standard. Make sure thehose, tubing, and fittings have a rated working pressure at or above the pressureof the unit. Make sure there are no leaks when you do the calibration process.Use Teflon tape where necessary.Initiate CommunicationSerial communications can be set up with terminal communication software on aPC, such as Windows HyperTerminal.1. Connect the USB RS232 cable to the serial jack on the rear of the Product.2. Connect the other end of the cable to the PC. Terminal settings are shown inFigure 2.hmo001.bmpFigure 2. Terminal SettingsSerial Point AdjustmentCalibration StepsTo calibrate the Product, apply the values shown in Table 3 for the correctProduct. If the Product fails to show the correct indication, adjustment isnecessary. Calibration can be done in any pressure unit that can be shown onthe Product display. Pressure units of psi and kPa are shown in Table 3 asexamples. If calibrating in other units, use points that are as close as possible tothose in Table 3.Table 3. Calibration TestsModel Calibration Points (psi) Calibration Points (kPa)2700G-BG100K 0, -6, -12, -3, 0, 0, 3, 6, 9, 12, 15 0, -40, -80, -20, 0, 0, 20, 40, 60, 80, 1002700G-BG200K 0, -6, -12, -3, 0, 0, 6, 12, 18, 24, 30 0, -40, -80, -20, 0, 0, 40, 80, 120, 160, 2002700G-BG700K 0, -6, -12, -3, 0, 0, 20, 40, 60, 80, 100 0, -40, -80, -20, 0, 0, 140, 280, 420, 560, 7002700G-BG2M 0, -6, -12, -3, 0, 0, 60, 120, 180, 240, 300 0, -40, -80, -20, 0, 0, 400, 800, 1200, 1600, 20002700G-BG3.5M 0, -6, -12, -3, 0, 0, 100, 200, 300, 400, 500 0, -40, -80, -20, 0, 0, 700, 1400, 2100, 2800, 35002700G-BG7M 0, -6, -12, -3, 0, 0, 200, 400, 600, 800, 1000 0, -40, -80, -20, 0, 0, 1400, 2800, 4200, 5600, 70002700G-G20M 0, 600, 1200, 1800, 2400, 3000 0, 4000, 8000, 12000, 16000, 20000 2700G-G35M 0, 1000, 2000, 3000, 4000, 5000 0, 7000, 14000, 21000, 28000, 35000 2700G-G70M 0, 2000, 4000, 6000, 8000, 10000 0, 14000, 28000, 42000, 56000, 70000 Serial Point AdjustmentAdjustment of the Product is done electronically with internal software. It is notnecessary to open the Product case. All calibration commands and adjustments are done through the serial port connection. If the processes in the next sections do not bring the Product into specification, then it will be necessary to send your Product to Fluke Calibration for calibration adjustment.Set ZeroAfter all connections are made, vent the Product to atmosphere and send thiscommand:OFFSET_ADJ?Note the value that is shown. When the pressure is stable, send:OFFSET_ADJ NN is the pressure given from the previous OFFSET_ADJ? command.Set SpanSend the GAIN_ADJ? command.Note the value shown. Use the correct pressure standard to input a value equal to or near the noted value. When pressure is stable, send:GAIN_ADJ NCalibration ManualN is the entered pressure.Two-point calibration is complete.SavePush the power button to save the calibration adjustment.NoteWhen you calibrate the Product, the results should typically be within50 % of the total uncertainty. For calibration with the serial port, usethe VAL? command. A typical calibration is to be done at 20 %increments first with ascending pressure and then with descendingpressures. The typical procedure for vacuum calibration is to bedone in this order:-6 psi, -12 psi,-3 psi and back to 0 psi.User-Replaceable PartsUser-replaceable parts are shown in Table 4. For more information about theseitems and their prices, contact a Fluke Calibration representative. See the“Contact Fluke Calibration” section.Table 4. User-Replaceable PartsDescription Fluke Part Number Gauge Cover 42010792700G-8004 DECAL BG100K 15PSI 0.1MPA 42011012700G-8005 DECAL BG200K 30PSI 0.2MPA 42011122700G-8006 DECAL BG700K 100PSI 0.7MPA 42011202700G-8007 DECAL BG2M 300PSI 2MPA 42011352700G-8008 DECAL BG3.5M 500PSI 3.5MPA 42011472700G-8009 DECAL BG7M 1000PSI 7MPA 42011582700G-8010 DECAL G20M 3000PSI 20MPA 42011642700G-8011 DECAL G35M 5000PSI 35MPA 42011732700G-8012 DECAL G70M 10000PSI 70MPA 4201186POWER SUPPLY,SW,5W,85-264VAC,5 V@1 A,3 KV,W/MAINS4252495 ADAPTERS,USB OUT,UNIV,WALL MOUNTUSB CABLE,USB TO RS232, 1.8M/5V WIRE END W/ CONN, 44258329 CONTACT, F CBL W/STRAIN RLF2700G Manuals CD 4150074AA Alkaline batteries, NEDA 15A IEC LR6 376756。

福禄克 Fluke 117C 非接触式电压测量万用表 用户手册 说明书

福禄克 Fluke 117C 非接触式电压测量万用表 用户手册 说明书

型号 115C & 117C 115C & 117C 115C & 117C
bAtt CAL Err EEPr Err F11 Err
6
True-rms Multimeters
旋转开关档位
旋转开关档位
开关档位 测量功能 根据所感测到的低阻抗输入情况自动选择交流或直流电压。 交流电压量程:0.06 至 600 V。 频率量程:5 Hz 至 50 kHz。 直流电压量程:0.001 V 至 600 V。 交流电压量程:6.0 mV 至 600 mV,直流耦合。直流电压量程:0.1 至 600 mV。 电阻量程:0.1 至 40 M。 电阻小于 20 时,蜂鸣器打开;电阻大于 250 时,蜂鸣器关闭。 二极管测试。电压超过 2.0 V 时,显示过载(OL)符号。 电容量程(法拉):1 nF 至 9999 F。 交流电流量程:0.1 A 至 10 A(> 10 至 20 A,30 秒开,10 分钟关)。 > 10.00 A 显示屏闪烁。> 20 A,显示 OL(过载)。直流耦合。 频率量程:45 Hz 至 5 kHz。 直流电流量程:0.001 A 至 10 A(> 10 至 20 A,30 秒开,10 分钟关)。 > 10.00 A 显示屏闪烁。> 20 A,显示 OL(过载)。 非接触式感测交流电压。 型号 117C 115C & 117C 115C & 117C 115C & 117C 115C & 117C 115C & 117C 115C & 117C 115C & 117C 115C & 117C 115C & 117C 115C & 117C 117C

FLUKE PPC4压力控制器 校准器 说明书

FLUKE PPC4压力控制器 校准器 说明书

FLUKE 新一代 PPC4 压力控制器/校准器,更高性能,更多功能,更高可靠性 全新彩色图形界面,一键式导航功能 美国亚利桑那州凤凰城消息——美国福禄克(FLUKE)公司旗下的压力校准品牌 DHI近日发布了一款全新高性能压力控制器/校准器 PPC4,它具有多功能和易于使用的特点,可广泛应用于校准实验室和压力产品生产线。

PPC4 可以控制绝压、表压及非常低的差压,量程从 1KPa 到 10MPa。

拥有高性能的同时,PPC4 的单一控制器可以覆盖更广的量程范围,并保证更低的测量不确定度。

 PPC4 使用了独一无二且具有独特特性化的石英参考压力传感器,从而提高了准确度、减小了测量的不确定度。

AutoRange™ 功能支持无限量程,可以针对被校准设备的量程进行优化操作。

PPC4 的结构坚固,便于移动应用,运输时也无需进行特殊包装。

 用户可以依据自身的具体应用和预算情况选择两种不同的用户界面。

当使用计算机进行控制时,可选择基本界面。

否则可以选择高级界面,这一全新用户界面具有彩色图形显示和独特的一键式导航旋钮功能,简化了 PPC4 的压力校准和测试工作。

两种界面方式均包含一个 USB 接口以及用于 PC 机即插即用功能的免费操控软件。

 PPC4 拥有所有专业、先进的性能指标,包括压力“准备好/未准备好”显示功能、实时地计算和显示压力的不确定度、精准的动态控制精度以及控制量程比。

它的开放式架构模式,支持无限的系统配置,以满足特定的应用需求,还可通过闪存对 PPC4 内部软件进行简便、无限制的升级。

 。

Fluke 707_用户手册中文版(回路校准器)

Fluke 707_用户手册中文版(回路校准器)
同时按 B + C 进入“自动斜波输出”模式并步进到一个斜波输
出类型。 校准器在 0-20 毫安或 4-20 毫安量程间距内以三种斜波输出类型之一 施加或控制一个不断重复的毫安信号: 慢 (e) 40 秒内 0 % 到 100 % 到 0 % 平缓斜波输出。 快 (g) 15 秒内 0 % 到 100 %到 0 % 平缓斜波输出。 步进 (f) 以 25 % 为步长,从 0 % 到 100 % 再到 0 % 的阶梯斜波
清洁 定期用湿布和清洁剂清洁仪表外壳,切勿使用腐蚀剂或溶剂。
校准 每年校准一次校准器可确保它的性能符合指标要求。
更换电池
W 警告
为避免错误的读数而可能导致触电或人身伤害,显示屏上出现 M (电池电能过低) 符号时,应立即更换电池。
只用一节正确安装的 9 伏电池给校准器供电。
校准器使用一节 9 伏碱性电池(ANSI/NEDA 1604A 或 IEC 6LR61)。 若要更换电池:
1. 按 D 关闭 (OFF) 校准器。
2. 从端子断开测试线。
3. 取下皮套。
4. 如图所示打开校准器后部的电池盖。
5. 取出电池。
6. 放入更换的电池,关上电池盖。确保电池固定在位。
7. 把校准器放回皮套内。
ADA07F.EPS
HART 模式
要启用或禁用校准器的 HART 模式(HART,可寻址远程传感器数据 公路),请参见“按钮功能”部分的“开启选项”。缺省状态下, HART 电阻器关闭。
707 LOOP CALIBRATOR
CAT 30V
COM
+
AMP03F.EPS
用回路电源测量直流毫安
W小心 为避免测试时损坏被测装置,确保在连接测试线之前,先将校准 器置于正确的模式。 在回路电源档下,校准器能为变送器提供 +24 伏的回路电源,并同时 读出回路电流。 用回路电源测量直流毫安

fluke中文使用手册421

fluke中文使用手册421
.................................................................................................... FCC 声明(仅美国) ..................................................................................................... 激光等级 ................................................................................................................... 一体化测距仪........................................................................................................ 二级激光产品: .................................................................................................... 启动 ............................................................................................................................... 安装/更换电池 ........................................................................................................... 改变基准点(多功能尾端件) ................................................................................... 小键盘 ....................................................................................................................... 显示屏 ....................................................................................................................... 菜单功能 ........................................................................................................................ 设置........................................................................................................................... 菜单导航 ............................................................................................................... 概述 ...................................................................................................................... 设置距离测量的单位.................................................................................................. 倾斜测量的单位设置.................................................................................................. 蜂鸣 (BEEP).............................................................................................................. Continuous laser () .............................................................................................. 用三脚架测量(TRIPOD) ............................................................................................ 显示屏 - 键盘的照明() ............................................................................................ 复位 - 恢复出厂设置 (RESET)................................................................................... 操作 ............................................................................................................................... 开启和关闭 ................................................................................................................ 清除键 ....................................................................................................................... 显示屏 - 键盘的照明 .................................................................................................. 设置测量基准边 ......................................................................................................... 测量 ............................................................................................................................... 单个距离测量 ............................................................................................................ 最小/最大距离测量 .................................................................................................... 4 4 5 5 5 6 6 7 8 9 10 10 10 10 12 12 12 12 12 13 13 13 13 13 13 13 14 14 14

FLUKE187、189真有效值多用表校准手册(中文版)

FLUKE187、189真有效值多用表校准手册(中文版)

自购买日起十年内,本保证也包括LCD。十年以后直到仪表的终生,Fluke将以收费的方式更换 DMM的LCD(根据当时该组件的成本价格收取费用)。
欲建立原购买者与购买日期的根据,请填妥并寄回产品所附上的注册登记卡,或在 上注册产品。对于从Fluke授权销售处以适当的国际价格所购买而损坏的 产品,Fluke可选择免费修理、更换或以原购买价退款的方式处理该产品。若产品是从一个国家 购买却被送到其它地区修理,Fluke保留收取修理/更换零件的进口费用的权利。
dBm功能用户可以选择参考电阻。 显示具有读数保持功能 蜂鸣器在电阻低于阈值或电路瞬间开路时会发出响声。 从峰值到零之间共分 51 段 以%数或毫秒单位来测量信号的开启或关闭时间 记录最大、最小和平均值. 24小时钟用来记录MAX或MIN测量值的发生时间,平均值的经历时间 FAST MN MX 模式能够捕获 250 微秒的峰值
特性概要…………………………………………………………………5
基本技术指标…………………………………………………………………6
详细精度技术指标……………………………………………………………7
频率计数器灵敏度……………………………………………………………10
负载电压(A,mA,μA)…………………………………………………10
FAST MN MX(24小时时标) 闭壳校准 Battery / Fuse盖 高强度注模外壳
描述
主显示:
50,000 字
次显示:
5,000 字
条状图:
51 端, 更新速率 40 次/秒
白色背光在照明条件不好的环境中可以提供清晰的读数。
在测量过程中数表会立即选择正确的量程
选择交流、交流和直流双显示或交流+直流测量读数

Fluke 714 热电偶校准器说明书

Fluke 714 热电偶校准器说明书

®714Thermocouple CalibratorInstruction SheetIntroductionThe Fluke 714 Thermocouple Calibrator is a precise source and measurement tool for calibrating thermocouple instruments. The calibrator sources or measures in units of °C, °F, or mV, through a thermocouple minijack.Your calibrator is supplied with a Flex-Stand ™ holster, aninstalled 9 V alkaline battery, and this instruction sheet. Sets of thermocouple miniplugs are available from Fluke. (Accessories Fluke-700TC1 and Fluke-700TC2 TC Miniplug Kits.)If the calibrator is damaged or something is missing, contact the place of purchase immediately. Contact your Fluke distributor for information about accessories. To order replacement parts or spares, see “Replacement Parts.”The following tables list the thermocouple types supported by the calibrator, the standards and scales used for each type, thethermocouple properties, and calibrator resolution. Full calibrator specifications are listed at the end of this instruction sheet.NoteSince mV input and output units are available, you can use the calibrator for any thermocouple type by making manual calculations or referring to tables.PN 650306 July 1997 Rev. 1, 10/97©1997 Fluke Corporation. All rights reserved. Printed in U.S.A.All product names are trademarks of their respective companies.1.888.475.5235*********************Fluke -Direct.comThermocouple Standards and Scales Thermocouple Type Standard Scale J, K, T, E, R, S, B NIST 175ITS-90 L (J-DIN), U (T-DIN)DIN 43710IPTS-68Thermocouple PropertiesThermocoupleType TemperatureRangesDisplay ResolutionJ-200 to 1200°C,-328 to 2192°F0.1°C or °FK-200 to 1370°C-328 to 2498°F0.1°C or °FT-200 to 400°C-328 to 752°F0.1°C or °FE-200 to 950°C-328 to 1742°F0.1°C or °FR-20 to 1750°C-4 to 3182°F1°C or °FS-20 to 1750°C-4 to 3182°F1°C or °FB600 to 1800°C1112 to 3272°F1°C or °FL-200 to 900°C-328 to 1652°F0.1°C or °FU-200 to 600°C-328 to 1112°F0.1°C or °F1.888.475.5235 *********************Millivolt Range and ResolutionMode Range Display ResolutionmV-10 to 75 mV0.01 mVExplanation of International SymbolsThe following symbols are used on the calibrator or in thisinstruction sheet. The table below explains their meaning.International SymbolsSymbol MeaningJ Earth groundI FuseM BatteryW Refer to this instruction sheet for information aboutthis feature.T Double insulatedConforms to relevant Canadian StandardsAssociation directives.P Conforms to European Union directives*********************1.888.475.5235Safety InformationW WarningTo avoid possible electric shock or personal injury:•Never apply more than 30 V between the TCterminals, or between either TC terminal andearth ground.•Make sure the battery door is closed andlatched before you operate the calibrator.•Remove an attached thermocouple miniplugfrom the calibrator before you open the batterydoor.•Do not operate the calibrator if it is damaged.•Do not operate the calibrator around explosivegas, vapor, or dust.When servicing the calibrator, use only specified replacementparts.Turning the Calibrator OnPress the green O pushbutton to turn the calibrator on and off.*********************1.888.475.5235Measuring a Thermocouple*********************1.888.475.5235Simulating a Thermocouple*********************1.888.475.5235MaintenanceFor maintenance procedures not described in this sheet, contacta Fluke Service Center.In Case of Difficulty•Check the battery and thermocouple test wiring. Replace as necessary.•Review this sheet to make sure you are using the calibrator correctly.If the calibrator needs repair, contact a Fluke Service Center. Ifthe calibrator is under warranty, see the warranty statement forterms. If the warranty has lapsed, the calibrator will be repairedand returned for a fixed fee. Contact a Fluke Service Center forinformation and price.CleaningPeriodically wipe the case with a damp cloth and detergent; donot use abrasives or solvents.CalibrationCalibrate your calibrator once a year to ensure that it performsaccording to its specifications. A calibration manual is available(PN 686540). Call 1-800-526-4731 from the USA and Canada. Inother countries, contact a Fluke Service Center.Replacing the BatteryWhen the M symbol appears on the display, replace thebattery with a 9 V alkaline battery.*********************1.888.475.5235it07f.eps Replacing the Fuse! WarningTo avoid personal injury or damage to thecalibrator, use only a 0.125A 250V fast fuse,Littelfuse® 2AG.Fuse F1 is probably blown if in the input mode, the calibratoralways reads OL, even with a thermocouple connected.*********************1.888.475.5235Replace the fuse as follows:1. Remove the test leads and turn the calibrator off.2. Remove the battery door.3. Remove the three Phillips-head screws from the casebottom and turn the case over.4. Gently lift the top cover from the end nearest the input/outputterminals until it unsnaps from the bottom cover.5. Replace the fuse with a 0.125 A 250 V fast fuse, Littelfuse®2AG.6. Fit the top and bottom covers together, engaging the twosnaps. Make sure that the gasket is properly seated.Reinstall the three screws.7. Replace the battery door.*********************1.888.475.5235ke03f.eps1.888.475.5235*********************Replacement Parts and AccessoriesReplacement PartsItem Description PN orQty.Modelno.BT19V battery, ANSI/NEDA 1604A or6144871IEC 6LR61CG81Y Holster, Yellow CG81Y1! F1Fuse, 125 mA, 250V fast6865271MP85Case top6202341MP86Case bottom6201681H2, 3, 4Case screw8322463MP89, 90Non-skid foot8244662MP92Battery door6199471H5, 6Battery door fasteners9486092S1Keypad6870761−714 Instruction Sheet5603061−71X Series Calibration Manual686540Option*********************1.888.475.5235H5, 6HolsterInstruction Sheetke04c.eps1.888.475.5235*********************Fluke -Direct .comSpecificationsSpecifications are based on a one year calibration cycle andapply for ambient temperature from +18°C to +28°C unlessstated otherwise. “Counts” means number of increments ordecrements of the least significant digit.Temperature Measure and Thermocouple SimulateTC Type Resolution Error ReferenceJunctionError J, K, T, E, L, U0.1°C or °F±(0.3°C + 10 µV)±0.2°CB, R, S1°C or °F±(0.3°C + 10 µV)±0.2°CMaximum input voltage: 30 VMillivolt Measure and SourceRange Resolution Accuracy-10 mV to 75 mV0.01 mV±(0.025% + 1 count)Maximum input voltage: 30 V*********************1.888.475.5235General SpecificationsMaximum voltage applied between any terminal and earthground or between any two terminals: 30 VStorage temperature: -40°C to 60°COperating temperature: -10°C to 55°COperating altitude: 3000 meters maximumTemperature coefficient: 0.05 x specified accuracy per °C fortemperature ranges -10°C to 18°C and 28°C to 55°CRelative humidity: 95% up to 30°C, 75% up to 40°C, 45% up to50°C, and 35% up to 55°CVibration: Random 2 g, 5 Hz to 500 HzShock: 1 meter drop testSafety: Certified as compliant to CAN/CSA C22.2 No.1010.1:1992. Complies with ANSI/ISA S82.01-1994.Power requirements: Single 9 V battery (ANSI/NEDA 1604A orIEC 6LR61)Size: 32 mm H x 87 mm W x 187 mm L (1.25 in H x 3.41 in W x7.35 in L);With holster and Flex-Stand: 52 mm H x 98 mm W x 201 mm L(2.06 in H x 3.86 in W x 7.93 in L)Weight: 332 g (11.7 oz);With holster and Flex-Stand: 584 g (20.6 oz)*********************1.888.475.5235How to Contact FlukeTo order accessories, receive operating assistance, or get thelocation of the nearest Fluke distributor or Service Center, call:1-800-44FLUKE (1-800-443-5853) in U.S.A. and Canada+31-402-678-200 in Europe+1-425-356-5500 from other countriesAddress correspondence to:Fluke Corporation Fluke Europe B.V.P.O. Box 9090,P.O. Box 1186,Everett, WA 98206-9090 5602 BD EindhovenU.S.A.The NetherlandsVisit us on the World Wide Web at: LIMITED WARRANTY & LIMITATION OF LIABILITYThis Fluke product will be free from defects in material and workmanshipfor three years from the date of purchase. This warranty does not coverfuses, disposable batteries or damage from accident, neglect, misuse orabnormal conditions of operation or handling. Resellers are notauthorized to extend any other warranty on Fluke’s behalf. To obtainservice during the warranty period, send your defective calibrator to thenearest Fluke Authorized Service Center with a description of theproblem.THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHERWARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE,ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANYSPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGESOR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since somestates or countries do not allow the exclusion or limitation of an impliedwarranty or of incidental or consequential damages, this limitation ofliability may not apply to you.*********************1.888.475.5235。

700G 系列压力表使用说明书

700G 系列压力表使用说明书

700G SeriesPressure Gauges用户手册November 2011, Rev. 2, 8/17 (Simplified Chinese)© 2011-2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.All product names are trademarks of their respective companies.在正常使用和维护条件下,Fluke公司保证每一个产品都没有材料缺陷和制造工艺问题。

保证期为从产品发货之日起二(2)年。

部件、产品修理和服务的保证期限为90天。

本项保证仅向授权零售商的原始买方或最终用户提供,并且不适用于保险丝和一次性电池或者任何被Fluke公司认定由于误用、改变、疏忽、意外非正常操作和使用所造成的产品损坏。

Fluke公司保证软件能够在完全符合性能指标的条件下至少操作90天,而且软件是正确地记录在无缺陷的媒体上。

Fluke公司并不保证软件没有错误或无操作中断。

Fluke公司仅授权零售商为最终客户提供新产品或未使用过产品的保证。

但并未授权他们代表Fluke公司提供范围更广或内容不同的保证。

只有通过Fluke授权的销售商购买的产品,或者买方已经按适当的国际价格付款的产品,才能享受Fluke的保证支持。

在一个国家购买的产品被送往另一个国家维修时,Fluke公司保留向买方收取修理/更换零部件的进口费用的权利。

Fluke公司的保证责任是有限的,Fluke公司可以选择是否将依购买价退款、免费维修或更换在保证期内退回到Fluke公司委托服务中心的有缺陷产品。

要求保修服务时,请与就近的Fluke授权服务中心联系,获得退还授权信息;然后将产品连同问题描述寄至该服务中心,并预付邮资和保险费用(目的地离岸价格)。