50Ω系统分贝、伏、瓦换算表D d B m V P o

+53 100.0 200W

++++++++++++++++++++++++++++++++++++++++++++++++++50 70.7 100W

49 64.0 80W

48 58.0 64W

47 50.0 50W

46 44.5 40W

45 40.0 32W

44 32.5 25W

43 32.0 20W

42 28.0 16W

41 26.2 12.5W

40 22.5 10W

39 20.0 8W

38 18.0 6.4W

37 16.0 5W

36 14.1 4W

35 12.5 3.2W

34 11.5 2.5W

33 10.0 2W

32 9.0 1.6W

31 8.0 1.25W

30 7.10 1.0W

29 6.40 800m W

28 5.80 640m W

27 5.00 500m W

26 4.45 400m W

25 4.00 320m W

24 3.55 250m W

23 3.20 200m W

22 2.80 160m W

21 2.52 125m W

20 2.25 100m W

19 2.00 80m W

18 1.80 64m W

17 1.60 50m W

16 1.41 40m W

15 1.25 32m W

14 1.15 25m W

13 1.00 20m W

12 .90 16m W

11 .80 12.5m W

10 .71 10m W

9 .64 8m W

8 .58 6.4m W

7 .500 5m W

6 .445 4m W

5 .400 3.2m W

4 .35

5 2.5m W

3 .320 2.0m W

2 .280 1.6m W

1 .25

2 1.25m W

D d B m V P o

0 .225 1.0m W

1

.200 .80m W

2 .180 .64m W

3 .160 .50m W

4 .141 .40m W

5 .125 .32m W

6 .115 .25m W

7 .100 .20m W

8 .090 .16m W

9 .080 .125m W

10 .071 .10m W

11 .064

12 .058

13 .050

14 .045

15 .040

16 .0355

D d B m m V

-μ

17 31.5

18 28.5

19 25.1

20 22.5 .1m W

21 20.0

22 17.9

23 15.9

24 14.1

25 12.8

26 11.5

27 10.0

28 8.9

29 8.0

30 7.1 .001m W

31 6.25

32 5.8

33 5.0

34 4.5

35 4.0

36 3.5

37 3.2

38 2.85

39 2.5

40 2.25 .1W

41 2.0

42 1.8

43 1.6

44 1.4

45 1.25

46 1.18

47 1.00

48 0.90

D d B m V P o D d B m V P o

μ

-μ

-μ

49 0.80

50 0.71 .01W

51 0.64

52 0.57

53 0.50

54 0.45

55 0.40

56 0.351

57 0.32

58 0.286

59 0.251

60 0.225 .001W

61 0.200

62 0.180

63 0.160

64 0.141

D d B m V

μ

65 128

66 115

67 100

68 90

69 80

70 71 .1n W

71 65

72 58

73 50

74 45

75 40

76 35

77 32

78 29

79 25

80 22.5 .01n W

81 20.0

82 18.0

83 16.0

84 11.1

85 12.9

86 11.5

87 10.0

88 9.0

89 8.0

90 7.1 .001n W

91 6.1

92 5.75

93 5.0

94 4.5

95 4.0

96 3.51

97 3.2

98 2.9

99 2.51

100 2.25 .1p W

101 2.0

102 1.8

103 1.6

104 1.41

105 1.27

106 1.18

D d B m n V

107 1000

108 900

109 800

110 710 .01p W

111 640

112 580

113 500

114 450

115 400

116 355

117 325

118 285

119 251

120 225 .001p W

121 200

122 180

123 160

124 141

125 128

126 117

127 100

128 90

129 80 .1fW

130 71

131 61

132 58

133 50

134 45

135 40

136 35

137 33

138 29

139 25

140 23 .01fW

声音与分贝

我们知道,声音是一种振动波。声音通过空气传播、被我们听到,本质上就是空气分子的振动传到了耳朵里,引发鼓膜的振动。所以,声音的大小,其实反映的是这种振动的强度。由于空气振动会引起大气压强的变化,所以确切地说,我们应该用压强变化的程度来描述一个声音的大小,这就是“声压”的概念,它的单位是Pa(帕斯卡)。比如:1米外步枪射击的声音大约是7000Pa;10米外开过的汽车大约是0.2Pa。 用声压来描述声音强度虽然准确,但却有很明显的问题:声压的变化范围非常大,不同声音的声压可能相差成百上千倍。比如上面两个例子:虽然步枪的声音确实比汽车声要大,但要说大出几万倍,这无论如何也与我们的日常感觉有出入。 因此,物理学上使用了“分贝”的概念。对于声音,“分贝”是这样定义的:我们将某一个声压值定义为“标准值”(0分贝),这是一个固定的值;任何一个声音,都和这个标准值相除,取结果的对数(以10为底),再乘以20,这样算出来的就是这个声音的分贝。写成公式就是: 其中:GdB为分贝;V0 为声压标准值;V1 为声压测量值。 对于上面的两个例子,步枪射击的声音换算过来就是171分贝,汽车开过的声音是80分贝,这样不仅方便计算,而且比较符合一般人的听觉感受。 这里涉及到了一个作为“标准值”的声音。当我们计算在气体介质中传播的声音时,采用的标准值是2×10^-5 Pa(20μPa),这是人耳在1000Hz这个频率下能听到的最小的声音,大致相当于3米外的一只蚊子在飞。这就是物理上对“0分贝”的定义。事实上,很多人听不到这样弱的声音。根据世界卫生组织的定义,如果一个人能听到的最小声音在25分贝以下,就属于正常听力。 另外,“分贝”并不仅仅用来描述声音强弱,它还被运用在电子学等其它物理领域,比如用来描述信号的增益衰减、信噪比等等。用来表示声音强弱时,“分贝”被写成dB(SPL),其中dB 是decibel(分贝)的缩写,SPL是Sound Pressure Level(声压位准)的缩写。除此以外,分贝还有别的形式。 通过上面对“分贝”的描述,我们会发现: 1. “分贝”并不反映声音的绝对响度,它是以某一个声音为基准,描述声音响度的相对关系。科学一点说,它把一个指数增长的物理量转换成了线性增长的物理量,便于计算。 2. “0分贝”并不代表“没有声音”,它只是一般认为人类能听到的最小声音而已。完全有可能有比0分贝还弱的声音(比如4米外的一只蚊子),那就是负分贝了。 3. 上面提到的2×10^-5 Pa,是用于计算“在空气或其它气体中传播的声音”时使用的标准值。当计算通过水下等液体介质传播的声音时,就要采用不同的标准值(1×10^-6 Pa,1μPa)。

交流毫伏表的使用

交流毫伏表的使用 实验室提供两种型号的交流毫伏表:一种是上海爱仪电子设备有限公司生产的AS2294D双通道交流毫伏表,测量电压范围:30μ V----300V,共分13档,测量电压频率范围:5Hz----2MHz,测量电平范围-70----50dB;另一种是苏州同创电子有限公司生产的TC2172A单通道交流毫伏表,测量电压范围:30μV----100V,共分12档,测量电压频率范围:5Hz----2MHz,测量电平范围-70----40dB。 一、开机前的准备工作及注意事项 1、测量仪器水平放置 2、指针调零:AS2294D有两条指针需要调零 3、测量量程置最大档,以防开机时打弯指针。AS2294D开机时会自动置于最高档不用设置。仪表暂时不用时应将量程置于较大档位,将输入端短路。 4、接通电源及输入量程转换时,由于电容放电,指针有所晃动,需等指针稳定后读数。 5、交流毫伏表只能用来测量正弦交流信号的有效值,若测量非正弦交流信号要经过换算。 二、使用方法 1、开机预热10秒以上 2、将探头上的红、黑鳄鱼夹断开后与被测电路并联,黑色鳄鱼夹始终接电路的公共地。 3、应使指针指在刻度盘中间偏右的部分再读数,如果指针基本不动或者动得很少,应逐级递减量程。 4、读数方法:刻度盘分为0----1和0----3两种刻度,凡逢一量程直接在0----1刻度线读取,逢三量程直接在0----3刻度线读取。 三、AS2292D的特殊使用 1、AS2292D是双通道交流毫伏表,左通道对应黑色指针,右通道对应桔色指针。SYNC是同步操作,ASYN是异步操作。 2、AS2292D由两个电压表组成,在异步工作时是两个独立的电压表,一般测量两个电压量程相差比较大的情况下,如测量放大器增益,可用异步工作状态。 3、同步工作时,可由一个通道量程控制旋钮同时控制两个通道的量程,特别适用于立体声或者二路相同放大特性的放大器情况下做测量。 4、AS2292D具有输出功能,可作为二独立的放大器用。

分贝计算

2007-黄杰(54584749) 22:46:57 就是因为现在基站不让随便建,所以要把发射功率提高,这样就能扩大覆盖范围2007-黄杰(54584749) 22:47:10 我们明年还要做300W呢 1.分贝的计算: dB=10*log(功率);记住一个3dB原则:每增加或降低3dB,意味着增加一倍或减少一半的功率。 +3dB:两倍大(乘以2);+10dB:10倍大(乘以10); -3dB:减小到1/2(除以以2);-10dB:减小到1/10(除以以10); 那这里有一个很简单的计算方法, 例如:增益为4000mw那换算dB是多少呢? 4000=10*10*10*2*2;那dB=10+10+10+3+3=36dB; 又例如:5000的增益是多少dB呢? 5000=10*10*10*10/2;那dB=10+10+10+10-3=37dB。 一般无委会或者FCC要求民用发射功率不能超过100mw也就是20dBm.所以WIFI 的AP发射功率不能超过这个数值。 类似的而50mw也就是17dBm了,而200mw就是23dBm. 2.百分比带宽:为带宽与中间频率的比值。 例如:75MHZ到125MHZ的百分比带宽为:[(125-75)/((125+75)/2)]*100%=50%; 当百分比带宽<50%叫窄带,>50%叫宽带; 3.VSWR:电压驻波比(VSWR)是射频技术中最常用的参数,用来衡量部件之间的匹配是否良好定义 VSWR (电压驻波比,有时也称作垂直驻波比),用来衡量无线信号通过功率源、传输线、最终进入负载(例如,功率放大器输出通过传输线,最终到达天线)的有效传输功率。 对于一个理想系统,传输能量为100%,需要源阻抗、传输线及其它连接器的特征阻抗、负载阻抗之间精确匹配。由于理想的传输过程不存在干扰,信号的交流电压在两端保持相同。

数字式交流毫伏表说明书

毕业设计说明书 数字式交流毫伏表电路 的设计 专业电气工程及其自动化 学生姓名姜晓天 班级BM电气082 学号0851402211 指导教师成开友 完成日期2012年5月22日

数字式交流毫伏表电路的设计 摘要:当今社会是数字化的社会,是数字集成电路广泛应用的社会。数字集成电路本身在不断地进行更新换代。它由早期的电子管、晶体管、小中规模集成电路,发展到超大规模集成电路(VLSIC)以及许多具有特定功能的专用集成电路。 本文设计的电路分为模拟和数字两个部分,具有量程自动转换功能。输入信号经过输入通道进入放大器部分,经过放大后,由AC/DC转换电路转换为与交流电压有效值相等的直流电压。该直流电压经过V/F转换电路输出相应的频率量,然后计数器部分在秒脉冲的控制下进行技术测量,最后显示出读数,从而完成电压的测量。 本文所设计的数字式交流毫伏表的显著特点是测量范围宽,可测范围在500V 以下,最大分辨率为0.01mV,且可以实现量程自动转换,操作简单,使用方便。电压表还具有在一定测量范围内自动选择量程的功能,从而可以快速,方便,准确地测量电压。 关键词:A/D转换;V/F转换;量程自动转换;计数器

Digital AC millivoltmeter circuit design Abstract:Today's society is the digital society , the society of a wide range of applications of digital integrated circuits . Digital integrated circuits constantly upgrading . By the early tubes, transistors , small - scale integrated circuits developed to ultra - LSI ( VLSIC ) as well as many ASIC has a specific function . In this paper, the design of the circuit is divided into analog and digital two parts , with a range automatic conversion . After the input channel , the input signal into the amplifier section, after amplification by AC / DC converter circuit to convert the DC voltage equal to the AC voltage rms . The output frequency of the DC voltage conversion circuit through the V / F , then the counter part of the second pulse control techniques to measure , and finally show the reading , thus completing the measurement of the voltage . Designed digital AC millivoltmeter notable feature is the wide measuring range can be measured in the range below 500V , the maximum resolution of 0.01mV , and can realize automatic range conversion , simple operation, easy to use . The voltmeter also has automatically selected range in a certain measuring range of functions , which can be fast , convenient and accurate measurement of voltage . Key Words: A / D converter ; V / F conversion ; automatic conversion range ; counter

分贝与响度和声强

声音三要素响度响度,又称声强或音量,它表示的是声音能量的强弱程度,主要取决于声波振幅的大小。声音的响度一般用声压(达因/平方厘米)或声强(瓦特/平方厘米)来计量,声压的单位为帕(Pa),它与基准声压比值的对数值称为声压级,单位是分贝(dB)。对于响度的心理感受,一般用单位宋(Sone)来度量,并定义lkHz、40dB的纯音的响度为1宋。响度的相对量称为响度级,它表示的是某响度与基准响度比值的对数值,单位为口方(phon),即当人耳感到某声音与1kHz单一频率的纯音同样响时,该声音声压级的分贝数即为其响度级。可见,无论在客观和主观上,这两个单位的概念是完全不同的,除1kHz纯音外,声压级的值一般不等于响度级的值,使用中要注意。响度是听觉的基础。正常人听觉的强度范围为0dB—140dB(也有人认为是-5dB— 130dB)。固然,超出人耳的可听频率范围(即频域)的声音,即使响度再大,人耳也听不出来(即响度为零)。但在人耳的可听频域内,若声音弱到或强到一定程度,人耳同样是听不到的。当声音减弱到人耳刚刚可以听见时,此时的声音强度称为“听阈”。一般以1kHz纯音为准进行测量,人耳刚能听到的声压为0dB(通常大于0.3dB即有感受)、声强为10-16W/cm2 时的响度级定为0口方。而当声音增强到使人耳感到疼痛时,这个阈值称为“痛阈”。仍以1kHz纯音为准来进行测量,使人耳感到疼痛时的声压级约达到140dB左右。实验表明,闻阈和痛阈是随声压、频率变化的。闻阈和痛阈随频率变化的等响度曲线(弗莱彻—芒森曲线)之间的区域就是人耳的听觉范围。通常认为,对于1kHz纯音,0dB—20dB为宁静声,30dB--40dB为微弱声,50dB—70dB为正常声,80dB—100dB为响音声,110dB— 130dB为极响声。而对于1kHz以外的可听声,在同一级等响度曲线上有无数个等效的声压—频率值,例如,200Hz的30dB的声音和1kHz的10dB 的声音在人耳听起来具有相同的响度,这就是所谓的“等响”。小于0dB闻阈和大于140dB 痛阈时为不可听声,即使是人耳最敏感频率范围的声音,人耳也觉察不到。人耳对不同频率的声音闻阈和痛阈不一样,灵敏度也不一样。人耳的痛阈受频率的影响不大,而闻阈随频率变化相当剧烈。人耳对3kHz—5kHz声音最敏感,幅度很小的声音信号都能被人耳听到,而在低频区(如小于800Hz)和高频区(如大于5kHz)人耳对声音的灵敏度要低得多。响度级较小时,高、低频声音灵敏度降低较明显,而低频段比高频段灵敏度降低更加剧烈,一般应特别重视加强低频音量。通常200Hz--3kHz语音声压级以60dB—70dB为宜,频率范围较宽的音乐声压以80dB—90dB最佳。音高音高也称音调,表示人耳对声音调子高低的主观感受。客观上音高大小主要取决于声波基频的高低,频率高则音调高,反之则低,单位用赫兹(Hz)表示。主观感觉的音高单位是“美”,通常定义响度为40方的1kHz纯音的音高为1000美。赫兹与“美”同样是表示音高的两个不同概念而又有联系的单位。人耳对响度的感觉有一个从闻阈到痛阈的范围。人耳对频率的感觉同样有一个从最低可听频率20Hz到最高可听频率别20kHz的范围。响度的测量是以1kHz纯音为基准,同样,音高的测量是以40dB声强的纯音为基准。实验证明,音高与频率之间的变化并非线性关系,除了频率之外,音高还与声音的响度及波形有关。音高的变化与两个频率相对变化的对数成正比。不管原来频率多少,只要两个40dB的纯音频率都增加1个倍频程(即1倍),人耳感受到的音高变化则相同。在音乐声学中,音高的连续变化称为滑音,1个倍频程相当于乐音提高了一个八度音阶。根据人耳对音高的实际感受,人的语音频率范围可放宽到80Hz --12kHz,乐音较宽,效果音则更宽。音色音色又称音品,由声音波形的谐波频谱和包络决定。声音波形的基频所产生的听得最清楚的音称为基音,各次谐波的微小振动所产生的声音称泛音。单一频率的音称为纯音,具有谐波的音称为复音。每个基音都有固有的频率和不同响度的泛音,借此可以区别其它具有相同响度和音调的声音。声音波形各次谐波的比例和随时间的衰减大小决定了各种声源的音色特征,其包络是每个周期波峰间的连线,包络的陡缓影响声音强度的瞬态特性。声音的音色色彩纷呈,变化万千,高保真(Hi— Fi)音响的目标就是要尽可能准确地传输、还原重建原始声场的一切特征,使人们其实地感受到诸如声源定位感、空间包围

dB换算表

■dB換算表

3dB法则总结: 对功率比dB=10log10(P2/P1)而言,每增加或减少3dB,表示P2比P1增 强或减弱2倍。 对电压比dB=20log10(V2/V1)而言,每增加或减少3dB,表示P2比P1增 强或减弱√2倍。 无线电单位换算表-dBmV、mW、dBuV、dBm、mVpp、mVp、mV(RMS)、uV(RMS)转换 型号:MSA338 厂商:迈克尼斯 无线电单位换算表-dBmV、mW、dBuV、dBm、mVpp、mVp、mV(RMS)、uV(RMS)相互转换 System:50W mVpp mVp mV(RMS)uV(RMS)dBmV dBuV mW dBm 2.00E-04 1.00E-047.07E-050.07-8 3.01-23.01 1.00E-13-130.00 5.00E-04 2.50E-04 1.77E-040.18-75.05-15.05 6.25E-13-122.04

1.00E-03 5.00E-04 3.54E-040.35-69.03-9.03 2.50E-12-116.02 1.00E-020.010.00 3.54E+00-49.0310.97 2.50E-10-96.02 1.00E-010.050.04 3.54E+01-29.0330.97 2.50E-08-76.02 1.00E+000.500.35 3.54E+02-9.0350.97 2.50E-06-56.02 10.00 5.00 3.54 3.54E+0310.9770.97 2.50E-04-36.02 20.0010.007.077.07E+0316.9976.99 1.00E-03-30.00 50.0025.0017.68 1.77E+0424.9584.95 6.25E-03-22.04 100.0050.0035.36 3.54E+0430.9790.97 2.50E-02-16.02 200.00100.0070.717.07E+0436.9996.990.10-10.00 300.00150.00106.07 1.06E+0540.51100.510.23-6.48 400.00200.00141.42 1.41E+0543.01103.010.40-3.98 500.00250.00176.78 1.77E+0544.95104.950.63-2.04 1000.00500.00353.55 3.54E+0550.97110.97 2.50 3.98 1100.00550.00388.91 3.89E+0551.80111.80 3.03 4.81 1200.00600.00424.26 4.24E+0552.55112.55 3.60 5.56 1300.00650.00459.62 4.60E+0553.25113.25 4.23 6.26 1400.00700.00494.97 4.95E+0553.89113.89 4.90 6.90 1500.00750.00530.33 5.30E+0554.49114.49 5.637.50 2000.001000.00707.117.07E+0556.99116.9910.0010.00 2500.001250.00883.888.84E+0558.93118.9315.6311.94 3000.001500.001060.66 1.06E+0660.51120.5122.5013.52 3500.001750.001237.44 1.24E+0661.85121.8530.6314.86 4000.002000.001414.21 1.41E+0663.01123.0140.0016.02 5000.002500.001767.77 1.77E+0664.95124.9562.5017.96 6000.003000.002121.32 2.12E+0666.53126.5390.0019.54 7000.003500.002474.87 2.47E+0667.87127.87122.5020.88 8000.004000.002828.43 2.83E+0669.03129.03160.0022.04 9000.004500.003181.98 3.18E+0670.05130.05202.5023.06 10000.005000.003535.53 3.54E+0670.97130.97250.0023.98 11000.005500.003889.09 3.89E+0671.80131.80302.5024.81 12000.006000.004242.64 4.24E+0672.55132.55360.0025.56 13000.006500.004596.19 4.60E+0673.25133.25422.5026.26 14000.007000.004949.75 4.95E+0673.89133.89490.0026.90 15000.007500.005303.30 5.30E+0674.49134.49562.5027.50 16000.008000.005656.85 5.66E+0675.05135.05640.0028.06 17000.008500.006010.41 6.01E+0675.58135.58722.5028.59 18000.009000.006363.96 6.36E+0676.07136.07810.0029.08 19000.009500.006717.51 6.72E+0676.54136.54902.5029.55 20000.0010000.007071.077.07E+0676.99136.991000.0030.00

dB换算表

对于无线工程师来说更常用分贝dBm这个单位,dBm单位表示相对于1毫瓦的分贝数,dBm和W之间的关系是:dBm=10*lg(mW)1w的功率,换算成dBm 就是10×lg1000=30dBm。2w是33dBm,4W是36dBm……大家发现了吗?瓦数增加一倍,dBm就增加3。为什么要用dBm做单位?原因大致有几个:1、对于无线信号的衰减来说,不是线性的,而是成对数关系衰减的。用分贝更能体现这种关系。2、用分贝做单位比用瓦做单位更容易描述,往往在发射机出来的功率几十上百瓦,到了接收端已经是以微微瓦来计算了。3、计算方便,衰减的计算公式用分贝来计算只用做加减法就可以了。 以1mW 为基准的dB算法,即0dBm=1mW,dBm=10*log(Power/1mW)。发射功率dBm-路径损失dB=接收信号强度dBm最小通信功率dBm-路径损失dB≥接收灵敏度下限dBm 最小通信功率dBm≥路径损失dB+接收灵敏度下限dBm 射频知识 ?功率/电平(dBm):放大器的输出能力,一般单位为w、mw、dBm。dBm是取1mw作基准值,以分贝表示的绝对功率电平。 ?换算公式: 电平(dBm)=10lgw 5W → 10lg5000= 37dBm 10W → 10lg10000 = 40dBm 20W → 10lg20000 = 43dBm ?从上不难看出,功率每增加一倍,电平值增加3dBm 1、dB dB是一个表征相对值的值,纯粹的比值,只表示两个量的相对大小关系,没有单位,当考虑甲的功率相比于乙功率大或小多少个dB时,按下面计算公式:10log(甲功率/乙功率),如果采用两者的电压比计算,要用20log (甲电压/乙电压)。 [例] 甲功率比乙功率大一倍,那么10lg(甲功率/乙功率)=10lg2=3dB。也就是说,甲的功率比乙的功率大3 dB。反之,如果甲的功率是乙的功率的一半,则甲的功率比乙的功率小3 dB。 2、dBi 和dBd

简易数字显示交流毫伏表(最终定稿)

简易数字显示交流毫伏表 摘要: 本系统由高级模拟器件、CPLD,可实现具有自动量程转换功能地真有效值测量、交流频率测量和标准幅度可控地正弦波输出等功能.测量部分具有高输入阻抗(R ≥2M,C<2.5pF),宽频带范围(10 HZ-5M HZ),宽电压范围(1mV-250V),高精度(有效值≤1%,频率<10-6)地优越性能.可满足多方位地需要. 关键词:静电计频率计高频放大真有效值 1.系统方案选择与论证 1.1设计要求 设计并制作一个简易数字显示地交流毫伏表,示意图如图-1所示. 图-1 简易数字显示交流毫伏表示意图 1.1.1基本要求 (1)电压测量 a、测量电压地频率范围100Hz~500KHz. b、测量电压范围100mV~100V(可分多档量程). c、要求被测电压数字显示. d、电压测量误差±5%±2个字.

e、输入阻抗≥1MΩ,输入电容≤50pF(本项可不做测试,在电路设计中给予保证) f、具有超量程自动闪烁功能. (2)设计并制作该仪表所需要地直流稳压电源. 1.1.2发挥部分 (1)将测量电压地频率范围扩展为10Hz~1MHz. (2)将测量电压地范围扩展到10mV~200V. (3)交流毫伏表具有自动量程转换功能. (5)其他. 1.2系统基本方案及框图 根据题目要求及适当地发挥,我们地硬件电路主要包括输入信号地有效值测量、输入信号地频率测量.其中前两者构成一个测量系统.测量系统包括:信号调理模块、A/D,D/A模块、信号真有效值转换模块、CPLD频率测试模块、算法控制器模块、键盘显示模块、语音播报及打印模块、电源模块等.图-3所示.为实现各模块地功能,分别作了几种不同地设计方案并进行了论证,我们选取了较好地方案实现. 图-3 测量系统框图

交流毫伏表使用说明

交流毫伏表使用说明 常用的单通道晶体管毫伏表,具有测量交流电压、电平测试、监视输出等 三大功能。交流测量范围是100mV?300V、5Hz?2MHz,共分 1 、3、 10、30、 100、300mV, 1 、3、 10、30、 100、300V共12档。现将其基本使用方法介绍如下: 1 、开机前的准备工作: (1)将通道输入端测试探头上的红、黑色鳄鱼夹短接; (2)将量程开关置于最高量程(300V)。 2、操作步骤: (1)接通220V电源,按下电源开关,电源指示灯亮,仪器立刻工作。为了保证仪器稳定性,需预热10秒钟后使用,开机后 1 0秒钟内指针无规则摆动属正常; (2)将输入测试探头上的红、黑鳄鱼夹断开后与被测电路并联(红鳄鱼夹接被测电路的正端,黑鳄鱼夹接地端),观察表头指针在刻度盘上所指的位置,若指针在起始点位置基本没动,说明被测电路中的电压甚小,且毫伏表量程选得过高,此时用递减法由高量程向低量程变换,直到表头指针指到满刻度的左右即可; (3)准确读数。表头刻度盘上共刻有四条刻度。第一条刻度和第二条刻度为测量交流电压有效值的专用刻度,第三条和第四条为测量分贝值的刻度。当 量程开关分别选1mV、10mV、100mV、IV、10V、100V档时,就从第一条刻度读

数;当量程开关分别选3mV、30mV、300mV、3V、30V、300V 时,应从第二条刻度读数(逢 1 就从第一条刻度读数,逢 3 从第二刻度读数)。例如: 将量程开关置“ 1V”,就从第一条刻度读数。若指针指的数字是在第一条刻度的0.7处,其实际测量值为0.7V;若量程开关置“3V”,就从第二条刻度读数。若指针指在第二条刻度的“2处,其实际测量值为2V。以上举例说明,当量程开关选在哪个档位,比如,1V档位,此时毫伏表可以测量外电路中电压的范围是0?1V,满刻度的最大值也就是IV。当用该仪表去测量外电路中的电平值时,就从第三、四条刻度读数,读数方法是,量程数加上指针指示值,等于实际测量值。 3 、注意事项: (1)仪器在通电之前,一定要将输入电缆的红黑鳄鱼夹相互短接。防止仪器在通电时因外界干扰信号通过输入电缆进入电路放大后,再进入表头将表针打弯。 (2)当不知被测电路中电压值大小时,必须首先将毫伏表的量程开关置最高量程,然后根据表针所指的范围,采用递减法合理选档。 (3)若要测量高电压,输入端黑色鳄鱼夹必须接在“地”端 (4)测量前应短路调零。打开电源开关,将测试线(也称开路电缆)的红黑夹子夹在一起,将量程旋钮旋到1mv 量程,指针应指在零位(有的毫伏表可通过面板上的调零电位器进行调零,凡面板无调零电位器的,内部设置的调零电位器已调好)。若指针不指在零位,应检查测试线是否断路或接触不良,应更换测试线。 (5)交流毫伏表灵敏度较高,打开电源后,在较低量程时由于干扰信号(感应信号)的作用,指针会发生偏转,称为自起现象。所以在不测试信号时应将量程旋钮旋到较高量程档,以防打弯指针。 (6)交流毫伏表接入被测电路时,其地端(黑夹子)应始终接在电路的地上(成为公共接地),以防干扰。 (7)交流毫伏表表盘刻度分为0—1和0—3两种刻度,量程旋钮切换量程分为逢一量程(1mv、10mv、0.1v ?…)?和逢三量程(3mv、30mv、0.3v ????)?, 凡逢一的量程直接在0—1 刻度线上读取数据,凡逢三的量程直接在0—3 刻度线上读取数据,单位为该量程的单位,无需换算。

分贝的基本概念

1、分贝 1.1 分贝的感觉 当物体振动时,在它周围就会产生声波,声波不断向外传播,被人们听到成为声音。人耳的听觉下限是0dB,低于15dB的环境是极为安静的环境,安静得会使人不知所措。乡村的夜晚大多是25-30dB,除了细心才能够体会到的流水、风、小动物等自然声音以外,其他感觉一片宁静,这也是生活在喧嚣之中的城市人所追求的净土。城市的夜晚会因区域不同而有所不同。较为安静区域的室内一般在30-35dB,住在繁华的闹市区或是交通干线附近的居民,将不得不忍受室内40-50dB(甚至更高)的噪声。人们正常讲话的声音大约是60-70dB,大声呼喊的瞬间可达100dB。在机器轰鸣的厂房中,持续的噪声可达80-110dB,这种高强度的噪声会损害人耳的听觉,并对神经系统产生不良影响,长期还会导致神经衰弱、消化不良、听力下降、心血管等疾病。人耳的噪声听觉上限是120dB,超过120dB的声音会耳痛、难以忍受,140dB的声音会使人失去听觉。高分贝喇叭、重型机械、喷气飞机引擎等都能够产生超过120dB的声音。 1.2 人耳的感觉 人耳听觉非常敏感,正常人能够察觉1dB的声音变化,3dB的差异将感到明显不同。人耳存在掩蔽效应,当一个声音高于另一个声音10dB时,较小的声音因掩蔽而难于被听到和理解,由于掩蔽效应,在90-100dB的环境中,即使近距离讲话也会听不清。人耳有感知声音频率的能力,频率高的声音人们会有“高音”的感觉,频率低的声音人们会有“低音”的感觉,人耳正常的听觉频率范围是20-20KHz。人耳耳道类似一个2-3cm的小管,由于频率共振的原因,在2000-3000Hz的范围内声音被增强,这一频率在语言中的辅音中占主导地位,有利于听清语言和交流,但人耳最先老化的频率也在这个范围内。一般认为,500Hz以下为低频,500-2000Hz为中频,2000Hz以上为高频。语言的频率范围主要集中在中频。人耳听觉敏感性由于频率的不同有所不同,频率越低或越高时敏感度变差,也就是说,同样大小的声音,中频听起来要比低频和高频的声音响。 1.3频率特性 声音可以分解为若干(甚至无限多)频率分量的合成。为了测量和描述声音频率特性,人们使用频谱。频率的表示方法常用倍频程和1/3倍频程。倍频程的中心频率是31.5、63、125、250、500、1K、2K、4K、8K、16KHz十个频率,后一个频率均为前一个频率的两倍,因此被称为倍频程,而且后一个频率的频率带宽也是前一个频率的两倍。在有些更为精细的要求下,将频率更细地划分,形成1/3倍频程,也就是把每个倍频程再划分成三个频带,中心频率是20、31.5、40、50、63、80、100、125、160、200、250、315、400、500、630、800、1K、1.25K、1.6K、2K、2.5K、3.15K、4K、5K、6.3K、8K、10K、12.5K、16K、20KHz 等三十个频率,后一个频率均为前一个频率的21/3倍。在实际工程中更关心人耳敏感的部分,大多数情况下考虑的频率范围在100Hz到5KHz。噪声治理中一般采用倍频程。如果将声音的频率分量绘制成曲线就形成了频谱。 不同声源发出噪声有不同的频率特性,有些噪声低频能量很大,如气泵、齿轮转动机器等,有些声源中频能量很大,如轴承、冷却塔淋水声,有些噪声高频能量很大,如交直流电机、变压器、阀门等,但大多噪声往往是各种频率都有很大声音,而且没有任何规则。对于各种声学材料来讲,不同频率条件下声学性能是不同的。有的材料具有良好的高频吸声性能,有的材料具有良好的低频吸声性能,有的材料对某些频率具有良好的吸声性能,不一而同。隔声等其他声学性能也是如此。

交流毫伏表

交流毫伏表是一种用来测量正弦电压有效值的电子仪表,可对一般放大器和电子设备进行测量。毫伏表类型较多,本小节主要介绍wYx94交流毫伏表的主要特性并说明它的使用方法。 1拖述 wY2294双通道交流毫伏表是由两组相同的高稳定的放大器电路及表头指示电路等组成。其表头采用同轴双指针式电表。可十分清晰、直观的进行双路交流电压的测量和比较。该仪表输入端RJ设置于浮置状态,并且两通道的量程可同步选择。这样使该仪表的测量应用范围扩大,特别是立体声双通道的测量带来极大的方便。 该仪表具有频率响应范围宽(5H”1MH2)、灵敏度高(300Pv满刻度)、输入阻抗高(10M11)、本机噪声低、精确度高(‘2%)的优点,并具有相当好的线性度。 该仪表的外形美观,由于采用先进的电控衰减电路。使开关手感舒适。内部结构紧凑,可靠性好,可广泛应用于学校实验室、设计开发等领域。 (5)输入阻抗:1MO/40PE(不也括双央电缆线电容)。 (6)闭合误差:以1kIIz为基准。 ①电压测量误效:*2%。 ②频率响应误差:20Hz—l00kHzl3%;5Hz—1MHz』5% (7)工作误差。 ①电压测旦误差:15% ②频率影8自洪差:20Hz—100LH2*5% (8)输出特性。 ①输69l电压:1凹mv(当指小满刻度时)。 ②输出阻抗:约6000。 ②失克:事3%。 3下作原理 本机出输入衰减器、前置放大器、电子衰减器、主放大器、线性检波器、输出放大器及电源组 成,其力框图见图A11。前省放大器是由高输入阻抗及低输出阻抗的复合放大电路构成。由于采 用厂低噪声器件及]:艺措施,因此具有很小的本机暇声。输人端还具有过载保护电路。 低压电机电子衰减器有集成电路构成,受控制开关控制,因此具有较高的可靠性及

毫伏表操作规程标准范本

操作规程编号:LX-FS-A73018 毫伏表操作规程标准范本 In The Daily Work Environment, The Operation Standards Are Restricted, And Relevant Personnel Are Required To Abide By The Corresponding Procedures And Codes Of Conduct, So That The Overall Behavior Can Reach The Specified Standards 编写:_________________________ 审批:_________________________ 时间:________年_____月_____日 A4打印/ 新修订/ 完整/ 内容可编辑

毫伏表操作规程标准范本 使用说明:本操作规程资料适用于日常工作环境中对既定操作标准、规范进行约束,并要求相关人员共同遵守对应的办事规程与行动准则,使整体行为或活动达到或超越规定的标准。资料内容可按真实状况进行条款调整,套用时请仔细阅读。 使用注意事项 1、避免仪器过冷或过热,仪器的工作温度为0—40℃。 2、仪器不可遭到强烈的撞击。 3、不可将物体放置在仪器上,注意不要堵塞仪器通风孔。 4、不可将磁铁靠近表头。 5、表面长期倒置存放和运输。 6、检查表针位置,若不在零点先调零。 7、仪器工作电压为AC220V,不可高于规定的最大输入电压。

使用方法 1、开机前,应将量程旋钮调到最大量程处,然后打开电源。 2、将输入信号由输入端口(INPUT)送入交流毫伏表。 3、调节量程旋钮,使表头指针指示位置在大于或等于满刻度的1/3处。 4、量程的使用方法:表头有两种刻度。其中1V作为0dB的dB刻度值,0.755V作为0dBm (1mW)的dBm刻度值。 5、功率或电压的电平由表面读出的刻度值与量程开关所在的位置相加而定。 保养和维护 1、本仪器由高精度的元器件及精密部件构成,

声音分贝

1.损伤听力 人们长期在噪声环境里生活和工作,将会损伤人的听力。战争时期的炮兵战士患耳聋症的人很多,因为巨大的炮声,能造成人耳膜和听觉神经的严重损伤。在不同噪声强度下,耳聋的发病率也不同。在80分贝以下的噪声环境里,工作40年不致耳聋,在80分贝以上,每增加5分贝,耳聋率增加10%。 2.干扰睡眠 环境中的噪声在30 - 40 分贝之间,人们会感到安静、舒适,利于睡眠和休息。当环境中的噪声超过50分贝时,就会干扰休息和睡眠。睡眠对人是极端重要的,它能使人体的新陈代谢得到调节,使大脑得到休息。使人消除疲劳,恢复体力,保证身体健康。但是,环境噪声将会影响人们睡眠的质量和数量。连续噪声可以减低睡眠的深度,使熟睡变为轻睡,睡眠质量降低,熟睡时间变短。突然的环境噪声可以使人惊醒,破坏睡眠状态。40分贝的连续噪声,可以使10%的人受到影响;70分贝使50%的人受到影响。突然的40分贝噪声,可以使10%的人从睡梦中惊醒;70分贝可以使70%的人惊醒。 3.干扰思维 环境里的噪声,干扰人们的正常交谈和思考。环境噪声超过55分贝,人们将会感到吵闹,统计结果表明,当环境噪声达到55分贝时,会有15%的人感到吵闹;50分贝时有6%的人感到吵闹;在45分贝以下,才能够使一般人感到安静。 4.对人体生理影响 环境噪声还影响人体的神经系统,出现头痛、睡眠障碍等神经衰弱症状,导致血压不稳,心律加快,肠胃功能紊乱,食欲下降,甲状腺机能亢进,代谢失调。 5.对人体心理影响 在噪声环境里,人们常常会感到烦恼、恐慌,容易激动、愤怒,失去理智。在工作中,导致精力不集中,容易发生事故。环境噪声里成长的儿童智力比安静环境里的儿童智力低20%。噪声环境可以导致孕妇胎儿畸形,儿童智力障碍。 6. 引发心血管病 日前,瑞典一项最新研究显示,如果长期暴露在60分贝以上的交通噪音中,容易患高血压,甚至可能因此患其他心血管疾病。 最新一期英国《环境健康》杂志刊登瑞典隆德大学医院的一项研究说,该医院对18岁至80岁的两万多名瑞典人进行了大规模调查,结果显示,对60岁以下的人来说,60分贝以上交通噪音环境与患高血压之间有明显关联。60岁至80岁人群面临的其他许多风险因素相比,噪音的影响已相对下降。

分贝、声功率、声强和声压

分贝、声功率、声强和声压 频率:声源在一秒中内振动的次数,记作f。单位为Hz。 周期:声源振动一次所经历的时间,记作T,单位为s。T=1/f。 波长:沿声波传播方向,振动一个周期所传播的距离,或在波形上相位相同的相邻两点间距离,记为λ,单位为m。 声速:声波每秒在介质中传播的距离,记作c,单位为m/s。声速与传播声音的介质和温度有关。在空气中,声速(c)和温度(t)的关系可简写为:c = 331.4+0.607t常温下,声速约为345m/s。 频率f、波长λ和声速c三者之间的关系是: c = λf当物体在空气中振动,使周围空气发生疏、密交替变化并向外传递,且这种振动频率在20-20000Hz之间,人耳可以感觉,称为可听声,简称声音,噪声监测的就是这个范围内的声波。频率低于20Hz的叫次声,高于20000Hz的叫超声,它们作用到人的听觉器官时不引起声音的感觉,所以不能听到。 人们日常生活中遇到的声音,若以声压值表示,由于变化范围非常大,可以达六个数量级以上,同时由于人体听觉对声信号强弱刺激反应不是线形的,而是成对数比例关系。所以采用分贝来表达声学值。所谓分贝是指两个相同的物理量(例A1和A0)之比取以10为底的对数并乘以10(或20)。N = 10lg(A1/A0) 分贝符号为"dB",它是无量纲的。式中A0 是基准量(或参考量),A是被量度量。被量度量和基准量之比取对数,这对数值称为被量度量的"级"。亦即用对数标度时,所得到的是比值,它代表被量度量比基准量高出多少"级"。 (二)声功率(W) 声功率是指单位时间内,声波通过垂直于传播方向某指定面积的声能量。在噪声监测中,声功率是指声源总声功率。单位为W。 声功率级: Lw =10lg(W/W0) 式中:Lw——声功率级(dB); W——声功率(W); W0——基准声功率,为10-12 W。 (三)声强(I) 声强是指单位时间内,声波通过垂直于传播方向单位面积的声能量。单位为W / m2。 声强级: LI = 10lg(I/I0)式中:LI ——声压级(dB); I ——声强(W/m2); I0 ——基准声强,为10-12 W/m2。 (四)声压(P) 声压是由于声波的存在而引起的压力增值。单位为Pa。声波在空气中传播时形成压缩和稀疏交替变化,所以压力增值是正负交替的。但通常讲的声压是取均方根值,叫有效声压,故实际上总是正值,对于球面波和平面波,声压与声强的关系是:I= P2 / ρc式中:ρ-空气密度,如以标准大气压与20℃的空气密度和声速代入,得到ρ?c =408 国际单位值,也叫瑞利。称为空气对声波的特性阻抗. 声压级: LP = 20lg(P/P0) 式中:LP——声压级(dB); P ——声压(Pa);

分贝转换

分贝转换小常识 我们把常用的单位,不同的称呼转换告诉大家方便使用 公式:dBm=10logW/1mW dBμ=20logV/1μV db=20logX/10dbm=1mW 0dBμ=1μV 常用的几个标准是:50Ω负载时-47dbm=1mV, 0dbm=107dbμ=110mV13dbm=1V=120dbμ 分贝转换小常识公式: dBm=10logW/1mW dBμ=20logV/1μV db=20logX/1 0dbm=1mW 0dBμ=1μV 常用的几个标准是: 50Ω负载时47dbm=1mV 0dbm=107dbμ=110mV 13dbm=1V=120dbμ. 单位转换探讨 1 基础知识 1.1 用于构成十进制倍数和分数单位的词头(词冠) 词头中文名词头英文名符号所表示的因数词头中文名词头英文 名符号所表示的因数 分 deci d 10-1 皮 pico p 10-12 厘 centi c 10-2 千 kilo K 103 毫 milli m 10-3 兆 mega M 106 微 micro μ 10-6 吉 giga G 109 纳 nano n 10-9 太 tera T 1012 为不失一般性,下面的一些公式中将以希腊字母Θ代表无词头和十进制分数单位的词头(m、μ、n、p)。但一定要注意Θ本身并不是一种词头,仅是本文为避免列出大量雷同的公式而约定的一个符号而已。所以,当您看到Θ时,一定要想到它就是m、μ、n、p或者是没词头;在您需要含无词头单位参数的公式时,就请把Θ去掉;而在您需要含某种词头单位参数的公式时,就就请把Θ换成所需的词头。 1.2 分贝 在电子学中,分贝是表示传输增益或传输损耗以及相对功率比等的标准单位,其代号为dB(英文decibel的缩写)。其形式上表示倍数,实质上既能表示经作常用对数压缩处理后的倍数(以分贝表示的传输增益和传输损耗等,特点是本质无量纲),又能表示约定基准值的参数值(电压电平、功率电平,以分贝表示的电场强度、功率通量密度,杂散辐射功率和邻道功率相对于载波功率的电平等,特点是本质有量纲)。采用的根本原因在于对数运算能够压缩数据长度和简化运算(将乘、除、指数运算分别转化为加、减、乘运算),特别适合表达指数变化规律。我们这里约定,以符号lg表示以10为底的对数。经作对数变换后的本质有量纲单位常称作电平单位(与其基准值相等的参数值称零电平。电平的单位还有贝尔和奈培两种,但由于文献[1]规定“统一使用分贝为电信传输单位”,这里不采用。以下所称电平均以分贝为词头),而原来的单位可称作线性单位。