红外测温系统的设计_设计说明

红外测温系统的设计_设计说明
红外测温系统的设计_设计说明

摘要

到目前位置,我国的温度测量仪器仍然是以水银温度计为主,这种测量仪器存在很多缺点,如精度低,测量时间长,不安全等。本课题所研究的红外测温系统能实现人体温度的近距离或远距离准确测量。该设计以STC89C52单片机为核心部件。利用非接触式温度传感器OTP-538U对温度进行采样。得到的电信号经过四运算放大器芯片LM324前置放大后送至A/D模块,A/D采用12位高精度的TLC2543芯片,数字信号传送到主控芯片STC89C52,并由微处理器完成数据采集和转换,实现温度的实时测量并实时显示在LCD1602模块上。

本文所研究的非接触传感器单片机测温系统由于对被测物体的红外辐射进行的是非接触无损测量,测量过程中不会扰乱被测部分的温度场,响应快,温度分辨率高,稳定性好和使用寿命长等一系列的优点,比传统的接触式测温有更多的场合适应性。

关键词:STC89C52;非接触传感器;LM324;红外辐射

ABSTRACT

So far ,our country’s temperature measuring instrument is still a mercury thermometer mainly. This kind of measuring instrument has many shortcoming,such as low accuracy.measuring time long,unrest congfigruent.The subject of the infrared temperature system can realize the body temperature close distanceor distance measured accurately.The design for the STC89C52 single-chip microcomputer as the core component. Use contact-less temperature preach OTP-538U temperature in sampling.Operational amplifier chip LM324 will sent electrical signals to the A/D module after pre-amplification,A/D and 12 of the high accuracy of TLC2543 chip,digital signals to control STC89C52core,and the microprocessor complete data collection and conversion,realize real-time temperature measurement and real –time display to LCD1602 module.

This paper studies the contact signal-chip microcomputer temperature measurement system because of the object to be tested for infrared radiation is the contact nondestructive measurement, the measurement process won’t disrupt the measured part of the temperature field,fast response,temperature high resolution,good stability and long service life and a series of asvantages,than traditional contact temperature measurement have more situations adaptability.

KEY WORDS : STC89C52;Non contact sensor;LM324;Infrared radiation

目录

第1章绪论 (1)

研究课题背景 (1)

第2章红外测温仪概述 (2)

2.1 红外测温仪简介 (2)

第3章系统硬件设计 (4)

3.1 硬件设计概述 (4)

3.2 单片机STC89C52模块 (5)

3.2.1 MCS-51单片机部结构 (5)

3.2.2 STC89C52RC单片机介绍 (5)

3.2.3 STC89C52RC单片机的工作模式 (6)

3.2.4 STC89C52RC引脚功能说明 (7)

3.2.5 看门狗应用 (10)

3.3红外测温模块 (10)

3.3.1特性 (10)

3.3.2 应用 (10)

3.3.3 传感器特性 (11)

3.3.4实用连接电路图 (13)

3.4 放大电路模块 (14)

3.4.1 LM324的引脚排列 (14)

3.4.2 参数与描述 (14)

3.4.3特点 (15)

3.4.4 应用电路 (16)

3.5 A/D转换模块 (17)

3.5.1 TLC2543的特点 (17)

3.5.2 TLC2543的引脚排列及说明 (17)

3.5.3 接口时序 (18)

3.5.4 应用电路 (20)

3.6 电源模块 (20)

3.6.1整流桥 (21)

3.6.2 应用电路图 (22)

3.7 液晶显示模块 (22)

3.7.1 管脚功能 (23)

3.7.2 特性 (24)

3.7.3 应用电路 (25)

第4章系统软件设计 (26)

4.1 总体设计 (26)

4.2 A/D转换单元时序 (27)

4.2.1 TLC2543控制字 (27)

4.2.2 工作流程 (28)

4.3 LM324模块 (31)

4.4 红外传感器模块 (32)

4.5 LCD1602显示模块 (33)

4.5.1 1602LCD的指令说明及代码解释 (33)

4.5.2 液晶显示模块程序流程图 (36)

第5章总结 (37)

致 (38)

第1章绪论

研究课题背景

温度是确定物质状态的重要参数之一,它的测量与控制在国防、军事、科学研究以及工农业生产中占有十分重要的地位。在工业生产中,我们需要经常对设备的运行状况进行监测来确保设备的安全运行,而对设备的监测通常通过测量其表面的温度来进行。现代的工业设备往往是在高电压、大电流以及其它危险情况下运行的,传统依靠人工接触式检测的方法既浪费时间、物力、人力,又带有一定的危险性,同时对测温仪所采用的材质也有严格的限制,在这样的场合下,仪器的使用寿命也成为设计接触式测温仪时的一个重点考虑问题。因此有必要去应用一种新的方式去检测目标系统的温度,确保设备的平稳运行。温度的测量方法有两类,一种是利用电气参数随温度变化特性的热电阻、热电偶测温法以及以膨胀式温度计为代表的接触式测温方法,另一种是以热辐射为代表的非接触式测温方法。前者的优点在于测得的温度是物体的真实温度,测温简单、可靠,其缺点在于动态性能差,需要接触被测物体,测温元件与被测介质需要一定时间的热交换才能达到热平衡,同时对被测物体的温度场分布有一定的影响,同时由于工业现场的高温、高压、腐蚀性等恶劣条件,影响了测温仪的精度和使用寿命,大大限制了接触式测温仪的使用;非接触式测温也叫辐射测温,一般使用热电型或光电探测器作为检测元件,其与接触式测温相比,具有响应时间短、非接触、不干扰被测温场、使用寿命长、操作方便等一系列优点,但受到物体的发射率、测温距离、烟尘和水蒸气等外界因素的影响,其测量误差较大。目前应用最广泛的非接触式测量仪是红外测温仪,它测温的理论基础是黑体辐射定律。自然界的任何物体都在不停的向外辐射能量,物体辐射能量的大小及波长的分布与其表面的温度有着十分密切的关系,通过测量物体自身红外辐射的能量便能确定它的表面温度。

第2章红外测温仪概述

2.1 红外测温仪简介

红外测温仪是一种将红外技术与微电子技术结合起来的一种新型测温仪器,它通过将被测物表面发射的红外波段辐射能量通过光学系统汇聚到红外探测原件上,使其产生一个电压信号,经过放大、模/数转换等环节处理,最后以数字形式直接在显示屏上显示温度值。红外测温仪由光学部分和信号处理部分组成,其体积小,便于携带,操作简单,在各行各业中得到广泛应用。

2.2 红外线测温仪的优点

与传统接触式温度计相比而言,红外线测温仪有着响应时间快、使用安全、非接触及使用寿命长等优点。

(1)精确。红外线测温仪精确,通常精度都是1度以,这种性能在做预防性维护时特别重要。用红外测温仪,你甚至可快速探测操作温度的微小变化,在其萌芽之时就可将问题解决,减少因设备故障造成的开支和维修的围。

(2)便捷。红外线测温仪的另一个先进之处是可快速提供温度测量,在用热偶读取一个渗漏连接点的时间,用红外测温仪几乎可以读取所有连接点的温度。另外由于红外测温仪坚实、轻巧(都轻于10盎司),且不用时易于放在皮套中。所以当你在工厂巡视和日常检验工作时都可携带。

(3)安全。安全是使用红外线测温仪最重要的好处。不同于接触测温仪,红外线测温仪能够安全地读取难以接近的或不可到达的目标温度,在仪器允许的围读取目标温度。非接触温度测量还可在不安全的或接触测温较困难的区域进行,像蒸汽阀门或加热炉附近,他们不需在冒接触测温时一不留神就烧伤手指的风险。高于头顶25英尺的供/回风口温度的精确测量就象在手边测量一样容易。红外测温仪具有激光瞄准,便于识别目标区域。

2.3 红外测温仪工作原理及测温方法

红外测温仪由光学系统、光电探测器、信号放大器及信号处理、显示输出等部分组成。光学系统汇聚其视场的目标红外辐射能量,视场的大小由测温仪的光学零件及其位置确定。红外能量聚焦在光电探测器上并转变为相应的电信号。该信号经过放大器和信号处理电路,并按照仪器疗的算法和目标发射率校正后转变为被测目标的温度

红外线测温仪原理及应用

红外线测温仪原理及应用 摘要:测量温度的方法有很多种,温度计大致可以分为接触式测温仪表和非接触式测温仪表两类。其中接触式的有我们熟悉的液体式温度计,热电偶式温度计和 热电阻式温度计等等。 关键词:红外线测温辐射光纤 众所周知,温度是供热,供燃气,通风及空调系统中最重要的参数之一。尤其在热工测量过程中,温度的精准程度往往是决定实验成败的关键。因此,一个精确度高的测温仪器在工程中是必不可少的。因此本文就温度测量工具中的红外线测温仪的原理及应用进行一些介绍。 一,红外测温的理论原理 在自然界中,当物体的温度高于绝对零度时,由于它内部热运动的存在,就会不断的向四周辐射电磁波,其中就包含了波段位于0.75μm~100μm的红外线。他最大的特点是在给定的温度和波长下,物体发射的辐射能有一个最大值,这种物质称为黑体,并设定他的反射系数为1,其他的物质反射系数小于1,称为灰体,由于黑体的光谱辐射功率P(λT)与绝对温度T之间满足普朗克定。说明在绝对温度T下,波长λ处单位面积上黑体的辐射功率为P(λT)。根据这个关系可以得到图1的关系曲线,从图中可以看出: (1)随着温度的升高,物体的辐射能量越强。这是红外辐射理论的出发点,也是单波段红外测温仪的设计依据。 (2)随着温度升高,辐射峰值向短波方向移动(向左),并且满足维恩位移定理,峰值处的波长与绝对温度T成反比,虚线为处峰值连线。这个公式告诉我们为什么高温测温仪多工作在短波处,低温测温仪多工作在长波处。 (3)辐射能量随温度的变化率,短波处比长波处大,即短波处工作的测温仪相对信噪比高(灵敏度高),抗干扰性强,测温仪应尽量选择工作在峰值波长处,特别是低温小目标的情况下,这一点显得尤为重要。 二,红外线测温仪的原理

非接触式测温仪设计与制作

非接触式测温仪的设计与制作 田云,黑龙江农业经济职业学院 本文介绍一种采用凌阳公司生产的TN9红外测温传感器来实现红外测温,控制器采用大家熟悉的51单片机。所有物体都会发出红外线能量。物体越热,其分子就愈加活跃,它所发出的红外线能量也就越多。红外线温度仪包括有光学装置,可以收集来自物体的辐射红外线能量,并把该能量聚焦在探测器上。能量经探测器转化为电信号,并被放大、显示出来。红外测温打破了传统的接触式测温模式,它根据被测物体的红外辐射能量来确定物体的温度,不与被测物体接触,具有不扰动被测物体温度分布场,温度分辨率高、响应速度快、测温范围广,稳定性好、可同时测量环境温度和目标温度的特点。近年来在汽车电子、航空和军事上得到越来越广泛的应用。 一、红外测温传感器TN9 红外测温传感器选用凌阳科技公司生产的TN9红外测温传感器,可测量目标温度和环境温度。它采用非接触测温手段,解决了传统测温中需要接触的问题,具有回应速度快、测量精度高、测量范围广以及可同时测量目标温度和环境温度的特点。红外测温模块根据大气状况最远测温距离约 30m,测量回应时间大约为 0.5s,而且,它具备 SPI接口,可以很方便地与单片机传输数据。外型如图1所示,它的基本特性如表1所示。 量程-33-220℃/-27-428℉ 工作温度-10-50℃/14-122℉ 精度±0.6℃ 反应时间1sec 重量8g 电压范围3V- 5V 图1 TN9红外测量传感器外型

1、红外测温传感器引脚 红外测温模块的引脚如图2所示。其中V为电源电压引脚VCC,VCC一般为 3V到 5V之间的电压;D为数据接收引脚,没有数据接收时D为高电平;C为 2KHz Clock输出引脚(这里需要注意,只有为TN9供上电源,C脚就有2KHz的方波信号输出);G为接地引脚;A为测温启动信号引脚,低电平有效。 图2 TN9红外测温传感器引脚 2、红外测温模块的工作时序 TN9红外模块的工作SPI时序如图3所示。 从时序图可以看出: TN9红外传感器向单片机发送一帧数据共有5个BYTE组成,每个BYTE位的含义如下: Item :如果为4CH代表此帧测量为目标温度,为66H代表此帧测量为环境温度。 MSB :数据高八位 LSB :数据低八位 SUM :校验位 SUM=Item+MSB+LSB CR :0DH为结束码 单片机在CLOCK的下降沿接收数据,一次温度测量需接收 5 个字节的数据,这五个字节中:Item为 0x4c表示测量目标温度,为 0x66 表示测量环境温度;MSB为接收温度的高八位数据;LSB为接收温度的低八位数据;Sum为验证码,接收正确时Sum=Item+MSB+LSB;CR 为结束标志,当CR为 0x0dH时表示完成一次温度数据接收。

红外测温仪应用领域

红外测温仪应用领域 任何一个无法接触到的区域如果需要温度测量的话,红外测温仪可以测量表面温度可以实现非接触式测量,红外测温仪可测量的温度范围也比较大。红外测温技术已发展到可对有热变化表面进行扫描测温,确定其温度分布图像,迅速检测出隐藏的温差。由于红外测量的本质决定了红外更多的被应用于工业领域。红外温度计被普遍的用在钢铁,玻璃和塑料工业。他们也被广泛的应用于预防设施中。 一、在钢铁工业 钢铁工业使用温度计是因为产品都是处于运动状态,温度都非常高。普通的钢铁工业应用是温度是一个持续的状态熔化的钢铁开始转变成块。用同一的温度重新加热钢铁是防止它变形的关键,红外温度计被用来测量回热器的内部温度。在高温旋转轧碾机中,红外温度计被用来确认产品的温度是在旋转限度内。在冷却轧碾机,红外温度计在钢铁冷却的过程中来监控钢铁的温度。 二、红外测温仪在玻璃工业 在玻璃工业中,要被加热到很高的温度。红外温度计用来监测熔炉中的温度。手持式的传感器通过测量外部来探测高温点。测量溶化玻璃的温度来决定适当的熔炉口的温度。在扁平的玻璃品中,传感器在每个加工阶段都要检测温度。错误的温度或过快的温度变化会造成不平的膨胀或收缩。对于瓶子和容器产品来说,熔化的玻璃会流向保持在同一温度的前炉。红外温度计被用来探测前炉的玻璃的温度。所以它在出口的地方应该是适当的状态。在玻璃纤维制品,红外传感器被用来在加工炉中探测前炉的玻璃的温度。红外传感器在玻璃工业中另外一个用途是用于挡风玻璃制品工艺中。 三、在塑料工业 在塑料工业中,红外温度计被用来避免产品被玷污,测量动态物体和测量高温塑料。在吹制的薄膜喷出的过程中,温度测量来调整适应加热和冷却可以帮助保持塑料的张力的完整和它的厚度。在抛制的薄膜喷出的过程中,传感器帮助控制温度来保证产品的厚度和同一。在薄片压出时,传感器可以让操作员来调整熄灭的加热器和冷卷来保证产品的质量。 四、化学工业 在石化行业中,炼厂在常规的预防维护程序中采用温度显示系统。这些程序

红外测温仪技术方案设计

红外测温仪 技 术 案

北京市科海工业自动化仪器有限公司 2018年01月19日 一.概述 1、设备名称和型号: 1)设备名称:红外测温仪 2)设备型号:WFD-600-GZ 2、测温仪表简介: WFD-600-GZ系列红外测温仪是一种智能化、高精度、非接触式数字显示测温仪表,具有测温速度快、使用寿命长等优点。它利用被测物体的红外辐射能量精确测量物体的温度,测量距离与被测目标的大小成正比。仪表显示读数直观,可配置各种接口、性能稳定、操作简单,安装与调整便。 WFD-600-GZ型红外测温仪,是可根据用户需要定做不同温度段的测温仪,测温仪具有较高的灵敏度,测斑适中。同时根据现场需求,设备配有冷却装置,能够快捷、安全、稳定的测量被测物温度。 二.技术指标 1、供电电压:交流220V供电,50Hz,20W或24V/DC 2、测温围:900~2000℃ 3、输出信号:4-20mA和RS485标准信号 4、测量精度:±1%满量程 5、重复精度:±0.2%满量程 6、响应时间:<1秒(根据现场条件可调整) 7、距离系数:L/D=100 8、显示式:4位LED发光数码管显示平均值、峰值、实时值(选其中一种) 9、温度分辨率:1℃

10、工作波长:0.7~1.1μm或1.1~1.7μm 11、辐射系数:0.1~1.0连续可调 12、气源压力:0.2~0.6MPa 13、气源流量:4~6m3/h 14、使用环境:见表一 15、重 三.技术特点 1、具有光学瞄准系统,采用固定焦距加分划板瞄准,可以便找到被测目标 确保测量位置准确。 2、红外测温仪探头自身耐环境温度达90℃,这就大大延长了使用寿命。 3、显示式具有实时值、平均值、峰值和自动环境温度补偿。 4、电路采用8位单片机作中央处理器并采用CMOS电路,使整机工作电流 小,工作稳定可靠。 5、输出接口:4-20mA(对应围可设定)连接到PLC或RS485信号连接大屏 幕显示器。 6、红外测温系统结构简单,由红外探头、信号处理器、信号电缆组成。 7、设计成分体结构,避开高温区,维修调试便。 8、测温探头带有气源冷却装置,减少物镜灰尘,保证测量精度。 9、红外测温探头工作在短波段,对窗口污染有较好的适应性,窗口透过率 降低36%,测温示值仅降低4%。

红外线测温仪的使用方法

引用红外线测温仪的使用方法 lao wu tong 的红外线测温仪的使用方法 红外线测温仪的理论原理和应用 摘要:测量温度的方法有很多种,温度计大致可以分为接触式测温仪表和非接触式测温仪表两类。其中接触式的有我们熟悉的液体式温度计,热电偶式温度计和热电阻式温度计等等。 关键词:红外线测温辐射光纤 众所周知,温度是供热,供燃气,通风及空调系统中最重要的参数之一。尤其在热工测量过程中,温度的精准程度往往是决定实验成败的关键。因此,一个精确度高的测温仪器在工程中是必不可少的。因此本文就温度测量工具中的红外线测温仪的原理及应用进行一些 介绍。 一,红外测温的理论原理 在自然界中,当物体的温度高于绝对零度时,由于它内部热运动的存在,就会不断的向四周辐射电磁波,其中就包含了波段位于 0.75μm~100μm的红外线。他最大的特点是在给定的温度和波长下,物体发射的辐射能有一个最大值,这种物质称为黑体,并设定他的反射系数为1,其他的物质反射系数小于1,称为灰体,由于黑体的光

谱辐射功率P(λT)与绝对温度T之间满足普朗克定。说明在绝对温 度T下,波长λ处单位面积上黑体的辐射功率为P(λT)。根据这个 关系可以得到图1的关系曲线,从图中可以看出: (1)随着温度的升高,物体的辐射能量越强。这是红外辐射理论的出发点,也是单波段红外测温仪的设计依据。 (2)随着温度升高,辐射峰值向短波方向移动(向左),并且满足维恩位移定理,峰值处的波长与绝对温度T成反比,虚线为处峰值连线。这个公式告诉我们为什么高温测温仪多工作在短波处,低温测温仪多工作在长波处。 (3)辐射能量随温度的变化率,短波处比长波处大,即短波处工作的测温仪相对信噪比高(灵敏度高),抗干扰性强,测温仪应尽量选择工作在峰值波长处,特别是低温小目标的情况下,这一点显得尤为重要。 二,红外线测温仪的原理 红外测温仪由光学系统、光电探测器、信号放大器及信号处理、显示输出等部分组成。被测物体和反馈源的辐射线经调制器调制后输入到红外检测器。两信号的差值经反放大器放大并控制反馈源的温度,使反馈源的光谱辐射亮度和物体的光谱辐射亮度一样。显示器指出被测物体的亮度温度 三,红外线测温仪的性能指标及作用

红外测温仪开题报告

毕业设计(论文)开题报告表 学生姓名学号090201042 所在学院信息学院专业、班级 指导教师指导教师单位 指导教师指导教师单位 毕业论文题目基于单片机红外测温仪的设计 开题报告内容 选题依据(选题经过,国内、国外研究现状,初步设想及突破点等)红外测温仪在工业领域广泛应用,但由于医用红外测温仪的特殊要求。1989 年以来,热释电耳道式测温仪才成功的用于体温测量,1991 年以后该产品已遍及欧美市场。我国在这方面的起步较晚。 2003 年,由中科院物理研究所王树铎教授研制的“非接触、口腔式红外线电子体温仪”才获得专利授权。在此之前,完全不与人体接触、又满足医疗测量精度要求的体温计还没有面世。 随着医疗技术的快速发展,人们对非接触、快速有效测温技术的需求越来越大,传统的接触式人体测温仪已经不能满足现代医用领域的测温需求。红外测温仪具有安全、可靠、非接触、快速、准确、方便、寿命长等方面不可替代的优势,已被越来越多的医疗行业认识和接受。 2003 年我国遭受非典型肺炎传染性疾病(SARS),2009 年全球甲型H1N1 流感的肆虐,这些事件的发生,使人们越来越注重公共卫生安全。非接触、高精度医用红外测温仪的研究,对于公共场合、大流量人群的快速检测具有重要的意义,它不仅具有巨大的商业价值,而且具有重大的社会价值。本次设计初步设想是设计一种基于51 单片机的热释电红外测温仪。它以黑体辐射定律作为理论基础,是光学理论和微电子学综合发展的产物。红外信号经过光学系统聚焦在热释电探测器上并转变为相应的电信号,此信号经过放大、滤波、A/D 转换,再送到单片机中进行数据的处理、补偿,最后送到液晶显示单元显示。红外测温仪是一种将红外技术与微电子技术结合起来的一种新型测温仪器,它通过将被测物表面发射的红外波段辐射能量通过光学系统汇聚到红外探测器件上,使其产生一个电压信号,该信号经过放大、滤波、模/数转换后送到微控制器中进行温度补偿与数据处理,最后将目标温度值以数字形式显示在显示屏上。

红外测温仪使用指南2

红外测温仪使用指南 红外测温仪是一种非接触式测温仪器,通过吸收被测物体发出的红外辐射来测量其温度。可1秒快速测温,达到快速筛查体温异常的目的,并防止交叉传染。 [种类] ●红外人体表面温度快速筛检仪 (红外筛检仪) 多点测温图像识别追踪,适用于机场口岸、地铁、车站、码头、医院等人流密集的场合,用于体温异常人员的快速筛查。 ●红外体表温度计(红外额温计) 适用于企事业单位、住宅、社区等人流较少的场合,适合移动巡检,目前大量应用于防疫控制中。 ●红外耳温计 通过耳腔和鼓膜测量体温,适用于家庭、个人及严格消毒的医院非发热普通门诊。 [准确性] 红外耳温计>红外额温计>红外筛检仪 [使用须知] ●红外筛检仪 1、通电预热,与环境达到热平衡后再使用; 2、避免强电磁干扰,无较大的气流,环境条件应保持恒定,温度不应有较大变化; 3、当被测者来自与测量环境温度差异较大时,建议等候(5~10)分钟,两者达到热平衡后再测量为佳; 4、保持设备的探测镜头干净整洁,避免触碰损伤镜头,影响测量准确性。 ●红外额温计 1、使用前确认“体温”测量模式; 2、保持额温计在(16~35)℃之间工作,使用时应避免阳光直晒和环境热辐射,额温计、被测者和环境温度保持热平衡为佳; 3、额温计应垂直于额头中心、眉心上方,其距离按说明书规定的要求一般为3~5cm,如未说明的按照3cm距离测量,不能紧贴被测者额头; 4、被测者前额应无水迹、汗渍、无化妆品,无帽子、毛发等遮挡物; 5、严格按照使用说明书进行操作。

●红外耳温计 1、测量前保持耳道清洁,清理耳垢等污物; 2、测量时对准耳道和鼓膜中心位置,不偏不移; 3、耳温计须配备一次性卫生耳套使用,避免多人使用交叉感染; 4、严格按照仪器使用说明书进行操作。 [遇到红外额温计数值不准怎么办?] 1、确认是否选择“体温”模式; 2、防止额温计长时间暴露在低温环境,一般不超过3分钟,要采取适当保温措施; 3、测量多次取平均值,一般两次测量数据之差不超过0.3℃; 4、人员长时间在寒冷环境下会导致额温偏低,可转移至温暖环境中复测; 5、如出现较大误差或异常情情况时,可用玻璃体温计或电子体温计核查进行数据修正。 ●简易修正方法: 第一步:在相同环境条件下,同时用玻璃体温计(或电子体温计)和红外额温计测量多名健康人员的体温,可测量多次,分别记录玻璃体温计(或电子体温计)和红外额温计测量平均值,两者的差距为修正值; 第二部:使用红外额温计测量时,测量值加上修正值即为人员体温。 [温馨提示] 1、红外测温仪可用于初筛,一旦发现体温异常,应使用经玻璃体温计或医用电子体温计进行二次确认,作为诊断最终依据。 2、如发现红外测温仪数据误差大、示值重复性差、性能不稳定的,则建议停止使用,送计量技术机构校准,并结合校准数据使用,以减少测量误差。 3、测量前20~30分钟要避免剧烈运动、进食、喝酒、喝冷水或热水、冷敷或热敷。测量时须严格按照仪器使用说明执行。

非接触式红外测温仪设计

非接触式红外测温仪设计 摘要 温度测量技术应用十分广泛,而且在现代设备故障检测领域中也是一项非常重要的技术。但在某些应用领域中,要求测量温度用的传感器不能与被测物体相接触,这就需要一种非接触的测温方式来满足上述测温需求。本论文正是应上述实际需求而设计的红外测温仪。 红外测温仪是以黑体辐射定律作为理论基础,是光学理论和微电子学综合发展的产物。与传统的测温方式相比,具有响应时间短、非接触、不干扰被测温场、使用寿命长、操作方便等一系列优点。 本文介绍了红外测温仪测温的基本原理和实现方法,提出了以STC89C51单片机为其核心控制部件的红外测温系统。详细介绍了该系统的构成和实现方式,给出了硬件原理图和软件的设计流程图。该系统主要由光学系统、光电探测器、显示输出等部分组成。光学系统汇集其视场内目标的红外辐射能量,红外能量聚焦在光电探测仪上并转变为相应的电信号。STC89C51单片机负责控制启动温度测量、接收测量数据、并按照单片机中的温度值计算算法计算出目标的温度值再通过LED把结果显示出来。 关键词: STC89C51单片机,红外测温,LED显示

THE DESIGN OF NON-CONTECT INFRARED THERMOMETER ABSTRACT The technology of temperature measurement is used widespread, and it also important in the modern equipment failure examination field. But in some application domains, we needn’t the sensor contact with the measured object which used in temperature measurement, this needs a kind of non-contact temperature measurement to satisfies the demand and the design of this infrared thermometer is also based on the demand. Infrared thermomter, it uses the blackbody radiation laws as the theories foundation, it is the outcome that the optical theories and micro-electronics learn a comprehensive development. Compared to the way of traditional temperature measurement, it has a series of merits, such as short in response time, non-contact, noninterference to temperature field, long useful time and convenient operation, etc. The paper introduces the basic principle of infrared thermometer and the method of realization, puts forward infrared trermometer system with the STC89C51 MCU as the CPU. The paper introduces the composing and the method of that system in detail, and gives the hardware principle diagram and the design flow chart of the software. The system formed by the optical system, photoelectron detector,display and output partially. The optical system collects the infrared radiation energy of the object in its field of view, the infrared energy focusing on the instrument and transforms to the corresponding electrical signal. The STC89C51 MCU is used to start the temperature survey, data receive, count the value of the object temperature based on the arithmetic with in MCU and the result is displayed on LED.

红外测温仪设计方案

红外测温仪设计方案 红外测温仪已被证实是检测和诊断电子设备故障的工具。可节省大量开支,用红外测温仪,你可连续诊断电子连接问题和通过查找在DC电池上的输出滤波器连接处的热点,以检测不间断电源(UPS)的功能状态,你可检验电池组件和功率配电盘接线端子,开关齿轮或保险丝连接,防止能源消耗;由于松的连接器和组合会产生热,红外测温仪有助于识别回路中断器的绝缘故障。或监视电子压缩机;日常扫描变压器的热点可探测开裂的绕组和接线端子。 目录 1.红外测温仪的原理构造 2.红外测温仪的分类 3.红外测温仪的技术参数 1.红外测温仪的原理构造 红外测温仪是把从被测物接收的红外线,由透镜经过滤波器聚焦

在检波器上,检波器通过被测物辐射密度的积分,产生一个与温度成比例的电流或电压信号,在此后相连接的电器部件中,把此温度信号线性化,发射率区域的修正,及转换成一个标准的输出信号。原理上有便携式测温仪和固定式测温仪两种,因此,在选择合适的红外测温仪用于不同的测量点时,以下的特征将是主要的:1、瞄准器瞄准器有此作用,测温仪所指的测量块或测量点可以看见,大面积的被测物可以经常不要瞄准器。在小的被测物和较远的测量距离时,瞄准器以透光镜形式带有仪表板刻度或激光指向点是值得推荐的。2、透镜透镜确定测温仪的被测点,对大面积的物体来说,一般带有固定焦距的测温仪足够可以。但在测量距离远离聚焦点时,测量点边缘的图像将不清楚。为此,采用变焦镜更好,在所给予的变焦范围内,测温仪可调整测量距离,新的测温仪带有变焦的可替换镜头,近透镜和远透镜可不需校准复检进行更换。

2.红外测温仪的分类 红外线测温仪三大分类:(1)人用红外线测温仪:额温型红外线体温计(以下简称额温计)是一种利用红外接收原理测量人体的测温计。使用时,只须方便的将探测窗口对准额头位置,就能快速、准确的测得人体温度。(2)工业红外测温仪:工业红外测温仪测量物体的表面温度,其光传感器辐射、反射并传输能量,然后能量由探头进行收集、聚焦,再由其它的电路将信息转化为读书显示在机上,本机配备的激光灯更能对准被测物及提高测量精度。(3)畜牧业动物红外测温仪测温仪:兽用红外线非接触体温计根据普朗克原理,通过准确测定动物体表特定部位的体表温度,修正体表温度与实际温度的温差,便能准确显示出动物的个体体温。

红外测温仪操作使用方法

红外测温仪操作使用法 1.操作测温仪 测温仪会在按下扳机或按下黄色键时打开。若连续8秒钟没有检测到活动,测温仪会自动关闭。测量温度时,将测温仪瞄准目标,拉起并保持扳机按下不动。松开扳机以保持温度读数。一定要考虑距离与光点尺寸比以及视场。激光仅用于瞄准目标物体。 1)找出热点或冷点 要找出热点或冷点,将测温仪瞄准目标区域之外。然后,缓慢地上下移动以扫描整个区域,直到找到热点或冷点为止。见图 5。 图5 找出热点或冷点 2)距离与光点尺寸 随着与被测目标距离(D)的增大,仪器所测区域的光点尺寸(S)变大。光点尺寸表示 90 % 圆能量。当测温仪与目标之间的距离为 1000 mm(100 in),产生 20 mm(2 in)的光点尺寸时,即可取得最大 D:S。见图 6。 图6 距离与光点尺寸

3)视场 要确保目标大于光点的大小。目标越小,则应离它越近。(见图7) 图7 视场 4)发射率 发射率表征的是材料能量辐射的特征。大多数有机材料和涂漆或氧化处理表面的发射率大约为。如果可能,可用遮蔽胶带或无光黑漆(< 150 ℃/302℉)将待测表面盖住并使用高发射率设置,补偿测量光亮的金属表面可能导致的错误读数。等待一段时间,使胶带或油渍达到与下面被覆盖物体的表面相同的温度。测量盖有胶带或油漆的表面温度。 如果不能涂漆或使用胶带,可使用发射率选择器来提高您的测量准确度。即使是使用发射率选择器,对带有光亮或金属表面的目标也很难取得完全准确的红外测量值。 5)用户设置操作 SET键:循环切换设置状态,循环次序为发射率设定锁定测量设定℃/℉选择设定正常测量。按黄色键可直接保存设置并退出。 6)发射率设定 此功能为改变发射率的值。 设定时“E=0.”字样闪烁。 单击▲递加,长按快速增加,当加到后停止。 单击▼递减,长按快速减少,当减到后停止。 可根据不同被测物体设置相应的发射率。请参见表2。表所列的发射率设置为对典型情况的建议。您的特定情况可能有所不同。 7)锁定测量设定 此功能设定锁定测量打开或关闭,锁定测量打开后,无需抠扳机仪表保持正常测量;锁定测量关闭后,用户抠住扳机仪表正常测量,放开扳机仪表自动保持测量结果。设定时屏幕下显示“SET”及“on”或“oFF”。单击▲/▼循环选择“on” /“oFF”。 8)℃/℉选择设定 此功能选择仪表显示℃或℉。 设定时屏幕下显示“SET”。 单击▲/▼循环选择“℃”/ “℉”。 9)HAL限值设定 此功能为设定高限值操作,测量时温度高过此值时连续蜂鸣报警。 按黄色键切换至屏幕下显示“HAL”字样,单击▲递增,长按快速增加,当

红外测温仪技术规范

红外测温仪技术规范

目录 1. 范围 (3) 2. 引用标准 (3) 3.基本要求 (3) 4. 功能要求 (4) 5. 技术参数 (4) 6. 其它要求 (5) 7. 验收与培训 (6) 8. 售后服务 (6) 9.供货范围 (7)

1. 范围 1.1 本技术条件适用于桂林供电局红外测温仪的订货及验收的技术要求。 1.2 需求方在本规范书中提出了最低限度的技术要求,并未规定所有的技术要求和适用的标准,未对一切技术细则作出规定,也未充分引述有关标准和规范的条文,供方应提供一套满足本规范书和现行有关标准要求的高质量产品及其相应服务。 1.3 如果供方没有以书面形式对本规范书的条款提出异议,则意味着供方提供的设备(或系统)完全满足本规范书的要求。如有异议,不管是多么微小,都应在投标书中以“对规范书的意见和与规范书的差异”为标题的专门章节加以详细描述。 1.4 本设备技术规范书经需供双方确认后作为订货合同的技术附件,与合同正文具有同等的法律效力。 1.5 供方须执行现行国家标准和行业标准。 1.6 本设备技术规范书未尽事宜,由需供双方协商确定。 1.7 供方应获得ISO9000(GB/T 19000)资格认证书或具备等同质量认证证书,必须已经生产过30台以上或高于本招标书技术规范的设备,并在相同或更恶劣的使用条件下持续使用三年以上的成功经验。提供的产品应有省部级鉴定文件或等同有效的证明文件。 2. 引用标准 GB 2900电工名词术语 EN 61000-6-2: 2005通用抗扰度标准(第2部分):工业环境 IEC 60-2:1994高电压试验技术 GB/T 16927-1997高电压试验技术 EN 50082-2: 1992散射标准(居民、商业、轻工业环境) IEC 1000电磁兼容性 GB 4793-1984电子测量仪器安全要求 GB/T 2423.8-1995电工电子产品基本环境试验规程 3.基本要求 3.1 仪器的铭牌应标明制造厂家、型号、仪器名称、出厂编号等。 3.2 所有仪器应具备详细的中文说明书。 3.3 仪器必须保证测试准确度,仪器的工作电源必须保证测试过程的安全可靠。

红外扫描测温仪的应用范围

红外扫描测温仪的测温原理是将物体发射的红外线具有的辐射能转变成电信号,红外线辐射能的大小与物体本身的温度相对应,根据转变成电信号大小,可以确定物体的温度。下面由安徽锐光电子科技有限公司为您介绍下红外扫描测温仪的应用范围,希望能给您带来帮助。 红外扫描测温仪作为一种测量电器设备,可以非接触式的从安全的距离测量一个物体的表面温度,使其成为电器设备维修操作中不可缺少的工具。 红外扫描测温仪可以有效防止设备故障和计划外的断电事故的发生,其在电设备方面的应用表现为: 1.连接器-电连接部位会逐渐放松连接器,由于反复的加热(膨胀)和冷却(收缩)产生热量、或者表面脏物、炭沉积和腐蚀。非接触测温

仪可以迅速确定表明有严重问题的温升。 2.电动机-为了保持电动机的寿命期,检查供电连接线和电路断路器(或者保险丝)温度是否一致。 3.电动机轴承-检查发热点,在出现的问题导致设备故障之前定期维修或者更换。 4.电动机线圈绝缘层-通过测量电动机线圈绝缘层的温度,延长它的寿命。 5.各相之间的测量-检查感应电动机、大型计算机和其它设备的电线和连接器各相之间的温度是否相同。 6.变压器-空冷器件的绕组可直接用红外测温仪测量以查验过高的温度,任何热点都表明变压器绕组的损坏。 7.不间断电源-确定UPS输出滤波器上连接线的发热点。一个温度低的点表明可能直流滤波线路是开路。 8.备用电池-检查低压电池以确保连接正确。与电池接头接触不良可能会加热到足以烧毁电池芯棒。 9.镇流器-在镇流器开始冒烟之前检查出它的过热。 10.公用设施-确定出连接器、电线接头、变压器和其他设备的热点。某些型号的光学仪器范围在60:1甚至更大,使几乎所有的测量目标都在测量范围内。

红外测温仪操作使用方法

红外测温仪操作使用方法 1.操作测温仪 测温仪会在按下扳机或按下黄色键时打开。若连续8秒钟内没有检测到活动,测温仪会自动关闭。测量温度时,将测温仪瞄准目标,拉起并保持扳机按下不动。松开扳机以保持温度读数。一定要考虑距离与光点尺寸比以及视场。激光仅用于瞄准目标物体。 1)找出热点或冷点 要找出热点或冷点,将测温仪瞄准目标区域之外。然后,缓慢地上下移动以扫描整个区域,直到找到热点或冷点为止。见图 5。 图5 找出热点或冷点 2)距离与光点尺寸 随着与被测目标距离(D)的增大,仪器所测区域的光点尺寸(S)变大。光点尺寸表示 90 % 圆内能量。当测温仪与目标之间的距离为 1000 mm(100 in),产生 20 mm(2 in)的光点尺寸时,即可取得最大 D:S。见图 6。 图6 距离与光点尺寸 3)视场 要确保目标大于光点的大小。目标越小,则应离它越近。(见图7)

图7 视场 4)发射率 发射率表征的是材料能量辐射的特征。大多数有机材料和涂漆或氧化处理表面的发射率大约为 0.95。如果可能,可用遮蔽胶带或无光黑漆(< 150 ℃/302℉)将待测表面盖住并使用高发射率设置,补偿测量光亮的金属表面可能导致的错误读数。等待一段时间,使胶带或油渍达到与下面被覆盖物体的表面相同的温度。测量盖有胶带或油漆的表面温度。 如果不能涂漆或使用胶带,可使用发射率选择器来提高您的测量准确度。即使是使用发射率选择器,对带有光亮或金属表面的目标也很难取得完全准确的红外测量值。 5)用户设置操作 SET键:循环切换设置状态,循环次序为发射率设定锁定测量设定℃/℉选择设定正常测量。按黄色键可直接保存设置并退出。 6)发射率设定 此功能为改变发射率的值。 设定时“E=0.”字样闪烁。 单击▲递加0.01,长按快速增加,当加到1.00后停止。 单击▼递减0.01,长按快速减少,当减到0.10后停止。 可根据不同被测物体设置相应的发射率。请参见表2。表内所列的发射率设置为对典型情况的建议。您的特定情况可能有所不同。 7)锁定测量设定 此功能设定锁定测量打开或关闭,锁定测量打开后,无需抠扳机仪表保持正常测量;锁定测量关闭后,用户抠住扳机仪表正常测量,放开扳机仪表自动保持测量结果。设定时屏幕下方显示“SET”及“on”或“oFF”。单击▲/▼循环选择“on” /“oFF”。 8)℃/℉选择设定 此功能选择仪表显示℃或℉。 设定时屏幕下方显示“SET”。 单击▲/▼循环选择“℃”/ “℉”。 9)HAL限值设定 此功能为设定高限值操作,测量时温度高过此值时连续蜂鸣报警。 按黄色键切换至屏幕下方显示“HAL”字样,单击▲递增0.1,长按快速增加,当加到仪器最高测温值后停止并发声;单击▼递减0.1,长按快速减少,当减到仪器最低测温值或低于LAL限值后停止并发声。再按SET确认/取消此功能, 显示“”时此功能生效。

(完整版)红外测温传感器

红外光电传感器测温仪 1红外测温传感器结构 红外测温仪由光学系统、光电探测器、信号放大器及信号处理、显示输出等部分组成。光学系统汇聚其视场内的目标红外辐射能量,视场的大小由测温仪的光学零件及其位置确定。红外能量聚焦在光电探测器上并转变为相应的电信号。该信号经过放大器和信号处理电路,并按照仪器内的算法和目标发射率校正后转变为被测目标的温度值。 2红外测温传感器工作原理 在自然界中,一切温度高于绝对零度的物体都在不停地向周围空间发出红外辐射量。根

据基尔霍夫定律、普朗克定律、维恩公式这三大辐射定律,物体的红外辐射能量的大小及其按波长的分布与其表面温度有着十分密切的关系。因此,通过对物体自身辐射的红外能量的测量,便能准确地测定它的表面温度,这就是红外辐射测温所依据的客观基础。 三大辐射定律均是以“黑体”作为研究对象分析得出的。但是,自然界中存在的实际物体都不是黑体,所有实际物体的辐射量除依赖于辐射波长及物体的温度之外,还与构成物体的材料种类、制备方法以及表面状态和环境条件等因素有关。因此,为了使黑体辐射定律适用于所有实际物体,必须引入一个与材料性质及表面状态有关的比例系数,即发射率。该系数表示实际物体的热辐射与黑体辐射的接近程度,其值在0-1之间。根据辐射定律,只要知道了材料的发射率,就知道了任何物体的红外辐射特性。物体表面发射率主要决定于材料性质和表面状态( 如表面氧化情况,涂层材料,粗糙程度及污秽状态等)。 当物体的温度高于绝对零度时,由于它内部热运动的存在,就会不断的向四周辐射电磁波,其中的红外线在给定的温度和波长下,物体发射的辐射能有一个最大值,这种物质成为黑体,其他的波段的最大值成为灰体。事实上,自然界中并不存在黑体,只是为了获得红外线的分布规律才提出的,从而导出了普朗克黑体辐射定律。 普朗克黑体辐射定律是用于描述在任意温度下从一个黑体中发射的电磁辐射的辐射率与电磁辐射的频率的关系公式。通过对物体自身辐射的红外能量的测量,便能准确地测定它的表面温度,这就是红外辐射测温所依据的客观基础用公式可表达为: E=δε(T-To ) E 是辐射出射度.单位是W /m3; δ是斯蒂芬一波尔兹曼常数,5.67x10-8W /(m2·K4); ε是物体的辐射率: T 是物体的温度(K ); To 是物体周围的环境温度(K )。 红外测温仪电路比较复杂, 包括前置放大, 选频放大, 温度补偿, 线性化, 发射率ε (比辐射率 )调节等。目前已有一种带单片机的智能红外测温仪, 利用单片机与软件的功能, 大大简化了硬件电路, 提高了仪表的稳定性、可靠性和准确性。 红外测温仪的光学系统可以是透射式, 也可以是反射式。 反射式光学系统多采用凹面玻璃反射镜, 并在镜的表面镀金、 铝、镍或铬等对红外辐射反射率很高的金属材料。 3红外测温理论基础 3.1红外辐射(红外线、红外光) 红外线是电磁波谱中,波长0.76μm -1000μm 范围的电磁辐射,位于红外光与无线电波之间。与可见光的反射、折射、干涉、衍射和偏振等特性相同。同时具有粒子性。对人的眼睛不敏感,要用对红外敏感的探测器才能接收到。红外辐射的本质是热辐射,热辐射包括紫外光、可见光辐射,但是在0.76μm -40μm 红外辐射热效应最大。 自然界中一切温度高于绝对零度的有生命和无生命的物体,时时刻刻都在不停地辐射红外线。辐射的量主要由物体的温度和材料本身的性质决定;特别热辐射的强度及光谱成份取决于辐射体的温度。 3.2黑体辐射规律 黑体红外辐射的基本规律揭示的是黑体发射的红外热辐射随温度及波长的定量关系。黑体一种理想物体,它们在相同的温度下都发出同样的电磁波谱,而与黑体的具体成分和形状特性无关。斯特藩和玻耳兹曼通过实验和计算得出黑体辐射定律: 4 0)(T T M σ=

红外测温仪应用领域及说明

红外测温仪应用领域及说明 当遇到危险的、无法接触的、无法到达的各种环境和场合时,红外测温仪将被作为首选。任何一个无法接触到的区域如果需要温度测量的话,红外测温仪可以测量表面温度可以实现非接触式测量,红外测温仪可测量的温度范围也比较大。红外测温技术已发展到可对有热变化表面进行扫描测温,确定其温度分布图像,迅速检测出隐藏的温差。由于红外测量的本质决定了红外仪器更多的被应用于工业领域。红外温度计被普遍的用在钢铁,玻璃和塑料工业。他们也被广泛的应用于预防设施中。一、红外测温仪在钢铁工业钢铁工业使用温度计是因为产品都是处于运动状态,温度都非常高。普通的钢铁工业应用是温度是一个持续的状态熔化的钢铁开始转变成块。用同一的温度重新加热钢铁是防止它变形的关键,红外温度计被用来测量回热器的内部温度。在高温旋转轧碾机中,红外温度计被用来确认产品的温度是在旋转限度内。在冷却轧碾机,红外温度计在钢铁冷却的过程中来监控钢铁的温度。二、红外测温仪在玻璃工业在玻璃工业中,要被加热到很高的温度。红外温度计用来监测熔炉中的温度。手持式的传感器通过测量外部来探测高温点。测量溶化玻璃的温度来决定适当的熔炉口的温度。在扁平的玻璃品中,传感器在每个加工阶段都要检测温度。错误的温度或过快的温度变化会造成不平的膨胀或收缩。对于瓶子和容器产品来说,熔化的玻璃会流向保持在同一温度的前炉。红外温度计被用来探测前炉的玻璃的温度。所以它在出口的地方应该是适当的状态。在玻璃纤维制品,红外传感器被用来在加工炉中探测前炉的玻璃的温度。红外传感器在玻璃工业中另外一个用途是用于挡风玻璃制品工艺中。三、红外测温仪在塑料工业在塑料工业中,红外温度计被用来避免产品被玷污,测量动态物体和测量高温塑料。在吹制的薄膜喷出的过程中,温度测量来调整适应加热和冷却

便携式红外测温仪简介及使用指引

便携式红外测温仪简介及使用指引 一、仪器简介 1、仪器名称:雷泰ST60红外测温仪 2、仪器介绍 Raytek(雷泰)公司于2000年推出新ST系列测温仪,该系列使用方便,测温速度快,是一种应用最广泛的红外测温仪,共有ST20、ST30、ST60、ST80四种型号。新ST系列性能更高、价格更佳。 新ST系列测温范围扩展至-32~760°C,并且系列中所有型号都带有激光瞄准方式,测温精度为+1%,光学分辨率从12:1至50:1,ST60/80发射率可调,并具有最小、平均、差值显示。 3、技术数据 温度范围:-32℃—600℃ (-25—1100oF) 光学分辨率:30:1 精度:±1% 或±1℃ (±2oF), 两者中较大的为准 重复精度:±0.5% 或±1℃ (±2oF), 两者中较大的为准 反应时间:0.5秒 光谱灵敏度:8–14μm 发射率:数码可调,步长0.01 工作温度:0℃—50℃ (32℃—120oF) 相对湿度:10–90% RH 存放温度:-20℃—0℃ (-13oF—158oF) 重量/尺寸:320 克;200 x 160 x 55 毫米 电源:9V 碱性或镍镉电池(带) 激光类型:10小时-20小时

显示保持(7秒):8点环束 数据记录12点 LCD 背景:是 显示温度:℃或oF 可选 显示精度:0.1℃(0.1oF) 三角架安装标准:1/4-20 UNC 其它选件:说明书、保修卡、塑料保存箱 4、雷泰ST60红外测温仪的应用 (1)诊断和预防电系统和设备故障的工具 在电系统和设备维修检查中,红外线测温仪证明是节约资金的诊断和预防工具。Raytek(雷泰)全线长红外线测温仪的精度是读数的1-4%,而且根据型号不同可以从180英尺的远处进行测量。这些仪器重量轻,表面有粗糙防滑纹,使用方便。 (2)测量电器设备 非接触红外线测温仪可以从安全的距离测量一个物体的表面温度,使其成为电器设备维修操作中不可缺少的工具。 (3)电设备方面的应用 在如下应用中,雷泰红外测温仪可以有效防止设备故障和计划外的断电事故的发生。 ◇连接器----电连接部位会逐渐放松连接器,由于反复的加热(膨胀)和冷却(收缩)产生热量、或者表面脏物、炭沉积和腐蚀。非接触测温仪可以迅速确定表明有严重问题的温升。 ◇电动机----为了保持电动机的寿命期,检查供电连接线和电路断路器(或者保险丝)温度是否一致。 ◇电动机轴承----检查发热点,在出现的问题导致设备故障之前定期维修或者更换。 ◇电动机线圈绝缘层----通过测量电动机线圈绝缘层的温度,延长它的寿命。 ◇各相之间的测量----检查感应电动机、大型计算机和其它设备的电线和连接器各相之间的温度是否相同。 ◇变压器----空冷器件的绕组可直接用红外测温仪测量以查验过高的温度,任何热点都表明变压器绕组的损坏。

红外测温仪企业技术标准规范

有限公司企业标准 Q/HSC021-2019 88系列红外测温仪 (工作用辐射温度计) Infrared Thermometer 2019-01-30发布2019-02-28实施 发布

目录 前言········································ III 1 范围 (1) 2 规范性引用文件 (1) 3 术语及含义 (1) 4分类及命名 (1) 5 要求 (2) 6 试验方法 (3) 7 检验规则 (5) 8 标志、标签、使用说明书 (6) 9 包装、贮存、运输 (6)

前言 本标准代替了Q/HSC008-2013《88系列红外测温仪》。 本标准与Q/HSC008-2013《88系列红外测温仪》的主要技术性差异如下:---------修改了规范性引用文件; ---------修改了基本要求及性能要求; 本标准由提出并归口。 本标准起草单位: 本标准主要起草人 本标准所代替标准的历次版本发布情况为: --------- Q/HSC008-2003。 --------- Q/HSC008-2010。 --------- Q/HSC008-2013。

88系列红外测温仪(工作用辐射温度计) 1 范围 本标准规定了具有红外测温功能的仪表,常用专业术语及含义、产品分类与命名、技术要求、试验方法和检验规则,以及仪器的标志、标签、包装、运输、贮存等一些基本要求。 本标准适用于公司生产的红外测温仪(工作用辐射温度计)。 本标准不适用于医用临床温度测量仪器及设备。 2 规范性引用文件 下列文件中的条款通过的本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本标准,然而,鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本标准。 GB/T 191-2008 包装储运图示标志 GB/T 2423.1-2008 电工电子产品环境试验第2部分:试验方法试验A:低温 GB/T 2423.2-2008 电工电子产品环境试验第2部分:试验方法试验B:高温 GB/T 2423.3-2016 环境试验第2部分:试验方法试验Cab:恒定湿热试验 GB/T 2423.8-1995 电工电子产品环境试验第2部分:试验方法试验Ed:自由跌落 GB/T 2423.10-2008 电工电子产品环境试验第2部分:试验方法试验Fc和导则:振动(正弦)GB/T 6587-2012 电子测量仪器通用规范 GB/T 9969-2008 工业产品使用说明书总则 JJG 856-2015 工作用辐射温度计检定规程 3术语及含义 下列术语及定义适用于本标准: 3.1黑体 blackbody 在给定温度下,发射和吸收全部有效热辐射的理想的热辐射体(发射率为1) 3.2发射率 ,ε emissivity, ε 在给定温度下,一个物体的辐射亮度与处于相同温度下黑体的相应辐射亮度之比。 3.3[空腔]黑体辐射源blackbody radiation source 用于检定或标准辐射温度计、具有稳定控制的温度和明确的发射率,且热辐射特性接近于黑体的凹形装置。 3.4【平】面辐射源 plate radiation source 用于检定或校准辐射温度计、具有稳定控制的温度和明确的发射率的平表面。 3.5 测量距离 measuring distance 辐射温度计与目标之间的距离(或距离范围)。 3.6距离系数distance ratio 目标聚焦状态下,测量距离与视场直径之比。 4分类与命名 4.1分类 按分辨力分为0.1℃;

相关文档