双体均速管流量计的创新优化设计

一一收稿日期:2014-09-15作者简介:杨笑梅(1988),女,河北人,硕士,研究方向为流体

机械三

双体均速管流量计的创新优化设计

杨笑梅1,张亚军2,朱一莹1,沈新荣1

(1.浙江大学流体工程研究所,杭州310027;

2.西安陕鼓动力股份有限公司自动化中心,西安710075)

一一摘要:基于流动控制原理,将文丘里效应应用到均速管流量计中,建立了几种双体均速管模型三通过数值分析不同模型的流量系数及其引起的永久压损随速度的变化规律,并与威力巴原型进行比较,从中选取最优模型三

关键词:均速管流量计;流量系数;永久压力损失

中图分类号:TH814一一文献标志码:A一一文章编号:1000-0682(2015)03-0040-04

Innovation and optimized design of tow -profile averaging pitot tube

YANG Xiaomei 1,ZHANG Yajun 2,ZHU Ying 1,SHEN Xinrong 1

(1.Institute of Fluid Engineering Research ,Zhejiang University ,Hangzhou 310027,China ;

2.Automatic Technology Sector ,Xi an Shaangu Power Co ,Ltd.,Xi an 710075,China )

一一Abstract :In this paper,on the basis of the flow control theory,several tow -profile averaging pitot tube models by the Venturi effect applied to the averaging pitot tube were proposed.The variations of一the flow coefficient and the permanent pressure loss with flow verocity on different models were numerically analyzed and the best model was obtained compared to the original Veris bar.一一Keyword :averaging pitot tube;flow coefficient;permanent pressure loss

0一引言

均速管流量计属于差压式流量计,是基于早期皮托管测速原理发展起来的一种新型流量测量元件[1]三以威力巴流量计为典型代表的均速管流量计,以其结构简单二测量精度高二压力损失小二节能效果显著等优点,已被广泛应用于工业现场进行流量测量[2]三但传统的均速管流量计输出压差小二其测量结果易受被测流体扰动的影响[3]三同时,传统均速管流量计在被测流体流速较低时其流量系数不稳定,因而在测量低流速工况时其应用受到制约三

为了在保持永久压损低的前提下,提高均速管流量计的有效输出压差,从流动控制的角度出发,将均速管流量计与文丘里管[4]的特点相结合,创新设计了几种双体均速管流量计三通过CFD 数值模拟,对不同双体模型的流量系数及永久压力损失进行研究分析,从而确定出一种新型的二高精度二宽量程比

的双体均速管流量计三

1一均速管流量计的测量原理

均速管流量计的基本结构如图1所示,它主要由5个部分组成:检测杆二总压孔二静压孔二总压管二静压管三将均速管流量计检测杆插入管道中,当流体流过检测杆时,在其前部产生一个高压分布区即总压,在其两侧后部产生一个低压分布区,高二低压区的流体通过总压孔和静压孔进入到总压腔和静压腔,压力在腔体内平均之后,分别由总压管及静压管引出,总压与静压之差反映了流体平均速度,以此可以推算出流体的流量

图1一均速管流量计基本结构

04四工业仪表与自动化装置一一一一一一一一一一一一一一一一2015年第3期