检验方法确认美国药典usp1225

检验方法确认美国药典usp1225
检验方法确认美国药典usp1225

验证: Validation 针对新方法(没有法定方法, 需要用户自己建立的) 按照ICH Q2 或USP<1225>的方式

均可; 主要是需要满足使用目的.

<1225>VALIDATION OF COMPENDIAL PROCEDURES

药典规程的验证

Test procedures for assessment of the quality levels of pharmaceutical articles are subject to various requirements. According to Section 501 of the Federal Food, Drug, and Cosmetic Act, assays and specifications in monographs of the United States Pharmacopeia and the National Formulary constitute legal standards. The Current Good Manufacturing Practice regulations [21 CFR 211.194(a)] require that test methods, which are used for assessing compliance of pharmaceutical articles with established specifications, must meet proper standards of accuracy and reliability. Also, according to these regulations [21 CFR 211.194(a)(2)], users of analytical methods described in USP-NF are not required to validate the accuracy and reliability of these methods, but merely verify their suitability under actual conditions of use. Recognizing the legal status of USP and NF standards, it is essen tial, therefore, that proposal for adoption of new or revised compendial analytical procedures be supported by sufficient

laboratory data to document their validity.

评估药品质量水平的实验方法受到多种要求的影响。要依据美国食品、药品、化妆品法案501款以及美国药典和国家处方集的各论中的含量测定和质量标准来构建法定标准。现行药品生产质量管理规范【21 CFR 211.194(a)】要求,用于评价药物与既有质量标准之间的符合性的分析规程必须在准确度和可靠性方面达到适当的标准。并且根据【21 CFR 211.194(a)(2)】的这些规定,不要求USP-NF(《美国药典/国家处方集》)中描述的分析方法/规程的使用者去验证这些规程的准确度和可靠性,而仅需确认其在正确实际使用条件下的适用性。认识到USP和NF标准的法定地位,因此,提议采纳新的或更改过的药典分析规程时,必须有充分的实验室数据作为支持,以记录其有效性。

The text of this information chapter harmonizes, to the extent possible, with the Tripartite International Conference on Harmonization (ICH) documents Validation of Analytical Procedures and the Methodology extension text, which are concerned with analytical procedures included as part of registration applications submitted within the EC, Japan, and the USA.

本信息章节的内容尽可能地与三方国际协调会议(ICH)文件分析规程的验证和方法学的延伸内容保持一致,那是与包含欧盟、日本和美国注册申请内的分析方法相关的。

SUBMISSIONS TO THE COMPENDIA

向药典提交的文件

Submissions to the compendia for new or revised analytical procedures should contain sufficient information to enable members of the USP Council of Experts and its Expert Committees to evaluate the relative merit of proposed procedures. In most cases, evaluations involve assessment of the clarity and completeness of the description of the analytical procedures, determination of the need for the procedures, and documentation that they have been appropriately validated. Information may vary

depending upon the type of method involved. However, in most cases a submission will consist of the

following sections.

向药典提交关于新的或更改过的分析规程的文件应该包括充足的信息,以使USP专家理事会和专家委员会能够评估拟议规程的相对优越性。在大多数情况下,这些评估涉及对分析规程描述的清晰度和完整度的评估,对规程的需求的确定,以及它们已经进行了适当验证的记录文件。这些信息可以根据所涉及规程的种类而变化。但是,在大多数情况下,提交的文件将有下面的章节组成。

Rationale---- This section should identify the need for the procedure and describe the capability of the specific procedure proposed and why it is preferred over other types of determinations. For revised procedures, a comparison should be provided of limitations of the current compendial procedure and

advantages offered by the proposed procedure.

理论依据---- 此部分应该辨明对于该规程的需求,并描述具体拟议中规程的能力,以及为什么优于其他种类检测。对于更改的方法/规程,应该提供对当前药典规程之缺陷与拟议中规程之优势的比较。

Proposed Analytical Procedure--- This section should contain a complete description of the analytical procedure sufficiently detailed to enable persons “skilled in the art” to replicate it. The write-up should include all important operational parameters and specific instructions such as preparation of reagents, performance of system suitability tests, description of blanks used, precautions, and explicit

formulas for calculation of test results.

推荐的分析方法/规程---- 此部分包含对该分析规程的完整描述,应足够具体以便能让业内技术熟练的人重复它。文章应该包括所有重要的操作参数和具体的指令,例如:试剂制备、系统适用性测试表现、所使用空白对照的描述、预防措施、用于计算测试结果的明确公式。

Data Element---- This section should provide thorough and complete documentation of the validation of the analytical procedure. It should include summaries of experimental data and calculations substantiating each of the applicable analytical performance characteristics. These characteristics are

described in the following section.

数据要素---- 此部分应该提供完全彻底的分析规程验证记录文件。其应该包括对于证明每一个实用功能特性的实验数据和计算的概况、总结。这些特性在下面的部分描述。

VALIDATION

验证

Validation of an analytical procedure is the process by which it is established, by laboratory studies, that the performance characteristics of the procedure meet the requirements for the intended analytical applications. Typical analytical performance characteristics that should be considered in the validation of the types of procedures described in this document are listed in Table 1. Because opinions may differ with respect to terminology and use, each of the performance characteristics is defined in the next

section of this chapter, along with a delineation of a typical method or methods by which it may be

measured.

分析规程的验证是,通过实验室研究,确定该规程的工作特性达到了预定分析用途要求的过程。在此文件中所描述的规程种类的验证中,应当考虑的常见分析工作特性在表1中列出。因为对于术语和使用的意见可能不同,在此通则的下个部分定义了每个工作性能,以及可以对其进行测量的常用的一个或几个

方法的描绘。

Table 1. Typical Analytical Characteristics Used in Method Validation

表1. 在方法验证中使用的常用分析特性

In the case of compendial procedures, revalidation may be necessary in the following cases: a submission to the USP of a revised analytical procedure; or the use of an established general procedure with a new product or raw material (see below in Data Elements Required for Validation).

在药典方法的情况下,在下面的情况有必要进行再验证:向USP提交修改的分析规程;或将已确立的通用规程用于新产品或原料(见下面验证必需的数据要素)

The ICH documents give guidance on the necessity for revalidation in the following circumstances: changes in the synthesis of the drug substance; changes in the composition of the drug product; and

changes in the analytical procedure.

ICH文件对于下列情况下再验证的必要性做出了指导:药物合成过程有变更;药品组成的有变更;以

及分析规程中有变更。

Analytical Performance Characteristics

分析性能特征

ACCURACY

准确度

Definition---- The accuracy of an analytical procedure is the closeness of test results obtained by that procedure to the true value. The accuracy of an analytical procedure should be established across

its range.

定义---- 分析规程的准确度是由该规程得到的测试结果与真实值的接近程度。分析规程的准确度应通

过它的适用范围来建立。

Determination---- In the case of the assay of a drug substance, accuracy may be determined by application of the analytical procedure to an analyte to known purity (e.g., a Reference Standard) or by comparison of the results of the procedure with those of a second, well-characterized procedure, the

accuracy of which has been stated or defined.

测定---- 当对一种药物进行分析时,准确度可以通过该分析规程来分析一个已知纯度的物质(例如,某个标准物质)来进行测定,或者通过比较运用这个分析方法所得的结果与另一个已经鉴定的、其准确度

已被说明或被解释过的方法所得的结果来进行测定。

In the case of the assay of a drug in a formulated product, accuracy may be determined by application of the analytical procedure to synthetic mixtures of the drug product components to which known amounts of analyte have been added within the range of the procedure. If it is not possible to obtain samples of all drug product components, it may be acceptable either to add known quantities of the analyte to the drug product (i.e., “to spike”) or to compare results with those of a s econd, well-characterized procedure, the accuracy of which has been stated or defined.

当分析一种成品药时,准确度可以通过分析规程来分析成药各组分的合成物质来测定,而添加进去的分析物质是在方法的范围之内的、是已知数量的。如果不能得到成药的所有组分,也可以将已知数量的待分析物加入到该成药中(例如,“增敏”),或者将结果与用第二种、成熟的、已知准确度的规程得到的

结果进行比较,

In the case of quantitative analysis of impurities, accuracy should be assessed on samples (of drug substance or drug product) spiked with known amount of impurities. Where it is not possible to obtain samples of certain impurities or degradation products, results should be compared with those obtained by an independent procedure. In the absence of other information, it may necessary to calculate the amount of an impurity based on comparison of its response to that of the drug substance; the ratio of the response of equal amounts of the impurity and the drug substance (relative response factor) should be

used if known.

对于杂质的定量分析,应使用以已知数量杂质增敏的样品来评估准确度。当不能获得特定杂质或降解产物的样品时,应将结果与另一独立方法获得的结果进行比较。在没有其他信息的情况下,可能必需通

过将某种杂质的响应值与药物的响应值进行比较来计算杂质的数量;同等数量的杂质与药物的响应值的比

值(相对响应因子),如果已知,则应使用。

Accuracy is calculated as the percentage of recovery by the assay of the known added amount of analyte in the sample, or as the difference between the mean and the accepted true value, together with

confidence interval.

通过测定被加入到样品中的已知数量的被分析物来计算准确度,得到回收百分比,或得到平均值与

可接受的真实值之间的差异,同置信区间一起。

The ICH documents recommended that accuracy should be assessed using a minimum of nine determinations over a minimum of three concentration levels, covering the specified range (i.e., three concentrations and three replicates of each concentration).

ICH文件建议精密度的评估应当使用覆盖规定范围的至少三个浓度水平进行至少九次测试(例如,三

个浓度并且每个浓度三次重复进样)。

Assessment of accuracy can be accomplished in a variety of ways, including evaluating the recovery of the analyte (percent recovery) across the range of the assay, or evaluating the linearity of the relationship between estimated and actual concentrations. The statistically preferred criterion is that the confidence interval for the slope be contained in an interval around 1.0, or alternatively, that the slope be close to 1.0. In either case, the interval or the definition of closeness should be specified in the validation protocol. The acceptance criterion will depend on the assay and its variability and on the product. Setting an acceptance criterion based on the lack of statistical significance of the test of the null hypothesis that

the slop is 1.0 is not an acceptable approach.

准确度的评估可以通过多种不同的方式完成,包括评价在含量测定的整个范围内被分析物的回收率,或评价估计浓度与实际浓度之间关系的线性。具统计学意义的标准有二,一是斜率的置信区间被限定在约1.0的区间,二是此斜率接近1.0。在任意一种情况下,此区间或接近程度的定义应该在验证方案中明确规定。接受标准将取决于含量和其差异性,以及取决于该产品。通过测试证明该斜率为1.0的零假设没

有统计学意义,这样的方法不能用于设定接受标准。

PRECISION

精密度

Definition---- The precision of an analytical procedure is the degree of agreement among individual test results when the procedure is applied separately to multiple samplings of a homogeneous sample.

The precision of an analytical procedure is usually expressed as the standard deviati on or relative standard deviation (coefficient of variation) of a series of measurements. Precision may be a measure of either the degree of reproducibility or of repeatability of the analytical procedure under normal operating conditions. In this context, reproducibility refers to the use of the analytical procedure in different

laboratories, as in a collaborative study. Intermediate precision (as known as ruggedness) express within-laboratory variation, as on different days, or with different analysts or equipment within the same laboratory. Repeatability refers to the use of the analytical procedure within a laboratory over a short period of time using the same analyst with the same equipment.

定义---- 分析规程的精密度是当该分析规程单独分析均质样品的多个样本时,若干检验结果的一致程度。分析规程的精密度通常以一系列测量数值的标准差或相对标准差(变异系数)来表示。精密度可以是分析规程在普通操作条件下可重现性或可重复性程度的度量单位。在这样的背景下,重现性指的是该分析规程在不同实验室的应用,例如在一个协作实验室里进行研究。中间精密度(也称为“耐用性”)体现了在实验室内的差异,如在相同的实验室,但在不同的日期,或使用不同的分析员或设备。可重复性指的是在同一个实验室内,一段较短的时间内,相同的分析员使用相同的设备、同一个分析方法的应用情况。

Determination---- The precision of an analytical procedure is determined by assaying a sufficient number of aliquots of a homogeneous sample to be able to calculate statistically valid estimates of standard deviation or relative standard deviation (coefficient of variation). Assays in this context are independent analyses of samples that have been carried through the complete analytical procedure from

sample preparation to final test result.

测定----一个分析方法的精密度是通过对足够的同一样品的分析来计算有统计学意义的标准偏差或相对标准偏差来测定的。在这个背景下的分析是从样品准备到最终实验结果的完整分析程序的对样品的独立

分析。

The ICH documents recommended that repeatability should be assessed using a minimum of nine determinations covering the specified range for the procedure (i.e., three concentration and three replicates of each concentration or using a minimum of six determinations at 100% of the test

concentration).

ICH文件建议可重复性的评估应该使用最少九次检测,覆盖该分析规程所规定的范围(例如,三个浓度和每个浓度三次重复进样,或在100%测试浓度上进行最少六次测定)。

SPECIFITY

专属性

Definition---- The ICH documents define specificity as the ability to assess unequivocally the analyt in the presence of components that may be expected to be present, such as impurities, degradation products, and matrix components. Lack of specificity of an individual analytical procedure may be compensated by other supporting analytical procedures. [NOTE--- Other reputable international authorities (IUPAC, AOAC-I) have preferred the term “selectivity”, reserving “specificity” for those procedures that are completely selective.] For the tests discussed below, the above definition has the

following implications.

定义---- ICH文件将专属性定义是当待分析物含有预期会有的其他组分(例如,杂质、降解产物、矩阵组分)时,准确可靠地评估待分析物的能力。某个分析规程缺乏专属性可以通过其他辅助性分析规程进行补偿。【注意:其他声誉卓著的国际权威机构(IUPAC、AOAC-I)已经提出术语“选择性”,而将“专属性”

留给已经具有完全选择性的规程。】对于下面讨论的测试,上述定义具有以下的含义。

Identification Tests: ensure the identity of the analyte.

鉴别检测:确保待分析物的鉴别。

Purity Tests: ensure that all the analytical procedures performed allow an accurate statement of the content of impurities of an analyte (e.g., related substances test, heavy metals limit, organi c volatile

impurities).

纯度检测:确保执行的所有分析规程能够令对于待分析物各杂质含量的准确陈述得以做出。

Assays: provide an exact result, which allow an accurate statement on the content or potency of

the analyte in a sample.

含量检测:提供准确的结果,令对样品中待分析物的含量或效力的准确陈述得以做出。

Determination---- In the case of qualitative analyses (identification tests), the ability to select between compounds of closely related structure that are likely to be present should be demonstrated. This should be confirmed by obtaining positive results (perhaps by comparison to a known reference material) from samples containing the analyte, coupled with negative results from samples that do not contain the analyte and by confirming that a positive response is not obtained from materials structurally

similar to or closely related to the analyte.

测定---- 对于定性分析(鉴别检验),应当论证其在可能存在的、结构密切相关的物质中进行选择的能力。从含有待分析物的样品中得到阳性结果(可能通过与已知标准物质的比较),而从不含待分析物的样品得到阴性结果,以对其选择能力加以确认,并还要确认阳性响应不是来自与待分析物结构相似或密切

相关的物质。

In the case of analytical procedures for impurities, specificity may be established by sp iking the drug substance or product with appropriate levels of impurities and demonstrating that these impurities are determined with appropriate accuracy and precision.

对于检测杂质的分析规程,专属性可以通过以适当水平的杂质将原料药或成药增敏,并论证这些杂

质的测定达到了适当的准确度和精密度。

In the case of the assay, demonstration of specificity requires that it can be shown that the procedure is unaffected by the presence of impurities or excipients. In practice, this can be done by

spiking the drug substance or product with appropriate levels of impurities or excipients and demonstrating that the assay result is unaffected by the presence of these extraneous materials.

对于含量检测,对专属性的论证要求能够显示出该分析规程不受各杂质或辅料的影响。在实际操作中,通过以适当水平的杂质或辅料将原料药或成药增敏,并证明含量检验结果不受这些外来物质的影响,

来完成论证。

If impurity or degradation product standards are unavailable, specificity may be demonstrated by comparing the test results of samples containing impurities or degradation products to a second well-characterized procedure (e.g., Pharmacopeial or other validated procedure). These comparisons should include samples stored under relevant stress conditions (e.g., light, heat, humidity, acid/base hydrolysis, oxidation). In the case of assay, the results should be compared; in the case of chromatographic impurity test, the impurity profiles should be compared.

如果没有杂质或降解产物的标准品,可以通过将含有杂质或降解产物的样品的测试结果与第二种、成熟规程(例如,药典或其他验证过的规程)的结果进行比较,来论证专属性。这些比较应该包括在相关破坏性条件下(例如,光、热、湿度、酸/碱水解、氧化作用)存储的样品。对于含量测定,应比较其结果;

对于色谱法杂质检测,应比较杂质概况。

The ICH documents state that when chromatographic procedures are used, representative chromatograms should be presented to demonstrate the degree of selectivity, and peaks should be appropriately labeled. Peak purity tests (e.g., using diode array or mass spectrometry) may be useful to show that the analyte chromatographic peak is not attributable to m ore than one component.

ICH文件声明,当使用色谱分析规程时,应提交具代表性的色谱图,以论证选择性的程度,而且应对色谱峰作适当的标识。也可以使用色谱峰纯度测试(例如,使用二极管阵列或质谱仪),来显示待分析物

的色谱峰仅产生于一个组分。

DETECTION LIMIT检测限度

Definition---- The detection limit is a characteristic of limit tests. It is the lowest amount of analyte in a sample that can be detected, but not necessarily quantitated, under the stated experimental conditions. Thus, limit tests merely substantiate that the amount of analyte is above or below a certain level. The detection limit is usually expressed as the concentration of analyte (e.g., percentage, parts per billion) in

the sample.

定义---- 检测限度是限度检测的特性。它是指在规定的试验条件下,样品中可被检测到的待分析物的最小数量,但是无需定量。因此,限度检测仅仅说明了待分析物的数量高于或低于某个特定水平。检测限度通常以在样品中的待分析物浓度(例如,百分比、十亿分率)表示。

Determination---- For non-instrumental procedures, the detection limit is generally determined by the analysis of samples with known concentrations of analyte and by establishing the minimum level at

which the analyte can be reliably detected.

测定---- 对于非仪器分析规程,检测限度的测定方法通常为,对含有已知浓度待分析物的样品进行分析,并确立能够可靠地被检测出来的待分析物的最低水平。

For instrumental procedures, the same approach may be used as for non-instrumental procedures. In the case of procedures submitted for consideration as official compendial procedures, it is almost never necessary to determine the actual detection limit. Rather, the detection limit is shown to be sufficiently low by the analysis of samples with known concentrations of analyte above and below the required detection level. For example, if it is required to detect an impurity at the level of 0.1%, it should be demonstrated that the procedure will reliably detect the impurity at that level.

对于仪器分析规程,可以使用与非仪器分析规程相同的方法。对于提交用于官方药典规程的备选方法,其几乎从来不需要确定实际的检测限度。而是,通过分析含有高于和低于必需的检测水平的、已知待分析物浓度的样品,以显示检测限度足够低。例如,如果必需检测浓度在0.1%的杂质,则应当证明该分析

规程将可靠地检测在这个水平的杂质。

In the case of instrumental analytical procedures that exhibit background noise, the ICH documents describe a common approach, which is to compare measured signals from samples with known low concentrations of analyte with those of blank samples. The minimum concentration at which the analyte can reliably be detected is established. Typically acceptable signal-to-noise ratios are 2:1 or 3:1. Other approaches depend on the determination of the slope of the calibration curve and the standard deviation of responses. Whatever method is used, the detection limit should be subsequently validated by the analysis of a suitable number of samples known to be near, or prepared at, the detection limit.

对于展示出背景噪音的仪器分析规程,ICH文件描述了一个通用方法,用来比较从以下样品测得的信号,这些样品分别为含已知低浓度被分析物的样品和空白样品。这样就确立了能够可靠检测的待分析物的最低浓度。可接受的典型信噪比是2:1或3:1。其他方法取决于校正曲线斜率的测定和响应值的标准差。无论用什么方法,均应该在随后通过分析适当数量的、已知接近或制备于检测限度的样品,来验证检测限度。

QUANTITATION LIMIT定量限度

Definition---- The quantitation limit is a characteristic of quantitative assay for low levels of compounds in sample matrices, such as impurities in bulk drug substances and degradation products in finished pharmaceuticals. It is the lowest amount of analyte in a sample that can be determined with acceptable precision and accuracy under the stated experimental conditions. The quantitation limit is expressed as the concentration of analyte (e.g., percentage, parts per billion) in the sample.

定义---- 定量限度是样品矩阵中低含量物质的定量分析的特性,例如在原料药中的杂质和成品药物中的降解产物。它是在规定试验条件下,能够以可接受的精密度和精确度进行测定的样品中待分析物的最小量。定量限度以样品中待分析物的浓度(例如,百分比、十亿分率)来表示。

Determination---- For non-instrumental procedures, the quantitation limit is generally determined by the analysis of samples with known concentrations of analyte and by establishing the minimum level at which the analyte can be determined with acceptable accuracy and precision.

测定---- 对于非仪器分析规程,定量限度的测定方法通常为对含有已知浓度待分析物的样品进行分析,并确立能够以可接受的准确度和精密度被检测出来的待分析物的最低水平。

For instrumental procedures, the same approach may be used as for non-instrumental procedures. In the case of procedures submitted for consideration as official compendial procedures, it is almost never necessary to determine the actual quantitaion limit. Rather, the quantitation limit is shown to be sufficiently low by the analysis of samples with know concentrations of analyte above and below the quantitation level. For example, if it is required that an analyte be assayed at the level of 0.1 mg per tablet, it should be demonstrated that the procedure will reliably quantitate the analyte at that level.

对于仪器分析规程,可以使用与非仪器分析规程相同的方法。对于提交用于官方药典规程的备选方法,其几乎从来不需要确定实际的检测限度。而是,通过分析含有高于和低于必需的定量水平的、已知待分析物浓度的样品,以显示定量限度足够低。例如,如果必需在0.1mg每片的水平评估待分析物,则应当

证明该分析规程将可靠地这个水平定量待分析物。

In the case of instrumental analytical procedures that exhibit background noise, the ICH documents describe a common approach, which is to compare measured signals from samples wi th known low concentrations of analyte with those of blank samples. The minimum concentration at which the analyte can reliably be quantified is established. A typically acceptable signal-to-noise ratio is 10:1. Other approaches depend on the determination of the slope of the calibration curve and the standard deviation of responses. Whatever method is used, the quantitation limit should be subsequently validated by the analysis of a suitable number of samples known to be near, or prepared at, the quantitation limit.

对于展示出背景噪音的仪器分析规程,ICH文件描述了一个通用方法,用来比较从以下样品测得的信号,这些样品分别为含已知低浓度被分析物的样品和空白样品。这样就确立了能够可靠地定量待分析物的最低浓度。可接受的典型信噪比是10:1。其他方法取决于校正曲线斜率的测定和响应值的标准差。无论用什么方法,均应该在随后通过分析适当数量的、已知接近或制备于定量限度的样品,来验证定量限度。

LINEARITY AND RANGE

线性和范围

Definition of Linearity---- The linearity of an analytical procedure is its ability to elicit test results that are directly, or by a well-defined mathematical transformation, proportional to the concentration of analyte in samples within a given range. Thus, in this section, “linearity” refers to the linearity of the relationship of concentration and assay measurement. In some cases, to attain linearity, the concentration and/or the measurement may be transformed. (Note that the weighing factors used in the

regression analysis may change when a transformation is applied.) Possible transformations may include log, square root, or reciprocal, although other transformations are acceptable. If linearity is not attainable, a non-linear model may be used. The goal is to have a model, whether linear or non-linear, that describes

closely the concentration-response relationship.

线性的定义---- 分析规程的线性是该规程直接地、或通过明确给出的数学转换而间接地,得出与特定范围内的样品中待分析物浓度呈比例关系的测试结果的能力。因此,在此部分,“线性”是指浓度与检验结果之间的线性关系。在某些情况下,为了实现线性,浓度和/或测量数据可以进行转换。(注意:当进行转换时,在回归分析中用到的权重因子可以变化。)虽然其他转换方式也是可以接受的,但是可能的转换包括对数、平方根、倒数。如果无法实现线性,可以使用非线性模型。其目的是得到一个精确描述浓度-响应

值关系的模型,不论是线性还是非线性。

Definition of Range---- The range of an analytical procedure is the interval between the upper and lower levels of analyte (including these levels) that have been demons trated to be determined with a suitable level of precision, accuracy, and linearity using the procedure as written. The range is normally expressed in the same units as test results (e.g., percent, parts per million) obtained by the analytical

procedure.

范围的定义---- 分析规程的范围是分析物的较高浓度和较低浓度(含)之间的区间,已经证实在此区间内,使用该规程进行测定具有适当水平的精密度、准确度、和线性。该范围通常以与该分析规程得到的测试结果相同的单位表示,例如百分比,百万分率等。

Determination of Linearity and Range---- Linearity should be established across the range of the analytical procedure. It should be established initially by visual examination of a plot of signals as a function of analyte concentration of content. If there appears to be a linear relationship, test results should be established by appropriate statistical methods (e.g., by calculation of a re gression line by the method of least squares). Data from the regression line itself may be helpful to provide mathematical estimates of the degree of linearity. The correlation coefficient, y-intercept, slope of the regression line,

and residual sum of squares should be submitted.

线性和范围的确定---- 应在分析规程整个范围内确立线性。线性的确立最开始应该通过目测代表内容物中待分析物浓度的多个信号构成的图表来进行。如果其呈现线性关系,测试结果应该通过适当的统计学方法(例如,以最小二乘方来计算回归线)来确立。来自回归线自身的数据可以用于提供线性程度的数学评估。应该提交其相关系数、Y轴截距、回归线斜率、残差平方和。

The range of the procedure is validated by verifying that the analytical procedure provides acceptable precision, accuracy, and linearity when applied to sample containing analyte at the extremes

of the range as well as within the range.

通过用规程分析含有待分析物的、浓度在范围的极限值上和在范围中的样品,确认该分析规程提供了可接受的精密度、准确度、线性,以进行该规程范围的验证。

ICH recommends that, for the establishment of linearity, a minimum of five concentrations normally be used. It is also recommended that the following minimum specified ranges should be considered:

ICH建议,为了确立线性,通常使用最少五个浓度。其还建议,应考虑下列的最小范围的规定。

Assay of a Drug Substance (or a finished product): from 80% to 120% of the test concentration.

原料药(或成药)的含量测定:供试浓度的80%到120%。

Determination of an Impurity: from 50% to 120% of the acceptable criterion.

杂质的测定:接受标准的50%到120%。

For Content Uniformity: a minimum of 70% to 130% of the test concentration, unless a wider or more appropriate range based on the nature of the dosage form (e.g., metered-dose inhalers) is justified.

对于内容物的均一性:最少供试浓度的70%到130%,除非由于剂型的特性(例如,定量吸入气雾

剂)而支持应用更宽或更适合的范围。

For Dissolution Testing: ±20% over the specified range (e.g., if the acceptance criteria for a controlled-release product cover a region from 20%, after 1 hour, and up to 90%, after 24 hours, the

validated range would be 0% to 110% of the label claim)

对于溶出度检测:在规定范围上±20%(例如,如果一个控释产品的接受标准覆盖了从1小时后20%到24小时后最多90%的区域,则验证区域应该为标签声称值的0%到110%)。

ROBUSTNESS

耐用性

Definition---- The robustness of an analytical procedure is a measure of its capability to remain unaffected by small but deliberate variations in procedural parameters listed in the proce dure documentation and provides an indication of its suitability during normal usage. Robustness may be determined during development of the analytical procedure.

定义---- 分析规程的耐用性是规程文件中列出的操作参数在微小、故意的变更中不受影响的能力的衡量单位,并在日常使用中提供了其适用性的指标。耐用性可以在分析规程的研发中确定。

SYSTEM SUITABILITY

系统适用性

If measurements are susceptible to variations in analytical conditions, these should be suitably controlled, or a precautionary statement should be included in the procedure. One consequence of the evaluation of robustness and ruggedness should be that a series of system suitability parameters is established to ensure that the validity of the analytical procedure is maintained whenever used. Typical variations are the stability of analytical solutions, different equipment, and different analysts. In the case of liquid chromatography, typical variations are the pH of the mobile phase, the mobile phase composition, different lots or suppliers of columns, the temperature, and the flow rate. In the case of gas chromatography, typical variations are different lots or suppliers of columns, the temperature, and the

flow rate.

如果检测结果易受分析条件中的差异影响,则这些差异应当被适当地控制,或应当在规程中加入预防性的陈述。评估耐用性的一个结果就是确立一系列系统适用性参数,以确保不论何时使用,均可维持分析规程的有效性。典型的差异是分析溶液、不同设备、不同分析员的稳定性。对于液相色谱法而言,典型的差异是流动相pH值、流动相构成、不同批号或供应商的色谱柱、温度、流速。对于气相色谱法而言,典型差异是不同批号或供应商的色谱柱、温度、流速。

System suitability tests are based on the concept that the equipment, electronics, analytical operations, and samples to be analyzed constitute an integral system that can be evaluated as such. System suitability test parameters to be established for a particular procedure depend on the type of procedure being evaluated. They are especially important in the case of chromatographic procedures. Submissions to the USP should make note of the requirements under the System Suitability section in

the general test chapter Chromatography <621>.

系统适用性测试基于这个概念,即这些设备、电子仪器、分析操作、供试样品构成了一个完整系统,此系统可以作为整体进行评估。为某个特定规程设定的系统适用性测试参数取决于被评估的规程的种类。对于色谱规程,它们尤其重要。向USP提交的文件应该应该注明在通则色谱法<621>中系统适用性章节下

的要求。

Data Elements Required for Validation

验证所需的数据要素

Compendial test requirements vary form highly exacting analytical determinations to subjective evaluation of attributes. Considering this broad variety, it is only logical that different test procedures require different validation schemes. This chapter covers only the most common categories of tests for which validation data should be required. These categories are as follows: 药典测试的要求差别较大,从高度精确的分析测定到特性的主观评估。考虑到此宽幅差异,则可以理解不同测试规程需要不同的验证计划。此章节仅覆盖了这些需要验证数据的测试中最常见的种类。这些

种类如下:

Category I---- Analytical procedures for quantitation of major components of bulk drug substances or active ingredients (including preservatives) in finished pharmaceutical products.

第一类:对成药中原料药或活性成分(包括防腐剂)的主要组分进行定量测定的分析规程。

Category II---- Analytical procedures for determination of impurities in bulk drug substances or degradation compounds in finished pharmaceutical products. These procedures include quantitative

assays and limit tests.

第二类:对成药中原料药或降解物质中杂质进行测定的分析规程。这些规程包括定量测定和限度测

定。

Category III---- Analytical procedures for determination of performance characteristics (e.g.,

dissolution, drug release).

第三类:对工作特性(例如,溶出度、药物释放)进行测定的分析规程。

Category IV---- Identification tests.

第四类:鉴别测试。

For each category, different analytical information is needed. Listed in Table 2 are data elements that are normally required for each of these categories.

每一个类别均需要不同的分析信息。每个种类通常所需要的数据要素在表2中列出。

Table 2. Data Elements Required for Validation

表2. 验证必需的数据要素

Already established general procedure (e.g., titrimetric determination of water, bacterial endotoxins) should be ▲verified to establish their suitability for use, such as▲USP31 their accuracy (and absence of possible interference) when used for a new product or raw material.

已经确立的通用规程(例如,水分滴定测定、细菌内毒素)应当▲进行确认,以确立在用于新的产品或原料时的适用性,例如▲USP31其准确度(和无可能的干扰因素)。

The validity of an analytical procedure can be verified only by laboratory studies. Therefore, documentation of the successful completion of such studies is a basic requirement for determining whether a procedure is suitable for its intended application(s). Current compendial procedures are also subject to regulations that require demonstration of suitability under actual conditions of use ▲(see Verification of Compendial Procedures <1226> for principles relative to the verification of compendial procedures). ▲USP31 Appropriate documentation should accompany any proposal for new or revised

compendial analytical procedures.

分析规程的有效性可以通过实验室研究来确认。因此,此类研究成功完成的记录文件是确定某个规程是否适用于其预定用途的基本要求。当前的药典规程也要符合相关管理规定,要证实在实际使用条件下

的适用性。▲(见药典规程的确认<1226>,以了解与药典规程确认相关的基本原则)▲USP31适当的记录文件应伴随着任何有关新的或修改过的药典分析规程的方案。

检验方法及方法确认程序

检测方法及方法确认程序 l 目的 为保证检测结果的正确性和有效性,对检测活动中所采用的方法进行有效控制制定程序。 2 范围 适用于检测活动中检测方法的选用,以及检测方法的变更和偏离。 3 职责 3.1 技术负责人的职责 负责授权与客户签立检测合同或协议,批准检测作业指导书等文件,维护本程的有效性。 3.2 检测室负责人的职责 提出本检测部门的执行标准,制定本部门检测活动的检测程序及抽样、检测的职责和活动以及不确定度分析。 3.3 资料管理员的职责 负责对标准、规程及其他技术规范等有效性确认,建立检测标准管理档案。 4 工作程序 4.1 检测方法的选择 4.1.1 为减少检测风险,本检测中心的检测依据首选以下正式颁布的标准。其中优先选用国家标准、行业标准、地方标准:对新旧标准处于过渡期间并均可采用的,优先选择新版标准。 4.1.1.1 国际标用; 4.1.1.2 国家标准; 4.1.1.3 行业标准或政府发布的技术规范; 4.1.1.4 地方标准; 4.1.1.5 企业标用; 4.1.1.6 知名技术组织或科学书籍与期刊公布的方法: 4.1.1.7 制造商指定的方法; 4.1.1.8 自行制定的非标方法。 4.1.2 当老标准己经过期作废时,以上标准应当保证是现行有效的。为此资料管理员首先应当负责检索和收集、查新最新标准及其他技术规范,并按《文件控制程序》保持检测人员所用标准是最新有效版本;其次是每月向检测部门提供中文核心期刊题录,供检测人员参考。当使用外部企业标准检测时,要防止导致可能发生的所有权侵权问题。 4.1.3 当所用标准存在理解、操作等困难对,技术负责人应组织各个检测室负责人编写检测作业指导书,以保证对标准实施的一致性。检测作业指导书应形成正式的书面文件并应经过编制人、审核人和批准人的书面审批手续和保持该文件的

检验方法验证和确认管理规程

目的:明确检验方法的验证和确认的管理规程,确保所采用的检验方法科学、合理,符合检验要求并能有效控制药品的内在质量。 范围:仅适用于本公司对物料、产品的理化检验方法的验证和确认;清洁验证方法的验证。 职责:质量管理部QC QA人员、质量管理部负责人对本规程的实施负责。 内容: 1.方法验证及确认工作职责分工 1.1质量控制部QC负责验证或确认方案的起草、验证或确认工作具体实施以及报告的填写。1.2质量控制部负责人或其指定人员负责验证或确认方案、报告的审核,组织验证或确认工作的实施,对验证或确认工作中出现的问题及时纠正。 1.3质量保证部QA负责验证或确认方案、报告的审核,监督确认工作实施,对确认工作中出现的问题提出改进意见并监督落实。确保检验方法验证或确认程序达到符合性要求,程序被遵照执行,并且方法的预定用途被有效的且以文件记录的数据所支持。 1.4质量管理部负责人负责验证或确认方案及报告的审核批准。 2方法验证 2.1定义:方法验证就是根据检验项目的要求,预先设置一定的验证内容和验证标准要求,并通过设计合理的实验来验证所采用的分析方法是否符合检验项目的要求。 2.2目的:方法验证是证明采用的方法适合于相应检测要求。 2.3适用范围:符合下列情形之一的,应当对检验方法进行验证: (1)采用新的检验方法; (2)检验方法需变更的; (3)米用《中华人民共和国药典》及其他法定标准未收载的检验方法; (4)法规规定的其他需要验证的检验方法。

2.3.1在建立药品质量标准时,应对分析方法中的各检验项目进行完整的验证。 2.3.2当药品生产工艺变更时,制剂的组分变更、原分析方法修订时,可根据变更的内 容决定对分析方法进行部分验证还是完全验证。 2.3.3当原料药合成工艺发生变更时,可能引入新的杂质,杂质检查方法和含量测定方法的专属性就需要进行验证,以证明有关物质检查方法能够检测新引入的杂质,且新引入的杂质对主成分的含量测定应无干扰。 2.3.4当质量标准中某一项目分析方法发生部分改变时,如采用高效液相色谱法测定含量时,检测波长发生改变,则需要重新进行检测限、定量限、专属性、准确度、精密度、线性等内容的验证,证明修订后的分析方法的合理可行。 2.3.5当变更达到一定程度时,则需要完整的验证。如分析方法完全改变,则应按新方法进行完整的验证。 2.4方法验证的一般原则 2.4.1通常情况下,检验方法需进行方法验证。对于仅需按照实验室日常测试操作步骤即可测定的检验项目不需进行方法验证,如外观、崩解时限、密度、重量、pH值、灰分、 装量、硫酸盐等。 2.4.2方法验证的内容应根据检验项目的要求,结合所采用分析方法的特点确定。 2.4.3同一检验方法用于不同的检验项目会有不同的验证要求。 2.5方法验证中需要验证的检验项目 2.5.1检验项目是为控制药品质量,保证药品安全有效而设定的测试项目。根据检验项目的设定目的和验证内容的不同,将需验证的检验项目分类如下: (1)鉴别试验; (2)杂质的限度检查;

(完整版)检验方法验证标准操作规程

标准操作规程STANDARD OPERATING PROCEDURE 目的:建立检验方法验证标准操作规程,规范验证操作。 适用范围:所有检验方法的验证。 责任者:质量保证部、质量控制部 程序: 1、检验方法验证的基本内容 检验方法验证的基本内容包括方案的起草及审批,检测仪器的确认.适用性验证(包括准确度试验、精密度测定.线性范围试验、专属性试验等)和结果评价及批准四个欠的方面。它的基本内容可以用下图表示。 2、检验方法验证的基本步骤 首先是制定验证方案,然后对大型精密仪器进行确认,最关键的一步是检验方法的适用性试验,最后是检验方法评价及批准。 2.1验证方案的制定 检验方法的验证方案通常由质量验证小组提出。根据产品的工艺条件、原辅料化学结构、中间体、分解产物查阅有关资料,提出规格标准,确定检查项目,规定杂质限度,即为质量标准草案。根据质量标准草案确定检查和试验范围,对检验方法拟定具体操作步骤,最后经有关标题检验方法验证标准操作规程共7页第1页 制定人颁发部门GMP办公室编号: SOP--F—004 分发部门质量验证小组、质量保证部新订√替代 审核人批准人生效日期年月日

人员审批方可实施。 2.2大型精密仪器的确认 分析测试中所用的检测仪器一般可分为三类 (1)普通仪器:崩解仪,折光仪、分析天平、酸度计、溶点测定仪、电导仪等: (2)较精密仪器:旋光仪、永停滴定仪、费休氏水分测定仪、自动滴定仪、药物溶出度仪、可 共7页第2页见分光光度计、电泳仪等; (3)大型精密仪器:紫外分光光度计、红外分光光度计、气相色谱仪、高效液相色谱仪、薄层扫描仪等。 为了保证分析测试数据准确可靠,每台检测仪器在投入正式使用之前都应进行确认。检测仪器的确认是检验方法验证的基础,应在其它验证试验开始之前首先完成。检测仪器确认工作内容应根据仪器类型。技术性能而定,通常包括:安装确认、校正、适用性预试验和再确认。2.2.1安装确认 同工艺验证中机械设备一样,仪器安装确认的土要内容包括如下各点: (1)要登记仪器名称.型号。生产厂商的编号、生产日期.生产厂商名称,企业内部的固定资产设备登记号及安装地点; (2)收集汇编和翻译仪器使用说明书和维修保养手册; (3)检查并记录所验收的仪器是否符合厂方规定的规格标准: (4)检查并确保有该仪器的使用说明书。维修保养手册和备件清单: (5)检查安装是否恰当,气、电及管路连接是否符合要求; (6)制定仪器标准操作规程(SOP)和维修保养制度,建立使用记录和维修记录; (7)制定清洗规程;. (8)明确仪器设备技术资抖(图纸,手册,备件清单、各种指南及该机器设备有关的其它文件)的专管人员及存放地点。 除上面提到的内容外,在安装确认方案中对仪器的性能用途应有一概述并记录维修服务单位名称。联系人、电话号码、传真号、银行帐号等,以利于日后的维修保养活动,这对大型精密仪器尤为重要。对于仪器来说,安装确认中的一项重要内容是功能试验。这项工作在安装结

检验方法验证方案(含量测定)

检验方法验证方案 目的:证明所采用的检验方法适于相应的检测要求,具有可靠的准确度、精密度。范围:含量的检定方法的前验证 编定依据:《药品生产质量管理规范》1998年修订版及验证管理办法 职责:验证小组人员 目录 1.概述 2.验证目的 3.职责 3.1验证小组 3.2品质部 3.3化验室 4.验证内容 4.1验证的准备工作 4.2适用性验证 4.2.1准确度试验 4.2.2精密度试验 4.3拟订验证周期 4.4验证结果评定与结论 5.附件

1. 概述 对小容量注射剂的含量测定,本公司采用福林酚测定法,该检验方法具有测量准确、精密度高、专属性强、定量准确可靠、方法简便易行的特点,可满足小容量注射剂含量测定的要求。检验方法标准操作规程。用本方法进行转移因子注射液、胸腺肽注射液的含量测定。 2. 验证目的 为确认对转移因子注射液、胸腺肽注射的含量测定的紫外分光光度法,适合相应的检测要求,特制订本验证方案,进行验证。 验证过程应严格按照本方案规定的内容进行,若因特殊原因确需变更时,应填写验证方案变更申请及批准书,报验证工作小组批准。 验证前,应首先对验证所需的仪器、设备进行验证,对所需仪器、仪表、量具等进行校正。 3. 职责 3.1 验证工作小组 负责验证方案的审批。 负责验证的协调工作,以保证本验证方案规定项目的顺利实施。 负责验证数据及结果的审核。 负责验证报告的审批。 负责发放验证合格证书。 负责再验证周期的确认。 3.2 品质部 负责验证所需仪器、设备的安装、调试,并做好相应的记录。 负责组织验证所需仪器、设备的验证。 负责仪器、仪表、量具等的校正。 负责拟订检验方法的再验证周期 3.3 化验室 负责验证所需的标准品、样品、试剂、试液等的准备。 负责验证方案指定的试验的实施。 负责收集各项验证、试验记录,并对试验结果进行分析后,报验证工作小组。 4. 验证内容 4.1 验证的准备工作 4.1.1 验证所需文件资料 品质部负责提供验证所需的文件资料,包括该检验方法的标准操作规程。以及负责提供验证所需仪器、设备的验证报告以及仪器、仪表、量具等的校正报告。 检查人:日期:

检验方法验证标准操作规程

标准操作规程 STANDARD OPERATING PROCEDURE 目的:建立检验方法验证标准操作规程,规范验证操作。 适用范围:所有检验方法的验证。 责任者:质量保证部、质量控制部 程序: 1、检验方法验证的基本内容 检验方法验证的基本内容包括方案的起草及审批,检测仪器的确认.适用性验证(包括准确度试验、精密度测定.线性范围试验、专属性试验等)和结果评价及批准四个欠的方面。它的基本内容可以用下图表示。 2、检验方法验证的基本步骤 首先是制定验证方案,然后对大型精密仪器进行确认,最关键的一步是检验方法的适用性试验,最后是检验方法评价及批准。 2.1验证方案的制定 检验方法的验证方案通常由质量验证小组提出。根据产品的工艺条件、原辅料化学结构、中间体、分解产物查阅有关资料,提出规格标准,确定检查项目,规定杂质限度,即为质量标准草案。根据质量标准草案确定检查和试验范围,对检验方法拟定具体操作步骤,最后经有关人员审批方可实施。 2.2大型精密仪器的确认 分析测试中所用的检测仪器一般可分为三类 (1)普通仪器:崩解仪,折光仪、分析天平、酸度计、溶点测定仪、电导仪等: (2)较精密仪器:旋光仪、永停滴定仪、费休氏水分测定仪、自动滴定仪、药物溶出度仪、可

见分光光度计、电泳仪等; (3)大型精密仪器:紫外分光光度计、红外分光光度计、气相色谱仪、高效液相色谱仪、薄层扫描仪等。 为了保证分析测试数据准确可靠,每台检测仪器在投入正式使用之前都应进行确认。检测仪器的确认是检验方法验证的基础,应在其它验证试验开始之前首先完成。检测仪器确认工作内容应根据仪器类型。技术性能而定,通常包括:安装确认、校正、适用性预试验和再确认。2.2.1安装确认 同工艺验证中机械设备一样,仪器安装确认的土要内容包括如下各点: (1)要登记仪器名称.型号。生产厂商的编号、生产日期.生产厂商名称,企业内部的固定资产设备登记号及安装地点; (2)收集汇编和翻译仪器使用说明书和维修保养手册; (3)检查并记录所验收的仪器是否符合厂方规定的规格标准: (4)检查并确保有该仪器的使用说明书。维修保养手册和备件清单: (5)检查安装是否恰当,气、电及管路连接是否符合要求; (6)制定仪器标准操作规程(SOP)和维修保养制度,建立使用记录和维修记录; (7)制定清洗规程;. (8)明确仪器设备技术资抖(图纸,手册,备件清单、各种指南及该机器设备有关的其它文件)的专管人员及存放地点。 除上面提到的内容外,在安装确认方案中对仪器的性能用途应有一概述并记录维修服务单位名称。联系人、电话号码、传真号、银行帐号等,以利于日后的维修保养活动,这对大型精密仪器尤为重要。对于仪器来说,安装确认中的一项重要内容是功能试验。这项工作在安装结束,检查合格后即可着手进行。仪器功能试验足在不使用样品的前提下,确认仪器达到设计要求,也可认为是空载试验。例如气相色谱仪的程序升温设定后能否按设定程序执行,溶出仪转速能否达到规定的性能要求。紫外分光光度计的吸收度与透光率的转换是否符合要求。高效液相色谱仪高压泵过压保护是否起作用等,这是检查仪器安装后能达到规定的性能指标。对普通仪器进行的功能试验比较简单,有的除仪器校正外,没有其它特殊的功能试验要做,如酸度计,电导仪,折光仪等。不同的仪器有不同的技术标准,应根据仪器使用说明书的要求进行试验。 2.2.2校正 校正是仪器确认及检验方法验证中的一个重要环节,应当在验证试验以前进行校正。紫外分光光度计校正包括波长校正、吸收度测试、准确度测试、杂散光检查。 气相色谱仪与高效液相色谱仪均要求做系统适用性试验。在规定的色谱条件下测定色谱柱的最小理论塔板数。分离度和拖尾因子,并规定变异系数应不大于2%。 对于化学检验中使用的计量仪器包括容量瓶、移液管、滴定管、分析天平亦均应校正。

检验方法确认方案

检验方法确认方案

目录确认方案 1、概述 2、验证依据 3、验证范围 4、验证目的 5、验证内容 6、验证人员分工

1、概述 单硝酸异山梨酯注射液收载于《中华人民共和国药典》2010年版二部。质量标准中采用高效液相色谱法测定单硝酸异山梨酯的含量,为进一步确认药典方法的可行性及有效性,更好控制产品质量,现对药典方法进行确认。 2、验证依据 《中华人民共和国药典》2010年版二部“单硝酸异山梨酯注射液”项下规定 《高效液相色谱法标准操作规程》(SOP-E-5-009-A01) 《中华人民共和国药典》2010年版二部附录XIXA“药品质量标准分析方法验证指导原则” 3、验证范围 本方案适用于单硝酸异山梨酯注射液检测方法的验证。 4、验证目的 对单硝酸异山梨酯注射液含量测定方法进行确认,以确保检验结果的准确性和可靠性。 5、验证内容 5.1色谱条件与系统适用性试验 色谱条件与系统适用性试验用十八烷基硅烷键合硅胶为填充剂;以甲醇-水(25:75)为流动相;检测波长为210nm。取单硝酸异山梨酯对照品与2-单硝酸异山梨酯对照品适量,加流动相溶解并稀释制成每1ml中各约含5μg的溶液,取20μl注入液相色谱仪,理论板数按单硝酸异山梨酯峰计算不低于3000,单硝酸异山梨酯峰与2-单硝酸异山梨酯峰的分离度应大于2.0。 对照品溶液的制备取单硝酸异山梨酯对照品,用流动相定量稀释制成每1ml约含单硝酸异山梨酯0.1mg的溶液,作为对照品溶液。 供试品溶液的制备精密量取本品适量,用流动相定量稀释制成每1ml约含单硝酸异山梨酯0.1mg的溶液,作为供试品溶液。 5.2 线性和范围 取单硝酸异山梨酯对照品12μl、16μl、20μl、24μl、28μl进样,线性范围1.2μg~2.8μg 按上述色谱条件进样,相应的色谱峰面积为纵坐标(Y),进样量为横坐标(X,μg),绘制标准曲线,计算线性方程,相关系数R。

实验室检验方法的验证和确认

实验室检验方法的验证和确认 1、检验方法验证的基本内容 检验方法验证的基本内容包括方案的起草及审批,检测仪器的确认,适用性验证(包括准确度试验、精密度测定、线性范围试验、专属性试验等)和结果评价及批准四个方面。 2、检验方法验证的基本步骤 首先是制定验证方案,然后对大型精密仪器进行确认,最关键的一步是检验方法的适用性试验,最后是检验方法评价及批准。 1)验证方案的制定 检验方法的验证方案通常由质量验证小组提出。根据产品的工艺条件、原辅料化学结构、中间体、分解产物查阅有关资料,提出规格标准,确定检查项目,规定杂质限度,即为质量标准草案。根据质量标准草案确定检查和试验范围,对检验方法拟定具体操作步骤,最后经有关人员审批方可实施。 2)大型精密仪器的确认 分析测试中所用的检测仪器一般可分为三类 (1)普通仪器:崩解仪,折光仪、分析天平、酸度计、溶点测定仪、电导仪等: (2)较精密仪器:旋光仪、永停滴定仪、费休氏水分测定仪、自动滴定仪、药物溶出度仪、可见分光光度计、电泳仪等; (3)大型精密仪器:紫外分光光度计、红外分光光度计、气相色谱仪、高效液相色谱仪、薄层扫描仪等。 为了保证分析测试数据准确可靠,每台检测仪器在投入正式使用之前都应进行确认。检测仪器的确认是检验方法验证的基础,应在其它验证试验开始之前首先完成。检测

仪器确认工作内容应根据仪器类型。技术性能而定,通常包括:安装确认、校正、适用性预试验和再确认。 校正 校正是仪器确认及检验方法验证中的一个重要环节,应当在验证试验以前进行校正。紫外分光光度计校正包括波长校正、吸收度测试、准确度测试、杂散光检查。 气相色谱仪与高效液相色谱仪均要求做系统适用性试验。在规定的色谱条件下测定色谱柱的最小理论塔板数。分离度和拖尾因子,并规定变异系数应不大于2%。 对于化学检验中使用的计量仪器包括容量瓶、移液管、滴定管、分析天平亦均应校正。适用性预试验 仪器的安装确认完成以后,在其功能试验符合要求的情况下,应用标准品或对照品对其进行适用性检查,以确认仪器是否符合使用要求。例如对熔点测定仪的适用性预试验是采用已知溶点的甲硝唑做试验,测试结果与已知熔点比较。紫外分光光度计可用已知含量的某标准品试验,测得结果与已知数值对比,确定仪器是否符合使用要求。在完成上述各项试验工作的同时,应做好相应的文件记录等资料归档工作,每一台仪器均应有一套完整的档案资料。 再确认 为了确保仪器处于良好的使用状态,对于一台新购买的仪器在确认工作结束以后,应根据仪器的类别。确认的经验制定再确认的计划。再确认的时间间隔和内容要根据仪器类别和使用情况决定,一般是3个月、6个月或1年。仪器再确认的内容通常包括线路连接、附件备品消耗品检查、清洁工作、功能试验、工作日记等,其中重点是安装确认中的功能试验。 3、检验方法的适用性验证

高效液相色检验方法验证方案

型高效液相色谱仪 测定川芎含量检验方法验证方案 文件编号 S-YF-013(01) 起草人崔英南日期 2012年08月26日审核人日期 2012年08月31日批准人李立新日期 2012年08月31日生效日期 2012年09月01日 验证项目申请单

文件编号: 验证项目计划书文件编号:

验证方案审批表吉

目录

1再确认目的 2再确认范围 3再确认责任 4内容 概述 再确认内容 再确认小组 4.2.2 预确认 4.2.3 安装确认 4.2.4 运行确认 4.2.5 性能确认 4.2.6 结果分析与评价4.2.7 再确认周期

目的 确认经设备确认高效液相,按药典检验方法测定生产品种含量,验证其检验结果科学性、准确性、精密性等,满足检验结果正确性需要,有效控制产品质量。 提供必要的文件以证实本设备的操作与所预期的完全一致。 根据本方案的验证,确认按检验操作规程操作,能有效的保持本设备于确认状态下,能稳定地、恒定地达成其所预期的功能。 范围 质量标准、检验操作规程文件的汇集。 验证设备用于含量测定检验方法的准确性在标准范围内 验证设备用于含量测定检验方法的精密度可靠性 验证设备用于含量测定检验方法,在设计的范围内,测试结果与供试品中被测物尝试直接呈正比关系的程度。 验证设备用于含量测定检验方法具有专属性。 验证设备用于含量测定检验方法在达到一定精密度、准确度和线性时,其测定值高低限在可控范围内。 验证设备用于含量测定检验方法的耐用性。 责任 质量管理部负责验证方案的起草,申请审批,验证过程的监督、资料的存档,再确认方案的执行及再确认结果的评估。 化验室负责实验的操作,原始记录、报告的填写。

检验方法的验证及确认-精选.pdf

检验方法是指实验室用于实施检验检测工作所依据的标准检验方法和技术规范。检验方法是实验室实施检验工作的主要依据,是开展检验检测工作所必须的资源,如果方法及程序不同 就会造成结果不同。本文就来聊聊如何对检验方法进行确认。文章为原创大赛往期作品回顾, 在此仅作为对大家的启发之用。欢迎批评指正。 <<实验室资质认定评审准则>> 条款中规定:“实验室应确认能否正确使用所选用的新方法。 如果方法发生了变化,应重新进行确认。实验室应确保使用标准的最新有效版本。”在条款中也有相应的规定。 实验室采用的检测方法包括样品的抽取、处理、运输、存储和制备等各个环节,确认时应当 记录确认所获得的结果、使用确认的程序、确认对方法是否适合于预期的用途等,必要时还应包括不确定度和分析数据的统计学处理技术。 ? 下面谈谈就方法发生了变更时或颁布新标准时,对方法如何进行确认: 1.在首次对外出具数据之前应确认(证实)标准方法已被正确的运用。 2.标准方法发生了变化应重新确认。 3.对标准方法定期清理或者查新,以确保最新有效版本。 一、检测方法的选择及使用要求 实验室资质认定(或认可)现场考核时确定的检测项目的依据是国家标准、行业标准和地方标 准。所以说,当没有国际、国家、行业、地方规定的检验方法时,实验室应尽可能选择已经 公布或由知名的技术组织或有关科技文献或杂志上公布的方法,但应经实验室技术主管确 认。如是在实验室计量认证或认可批准业务范围内,因客户的特殊要求而发生的情况,其检验结果和报告上应有明确的说明。 另外需要使用非标准方法时,这些方法应征得委托方同意,并形成有效文件,使出具的报告为委托方和用户所接受。这是指必须在实验室计量认证或认可批准业务范围内使用,所谓有效文件是指甲乙双方对使用非标准方法检测达成协议,一般来说应有双方签字盖章,也可以在检测委托(协议)书上注明,实验室在检测报告中也必需加以说明。 因此,在检测方法的选择上,优先使用国家标准,然后是行业标准、地方标准,非标准方法 仅限于委托方同意才使用。 对于实验室完成的每一项或每一系列检验的结果,均应按照检验方法中的规定,准确、清晰、明确、客观地在检验证书或报告中表述,应采用法定计量单位。证书或报告中还应包括为说 明检验结果所必需的各种信息采用方法所要求的全部信息。除上述明确的要求外,检测报告中必需有检测数据和结论。 所以说,检测方法选择的核心就是方法有效性,要特别注意的是:要使用最新有效版本的方法。

无菌检验验证方案样本

类别:编号: 部门:页码: 无菌检验方法验证 版次:□新订口替代: ________________ 制定人: ___________________ ____________ H H 日审批会签: _____________________________________________

1.1 确认所用的检查方法适用于一次性活检钳的无菌检查。 1.2 确认检查结果的准确性、可靠性、重复性和可操作性及检查方法的完整 性。 2. 验证范围 适用于我公司生产的一次性活检钳无菌检验。 3. 检验依据 《中国药典》附录无菌检查法 ISO11737-2: 医疗器械的灭菌微生物学方法第一部分: 确认灭菌过程的无菌试验 GB/T14233.2- 医用输液、输血、注射器具检验方法第2部分: 生物学试验方法 4. 验证器材 4.1 检验环境: 无菌检查应在环境洁净度10000 级下的局部100 级的单向流空气 区域内进行操作。 4.2 设备: 医用净化工作台、生物安全柜、无菌检查膜过滤器、电动吸引器、 电热干燥箱、霉菌培养箱、数显生化培养箱、压力蒸汽灭菌器、电子天平、pH 计、冰箱、恒温水浴锅、显微镜等。 4.3 培养基及稀释液: 硫乙醇酸盐流体培养基、改良马丁培养基、pH7.0 氯化钠- 蛋白胨缓冲液、0.1% 蛋白胨水溶液、营养琼脂。 4.4其它实验材料:微孔滤膜(孔径w 0.45um,直径约50mm)、无菌过滤杯、无 菌剪刀、无菌镊子、无菌钳子、无菌手套、吸管(1ml和10ml)、酒精灯、三角烧瓶、接种环、培养皿。

5.1 原理: 活检钳的形状为不溶物, 为微生物转移更彻底, 特选用无菌检查法中的 薄膜过滤法。 5.2 设备器材: 验证中所用器材、设备已经过国家计量单位鉴定合格并有鉴定证书。 5.3 培养基: 验证中所用培养基以经过培养基灵敏度实验检测合格。 5.4 操作步骤: 5.4.1 供试品的取样按照GB/T 2828.1- 相关规定进行逐批取样。 5.4.2 将所需物品, 供试品表面消毒, 经过传递窗, 紫外线照射半小时. 无菌室紫 外线消毒半小时。 5.4.3 操作人员用洗手液、自来水清洗双手, 关闭紫外灯, 换拖鞋, 脱外衣放入衣 柜, 穿洁净白大衣, 进入缓冲间, 再用洗手液、纯化水清洗双手, 用75% 乙醇对手进行消毒, 穿戴无菌衣、帽、口罩、手套等。 5.4.4 进入菌检室, 打开医用洁净工作台风机, 运行至少15分钟以上。 5.4.5 将所需物品由传递窗取出, 两只消毒液桶分别放置于菌检洁净工作台一侧, 其余物品放置于传递窗一侧的方形桌上, 剥去牛皮纸外包装。 5.4.6 医用洁净工作台内点燃酒精灯。打开3个养琼脂平板, 置于医用洁净工作 台的不同位置。 5.4.7 取供试品, 在医用洁净工作台内, 打开包装袋, 小心将供试品取出, 将其剪成 约10cm的小段,浸入500ml 0.1%无菌蛋白胨水溶液中,充分振摇作为供 试液。 5.4.8 将供试液平均转入三个薄膜过滤器的滤杯中, 开启电动吸引器开关进 行过滤,用pH7.0蛋白胨-氯化钠缓冲液每次100ml冲洗滤膜三次,用平口镊子夹取滤膜(过程保持滤膜的完整性) , 一张转移到100ml 改

检验方法验证规程

目的:检验方法验证的目的是证明采用的方法适合于相应检测要求。 适用范围:在制定药品质量标准时所采用的检验方法应验证,药物生产方法变更、制剂组分变更、原检验方法进行修订时,检验方法应进行再验证。 责任者:化验室、研究开发实验室 内容: 1.验证项目药品检验方法包括化学检验、生物测定和仪器分析三种。验证项目应包括: 鉴别试验; 杂质定量或限度检查; 制剂中其他成分(如降解产物、防腐剂等)测定; 有效成分含量测定; 溶出度释放度检查中溶出量的测试方法。 2.一般步骤 2.1方案的起草及审批 通常由研究开发实验室提出,检验实验室会签,根据产品工艺条件、原辅料化学结构、中间体、分解产物查阅有关资料提出规格标准,确定检查项目,规定杂质限度和操作步骤,并经有关领导审批方可实施。 2.2仪器的确认验证过程中所用的仪器设备均应校验,对于新的大型

精密仪器应进行确认,确保测试数据的准确可靠。大型精密仪器应制定确认方案,经安装确认、运行确认符合要求,有关领导批准确认报告后方可投入使用。 2.3适用性试验适用性试验内容包括:准确度试验、精密度测定、线性范围试验、选择性试验、检测限等。 2.3.1准确度试验准确度是指测量值与真值接近的程度,测量值与真值愈接近,测量值的误差愈小,测量就愈准确。在准确度试验中可用对照试验、回收试验和空白试验三种方法。准确度通常用回收率表示。 原料含量测定方法的准确度一般用已知含量的对照品或标准品作样品,以所用的方法对它进行定量测定,从分析结果与标准样品或纯净物的含量差值就可知道误差。 制剂含量测定方法的准确度一般用已知含量的原料和处方中相应的辅料按比例模拟配制成制剂进行测定。 杂质定量测定方法的准确度一般用加入已知量杂质进行测定,应能明确证明单一杂质或杂质总量相当于主成分的重量百分比。 在规定范围内,至少用9次测定结果进行评价,如制备3个不同浓度的样品,各测定3次,或把被测物浓度当作100%,用至少测定6次的结果进行评价。 2.3.2精密度测定精密度系指在规定的测试条件下,用同一方法对某一成份进行多次测定,所测得值彼此符合的程度,所以也称重现性,测定值彼此愈接近,测量值的偏差愈小,测量就愈精密。 精密度通常用相对标准偏差表示。 在规定的范围内至少用9次测定结果进行评价。 2.3.3线性范围试验在检验过程中取样量或样品浓度是允许在一定范围内变化的,测定的结果也应随取样量或样品浓度成正比的变化,这样的检验方法才能达到准确度和精密度的要求。取样量在一定范围内变化时,测得含量的结果也成正比的变化,这样的取样范围称之为线性范围。 线性范围的测试通常精密配制一系列供试样品(至少5份)进行测定,以测得的响应信号作为被测物浓度的函数,用最小二乘法进行线性回归。

微生物检验方法验证方案

微生物限度检查方法(平皿法) 验证方案 目录 一、验证方案的制定 二、验证方案的起草与审批 三、微生物限度检查方法(平皿法)验证方案 1.验证目的和原理 2.验证方法步骤 3.试验实施 3.1试验前的准备 3.2验证试验操作 3.3试验结果 4.验证结果评价分析

5.附件 微生物限度检查方法(平皿法)验证文件一、验证方案的制定 二、验证方案的起草与审批 1验证方案的起草

2.验证方案的审核与批准 验证方案审核人:审核日期:年月日验证方案批准人:批准日期:年月日三、微生物限度检查方法(平皿法)验证方案 1.验证目的和原理 1.1 验证目的 为确认所采用的方法适合于该药品的细菌、霉菌、酵母菌数的测定,特制定本方案。验证过程应严格按照本方案规定的内容进行,若因特殊原因确需要变更时,应报验证委员会批准。 1.2 原理 通过比较试验4组中试验菌的恢复生长结果来评价整个检验方法的准确性、有效性和重现性。 2.验证方法步骤 2.1验证前的准备进行微生物限度检查方法(平皿法)验证前,所有的平皿和稀释剂都应该严格按照相关的灭菌程序消毒,以确保其对试验的结果没有影响。试验菌应包括G-、G+、酵母菌和霉菌类微生物以基本覆盖样品中可能存在的微生物。 2.2验证试验的操作计划用3个不同批号产品按照微生物限度检测方法进行平行试验,通过计算回收率来判断微生物限度检查方法是否对产品有影响。 2.3试验结果可接受标准用标准菌株评价方法“尿素维生素E乳膏的微生物限度检查”对检品中微生物的抑制性,试验结果应显示3次独立的平行试验中,稀释剂对照组的菌回收率应不小于70%,试验组的回收率也不低于70%。 3.试验实施 3.1试验前的准备 3.1.1主要仪器设备:高压蒸汽灭菌器、恒温烘干箱、净化工作台、生物安全柜、

方法学验证方案

***含量测定 方法学确认方案日期:2016年1月

验证方案审查与批准 您下面的签字表明您已审阅此份验证方案并同意实施。

目录 1 目的 (4) 2 范围 (4) 本方案适用于*****药业股份有限公司齐墩果酸片含量测定方法的确认。 (4) 3 验证机构与职责 (4) 4 定义 (5) 5 参考文件 (5) 6 风险因素分析 (5) 7 验证准备 (6) 8 检测方法的描述 (6) 8.1 药品与试剂的准备 (6) 9 验证实施 (8) 11 确认结果评定与结论 (14) 12 附录目录 (14)

1 目的 对苦参膜中的含量测定检测方法进行确认,确保方法的可行性,以便为有效控制苦参膜的含量提供依据。 2 范围 本方案适用于*****药业股份有限公司齐墩果酸片含量测定方法的确认。 3 验证机构与职责 3.1验证小组成员 3.2 职责 3.2.1验证小组组长职责 3.2.1.1保证确认方案及各种检查表的起草。 3.2.1.2保证在执行前完成对确认方案及各种检查表的审核和批准。 3.2.1.3负责对确认小组成员进行本方案的培训。 3.2.1.4保证完全按照确认方案实施。 3.2.1.5确保能及时发现偏差,并按照已经达成一致的偏差处理方法对其进行记录、纠 正、调查和最终确认。 3.2.1.6确保确认报告的生成、审核和批准。 3.2.2QA职责 3.2.2.1执行前完成对确认方案及各种检查表的审核。 3.2.2.2负责确认过程的监控和检查,保证确认方案的实施,参与确认结果评价。 3.2.2.3参与确认偏差的调查、处理、和评估。 3.2.2.4确认过程中,如有变更,保证按《变更处理程序》执行。

检验方法的验证、确认步骤及详细计算方法

检验方法的验证、确认步骤及详细计算方法 一、检验方法验证的基本内容 检验方法验证的基本内容包括方案的起草及审批,检测仪器的确认。 适用性验证(包括准确度试验、精密度测定、线性范围试验、专属性试验等)和结果评价及批准四个的方面。 二、检验方法验证的基本步骤 首先是制定验证方案,然后对大型精密仪器进行确认,最关键的一步是检验方法的适用性试验,最后是检验方法评价及批准。 1、验证方案的制定 检验方法的验证方案通常由质量验证小组提出。根据产

品的工艺条件、原辅料化学结构、中间体、分解产物查阅有关资料,提出规格标准,确定检查项目,规定杂质限度,即为质量标准草案。 根据质量标准草案确定检查和试验范围,对检验方法拟定具体操作步骤,最后经有关人员审批方可实施。 2、大型精密仪器的确认 分析测试中所用的检测仪器一般可分为三类: A、普通仪器:崩解仪,折光仪、分析天平、酸度计、溶点测定仪、电导仪等: B、较精密仪器:旋光仪、永停滴定仪、费休氏水分测定仪、自动滴定仪、药物溶出度仪、可见分光光度计、电泳仪等; C、大型精密仪器:紫外分光光度计、红外分光光度计、气相色谱仪、高效液相色谱仪、薄层扫描仪等。

为了保证分析测试数据准确可靠,每台检测仪器在投入正式使用之前都应进行确认。 检测仪器的确认是检验方法验证的基础,应在其它验证试验开始之前首先完成。 检测仪器确认工作内容应根据仪器类型。技术性能而定,通常包括:安装确认、校正、适用性预试验和再确认。 3、校正 校正是仪器确认及检验方法验证中的一个重要环节,应当在验证试验以前进行校正。紫外分光光度计校正包括波长校正、吸收度测试、准确度测试、杂散光检查。 气相色谱仪与高效液相色谱仪均要求做系统适用性试验。在规定的色谱条件下测定色谱柱的最小理论塔板数。分离度和拖尾因子,并规定变异系数应不大于2%。

检验方法验证的类型及基本要求

检验方法验证的类型及基本要求 (一)概述 方法验证的目的是证明所采用的方法达到相应的检测要求。由于分析性质的差异,本节中所讨论的验证内容不适用微生物分析方法。 验证的内容主要包括准确度、精密度、专属性、检测限、定量限、线性、范围、粗放性和耐用性9个方面。药典收载的方法一般比较成熟,需验证的内容与新开发的检验方法有很大差异,美国药典中明确规定其所收载的方法需做系统适应性试验,这即是美国药典对方法验证的要求。某一方法需到底须进行哪些项目的验证,应根据实际情况而定,并不是所一的方法都必需进行以上9个方面的验证试验。方法验证的范围,一般来说,可分为以下3种情况区别对待。 1、对于直接引用有法定依据的方法,如药典标准和部颁标准,仅做系统适应性试验即可。但若将法定方法用于测定新药,或将某一品种的法定方法用于另一品种,就需进行系统的方法验证。 2、对于已在一实验室验证过但需在另一个实验室使用的分析方法,可采用对照试验法。即取同一批样品,按此方法在两实验室分别进行检验,将结果进行比较(如用t检验法计算),判断是否有显著性差异。这特别适用于大公司(包括跨国公司)的情况。母公司完成了系统的方法验证工作,子公司实验室均可用结果对照的方法进行判断,节省了大量人力、物力。国外称这种做法为“技术转移”(Technical transfer)。 3、其他分析方法可分为4种类型,验证要求可参见下表 不同分析方法的验证要求 验证项目类型 类型I 类型II 类型III 类型IV 定量测定限度试验 准确度要求要求 * * —— 精密度要求要求——要求—— 专属性要求要求要求 * 要求 检测限————要求 * —— 定量限——要求—— * —— 线性要求要求—— * —— 范围要求要求 * * —— 注:“——”表示不坐要求;“*”表示需根据实验特性决定是否坐要求。 类型I指用于测定原料药中主要成分或制剂中活性组分(包括防腐剂)的定量分析方法。类型II指用于测定原料药中杂质或制剂中降解产物的分析方法,包括定量分析和限度试验。类型III指用于测定性能特性(如溶解度、溶出度)的分析方法。 类型IV指鉴别试验。 (二)验证的内容及基本要求 1. 准确度 准确度是指用该方法测定的结果与真实值接近的程度,一般用回收率表示。准确度的测定至少要区方法范围内地个浓度级别,每个浓度级别至少要测定3次。如某方法的范围是80%~120%,则应取80%、100%、120% 3个浓度,每个浓度测定3次,计算9个测定结果的回收率及相对标准偏差,回收率及相对标准偏差均应在规定限度之内。 (1)原料药含量分析可通过分析已知纯度的对照品或样品进行测定,或用本法所得结果与另一验证的方法所得结果进行比较。 (2)制剂中各组分的含量分析按制剂处方取适量各组分进行有机物混合得有一混合物

检验方法验证、检验方法确认实例(2010年版GMP)

检验方法确认报告 检验方法确认--产品名称确认报告编号 R-TS-VP-4001-00 人工牛黄甲硝唑胶囊 批号:20151201、20151202、20151203 验证工作组 工作组职务姓名部门及职务职责组长黄汉新质量负责人/质量受权人负责确认方案及报告的批准 副组长曾凤敏质量部QC组长负责确认方案起草、实施、汇总报告及培训工作副组长胡建新质量部QA组长审核确认方案、审核验证报告并协调工作组员刘红华质量部QC 参加确认方案实施、汇总报告工作

目录 1. 概述 2. 确认目的和范围 3. 组织及职责 4. 确认起止日期 5. 方法确认所需要的仪器设备及相关文件的确认 6. 方法确认所需要的对照品、原辅料、检验样品的确认 7.确认项目和确认方法、确认结果 7.1【鉴别(1)】人工牛黄薄层色谱鉴别方法确认 7.2【鉴别(2)】甲硝唑紫外光谱鉴别方法确认 7.3【鉴别(3)】人工牛黄胆红素液相色谱鉴别方法确认7.4甲硝唑含量测定方法专属性确认 7.5甲硝唑含量测定方法线性关系与线性范围确认 7.6甲硝唑含量测定方法准确度确认 7.7甲硝唑含量测定方法精密度确认 7.8甲硝唑含量测定方法耐用性确认 7.9胆红素含量测定方法系统适用性确认 7.10胆红素含量测定方法专属性确认 7.11胆红素含量测定方法线性关系与线性范围确认 7.12胆红素含量测定方法准确度确认 7.13胆红素含量测定方法精密度确认 7.14胆红素含量测定方法耐用性确认 8.三批产品按本检验方法检验的结果确认 9.偏差与漏项控制 10.确认报告会审

1. 概述 我公司生产的品种人工牛黄甲硝唑胶囊,执行国家药监局颁布的法定药品标准,标准号为:WS-10001-(HD-0204)-2002。本公司前身(原广东华卫药业有限公司)按该标准生产、检验人工牛黄甲硝唑胶囊已有多年的历史。 根据GMP(2010版)第二百二十三条规定,对收入药典和其它法定标准的分析方法,应通过检验方法确认来证明该方法在本实验室条件下的适用性。故本公司依照法定标准WS-10001-(HD-0204)-2002以及《中国药典》2015版四部附录9101:药品质量标准分析方法验证指导原则的规定,制定本检验方法确认方案,由质量部按制定的方法进行试验,根据试验结果判断检验方法在本公司是否适用。 本产品的微生物限度检查方法验证,另行制定验证方案进行验证,不包括在本次确认。 2. 确认目的和范围 确认该产品的检验方法在本公司检验室的适用性,保证检验结果的可靠性。 本确认方案采用3批按GMP要求组织生产的人工牛黄甲硝唑胶囊,进行检验方法的确认。确认项目包括【鉴别】、【甲硝唑含量测定】、【胆红素含量测定】等。 3.组织及职责 3.1确认方案和确认报告的起草、审核、批准 确认方案由质量部QC组负责起草,由质量部审核,最终由质量负责人批准。确认方案实施完成后,由QC组负责汇总各个项目确认的结果、撰写报告,由质量部审核,最终由质量负责人批准报告。 3.2确认方案的培训 确认方案在经质量负责人批准后,由QC组组长对本次确认实施的相关人员组织培训工作,并将该次的培训记录归档。 3.3确认方案实施过程中的变更和偏差 确认方案实施过程中如有变更和偏差,质量负责人应当组织进行评估并采取相应的控制措施。 3.4 确认工作小组成员表 姓名部门及职务职责 黄汉新质量负责人/质量受权人负责确认方案及报告的批准 曾凤敏质量部QC组长负责方案制定、实施、报告及培训工作 胡建新质量部QA组长审核确认方案、审核确认报告并协调工作 刘红华质量部QC 参加确认方案实施、汇总报告工作 4. 确认起止日期 用于本次检验方法确认的三批产品是人工牛黄甲硝唑胶囊 批号:、、 实施确认工作的起止时间是:~

分析方法验证与确认管理规程完整

3 定义 3.1 检验方法验证:证明采用的方法适用于相应检测要求。 3.2 检验方法确认:证明使用法定方法在目前实验室条件下是否能获得可靠结果,是否适用于相应的检测工作。在本质上和验证一样,但不一定是验证项目的全部。 3.3 药典方法:经过国家药监部门批准的药典收载的质量标准和检验方法 3.4 法定方法:法定方法包括药典方法、国标方法等。 3.5 准确度:是指用该方法测定的结果与真实值或参考值接近的程度,一般用回收率表示。 3.6 精密度:是指在规定的测试条件下同一个均匀供试品经多次取样测定所得结果之间的接近程度。 3.7 重复性:在相同条件下,由同一个分析人员测定所得结果的精密度称为重复性。 3.8 中间精密度:在同一个试验室,不同时间由不同分析人员用不同设备测定结果之间的精密度称为中间精密度。 3.9 重现性:在不同实验室由不同分析人员测定结果之间的精密度称为重现性。 3.10 专属性:是指在其他成分(如杂质、降解产物、辅料等)可能存在下,采用的方法能正确测定出被测物质的特性。 3.11 检测限:是指供试品中被测物能被检出的最低量。 3.12 定量限:是指供试品中被测物能被定量测定的最低量。 3.13 线性:是指在设计围,测试结果与试样中被测物浓度直接成正比关系的程度。3.14 围:是指能达到一定精密度、准确度和线性,测试方法适用的高低浓度或量的区间。 3.15 耐用性:是指在测定条件有小的变动时,测定结果不受影响的承受程度。 4 职责 4.1 标准验证岗 4.1.1 提升现行质量标准工作时,对研究后确定的标准草案进行检验方法验证工作,以确保检验方法的适用性、科学性。 4.1.2 对技术部移交的新品质量标准草案进行确认,以确保检验方法适用性、科学性。 4.1.3 对技术部移交的新品应研究建立设备清洁验证残留物检验方法,并进行方法学验

微生物限度检查方法验证方案

微生物限度检查方法验证方案 1.目的: 为确认所采用的方法适合于该药品的微生物限度检查,包括细菌、霉菌及酵母菌计数和控制菌检查,特制定本验证方案,通过比较试验菌的恢复生长结果,来评价整个检验方法的准确性、有效性和重现性,以确认供试品在该实验条件下无抑菌活性或其抑菌活性可忽略不计,所采用的方法适用于该品种的微生物限度检查。 验证过程应严格按照本方案规定的内容进行,若因特殊原因确需变更时,应填写验证方案修改申请并报验证领导小组批准 2.范围: 本验证方案适用于微生物限度检查方法的验证。 3.规范性引用文件: 根据《中国药典》2010年版二部附录Ⅺ J 微生物限度检查法的要求,由于某些供试品具有抗菌活性,在建立微生物检查方法或产品的组分发生改变或原检查法的检验条件发生改变时,可能影响检验结果的准确性,必须对供试品的抑菌活性及测定方法的可靠性进行验证。 4.验证实施: 4.4.1 试验前的准备: 4.4.1.1 试验用具的准备:将试验需用的试管、刻度吸管、薄膜过滤器、滤膜(孔径0.22um、直径50mm)、平皿、空三角瓶、称量纸等,用牛皮纸包扎好后,放于湿热灭菌器中,在121℃,灭菌30 min,在3天内使用。 4.4.1.2试验用培养基的制备:取适用性检查合格的营养琼脂培养基、玫瑰红钠琼脂培养基、营养肉汤培养基、胆盐乳糖培养基(BL)、改良马丁琼脂培养基、4-甲基伞形酮葡糖苷酸培养基(MUG)等脱水培养基,按照相应的配制说明,用纯化水配制、分装后,在2小时内,放于湿热灭菌器中,在121℃,灭菌15 min,在3周内使用。 4.4.1.3试验用稀释剂/缓冲液、冲洗液的制备:取在有效期内的试剂,按照相应的配制方法,配制pH7.0无菌氯化钠-蛋白胨缓冲液、0.9%无菌氯化钠溶液、0.05%(ml/ml)聚山梨酯80的0.9%无菌氯化钠溶液等,用纯化水配制,加热使溶,过滤,分装,在121℃,灭菌15 min,在3周内使用。 4.4.2 试验菌的制备和稀释:

相关文档
最新文档