在线水质分析仪说明书

目录

1.操作说明 (3)

2.G::SYSTEM简介 (4)

3 常用术语 (5)

4.测量 (6)

4.1光谱测量原理 (6)

4.2 功能检查/参考测量 (6)

4.3 探头的安装 (7)

5.安装 (8)

5.1产品清单 (8)

5.2 组装 (8)

5.3连接压缩空气清洗装置 (8)

5.4探头的安装 (9)

6 操作 (10)

6.1 con::lyte的启动 (10)

6.2 探头的搜索和初始化 (11)

7 测量显示/主要菜单 (12)

7.1 各按键的功能 (12)

7.2读数和信息显示 (12)

7.3 主菜单/菜单项 (13)

8 测量/CON::LYTE操作 (15)

8.1自动 (15)

8.2 手动操作 (15)

8.3 运行日志和数据 (16)

8.4 settings(测量参数设置) (16)

8.4.1 Settings \ s::canpoint (16)

8.4.2 Settings \ Measurement (16)

8.4.3 Settings \ Cleaning (17)

8.4.4 In-/Output(电源和中继界面) (17)

8.4.5 In-/Outputs \ mA Output (18)

8.4.6 In-/Outputs \ Relays (Fault Relay) (18)

8.4.7 In-/Outputs \ Reset settings (19)

8.5 Calibration (19)

8.5.1 Calibration \ Global calibration (19)

8.5.2 Calibration \ Local cal. (19)

8.5.3 Calibration \ function control (20)

8.6 Information (20)

8.7 Extra (20)

9 附件 (21)

9.1 多功能玻片 (21)

9.2 安装棒 (21)

9.3旁路器具 (23)

10 运行日志消息 (25)

11 软件的下载说明(CON::LYTE) (28)

12 联系地址 (28)

1.操作说明

通过购买s::can G::system 在线水质分析仪,您会获得一种易于操作,应用围广的高科技测量产品。

为了可以充分发挥该产品的各种性能,您需要熟悉整个测量系统:例如滤波频谱仪传感器探头(carbo::lyser,nitro::lyser or multi::lyser),控制器(con::lyte)和测量技术相关背景等知识背景。设计本手册的目的就是为了使您能够熟悉整个G::system系统。

请注意本手册可以在随产品附带的CD-ROM光盘中找到。本手册在光盘中是以MS-WORD格式提供,可以方便的使用超文本连接来浏览手册。也就是说,您可以直接点击超(例如章节号)以跳至该章节。您也可以使用MS-WORD提供的Web导航工具跳转到其他位置。所有超都用蓝色标记:[Reference].所有使用斜体和下滑线的文字都可以在控制器中的显示中找到。

在下面的第[3]、[4]部分将会给出常用术语的解释以及系统的免维护特性的介绍。如果想了解该测量系统的各个部件、安装信息和开机操作,请察看第[5]、[6]部分。

第[7]、[8]部分将介绍如何通过控制器来操作监视系统,该部分是本手册容最多的。

第[9]部分将介绍可从s::scan选购的测量附件和安装附件。

第[10]部分提供了一些您可能会遇到的问题的解决方法。

第[11]部分将会一步一步的描述如何通过USB联接来升级控制器(con::lyte)软件。

在第[12]部分提供了我们的联系地址

在技术文件中提供了产品的所有的数据和规格。(“submersible s::scan spectrometers”and”s::can controllers”)

祝您使用s::can产品愉快!

如果您有任何疑问,请立即与您的经销商联系。或者直接给我们发。

想了解我们详细信息,请察看最后一页。

2.G::system简介

由滤波频谱仪探头和控制器组成的G::system是一种在标准应用中安全易操作的设备。该产品的重要特性在下面提到的过程能力:

简洁友好的操作

精心设计的测量结果显示

高安全性和高稳定性

置标定

自动清洗装置,基本免维护

下面的关键字将会告诉我们如何方便、安全、可高的进行每天的测量工作:

用户可以自定义测量时间以获取连续时间测量序列

自动浊度校正可以补偿在测量可溶性物质的过程中不溶性物质造成的影响

智能评估算法可以优化测量参数以适应介质的改变

自动检测程序确保系统的高可靠性

光谱算法可以准确的量化独立于背景矩阵的物质个体和物质总体

所有的设置已经根据实际应用在通用算法的框架中的得以调整。因此,用户可以直接开始测量而不必花费很多时间来设置各种参数

现场标定

自动清洗装置可以使设备提供长达数月的可靠数据

过程控制系统的界面可以灵活的配置

3 常用术语

本章介绍了一些常用术语。了解该术语有助于理解G::system测量系统。下面的列表是按字母表排列的。在解释中的斜体字本身也是本章介绍的书语。

吸收(absorption):吸收是与物质的浓度成比例的:浓度越高,光吸收越多。每种物质都吸收与自己典型波长相同的光。这应用在当从FP中计算个别参数时,所要求的算法储存在通用标定中。每个s::can探头都采用256种波长的光来测量吸收。

Abs/m 通过直接比较不同测量路径的结果所获得的每米的吸收值。如果浓度为常量,吸收随测量路径的长度直线的改变。

Carbo::lyser: s::can滤波频谱传感器探头可以测量两种浓度参数(FTUeq和TSSeq)和有机碳(CODeq和TOCeq)

Con::lyte:特用于s::can滤波频谱仪传感器探头carbo::;yser,nitro::lyser 和multi::lyser 以区别于con::lyte2(2参数)和con::lyte4(4参数)

控制器:或者叫做本地控制器。所有用于操作s::can探头的计算器都可在该单元上显示。例如:PC,膝上/笔记本电脑,con::stat,con::lyte等

衰减(extinction):同吸收(absorption)

Fp:在一个特定的测量时间,取决于波长(nm横轴)的吸收光谱(Abs/m纵轴)的代表。物质在特定的波长上吸收光。Fp由测量时间所有物质在测量介质中的吸收所组成。Fp使用通用标定来计算参数。在使用滤波频谱传感器探头时,fp 是测量的基础。

功能性检查:参考测量和测量窗口的软件检查。如果功能性检查正常,则说明测量窗口未堵塞,参考测量正常。如果窗口被堵塞或者使用一年后应该进行功能性检查。

本地标定:当探头安装好以后,借助于实验分析对比数据而对测量介质的特定组成而进行的标定。因为不能与实际污水的特定组成相对应,人造污水或者标准等标定方法不可用。而且基于通用标定,经常在实验室确定的浓度与光谱测量的参数建立一个线性连接。测量介质的组成由优于本地标定的采样来确定。

通用标定:基于测量介质(例如饮用水,污水)而对滤波频谱仪传感器探头所做的调整。通用标定包含用于计算来自fp的参数的算法。这些算法是以s::can在测量许多可比较并且具有代表性的测量介质的经验为基础的。如有特殊要求或者对准确度要求很高,则有必要进行本地标定.

矩阵(matrix):在不同物质中测量介质的组成。

测量路径:光线通过测量介质的路径。单位:mm。吸收随着测量路径的长度成线性增长。测量路径越短,测量围越大;测路径越长,测量精度越高。探头可提供下面几种测量路径:1mm,2mm,5mm(废水,河水),35mm(河水,饮用水)。

测量窗口:光线通过测量窗口进入介质从另外一个离开。可以利用功能性检查来判断测量窗口是否堵塞。

Multi::lysertm:可以测量硝酸盐(no3-neq),有机碳(CODeq,TOCeq等)以及浊度(FTUeq,TSSeq等)的s::can滤波频谱仪传感器探头。

Nitro::lysertm:可以测量硝酸盐(no3-neq),有机碳(CODeq,TOCeq等)的s::can滤波频谱仪传感器探头。

参数:从fp获得的浓度。可以使用通用标定计算出来,而且可以根据使用本地

标定所做出的实验结果进行调整。

参考测量:作为每个测量的基础的所有波长的零点。(“零光谱”)。请不要与标定混淆!在功能性检查时,参考测量使用蒸馏水来进行。

SAC:对于某个波长的特殊测量系数(德语SAK)。在德国,SAC254已经替代了依照ATV M269/1999的CSB.

采样:测量介质中的一部分。在本地标定时,用于与实验室结果进行对比。

设置:测量过程所要求的参数设置,例如:测量周期,清洗周期等。Spectro::lyser tm:可以测量高度8个参数的s::can滤波频谱仪传感器探头。S::canpoint:用于标明特殊的测量位置和相关设置。每个名字最长可为8个字母。(例如:DANUBE)

4.测量

4.1光谱测量原理

滤波频谱传感器探头是根据UV-VIS光谱测定法的测量原理来进行工作的。通过光线经过介质产生的衰减来测量介质中的物质。光线通过介质后,通过一个特殊的探测器来测量它的强度。每个溶解物质的分子都吸收具有特定波长的光的辐射。物质的浓度确定了读数的大小:特定物质的浓度越大,它消弱光的能力越强。

吸收或衰减代表了光线通过介质(一般为蒸馏水)前后的比率。随着浓度的增加吸收成线性增长。

4.2 功能检查/参考测量

硬件(双光线测量、自动清洗装置)和软件(特殊浓度补偿)的特性可以保证s::can滤波频谱仪传感器探头高度稳定。即使长时间工作,读数也不会发生漂移。在特殊环境(例如高机械应力或者温度变化频繁),需要大量连续数据或者对数据精度要求很高的环境工作时,建议每六个月或一年进行一次功能检查。

测量窗口如果堵塞会影响测量精度。因此如果应用在废水中,我们建议使用气水清洗装置;该装置通过变送器可以连接到可用的压缩空气管道或压缩机、水泵等装置。

使用软件[8.5.3]和多功能滑块[9.1]可以不在测量现场进行功能检查。进行功能检查的步骤如下:

定期检查(例如:每6个月)

水质在线监测仪站房建设要求与水质在线监测仪表技术要求(1)

水质在线监测仪站房建设要求及水质在线监测仪表技术要求

一、水质在线监测房规范建设要求及总排口建设要求 (5) 1、基本要求 (5) 2、站房建设规范 (5) 3、站房内供电要求 (8) 4、站房室内环境要求 (9) 5、监测房配套设备 (9) 6、监测站房配管、配线、铭牌标示 (10) 二、排放口规范要求 (11) 三、水质采样单元 (13) 四、保温与防冻 (15) 五、水质在线监测仪表技术要求 (16) (1)水质CODcr在线监测仪技术要求 (16) 1、基本功能要求 (16) 2.主要技术指标及技术参数 (17) (2)、氨氮在线监测仪技术要求 (18) 1、基本功能要求 (18) 2.主要技术指标及技术参数 (19) (3)、总磷在线监测仪技术要求 (20) 1、基本功能要求 (20) 2.主要技术指标及技术参数 (21)

(4)、PH在线监测仪技术要求 (22) 1.基本功能要求 (22) 2.主要技术指标及技术参数 (22) (5)、明渠流量计线监测仪技术要求 (23) 1.基本功能要求 (23) (6)、数据采集传输仪技术要求 (25) 1.基本功能要求 (25) 附件一、水质仪器检测数据通讯协议说明 (27) 附件二、前端监测设备与数据采集仪反控指令说明 (30)

前言 为了贯彻落实《国家重点监控企业污染源自动监测数据有效性审核办法》和《国家重点监控企业污染源自动监测设备监督考核规程》(环发〔2009〕88号)等有关规定,规范国家重点监控企业污染源自动监测设备监督考核合格管理办法。为了给水质分析仪提供一个合适的工作环境,按照水污染在线监测系统安装技术规范(试行)-HJ/T353-2007的要求,需要企业专门设置水质在线监测站房及配套设备。

逻辑分析仪使用手册.pdf

目录 概述 (1) 第1章逻辑分析仪原理及基本概念 (2) 1.1逻辑分析仪原理 (2) 1.2逻辑分析仪基本概念 (2) 1.2.1定时采样 (2) 1.2.2状态采样 (3) 1.2.3动态采样 (3) 1.2.4存储容量 (3) 1.2.5采样时间 (4) 1.2.6测量带宽 (4) 1.2.7门限电压 (5) 1.2.8触发 (5) 1.2.9触发位置优先 (5) 1.2.10触发状态优先 (5) 第2章致远逻辑分析仪 (6) 2.1命名规则 (6) 2.1.1LA系列逻辑分析仪 (6) 2.1.2LAB系列逻辑分析仪 (6) 2.2功能特色 (7) 2.2.1测量线 (7) 2.2.2逻辑笔 (7) 2.2.3频率计 (8) 2.2.4双边沿同步采样 (9) 2.2.5触发方式 (9) 2.2.6数据滤波 (10) 2.2.7数据导出 (11) 2.2.8协议分析 (11) 2.3型号对比 (11) 2.3.1LA系列对比 (11) 2.3.2LAB系列对比 (12) 2.3.3LA系列与LAB系列对比 (13) 第3章如何使用逻辑分析仪 (14) 3.1逻辑分析仪软件安装 (14) 3.1.1安装ZlgLogic软件 (14) 3.1.2安装驱动程序 (18) 3.1.3软件升级 (19) 3.2逻辑分析仪硬件连接 (21) 3.3逻辑分析仪使用步骤 (25) 3.3.1频率测量 (25) 3.3.2总线测量 (28) 3.3.3SPI测量 (31) 3.3.4SPI总线分析 (32) i

3.3.5SPI触发设置 (34) 3.4逻辑分析仪使用注意事项 (36) 3.4.1确保接地良好 (36) 3.4.2合理设置采样频率 (37) 3.4.3合理设置触发方式 (37) 3.4.4合理设置门限电压 (37) 3.4.5使用Timing-State模式 (38) 3.4.6差分信号测量 (38) 第4章逻辑分析仪的应用 (39) 4.1逻辑分析仪队列触发的应用 (39) 4.1.1队列触发在数字通信系统的应用 (39) 4.1.2队列触发在工业自动化领域的应用 (40) 4.2逻辑分析仪数据延迟触发的应用 (42) 4.2.1原理分析 (42) 4.2.2测试步骤 (42) 4.3逻辑分析仪插件触发的应用 (44) 4.4逻辑分析仪外部触发的应用 (44) 4.4.1触发输出在电路调试中的应用 (44) 4.4.2触发输入在电路调试中的应用 (46) 4.4.3其它应用 (47) 4.5逻辑分析仪在数据采集开发系统中的应用 (47) 4.6逻辑分析仪在1-wire总线开发中的应用 (49) 4.7逻辑分析在LIN总线开发中的应用 (51) 4.8逻辑分析仪在DALI总线开发中的应用 (53) 4.9逻辑分析仪在CAN总线开发中的应用 (54) 4.10逻辑分析仪在FPGA开发中的应用 (55) 4.11逻辑分析仪在ACTEL平台中的应用 (57) 4.11.1方案介绍 (58) 4.11.2实现过程 (58) 4.12逻辑分析仪在RFID开发中的应用 (60) 4.12.1方案介绍 (60) 4.12.2方案实现 (60) 4.12.3实现过程 (61) 4.13逻辑分析仪在SDRAM开发中的应用 (62) 4.13.1硬件平台介绍 (62) 4.13.2建立应用平台 (63) 4.13.3逻辑分析仪测量应用 (64) 4.14逻辑分析仪在USB开发中的应用 (65) 4.14.1测量方法 (66) 4.14.2应用实例 (67) 4.15逻辑分析仪在CF卡开发中的应用 (68) 4.15.1CF卡原理 (68) 4.15.2插件解码分析 (69) 4.16逻辑分析仪在SD卡开发中的应用 (71) ii

雷磁DZS-707型多参数水质分析仪使用说明书

DZS-707型多参数水质分析仪使用说明书 上海仪电科学仪器股份有限公司

DZS-707型多参数水质分析仪使用说明书 目录 一、概述 1 二、仪器主要技术性能 1 三、仪器结构 2 四、仪器的使用 3 五、pH/ORP测量8 六、电导率测量11 七、溶解氧测量15 八、温度测量17 九、测量数据处理17 20 十、仪器的成套性

DZS-707型多参数设置分析仪软件使用说明书敬告用户: ●请在使用本仪器前,详细阅读本说明书并妥善保存。 ●仪器超过一年必须送计量部门或有资格的单位复检,合格后方可使用。 一、概述 DZS-707 型水质多参数分析仪是多参数电化学分析仪器,包含了pH/mV计、电导率仪和溶解氧分析仪的分析测试功能,可同时对一个样品进行温度、pH、电导率和溶解氧的测试。主要适用于农业、制造业、教育、科研、环保及综合服务行业,在工艺流程、质量控制或科学研究中,进行水溶液的多参数分析。 本仪器具有以下特点: 1、仪器可同时对一个样品进行温度、pH(电极电位)、电导率仪(TDS、盐度)和溶解氧(氧饱和度)的测试。 2、仪器采用计算机虚拟操作结构方式,模块化的电子单元转换器仅将各传感器的信号进行转换后传输到计算机进行处理。计算机软件承担了仪器的所有操作和分析功能,仪器体积小,成本低。 3、在Windows系统平台开发的仪器操作软件具备了数据处理功能,可以手动或自动记录测量数据并以曲线图和表格的形式显示记录的数据,以Access数据库格式进行保存,也可将数据转换到Word文档的表格或Excel电子表格。 4、软件具有曲线图复制功能,将曲线图复制到剪贴板中,供其他软件粘贴使用。 5、仪器的转换器可通过RS-232接口连接计算机,也可通过网络接口连接,使计算机通过网络远程操作仪器。 6、软件支持系统连接,通过网络接口连接系统服务器,将样品编号、测试人员、检测数据、测试日期和测试时间等分析测试信息传送到系统服务器进行测试数据综合处理。 二、仪器主要技术性能 2.1 pH/mV 1、测量范围 a) pH: (0~14.00)pH b) ORP: (0~±1999)mV 2、电子单元基本误差 a) pH: ±0.01pH±1个字 b) ORP: ±1mV±1个字 3、仪器的基本误差 a) pH: ±0.02pH±1个字 b) ORP: ±10mV±1个字 4、电子单元输入电流:不大于2×10-12A 5、电子单元输入阻抗:不小于1×1012Ω 2.2 电导率/TDS/盐度 1、测量范围 a) 电导率:0.000μS/cm~1.999μS/cm 2.00μS/cm~19.99μS/cm 20.0μS/cm~199.9μS/cm 200μS/cm~1999μS/cm 2.00mS/cm~19.99mS/cm 20.0mS/cm~199.9mS/cm(用常数为10的电极时) b) 盐度:(0.0~80.0)ppt c) TDS:(0~19900)mg/L 2、电子单元基本误差 a) 电导率: ±1.0%(F.S)±1个字

水质分析仪的工作原理及特点

水质分析仪的工作原理及特点 一、前言 随着近年来我国经济的快速发展,城市的工业和生活垃圾大量增加,目前对垃圾进行处理的主要方法是卫生填埋,而进行填埋都是露天作业,垃圾经压实后,随着垃圾中生物的分解及遇到雨雪天气时,雨水和雪水渗入填埋区,会产生垃圾渗滤液。渗滤液属高浓度有机废水,浓度值变化范围大,其中含碳氢化合物、硝酸盐、硫酸盐及微量铜、镉、铅等重金属离子,细菌指标很高,如不进行处理直接排入水体,将严重污染当地的水环境。为了保护水环境,必须加强对污水排放的监测。检测点的设计和检测仪表(主要是水质分析仪)的质量对水环境监测起着至关重要的作用,本文结合某一污水处理厂的设计谈谈这方面体会。 二、水质分析仪的工作原理 污水处理厂使用的分析仪有两种:pH计和溶氧分析仪。 1、pH计的工作原理 水的pH值随着所溶解的物质的多少而定,因此pH值能灵敏地指示出水质的变化情况。pH值的变化对生物的繁殖和生存有很大影响,同时还严重影响活性污泥生化作用,即影响处理效果,污水的pH值一般控制在6.5~7之间。水在化学上是中性的,某些水分子自发地按照下式分解:H2O=H++OH-,即分解成氢离子和氢氧根离子。在中性溶液中,氢离子H+和氢氧根离子OH-的浓度都是10-7mol/l,pH值是氢离子浓度以10为底的对数的负数:pH=-log,因此中性溶液的pH值等于7。如果有过量的氢离子,则pH值小于7,溶液呈酸性;反之,氢氧根离子过量,则溶液呈碱性。 pH值通常用电位法测量,通常用一个恒定电位的参比电极和测量电极组成一个原电池,原电池电动势的大小取决于氢离子的浓度,也取决于溶液的酸碱度。该厂采用了CPS11型pH传感器和CPM151型pH 变送器。具体结构如图1所示,测量电极上有特殊的对pH反应灵敏的玻璃探头,

ZVB网络分析仪的使用操作手册

文件编号: 文件版本: A ZVB矢量网络分析仪操作指导书 V 1.0 拟制 _____________ 日期_______________ 审核 _____________ 日期_______________ 会审 _____________ 日期_______________ 批准 _____________ 日期______________ 生效日期:2006.10

操作规范: 使用者要爱护仪器,确保文明使用。 1、开机前确保稳压电源及仪器地线的正确连接。 2、使用中要求必须佩戴防静电手镯。 3、使用中不得接触仪器接头内芯(含连接电缆) 4、使用时不允许工作台有较大振动。 5、使用中不能随意切断电源,造成不正常关机。不能频繁开关机。 6、使用射频电缆时不要用力大,确保电缆保持较大的弧度。用毕电缆接头上加接头盖。 7、旋接接头时,要旋接头的螺套,尽量确保内芯不旋转。 8、尽量协调、少用校准件。校准件用毕必须加盖放回器件盒。 9、转接件用毕应加盖后放回盒中。 10、停用时必须关机,关闭稳压电源。方可打扫卫生。 11、无源器件调试必须佩戴干净的手套。 ______________________________________________________________________________

概述:1、本说明书主要为无源器件调试而做,涵盖了无源器件调试所需的矢量网络分析仪基本能,关于矢量网络分析仪的其它更进一步的使用,请参照仪器所附的使用说明书。 2、本说明书仅以ZVB4矢量网络分析仪为例,对其它型号矢量网络分析仪,操作步骤基本相 同,只是按键和菜单稍有差别。 3、仪器使用的一般要求仪器操作使用规范。 4、方框内带单引号的键为软菜单(soft menu), 5、本仪器几乎所有操作都可以通过鼠标进行。

mms33(GE微量水分析仪说明书)

GE Industrial Sensing Moisture Monitor Series 3 Hygrometer Abridged Manual

GE Industrial Sensing Moisture Monitor Series 3 Hygrometer Abridged Manual 914-110A4 August 2004 Moisture Monitor Series 3 Hygrometer is a GE Panametrics product. GE Panametrics has joined other GE high-technology sensing businesses under a new name—GE Industrial, Sensing.

Warranty Each instrument manufactured by GE Infrastructure Sensing, Inc. is warranted to be free from defects in material and workmanship. Liability under this warranty is limited to restoring the instrument to normal operation or replacing the instrument, at the sole discretion of GE Infrastructure Sensing, Inc. Fuses and batteries are specifically excluded from any liability. This warranty is effective from the date of delivery to the original purchaser. If GE Infrastructure Sensing, Inc. determines that the equipment was defective, the warranty period is: ?one year for general electronic failures of the instrument ?one year for mechanical failures of the sensor If GE Infrastructure Sensing, Inc. determines that the equipment was damaged by misuse, improper installation, the use of unauthorized replacement parts, or operating conditions outside the guidelines specified by GE Infrastructure Sensing, Inc., the repairs are not covered under this warranty. The warranties set forth herein are exclusive and are in lieu of all other warranties whether statutory, express or implied (including warranties of merchantability and fitness for a particular purpose, and warranties arising from course of dealing or usage or trade). Return Policy If a GE Infrastructure Sensing, Inc. instrument malfunctions within the warranty period, the following procedure must be completed: 1.Notify GE Infrastructure Sensing, Inc., giving full details of the problem, and provide the model number and serial number of the instrument. If the nature of the problem indicates the need for factory service, GE Infrastructure Sensing, Inc. will issue a RETURN AUTHORIZATION number (RA), and shipping instructions for the return of the instrument to a service center will be provided. 2.If GE Infrastructure Sensing, Inc. instructs you to send your instrument to a service center, it must be shipped prepaid to the authorized repair station indicated in the shipping instructions. 3.Upon receipt, GE Infrastructure Sensing, Inc. will evaluate the instrument to determine the cause of the malfunction. Then, one of the following courses of action will then be taken: ?If the damage is covered under the terms of the warranty, the instrument will be repaired at no cost to the owner and returned. ?If GE Infrastructure Sensing, Inc. determines that the damage is not covered under the terms of the warranty, or if the warranty has expired, an estimate for the cost of the repairs at standard rates will be provided. Upon receipt of the owner’s approval to proceed, the instrument will be repaired and returned.

CODcr水质在线自动监测仪

CODcr水质在线自动监测仪 检验原理HJ828-2017重铬酸盐法比色波长610nm 测量范围0-200/500/2000mg/L(可扩展)模拟输出4-20mA输出,负载电阻最大750Ω 检验依据HJ/T377-2007(环境部最新标准)数字输出RS232/RS485 20%±10%开关输出继电器输出 示值误差50%±8%其他输出微型打印机输出(选配) 80%±5%数据存储可以保存三年以上测量数据,数据可循环存储重复性≦5%数据导出USB导出 低浓度漂移±5mg/L电源AC220±10%V,50±10%Hz,1.5A 高浓度漂移±5% 氨氮水质在线自动监测仪 检验原理HJ536-2009水杨酸分光光度法比色波长700nm 测量范围0-2/10/20/150/500mg/L(可扩展)模拟输出4-20mA输出,负载电阻最大750Ω 检验依据HJ/T101-2003(环境部最新标准)数字输出RS232/RS485 20%±8.0%开关输出继电器输出 示值误差50%±5.0%其他输出微型打印机输出(选配) 80%±3.0%数据存储可以保存三年以上测量数据,数据可循环存储重复性≦2.0%数据导出USB导出 低浓度漂移≦0.02%电源AC220±10%V,50±10%Hz,1.5A 高浓度漂移≦1.0% 总磷水质在线自动监测仪 检验原理GB/T11893-89钼酸铵分光光度法模拟输出4-20mA输出,负载电阻最大750Ω 比色波长660nm数字输出RS232/RS485 测量范围0-2/10/20/200mg/L(可扩展)开关输出继电器输出 检验依据HJ/T103-2003其他输出微型打印机输出(选配) 准确度±10%数据存储可以保存三年以上测量数据,数据可循环存储重复性误差±10%数据导出USB导出 零点漂移±5%电源AC220±10%V,50±10%Hz,1.5A 量程漂移±10%

水中色度在线分析仪

系统概述: COL-8000水中色度在线分析仪是由嵌入式系统控制的全自动在线水质色度在线监测仪,可适用于多种水质中色度的实时在线监测。样品经膜过滤后,被泵入测量池里,通过水样对光的感应变化计算出水样的色度值,对于污水或水质色度较大的水样,可自动进行成倍稀释,通过倍数稀释法可大大的扩展水质色度的测量范围。该仪器可广泛的应用于污水、地表水、饮用水等水质的在线自动色度测量。 系统特点: 1.水样预处理装置采用免维护设计,可确保预处理装置维护周期超过半年时间。 2.测定过程及结果满足国家标准和相关行业标准。 3.全进口器件及创新的分析流路设计和试剂配方保证了极高的测量重现性,目前测量重现性可达到3%。 4.全自动运行,无需人员值守,可实现自动调零、自动校准、自动测量、自动清洗、自动维护、自我保护、自动恢复等智能化功能。 5.在线监测方式多样化,可实现人工随时测量、自动定时测量、自动周期性测量等测定方式。 6.可配置超标报警装置,超标后仪器自动报警,提示用户进行工艺调整。 7.水中色度在线分析仪操作和维护及其简单。 8.电气部分和流体部分隔离,采用嵌入式控制系统,全自动运行。 技术参数: 测量原理:铂钴比色法或倍数稀释法; 量程:0~50或任意倍数; 测量类型:自动测量; 测量间隔:可任意设定; 测量时间:约5分钟; 测量精度:5%; 低检出限:0.1或1倍; 重现性:3%; 信号输出:标准4—20mA模拟输出,大负载400欧姆或0—5V,其它RS485或RS232可选;信号输入:1路分析,1路校正; 样品输送:自动取样,或水样自动输送; 水样要求:无结冰且无沉淀; 环境温度:0—40℃; 防护等级:IP55; 供电电源:220VAC,50Hz; 主机重量:35kg; 主机尺寸:500 mm x 780 mm x 320 mm; 预处理重量:30kg; 预处理尺寸:500 mm x 780 mm x 320 mm。

多功能水质监测仪的主要技术参数

多功能水质监测仪的主要技术参数 多功能水质监测仪(COD、总氮、总磷、氨氮、浊度)是独立开发的新一代水质监测仪。该仪器采用汉字菜单方式,按键少、操作简单直观,未经培训的人员也可迅速掌握仪器的使用方法。采用特制的密封专用比色管,达到方便快速测定水质的目的。中采用冷光源和窄带干涉滤光技术,专门设计的温度补偿电路实现了准确、高稳定的测定。多功能水质监测仪采用紧凑的一体化结构,集消解和测量于一体。仪器内部配备大容量闪存,用于保存30条校准曲线和1000个测量结果,在断电的情况下可将数据保存数十年而不丢失。输出接口可实时打印测量数据,也可在测量完成后打印输出。内置微功耗时钟可实时纪录校准及测量时间,而单片机数字处理技术保证了仪器的高自动化和高准确性。使之成为新一代智能多功能仪器。 多功能水质监测仪具有自动调零、浓度直读、线性回归、曲线存储、功能扩展、自动打印、数据输出等多种功能,能满足各种地表水、地下水、工业和生活污水、养殖及再生水的测量需要。可广泛地应用于环境保护、科研监测、生产控制等领域,是现代环境监测与管理理想的专用仪器之一。 多功能水质监测仪主要技术指标 测量精度±5%(全部) 重复性±3%(全部) 工作温度5~35℃ 相对湿度≤80% 最大功耗100W 重量4.5Kg 外形尺寸320×330×180(mm) 多功能水质监测仪注:基础型包括COD、氨氮、总磷,其他指标可自选。试剂整套价格分项报价: 0-2500mg/L(COD)800元/200次 0.0-5.0mg/L (总磷)325元/100次 0.00-5.00 mg/L(余氯)240元/100次 0.5-25/5-150mg/L(总氮)1820元/50次 1.0-1000NTU(浊度)无需试剂 0.00-8.00 mg/L 溴340元/100次 0-500PCU 色度无需试剂 0-400mg/L 钙硬度520元/100次(总硬度) 0-150mg/L 镁硬度 标准配置 主机1台 试剂各参数一套

(完整word版)Cobasc501分析仪用户操作手册

第一章系统概述 罗氏Cobas 6000是全自动免疫测定与光度测定分析系统,可定性或定量测定检测项目,Cobas 6000包括两部分: cobas c 501生化分析模块:进行分光光度测定和离子选择电极测定cobas e 601免疫分析模块:进行电化学发光测定 下面从控制单元、核心单元、cobas c 501生化分析模块等三部分介绍该系统(cobas e 601免疫分析模块不作介绍)。 1、控制单元 A 显示器(连接cobas ) D 触摸式显示器(主机) B 键盘/鼠标(连接cobas) E 键盘/鼠标(主机) C 计算机(连接cobas) F 计算机(主机) G 人体学PC支架

2、核心单元 1)核心单元轨道 A 核心单元 E 模块轨道 B 急诊标本位 F 常规标本上机位 C 条形码阅读器G 标本退出位 D 标本架转盘

急诊标本位 A 标本架托盘 B 标本架 C 标本杯、微量杯

2)标本架及标本容器 标本架不同类型、颜色和相应编号如下: 标本架类型标本架颜色标本架ID号软件中显示标本架上标签 常规标本架灰色5001-8999 001-3999 001-3999 STA T标本架红色4001-4999 E001-E999 S001-S999 定标标本架黑色2001-2999 S001-S999 C001-C999 QC标本架白色3001-3999 C001-C999 Q001-Q999 保养标本架绿色B999 B999 W999 标本容器有三种类型:标本试管、标本杯、定标及质控小瓶 标本试管直径为13mm或16mm,长度为75mm或100mm;标本杯可插入16 mm标本试管中用。 A 标本架上的标本杯 D 16mm×100mm试管 B 16mm×75mm试管 E 16mm×100mm试管上的标本杯 C 16mm×75mm试管上标本杯

多参数水质分析仪技术需求

多参数水质分析仪技术需求 . 设备名称:多参数水质分析仪 . 主要用途:用于生活饮用水、环境监测、疾控、质检、污水等领域各种复杂的水质分析。 . 工作条件:电源:±,;温度:~40 ;湿度:最大相对湿度(非冷凝). 技术指标: * 波长范围:~ * 波长准确度:± (~) 波长分辨率: 波长再现性:小于 * 扫描速度: (步增) 带宽: 波长校准模式:自动 * 波长选择: 自动:基于测试方法的自动选择波长; 自动:可根据试剂瓶上的条形码自动选择波长和测试方法; 手动:所有模式都可以使用,除了预存储程序; * 提醒机制:内置操作流程提示,并可提醒用户试剂的保质期,确保所使用的化学试剂是在保质期内 * 结果分析筛选:自动。消除由刮痕、裂纹或玻璃器皿污浊引起的参数无法读取问题

* 信息管理系统:与可以兼容 吸光度测量范围:± (波长~范围内) 吸光度测量准确度:(~);(~) 光度漂移:每小时± 光学系统:钨灯(可见光)和氘灯(紫外光),硅光电二极管检测器 杂散光:小于小于(采用碘化钾溶液于波长处测定) *接口:个接口,个以太网接口,可连接存储设备、键盘、打印机和条形码扫描仪;可连接以太网,进行实时数据传输,并可实现对在线仪器的远程校准。显示:英寸的彩色触摸屏显示 语言:多种语言选择,其中包括中文 显示模式:透光率(),吸光度和浓度 * 仪器自带内置测试方法程序大于种,用户可直接自动选择使用。 * 仪器自带分析质量保证功能。并带有趋势、比例等数据处理功能。 * 仪器带有不同光程比色皿的智能识别功能 * 消解器要求:加热速度:分钟内可从20℃加热至150℃;温度稳定性:±1℃; 消解温度:~165℃,任意选择;消解时间:~,任意选择,程序完毕后可自动停止加热;已预储存、等种常用消解程序。 . 主要配置: * 水质分析方法:大于种测试方法,用户可自建大于种测试方法。 比色池及适配器:×适配器(矩形10mm,20mm,50mm,英寸)和圆形(英寸),英寸方形比色池各一。

CO 分析仪使用操作手册

SG100磨煤机CO监测系统 用户使用说明 北京华能横河科技有限公司

目录 1.技术参数 (2) 2.系统组成.............................................................. .3 3.设备布置图(含吹扫部分) (4) 4.外部接线图 (6) 5.使用说明 (6) 5.1系统简介. (6) 5.2暖机和操作 (7) 5.3工作时序状态 (7) 5.4系统报警指示 (7) 5.5红外线分析仪 (10) 5.5.1红外线分析仪及操作 (10) 5.5.2屏幕显示内容 (13) 5.5.3设置/选项屏幕 (13) 5.5.4设置和校验 (14) 5.5.5参数设置 (17) 5.5.6维护模式 (19) 5.5.7校验 (21) 6.系统组成部件 (23) 7.外观和尺寸 (23) 7.1机柜尺寸 (23) 7.2采样探头尺寸 (23) 8.安装示意图 (24) 9.安装事项 (25) 10.故障分析 (26) 10.1分析仪维护 (27) 10.2部件的更换 (28) 10.2.1采样探头和过滤器的更换 (30) 10.2.2二级过滤器的过滤器芯的更换 (29) 10.2.3碟式过滤器的更换 (29) 10.2.4气泵的膜片的更换 (30) 10.2.5如何更换电子冷凝器 (31) 11.随机附件 (31)

1、技术参数 测量原理:红外线(NDIR) 测量范围:0~500/1000ppm,0~500/2000ppm,双量程 模拟输出信号:CO 浓度瞬时值,一路4~20mA 输出,负载电阻不超过550 Ω: 继电器触点输出:共有5 路输出,无源触点输出,触点容量为2 5 0 V A C,8 A。分别是:CO峰值超上限报警, CO峰值超上上限报警, 高低量程识别信号 维护状态 故障报警 显示:LCD,带背光源。 过滤式采样探头:·非电加热(内置过滤器) ·过滤器材质:2 μm,金钢砂 ·探头芯材质:SUS316不锈钢,长度为1000mm ·保护管材质:SUS316 ·法兰规格:日标,JIS 5K-65-FF ·重量:约12 公斤 采样管: ·φ10/φ8 SS316(标准长度5m),伴热温度65℃ ·伴热管供电电压:220VAC ±10V。功耗:25W/ 米 功能:(1)在线CO 浓度显示 (2)手动/ 半自动/ 自动校验 ·自动校验周期设定范围: 1~99小时(以1小时为单位)或1~40天(以1天为单位) ·自动校验气体流通时间设定范围: 60~599秒(以1秒为单位) ·自动/ 手动校验错误报警触点输出:当校正值超出满刻度50% 时 ·自动校验和维护状态触点输出信号: (3)输出信号保持功能 自动校验和维护的过程中,输出电流信号保持不变 (4)报警 ·CO瞬时浓度上限200ppm报警(可自行设定) ·CO 瞬时浓度上上限250ppm 报警(可自行设定) (5)其他功能: ·对仪器维护时,输出信号保持 ·量程改变识别触点输出,低量程时触点闭合 ·分析仪故障触点输出 使用条件:样气温度:60~140℃ ·环境温度:-10~+50℃ ·环境湿度:<90%RH(不冷凝) ·供电电压:220VAC ±10%,50 ±0.5Hz ·功耗:max1000VA 外形尺寸(H ×W ×D ):750×570×500mm

DZS-707型多参数水质分析仪使用说明书(精)资料

DZS-707型多参数水质分析仪使用说明书上海精密科学仪器有限公司 目录 一、概述 1 二、仪器主要技术性能 1 三、仪器结构 2 四、仪器的使用 3 五、 pH/ORP测量 8 六、电导率测量 11 七、溶解氧测量 15 八、温度测量 17 九、测量数据处理 17 十、仪器的成套性 20

敬告用户: ●请在使用本仪器前,详细阅读本说明书并妥善保存。 ●仪器超过一年必须送计量部门或有资格的单位复检,合格后方可使用。 一、概述 DZS-707 型水质多参数分析仪是多参数电化学分析仪器,包含了 pH/mV计、电导率仪和溶解氧分析仪的分析测试功能,可同时对一个样品进行温度、 pH 、电导率和溶解氧的测试。主要适用于农业、制造业、教育、科研、环保及综合服务行业,在工艺流程、质量控制或科学研究中,进行水溶液的多参数分析。 本仪器具有以下特点: 1、仪器可同时对一个样品进行温度、 pH (电极电位、电导率仪(TDS 、盐度和溶解氧(氧饱和度的测试。 2、仪器采用计算机虚拟操作结构方式, 模块化的电子单元转换器仅将各传感器的信号进行转换后传输到计算机进行处理。计算机软件承担了仪器的所有操作和分析功能,仪器体积小,成本低。 3、在 Windows 系统平台开发的仪器操作软件具备了数据处理功能,可以手动或自动记录测量数据并以曲线图和表格的形式显示记录的数据,以 Access 数据库格式进行保存,也可将数据转换到 Word 文档的表格或Excel 电子表格。 4、软件具有曲线图复制功能,将曲线图复制到剪贴板中,供其他软件粘贴使用。 5、仪器的转换器可通过 RS -232接口连接计算机,也可通过网络接口连接,使计算机通过网络远程操作仪器。 6、软件支持系统连接,通过网络接口连接系统服务器,将样品编号、测试人员、检测数据、测试日期和测试时间等分析测试信息传送到系统服务器进行测试数据综合处理。

水质在线监测系统

水质在线监测系统,通过建立无人值守实时监控的水质自动监测站,可以及时获得连续在线的水质监测数据( 常规五参数、COD、氨氮、重金属、生物毒性等),利用现代信息技术进行数据采集并将有关水质数据传送至环保信息中心,实现环保信息中心对自动监测站的远程监控,有利于全面、科学、真实地反映各监测点的水质情况,及时、准确地掌握水质状况和动态变化趋势。水质在线监测系统由水质在线分析仪、采样系统、辅助参数监测系统等组成。 其中水质在线分析仪是基于紫外全光谱技术的连续在线式水中有机物浓度分析仪,在水质的在线监测方面与传统的COD化学法和现有的紫外单/双波长法相比均具有非常明显的技术优势,同时给用户的使用带来了明显的经济效益,具体表现如下: 与传统的COD化学法在线监测设备想比,在技术上具有结构简单、可靠性高、响应速度快(1秒钟一个数据)实时性高、不存在二次污染等特点,从经济效益上讲水质在线分析仪具有运行费用低、维护周期特别长(一般可达到半年之久)、维护量小等显著特点。 与现有的紫外单/双波长法(利用污水在254nm处的吸光度与污水中COD之间的线性关系测定COD浓度)相比具有测试准确度高、检测范围宽、维护周期特别长(一般可达到半年之久)、维护量小等显著特点。这是因为单波长法仅能对有机污染物组分较为单一的污水或者污水中所含有机污染物组分相对固定的污水进行COD的测定,而对于污染物组分复杂多变的样品由于吸光度与COD之间的相关性较差直接导致测试结果的误差增大。紫外全谱扫描技术则通过污水的紫外光谱数据与有机污染物浓度之间所建立的数学模型来预测水中有机污染物的浓度,由于模型本身的外推能力会使测试准确度随着用户的使用时间增长而愈来愈高。在检测范围上采用专利型在线稀释装置,可以满足在不更换或调整比色皿的

水质在线分析仪检测原理

. . 铬:在酸性溶液和一定的温度及压力下,试样中各种价态和形态的铬被过硫酸钾或高锰 酸钾氧化成六价铬。六价铬与二苯碳酰二肼(DPC)反应生成紫红色 Cr-苯基偶氮碳酰肼配合物,于波长 540nm 处进行分光光度测定。在一定浓度范围内符合 Lambert-Beer 定律,吸光度是和水样中 Cr(VI)的浓度成正比。 铅:在碱性条件下,水样中的的铅与显色剂生成橙黄色络合物,该颜色的变化与样液中的铅含量成正比,仪器在466nm波长处检测其吸光度,从而计算出样液中的铅浓度。 镉:在碱性条件下,水样中的的镉与显色剂生成橙黄色络合物,该颜色的变化与样液中的镉含量成正比,仪器在434nm波长处检测其吸光度,从而计算出样液中的镉浓度。 铜:在弱碱性条件下,水样中的铜和双环己酮草酰二腙反应生成蓝色化合物,于波长600nm处检测反应后混合液的吸光度,通过朗伯—比尔定律换算得出水样中铜的含量。加上相应的消解装置,可以测量总铜的浓度。 锌:在碱性溶液中,水样中的锌与锌试剂生成蓝色的络合物,其颜色深度与水样中锌的浓度成正比,在波长620nm处检测反应后溶液的吸光度从而换算出水样中锌的浓度。 砷:先用过硫酸钾在加热条件下还原水或废水中的砷,冷却后加入显色剂会形成蓝色化合物,分析仪检测此颜色变化,通过程序换算得到其浓度值。 镍:在氨溶液中碘存在下,镍与丁二酮肟作用形成酒红色可溶性络合物,于波长530nm 处进行分光光度检测,通过程序运算得出镍的浓度值。 汞:在乙醇存在条件下,汞离子与汞试剂反应生成橙红色螯和物,在558nm波长处有最大吸收,可以定量检测。 总氮:在60℃以上的水溶液中过硫酸钾按如下反应式分解,生成氢离子和氧。 K2S2O8+H2O == 2KHSO4+1/2O2 KHSO4 == K++HSO4- HSO4- == H++SO42- 加入氢氧化钠以中和氢离子,使过硫酸钾分解完全。 在120℃~124℃的碱性介质条件下,用过硫酸钾作氧化剂,不仅可将水样中的氨氮和亚硝酸盐氮氧化为硝酸盐,同时将水样中大部分有机氮化合物氧化为硝酸盐,之后加入硫酸肼将硝酸盐还原为亚硝酸盐的形式,后与盐酸萘乙二胺反应生成紫红色络合物,在540nm波长下进行检测。 氯化物:氯离子与硫酸氰贡反应,交换出硫酸氢根离子与三价铁离子反应生成红色硫氰酸铁络合物,于波长460nm处进行分光光度测定。

多参数水质在线分析仪

产品概述: 慕迪科技多参数水质在线分析仪是国内符合国家标和行业标准的新一代在线分析仪。一台仪器可同时测定水中化学需氧量(COD)和水中氨氮(NH3N)、总磷(TP)总氮(TN),且每种待测因子的在线测定方法均符合现行国家标准和行业要求,待测参数的种类和数量可任意组合,用户可根据实际需要订购任何类型的多参数水质在线分析仪,为用户节省了使用成本。用户可通过定制化选型将该产品变化成: COD在线分析仪、氨氮在线分析仪 总磷在线分析仪、总氮在线分析仪 高猛酸盐指数在线分析仪 COD氨氮二合一在线分析仪 氨氮总磷二合一在线分析仪 总磷总氮二合一在线分析仪 COD氨氮总磷三合一在线分析仪 各种数值参数的测量方法: COD测量方法有紫外法、铬法、锰法; 氨氮测量方法有纳氏法、水杨梅法、电极法; 总磷测量方法是钼酸铵比色法; 总氮测量方法是紫外线比色法; 产品特点: 同时在线自动测定多参数活单参数; 各种待测参数可任意组合和定制; 水质大型多参数可大大节省用户的使用成本; 标准溶液的灵活校正,保证了较高重复性; 反应时间的灵活设定保证了任何水样都能准确测量; 使用长寿命注射泵抽取试剂盒水样; 在线测量、自动周期性测量等测定方式; 先进的自我诊断、报警系统,可定制化报警; 输出接口多样化:4-20mA、RS232、RS485; 技术参数: 测试量程:COD(0-500)其他(0-50)mg/L; 准确度:<10%; 重复性:<5%; 测试方式:定时、等间隔、手动、连续测量; 校正方式:自动定时校正或手动校正; 预处理维护:仅需更换试剂; 自检系统:仪器状态自我诊断; 继电器控制:2路24V 1A 继电器高低控制; 数据传输方式:4-20mA、RS232、RS485; 显示:8.0寸彩色触摸屏,分辨率800*600; 数据存储:一年有效数据; 尺寸:500*1650*320mm;

在线水质分析仪说明书

目录 1.操作说明 (3) 2.G::SYSTEM简介 (4) 3 常用术语 (5) 4.测量 (6) 4.1光谱测量原理 (6) 4.2 功能检查/参考测量 (6) 4.3 探头的安装 (7) 5.安装 (8) 5.1产品清单 (8) 5.2 组装 (8) 5.3连接压缩空气清洗装置 (8) 5.4探头的安装 (9) 6 操作 (10) 6.1 con::lyte的启动 (10) 6.2 探头的搜索和初始化 (11) 7 测量显示/主要菜单 (12) 7.1 各按键的功能 (12) 7.2读数和信息显示 (12) 7.3 主菜单/菜单项 (13) 8 测量/CON::L YTE操作 (15) 8.1自动 (15) 8.2 手动操作 (15) 8.3 运行日志和数据 (16) 8.4 settings(测量参数设置) (16) 8.4.1 Settings \ s::canpoint (16) 8.4.2 Settings \ Measurement (16) 8.4.3 Settings \ Cleaning (17) 8.4.4 In-/Output(电源和中继界面) (17) 8.4.5 In-/Outputs \ mA Output (18) 8.4.6 In-/Outputs \ Relays (Fault Relay) (18) 8.4.7 In-/Outputs \ Reset settings (19) 8.5 Calibration (19) 8.5.1 Calibration \ Global calibration (19) 8.5.2 Calibration \ Local cal. (19) 8.5.3 Calibration \ function control (20) 8.6 Information (20) 8.7 Extra (20)

水质在线自动监测仪的功能特点及系统分析

水质在线自动监测仪的功能特点及系统分析 为了保护水环境,必须加强对污水排放的监测,水质在线自动监测仪是用来监测监测质量变化的专业仪器,该仪器可以监测水体溶解氧、浊度、pH值、电导率、水温等参数。在环境保护、水质的检测和水资源保护中起到了重要的作用。 托普云农水质在线自动监测仪是用来监测监测质量变化的专业仪器,也叫水质在线自动监测仪,水质监测仪可以监测水体溶解氧、浊度、pH值、电导率、水温等参数。在环境保护、水质的检测和水资源保护中起到了重要的作用。 水质在线自动监测仪/水质在线监测系统/水质在线分析仪功能特点: 采用高精度传感器。 低功耗设计,增加系统监控和保护措施,防止电源短路或外部干扰而损坏,避免系统死机。 带SD卡,可无限存储数据。 数据监测:采用高精度传感器可实时监测水体溶解氧、浊度、pH值、电导率、水温。 数据传输:水质在线监测技术可在极短的时间内,将监测点所采集的数据通过GPRS上传至用户端,确保数据的及时性和有效性。与传统人工取样监测相较,不仅简化了繁琐的程序,还节约了监测时间。 监测预警:通过系统云平台,用户可设置所监测参数的安全值域,一旦前端传感器监测到某处水质参数超过安全值域,系统将发送报警信息通知用户,以便及时处理,确保蓄水池、水库的水质良好。 数据分析:可设置监测时段,自动采集,无需人工看顾。系统自动生成数据图表,用户可直观了解水质变化情况。采集数据可保存,随时查看历史数据,并

可用于分析,为用户的水产养殖和农作物种植总结经验,指导管理。 上传设置:根据需要开关上传功能,并且上传到服务器。 管理云平台功能: 1、自带管理云平台,无论身在何处,可随时随地通过电脑网页在线查看历史数据和实时数据。也可以随时随地通过智能手机查看历史和实时数据。 2、数据可通过GPRS方式上传至管理云平台。平台内数据可下载,分析,打印。 3、用户可为设备配置传感器报警条件,预置若干常用报警。 4、平台支持设备数据存储,提供足够容量可永久保存。 5、平台为设备数据提供曲线与表格等报表形式,且数据可导出与导入。 其他气象仪器:温室小管家、手持农业气象监测仪、温湿光三参数记录仪、二氧化碳记录仪、土壤温度记录仪、光合有效辐射计、积温积光仪、农林小气候信息采集系统

相关文档
最新文档