柱的内力组合表

柱的内力组合表
柱的内力组合表

S Gk S Qk S GE

18.86 3.5520.635-5.644 5.644-37.97237.972N773.9148.15847.975-10.2910.29-72.2872.28V-8.2-1.5-8.95 6.38-6.3842.94-42.94M

12.3 2.313.45-18.618.6-125.2125.2N773.9148.15847.975-10.2910.29-72.872.8V-8.2-1.5-8.95 6.38-6.3842.94-42.94M

0.7 4.37 2.885-10.4610.46-70.63270.632N1365.9368.561550.18 1.81-1.8115.12-15.12V-0.27-1.9-1.227.9-7.953.24-53.24M

0.35 2.85 1.775-19.5419.54-131.9131.9N1365.9368.561550.18 1.81-1.8115.12-15.12V-0.27-1.9-1.227.9-7.953.24-53.24M

-21.929-1.5-22.679-10.4610.46-70.63270.632N1543.83931740.3-1.8 1.8-15.1215.12V9.530.59.787.9-7.953.24-53.24M

-14.3-0.75-14.675-19.5419.54-131.9131.9N1543.8

393

1740.3

-1.81

1.81

-15.12

15.12

右震5b

风载

水平地震作用

(2)重力荷载代表值

(3)

左风4a

右风4b

左震5a

柱下端

内力类型

恒载(1)杆件编号控制截面柱上端

柱下端

柱上端

柱下端

柱上端

竖向荷载

S wk

S Ehk

活载

V9.530.59.787.9-7.953.24-53.24M

-17.879-8.43-22.094-5.644 5.644-37.97237.972N778.9190.87874.33510.29-10.2985.52-85.52V8.03 3.679.865 6.38-6.3842.94-42.94M

-12.65-5.5-15.4-18.618.6-125.2125.2N778.9190.87874.33510.29-10.2985.52-85.52V

8.03

3.67

9.865

6.38

-6.38

42.94

-42.94

下端

柱上端

柱下端

2. 底层柱下端截面组合的弯矩设计值应乘以《建筑抗震设计规范》GB50011-2010第6.2.3条规定的增大

3. 11a(b)栏:采用经级差调整后的柱端弯矩(10栏内的值)对剪力进行级差调整。

4. 如果是角柱,尚需满足《建筑抗震设计规范》GB50011-2010第6.2.6条的规定。

注:1. 框架顶层梁柱节点及轴压比小于0.15的梁柱节点无需进行柱端弯矩设计值的级差调整。

框架柱内力组合表 单位:弯矩(KN·m)∕剪力、轴力(KN) 第

Ehk

Eh S γ

19.9915 6.719522.9860.86618.772 5.580.948

-37.13901-27.65709-37.6178-21.8146-37.99776-28.51584-75.8764

1247.21121229.9241136.13861107.32661210.54161193.25441160.378

19.79639.077922.1646 4.300620.13329.414867.66

-38.0915-6.8435-46.61 5.47-38.504-7.256-181.24

1247.21121229.9241136.13861107.32661210.54161193.25441160.378

19.79639.077922.1646 4.300620.13329.414867.66

值的级差调整。

11-2010第6.2.3条规定的增大系数。

差调整。

的规定。

力、轴力(KN) 第 页;共页

G S

Sγ=

12a左震12b 右震13a左震13b 右震

-41.2479.44-41.2479.44738.8848

889.2272

1127.4464

1144.7336

48.94100211-67.0726736848.94100211-67.07267368-152.4848186.056-152.4848186.056738.344

889.768

1127.4464

1144.7336

110.4710021-67.07267368110.4710021-67.07267368-112.9248105.104-112.9248105.1041503.8976

1472.448

2156.5844

2153.5436

73.02022737-72.1637052673.02022737-72.16370526-176.1136180.544-176.1136180.5441503.8976

1472.448

2156.5844

2153.5436

73.02022737-72.1637052673.02022737-72.16370526-122.0894.48-122.0894.481654.9632

1686.4128

2401.248

2404.272

80.51954526-64.2933221180.51954526-64.29332211-196.6432160.0144-196.6432160.01441654.9632

1686.4128

2401.2396

2404.2804

选取有地震作用组合的结果或内力级差调整后的结果

M:12a(b)=γRE *10a(b)

N:12a(b)=γRE *9a(b) V:12a(b)=

γRE *11a(b)

选取地震作用组合的轴力和经过级差调整后的弯矩、剪力结果进行承载力调

承载力抗震调整最终设计值

80.51954526-64.2933221180.51954526-64.29332211

-82.0838.64-82.0838.64 928.3024750.42081210.54161193.2544 68.35442526-47.6693557968.35442526-47.66935579 -188.4896150.0512-188.4896150.0512 928.3024750.42081210.54161193.2544 68.35442526-47.6693557968.35442526-47.66935579

相关文档