Abstract: We report on the measurement and analysis of the polarization

state of second harmonic signals generated by starch granules, using a four-

channel photon counting based Stokes-polarimeter. Various polarization

parameters, such as the degree of polarization (DOP), the degree of linear

polarization (DOLP), the degree of circular polarization (DOCP), and

anisotropy are extracted from the 2D second harmonic Stokes images of

starch granules. The concentric shell structure of a starch granule forms a

natural photonic crystal structure. By integration over all the solid angle, it

will allow very similar SHG quantum efficiency regardless of the angle or

the states of incident polarization. Given type I phase matching and the

concentric shell structure of a starch granule, one can easily infer the

polarization states of the input beam from the resulting SH micrograph.

?2013 Optical Society of America

OCIS codes: (180.4315) Nonlinear microscopy; (120.5410) Polarimetry; (320.0320) Ultrafast

optics; (120.0120) Instrumentation, measurement, and metrology; (160.1435) Biomaterials. References and links

1. P. J. Campagnola and L. M. Loew, “Second-harmonic imaging microscopy for visualizing biomolecular arrays in

cells, tissues and organisms,” Nat. Biotechnol. 21(11), 1356–1360 (2003).

2. W. Denk, J. H. Strickler, and W. W. Webb, “Two-photon laser scanning fluorescence microscopy,” Science

248(4951), 73–76 (1990).

3. F. Lu, W. Zheng, and Z. Huang, “Heterodyne polarization coherent anti-Stokes Raman scattering microscopy,”

Appl. Phys. Lett. 92(12), 123901 (2008).

4. S. V. Plotnikov, A. C. Millard, P. J. Campagnola, and W. A. Mohler, “Characterization of the myosin-based

source for second-harmonic generation from muscle sarcomeres,” Biophys. J. 90(2), 693–703 (2006).

5. P. J. Campagnola, “Second harmonic generation imaging microscopy: applications to diseases diagnostics,”

Anal. Chem. 83(9), 3224–3231 (2011).

6. X. Chen, O. Nadiarynkh, S. Plotnikov, and P. J. Campagnola, “Second harmonic generation microscopy for

quantitative analysis of collagen fibrillar structure,” Nat. Protoc. 7(4), 654–669 (2012).

7. R. W. Boyd, Nonlinear Optics (Academic Press, 1992).

8. S. Psilodimitrakopoulos, S. I. C. O. Santos, I. Amat-Roldan, A. K. N. Thayil, D. Artigas, and P. Loza-Alvarez,

“In vivo, pixel-resolution mapping of thick filaments’ orientation in nonfibrilar muscle using polarization-

sensitive second harmonic generation microscopy,” J. Biomed. Opt. 14(1), 014001 (2009).

9. G. Cox, N. Moreno, and J. Feijó, “Second-harmonic imaging of plant polysaccharides,” J. Biomed. Opt. 10(2),

024013 (2005).

10. A. D. Slepkov, A. Ridsdale, A. F. Pegoraro, D. J. Moffatt, and A. Stolow, “Multimodal CARS microscopy of

structured carbohydrate biopolymers,” Biomed. Opt. Express 1(5), 1347–1357 (2010).

11. Z. Y. Zhuo, C. S. Liao, C. H. Huang, J. Y. Yu, Y. Y. Tzeng, W. Lo, C. Y. Dong, H. C. Chui, Y. C. Huang, H. M.

Lai, and S. W. Chu, “Second harmonic generation imaging—a new method for unraveling molecular information of starch,” J. Struct. Biol. 171(1), 88–94 (2010).

12. S. Psilodimitrakopoulos, I. Amat-Roldan, P. Loza-Alvarez, and D. Artigas, “Estimating the helical pitch angle of

amylopectin in starch using polarization second harmonic generation microscopy,” J. Opt. 12(8), 084007 (2010).

13. S. Psilodimitrakopoulos, I. Amat-Roldan, P. Loza-Alvarez, and D. Artigas, “Effect of molecular organization on

the image histograms of polarization SHG microscopy,” Biomed. Opt. Express 3(10), 2681–2693 (2012).

14. R. L. Whistler, J. N. Bemiller, and E. F. Parschall, Starch: Chemistry and Technology (Academic Press, 1984),

pp. 183–247.

#182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013

(C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 538

15. D. J. Gallant, B. Bouchet, A. Buléon, and S. Pérez, “Physical characteristics of starch granules and susceptibility

to enzymatic degradation,” Eur. J. Clin. Nutr. 46(Suppl 2), S3–S16 (1992).

16. D. J. Gallant, B. Bouchet, and P. M. Baldwin, “Microscopy of starch: evidence of a new level of granule

organization,” Carbohydr. Polym. 32(3-4), 177–191 (1997).

17. G. T. Oostergetel and E. F. J. van Bruggen, “On the origin of a low angle spacing in starch,” Starch 41(9), 331–

335 (1989).

18. G. Mizutani, Y. Sonoda, H. Sano, M. Sakamoto, T. Takahashi, and S. Ushioda, “Detection of starch granules in a

living plant by optical second harmonic microscopy,” J. Lumin. 87-89, 824–826 (2000).

19. R. Carriles, K. E. Sheetz, E. E. Hoover, J. A. Squier, and V. Barzda, “Simultaneous multifocal, multiphoton,

photon counting microscopy,” Opt. Express 16(14), 10364–10371 (2008).

20. K. N. Anisha Thayil, E. J. Gualda, S. Psilodimitrakopoulos, I. G. Cormack, I. Amat-Roldán, M. Mathew, D.

Artigas, and P. Loza-Alvarez, “Starch-based backwards SHG for in situ MEFISTO pulse characterization in multiphoton microscopy,” J. Microsc. 230(1), 70–75 (2008).

21. M. Wang, K. M. Reiser, and A. Knoesen, “Spectral moment invariant analysis of disorder in polarization-

modulated second-harmonic-generation images obtained from collagen assemblies,” J. Opt. Soc. Am. A 24(11), 3573–3586 (2007).

22. M. R. Foreman, C. Macias Romero, and P. T?r?k, “A priori information and optimisation in polarimetry,” Opt.

Express 16(19), 15212–15227 (2008).

23. R. M. A. Azzam, “Arrangement of four photodetectors for measuring the state of polarization of light,” Opt. Lett.

10(7), 309–311 (1985).

24. P. A. Letnes, I. S. Nerb?, L. M. S. Aas, P. G. Ellingsen, and M. Kildemo, “Fast and optimal broad-band

Stokes/Mueller polarimeter design by the use of a genetic algorithm,” Opt. Express 18(22), 23095–23103 (2010).

25. C. W. Sun, C. C. Yang, and Y. W. Kiang, “Optical imaging based on time-resolved Stokes vectors in filamentous

tissues,” Appl. Opt. 42(4), 750–754 (2003).

26. V. Sankaran, Jr., J. T. Walsh, Jr., and D. J. Maitland, “Comparative study of polarized light propagation in

biologic tissues,” J. Biomed. Opt. 7(3), 300–306 (2002).

27. V. K. Valev, A. V. Silhanek, N. Smisdom, B. De Clercq, W. Gillijns, O. A. Aktsipetrov, M. Ameloot, V. V.

Moshchalkov, and T. Verbiest, “Linearly polarized second harmonic generation microscopy reveals chirality,”

Opt. Express 18(8), 8286–8293 (2010).

28. T. Verbiest, M. Kauranen, J. J. Maki, M. N. Teerenstra, A. J. Schouten, R. J. M. Nolte, and A. Persoons,

“Linearly polarized probes of surface chirality,” J. Chem. Phys. 103(18), 8296–8298 (1995).

29. N. Mazumder, J. Qiu, M. R. Foreman, C. M. Romero, C.-W. Hu, H.-R. Tsai, P. T?r?k, and F.-J. Kao,

“Polarization-resolved second harmonic generation microscopy with a four-channel Stokes-polarimeter,” Opt.

Express 20(13), 14090–14099 (2012).

30. E. Collett, Polarized Light: Fundamentals and Applications (Marcel Dekker, 1993).

31. J. G. Webster, “Polarization measurement,” in The Measurement, Instrumentation and Sensors Handbook (CRC

Press, 1998), Chap. 60.

32. J. Qiu (Modern Optics Laboratory, National Yang-Ming University, 155 Li-Nong St., Taipei 112, Taiwan) and

N. Mazumder are preparing a manuscript to be called “Stokes vector formalism based nonlinear optical

microscopy.”

33. A. Buléon, P. Colonna, V. Planchot, and S. Ball, “Starch granules: structure and biosynthesis,” Int. J. Biol.

Macromol. 23(2), 85–112 (1998).

34. T. A. Waigh, K. L. Kato, A. M. Donald, M. J. Gidley, C. J. Clarke, and C. Riekel, “Side-chain liquid-crystalline

model for starch,” Starch 52(12), 450–460 (2000).

1. Introduction

Nonlinear microscopy techniques exploiting, for example, second and third harmonic generation (SHG and THG) [1], two-photon excitation fluorescence (TPEF) [2] and coherent anti-Stokes Raman scattering (CARS) [3] are widely used in cellular and tissue imaging because they allow high molecular contrast, therefore enabling characterization of subcellular details. Much effort has been made, for example, in SHG microscopy of non-centrosymmetric biological media and structures, such as collagen and myosin [4–6], due to the strong structural dependence of SHG [1,7]. Strong SHG signals are also known to arise in plant samples, due to semi-crystalline polysaccharides, such as cellulose and starch, which are present [8,9], however detailed characterization of SHG signals originating from these bio-molecules has not yet been fully pursued. Combination of SHG and CARS microscopy has only recently, for instance, been used to investigate the internal structural and chemical information of starch granules [10]. It has, however, been demonstrated that there is a significant relationship between polarization-resolved SHG signals and the crystalline structure of different types of starch grains [11–13]. Specifically it is noted that the second #182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013 (C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 539

harmonic (SH) signal contrast is dependent on the incident polarization state, hence providing

an interesting means to probe molecular orientation and disorder [6].

Starch is a glucose polymer often found in plants in the form of grains. These grains are

water insoluble macroscopic complex networks of amylose and amylopectin [14], organized

widely studied by scanning electron microscopy of thin sections of granules [16,17], nevertheless, detailed knowledge regarding the structure, organization and arrangement of

lamellae is still limited. The crystalline layers consist of ordered regions comprising double

helical structures formed by short amylopectin branches. The amylopectin chains in the crystalline layers are strongly anisotropically aligned within the focal volume of the laser and

thus yield a strong second-order nonlinear optical response [9,18]. Importantly, it should be noted that SHG microscopy usually relies on Type I phase matching, that is hνω,ordinary + hνω, ordinary→ hν2ω, extraordinary, for the SH signal. Unlike nonlinear optical crystals, such as KDP, LBO, etc., the concentric shell (or ring) structure of starch granules implies that phase

matching is more easily satisfied. Given type I phase matching and the concentric shell

structure of a starch granule, one can easily infer the polarization states of the input beam from the resulting SH micrograph as will be seen below.

The utility of SHG microscopy for the study of starch grains is a current topic of research

interest [13,19,20]. The implementation of polarization measurements and SHG imaging of starch grains provide complimentary information about micro-domains [11]. Specifically polarization-resolved SHG microscopy can provide information about the orientation and degree of structural organization inside biological samples using the anisotropy parameter and other signal analysis methods [13,21].Since the focal volume of the microscope objective is much smaller than the granules in the focal plane, the SHG intensity in each pixel depends on the net orientation of the electric dipoles within the illumination focal spot and the input polarization of the laser beam. We have developed a four-channel Stokes-polarimeter based on a pixel by pixel image analysis, capable of characterizing the polarization response of starch spatially. The polarization state of the SHG signal after interaction of the light with the amylopectin is characterized by the Stokes parameters, which can be inferred from the measured intensities in each polarimeter channel. Stokes polarimetry requires combination of a polarization state generator (PSG), a sample and a polarization state analyzer (PSA) to deduce the Stokes parameters [22–24]. Most Stokes polarimetry studies have focused on using linear optical process on a sample and measuring the degree of polarization of the light in transmission mode [25,26].

It is reported that chirality can be detected by linearly polarized light generated via a

second harmonic or sum-frequency generation process and may arise entirely in the electric-dipole approximation [27,28]. SHG efficiency from chiral molecules has a strong dependence upon the handedness circularly polarized excitation beam.

In this work, we describe the application of a four-channel photon counting based Stokes polarimetric and SHG imaging technique to determine the complete polarization state of SH light and to differentiate macroscopic structures of starch granules. By varying the incident polarization and detecting the SH signal originating from a single plane, a differential measurement can be made. Again, we observed that signals from starch granules reflect the polarization states of the incident excitation beams due to their concentric shell like structure. We also report on characterization of the polarization properties of the molecular structure of starch, by deriving various polarization parameters from the measured Stokes vectors, such as the degree of linear and circular polarization.

#182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013 (C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 540

2. Materials and methods

2.1 Polarization imaging system

The experimental arrangement of our SHG imaging system, used to measure the polarization states of the SHG signal, is described in detail in [29]. A femtosecond Ti:Sapphire (Coherent Mira Optima 900-F) laser oscillator, with central wavelength of 800 nm, a full width at half maximum (FWHM) spectral width of 15 nm pulses with duration of ~100 fs, average power ~550 mW, and repetition rate ~76 MHz, was used as the excitation light source. Samples were mounted upside-down on an XYZ stage and scanned with a laser scanning unit (Olympus, FV300). The measured signals were analyzed by means of a polarization state analyzer (PSA), specifically, a four-channel Stokes-polarimeter (see Fig. 1). In the four-channel Stokes-polarimeter imaging configuration, an objective lens (UPlanFLN40X/N.A. 1.3 oil, Olympus Corp., Japan) and a long-working distance 0.5 N.A. condenser provide excitation and SHG signal collection, respectively. A band pass filter of 400 ± 40 nm (Edmund Optics Inc. Barrington, New Jersey) was also inserted into the SHG emission path. The central SHG wavelength was verified using a fiber optic spectrometer (QE 65000, Ocean Optics) to be 400 nm. Stokes images, denoted ‘S out’, were determined from four distinct polarization resolved SH intensity images, measured using a 256 × 256 pixel array, corresponding to 50 × 50 μm scanning area, by means of the algorithm detailed in Section 2.2. A pixel dwell time of 8μs was used and the light was collected by PMTs through standard multimode fibers (FT1500EMT, 1.5 mm core diameter, 0.39 N.A., Thorlabs).

Fig. 1. Schematic diagram of our polarization-resolved SHG microscope with four-channel

Stokes-polarimeter module. IX81: The Olympus inverted optical microscope, HWP: Half

wave-plate, QWP: Quarter wave-plate, S: Sample, BS: beam splitter, FR: Fresnel Rhomb, WP:

Wollaston Prism, Ia, Ib, Ic, Id: photo-multiplier tubes (PMTs). TCSPC: Time Correlated Single

Photon Counter.

The PMTs were connected to time-correlated single photon counting (TCSPC) electronics for improving sensitivity and signal-to-noise ratio. The measured intensity signals were relayed through a four-channel router (PHR800, PicoQuant GmbH, Berlin, Germany). Data collection and primary analysis was performed using a commercial software package (SymPhoTime, PicoQuant GmbH, Berlin, Germany).

#182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013 (C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 541

2.2 Image processing and algorithms

Stokes parameters, denoted [S0, S1, S2, S3], give a convenient and complete description of the polarization state of light, and were thus used to characterize the polarization state of detected SH signals. Physically, S0 represents the total intensity of the emitted signal, S1 is the intensity difference in the intensities between horizontal and vertical linear polarization states at 0° and 90°, S2 is the intensity difference between linear polarization states at 45° and ?45°, and S3 is the difference in intensities between right (RCP) and left-handed (LCP) circular polarization states, respectively [30]. To determine the Stokes parameters, S out = [S0, S1, S2, S3], of the SH signal, the measured intensity images were analyzed on a pixel by pixel basis. Specifically, the four SHG signal intensities detected by corresponding pixels in the TCSPC electronics of each measurement arm of the Stokes-polarimeter, were first stacked to form a vector I = [I a I b I c I d]t (counts per msec). Importantly, the intensity vector, I, can be expressed as the product of a 4 × 4 instrument matrix ‘A4x4’ describing the Stokes-polarimeter and the 4 × 1 Stokes vector, S out, of the SH signal, i.e. I = A4 × 4S out. Accordingly, the output Stokes vector S out was therefore determined using the inverse relationship S out = (A4 × 4)?1I. This equation highlights the importance of the instrument matrix with regards to correct sample analysis.

Using the Stokes parameters, further physically important parameters, such as the degree of polarization (DOP), the degree of linear polarization (DOLP), the degree of circular polarization (DOCP) and anisotropy (r) of the SH signal at each pixel of the scanning area can also calculated [29,31]. In this regard, we have developed a series of specialized routines in MATLAB (MathWorks, R2009b) to automate reconstruction of the 2D intensity images, the corresponding Stokes vector and related parameter distributions, from the acquired TCSPC data.

2.3 Sample preparation

The different polarization properties of SHG signals were obtained from starch granules using our Stokes-polarimeter setup. By varying the polarization states of the incident beam and detecting the change of different polarization components of the SH signal after the sample, we reconstructed 2D SHG Stokes images of starch granules. The polarization-resolved SH images were obtained from potato starch suspended in aqueous solution. The starch granules were extracted from home-grown potatoes by suspending freshly-cut pieces in tap-water at room-temperature for one hour. The starch grains rapidly settle to the bottom of the beaker and were transferred to a sample vial using a pipette, and subsequently washed, several times, in clean tap water. A drop of a dilute starch-water suspension was then placed on a coverslip and the water allowed to evaporate in a flow-hood [10]. The starch grain samples then adhered to the coverslip, were re-wetted with the surrounding medium and covered with a further coverslip. The samples were mounted upside-down in the microscope stage.

2.4 Calibration

The Stokes vector of SH signals from a sample can be determined accurately if the instrument matrix ‘A4x4’ of the polarimeter is known. In reality, the instrument matrix is however determined by system calibration, by inputting a set of known input polarization states into the polarimeter and measuring the output intensities. To avoid dispersion effects in the polarimeter, we inserted a polarization state generator (PSG) after the sample stage, comprised of KDP micro-crystals (SIGMA, Germany) sandwiched between two cover glass slips and immersed in oil, for optimal index matching. By focusing the 800 nm pump laser onto the KDP sample, a 400 nm SHG signal is produced. The generated SH light is collimated by the condenser lens operating in transmission mode and relayed to the PSG, as described in the Materials and Methods of our previous work [29], to generate 0°, 90°, 45° and RC polarization states. The PSG is removed once the polarimeter is calibrated. Figure 2 shows the normalized Stokes parameters of the SH beams, after the PSG, that were input into the #182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013 (C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 542

polarimeter. S0 is normalized to its maximum value and S1, S2, S3 are normalized to S0 in a pixel-wise manner. It is evident from Fig. 2 that the values of the Stokes parameters of the given polarization state are close to the theoretical values.

Fig. 2. Shows the reconstructed 2D Stokes images for input polarization states correspond to

0°, 45°, 90° linear, and RC polarization, respectively. The color scale shows the values of each

parameter increasing from blue to red. The theoretical values of S0, S1/S0, S2/S0 and S3/S0 at 0°,

45°, 90°, RCP are [1 1 0 0], [1 0 1 0], [1 ?1 0 0] and [1 0 0 1], respectively.

We optimized our four-channel Stokes-polarimeter for operation at 400 nm, by minimizing the condition number of the instrument matrix (A4x4)?1, implying that propagation of errors from the measured intensities to the determined Stokes parameters was minimal [22]. In this work, we typically tuned the PSA to achieve a condition number of the instrument matrix of 3.0. The performance and accuracy of the four-channel Stokes-polarimeter are discussed in detail in [32].

3. Results and discussion

3.1 Illumination dependence of the SHG intensity from starch

It is known that SHG signal strength depends on the geometrical characteristics and the relative path differences between SHG active molecules within the sample [33]. To investigate this phenomenon further, we acquired a large variety of SH intensity patterns, by varying the polarization state of the incident laser light and detecting different polarization components of the SH signal via our PSA. Figure 3(a) and Fig. 3(b) show, for example, the reconstructed 2D Stokes images derived from SH signals originating from starch granules when illuminated with horizontally and vertically polarized light respectively. From the Stokes parameters, it is evident that an excitation pulse of linearly polarized light (which can equivalently be considered as an equal superposition of right and left circular polarized light) is transformed into right or left elliptically polarized light. The effect of different input polarization states is thus evident from the 2D reconstructed Stokes images of SH signal. Polarization light microscopy has been used to show that starch granules exhibit positive birefringence and theoretically it is predicted that crystallinity in starch granules is aligned in a radial direction [16,34]. Although, optical methods using birefringence and interference have been used to determine the macromolecular orientation in starch, to date a full determination of the polarization state of the output signals has not been reported. We demonstrate here that this output polarization directly reflects the molecular symmetry of starch granules.

#182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013 (C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 543

Fig. 3. Experimental reconstructed 2D Stokes images of the SHG response from starch

granules for (a) horizontally, (b) vertically, (c) right and (d) left circularly polarized

illumination, respectively. White arrows in the leftmost images indicate the direction of

polarization. The color scale shows the value of each Stokes parameter increasing from blue to

red. A schematic model of a starch granule is shown in (f).

As shown in Fig. 3(a) and Fig. 3(b), the SHG intensity images (S0) of the same sample area and depth exhibit a two-lobe structure, oriented parallel to the linearly excited polarization directions. For a fixed linear laser excitation polarization, the SHG intensity is a function of cos2θ, where θ is the angle between the state of (linear) polarization and the net orientation of dipoles within the excitation region [6]. For example, the SHG intensity is minima when the laser polarization and SHG radiating dipoles are orthogonally oriented [4]. Accordingly the two lobe structure can be attributed to the radial arrangement of the SHG active crystals i.e. amylopectin in the starch granules. Therefore, it is also seen that lobe orientation in the S0intensity distribution mirrors the polarization state of the input beam. From the reconstructed 2D Stokes images, it is also observed that orthogonally polarized illuminations can generate different polarization states from different positions within a single starch granule. This is a consequence of chirality and anisotropy of the starch granules.

Figure 3(c) and Fig. 3(d) show the SHG images obtained from the same area as those shown in Fig. 3(a) and Fig. 3(b), albeit using a right and left circularly polarized illumination, respectively. Figure 3(c) and Fig. 3(d) demonstrate that circularly polarized light can excite all amylopectin molecules in the starch granules. Right and left circularly polarized light, however, is scattered by amylopectin molecules differently and is transformed into left or right elliptically polarized light depending on the handedness and absolute orientation of the amylopectin molecules. This behavior is particularly evident when considering the degree of circular polarization, as is discussed in the next section. Finally, it is worth noting that the hilum located at the centre of the starch granule (see Fig. 3(f)), is a centrosymmetric structure, #182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013 (C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 544

and thus gives rise to a dark spot in the Stokes images, when excited with both linearly and circularly polarized light. At other positions in the starch granule, however, differences in the polarization states of the SHG signals are clearly distinguishable, upon excitation with differently polarized illuminations.

3.2 Polarization properties of SHG signal from starch granule

As shown in the previous section, the SH yield from amylopectin molecules in starch granules has a strong polarization dependence (see also [12,20]). The unique advantage of SHG microscopy in combination with a four-channel Stokes-polarimeter, is the capability to extract the complete polarization state of the SH signal, from which additional molecular orientation information can be obtained, via further processing of the obtained Stokes parameters. Second-order effects are, in particular, very sensitive to the structural symmetry of the samples; such that the anisotropic and concentric shell structure of starch granules gives rise to a unique polarization dependent behavior of the SH signal. Figure 4, for instance, shows the spatial variation in the DOP, DOLP, DOCP and anisotropy, r, as was derived from SHG light obtained from starch granules upon illumination with different polarization states. Since these polarization parameters are related to the alignment of dipoles within the focal volume, Fig. 4 highlights the different morphologies of the crystallites present within a starch granule. These polarization-resolved SHG images were obtained without relying on any sample alignment or analyzer rotation before the detector.

As shown in Fig. 4, the DOP of the SH signal from starch is approximately unity, indicating that the SH signal from starch granules is predominantly fully polarized regardless of the illuminating polarization state. Physically, this fact demonstrates that the crystalline layer of amylopectin branches is well ordered. The DOLP distributions shown in Figs. 4(a) and 4(b), furthermore, depict the degree of crystalline alignment of molecules parallel in the horizontal and vertical directions respectively. The DOLP values for both horizontally and vertically polarized excitation is seen to peak at approximately unity and to vary sinusoidally with angle, again indicating a good radial alignment of the crystallites in the starch granules. Linearly polarized light interacting with the amylopectin molecules will, however, also undergo optical rotation by virtue of circular birefringence of the starch granules.

#182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013 (C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 545

Fig. 4. Experimental polarization-resolved 2D reconstructed DOP, DOLP, DOCP and

polarization anisotropy images of SHG response from starch granule for the; (a) horizontal, (b)

vertical, (c) right and (d) left circularly polarized polarization respectively. The direction of

polarization is indicated by a white arrow in the images. The color scale shows the values of

each parameter increases from blue to red.

Similarly to above, Fig. 4(c) and Fig. 4(d), consider excitation with circularly polarized light. The corresponding DOP images show more homogeneity than for linearly polarized illumination, whilst the DOLP varied from 1 to 0. It should be noted that the strong SH signal arises because the fraction of different handed amylopectin molecules is unequal, in turn producing a non-centrosymmetric structure [29].The degree of circular birefringence of the SH signal is therefore expected to give information on the distribution of specific amylopectin molecules.

Ellipticity of the SH signal can, however, be quantified by the DOCP, defined as the fraction of the difference in intensities in left and right circularly polarized states to the total intensity. For linearly polarized excitation, the DOCP values varied in different regions as shown in Fig. 4. For horizontal and vertically polarized illumination, the DOCP is zero along the direction of excitation polarization, whereas the DOLP value is approximately 1 from the same regions. We note that the higher the value of DOLP, the lower the value of DOCP is, i.e. molecules are more arranged in a radial direction. The reverse relationship between the DOLP and the DOCP is seen when the starch granule is illuminated with circularly polarized light (Figs. 4(c) and 4(d)).The DOLP and DOCP distributions hence demonstrate that there exists components of both linearly and circularly polarized light in the SH signal. In particular, birefringence of starch granules gives rise to a variation of the relative phase between field #182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013 (C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 546

components [33] with position, which hence transforms an incoming polarized state. Depending on the sample depth, the resulting polarization state can vary between being fully linearly to circularly polarized light. When a circularly polarized illumination is used, the SHG intensity depends strikingly on the helical structure of the amylopectin molecule. Consequently, right and left circularly polarized light produce an asymmetric behavior of the SHG signal intensities generated from starch molecules. The concentric shell like structure in starch granules is seen to affect the SH polarization, resulting in a polarization shift away from both the fundamental and SH signal produced by the sample. This shift is clearly visible in the DOCP image and the SH signal is a mixture of both linearly and circularly polarized light. In this study, with the help of Stokes parameters we have hence shown that linearly polarized can be used to detect the handedness of helical materials.

The effect of birefringence on the SHG signal was also explored via anisotropy measurements, which confirm the strong differences from different areas of starch granule. The SHG anisotropy value (r) varies between ?0.5 to 1, where r = 0 represents an arrangement of molecules (e.g. random), such that the parallel and perpendicular polarized components of the SHG intensity are equal. In contrast r = 1 corresponds to alignment of all molecular dipoles relative to the incident laser polarization. SHG polarization anisotropy furthermore provides additional information on the amylopectin distribution within a starch granule, since the SHG signal anisotropy is related to the alignment of molecular dipoles within the focal volumes [6,13]. Figure 4 shows the acquired polarization anisotropy (r) images of starch granules under differing illumination polarization states. For a horizontally polarized laser light, the anisotropy value has a minimum of approximately ?0.5. Furthermore, for a vertically polarized illumination r peaks at approximately unity. In both cases there is an angular variation, in a similar manner to the S1 images, indicating that amylopectin molecules are arranged in a radial manner. The anisotropy images thus reveal that starch granules are highly anisotropic, as would be expected based on the known pitches of distinct helices within the coil structure of amylopectin [6]. This suggests that starch granules possess cylindrical symmetry.

4. Conclusion

In this work, we developed a model Stokes vector based four-channel polarimeter integrated within a SHG microscope. Stokes vector based polarization measurements were performed in the forward direction for characterization of molecular structure and orientation of starch granules in a rapid manner. This technique was shown to yield the polarization states of SHG signals, as quantified by the Stokes parameters, for a fixed input polarization state. Furthermore, starch granules were shown to exhibit polarization distributions reflecting that of the input polarization, due to the radial distribution of amylopectin molecules. The DOLP and DOCP of SH signals were calculated and analyzed, further elucidating structural properties of individual starch granules. Finally, we presented a technique to observe type I phase matching and concentric shell like structure in starch granules through four-channel Stokes polarimeter. In conclusion, starch granules were extensively analyzed to demonstrate the validity, and potential, of 2D polarization resolved SHG microscopy.

Acknowledgments

We appreciate greatly fruitful discussions with Prof. Tsu-Wei Nee regarding implantation of Stokes vector based methods. The authors would also like to thank the National Science Council, Taiwan (NSC99-2627-M-010-002, NSC98-2627-M-010-006, NSC97-2112-M-010-002-MY3, and NSC98-2112-M-010-001-MY3) for their generous support of the reported work.

#182802 - $15.00 USD Received 7 Jan 2013; revised 23 Feb 2013; accepted 23 Feb 2013; published 11 Mar 2013 (C) 2013 OSA 1 April 2013 / Vol. 4, No. 4 / BIOMEDICAL OPTICS EXPRESS 547

电气设备安全维护和管理制度范文

电气设备安全维护和管理制度 1、应按规定正确安装、使用电器设备,相关人员必须经必要的培训,获得相关部门核发的有效证书方可操作。各类设备均需具备法律、法规规定的有效合格证明并经维修部确认后方可投入使用。电气设备应由持证人员定期进行检查(至少每月一次)。 2、防雷、防静电设施定期检查、检测,每季度至少检查一次、每年至少检测一次并记录。 3、电器设备负荷应严格按照标准执行,接头牢固,绝缘良好,保险装置合格、正常并具备良好的接地,接地电阻应严格按照电气施工要求测试。 4、各类线路均应以套管加以隔绝,特殊情况下,亦应使用绝缘良好的铅皮或胶皮电缆线。各类电气设备及线路均应定期检修,随时排除因绝缘损坏可能引起的消防安全隐患。 5、未经批准,严禁擅自加长电线。各部门应积极配合安全小组、维修部人员检查加长电线是否仅供紧急使用、外壳是否完好、是否有维修部人员检测后投入使用。 6、电器设备、开关箱线路附近,严禁堆放易燃易爆物并定期检查、排除隐患。 7、设备用毕应切断电源。未经试验正式通电的设备,安装、维修人员离开现场时应切断电源。 沈阳市博才中学

安全用电管理制度 学校安全用电关系到学校教育教学顺利开展和师生安全大事,为确保安全用电,特制订如下制度。 一、学校经常教育师生用电安全的重要性,特别是教育学生按规定使用,不可玩弄电器设施。 二、学校电工每周定期二次对全校所有电器设备进行全面检查,并做好记载,发现问题及时处理解决,对不规范使用电器现象要给予指出并纠正。在修理和安装电器时,必须按安全规范操作。 三、总务处每月对电器、电路检查一次,发现问题及时解决,在寒暑假对全校电器、电路进行全面维护和检修,并作好情况记录。 四、班级用电安全由班主任负责,各办公室用电安全由室长负责,各专用室用电安全由管理员负责。各班级各部门在使用电器中发现不安全情况,先停止使用,再报告电工处理解决。 五、学校空调(除接电脑室、接待室外)冬天在4℃以下(包括4℃)夏天在31℃以上(包括31℃)才能开启。任何个人不得把家中的电器拿到学校来使用。各教室照明设施,晴天应关闭。 沈阳市博才中学

电气设备维护制度(最新版)

电气设备维护制度(最新版) Safety management is an important part of enterprise production management. The object is the state management and control of all people, objects and environments in production. ( 安全管理 ) 单位:______________________ 姓名:______________________ 日期:______________________ 编号:AQ-SN-0051

电气设备维护制度(最新版) 一、电力变压器如不经常过负荷,每年小修一次,十年大修一次。 二、高压开关的检修周期应根据开关存在缺陷和实际运行条件来确定。一般情况下每2、3年小修一次,5年大修一次,新投入的高压开关,一年以后进行一次大修,故障掉闸三次以上或严重喷油及喷烟时,立即停电检修。 三、高压隔离开关,负荷开关及跌落保险每年检修一次。 四、低压配电装置的检修和试验,一般情况下每年部少于两次,时间安排在雨季到来之前和冬季高峰负荷到来之前进行。 五、投切负荷用电的低压刀开关每半年检查一次触头。 六、配电盘和二次回路,应在每年春季和秋季,分别进行一次

检修和清扫。 七、整流设备蓄电池每半年检查维护一次。 八、电压、电流互感器的检修周期,应根据历年预防性试验结果,通过绝缘分析来确定,但一般随同高压设备检修同时进行。 九、绝缘工具每半年试验一次,避雷器每年试验一次。 十、配电室内的接地网每年检测一次。 XXX图文设计 本文档文字均可以自由修改

电气设备及运行管理规定

电气设备及运行管理规定 文件编号:JBKG -ZCGLZD-2014-002 编制单位: 编制部门: 修订时间:

电气设备及运行管理规定 [JBKG-ZCGLZD-2014-002] 第一章总则 第一条目的 为加强对公司电气设备及运行管理(以下简称电气管理工作),提高管理水平,保障电力系统安全、可靠、稳定、经济运行,结合公司实际,制定本规定。 第二条适用围 本规定适用于公司电力系统和电气设备的设计、安装、检修、运行、更新、报废管理。 第三条“三三二五”制 本规定所称“三图、三票、三定、五规程、五记录”(以下简称“三三二五”制),具体包括: 1.三图是指一次系统图、二次回路图、电缆走向图。 2.三票是指工作票、操作票、临时用电票。 3.三定是指定期检修、定期试验、定期清扫。 4.五规程是指检修规程、试验规程、运行规程、安全规程、事故处理规程。 5.五记录是指检修记录、试验记录、运行记录、事故记录、设备缺陷记录。 第二章职责与分工 第四条支持保障部是公司电气主管部门,主要履行以下职责 1.起草公司电气管理的规程、规章制度和细则,检查考核执行情况。 2.审核公司35KV及以上电压等级电气设备更新计划、电气设备的选型,审核电气设备、设施的封 存、停用、启用、转移及报废。 3.审核公司主要电气设备、设施大修和改造计划,审核关键设备检修及技术改造方案。 4.组织开展电气设备检查和评比,组织关键电气设备的技术分析及技术鉴定工作。 5.定期组织公司电气专业管理工作会议,对存在的问题提出改进措施并监督实施。 6.负责汇总、上报电气专业报表,汇总各单位上报的电气设备故障统计和分析。 7.推广应用新技术、新工艺、新设备、新材料,开展电气专业技术攻关。 8.按公司《事故管理规定》组织对公司级电气设备事故的原因调查、分析及处理。 第五条公司安全管理部门主要履行以下职责 1.审定公司《电力安全工作规程》、《临时用电安全管理规定》,检查、监督执行情况。 2.负责对施工现场用电作业和设施进行安全检查和监督。

电气设备部管理制度

电气设备部管理规章制度 一:部长职责 1:电气设备部长在总经理、副总经理领导下,具体负责组织实施全厂的设备管理工作。组织实施电控箱生产任务的各项工作。 2:制订、贯彻和执行有关电气设备部的管理规章制度。 3:建立设备的台帐、卡片、档案,统管全厂的设备技术资料。 4:负责设备的验收、移交、转移、封存启用、调拨、报废等工作. 5:负责设备事故的处理及对设备保养的奖惩工作。 6:编制设备的检修,一、二级保养计划和备品配件管理,并负责做好以上各项工作的实施和验收、考评工作。 7:采取勤巡检、勤考核等有效措施,提高全厂设备的完好率,巡检工作,每周一次。 8:监督生产设备的使用情况,每月组织一次设备管理会议,通报设备使用管理状况。 9:安排设备维修、保养管理工作,及时解决车间及其他部门提出的设备管理上的问题。 10:对设备科人员进行绩效考核。 11:对全公司设备的正常运转、供电正常化负责。 12:负责组织新购设备的到货验收、安装、试运行。 二:维修组长职责 1:全面负责本公司的设备管理。 2:负责本公司设备保养考核。 3:组织相关部门对设备进行检查。 4:督促部长及各成员对设备进行管理,对各部门设备维护保养进行抽查。 5:及时处理设备管理过程中出现的问题,周末及节假日,在部长的组织下,对全公司设备进行检查。 6:负责建立每台设备的验收、维护保养、修理、转移的电子档案。 三:维修人员岗位职责 1:维修人员必须服从上级领导的安排,认真做好设备维修工作。 2:维修人员必须凭“设备报修单”进行维修,“维修单”统一由操作者填写,并由车间主管签字后交到电气设备部,再统一安排给维修工实施维修。 3:值班时间内发生的设备故障,一律由值班维修工承担负责修理,并按接到

互联网招聘简历模板

三一文库(https://www.360docs.net/doc/3c8884208.html,)/简历 〔互联网招聘简历模板〕 互联网招聘简历模板是怎么样的呢?以下就是小编整理的互联网招聘简历模板,一起来看看吧! 姓名:刘先生性别:男 婚姻状况:未婚民族:汉族 户籍:广东-韶关年龄: 28 现所在地:广东-佛山身高: 168 希望地区:广东-广州、广东-佛山、广东-东莞 希望岗位:行政/人事类-人事经理/主管 行政/人事类-招聘经理/主管 寻求职位:招聘、行政人事主管、行政经理 教育经历 2004-09 ~ 2007-07 中南林业科技大学人力资源管理大专 培训经历 2011-03 ~ 2011-03 广州黄浦军校团队拓展结业 **公司(2009-09 ~ 2013-01) 公司性质:私营企业行业类别:其它生产、制造、

加工 担任职位:招聘主管岗位类别:招聘经理/主管 工作描述: 1、负责公司组织架构和定编配置管理,进行工作分析,组织编制岗位说明书; 2、根据公司发展及用人需求制定招聘计划,开拓、维护招聘渠道,组织实施招聘计划; 3、通过网络、现场招聘等方式甄选简历,对应聘者进行笔试和初步面试,安排复试及录用跟进; 4、组织实施公司内部竞聘,完善内部竞聘流程; 5、策划实施校园招聘活动,完成公司年度应届毕业生招聘储备; 6、建立健全人才储备信息库和各岗位面试题库,进行招聘效果评估,不断完善招聘管理制度及流程体系; 7、协助上级核查各单位人员定编配置情况,提出人员优化方案; 8、组织新员工入职培训及考核,跟进新员工试用期工作情况; 9、指导各下属分公司开展招聘活动,审查招聘到位率与合格率。 离职原因:离职 **公司(2008-08 ~ 2009-09) 公司性质:私营企业行业类别:电子、微电子技术、

多媒体教学触摸一体机的简单介绍和实用案例

多媒体教学触摸一体机介绍与应用案例 一、基本概述 二、功能作用 三、优势特点 四、规格参数 五、案例分析

一、概述 多媒体教学一体机将红外触控技术,智能化办公教学软件、多媒体网络通信技术、高清平板显示技术等多项技术综合于一体,整合了投影仪、电子白板、电脑(可选项)、电视、触摸功能等多种设备于一体的多功能互动教学设备,将传统的显示终端提升为功能全面的人机交互设备。通过此产品用户可以实现书写、批注、绘画、多媒体娱乐以及电脑操作,直接打开设备即可轻松演绎精彩的互动课堂。 二、功能作用 1、电视功能:ALL-FHD系统全高清解决方案,支持1920*1080 ,32位真彩色全高清显示 2、计算机功能:可在5、10、20、30米之外上网,也可以用无线键盘鼠标,无线上网 3、触摸功能:配备全球最先进的多点红外触摸屏,触摸无延迟, 回应灵敏,所有控制在荧幕表面完成,任意物体触摸, 包括手指和笔点击触摸屏, 控制所有应用程序,轻松实现手写文字、绘图、加注等功能,使用流畅的稳定可靠。 4、卡拉OK功能: 拥有KTV点唱功能,即点即唱,娱乐方便。 5、电玩功能:可以当一部电玩,直接由触摸屏代替鼠标操作魔兽,谷歌地球,w7游戏等触摸游戏。也可接入手柄、方向盘、摇杆、跳舞毯,进行赛车、射击、斗地主、魔兽世界、梦幻西游、三国演义等电子游戏。 6、会议功能:可做会议演讲、策划方案讲解、远程视屏会议,电子文档即插即用,无需投影仪、投影幕布、计算机、幻灯片展示台、DVD播放器等多余设备。 7、环保白板功能:随便写,随便画,无需笔擦,而且环保。用笔用手都可以书写,可以随便删除,也可以储存、录制。 8、投影仪功能:“触动视界”大荧幕可代替投影仪,播放大屏显示档,并且图像更加清晰。 9、导购机功能:具有导购、导示功能,给与顾客指引,方便顾客查找自己所需的产品,并带有广告宣传等附加功能 10、电子查询功能:通过运营商对各种电子档、信息的输入和编辑,顾客可以自助查询到所需要的信息,减低问询的人员成本。 11、视频监控功能:可以对监视区域的安全监控,任意调出各个区域的实况视频,进行数据分析。 12、画中画功能:可以一边看电视新闻,一边可以看连续剧,上网与电视同步,游戏与卡拉OK同步。 三、优势特点

工厂电气设备维护与管理要点分析 吴小斌

工厂电气设备维护与管理要点分析吴小斌 发表时间:2019-08-13T16:17:21.770Z 来源:《科学与技术》2019年第06期作者:吴小斌[导读] 对工厂电气设备进行研究,分析其维护与管理方法。乐利精密工业(深圳)有限公司广东深圳518103 摘要:现阶段,随着我国社会的不断发展,科技的不断进步,我国各个领域均得到了很好的发展。工厂电气设备的运行负荷非常大,增加了维护与管理的压力。随着工业的发展与推进,工厂的数量明显增加,而电气设备是工厂生产的主要途径,需采取科学的维护与管 理,才能保障其在工厂中的应用性能,避免出现性能或质量问题,降低电气设备的风险发生几率。文章通过对工厂电气设备进行研究,分析其维护与管理方法。 关键词:工厂;电气设备;维护;管理 引言 “工业化”是人类社会生产力提升到一定水平的标志,从18世纪“工业革命”到21世纪的“电气化时代”,电气设备在工厂生产环境中的应用率不断提升,已经构成了现代工业体系的基础组成部分。在劳动力逐渐由电气设备取代的情况下,人们不得不面对一个新问题,即人力“新陈代谢”转化为电气设备的“更新换代”,电气设备长期运行中普遍存在着各种故障,如过热、腐蚀、接触不良等,需要投入大量人力、物力、财力,以谋求电气设备无故障运行保障。由此,在现代工厂中加强电气设备维护、管理能力,是一个必然的需求,也是确保工厂可持续发展的重要途径。 1工厂电气设备运行过程中常出现的故障 1.1设备状态异常 工厂电气设备正常运行中会散发出一定的热量,热量在正常的范围内表示设备状态正常,但是运行中的电气设备过热,即可说明设备处于异常的状态,影响了电气设备的工作状态。设备状态持续异常,增加了电气设备的热量,容易损坏设备或所在系统,设备状态异常的主要表现是表面过热,其可通过红外诊断技术监测出来,一旦工厂电气设备过热,需及时处理此类异常现象,避免影响工厂电气系统的运营状态。 1.2工厂电气设备的接触不良 工厂电气设备的接触不良同样也是比较常见的故障之一。如某工厂在进行工厂电气设备的维护维修时,就是由于电气设备的接触不良所导致的,并且常常有四种情况会导致电气设备的接触不良。其中之一:在安装电气设备过程中,由于安装不到位,或者在连接点的时候没有连接坚固,从而使得电气设备在后期的使用过程中,出现接触不良的问题;其中之二:由于工厂电气设备在运行过程中受到冲击时,使得电气设备受到了干扰,从而影响到电气设备的正常运行,最后导致电气设备的接触不良:其中之三:工厂电气设备一直处于长期的运行状态,没有进行定期的维护与检修,从而在运行过程中有一些锈蚀或氧化的问题,同样会导致工厂电气设备的接触不良:其中之四:工厂电气设备中所使用的电子元件或者是配件,在过热的环境下会加速产品的老化,从而影响到工厂电气设备的接触。 1.3三相不平衡的问题 三相不平衡问题是电气设备运行方面的一大问题。确切的说,电气设备其驱动能源是电力,现时期电气设备结构构成主要是三相式电机,在正常情况下,三相交流电所供应的频率和振幅是相同的,并且是相位差在120°的电力,这种情况下的电力称为平衡状态,在此基础上,电阻和电流所形成的热量都是相同的,为此可以确定这时的电气设备其运行状态是平稳安全的。但是,在实际运行中,如想确保运行状态的理想化是非常困难的,相不平衡的问题是一种常见性问题,任一相出现失衡,均都会产生电阻热量超标及烧毁的情况。所以,电气设备在平时的维护与管理中,在察觉有过热、震动和噪音的情况下,需尽早做出停机操作。 2工厂电气设备维护与管理的方法 2.1工厂电气设备的日常维护 工厂电气设备的日常维护,有利于提升电气设备的运行性能,确保其在工厂电气系统内的稳定性。针对工厂电气设备的日常维护,提出两项措施,分析如下:(1)执行定期保养,日常类维护保养的周期是每周一次,如果是检修类保养,可以安排半年一次或一年一次,也可以按照工厂电气设备的季节性状态,采取季节保养的方式,定期保养中要清理电气设备的运行环境,尤其是设备内部的灰尘,完善电气设备的运行环境,进而提高电气设备在工厂中的运行质量;(2)维护电气设备中较容易出现安全隐患的地方,如连接点、电源插头等,检测电气设备中是否存在老化、破损的问题,同时做好设备润滑工作,确保各项设备的相互配合;(3)维护工厂电气设备的线路,解决三相不平衡的问题,维护人员在日常维护中,定期测量电气设备的输入电流,找出三相不平衡的原因,执行科学的维护方式,促使电气设备达到标准的工作状态,避免对工厂造成电气负担;(4)停电维护,工厂电气设备的规模不同,部分设备在日常维护中需要断电条件,将停电维护列为日常维护的一项重要内容,停电维护时要注意安全操作,同时设立警示牌,提示“禁止合闸”,一方面确保电气设备的维护环境,另一方面保障维修人员的安全性。 2.2工厂电气设备的运行管理 工厂电气设备的运行管理,主要是防护电气设备出现故障,落实预防性检修工作。围绕工厂电气设备的运行现状,提出运行管理的方法:(1)状态异常类运行管理。工厂电气设备状态异常基本是指散热异常,在电气系统内安装通风设备,加快电气设备表面空气的流通速度,针对发热比较大的设备,需采取特殊的处理方法,降低电气设备表面聚集的热量,消除状态异常引发的故障问题,防止电气设备因状态异常而发生毁坏性故障;(2)接触不良类运行管理。工厂在管理电气设备时,借助红外热成像方法,全面检测电气系统,找出接触不良的设备并处理,以免引发更大的接触事故。电气设备接触不良会增加设备本身的电阻,而红外热成像恰好可以检测到异常发热的部分,管理人员迅速诊断电气故障,实行预防性的检修,排除故障的安全隐患;(3)三相不平衡运行管理。三相不平衡运行管理集中在电机和电源两个方面,所以管理人员针对三相不平衡实施运行管理时,可以按照以下两方面的内容执行:一是电机管理,科学地安排检修与维护,必要时可直接更换电机,减轻电气设备运行的负担,避免电机烧毁,进而降低了电气设备故障的间隔时间;二是电源管理,此类问题需快速诊断、解决。 2.3维护管理人员的专业能力需不断提升

公司员工招聘简历模板

个人简历 姓名:??性 别: 民 族: 出生年月:??联 系电话: 工 作经验: 学历:??专 业: 毕 业学校: 住 址: ?? 电子 信箱: ?? 求职意向: 目标职 位: 希望应聘的岗位 页脚内容1

目标行 希望应聘的行业范围 业: 期待的工资水平福利需求,一般填面议比较稳妥期望薪 资: 期望地 希望工作的地区、城市范围 区: 新岗位能够多长时间内到任 到岗时 间: 自我评价: 进行简要描述,说明自己的专业能力、职业能力、以及社会能力等等。 写上几段话即可。 提供参考A:热情随和,活波开朗,具有进取精神和团队精神,有较强的动手能力。良好协调沟通能力,适应力强,反应快、积极、灵活,爱创新!提高自己,适应工作的需要。所以我希望找一份与自身知识结构相关的工作,如文秘,文员,助理可以有更大的空间来证明自己,发展自己! 提供参考B:具有一定的社会交往能力,具有优秀的组织和协调能力。 页脚内容2

在学习中,我注重理论与实践的结合,己具备了相当的实践操作能力,可独立进行xx、xx工作。 熟练操作计算机办公软件。很强的事业心和责任感使我能够面对任何困难和挑战。 工作经历: 20xx—至 南京百度人才资源顾问有限公司猎头顾问 今 简介:南京顶尖的猎头公司,南京百度人才公司是一家为中高端企业、跨国企业、民营企业寻找高端人才,为高端人才 寻觅合适的发展机会、高端职位协调企业与人才之间的交流沟 通。 200x— ?? 200x 简介:公司高端人才寻觅,猎头业务受理。 xx公司xx职务 200x— 200x 页脚内容3

简介:公司概述。职责概述。 教育培训: XX技能培训中心xx培训 1997.9— —2000.7 关于***方面的专业技能培训,获得了***资格证书。 20XX—— XX大学xx专业本科 20XX 系统学习了***方面的理论知识,具有***职业的工作能力。 祝你成功 页脚内容4

探究电气设备安全运行的管理和维护

探究电气设备安全运行的管理和维护 发表时间:2018-12-12T18:20:46.083Z 来源:《防护工程》2018年第23期作者:于志坤曹立军 [导读] 随着当前我国社会主义市场经济不断深化发展,我国经济水平不断提升,企业电气自动化水平逐渐得到提升和改善 中粮生化能源(肇东)有限公司黑龙江肇东 151100 摘要:随着当前我国社会主义市场经济不断深化发展,我国经济水平不断提升,企业电气自动化水平逐渐得到提升和改善,大量电气设备在不同领域得以应用,但是在其实际维护和管理上也提出更高的要求。电气设备的日常维护和管理直接对其使用寿命存在关系,其和企业的社会效益以及经济效益存在直接联系,因此应该不断学习电气设备的维护知识,通过对其不断保养和维护,保证其使用性,从本质上解决事故的出现和发展,以此来促进企业的发展和进步。 关键词:电气设备;安全运行;管理维护 引言 在我国电力系统运行规模不断扩大的趋势下,要加强对电力设备常见问题的诊断和分析,以相关的检测参数为依据和参考,采用切实有效的电力设备检修方法和技术,确保电力设备运行安全与稳定。 1电气设备在实际维护和管理中存在的问题 1.1电气设备管理问题 很多大型设备的机组运行负荷相对较大,检查工作量较大就会导致其工作量和检查修理时间以及质量之间的矛盾增加。当前很多企业对电气设备的检查人员的专业要求相对低,这就导致其缺乏有效且专业的检修手段,使得电气设备的修理质量和维护质量很难得到保障,很多企业的检修工作仅仅停留在形式上,这就导致电气设备的故障和隐患很难得到修复和排除,由于电气设备运行负荷逐渐增加,长时间超负荷运行导致设备自身出现老化。 1.2检修人员自身问题及管理问题 由于企业员工对安全意识认识不够,不能对电气设备存在的危险点进行有效的分析和控制,极有可能导致安全事故的发生,企业的安全管理和学习交流仅仅是形式,其实际应用性差,很多企业的安全管理人员对安全引导意识的认识程度不够,不能真正将安全监管作为一种职责和义务。由于多方面的原因电气设备在其实际使用过程中不能得到有效且合理的操作,且很多工作人员缺乏专业性的指导,因此对电气设备产生重大的损坏最终就会影响整个电气工程和电网的安全运行。 2电气设备安全运行的管理和维护措施 2.1利用专家系统实现对电力设备的故障诊断检修 在对电力设备常见问题的常见问题诊断和检修过程中,还可以引入普及性高、诊断效果优良的专家诊断系统,利用其可操作性、优良的诊断效果的优势,进行电力设备运行状态的故障诊断和检修。在引入专家诊断系统的电力设备故障诊断和检修工作中,可以借助于三比值、特征气体等方法,获取并分析电力设备运行实验相关数据。例如:三比值法就可以根据充油变压器内油、绝缘纸处于故障状态下产生的气体组分含量的相对浓度和温度的相互依赖关系,进行变压器电力设备的故障诊断。特征气体法应用于变压器电力设备的故障诊断之中,以变压器油中溶解气体为特征量,由油中溶解气体组分与变压器故障类别之间的关系,进行变压器电力设备的故障诊断和分析。同时,可以组建专家系统数据库,利用智能分析平台的数据库软件成立数学计算模型,进行专业而针对性的诊断、分析和检测,获取最终的诊断分析结果。 2.2确保电气设备操作的规范性 电气设备是否能够正常有效运行,和操作人员本身的操作有着较为密切的关系,所以说,在进行电气设备运行维护的过程中,还应该要构建出一套较为严格且完善的电气设备使用操作流程,确保工作人员在使用电气设备的时候是规范的,这样才能最大程度实现电气设备的运行维护。针对于这一点,相关管理人员一定要确保电气设备操作人员操作的熟练程度,借助于适当的培训教育来帮助电气设备操作人员掌握较多的操作原理和知识;其次,在使用电气设备的过程中,最好不止是一人进行操作,可以由设计人员、管理人员共同监管实施,这样就能有效减少电气设备运行使用故障的发生。最后,在操作电气设备的过程中,完成操作之后相关人员最好是要将设备整体情况以及自己整个操作过程及时记录下来,交由相关管理人员确认签字,这样就能为之后的电气设备操作奠定较为良好的理论基础。 2.3做好电气设备日常维护工作 对于电气设备而言,不仅要对其进行常规检查以及操作管理,还需要做好电气设备日常运行维护,为了确保这一项工作的质量,以较为常见的变压器以及发电机为例对其进行相关探讨。在对变压器进行运行维护的过程中,维护人员需要多方面进行检查,比如变压器的接地保护、是否做好了相应的防雷措施;变压器铁芯绝缘保护层有没有出现老化等都是日常维护过程中需要注意的问题,在日常运行维护过程中一旦出现了上述问题也需要及时对其进行有效的处理,以此来确保变压器设备运行的稳定性和安全性,同时也能避免操作人员人身安全受到威胁。另外,发电机这一电气设备也是日常生活中较为常见的设备,而在对其进行日常维护的过程中,需要及时对散热口所堆积的尘埃以及机箱之中所存在的杂物进行清除;而且在清除的过程中,最好是不要直接接触设备,这样能够减少对设备的二次污染,延缓设备的老化,同时也能确保维护人员的生命安全;此外,在对发电机进行运行维护的时候,还需要对设备上的电刷与滑环进行及时的维护处理,确保电刷能够处在滑环中心位置;另外还需要加强发电机接地保护维护工作,以此来减少发电机设备出现故障的可能性,最大程度保障电气设备运行维护质量。 2.4更新电气设备运行技术 要想有效提高电气设备故障检修质量和效率,除了上述几点之外,强化技术更新也是一项较为关键的手段,而对于这一点,首先需要对传统技术进行总结性分析,以此为基础来不断进行完善和更新,分析已有的弊端和优势;其次,则需要对已经引入的先进技术进行合理的规划设计,通过相应的技术方案来确保检修技术应用的合理性,进而也就能够进一步促进故障检修工作质量提升。此外,检修工作人员也应该不断提升自我能力以及技术知识,明确电气设备运行维护以及故障检修今后的发展方向,树立起较为良好的创新意识和能力,这样

互联网公司社招个人简历模板.doc

互联网公司社招个人简历模板 xx简历是个人求职者在互联网公司社招过程中给招聘单位发的第一份简要介绍。下面是我整理的,以供大家阅读。一姓名:黎先生性别:男婚姻状况:未婚民族:汉族户籍:广东年龄: 30现所在地:广东-广州身高: 173cm希望地区:广东-广州、广东-东莞、广东希望岗位:计算机IT类-管理/技术支持-其它相关职位寻求职位:网络工程师、网络教师待遇要求:可面议要求提供住宿最快到岗:随时到岗教育经历2006-02 ~ 2008-01 广东教育学院计算机科学与技术本科2001-09 ~ 2004-07 广东经济管理学院计算机应用大专1998-09 ~ 2001-07 增城职中计算机应用中专工作经验至今4年6月工作经验,曾在3家公司工作***公司名称 2010-03 ~至今公司性质:私营企业行业类别:通讯、电信、网络设备担任职位:网络工程师岗位类别:网络工程师工作描述:公司网络规模为700多个节点,本人担任网络工程师一职,主要负责公司的网络维护与安全策略的规划,还负责公司内部计算机的维护工作。期间曾为公司完成准入系统和网络监控系统,确保公司网络的安全。本人工作认真,责任心强,有较强的团体合作精神,有较强的判断和处理问题的能力。项目经验1、在各交换机的接口上应用安全策略,实现外来的计算机不能访问公司的网络,必须通过我们开通权限。 2、在各部门交换机所对应的网络端口上配置端口安全策略,让交换机每个接口都自动学习其所对应计算机的MAC地址,并把学习的MAC

地址个数设为1,这样外来计算机连接到网络时就会自动断开。3、会议室的网络接口经常会有外来人携带计算机连接网络,绑定MAC地址显然不方便,因此使用802.1X协议来实现限制计算机的功能。4、根据不同会议室建立不同的用户名和密码,这样可以令不同部门所用的会议室的密码不一致,保证在不同会议室使用的计算机不能随意访问其他部门的资源。5、配置镜像端口对整个网络实现监控,再利用抓包工具或监控软件对网络数据进行分析,从而排查出网络出现的问题以及监控每个部门使用网络的情况。责任描述: 1、配置端口安全策略。2、配置802.1X策略。3、根据需求规划不同的用户名和密码。 4、配置镜像端口。***公司名称 2008-06 ~至今公司性质:私营企业行业类别:互联网、电子商务担任职位:网络工程师岗位类别:工作描述:公司网络规模为200多个节点,本人担任网络工程师一职,负责公司的网络维护,主要包括:win2003各种服务器与域的管理、路由与交换协议和网络安全策略。期间曾参与公司的内部改造,如子网和VLAN划分,路由协议配置与重分发等。本人工作认真,好学上进,严格遵守公司制度,深受领导的信赖。项目经验:1、两台核心交换机之间使用以太网通道技术,Vlan间的路由通过三层交换机实现。2、总公司和分公司使用OSPF路由协议,总公司在Area 0,广州分公司在Area 1,上海分公司在area2。3、遂达外贸公司仅在北京总公司申请一条宽带接入互联网,出口部署防火墙,并在路由器与交换机上配置安全协议。4、根据要求将使用ACL控制列表,限制总公司工作人员使用网络资源。根据VLAN划分不同子网,并在核心

现代应届生Word简历模板

证 书 校园经历 自我评价 性 名: 张三 年 龄 : 22 邮 箱 : xxxx@https://www.360docs.net/doc/3c8884208.html, 实习经验: 6个月 电 话 : 135xxxx9999 现住城市: 北京市朝阳区 求职意向 从事职业:市场推广专员 期望月薪:6K-7K 教育背景 北京某大学 2013.09-2017.06 市场营销(本科) 普通话一级甲等 大学英语四/六级 全国计算机二级考试 熟练运用OFFICE 办公软件 实习经历 公司名称:北京某信息科技有限公司 职位名称:推广经理助理 在职时间:2017.01-至今 工作描述: 工作经验的时间采取倒叙形式, 最近经历写在前面;工作经验的描述与目标岗位的招聘要求尽量匹配, 用词精准; 工作成果尽量以数据来呈现,突出个人成果以及做出的贡献;描述尽量具体简洁。如: 1 . 负责执行产品线上推广和数据整理分析,目标实现新用户增长并分析推广策略结果;通过与X 个第三方广告渠道沟通需求并跟进上线,参与XX 次推广活动策划,日常维护XX 家渠道,分析并制作每日的数据报告,实习期所在团队取得XX%用户数量涨幅 ,新增XX 新用户; 2.参与推广公司孵化的XX 新产品,包括前期需求搜集与后期验收、宣讲培训工作。前期通过组织用户与竞品调研,输出XX 份反馈结论和竞品市场分析报告,有X 项已立项并通过产品部的评审。通过参与此项目,共协调XX 个部门,推进XX 人参与其中,显著提高沟通能力。 校园职务:XX 协会主席/学生会XX 部长 在职时间:2016.09-2017.01 职位描述: 编写指南:1 .内容清晰,结果导向;2 .与目标申请岗位相结合,升华内容;3 .可参考STAR 法则来写:SITUA - TION :背景与简介?TASK :目标任务?ACTION :亮点挑战与解决办法?RESULT :成果与收益? 1. 帮助某人才招聘企业实现实习生招聘、人才引进项目; 2. 作为XX 协会主席,先后联系XX 家人才招聘企业,筹备立项及计划书,获得某公司认可支持。先后组织XX 名协会成员与其它协会团队,帮助某公司完成在XX 家高校的“XX人才计划”,向全球顶尖的XX 公司推送实习生XX 名,并获得校企共同奖励; 3. 本次经历极大锻炼了本人做事的耐心与韧性,以及锻炼带领团队的协作能力。在运营前期找了XX 家企业均被拒绝,仍坚持执行, 最终获得零突破。在协调校方资源支持下, 经过与企业XX 次的评审与演练, 筹备线上线下宣传活动, 并进行咨询人员培训与管理制度编写等工作,最终保证整个项目顺利完成。 篇幅不要太长控制在300字以内,做到突出自身符合目标岗位要求的卖点以及学校的经历亮点,多体现实习实践经验,避免 过多使用形容词,而通过数据及实例对自身价值进行深化,如:211院校营销专业学科背景,获得XX 次奖学金,创立XX 协 会,组织X 场XX 会议,系统学习了营销的定性与定量研究方法。具有X 次市场相关的实习经历,累计实践工作经验X 月,掌 握基本推广、需求搜集和数据分析等技术,执行力强,可有效评估XX 需求并组织用户研究,结合决策进行项目资源协调、 落地实施、灵活调整和复盘总结工作。

电气设备的维护与保养

电气设备的维护与保养 培训资料

一、概念 1、什么是设备巡检 设备巡检是按设备的部位、内容进行的粗略巡视,为了“观察”系统的正常运行状态,这种方法实际上是一种不定量的运行管理,对分散布置的设备比较合适。 2、什么是设备点检 为了维持生产设备的原有性能,通过人的五感(视、听、嗅、味、触)或简单的工具、仪器,按照预先设定的周期和方法,对设备上的规定部位(点)进行有无异常的预防性周密检查的过程,以使设备的隐患和缺陷能够得到早期的发现,早期预防,早期处理,这样的设备检查称为点检。 3、设备日常巡检与设备定期点检的区别与联系: (1)设备巡检员是专职人员,主要负责某个生产工艺段的设备巡检。他不同于维护人员、检修人员,也不同于维护技术人员,是经过特殊训练的专门人员。设备巡检员是利用人的五官或简单的仪器工具,对设备进行日常巡查,在巡检过程中对照标准发现设备的异常现象和隐患,掌握设备故障的初期信息,为点检人员提供要检查设备故障点、部位、项目和内容,使点检人员有目的、有方向的进行设备点检。(2)设备定期点检主要是指设备维修人员,主要负责设备故障的修复,保证生产设备的正常运行,根据设备巡检人员提供的信息,对有故障的设备进行详细地检查和修复。在有些单位也叫保全工,

(3)设备日常巡检和设备日常点检其实是一个岗位,主要负责巡查设备是否正常运行,检查设备有无异常现象,为维修提供更好的依据,缩短维修时间,尽快恢复设备正常运行。 二、设备点检的分类 按作业时间间隔和作业内容的不同,点检分为:日常点检、定期点检二类。 1.日常点检 作业周期在一个月以内的点检为日常点检或称日常检查。日常点检的对象为在用的主要生产设备,由设备操作人员根据规定的标准,以感官为主借助便携式仪器,每日一次或数次对设备的关键部位进行技术状态检查和监视,了解设备在运行中的声音、动作、振动、温度、压力等是否正常,并对设备进行必要的简单维护和调整,检查结果记入日常点检卡中。日常点检的目的是及时发现设备异常,防患于未然,保证设备正常运转。 日常点检的作业内容比较简单,作业时间也较短,一般可在设备运行中进行,所以对生产影响不大。 2.定期点检 作业周期在一个月以上的点检为定期点检或称计划点检。定期点检由设备维修人员和专业检查人员根据点检卡的要求,凭感官和专用检测工具,定期对设备的技术状态进行全面检查和测定。除包括日常点检的工作内容外,其检查作业主要是测定设备的劣化程度、精度和功能参数,查明设备异常的原因,记录下次检修时应消除的缺陷。定期点

大学应届生个人简历模板

三一文库(https://www.360docs.net/doc/3c8884208.html,)/个人简历 大学应届生个人简历模板 基本信息 姓名:张同学 所修专业:工商管理 出生日期:1986-9-1 毕业院校:XXX 民族:汉 学历:本科 籍贯:河南 毕业日期:20XX年6月 户口所在:河南 职业概况/求职意向 职位类型:全职期望职位: 期望月薪:面议期望地点:江苏、山东 教育经历 20XX年9月至20XX年6月中原工学院工商管理本科 自我鉴定 我做为农村走出来的大学生身上带着农村孩子所拥有的淳

朴气息,使我在学习和生活过程待人真诚,诚实守信,能够吃苦,充满热情尝试,踏踏实实地做好每一件对于我来说重要的事。 大学四年的生活给我了足够了磨练,诚实守信,但不愚钝,有很好的写作功底,高中的时候,曾在学校的刊物中发表过数篇文章,大学虽然时间比较紧张,但是仍坚持阅读文章、坚持写作。拥有很强的人际关系处理能力,有团队合作精神,有自己的人际关系处理方法,在处理人际关系上能够很好的把握分寸,因此在四年的大学生活中拥有很多的朋友。 热爱运动,酷爱篮球,较高的个头使得自己有不错的篮球技术,篮球作为一项激烈的运动,不但赋予了我良好的身体素质,能够承担较重的工作量,而且在球赛中增强了自己的心理素,能够正视失败,有着永不言败的性格。 热爱文艺。酷爱歌唱,从小到大,学校的文艺晚会上,经常有我的歌声,音乐不但带给了大家视听的享受,也让大家更加喜欢我、认可我,使得自己有了更好的人际关系。曾在大学阶段自创家教班,同四名同学一起教授15名中小学生,做为家教班的创立者在管理上得到很大锻炼的同时也在一定的时期内解决了 做为农村孩子在经济上的窘困局面。 语言水平 英语熟悉级别:四级普通话精通河南话精通 电脑水平 掌握办公自动化,熟练操作Word、Excel、PowerPoint、

交互式触摸一体机参数

交互式触摸一体机参数 触派电子;一切只为让触摸一体机市场更透明,“技术透明”、“成本透明”、“服务透明”、打造标准,从触派开始,优胜劣汰由大众抉择。 交互式触摸一体机合自助服务终端,以其专业的模块化结构,强大的功能扩展性(加装磁卡/IC卡读卡器、票据打印机等配件,符合特殊行业的要求)和人性化设计,满足多个行业需求。该产品已广泛应用于政府、商业、邮局、银行、商场、交通、电信、教育、旅游、宾馆、机场、展厅等行业。 连接排队机的营业员的呼叫器。主要是为了银行营业员能第一时间安排工作,此呼叫器也是触摸查询一体机的一套设备,软件会自动对排队的数字进行分析叫号。连接触摸查询一体机的窗口工业液晶显示系统。工业液晶显示系统主要对排队信息进行显示,同时提供大家IPTV 服务或视频服务,播放一下便民视频或公益广告,有利于提升银行的贴心服务,同时也让民众在排队的时间里可以从视频内容获取更好

的信息和视觉享受。 当然在我们普遍选取的时候,会面临太多不可控问题,例如触摸一体机内部采用的配件,防水密封性,延保服务,在一样可靠的牌子情况下、价太高可以忽略。 但是特别低的你就当心了,当然这个低是参考平均标准的哦,很多无良的拿二手配件翻新给你,根本查不到,用起来感觉是一样的,但是触摸屏一体机核心在使用寿命上,比如一般触摸屏点击六千万次(当然这是触派电子产的才有这么高)而你500万次就挂了,这里需要注意,在所有配件相同的情况触摸寿命很关键,所以选择些科技能力强,有些知名度的。 交互式触摸一体机利用这种技术,只要用手指轻轻地指碰计算机显示屏上的图符或文字就能实现对主机操作,从而使人机交互更为直截了当。这种技术极大方便了那些不懂电脑操作的用户。多媒体触控一体机的应用范围非常广阔,主要有公共信息的查询,如电信局、税务局、银行、电力等部门的业务查询;城市街头的信息查询;此外还可广泛应用于办公、工业控制、军事指挥、电子游戏、点歌点菜、多媒体教学、房地产预售等。将来,触控一体机还要走入家庭。 当然有些特殊用途的一体机包括的设备就更多啦,如银行用于自动取款的触摸一体机还包括键盘、磁卡刷卡器、存折补登器、微型打印机、

电气设备维护和保养

电气设备维修与维护 生产设备可以说是工业发展的基础,是企业的生存的基点,无论是结较复杂先进的数控加工设备还是功能单一结构简略的砂轮机,要想更好的利用手中的工具发挥设备的高效益,就必须正确的操作和精心的维护,才能物尽其才的服务于企业。正确的操作使用能够防止机床非正常磨损,避免突发故障;做好日常维护保养,可使设备保持良好的技术状态,延缓劣化进程,及时发现和消灭故障隐患,从而保证安全运行。维修方法的得当则能减少时间、提高效率,减少不必要的损失。然而在众多的维修技术人员中,对于维修方法更是仁者见仁智者见智,终归不外乎望、闻、问、切、测、断、短、换。 1 望,维修技术人员进入现场首先就是要看,查看各操作元件位臵正确与否,电控装臵有无报警指示,有无保险烧煅,元器件有无明显裂痕缺损、电线电缆是否脱落等等。这对于肉眼能观察到的浅显故障非常有效。 2 闻,有经验的维修人员都会知道设备电路或电器一旦有故障发生不论是短路、过载、接地错误、导线虚连松动、触点接触不良、虚焊、假焊、熔断器熔断等都会伴随发热导致绝缘材料刺激性气味的散发,如果我们迅速找到这些味道来源,那么我们就算是直接到达案发现场,给我们节省不少时间,维修起来就更有针对性。 3 问,作为维修人员来说我们不是案发现场的目击者,操作人员才是,当我们望与闻都不奏效的情况下就要把我们的目击人员询问一番了,根据他们的陈述可以了解设备与正常运行时的异常之处,帮助我们缩

小查找范围。 4 切,所谓的切就象老中医给病人号脉一样,在询问完之后我们也可以给这些铁疙瘩号一号脉,用手摸一摸设备电器元件的温度,也许你就能突然发现某个元件不正常发热。 5 测,即是测电压、测电阻;利用前面所说的方法可以带我们直接到达事故中心地带,接下来的事就可以要用测的了,测量各点的电压值与电流值并与正常值比较,测量电阻判断是否有断路或断路发生。 6 断,多支路并联且控制较复杂的电路短路或接地时,一般有明显的外部表现,如冒烟、有火花等。电动机内部或带有护罩的电路短路、接地时,除熔断器熔断外,不易发现其他外部现象。这种情况可采用逐步将这部分负荷断开检查。可重新更换熔体,把多支路交联电路,一路一路逐步或重点地从电路中断开,然后通电试验,这种方法简单,但容易把损坏不严重的电器元件彻底烧毁。 7 短,设备电路或电器的故障大多为短路、过载、断路、接地、接线错误等。包括导线断路、虚连、松动、触点接触不良、虚焊、假焊、熔断器熔断等。对这类故障除用电阻法、电压法检查外,还有一种更为简单可靠的方法,就是短接法。方法是用一根良好绝缘的导线,将所怀疑的断路部位短路接起来,如短接到某一个节点后,电路工作恢复正常,说明该处断路。具体操作可分为局部短接法和长短接法。 8 换,换是绝大数维修技术人员所采用的方法了,当我们怀疑某个元器件失效而这个元件内部结构比较复杂甚至是集成电路板的时候,我们又没有专用检测装臵,这个时候拿一个备用元件替代是最直接的。

发电厂电气设备安全运行的管理和维护

编号:AQ-Lw-08044 ( 安全论文) 单位:_____________________ 审批:_____________________ 日期:_____________________ WORD文档/ A4打印/ 可编辑 发电厂电气设备安全运行的管 理和维护 Management and maintenance of safe operation of electrical equipment in power plant

发电厂电气设备安全运行的管理和 维护 备注:加强安全教育培训,是确保企业生产安全的重要举措,也是培育安全生产文化之路。安全事故的发生, 除了员工安全意识淡薄是其根源外,还有一个重要的原因是员工的自觉安全行为规范缺失、自我防范能力不强。 摘要:近年来,我国电力行业的稳健发展对于推动我国经济社会发展起到了举足轻重的作用,特别是人们追求更高生活质量的同时,电力行业面临的挑战也越来越大,发电厂的电气设备也在不断更新、增加,这在大大提高电力行业发展的同时,也给电气设备的安全运行的管理和维护带来了一些问题。本文主要对发电厂电气设备安全运行的管理和维护进行初步的探讨分析,仅供相关人士参考。 关键词:发电厂;电气设备;安全运行;管理;维护 随着我国电力行业发展的加快,加强电气设备的创新和与时俱进是推动经济社会发展和满足人们的正常生产生活需要的必经之路,电气设备的管理与维护是保证电厂正常运转的重要部分,也是提高电厂经济效益的支撑,因此,发电厂必须要切实认识到电气设

备管理维护中存在的问题,并且采取有效的有针对性的措施将问题予以解决。 一、加强发电厂电气设备安全运行管理维护的意义 一方面,发电厂的电气设备数量众多,各个设备的结构复杂,同时,一些设备在运行过程中容易出现故障、新采购电气设备的安装和验收等等工作是确保电气设备性能稳定和工作状态正常的重要基础,也是保证稳定发电、正常发电的前提;另一方面,我国经济社会的发展、工业的全速推进,可以说跟电离不开,同时电力行业的也是我国国民经济收入的一个重要增长点,对各行各业影响非常巨大。因此,发电厂必须要加强电气设备安全运行管理与维护工作,确保电气设备运行中的稳定、可靠,从而使得电气设备处于最佳的工作状态,保证整个发电过程的安全与稳定具有十分重要的意义。 二、我国发电厂电气设备安全运行中管理和维护工作存在的问题 (一)电厂的设备管理体系不健全,管理层对电气设备安全运行管理和维护工作缺乏重视。

相关文档
最新文档