omron光电式液位开关
OMRON欧姆龙光电开关型大全

O M R O N欧姆龙光电开关型大全The latest revision on November 22, 2020OMRON欧姆龙光电开关(1号整经机)E3JK-DS30M1扩散反射型检测距离30CMOMRON欧姆龙光电开关1.E3JK-R2M1回归反射型检测距离2M2.E3JK-R4M1回归反射型检测距离4M3.E3JK-R4M2回归反射型检测距离4M4. E3JK-5M1对射型检测距离5M5.E3JK-5M2对射型检测距离5M6.E3JK-DS30M1扩散反射型检测距离30CM7. E3JM-10M4T定时型对射检测距离10M8.E3JM-10M4对射检测距离10M9.E3JM-10M4-G对射,检测距10M10. E3JM-DS70M4扩散反射型检测距离70CM11.E3JM-DS70M4-G扩散反射型检测70CM12. E3JM-R4M4T-G定时型回归反射检测距离4M13.E3JM-R4M4-G回归反射检测距离4M14.OMRON欧姆龙光电开关E3F3-D11φ18扩散反射型检测距离10CM/DC10-30V15.E3F3-D12φ18扩散反射型检测距离30CM/DC10-30V16. E3F3-R61φ18回归反射检测距2M/DC10-30V17.E3F3-T61φ18对射型检测距离10M/DC10-30V18. E3S-2E4对射型检测距离2M/DC10-30V19.E3S-2E4对射型检测距离5M/DC10-30V20.E3S-AD11扩散反射型检测距离20CM/DC10-30V21.E3S-AD61扩散反射型/DC10-30V22. E3S-AR61回归反射DC10-30V23.E3S-AR11回归反射检测距离2M/DC10-30V24. E3S-AT11对射型检测距离7M/DC10-30V25.E3S-AT61对射型/DC10-30V26. E3S-CL22M E3S-DS10E4扩散反射型检测距10CM/DC10-30V27.E3S-DS10E41扩散反射型检测距离10CM/DC10-30V28.E3S-GS1E4槽型检测距离10MM/DC10-30V29.E3S-GS3E4槽型检测距离30M/DC10-30V E3S-GS3B4槽型检测距离30M/DC10-30V30.E3R-5E4对射型检测距离5M/DC10-30V31. E3R-DS30E4扩散反射型检测距离30CM/DC10-30V32.E3R-R2E4回归反射型检测距离2M/DC10-30V33.OMRON欧姆龙光电开关E3Z-D61扩散反射型检测距离100M/DC10-30V34.E3Z-D62扩散反射型检测距离100M/DC10-30V35.E3Z-D81扩散反射型检测距离100M/DC10-30V36.E3Z-D82扩散反射型检测距离100M/DC10-30V37.E3Z-R61回归反射型检测距离4M/DC10-30V38.E3Z-R82回归反射型检测距离4M/DC10-30V39. E3Z-T61对射型检测距离15M/DC10-30V40.OMRON欧姆龙光纤放大器E3X-A11通用型NPN输出DC10-30V41.E3X-NA11通用型NPN输出DC10-30V42. E3X-NA41通用型PNP输出DC10-30V43.E3X-NM11通用型NPN输出DC10-30V,4路输出。
OMRON光电传感器操作手册

݊Ёӏϔ䬂 ᣝV
᳝Ꮉӊ⢊ᗕϟ
Ꮉ 7(&+ ----
݊Ёӏϔ䬂 ᣝV
Ā----ā䮾⚕
Ā----ā䮾⚕
83 581 '2:1
㟇581
᮴Ꮉӊ⢊ᗕϟ
5)&+ 䯜ؐ
݊Ёӏϔ䬂 ᣝV
7+58
䯜ؐ
ĀᏆ䆒ᅮདⱘ䯜ؐā䮾⚕
ĀᏆ䆒ᅮདⱘ䯜ؐā䮾⚕
ফܝ䞣
䯜ؐ
ফܝ䞣
䯜ؐ
䆒ᅮ㒧ᴳৢˈ䖨ಲࠄ ᪡ࠡⱘᰒ冫
406
᳔ᮄѻક䌘᭭䇋ⱏᔩ
᪡㆛⬉ܝӴᛳ఼
ܝ ⬉ Ӵ ᛳ ఼
⊼
ৠᯊᣝV
䆒ᅮࡼᓣ
ৃҹ䗮䖛ߛᤶᓔ݇䆒ᅮࡼᓣDŽ ࡼᓣ ᪡ /g21 'g21
/
ߎॖᯊⱘ䆒ᅮ
>䖨ಲ߱ྟܝ䞣ᯊ@
'2:1 02'(
ܹܝᯊ21 䙂ܝᯊ21
⊼ᣝ02'(䬂ৢ䇋ゟेᣝ'2:1䬂DŽ
显示 主数字显示
/2&
辅数字显示
21
备注 可锁定按键操作,以防止误操 作。 →413页 “6.便利功能” 可将产品恢复至出厂设定状态。 →413页 “6.便利功能”
UP
MODE
ᡔᴃ㆛ ᪡㆛
6(7
UP DOWN
初始复位
,1,7
<(6"
* E3X-MDA□/E3X-DA□TW-S/E3X-DA□AT-S除外。 这些机型没有功率调谐指示灯,但备有动作指示灯(ch2)。
䗮䖛ᬍ䆒ᅮݙᆍDŽ
ࡳ㛑ৡ鹵
ࡼᓣ Ẕ⌟ࡳ㛑
䆒ᅮݙᆍ ᰒ冫
ܹܝᯊ21˖ǃ䙂ܝᯊ21˖ ᳔ᖿ˖ǃ催䗳˖ǃᷛ˖ޚǃ催㊒ᑺ˖ǃ ᖂߚࡼ˖ ҙ催ࡳ㛑ൟ
欧姆龙元器件产品基础-61F.

基本型 如61F-G
底座型 如61F-GP-N
对应不同液位控制要求的61F型号
自动给/排水
带有水泵空转防止 或异常缺水报警的 自动给水系统 带有异常满水的自 动给水或排水系统 带有满水/缺水报警 的自动给水或排水
61F-GN/61F-GP/61F-GP-N(8)
61F-G1N/61F-G1/61F-G1P
61F-G2N/61F-G2/61F-G2P
61F-G3N/61F-G3
带有给水源上下限 指示/防水泵空转/ 排水水槽满水/缺水 报警的自动给水系统
仅做水位指示和报警
61F-G4N/61F-G4
61F-IN/61F-I/61F-IP
液位开关61F
液位开关的原理
液位开关是利用导电液体的导电性构成回路,产生一定电流并驱 动继电器进行输出的装置。 继电器 触点 电流
继电器
~
电源
电极棒 导电液体
液位开关广泛应用于 楼宇自动化中水箱的液位控 制、液体包装设备原料供应 罐的液位控制和锅炉液位控 制等。 电极棒
61F系列液位开关特点
-经济型高可靠性的电极式液位控制器 -有底座型、插入型、远距离型及高/低感度型(0-40㏀)等各种规 格,使用于不同场合、不同导电率液体的控制 -取代传统浮球式液位开关 -用于水泵控制系统中,可广泛应用于建筑、农用水、污水处理等各行 业的自动给排水系统中
61F的结构
61F控制器本体
电极保持器
电ห้องสมุดไป่ตู้棒
61F液位控制系统
LED指示灯
配置61F液位控制系统时应考虑以下 因素 61F控制器本体 61F控制器本体的安装方式 液位控制要求 使用环境和液体种类 电极棒的安装方式 液体化学特性及电极棒长度
欧姆龙光电开关说明书

欧姆龙光电开关说明书1. 引言欧姆龙光电开关是一种利用光电传感器技术实现的开关设备,通过检测光线的变化来判断是否触发开关动作。
本说明书将详细介绍欧姆龙光电开关的技术原理、使用方法、注意事项以及维护保养等内容,以帮助用户合理、安全地使用该设备。
2. 技术原理欧姆龙光电开关采用了光电传感器技术,在光电传感器中,包含了一对光源和光敏元件。
当遮挡物体经过检测区域时,光敏元件将接收到的光信号发生变化,从而触发开关动作。
光电开关通常有两种工作方式:逻辑输出和模拟输出,具体的输出信号可以根据用户需求进行设置。
3. 使用方法a)安装根据实际需求,将光电开关安装到需要检测的位置上,确保光敏元件可以正常接收到被检测物体通过的光信号。
注意避免外部光源对光敏元件产生干扰,可以通过合理选择安装位置和使用遮光罩等方式来减少干扰。
b)连接将光电开关与电路连接,确保电路连接正确且稳定。
通常光电开关需要使用直流电源进行供电,电压范围根据具体型号来确定。
c)设置根据实际应用需求,设置光电开关的工作方式、触发灵敏度等参数。
欧姆龙光电开关通常提供了相应的参数调节装置,用户可以根据需要进行调整。
d)测试完成安装、连接和设置后,进行测试以确保光电开关正常工作。
可以通过手动触发被检测物体通过检测区域,观察开关的触发情况,根据实际需求进行调整。
4. 注意事项a)使用过程中请确保电源电压符合设备要求,避免超过额定电压范围。
b)在使用过程中请避免将光电开关安装在高温、潮湿等有害环境中,以免影响设备的正常工作。
c)避免遮挡光敏元件,在使用过程中请确保光敏元件处于正常工作状态,避免被阻挡物体遮挡。
d)避免外部光源干扰,在安装过程中请注意避免强光直射到光敏元件上,可以使用遮光罩等方式来减少光源干扰。
e)检查设备连接是否牢固,确保所有连接处都紧固可靠,避免松动引起的工作异常。
f)如设备出现故障,请及时联系专业维修人员进行处理,避免私自拆解修理。
5. 维护保养a)定期清洁光敏元件,可以使用干净的棉签轻轻擦拭。
欧姆龙液位继电器61f-gp-n工作原理

欧姆龙液位继电器61f-gp-n工作原理欧姆龙液位继电器61F-GP-N是一种常用于液位控制的电器设备,它能够通过测量液体的高度来实现液位控制功能。
本文将从工作原理的角度来介绍欧姆龙液位继电器61F-GP-N的工作原理。
欧姆龙液位继电器61F-GP-N采用了浮球测量原理。
它的工作原理是基于浮球在液体中的浮力变化来实现液位的检测和控制。
继电器内部有一个浮球,当液位升高时,浮球会随着液面的上升而上浮;当液位下降时,浮球则会向下沉。
利用浮球的上浮和下沉来实现液位的控制。
具体来说,欧姆龙液位继电器61F-GP-N内部有一个浮球和一个浮球杆。
浮球杆通过机械连接与继电器的开关接点相连。
当液位上升时,浮球随着液面的上升而上浮,浮球杆也会随之向上移动,最终触碰到继电器的开关接点,使其闭合。
当开关接点闭合时,继电器会输出一个信号,用于控制其他设备的开启或关闭。
同样地,当液位下降时,浮球会随着液面的下降而下沉,浮球杆也会向下移动,使开关接点断开。
当开关接点断开时,继电器停止输出信号,控制设备也会相应地进行开启或关闭的操作。
欧姆龙液位继电器61F-GP-N具有高度可调的浮球杆,通过调整浮球杆的高度,可以实现不同液位的检测和控制。
此外,该继电器还具有可调的感受灵敏度,可以根据实际需求来调整继电器的触发灵敏度。
欧姆龙液位继电器61F-GP-N具有很多应用场景,比如水箱、水池、水塔等液位控制领域。
它可以实现液位的监测和控制,以确保液位在合适的范围内。
同时,该继电器还具有防水、防尘和耐腐蚀的特性,适用于各种恶劣环境。
总结一下,欧姆龙液位继电器61F-GP-N采用了浮球测量原理,通过浮球在液体中的浮力变化来实现液位的检测和控制。
它具有高度可调的浮球杆和可调的感受灵敏度,适用于各种液位控制场景。
欧姆龙液位继电器61F-GP-N的工作原理简单可靠,为液位控制提供了有效的解决方案。
OMRON光电开关调节与设定

«电工技术» 2002年1期 OMRON 光电传感器 调节与设定重庆大学电气工程学院 廖常初[摘要]以OMRON的光电传感器为例,介绍了光电传感器常见的调节和设定方法。
关键词 传感器 光电 调节为了保证光电传感器功能的实现,降低调试难度,减少调试时间,现代光电传感器设置了很多调节功能,给使用者带来了极大的方便。
1.光轴的调节OMRON公司比较典型的对射式光纤传感器的放大器E3X-NT21如图1所示,图2使它的输出电路。
调节光轴时,将模式(MODE)开关置于TEACH(示教)位置,可执行特殊闪动功能。
如发光光纤与受光光纤的尖端未对齐,或光轴未对正,使受光亮度低于峰值的10%时,投光光纤尖端的指示灯不断闪动,且蜂鸣器发出响声。
将光纤光轴对证对齐后,该指示灯停止闪动,处于亮灯状态,调节结束。
在光轴矫正前、校正中按下示教按钮,特殊闪动功能消失。
2.最大灵敏度设定有示教功能的传感器首先应调节最大灵敏度。
将发光光纤和受光光纤放在检出距离之内。
将放大器上的模式设定开关切换到TEACH一侧,调整对齐发光光纤和受光光纤的光轴。
按下示教按钮3s以上,示教指示灯三红变绿。
内部的蜂鸣器在红灯时响一声,绿灯亮时连续响。
松开示教按钮后,蜂鸣器停止发声。
将模式切换开关切换到RUN位置,最大灵敏度设定结束。
示教指示灯熄灭。
设定最大灵敏度时,与光纤间的距离,是入光还是遮光无关。
用动作模式切换开关设定希望的逻辑输出。
若开光置于L.ON(Light ON),受光时输出为ON,若置于D.ON( Dark ON),遮光时输出为ON。
3.无工作示教示教(TEACH)功能用来检测背景光的强度或光泽度,以消除背景光的影响,使传感器能正确分辨出被检测物的有无,或分辨光量、光泽的变化。
无工件示教时,将发光光纤和受光光纤放在检出距离之内,放大器上的模式设定开关切换到TEACH一侧,调整对齐发光光纤和受光光纤的光轴。
无被检测物时按下示教按钮0.5~2.5s,示教指示灯红灯亮,内部的蜂鸣器响一声。
欧姆龙光电开关工作原理

欧姆龙光电开关工作原理
欧姆龙光电开关是一种利用光电效应实现开关功能的设备。
它主要由光电转换器、信号处理电路和输出继电器组成。
光电转换器是光电开关的核心部件,它通常由发光二极管(LED)和光敏三极管(光敏二极管)构成。
LED作为发光源,发出红外或可见光信号。
光敏三极管则接收LED发出的光信号,并根据光信号的变化产生相应的电流。
在工作时,光电开关会发出一束光束,光束被遮挡或反射时,光信号发生变化,进而引起光敏三极管输出电流的变化。
这个电流信号经过信号处理电路的放大和滤波处理后,将被送入输出继电器。
输出继电器是光电开关的输出部分,它根据信号处理电路输出的电流信号,进行电流的开关操作。
当光敏三极管输出电流的变化达到一定程度时,输出继电器就会被触发,从而实现开关的操作。
欧姆龙光电开关具有高度的稳定性和可靠性,并且由于使用光信号进行操作,不受环境中尘埃、油污等物质的影响,适用于各种工业自动化控制系统中的位置检测、物体计数、自动控制等方面的应用。
总的来说,欧姆龙光电开关的工作原理是利用光电转换器将光信号转化为电流信号,通过信号处理电路放大和滤波后送入输
出继电器进行开关操作。
这种光电开关具有稳定可靠的特点,适用于工业自动化控制系统中的各种应用场景。
omron - ee-sx1088 光电开关 (透射式) 说明书

52EE-SX1088 Photomicrosensor (Transmissive)■DimensionsNote:All units are in millimeters unless otherwise indicated.■Features•General-purpose model with a 3.4-mm-wide slot.•Mounts to PCBs or connects to connectors.•High resolution with a 0.5-mm-wide aperture.•OMRON’s XK8-series Connectors can be connected without sol-dering. Contact your OMRON representative for information on obtaining XK8-series Connectors.■Absolute Maximum Ratings (Ta =25°C)Note:1.Refer to the temperature rating chart if the ambient temper-ature exceeds 25°C.2.The pulse width is 10 μs maximum with a frequency of 100Hz.plete soldering within 10 seconds.■Electrical and Optical Characteristics (Ta = 25°C)Internal CircuitCETerminal No. Name A Anode K Cathode C Collector EEmitterDimensions Tolerance 3 mm max.±0.33 < mm ≤ 6 ±0.3756 < mm ≤ 10 ±0.4510 < mm ≤ 18 ±0.5518 < mm ≤ 30±0.65Two, R1Two, 3.2±0.2 dia. holesTwo, C2Four, C0.3Four, 0.25Four, 0.5(Optical axis)Cross section BBCross section AA25±0.219±0.150.5±0.16.5±0.10.5±0.18.4±0.13±0.45±0.26±0.22.5±0.17.2±0.210±0.2Unless otherwise specified, the tolerances are as shown below.ItemSymbol Rated value Emitter Forward current I F 50 mA(see note 1)Pulse forward cur-rentI FP 1 A(see note 2)Reverse voltageV R 4 V DetectorCollector–Emitter voltageV CEO 30 V Emitter–Collector voltageV ECO ---Collector current I C 20 mA Collector dissipa-tionP C 100 mW (see note 1)Ambient tem-peratureOperating Topr –25°C to 85°C StorageTstg –30°C to 100°C Soldering temperatureTsol260°C(see note 3)ItemSymbolValueConditionEmitterForward voltage V F 1.2 V typ., 1.5 V max.I F = 30 mA Reverse currentI R 0.01 μA typ., 10 μA max.V R = 4 V Peak emission wavelengthλP 940 nm typ.I F = 20 mADetectorLight current I L 0.5 mA min., 14 mA max.I F = 20 mA, V CE = 10 V Dark current I D 2 nA typ., 200 nA max.V CE = 10 V, 0 l x Leakage currentI LEAK ------Collector–Emitter saturated volt-ageV CE (sat)0.15 V typ., 0.4 V max.I F = 20 mA, I L = 0.1 mA Peak spectral sensitivity wave-lengthλP 850 nm typ.V CE = 10 VRising time tr 4 μs typ.V CC = 5 V, R L = 100 Ω, I L = 5 mA Falling timetf4 μs typ.V CC = 5 V, R L = 100 Ω, I L = 5 mABe sure to read Precautions on page 25.EE-SX1088 Photomicrosensor (Transmissive) 53■Engineering DataDissipation Temperature RatingVoltage Characteristics (Typical)Characteristics (Typical)Light Current vs. Collector −Emitter Voltage Characteristics (Typical)Dark Current vs. Ambient Temperature Characteristics (Typical)Distance d (mm)Input OutputInputOutput90 %10 %(Center of optical axis)Sensing Position Characteristics (Typical)Response Time Measurement CircuitAmbient temperature T a (°C)C o l l e c t o r d i s s i p a t i o n P C (m W )Forward voltage V F (V)Forward current I F (mA)L i g h t c u r r e n t I L (m A )Collector −Emitter voltage V CE (V)L i g h t c u r r e n t I L (m A )Ambient temperature Ta (°C)Load resistance R L (k Ω)I F P CT a = −30°C T a = 25°C T a = 70°CT a = 25°C V CE = 10 VI F = 40 mA I F = 30 mA I F = 20 mA I F = 10 mAT a = 25°CV CE = 10 V 0 l xI F = 20 mA V CE = 5 VI F = 20 mA V CE = 10 V T a = 25°CV CC = 5 V T a = 25°CR e s p o n s e t i m e t r , t f (μs )R e l a t i v e l i g h t c u r r e n t I L (%)D a r k c u r r e n t I D (n A )I F = 50 mA Ambient temperature Ta (°C)Relative Light Current vs. Ambi-ent Temperature Characteristics (Typical)Response Time vs. Load Resist-ance Characteristics (Typical)Distance d (mm)Sensing Position Characteristics (Typical)R e l a t i v e l i g h t c u r r e n t I L (%)100806040200−1.5−2.0−1.0−0.500.51.01.52.0120dI F = 20 mA V CE = 10 V T a = 25°C(C e n t e r o f o p t i c a l a x i s )。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
DC12~24V 脉动10%以下(DC10.8~30V)
消耗电流
12mA以下
控制输出
开关容量 残留电压
100mA以下 1V以下 (负载电流:100mA、导线长:2m时)
检测液位
凹记号位置 详情请参照→1428页 「灵敏度调整 (操作编)」参照
显示灯
检测位置 (橙色)
周围环境温度
使用时:0~+55℃、保存时:-10~+65℃ (不结冰·结露)
●其他
体的电容率低的时候,从
电源投入时到安定有20分钟,检测水平将上升到2~3mm,应
注意。
Ӵᛳ఼ᣛफ
(单位:mm) ᷅ൟ
ᅝ㺙ᄨ 1.5
㾦ൟ
ᬒ఼ߚ行 Ё㒻ൟ
䴭⬉ᆍ䞣ൟ
Ẕ⌟ᰒ冫♃˄˅
݊Ҫ
CAD᭄
E2K-L26MC1
43 41 33
45
Ẕ⌟䴶
1 3.5
⑶在管道内壁的高粘度的液体膜及大量的泡沫残留,或管道内外壁污渍的粘着·堆积等时
䖥Ӵᛳ఼
Ӵᛳ఼ᣛफ ᷅ൟ 㾦ൟ ᬒ఼ߚ行 Ё㒻ൟ 䴭⬉ᆍ䞣ൟ ݊Ҫ ೈ䆒 ҟ㒡
特性数据 (代表例)
检测液位的温度的影响
E2K-L13MC1
Ẕ ⌟6 ⎆ ԡ ⱘ4 ব
ㅵ䘧Ⳉᕘ˖φ11ǃ⎆ԧ˖㒃∈ ㅵ䘧Ⳉᕘ˖φ11ǃ⎆ԧ˖Ⲥ∈ ㅵ䘧Ⳉᕘ˖φ8ǃ⎆ԧ˖㒃∈ ㅵ䘧Ⳉᕘ˖φ8ǃ⎆ԧ˖Ⲥ∈
ҟ㒡
ㅵ䘧
A
LJᇍ䴶Lj
B
C
LJऩ䴶Lj
周围物体的影响
型号
尺寸
A
E2K-L13MC1 25
E2K-C E2K-L26MC1
LJϸ䴶Lj
(单位:mm)
B
C
5
45
0
40
E2K-X
相互干涉 E2K-F 直列,并列,对向设置的情况下,应保持以下范围以下的距 E2K-L 离。
E2KQ-X
E2J
Ӵᛳ఼Џԧ Ẕ⌟ᰒ冫♃
♉ᬣᑺ 䇗ᭈ䪂
⎆ԡ
䆒ᅮԡ㕂 ˄ߍ䆄ো˅
ᤚ㒥ᏺ
ℶ⒥ㅵ
LJջ㾚Lj
LJℷ㾚Lj
ㅵ䘧
Ӵᛳ఼Џԧ
ᤚ㒥ᏺ
ℶ⒥ㅵ
LJ׃㾚Lj
D
LJⳈ߫䆒㕂Lj
E
LJᑊ߫䆒㕂Lj
)
LJᇒ䀁㕂Lj
934
E2K-L
●配线时 关于电源 ·负载和传感器分别接电源时,必须先投入传感器的电源。 ·使用市贩的开关调整器时,由于开关噪音会有错误动作发
Ӵᛳ఼ᣛफ
᷅ൟ
㾦ൟ
详情请参阅934页的 「请正确使用」。
ᬒ఼ߚ行
Ё㒻ൟ 种类
䴭⬉ᆍ䞣ൟ
检测方式
适用管道直径
݊Ҫ
ೈ䆒 ҟ㒡 静电容量方式
φ8~11mm
形状
输出型号/动作模式
NPN集电极开路输出 NO
φ12~26mm
型号 E2K-L13MC1
E2K-L26MC1
E2K-C E2K-X E2K-F E2K-L E2KQ-X
50MΩ以上(DC500V兆欧表)所有充电部和外壳间
耐电压
AC500V 50/60Hz 1min 充电部包括和外壳间
振动 (耐久)
10~55Hz 上下振幅1.5mm X、 Y、 Z各方向 2h
冲击 (耐久)
500m/s2 X、 Y、 Z各方向 3次
保护结构
IEC规格 IP66
接连方式
导线引出式 (标准导线长2m)
-2
50 60 ⏽ᑺ(ć)
-4 -6
E2K-C E2K-X E2K-F E2K-L E2KQ-X E2J
933
E2K-L
输入输出段回路图
动作模式
型号
䖥Ӵᛳ఼
NO
E2K-L13MC1 E2K-L26MC1
时间图
᳝ ⎆ԡ
᮴
䋳䕑
ࡼ
˄㻤ˉ咥䯈˅ᘶ
Ẕ⌟ᰒ冫♃҂♃
˄˅
♁♃
Џಲ䏃
质量 (捆包状态)
约70g
材质
外壳、套 电线夹子
耐热ABS NBR
附属品
捆绑带2根、防滑管4个、使用说明书
*1. 以下情况下,会出现无法测定的现象,必须在设置的装置上进行检测性能的确认后再使用。 ⑴液体的电容率或导电率很低时 ⑵液体容量少,或由于管道尺寸的细直径·壁厚等,使液位的变化的相应容量变化很小时
6.5 ล᭭㒱㓬ᔶᇐ㒓 φ2.9ǃ3㢃 ˄ᇐԧ䴶鳥˖0.14mm2ǃ㒱㓬Ⳉᕘ˖φ0.9mm˅
ᷛޚ2m
6 4.5
♉ᬣᑺ䇗ᭈ䪂
ೈ䆒 ҟ㒡
6
20 5
R13 R17.5
CAD᭄
34 32 24
33
ᅝ㺙ᄨ
6 4.5
11
1.5
Ẕ⌟ᰒ冫♃˄˅
♉ᬣᑺ䇗ᭈ䪂
2 3
1
Ẕ⌟䴶 3.5
6.5
6
ล᭭㒱㓬ᔶᇐ㒓 φ2.9ǃ3㢃 ˄ᇐԧ䴶鳥˖0.14mm2ǃ㒱㓬Ⳉᕘ˖φ0.9mm˅
生。框架接地端子及接地端子应该地后使用。
外形尺寸
E2K-L13MC1
20 5
R6.5 R17.5
24 11
●使用环境
关于周围环境
·本商品为耐水结构,但,由于是静电容量型,应避免在有直接
液体 (水或切削油等)的环境下的使用。
·即使是在使用温度范围内,如果有急剧的温度的升降,也会
缩短其寿命,所以,必须注意。
周围物体的影响 ݊Ҫ 周围物体为金属等导体时,性能会受影响,设定时必须保持下
图以上的距离。 ೈ䆒
ㅵ䘧
Ӵᛳ఼Џԧ
型号
尺寸
D*
E
F
E2K-L13MC1
25
10
10
E2K-L26MC1
30
*但是,通过调整下面的传感器,有时也会发生上面传感器的检测水平的变动, 必须要先调整下面的传感器。
●配线时 关于安装 用附属的捆绑带2个和止滑管4个 (1个捆绑带使用2个),按照 下图确切安装好。 此时,管道要沿着传感器检测面的中心线,紧密安装。
输出回路
㻤 +V
䋳䕑 咥 ˆ
㪱 0V
ˆ᳔100mA˄䋳䕑⬉⌕˅
请正确使用
Ӵᛳ఼ᣛफ 详情请参见共通注意事项(→1337页),有关订货时的须知请参见(→F-4页)。
警告
᷅ൟ 本产品不可以作为人体保护检测使用。
相互干涉
(单位:mm)
㾦ൟ
ᬒ఼ߚ行 Ё㒻ൟ
使用注意事项
请不要在超过额定的使用范围和环境下使用。 䴭⬉ᆍ䞣ൟ ●设计时
液位传感器
E2K-L
相关信息 技术指南 (技术篇) ...........· 1332
技术指南 (操作篇) ........... 1428
对应多种管道直径。 是静电容量方式,不受管道、液体颜色 䖥Ӵᛳ఼ 的影响
■安装于导管上。 ■φ8~11mm、 φ12~26mm和多种管道直径。 ■放大器内置型,省空间安装。
࣪嗻
嗼 mm 2
0 -10 0
10 20 30 40
-2
50 60 ⏽ᑺ(ć)
-4 -6
E2K-L26MC1
Ẕ ⌟6 ⎆ ԡ ⱘ4 ব
ㅵ䘧Ⳉᕘ˖φ26ǃ⎆ԧ˖㒃∈ ㅵ䘧Ⳉᕘ˖φ26ǃ⎆ԧ˖Ⲥ∈ ㅵ䘧Ⳉᕘ˖φ12ǃ⎆ԧ˖㒃∈ ㅵ䘧Ⳉᕘ˖φ12ǃ⎆ԧ˖Ⲥ∈
࣪嗻
嗼 mm 2
0
10
0 -10
20 30 40
周围环境湿度
使用时·保存时:各25~85%RH (不结露)
温度的影响
0~+55℃的温度范围内、在+23℃时的检测水平的±4mm (以纯水及20%的盐水) (但、 E2K-L13MC1的管道直径φ8的纯水时,±6mm)
电源的影响
额定电源电压±10%的范围内,额定电源电压时的检测水平的±0.5mm
绝缘抗阻
ᷛޚ2m
E2K-C E2K-X E2K-F E2K-L E2KQ-X E2J
935
E2J
932
额定值/性能
E2K-L
项目
型号
E2K-L13MC1
E2K-L26MC1
材质
非金属
适用管道
尺寸
外径 壁厚
φ8~11mm 1mm以下
φ12~26mm 1.5mm以下
检测物体
液体 *1
重复距离精度
±0.2mm以下
应差
为不同管的尺寸、溶液变 动提供参考值
0.6~5mm
0.3~3mm
电源电压 (使用电压)