Differential pulse anodic stripping voltammetric determination of Pb ion

Differential pulse anodic stripping voltammetric determination of Pb ion
Differential pulse anodic stripping voltammetric determination of Pb ion

Differential pulse anodic stripping voltammetric determination of Pb ion at a montmorillonites/polyaniline nanocomposite modi?ed glassy carbon

electrode

YongPing Dong a ,?,Yong Ding a ,Ying Zhou a ,Jun Chen a ,?,ChengMing Wang b

a School of Chemistry and Chemical Engineering,Anhui University of Technology,Maanshan 243002,China

b

Hefei National Laboratory for Physical Science at the Microscale,University of Science and Technology of China,Hefei 230026,China

a r t i c l e i n f o Article history:

Received 13November 2013

Received in revised form 31December 2013Accepted 10January 2014

Available online 5February 2014Keywords:

Montmorillonites Polyaniline

Modi?ed electrode

Differential pulse anodic stripping voltammetry Pb 2+

a b s t r a c t

In this paper,Na +–montmorillonites/polyaniline nanocomposite modi?ed glassy carbon electrode (PANI/MMT/GCE)was prepared and characterized by scanning electron microscopy and electrochemical tech-niques.It was found that when PANI/MMT ?lm was modi?ed on the electrode,electrochemical responses could be improved signi?cantly.The modi?ed electrode could be applied in sensitive detection of Pb 2+by differential pulse anodic stripping voltammetry (DPASV).The 50wt%feeding ratio of MMT to aniline of the nanocomposite exhibited the best electrochemical response to Pb 2+.In 0.2mol L à1acetate buffer solution (pH 3.5),the stripping peak currents after enrichment at à1.20V for 120s showed good linear relationships with Pb 2+at concentration ranges of 4–100nM with the correlation coef?cient of 0.998,and the detection limit is 1nM.The proposed method is applicable in the determination of trace Pb 2+in real water samples with the relative standard deviations less than 5.2%and the recovery rates of 94–103%.

ó2014Published by Elsevier B.V.

1.Introduction

Lead is one of the most serious environmental contaminants which are highly toxic to nervous,immune,reproductive and gas-trointestinal systems of both humans and animals [1–3].Addition-ally,the accumulation of Pb 2+in the human body exhibits severe deleterious effects on neurobehavioral development in children,increases blood pressure,and causes kidney injury and anemia.Therefore,the development of a highly sensitive method for the determination of trace amounts of lead has received a considerable attention.Over the past decades,many techniques such as spectro-photometry,inductively coupled plasma optical emission spec-trometry,atomic absorption spectrometry,atomic ?uorescence spectrometry,and neutron activation analysis have been employed for the determination of heavy metals [4–9].However,most of the above methods require several time consuming manipulation steps,sophisticated instruments and special training.Electrochem-ical stripping voltammetry has been widely recognized as a power-ful technique for the determination of trace metal ions due to its unique ability to preconcentrate target metal ions during the accumulation step [10].The mercury electrodes including hanging drop mercury electrode,dropping mercury electrode and thin mer-cury ?lm electrode have been widely used as the working electrode in stripping voltammetry.However,the toxicity of mercury re-stricts its use.Ordinary electrochemical solid electrodes,such as glassy carbon,platinum,gold,and graphite electrodes are also not suitable for the determination of metal ions because of their poor sensitivity [11].Thus,it is very important to develop a sensi-tive,selective,and non-toxic electrode for the determination of heavy metals by stripping methods.Chemically modi?ed electrode (CME)might be the most suitable substitute for the traditional electrodes in the stripping voltammetry.Various CMEs have been exploited for anodic stripping voltammetric determination of trace metals,such as functionalized mesoporous silica electrode,carbon nanotubes modi?ed electrode,ordered mesoporous carbon,nano-crystalline diamond thin-?lm electrode,graphene modi?ed elec-trode,and graphite nano?ber–Na?on modi?ed bismuth ?lm electrode [12–19].Though CMEs have been widely used in the detection of metal ions,new materials still needed to improve the detection sensitivity and reproducibility in analysis of trace metals.

Recently,organic–inorganic nanocomposites have received con-siderable attention and many hybrid composite materials have been synthesized and studied [20].Conducting polymers and clay

https://www.360docs.net/doc/7814169751.html,/10.1016/j.jelechem.2014.01.0141572-6657/ó2014Published by Elsevier B.V.

?Corresponding authors.Tel.:+865552311807;fax:+865552311822.

E-mail addresses:

dongyp@https://www.360docs.net/doc/7814169751.html,

(Y.

Dong),

junchen@https://www.360docs.net/doc/7814169751.html,

(J.Chen).

are two frequently-used organic and inorganic materials which are widely used in the electrode modi?cation.Among the conducting polymers,polyaniline(PANI)is most famous and often used in the electrode modi?cation due to its simple synthesis,high con-ductivity,and excellent environment stability[21].When a PANI coating modi?ed glassy carbon electrode is immersed in a solution containing trace heavy metal ions,interactions occur between electron-rich sites and positively charged metal species and thus the metal ions are adsorbed onto the electrode surface and further separated from the bulk solution[22,23].However,the poor ther-mal stability and dif?cult processability of PANI should be over-come for the application of this electrically conducting polymer. Many reports have focused on the preparation and new property studies of novel nanocomposites consisting of PANI with various layered materials[24–29].Montmorillonite(MMT)is a layered sil-icate known for good swelling and ion-exchange properties[30]. MMT is also very popular inorganic matrix because of its layered nanostructure,natural origin,and availability at low cost.MMT has already been employed in electrochemical analysis because of its low cost and remarkable improvement in sensitivity,which attained attention for voltammetric determination of organic com-pounds and traces of heavy metal ions[31–36].In the last decade, the growth of the interest in PANI composites with montmorillon-ite has been observed.The composites of PANI and MMT were synthesized by mechanochemical reaction[37],in emulsion poly-merization[38],in situ deposition of PANI on MMT[39–41].The composite of MMT and conducting polymer has been applied in gas sensor and corrosion protection[42,43].However,to the best of our knowledge,PANI/MMT nanocomposite has not been re-ported in the detection of trace heavy metals.Therefore,in the present paper,PANI/MMT nanocomposite was synthesized and used to modify glassy carbon electrode(GCE).The modi?ed elec-trode was used to detect Pb2+in water samples by differential pulse anodic stripping voltammetry.

2.Experimental

2.1.Apparatus and reagents

All electrochemical experiments were performed with a model 760D CHI electrochemical workstation(Chenhua Instruments Co., Shanghai,China).A conventional three-electrode cell con?guration was employed for the voltammetric measurements.A PANI/MMT/ GCE(3-mm diameter disk)was used as the working electrode,with a saturated calomel reference electrode(SCE)and a platinum wire electrode for the reference and the counter electrode,respectively. Scanning electron microscopy(SEM)images were obtained on a Hitachi S-4800scanning electron microscope.

All chemicals employed in this work were of analytical-reagent grade and used without further puri?cation and solutions were prepared with doubly distilled water.Stock solutions of0.1mol Là1 Pb2+was prepared by dissolving Pb(NO3)2(Shanghai Reagent Cor-poration,China)into redistilled water,and then diluted to working solution at desired concentration with redistilled water.Aniline (99%),ammonium peroxydisulfate(APS),glycidyl methacrylate (GMA),diethanol amine(DEA)and2-Acrylamido-2-Methyl Pro-pane Sulfonic Acid(AMPS)were purchased from Sinopharm Chem-ical Reagent Co.,Ltd.Sodium montmorillonite(Na+-MMT)was obtained from Kunipia-F(Kunimine Co.).

2.2.Synthesis of PANI–MMT composites

The organic modi?cation of Na+–MMT clay with GMA–DEA is carried out according to the Ref.[44].The typical process is as follows:15g of Na+–MMT clay were fully dispersed in450mL redistilled water by stirring overnight at room temperature.An ex-cess of GMA–DEA(6.45g)was dissolved in50mL of redistilled water,then continuously and drop-wisely added to the clay disper-sion.The pH value of the mixture was adjusted to3by using hydrochloric acid.The mixture was stirred for6h.Afterward,the modi?ed MMT clay(hereinafter referred to as GMA–DEA–MMT) were?ltrated and washed several times to remove excess GMA–DEA and hydrochloric acid.Then,put150mL of2wt% GMA–DEA–MMT dispersion into a250mL round-bottom?ask equipped with a mechanical stirrer,a condenser,and nitrogen in-let.3.0g AMPS was then added and stirred under a nitrogen atmo-sphere by purging for30min.The initiator,0.03g APS(dissolved in 5mL of redistilled water),was?nally introduced in the reactor and the polymerization allowed to proceed at70°C for4h under a slow stream of nitrogen.The resulted dispersion was centrifuged and washed repeatedly with redistilled water to remove the un-grafted poly(AMPS).The obtained modi?ed MMT clay was dried at50°C in an oven.

The PANI/MMT is prepared by the chemical oxidation method as follows[44]:the certain amount of the PAMPS-g-MMT was well-dispersed in80mL of0.5mol Là1hydrochloric acid.Then, 0.8g aniline monomer was added and stirred for30min.The poly-merization started by introduction of APS solution(1.96g APS in 20mL of0.5mol Là1hydrochloric acid)drop-wisely.An overnight reaction was allowed to ensure completion of polymerization.The resultant precipitate was?ltered and sequentially washed with copious amounts of0.1mol Là1hydrochloric acid and industrial alcohol until the?ltrate was clear.Finally,the product was dried at50°C in an oven.

According to the aforementioned approach,numerous samples of the PANI/MMT nanocomposites with different MMT/aniline feeding ratio are obtained.The feeding ratio of MMT/aniline is de-?ned using following equation:

MMT=Aniline feeding ration?

W MMT

W Aniline

?100wt%

2.3.Preparation of the modi?ed GCE

Before modi?cation,the bare glassy carbon electrode was care-fully polished to a mirror with1.0l m,0.30l m and0.05l m alu-mina slurry on a polishing cloth,respectively.Then,rinsed thoroughly with doubly distilled water between each polishing step and washed successively with doubly distilled water,1:1(v/ v)HNO3aqueous solution and doubly distilled water in an ultra-sonic bath and dried in air,and used for the following experiments. The modi?er suspension was prepared by dispersing25mg of PANI/MMT in5.0mL of water under sonication for30min,giving a quite stable black suspension.The PANI/MMT modi?ed GCE(de-noted as PANI/MMT/GCE was prepared by casting10l L of the sus-pension on GCE surface using a micropipette and letting water evaporate in air.

2.4.Electrochemical detection of Pb(II)

DPASV was used for the observation of electrochemical behav-ior under optimized conditions.Pb were deposited at the potential ofà1.2V for120s by the reduction of Pb(II)in0.1M NaAc-HAc (pH 3.5).The Solid-phase extraction(SPE)procedures were performed by stirring the solution with a magnetic stirrer,which is included in the electrodeposition step.Following the preconcen-tration step,the stirring was stopped.After10s,DPASV was per-formed by potential scan fromà1.0V toà0.1V with amplitude of50mV,pulse width of50ms and potential step of4mV vs SCE.Aliquots of the Pb(NO3)2standard solution were introduced after the background signal was recorded.Prior to the next cycle,

Y.Dong et al./Journal of Electroanalytical Chemistry717-718(2014)206–212207

a 120s conditioning step at +0.3V (with solution stirring)was used to remove the previous residual P

b from the electrode sur-face.All the experiments were carried out at room temperature.3.Results and discussion

3.1.Characterization of PANI/MMT/GCE

The SEM image of PANI/MMT composite modi?ed glassy car-bon electrode (PANI/MMT/GCE)is depicted in Fig.1.The typical SEM image reveals that the obtained PANI/MMT is highly uni-form ?ake-like structure.The surface of ?ake-like PANI/MMT is rough,suggested that nanoscale PANI was formed on the MMT substrate.The homogeneous distribution of PANI particles on the MMT bring high roughness of nanocomposite and will increase the absorption ability of PANI ?lm in the detection of metal ions [44].

The PANI/MMT/GCE is also characterized by electrochemical methods.Fig.2shows the cyclic voltammetric response of a bare GCE,a MMT modi?ed GCE (MMT/GCE),a PANI modi?ed GCE (PANI/GCE)and a PANI/MMT/GCE in 0.1mol L à1phosphate buffer solution (PBS,pH 7.0).It could be found that currents of the bare GCE and the MMT/GCE in the PBS are extremely low and no elec-trochemical peaks are observed.One pair of electrochemical peaks are observed at the PANI/GCE,which should be related to the elec-trochemical reaction of the modi?ed PANI ?lm.There electrochem-ical peaks could also be observed at the PANI/MMT/GCE with the intensity increased greatly,suggesting that the PANI/MMT ?lm ex-hibit more electroactivity than that of pure PANI ?lm.It could be found from SEM image that well-dispersed nanoscale PANI parti-cles were deposited on the MMT layers.Therefore,it could be de-duced that electrochemical behavior of PANI could be suf?ciently improved through the deposition on the MMT substrate.From the electrochemical result and IR results reported in our previous work,it is obvious that PANI in the composite is its emeraldine salt [44].

The electrochemical impedance spectrum (EIS)is also used to characterize electron transfer ability of the modi?ed electrode

using Fe eCN T3à=4à

6redox couple as an indicator.The results are MMT/GCE is much smaller than

that of the bare GCE suggesting that the charge transfer is more facile on the modi?ed electrode.It is because that well-dispersed nanostructured PANI could greatly improve diffusion of target molecules [46].The result is in good accordance with that of cyclic voltammetry.

3.2.Electrochemical responses of the bare GCE and the PANI/MMT/GCE Fig.4shows the stripping performance the bare GCE and the PANI/MMT/GCE in 0.1M NaAc-HAc (pH 3.5)solution in presence and absence of 8l M Pb 2+.No stripping peak is observed in NaAc-HAc buffer solution either on the bare GCE or on the PANI/MMT/GCE,revealing that the PANI/MMT ?lm will not generate electrochemical response in NaAc-HAc solution.A very small and distorted stripping peak of Pb is observed at the bare GCE in 0.1M NaAc-HAc (pH 3.5)solution containing 8l M Pb 2+,suggest-ing that Pb 2+could not be sensitively detected at the bare GCE.The stripping peak of Pb at the PANI/MMT/GCE is strong,well-shaped,and symmetric.The not-zero background current at the modi?ed electrode is probable due to the charging current of nano-composite.The intensity of stripping peak increases nearly 5times compared with that of the bare GCE,revealed that Pb 2+could be detected sensitively at the PANI/MMT/GCE.

SEM image of the surface of PANI/MMT nanocomposite modi?ed electrode.

208Y.Dong et al./Journal of Electroanalytical Chemistry 717-718(2014)206–212

3.3.Effect of feeding ration of MMT to aniline and the amount of PANI/ MMT suspension

It has already proven that electroanalysis of heavy metal ions at the conducting polymer modi?ed electrode has received consider-able attention because the conducting polymer could enrich the target heavy metals and improve the analytical performance[47]. Among many layered materials,MMT have been extensively inves-tigated because of their large surface area and ion-exchange prop-erties[30].In the present work,MMT was used as the substrate for the deposition of PANI.It was found in our previous work that the MMT/aniline feeding ratio could affect the morphology of PANI/ MMT composites[44].Therefore,in the present study,different MMT/aniline feeding ratio of PANI/MMT composites(0.0%,12.5%, 25%,50%,75%,100%,125%)were prepared and the effects of these PANI/MMT composites on electrochemical response of Pb2+are comparatively examined and shown in Fig.5.It could be found that with the increase of MMT/aniline feeding ratio,the electrochemical signals of Pb2+increase correspondingly and reach the maximum at feeding ratio of50wt%.A further increase in the feeding ratio weakens the electrochemical signals.In the pure PANI?lm modi-?ed electrode,the aggregation of PANI particles will hamper its conductivity and result in low electrochemical signal.When PANI particles was deposited on MMT?lm,the adsorption ability to me-tal ions and the electrochemical behavior of the composite increase correspondingly.The reason is that MMT is a good substrate for the deposition of PANI particles and could prevent PANI particles from aggregation,which will improve the electrochemical response of metal ions.However,when the amount of MMT in the composite is too large,the conductivity of the modi?ed electrode will de-crease,as a result,the electrochemical signal decrease correspond-ingly.Therefore,the50%feeding ratio of MMT to aniline is chosen to synthesize MMT/PANI composite and used in the electrode modi?cation.

The voltammetric response of Pb2+is closely related to the thickness of PANI/MMT?lm which is determined by the volume of PANI/MMT suspension cast onto the GCE surface.The relation-ship between the volume of PANI/MMT suspension and the strip-ping peak current is examined and shown in Fig.5.The stripping peak current gradually increases as improving the volume of PANI/MMT suspension from0.0to10.0l L.However,the peak cur-rent conversely decreases with further increase of the volume of PANI/MMT suspension.As increasing the amount of PANI/MMT onto GCE surface,the active sits for Pb2+accumulation also in-crease.So,the stripping peak current shows enhancement.When the PANI/MMT?lm is too thick,the mass transport and charge transfer rate maybe conversely decrease,resulting in the decline of the peak current.Therefore,the optimized amount of PANI/ MMT is chosen as10l L.

3.4.Effect of electrochemical technologies

Among various anodic stripping voltammetry methods,square wave anodic stripping voltammetry(SWASV),linear sweep anodic stripping voltammetry(LSASV)and differential pulse anodic strip-ping voltammetry(DPASV)are often used.In order to obtain high-est sensitivity,these electrochemical techniques are comparatively used in the detection of Pb2+on the PANI/MMT/GCE as shown in Fig.6.It could be found that electrochemical signal of SWASV is similar with that of DPASV and is larger than that of LSASV.How-ever,the baseline of SWASV varies signi?cantly with the increase of applied potential while the baseline of DPASV changes a little under the same condition.Therefore,DPASV technique is used in the following electrochemical experiments.

Y.Dong et al./Journal of Electroanalytical Chemistry717-718(2014)206–212209

3.5.Effect of pH and acetate concentration

The effect of various supporting electrolytes including phos-phate,acetate,NH3–NH4Cl on the stripping peak currents of Pb2+ is investigated.The best electrochemical response is obtained in acetate buffer solution.Then,the effect of concentration of acetate buffer solution on the stripping peak current of Pb2+is investigated and the result is shown in Fig.7.As it can be seen,the optimal con-centration of acetate buffer solution is0.2mol Là1.Therefore, 0.2mol Là1acetate buffer solution is chosen as the supporting electrolytes in the following study.

The in?uence of pH on the determination of Pb2+is studied at a pH range from3.0to5.0.As shown in Fig.7,the peak current in-creases with increasing pH values and reaches a maximum value at pH3.5.The continuous increase in pH value results in a decrease in peak current.To achieve maximum sensitivity,the pH of acetate buffer solution is controlled to3.5in subsequent experiments. 3.6.In?uences of deposition time and deposition potential of Pb2+

The dependence of stripping peak current on accumulation time is studied and shown in Fig.8.As increasing the accumulation time,more Pb2+will be exchanged and adsorbed onto the surface of the PANI/MMT/GCE,so the stripping peak current will increase. As depicted in Fig.8,the stripping peak current of1l M Pb2+grad-ually increases with the accumulation time,indicating that the sensitivity of determination of Pb2+will increase as extending accumulation time.When accumulation time is longer than 120s,the curves of peak current vs time began to leave off.This can be attributed to saturation adsorption of Pb2+on the PANI/ MMT?lm.Therefore,120s is chosen to achieve high sensitivity and save analysis time.

The effect of deposition potential on metal stripping signals with the deposition time of120s in the range fromà0.8to à1.4V was also shown in Fig.8.When the accumulation potential shifts fromà0.80V toà1.20V,the stripping peak current in-creases greatly.As the accumulation potential becoming more neg-ative,Pb2+is reduced more completely,and consequently the stripping peak current increases.When the accumulation potential is negative thanà1.20V,the stripping peak current changes slightly,meanwhile,the background current increases greatly. Therefore,à1.20V is selected to obtain high sensitivity and better response.3.7.Calibration data

Calibration curves for the determination of Pb2+at the PANI/ MMT/GCE are achieved by DPASV under the optimal conditions. The DPASVs of different concentration of Pb2+are illustrated in Fig.9.The resulting calibration plots are linear over the range from4to100nM.The linear regression equation of Pb2+is Ip=1.08092Cà0.55133(Ip:l A,C:nM)with a correlation coef?cient of0.998.The detection limit of1nM is obtained at a sig-nal-to-noise ratio of3.

The comparison results of the proposed sensor with some reported sensors for the determination of Pb2+are given in Table1. It could be concluded that analytical performance of the PANI/ MMT/GCE in the detection of Pb2+is satisfactory.

3.8.Interferences

Under the optimal conditions,the interference study is carried out by adding various foreign substances into a standard solution which contained 1.0?10à6mol Là1of Pb2+and0.2mol Là1 NaAc-HAc(pH3.5).The ratios of interference for a±5.0%signal change relative to1.0?10à6mol Là1of Pb2+are listed as follows: 3000for K+,Na+,Clà,NO3à;600for Mg2+,Zn2+,Ca2+;300for

210Y.Dong et al./Journal of Electroanalytical Chemistry717-718(2014)206–212

Ba2+and Fe3+;100for Co2+,Cd2+and Cr3+;20for Cu2+,Ni2+.The cat-ionic components can compete for the binding sites on the elec-trode surface and the anions may act as either complexing or oxidation agents.It is found that Ni2+and Cu2+have signi?cant in?uence on the stripping response at low mass ratio.This is be-cause Ni2+and Cu2+can form intermetallic compounds with Pb2+ and prevent its accumulation on the electrode.The interference of Cu2+and Ni2+could be released by the addition of ferrocyanide as suggested in Ref.[45].

3.9.Analysis of a real sample

The PANI/MMT/GCE is employed for determination of Pb2+in three real samples from local environment including tap water, water from Yushan lake and Lian lake.All water samples are used without?ltered in advance,and then added to0.2mol Là1ace-tate buffer(pH 3.5)and determined under the optimal condi-tions.The experimentally results are shown in Table2.Pb2+is not found in these water samples.The results con?rm the good application potential of the present method for real water samples.

4.Conclusions

In this study,PANI/MMT nanocomposite modi?ed electrode was used to detect heavy metals in real water samples by differen-tial pulse anodic stripping voltammetry.The result revealed that trace lead ions in water samples could be sensitively detected at the modi?ed electrode.The high sensitivity of this modi?ed elec-trode for analysis of Pb2+opens the possibility to consider the PANI/MMT/GCE as a good alternative to mercury-based electrodes. Owing to the environmentally friendly decorate material,inexpen-sive instrumentations,and simple operation,the methods will of-fer potential applications for monitoring of Pb2+in environmental samples.Acknowledgements

This work is?nancially supported by National Natural Science Foundation of China(No.61271156,No.21207001),China Post-doctoral Science Foundation(2013M541637)and Innovation Team Project of AHUT(No.TD201204).

References

[1]D.D.Runnells,T.A.Shepherd,E.E.Angino,Environ.Sci.Technol.26(1992)

2316–2323.

[2]T.Kemper,S.Sommer,Environ.Sci.Technol.36(2002)2742–2747.

[3]A.Jang,Y.Seo,P.L.Bishop,Environ.Pollut.133(2005)117–127.

[4]K.Leopold,M.Foulkes,P.J.Worsfold,Trends Anal.Chem.28(2009)426–435.

[5]N.Pourreza,H.Parham,A.R.Kiasat,K.Ghanemi,N.Abdollahi,Talanta78

(2009)1293–1297.

[6]H.Bagheri,A.Afkhami,M.Saber-Tehrani,H.Khoshsafar,Talanta97(2012)87–

95.

[7]A.Afkhami,T.Madrakian,H.Siampour,Int.J.Environ.Anal.Chem.86(2006)

1165–1173.

[8]A.Afkhami,M.Saber-Tehrani,H.Bagheri,J.Hazard.Mater.181(2010)836–

844.

[9]Y.Li,Y.Jiang,X.P.Yan,Z.M.Ni,Environ.Sci.Technol.36(2002)4886–4891.

[10]K.Kalcher,J.M.Kauffmann,J.Wang,I.Svancara,K.Vytras,C.Neuhold,Z.Yang,

Electroanalysis7(1995)5–22.

[11]E.A.McGaw,G.M.Swain,Anal.Chim.Acta575(2006)180–189.

[12]W.Yantasee,L.A.Deibler,G.E.Fryxell, C.Timchalk,Y.H.Lin,Electrochem.

Commun.7(2005)1170–1176.

[13]D.Sun,X.F.Xie,Y.P.Cai,H.J.Zhang,K.B.Wu,Anal.Chim.Acta581(2007)27–

31.

[14]H.Xu,L.P.Zeng,S.J.Xing,Y.Z.Xian,G.Y.Shi,L.T.Jin,Electroanalysis20(2008)

2655–2662.

[15]L.D.Zhu,C.Y.Tian,R.L.Yang,J.L.Zhai,Electroanalysis20(2008)527–533.

[16]P.Sonthalia,E.McGaw,Y.Show,G.M.Swain,Anal.Chim.Acta522(2004)35–

44.

[17]J.Li,S.J.Guo,Y.M.Zhai,E.K.Wang,Anal.Chim.Acta649(2009)196–201.

[18]J.Li,S.J.Guo,Y.M.Zhai,E.K.Wang,https://www.360docs.net/doc/7814169751.html,mun.11(2009)1085–

1088.

[19]D.Y.Li,J.B.Jia,J.G.Wang,Talanta83(2010)332–336.

[20]C.Sanchez,G.J.de A.A.Soler-Illia,F.Ribot,https://www.360docs.net/doc/7814169751.html,lot,C.R.Mayer,V.Cabuil,Chem.

Mater.13(2001)3061–3083.

[21]I.Sapurina,J.Stejskal,Polym.Int.57(2008)1295–1325.

[22]P.R.Singh,A.Q.Contractor,Int.J.Environ.Anal.Chem.85(2005)831–835.

[23]Q.F.Lu,M.R.Huang,X.G.Li,Chem.Eur.J.13(2007)6009–6018.

[24]C.G.Wu,D.C.DeGroot,H.O.Marcy,J.L.Schindler,C.R.Kannewurf,T.Bakas,V.

Papaefthymiou,W.Hirpo,J.P.Yesinowski,Y.J.Liu,M.G.Kanatzidis,J.Am.

Chem.Soc.117(1995)9229–9242.

[25]M.G.Kanatzidis,C.G.Wu,J.Am.Chem.Soc.111(1989)4139–4141.

[26]Q.Wu,Z.Xue,Z.Qi,F.Wang,Polymer41(2000)2029–2032.

[27]B.H.Kim,J.H.Jung,J.W.Kim,H.J.Choi,J.Joo,Synth.Met.117(2001)115–118.

[28]S.M.Yang,K.H.Chen,Synth.Met.135(2003)51–52.

[29]W.Jia,E.Segal,D.Kornemandel,https://www.360docs.net/doc/7814169751.html,mhot,M.Narkis,A.Siegmann,Synth.

Met.128(2002)115–120.

[30]G.M.do Nascimento,V.R.L.Constantino,https://www.360docs.net/doc/7814169751.html,nders,M.L.A.Temperini,Polymer

47(2006)6131–6139.

[31]P.Falaras,F.Lezou,P.Pomonis,https://www.360docs.net/doc/7814169751.html,davos,J.Electroanal.Chem.486(2000)

156–165.

[32]D.Orata,F.Segor,React.Funct.Polym.43(2000)305–314.

[33]K.G.Bhattacharyya,S.S.Gupta,Adv.Colloid Interface Sci.140(2008)114–131.

[34]P.Manisankar,G.Selvanathan,C.Vedhi,Appl.Clay Sci.29(2005)249–257.

[35]P.Manisankar,G.Selvanathan,C.Vedhi,Talanta68(2006)686–692.

Table1

Comparison of some characteristics of the different modi?ed electrodes reported for the determination of Pb2+.

Electrode Modi?er Method LOD(l mol Là1)Linear range(l mol Là1)Ref

CPE Kaolinite DPASV0.0840.3–20[48] CMCPE IL MWCNT-Schiff base SWASV 1.2?10à4 1.9?10à3–5.3[49] Graphene Bi NPs/PANI SWASV 3.3?10à40.1–1.1[50] GCE Thiol-PANI/MWCNTs DPASV 1.9?10à4 4.8?10à4–0.14[51] CNT Gold NPs SWASV 2.6?10à30.016–0.11[52] CPE RGO/Bi DPASV 2.7?10à30.097–0.58[53] Gold Graphene OSWV– 4.0?10à4–0.2[54] Graphene Bi SWASV–0.3–1.7[55] CPE MWCNT/Schiff base SWASV 6.4?10à4 2.5?10à3–0.7[56] GCE BiF/GNFs-Na?on DPASV9.7?10à59.7?10à4–0.24[19] GCE PANI/MMT DPASV 1.0?10à3 4.0?10à3–0.1Present work

CPE:carbon paste electrode,DPASV:differential pulse anodic stripping voltammetry,SWASV:square-wave anodic voltammetry,OSWV:Osteryoung square wave voltam-metry,MWCNT:multi-wall carbon nanotube,RGO:reduced graphene oxide,NPs:nanoparticles.

Table2

Analytical results of lead in water samples and recovery studies.

Sample Added(nM)Found a(nM)RSD(%)Recovery(%)

Tap water0–––

4038.4 3.596.0

Yushan lake0–––

4041.3 4.3103.2

Lian lake0–––

4038.6 5.296.5

a Mean of three determinations.

Y.Dong et al./Journal of Electroanalytical Chemistry717-718(2014)206–212211

[36]B.Muralidharan,G.Gopu,C.Vedhi,P.Manisankar,Appl.Clay Sci.42(2008)

206–213.

[37]S.Yoshimoto,F.Ohashi,Y.Ohnishi,T.Nonami,Synth.Met.145(2004)265–

270.

[38]B.H.Kim,J.H.Jung,S.H.Hong,J.Joo,A.J.Epstein,K.Mizoguchi,J.W.Kim,H.J.

Choi,Macromolecules35(2002)1419–1423.

[39]J.M.Yeh,S.J.Liou,https://www.360docs.net/doc/7814169751.html,i,P.C.Wu,T.Y.Tsai,Chem.Mater.13(2001)1131–

1136.

[40]G.M.do Nascimento,V.R.L.Constantino,M.L.A.Temperini,Macromolecules35

(2002)7535–7537.

[41]W.J.Bae,K.H.Kim,W.H.Jo,Macromolecules37(2004)9850–9854.

[42]L.F.B.L.Pontes,J.E.G.de Souza,A.Galembeck,C.P.de Melo,Sens.Actuat.B177

(2013)1115–1121.

[43]M.G.Hosseini,M.Jafari,R.Najjar,Surf.Coat.Technol.206(2011)280–286.

[44]J.Chen,X.Q.Hong,Y.T.Zhao,Y.Y.Xia,D.K.Li,Q.F.Zhang,J.Mater.Sci.48(2013)

7708–7717.

[45]K.Crowley,J.Cassidy,Electroanalysis14(2002)1077–1082.

[46]J.X.Huang,S.Virji,B.H.Weiller,B.B.Kaner,Chem.Eur.J.10(2004)1314–1319.[47]M.D.Imisides,R.John,P.J.Riley,G.G.Wallace,Electroanalysis3(1991)879–

889.

[48]Y.Gomez,L.Fernandez,C.Borras,J.Mostany,B.Scharifker,Talanta85(2011)

1357–1363.

[49]A.Afkhami,H.Ghaedi,T.Madrakian,M.Rezaeivala,Electrochim.Acta89

(2013)377–386.

[50]Z.M.Wang,L.Li,E.J.Liu,Thin Solid Films544(2013)362–367.

[51]Z.H.Su,Y.Liu,Y.Zhang,Q.J.Xie,L.Chen,Y.Huang,Y.C.Fu,Y.Meng,X.J.Li,M.

Ma,S.Z.Yao,Analyst138(2013)1180–1186.

[52]M.P.Ngoc Bui,C.A.Li,K.N.Han,X.H.Pham,G.H.Seong,Analyst137(2012)

1888–1894.

[53]P.K.Sahoo,B.Panigrahy,S.Sahoo,A.K.Satpati,D.Li,D.Bahadur,Biosens.

Bioelectron.(2013)293–296.

[54]N.Kong,J.Q.Liu,Q.S.Kong,R.Wang,C.J.Barrow,W.R.Yang,Sens.Actuat.B178

(2013)426–433.

[55]Z.M.Wang,P.M.Lee,E.J.Liu,Thin Solid Films544(2013)341–347.

[56]A.Afkhami,H.Bagheri,H.Khoshsafar,M.Saber-Tehrani,M.Tabatabaee,A.

Shirzadmehr,Anal.Chim.Acta746(2012)98–106.

212Y.Dong et al./Journal of Electroanalytical Chemistry717-718(2014)206–212

振动测试系统

一、振动测试系统 1.主要功能 DASP V10振动测试系统包括信号采集和实时分析软硬件。DASP V10 是一套运行在Windows95/98/Me/NT/2000/Xp平台上的多通道信号采集和实时分析软件,通过和东方所的不同硬件配合使用,即可构成一个可进行多种动静态试验的试验室。DASP V10 软件既具有多类型视窗的多模块功能高度集成特性,具有操作便捷的特点。基于东方所在各种工程应用领域的长期经验,DASP-V10对各种功能模块重新进行整合,成为一套功能更加全面、操作更加便捷、界面更加美观、性能继续保持领先的动静态信号测试分析系统。DASP V10 软件的每一个模块中均包含了非常多的功能,各种功能可交错使用,在测试和分析的功能和性能上突破了以往信号分析仪的种种限制,与INV系列采集仪配合形成的系统的各项指标均可达到或超过国家高级仪器的标准。DASP V10 软件的所有测试分析结果都可以多种方式输出,包括图形的复制、存盘、打印,数据导出为TXT、CSV、Excel电子表格和Access数据库格式,并可轻松输出图文并茂的Word格式或者Html格式的分析报告。基于DASP V10 的平台上,还可以运行专业模态和动力学分析系统、虚拟仪器库、信号发生器以及针对声学、旋转机械、路桥土木、计量检定等行业的多种软件系统,满足各方面各层次的测试和分析需求。

3.隶属 (1)实验室:水机测控实验室(B01-205/207) (2)负责人:魏德华 二、ANSYS/CFD流体分析软件 1.主要功能 FLUENT、CFX是目前国际上比较流行的商用CFD软件包,国际市场占有率达70%。凡跟流体、热传递及化学反应等有关的领域均可使用。它具有丰富的物理模型、先进的数值方法以及强大的前后处理功能,在航空航天、汽车设计、石油天然气、涡轮机设计等方面都有着广泛应用,包括管路、渠道、流体机械、燃烧、环境分析、油气消散/聚积、喷射控制、多相流等方面的流动计算分析。 2.主要设备 3.隶属 (1)实验室:水机测控实验室(B01-205/207) (2)负责人:石祥钟

振动信号检测系统的设计1

信号检测综合训练 说明书 题目:振动信号检测系统设计 学院:电气工程与信息工程学院 班级:电子(2)班 姓名: 钱鹏鹏 学号:11260224 指导老师:缑新科 2014.12.07

摘要 机械在运动时,由于旋转体的不平衡、负载的不均匀、结构刚度的各向异性、间隙、润滑不良、支撑松动等因素,总是伴随着各种振动。机械振动在大多情况下是有害的,振动往往会降低机器性能,破坏其正常工作,缩短使用寿命,甚至导致事故。机械振动还伴随着同频率的噪声,恶化环境,危害健康。另一方面,振动也被利用来完成有用工作,如运输、夯实、清洗、粉碎、脱水等。这时必须正确选择振动参数,充分发挥振动机械的性能。在现代企业管理制度中,除了对各种机械设备提出低振动和低噪声要求外,还需随时对机器的运行状况进行监测、分析、诊断,对工作环境进行控制。为了提高机械结构的抗振性能,有必要进行机械机构振动分析和振动设计,这些都离不开振动测试。 本文在此基础上设计了一种专用的振动信号检测系统,具有功耗低、体积小、精度高等优点。 信号检测的内容要求: 通过MCS-51系列单片机设计振动信号检测系统。要求如下: 1 振动信号的特点,选择合适的传感器,并设计相应的检测电路; 2 将设计完成的检测电路,通过软件防真验证; 3 主要设计指标:可测最大加速度:-5m/s~+5m/s;可测最大速度:-0.16m/s~+0.16m/s;可测最大位移:-5mm~+5mm;通频带:0.05Hz~35Hz;转换精度:8bit;采样频率:128Hz 4 利用LCD显示振动信号,有必要的键盘控制。

总体设计方案介绍: 本系统由发射电路和接收电路组成。发射电路主要由加速度传感器构成。接收电路由单片机最小系统和外部串口以及显示部分模块三部分组成。。 硬件电路设计: (1)使用MMA8452加速度传感器和STC89C52单片机来实现。 一.设计目的:了解加速度传感器的工作机理,以及单片机的各种性能; 二.设计器材:电源、proteus7.7软件、89C52,MMA8452加速度传感器,导线若干。 三.设计方案介:该系统目的是便于对一些物理量进行监视、控制。本设计以加速度传感器显示出加速度信号即振动信号,再通过单片机将信号从串口接入电脑显示出来,即完成振动信号的检测功能。 (2)振动传感器的分类 1、相对式电动传感器 电动式传感器基于电磁感应原理,即当运动的导体在固定的磁场里切割磁力线时,导体两端就感生出电动势,因此利用这一原理而生产的传感器称为电动式传感器。 相对式电动传感器从机械接收原理来说,是一个位移传感器,由于在机电变换原理中应用的是电磁感应电律,其产生的电动势同被测振动速度成正比,所以它实际上是一个速度传感器。 2、电涡流式传感器 电涡流传感器是一种相对式非接触式传感器,它是通过传感器端部与被测物体之间的距离变化来测量物体的振动位移或幅值的。电涡流传感器具有频率范围宽(0~10 kHZ),线性工作范围大、灵敏度高以及非接触式测量等优点,主要应用于静位移的测量、振动位移的测量、旋转机械中监测转轴的振动测量。 3、电感式传感器 依据传感器的相对式机械接收原理,电感式传感器能把被测的机械振动参数的变化转换成为电参量信号的变化。因此,电感传感器有二种形式,一是可变间隙,二是可变导磁面积。 4、电容式传感器 电容式传感器一般分为两种类型。即可变间隙式和可变公共面积式。可变间隙式可以测量直线振动的位移。可变面积式可以测量扭转振动的角位移。 5、惯性式电动传感器 惯性式电动传感器由固定部分、可动部分以及支承弹簧部分所组成。为了使传感器工作在位移传感器状态,其可动部分的质量应该足够的大,而支承弹簧的刚度应该足够的小,也就是让传感器具有足够低的固有频率。根据电磁感应定律,感应电动势为:u=Blx&r 。式中B为磁通密度,l为线圈在磁场内的有效长度,r x&为线圈在磁场中的相对速度。 从传感器的结构上来说,惯性式电动传感器是一个位移传感器。然而由于其输出的电信号是由电磁感应产生,根据电磁感应电律,当线圈在磁场中作相对运动

IT运维管理系统使用手册

IT运维管理系统 用户使用手册 大庆和光电子科技开发有限公司 二〇一六年十月

目录 1、基础信息 (3) 1.1项目信息 (3) 1.2项目检查项 (4) 1.3设备基础信息 (6) 2、日常巡检 (8) 2.1软件日巡检 (8) 2.2软件周巡检 (9) 2.3服务器系统巡检 (10) 2.4服务器硬件巡检 (10) 3、巡检查询 (11) 3.1软件日常巡检检查 (11) 3.2服务器巡检报告 (11) 4、运维资料管理 (12) 4.1系统问题管理 (12) 4.2项目资料管理 (15)

1、基础信息 1.1项目信息 主要录入各运维组所维护的项目信息,各运维组各自录入各自的项目信息。如下图所示 【新增】按钮:点击“新增”按钮,按要求添加项目信息,点击“确认保存”按钮即可。如图所示: 注:状态字段:有两个状态,分别是“正常”和“停用”。当状态是“正常”,则在软件日/周巡检中显示;当状态是“停用”,则在软件日/周巡检中不显示。 项目路径:填写该项目发布的位置,例如:D:\Publish

【编辑】按钮:点击“编辑”按钮,编辑已添加的项目信息,点击“确认保存”按钮即可。如图所示: 【删除】按钮:选中要删除项目前的复选框,点击“删除”按钮,确定要删除,点击“确认”按钮即可。如图所示: 1.2项目检查项 主要是录入各运维组巡检项目的检查项,各运维组录入各自的项目检查项信息,如下图所示

【新增】按钮:点击“新增”按钮,按要求添加项目的检查项信息,点击“确认保存”按钮即可。如图所示: 【编辑】按钮:点击“编辑”按钮,编辑已添加的项目的检查项信息,点击“确认保存”按钮即可。如图所示:

软件系统运维手册(完整资料).doc

【最新整理,下载后即可编辑】 系统运维手册 1、目的 (3) 2、适用范围 (3) 3、服务器及数据库概述 (3) 3.1 服务器概述 (3) 3.2 数据库概述 (3) 4、系统服务程序的详细说明 (4) 4.1系统服务程序的构成 (4)

4.2 系统服务程序的启动、关闭及维护管理 (4) 4.2.1 dhcp主服务 (4) 4.2.2 dhcp从服务 (5) 4.2.3 web管理模块 (5) 5、服务器硬件维护(略) (6) 6、windows 2003系统的日常维护 (6) 6.1 定期检查磁盘空间 (6) 6.2 维护系统注册表 (7) 6.3 定期备份系统注册表 ..................................................................... 7 6.4清理system路径下的无用的dll文件 (7) 7、备份策略 (8) 7.1 备份方式 (8) 7.2 备份计划 (8) 7.3 常见故障恢复 (8) 9、数据库的日常维护 (11) 9.1 检查数据库的基本状况 (11) 9.2 检查数据库日志文件 (11) 9.4监控数据库表空间的使用情况(字典管理表空间) (11) 9.4.1 判断是否需要碎片整理 (11) 10、命令解释 (12) 1、目的 楚天行消费卡管理系统运营支撑系统使用的服务器中,服

务器均采用windows xp操作系统,数据库版本为:sql server 2000,随着业务的开展,sql server 数据库中存储的数据量也不断增大,这样操作系统和数据库的日常维护就显得十分重要。 本手册详细描述了程序模块,windows xp操作系统,负载平衡及sql server 数据库等日常检查的主要步骤,指导现场工程师对其进行监控和维护。 2、适用范围 使用者为网e通宽带网络运营支撑系统维护工程师 3、服务器及数据库概述 3.1 服务器概述 服务器数量:4台,基本信息如下: 3.2 数据库概述 数据库软件分别安装在主服务器上。 4、系统服务程序的详细说明 4.1系统服务程序的构成 DHCP主程序:

系统维护手册

系统维护手册 Revised as of 23 November 2020

密级:内部公开 文档编号:LANDUNTEC_SD_TEMP_08 版本号: 分册名称:第1册/共1册 系统维护手册 中国普天信息产业股份有限公司 中国普天信息产业股份有限公司对本文件资料享受着作权及其它专属权利,未经书面许可,不得将该等文件资料(其全部或任何部分)披露予任何第三方,或进行修改后使用。 文件更改摘要:

目录

1. 适用范围 该手册适用于系统管理员及系统维护人员适用。 2. 系统运行环境 3. 3.1. 数据库环境 3.2. 服务器信息: 安装软件:

数据库配置: Jdk及mysql软件是分别安装在22服务器和26 服务器上的。Mysql的数据库管理信息配置如下: 全局数据库名:cms 数据库别名:cms 数据库管理员用户:root密码: 3.3. Web环境 3.4. Web服务器为虚拟操作系统。 系统信息: 服务器网络配置: 4. 系统运维计划 4.1. 运维目标 集中监控平台管理系统运维管理的目标是保证系统平台的正常、可靠、高速运行,保证对突发事件、需求变更进行快速响应,保证规费管理系统的信息完整。

4.3. 系统平台维护: 保证操作系统、数据库系统、中间件、其他支撑系统应用的软件系统及网络协议等安全性、可靠性和可用性而实施的维护与管理;及时排除系统故障;每月对系统平台进行一次巡检,及时消除故障隐患,保障系统的安全、稳定、持续运行。 应用系统管理和维护: 在系统维护过程中采取各种技术手段及时排除系统故障,保证系统及相应接口的安全性、可靠性和可用性。及时消除系统可能存在的安全隐患和威胁、根据需求更新或变更系统功能。 数据储存设施管理和维护: 为保证数据存储设施、如服务器设备、集群系统、存储网络及支撑数据存储设施运行的软件平台的安全性、可靠性和可用性,保证存储数据的安全。定期对系统的性能,确认数据存储的安全,及时消除故障隐患,保障系统安全、稳定、持续运行。 数据管理和维护: 数据管理是系统应用的核心。为保证数据存储、数据访问、数据通信、数据交换的安全,每月对数据的完整性、安全性、可靠性进行检查。

软件系统运维手册范本

系统运维手册

1、目的 (3) 2、适用围 (3) 3、服务器及数据库概述 (3) 3.1 服务器概述 (3) 3.2 数据库概述 (3) 4、系统服务程序的详细说明 (3) 4.1系统服务程序的构成 (3) 4.2 系统服务程序的启动、关闭及维护管理 (4) 4.2.1 dhcp主服务 (4) 4.2.2 dhcp从服务 (5) 4.2.3 web管理模块 (5) 5、服务器硬件维护(略) (6) 6、windows 2003系统的日常维护 (6) 6.1 定期检查磁盘空间 (6) 6.2 维护系统注册表 (7) 6.3 定期备份系统注册表 (7) 6.4清理system路径下的无用的dll文件 (7) 7、备份策略 (8) 7.1 备份方式 (8) 7.2 备份计划 (8) 7.3 常见故障恢复 (8) 9、数据库的日常维护 (11) 9.1 检查数据库的基本状况 (11) 9.2 检查数据库日志文件 (11) 9.4监控数据库表空间的使用情况(字典管理表空间) (11) 9.4.1 判断是否需要碎片整理 (11) 10、命令解释 (12)

1、目的 楚天行消费卡管理系统运营支撑系统使用的服务器中,服务器均采用windows xp操作系统,数据库版本为:sql server 2000,随着业务的开展, sql server 数据库中存储的数据量也不断增大,这样操作系统和数据库的日常维护就显得十分重要。 本手册详细描述了程序模块,windows xp操作系统,负载平衡及sql server 数据库等日常检查的主要步骤,指导现场工程师对其进行监控和维护。 2、适用围 使用者为网e通宽带网络运营支撑系统维护工程师 3、服务器及数据库概述 3.1 服务器概述 3.2 数据库概述 数据库软件分别安装在主服务器上。 4、系统服务程序的详细说明 4.1系统服务程序的构成

汽车发动机振动噪声测试系统

附件1 汽车发动机振动噪声测试系统 1用途及基本要求: 该设备主要用于教学和科研中的振动和噪声测量,要求能够测量试验对象的振动噪声特性(频率、阶次、声强等),能对试验数据进行综合分析。该产品的生产厂应具有多年振动噪声行业从业经验,有较高的知名度和影响力。系统软件和硬件应该为成熟的模块化设计,同时具有很强的扩展能力,能保证将来软件和硬件同时升级。 2设备技术要求及参数 2.1设备系统配置 2.1.1数据采集系统一套; 2.1.2数据测试分析软件一套; 2.1.3传声器 2个; 2.1.4加速度计 2个; 2.1.5声强探头 1套; 2.1.6声级校准器 1个; 2.1.7笔记本电脑一台 2.2数据采集、控制系统技术要求 2.2.1主机箱一个;供电采用9~36V直流和 200~240V交流; 2.2.2便携式采集前端,适用于实验室及现场环境; 2.2.3整机消耗功率〈150W; 2.2.4工作环境温度:—10?C ~50?C; 2.2.5中文或英文WindowsXP下运行,操作主机采用笔记本电脑; 2.2.6输入通道数:4个以上,其中2个200V极化电压输入通道、不少一个转速输入通道; 2.2.7输入通道拥有Dyn-X技术,动态范围160dB; 2.2.8每通道最高采样频率:≥65.5kHz,最大分析带宽:≥25.6kHz; 2.2.9系统留有扩充板插槽,根据需要可以进一步扩充;数据采集前端可同时连接多种形式传感器,包括加速度计、转速探头、传声器、声强探头等; 2.2.10系统具有堆叠和分拆能力,多个小系统可组成多通道大系统进行测量。大系统可分拆成多个小系统独立运行; 2.2.11采集前端的数据传输具备二种方式之一:①通过10/100M自适应以太网传输至PC; ②通过无线通讯以太网技术传输至PC,通信距离在100米以上。使测量过程更为灵活方便,方便硬件通道和计算机系统扩展升级;

运维手册文件

X X体检系统 维护手册 修订记录 版本号编写日期编制人审核人/ 批准人修改章节号 1.0 初始版本 XX软件股份有限公司

目录 1 概述 (3) 1.1 系统结构 (3) 1.2 数据库分布 (4) 2 运维环境介绍 (5) 2.1 服务器配置及端口互通关系 (5) 2.2 开发运行环境 (6) 2.2.1 数据库 (6) 2.2.2 插件(软件) (6) 2.2.3 系统运行所需JDK (7) 2.2.4 网络 (7) 3 基本维护 (8) 3.1 业务软件安装 (8) 3.2 新增功能页面 (8) 3.3 配置文件参数配置 (8) 3.4 数据库维护 (9) 4 账户信息 (10) 4.1 登录服务器 (10) 4.2 数据库 (10) 4.3 其他问题..................................................................................... 错误!未定义书签。

关键词: 摘要:本手册对系统运行环境、主要配置文件、系统新数据录入方法等进行了介绍,说 明了主要运维工作的处理,以及常见问题的处理。 1概述 1.1 系统结构 系统采用的结构描述 用户 预约网站、APP 体检系统检验系统影像系统 portal bs_tjxt bslis52 bs_tjxt_photo 业务平台结构图

1.2 数据库分布 Portal Bs_tjxt bslis52 bs_tjxt_photo 数据分布图 portal 为门户系统数据库 bs_tjxt 为体检系统数据库 bslis52 为检验数据库 bs_tjxt_photo 为影像数据库 1.3 数据接口 各系统之间的数据调用关系如下图所示: 影像系统 体检系统检验系统 体检 者信 息 结果 像 影检 验 项 目 、 检 检验 条 验结 果 码 bs_tjxt_photo bslis52 portal bs_tjxt 数据调用关系图 1、体检-检验接口:体检系统登记人员信息,产生检验项目信息与检验条码后,将 这些信息插入bslis52 数据库里的l_jytmxx 表。检验系统得到检验项目的结果后,生成结 果视图vi_tj_result ,体检系统的项目与该视图结果进行对照后获取检验结果。 2、体检-影像接口:

机械振动测试系统综述

机械振动测试系统综述 翟 慧 强 张 金 萍 于 玲 王 丹 (沈阳化工大学 机械工程学院,辽宁 沈阳 110142) 摘 要:机械振动测试技术在工业生产中起着十分重要的作用,为此设计和制造高效的机械振动测试系统便成为测试技术的重要内容。本文首先概述了机械振动测试系统的发展历程。总结和分析了发展机械振动 测试系统的基本组成和应用理论。根据不同原理列举了几种机械振动测试系统的类型并对不同的机械振动 测试系统进行分析,探讨了他们的优点和不足。最后在此基础上分析了机械振动测试系统的几个发展趋势和 系统建设中仍然要注意的抗干扰问题和故障诊断问题。 关键词:机械振动测试系统;测试技术;抗干扰;故障诊断 1 引言 振动问题广泛存在于热门的生活和生产当中。建筑物、机器等在内界或者外界的激励下就会产生振动。而机械振动常常会破坏机械的正常工作,甚至会降低机械的使用寿命并对机器造成不可逆的损坏多数的机械振动是有害的。因而对振动的研究不仅有利于改善人们的生活环境和生活水平,也有助于提高机械设备的使用寿命,提高人们的生产效率。正因如此振动测试在生产和科研等多方面都有着十分重要的地位[1]。为了控制振动,将振动给人们带来的危害降至最低,就需要我们了解振动的特性和规律,对振动进行测试和研究。振动测试系统应运而生。 振动测试系统有着较为长久的发展历史,是与人类社会的发展有着紧密的联系。随着计算机技术和相关高科技技术的问世和发展,振动测试系统也有了飞跃性的发展。振动测试系统从最早的简单机械设备的应用到如今的先进的计算机技术和设备的应用。从刚开始的检测人员的耳朵来进行测量、判断和计算出大概的故障点的原始方法到现在的计算机控制、存储、处理数据的处理[2]。无不体现出振动测试系统的长足发展和飞跃式的进步。与此同时,机械振动测试在理论方面也有了长足的发展,1656年惠更斯首次提出物理摆的理论并且创造出了单摆机械钟到现今的自动控制原理和计算机的日趋完善,人们对机械振动分析的研究已日趋成熟。而伴随着振动测试系统的进步和日臻成熟,其在国民的日常生活和生产中所扮演的角色也愈发的重要。 2机械振动测试系统的基本理论与组成 机械振动测试就是利用现代一些测试手段,对所研究物体的机械振动进行测量,并对测得的信号进行更细致的分析,以期获得在各种工作状态下物体的机械振动特性,从而判断物体的机械振动特性是否符合要求。 振动测试系统主要由传感器、信号调节部分、数模转换器、信号处理部分和数据记录部分、反馈部分等组成。传感器是将被测量转换成某种电信号的部件。是整个测试系统最重要的组成部分。信号调节部分是把传感器的输出信号转换成适合于进一步传输和处理的形式。经过加工处理使得原始信号更加便于分析和处理。这种信号的转换多数是电信号直接的转换。信号处理部分是对来自信号调节环节的信号进行各种运算和分析。这也是测试的核心意义所在,包括对时域和频域的分析,已得到各种参数。数模转换器是采用计算机等进行测试、控制系统时进行模拟信号与数字信号的相互转换的环节。测试系统的主要作用是更加便捷易懂的将初试信号转换成某种信号进行提取分析。因此最重要的是信号不能失真,不出现扰动。这就对测试系统提出了较为严格的要求[3]。 3.振动测试系统的分类 近几年来,振动测试理论与方法都有了很大的发展。目前振动测试方法按其原理不同可以分为四类。直观类、光学类、机械类和电测类。直观法操作简便,不受各种器材的限制。

基于labview振动测试系统

基于LabVIEW的振动信号测试系统设计 摘要:虚拟仪器是现代计算机技术同仪器技术深层次结合的全新概念仪器,实质是利用计算机的显示器的显示功能模拟传统仪器的控制面板,以多种形式表达输出测量结果,利用计算机强大的软件功能实现信号数据的运算、分析和处理,完成各种测试功能的一种计算机仪器系统。 本次设计利用了基于LabVIEW的虚拟仪器技术设计了一套振动测试系统,下位机采用AT89C52单片机进行数据采样,并通过RS-232串口与上位机通信实现信号数据的传输,上位机软件开发基于LabVIEW平台。其具有信号采集,波形显示,数据处理,数据保存,信号参数检测等功能,具有操作简单,界面直观,适用性强等特点。通过设计,能够对数据进行时域显示和频域分析处理。 关键词:虚拟仪器;振动测试;LabVIEW;单片机

Vibration Testing System Based on LabVIEW Signal Design Abstract : Virtual instrumentation is modern computer technology combined with the deep-seated instrument technology new concept instrument , in essence, the use of the computer monitor 's display traditional analog instrument control panel to output measurement results of various forms of expression , the use of powerful computer software functions the operation data for signal analysis and processing is completed for all test functions of a computer system apparatus . The design takes advantage of LabVIEW -based virtual instrument technology designed a vibration test systems, next-bit machine using AT89C52 microcontroller for data sampling , and to achieve data transmission signal via RS-232 serial communication with the PC , PC software development based on LabVIEW platform. Which has a signal acquisition, waveform display , data processing, data storage , signal parameter detection and other functions, with a simple, intuitive interface, applicability, and other characteristics. By design, the data can be displayed in time domain and frequency domain analysis. Ke ywords: Virtual Instrument, vibration test, LabVIEW, SCM

系统运维手册模版

运维手册模板 ******* 二O XX 年XX 月?广西 ******* 移动公 司

目录 1 引言 (2) 1.1 编写目的. (2) 1.2 项目背景. (2) 1.3 术语与定义. (2) 1.4 参考资料. (2) 2 系统说明. (2) 2.1 系统用途. (2) 2.2 安全保密. (2) 2.3 总体说明. (2) 2.4 程序说明. (2) 2.4.1 程序 1 的说明. (2) 2.4.2 程序 2 的说明. (3) 3 操作环境. (3) 3.1 设备 (3) 3.2 支持软件. (3) 3.3 数据库 (3) 3.3.1 总体特征. (3) 3.3.2 结构及详细说明. (3) 4 维护过程. (3) 4.1 约定 (3) 4.2 验证过程. (4) 4.3 出错及纠正方法. (4) 4.4 专门维护过程. (4) 4.5 专用维护程序. (4) 4.6 程序清单和流程图. (4)

1 引言 1.1 编写目的 【阐明编写手册的目的并指明读者对象。】 1.2 项目背景 【说明项目的提出者、开发者、用户和使用场所。】 1.3 术语与定义 【列出报告中所用到的专门术语的定义和缩写词的原意。】 1.4 参考资料 【列出有关资料的作者、标题、编号、发表日期、出版单位或资料来源,及保密级别,可包括:用户操作手册;与本项目有关的其他文档。】 2 系统说明 2.1 系统用途 【说明系统具备的功能,输入和输出。】 2.2 安全管理 【说明系统安全保密方面的考虑和用户权限的设置。】 2.3 总体说明 【说明系统的总体功能,对系统、子系统和作业做出综合性的介绍,并用图表的方式给出系统主要部分的内部关系。】 2.4 程序说明 【说明系统中每一程序、分程序的细节和特性。】 2.4.1 程序1 的说明 ? 功能:说明程序的功能。 ? 方法:说明实现方法。 ? 输入:说明程序的输入、媒体、运行数据记录、运行开始时使用的输入数据的类型和存放单元、与程序初始化有关的入口要求。 ? 处理:处理特点和目的,如:用图表说明程序的运行的逻辑流程;程序主要转移条件;对程序的约束条件;程序结束时的出口要求;与下一个程序的通信与联结(运行、控制);由该程序产生并茶馆处理程序段使用的输出数据类型和存放单元;程序运行存储

2020年(项目管理)系统运行维护手册项目

(项目管理)系统运行维护手册项目

XXX项目 系统运行维护手册安徽科大讯飞信息科技股份有限公司

修订文档历史记录

目录 1.前言 (3) 2.系统运行监控 (3) 2.1服务器运行状态监控 (3) 2.1.1监控内容 (3) 2.1.2监控要求 (3) 2.1.3监控产物 (4) 2.1.4操作说明 (4) 2.1.5邮件系统可用性验证 (8) 2.1.6SAN磁盘状态检查 (8) 2.2平台可用性检查 (9) 2.2.1监控内容 (9) 2.2.2监控要求 (10) 2.2.3监控产物 (10) 2.3补丁与病毒定义更新检查 (10) 2.3.1补丁检查与升级 (10) 2.3.2病毒检测及病毒定义更新检查 (10) 2.4垃圾邮件维护 (11) 2.4.1维护垃圾邮件地址列表 (11) 2.4.2定期清理垃圾邮件 (12) 2.5系统备份检查 (12) 2.6服务器硬件状态检查 (12)

3.1收集用户信息 (13) 3.2在AD中添加用户 (13) 3.3为用户开通邮箱 (15) 3.4为用户开通LCS功能 (16) 3.5为用户开通U SER S ERVICE服务 (17) 3.6在U SER S ERVICE中为用户配置角色 (18) 4.平台访问安全控制 (19) 5.平台系统开、关机 (19) 5.1系统关机 (19) 5.2系统开机 (20) 6.基础架构信息维护 (20) 7.系统运行维护报告 (21) 8.附件 (21) 8.1服务器监控范围 (21) 8.2系统运行监测记录表 (22) 8.3平台功能模块监测记录表 (24) 8.4服务器补丁升级检查表 (27) 8.5服务器病毒定义升级及病毒检查表 (28) 8.6服务器巡检记录表 (30) 8.7系统运行维护日报 (31)

振动测试系统

振动测试系统 1.主要功能 DASP V10振动测试系统包括信号采集和实时分析软硬件。DASP V10 是一套运行在Windows95/98/Me/NT/2000/Xp平台上的多通道信号采集和实时分析软件,通过和东方所的不同硬件配合使用,即可构成一个可进行多种动静态试验的试验室。DASP V10 软件既具有多类型视窗的多模块功能高度集成特性,具有操作便捷的特点。基于东方所在各种工程应用领域的长期经验,DASP-V10对各种功能模块重新进行整合,成为一套功能更加全面、操作更加便捷、界面更加美观、性能继续保持领先的动静态信号测试分析系统。DASP V10 软件的每一个模块中均包含了非常多的功能,各种功能可交错使用,在测试和分析的功能和性能上突破了以往信号分析仪的种种限制,与INV系列采集仪配合形成的系统的各项指标均可达到或超过国家高级仪器的标准。DASP V10 软件的所有测试分析结果都可以多种方式输出,包括图形的复制、存盘、打印,数据导出为TXT、CSV、Excel电子表格和Access数据库格式,并可轻松输出图文并茂的Word格式或者Html格式的分析报告。基于DASP V10 的平台上,还可以运行专业模态和动力学分析系统、虚拟仪器库、信号发生器以及针对声学、旋转机械、路桥土木、计量检定等行业的多种软件系统,满足各方面各层次的测试和分析需求。

3.隶属 (1)实验室:水机测控实验室(B01-205/207) (2)负责人:魏德华 一、ANSYS/CFD流体分析软件 1.主要功能 FLUENT、CFX是目前国际上比较流行的商用CFD软件包,国际市场占有率达70%。凡跟流体、热传递及化学反应等有关的领域均可使用。它具有丰富的物理模型、先进的数值方法以及强大的前后处理功能,在航空航天、汽车设计、石油天然气、涡轮机设计等方面都有着广泛应用,包括管路、渠道、流体机械、燃烧、环境分析、油气消散/聚积、喷射控制、多相流等方面的流动计算分析。 2.主要设备 3.隶属 (1)实验室:水机测控实验室(B01-205/207) (2)负责人:石祥钟

IT运维管理系统使用手册

IT运维管理系统使用手册

————————————————————————————————作者:————————————————————————————————日期:

IT运维管理系统 用户使用手册 大庆和光电子科技开发有限公司 二〇一六年十月

目录 1、基础信息 (3) 1.1项目信息 (3) 1.2项目检查项 (4) 1.3设备基础信息 (6) 2、日常巡检 (8) 2.1软件日巡检 (8) 2.2软件周巡检 (9) 2.3服务器系统巡检 (10) 2.4服务器硬件巡检 (10) 3、巡检查询 (11) 3.1软件日常巡检检查 (11) 3.2服务器巡检报告 (11) 4、运维资料管理 (12) 4.1系统问题管理 (12) 4.2项目资料管理 (15)

1、基础信息 1.1项目信息 主要录入各运维组所维护的项目信息,各运维组各自录入各自的项目信息。如下图所示 【新增】按钮:点击“新增”按钮,按要求添加项目信息,点击“确认保存”按钮即可。如图所示: 注:状态字段:有两个状态,分别是“正常”和“停用”。当状态是“正常”,则在软件日/周巡检中显示;当状态是“停用”,则在软件日/周巡检中不显示。 项目路径:填写该项目发布的位置,例如:D:\Publish

【编辑】按钮:点击“编辑”按钮,编辑已添加的项目信息,点击“确认保存”按钮即可。如图所示: 【删除】按钮:选中要删除项目前的复选框,点击“删除”按钮,确定要删除,点击“确认”按钮即可。如图所示: 1.2项目检查项 主要是录入各运维组巡检项目的检查项,各运维组录入各自的项目检查项信息,如下图所示

系统维护手册模板

湖南省地方税务局规费管理系统 维护手册 长沙海蝶计算机科技开发有限公司

一、适用范围 该手册适用于系统管理员及系统维护人员适用。 二、系统运行环境 2.1数据库环境 使用刀片3和刀片4这两块配置一模一样硬件来作为 ORACEL RAC 环境的两个物理节点。 在刀片系统配置两块物理千兆网卡作为数据库RAC实用网卡。 服务器信息: 网络配置: 其中公共IP的子网掩码: 安装软件: 数据库配置: grid 及 database 软件的安装操作全部都在 RAC1 服务器上进行,RAC2 服务器上的软件都是通过RAC1 通过局域网共享来完成安装。其数据库管理信息配置如下: 全局数据库名:orcl

数据库IP: 数据库别名: 所有账户统一管理口令: Asm专用的ASMSNNP口令: 数据库创建用户:密码: 网络拓扑图 2.2 Web环境 Web服务器为虚拟操作系统。 网络配置: 主机名: IP地址: IP的子网掩码: 默认网关: 安装软件: Weblogic配置: Weblogic管理用户:管理密码: 三、系统运维计划 3.1运维目标 地方税务局规费管理系统运维管理的目标是保证系统平台的正常、可靠、高速运行,保证对突发事

件、需求变更进行快速响应,保证规费管理系统的信息完整。 3.2运维内容 系统平台维护: 保证操作系统、数据库系统、中间件、其他支撑系统应用的软件系统及网络协议等安全性、可靠性和可用性而实施的维护与管理;及时排除系统故障;每月对系统平台进行一次巡检,及时消除故障隐患,保障系统的安全、稳定、持续运行。 应用系统管理和维护: 在系统维护过程中采取各种技术手段及时排除系统故障,保证系统及相应接口的安全性、可靠性和可用性。及时消除系统可能存在的安全隐患和威胁、根据需求更新或变更系统功能。 数据储存设施管理和维护: 为保证数据存储设施、如服务器设备、集群系统、存储网络及支撑数据存储设施运行的软件平台的安全性、可靠性和可用性,保证存储数据的安全。定期对系统的性能,确认数据存储的安全,及时消除故障隐患,保障系统安全、稳定、持续运行。 数据管理和维护: 数据管理是系统应用的核心。为保证数据存储、数据访问、数据通信、数据交换的安全,每月对数据的完整性、安全性、可靠性进行检查。 3.3 运维服务 在维护期间,具备灵活、多样的通信手段,提供5*8小时的响应服务,保证用户能及时得到技术支持。对于影响系统运行的故障,3小时内派人到现场解决,对于一般性故障,提供电话或E-Mail等方式解决;在维护期之外,由于软件原因引起的故障,由开发商提供升级解决; 技术支持热线为用户提供全面的技术服务,负责记录、解答用户的问题。 (1)公司不断地向用户传递最新的技术和产品,主动提供版本升级,并保证签定合同规定的期限内的系统维护及版本更新,同时向用户提供长期的技术咨询和服务。 (2)在系统的正常运行中出现的严重问题需现场解决的做到: ?公司做到1小时内响应,3小时内到现场服务。 ?其它情况根据距离远近尽快到现场服务。 (3)负责为用户到现场安装并调试公司的应用软件,直到系统能正常运行。

三振动系统固有频率的测量

实验三振动系统固有频率的测量 一、实验目的 1、了解和熟悉共振前后利萨如图形的变化规律和特点; 2、学习用“共振法”测试机械振动系统的固有频率(幅值判别法和相位判别法); 3、学习用“锤击法”测试机械振动系统的固有频率(传函判别法); 4、学习用“自由衰减振动波形自谱分析法”测试振动系统的固有频率(自谱分析法)。 二、实验装置框图

图3-1实验装置框图 三、实验原理 对于振动系统,经常要测定其固有频率,最常用的方法就是用简谐力激振,引起系统共振,从而找到系统的各阶固有频率。另一种方法是锤击法,用冲击力激振,通过输入的力信号和输出的响应信号进行传函分析,得到各阶固有频率。以下对这两种方法加以说明: 1、简谐力激振 简谐力作用下的强迫振动,其运动方程为: t F Kx x C x m e ωsin 0=++ 方程式的解由21X X +这两部分组成: ) sin cos (211t w C t w C e X D D t +=-ε 21D w w D -= 式中1C 、2C 常数由初始条件决定: t w A t w A X e e sin cos 212+= 其中 ( ) () 2 2 2 22 2 214e e e q A ω εω ω ωω+--= , () 22 222 242e e e q A ω εω ω ε ω+-= , m F q 0= 1X 代表阻尼自由振动基,2X 代表阻尼强迫振动项。 自由振动周期: D D T ωπ 2= 强迫振动项周期: e e T ωπ 2= 由于阻尼的存在,自由振动基随时间不断得衰减消失。最后,只剩下后两项,也就是通常讲的定常强动,即强迫振动部分: ( ) () () t q t q x e e e e e e e e ωω εω ω ε ωωω εω ω ωωsin 42cos 422 222 22 222 2 2+-+ +--= 通过变换可写成

振动信号检测系统设计1

(此文档为word格式,下载后您可任意编辑修改!) 信号检测综合训练 说明书 题目:振动信号检测系统设计 学院:电气工程与信息工程学院 班级:电子(2)班 姓名: 钱鹏鹏 指导老师:缑新科 2014.12.07

摘要 机械在运动时,由于旋转体的不平衡、负载的不均匀、结构刚度的各向异性、间隙、润滑不良、支撑松动等因素,总是伴随着各种振动。机械振动在大多情况下是有害的,振动往往会降低机器性能,破坏其正常工作,缩短使用寿命,甚至导致事故。机械振动还伴随着同频率的噪声,恶化环境,危害健康。另一方面,振动也被利用来完成有用工作,如运输、夯实、清洗、粉碎、脱水等。这时必须正确选择振动参数,充分发挥振动机械的性能。在现代企业管理制度中,除了对各种机械设备提出低振动和低噪声要求外,还需随时对机器的运行状况进行监测、分析、诊断,对工作环境进行控制。为了提高机械结构的抗振性能,有必要进行机械机构振动分析和振动设计,这些都离不开振动测试。 本文在此基础上设计了一种专用的振动信号检测系统,具有功耗低、体积小、精度高等优点。 信号检测的内容要求: 通过MCS-51系列单片机设计振动信号检测系统。要求如下: 1 振动信号的特点,选择合适的传感器,并设计相应的检测电路; 2 将设计完成的检测电路,通过软件防真验证; 3 主要设计指标:可测最大加速度:-5m/s~+5m/s;可测最大速度:-0.16m/s~+0.16m/s;可测最大位移:-5mm~+5mm;通频带:0.05Hz~35Hz;转换精度:8bit;采样频率:128Hz 4 利用LCD显示振动信号,有必要的键盘控制。 总体设计方案介绍:

运维手册

XX体检系统 维护手册修订记录 XX软件股份有限公司

目录 1概述 (3) 1.1系统结构 (3) 1.2数据库分布 (4) 2运维环境介绍 (5) 2.1服务器配置及端口互通关系 (5) 2.2开发运行环境 (6) 2.2.1数据库 (6) 2.2.2插件(软件) (6) 2.2.3系统运行所需JDK (7) 2.2.4网络 (7) 3基本维护 (8) 3.1业务软件安装 (8) 3.2新增功能页面 (8) 3.3配置文件参数配置 (8) 3.4数据库维护 (9) 4账户信息 (10) 4.1登录服务器 (10) 4.2数据库 (10) 4.3其他问题........................................... 错误!未定义书签。

关键词: 摘要:本手册对系统运行环境、主要配置文件、系统新数据录入方法等进行了介绍,说明了主要运维工作的处理,以及常见问题的处理。 1概述 1.1 系统结构 系统采用的结构描述 业务平台结构图

1.2 数据库分布 数据分布图 portal为门户系统数据库 bs_tjxt为体检系统数据库 bslis52为检验数据库 bs_tjxt_photo为影像数据库 1.3 数据接口 各系统之间的数据调用关系如下图所示: 数据调用关系图 1、体检-检验接口:体检系统登记人员信息,产生检验项目信息与检验条码后,将 这些信息插入bslis52数据库里的l_jytmxx表。检验系统得到检验项目的结果后,生成 结果视图vi_tj_result,体检系统的项目与该视图结果进行对照后获取检验结果。 2、体检-影像接口:

软件系统运维指导手册

系统日常维护指导手册

目录 1、目的 (4) 2、适用范围 (4) 3、服务器及数据库概述 (4) 3.1 服务器概述 (4) 3.2 数据库概述 (4) 4、系统服务程序的详细说明 (5) 4.1系统服务程序的构成 (5) 4.2 系统服务程序的启动、关闭及维护管理 (5) 4.2.1 dhcp主服务 (5) 4.2.1.1 dhcp主服务说明 (5) 4.2.1.2 dhcp启动、关闭及进程查看方法 (5) 4.2.1.3 配置说明 (6) 4.2.2 dhcp从服务 (8) 4.2.2.1 dhcp从服务说明 (8) 4.2.2.2 dhcp启动、关闭及进程查看方法 (9) 4.2.2.3 配置说明 (9) 4.2.3 web管理模块 (12) 4.2.3.1 web管理模块中主要目录说明 (12) 4.2.5.2 web管理模块中各程序说明 (12) 4.2.5.3 web站点启动、关闭及进程查看方法 (12) 4.2.5.4 web日志说明 (12) 4.2.5.5 日常维护 (13) 5、服务器硬件维护(略) (13) 6、linux系统的日常维护 (13) 6.1 定期检查磁盘空间 (13) 6.2 使用top工具监视cpu及内存的使用率 (14) 6.3 定期查看root邮件 (14) 6.4 定期查看系统日志 (15) 7、备份策略 (15) 7.1 备份方式 (15) 7.2 备份计划 (15) 7.3 常见故障恢复 (15) 7.3.1 实例故障 (16) 7.3.2 介质故障 (16) 9、数据库的日常维护 (18) 9.1 检查数据库的基本状况 (18)

相关文档
最新文档