STN300箱变保护测控装置说明书

合集下载

ST300使用说明书

ST300使用说明书

网络报警模块ST300使用说明书2013年3月目录目录..............................................................................................................................................2简介................................................................................................................................................3安装使用.........................................................................................................................................4外型尺寸.................................................................................................................................4电气接线.................................................................................................................................5端子定义及指示.............................................................................................................5LED灯指示............................................................................................................................5出厂默认及系统,主机编程使用注意事项.........................................................................5保养、维护.............................................................................................................................6附录:............................................................................................................................................7研发定制说明.................................................................................................................................8简介ST300是配合EL(顶峰)ST2000/2008报警主机使用的网络接入报警模块,该模块可通过TCP/IP协议或RS232串口将报警主机的键盘状态信息上传给接警中心,并且可以在接警中心模拟键盘发送键盘命令,实现对ST2000/2008主机报警主机进行撤布防、防区旁路、防区旁路恢复等主机命令操作。

DN300A系列数字式保护测控装置技术使用说明书

DN300A系列数字式保护测控装置技术使用说明书
1.1 装置简介...............................................................................................................................1 1.2 装置特点...............................................................................................................................1 1.3 结构与安装...........................................................................................................................1 1.4 装置背板端子图...................................................................................................................2 1.5 操作回路和出口原理示意图...............................................................................................2
5 DN322A 变压器后备保护装置 .............................................................................................19
5.1 装置简介.............................................................................................................................19 5.2 主要技术指标.....................................................................................................................19 5.3 保护原理.............................................................................................................................19 5.4 DN322A 定值及整定说明 .................................................................................................22 5.5 DN322A 信息一览表 .........................................................................................................23 5.6 DN322A 装置背板端子定义图 .........................................................................................24

箱变使用说明书

箱变使用说明书

箱变使用说明书(总4页) -CAL-FENGHAI.-(YICAI)-Company One1-CAL-本页仅作为文档封面,使用请直接删除箱变、开闭所操作维护说明说一、箱变、开闭所操作规程1、10kV、500kVA以上箱变、开闭所使用单位必须配备变电所专职电工。

电气工作人员必须身体健康,并具备必要的电气知识,取得电工证后方可上岗。

2、箱变安装后,运行、维护、操作、事故处理、交接与事故后的试验、预防性实验、保护校验等均由用户负责。

3、用户不准改变箱变原结构,否则将失去保修资格。

4、高压操作要由电气负责人签发操作票,并做好组织与技术安全措施。

5、高压倒闸操作必须由两人进行,带绝缘手套。

为保证安全每天定期进行巡回检查,单人巡视时不得进行任何操作,雷雨天巡视应穿绝缘靴。

6、严禁随意打开高压柜、电缆柜、需要打开时必须确认柜内带电部分已无电压。

7、安全技术措施⑴停电按规定断开各负荷开关及检修段上级负荷开关。

⑵验电使用相应电压等级验电器在停电设备进出线地侧进行验电,确认已无电压。

⑶放电使用符合规定的接地线进行各相放电。

接地线,各相短路并接地。

在一经合闸就可送电到检修点的开关上悬挂“禁止合闸,有人工作”标示牌。

8、各开关操作顺序为:(以开关说明书或开关上标示牌说明为准)⑴送电:(高压负荷开关:FN12-12为例):关闭柜门,转动框门门锁扣住柜门。

将操作杆插入接地开关操作孔内。

按标示转动至接地开关分闸,这时柜门应锁住不能开。

将操作杆插入负荷开关操作孔内。

按标示转动至负荷开关合闸,这时可听见变压器有轻微响声,说明高压已送电。

⑵停电将操作杆插入负荷开关操作孔内,按标示转动至负荷开关分闸。

观察开关隔离断口以分开,确认负荷开关断开后,系统已无电压。

将操作杆插入接地开关操作孔内按标示转动至接地开关合闸。

注意这时负荷开关进线端仍有高压电,如需进入高压开关柜内仍需进线电缆停电。

⑶本箱变低压配电系统接地制式为:TN-C接地系统。

NDX300系列数字式线路保护装置说明书

NDX300系列数字式线路保护装置说明书
Nhomakorabea目
1

装置简介............................................................................................................................................1 1.1 适用范围.....................................................................................................................................1 1.2 保护功能配置一览表 ...................................................................................................................1 1.3 产品特点.....................................................................................................................................2 2 技术参数..............................................................................................................................................4 2.1 环境参数 .............................................................

TDR935系列变压器保护装置技术说明书V200Build0422-2008

TDR935系列变压器保护装置技术说明书V200Build0422-2008

TDR935系列变压器保护装置技术说明书南京钛能电气研究所文件名称TDR935系列变压器保护装置技术说明书文件说明无版本记录版本日期修改人说明V1.00 2008-03-26 崔得志初始版本V2.00 2008-04-22 崔得志重新修订TDR935系列变压器保护装置技术说明书V 2.00 2008.04编写:崔得志张慧刘明辉王海兵范汇华审核:姚卫兵批准:金启超2008年4月目录1.简介 (1)2.特点 (2)3.应用 (2)4.保护原理 (3)4.1.差动保护专题 (3)4.2.后备保护专题 (6)5.TDR935型变压器差动保护装置 (10)5.1.适用范围 (10)5.2.保护配置 (10)5.3.装置特点 (10)5.4.保护定值 (10)5.5.典型接线图 (13)6.TDR935A型变压器后备保护装置 (14)6.1.适用范围 (14)6.2.保护配置 (14)6.3.测控配置 (14)6.4.装置特点 (14)6.5.保护定值 (15)6.6.典型接线图 (17)7.TDR935B型变压器后备保护装置 (18)7.1.适用范围 (18)7.2.保护配置 (18)7.3.测控配置 (18)7.4.装置特点 (18)7.5.保护定值 (19)7.6.典型接线图 (21)8.TDR935D型变压器保护装置 (22)8.1.适用范围 (22)8.2.保护配置 (22)8.3.测控配置 (22)8.4.装置特点 (23)8.5.保护定值 (23)8.6.典型接线图 (25)9.辅助功能 (26)9.1.人机界面 (26)9.2.故障录波 (27)I9.3.顺序事件记录 (27)9.4.开关变位记录 (27)9.5.矢量显示 (27)9.6.DRS软件的支持 (28)10.用户接口 (29)10.1.面板及显示 (29)10.2.按钮 (29)10.3.通信接口 (30)10.4.口令保护 (30)11.技术数据 (31)11.1.额定直流电压 (31)11.2.额定交流数据 (31)11.3.功率消耗 (31)11.4.保护部分精度 (31)11.5.测控部分精度 (31)11.6.开关量输入 (31)11.7.输出容量 (32)11.8.通讯接口 (32)11.9.电气环境 (32)11.9.1.直流电源 (32)11.9.2.绝缘电阻 (33)11.9.3.介质强度 (33)11.9.4.冲击电压 (33)11.9.5.脉冲群干扰 (33)11.9.6.辐射电磁场干扰 (34)11.9.7.静电放电干扰 (34)11.9.8.快速瞬变干扰 (34)11.9.9.正常工作大气条件 (34)11.10.机械环境 (34)12.定货须知 ............................................................................................................................... 3513.附录 (36)附录1.装置面板布置图 (37)附录2.装置背板布置图 (37)附录3.装置安装尺寸图 (38)附录4.操作回路原理图 (39)附录5.工程用装置电原理图 (42)TDR935变压器差动保护装置 (42)TDR935A变压器后备保护装置 (45)TDR935B变压器后备保护装置 (48)TDR935D变压器保护装置 (51)附录6.变压器差动保护整定示例 (54)注意:产品的型号、功能、配置可能由于软件版本升级有所改变,请注意最新版本资料。

ST300A配电自动化终端技术说明书

ST300A配电自动化终端技术说明书

ST300A配电自动化终端单元技术说明书V2.10珠海思创电气有限公司ZHUHAI STRONG ELECTRIC CO.,LTD目录1.装臵概述 (2)1.1型号定义 (2)1.2功能特点 (2)2.技术参数 (4)2.1额定参数 (4)2.2主要技术性能 (4)2.3绝缘性能 (5)2.4抗电磁干扰性能 (6)2.5机械性能 (7)2.6环境条件 (7)3.装臵硬件结构 (8)3.1硬件平台 (8)3.2结构与安装 (10)4.VIT原理及方案 (12)4.1主干线分段开关 (12)4.2分支线分段开关 (13)4.3联络开关 (13)5. 参数设臵 (15)5.1系统参数 (15)5.2定值参数 (16)6. 运行维护 (18)6.1 装臵送电前检查 (18)6.2 装臵运行检查 (18)6.3 装臵维护指南 (18)1.装臵概述ST300A配电自动化终端单元是为配电自动化装臵设计的核心监控单元,适用于柱上开关配套使用,属于ST300配电自动化终端系列的一种。

它具有独特的基于VIT原理的配网自动化动作逻辑功能,既能通过现有通讯网络与配网自动化主站、子站配合,实现故障监测、定位、隔离、控制、计量等功能,也能在现场无通讯信道的条件下,通过装臵的逻辑动作时序配合,实现故障的就地自动监测、定位、隔离等功能。

1.1型号定义ST300为我公司配网自动化终端系列产品专门型号,型号定义如下:ST 300 x装臵类型:A—柱上开关FTUB—环网柜或开闭所DTUC—自动重合控制器产品系列代号公司代码ST300A与柱上开关配合,通常用于监控一回线路,也可以监控相同电压等级的两条线路,适用于单杆双回线路的情况。

ST300B属于多输入量的监控终端,用于环网柜或开闭所,最多可以监控四回线路。

1.2功能特点ST300A配电自动化终端单元采用高性能工业级DSP(数字信号处理)芯片+专用微处理器,构成双CPU结构,软件上完全实现模块化、平台化,运行速度快,处理能力强,存储容量大,可扩展性好,可靠性高。

NDX300系列数字式线路保护装置说明书

NDX300系列数字式线路保护装置说明书

NDX300 系列数字式线路保护装置 说 明 书
南京南自电网控制技术有限责任公司
* 2006 年 10 月第二次印刷。 * 本说明书内容适用于 V1.XX 版本, 如有修改, 恕不另行通知, 请访问互联网: http://www.nps-naef.com 下载最新版本。
1.2 保护功能配置一览表
序号 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 保护功能 NDX310 光纤分相电流差动 光纤零序电流差动 三段式相间距离 三段式接地距离 二段式接地距离 四段式零序保护 三段式零序保护 三相一次重合闸 三段式方向过流保护 两段式过流保护 过负荷 加速段保护 双回线相继速动 不对称故障相继速动 低压减载 低周减载 TV 断线 TA 断线 故障测距 故障录波 出口操作回路 - - √ √ - √ - √ - √ √ √ √ √ √ √ √ - √ √ √ NDX311 - - √ - √ - √ √ - √ √ √ √ √ √ √ - √ √ √

录Hale Waihona Puke 1 装置简介 .................................................................... 1 1.1 适用范围 ................................................................ 1 1.2 保护功能配置一览表 ...................................................... 1 1.3 产品特点 ................................................................ 2 2 技术参数 ..................................................................... 4 2.1 环境参数 ............................................................... 4 2.2 额定电气参数 ........................................................... 4 2.3 主要技术指标 ........................................................... 4 2.4 光纤接口 ............................................................... 5 2.5 E1 接口 ................................................................. 5 2.6 通信接口 ............................................................... 5 2.7 绝缘性能 ............................................................... 6 2.8 电磁兼容 ............................................................... 6 2.9 机械性能 ............................................................... 6 2.10 机械结构 .............................................................. 7 3 原理说明 .................................................................... 12 3.1 差动保护 .............................................................. 12 3.2 距离保护 .............................................................. 16 3.3 零序电流保护 .......................................................... 20 3.4 三相重合闸 ............................................................ 21 3.5 过电流保护 ............................................................ 22 3.6 相电流加速段保护 ...................................................... 23 3.7 过负荷保护 ............................................................ 23 3.8 低周减载 .............................................................. 23 3.9 低压减载保护 .......................................................... 23 3.10 TA 异常检测 ........................................................... 24 3.11 母线 TV 断线 .......................................................... 25 3.12 线路 TV 断线 .......................................................... 25 3.13 远动功能 ............................................................. 25 3.14 对时功能 ............................................................. 25 3.15 故障录波功能 ......................................................... 26 3.16 辅助功能 ............................................................. 26 3.17 装置告警 ............................................................. 26 4 定值清单及说明 ............................................................ 27 4.1 NDX310 数字式线路保护装置定值 .......................................... 27 4.2 NDX311 数字式线路保护装置定值 .......................................... 32 4.3 NDX315 数字式线路保护装置定值 .......................................... 36 4.4 NDX316 数字式线路保护装置定值 .......................................... 41 4.5 NDX326 数字式线路保护装置定值 .......................................... 44

南自ndd300保护装置说明书

南自ndd300保护装置说明书

南自ndd300保护装置说明书
南京南自电网公司ND300系列保护装置以TI公司高性能的数字信号处理器DSP芯片为基础,并配置32位单片机完成辅助功能;工作主频100 MHz,CPU负荷率小于30%。

模拟通道采集采用AD公司基于Σ说/△(过采样)技术的16位A/D芯片,提高了采样的精度和可靠性;模数转换器采用串行接口、差分传输技术。

采用复杂可编程逻辑阵列CPLD,简化了外围电路,可方便地实现出口逻辑可编程功能。

通信接口丰富,包括双Ethernet工业以太网、CANBUS现场总线、RS-485、RS-232等。

开入、开出回路实现了二级光电隔离,进一步提高装置的可靠性。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

STN300数字式箱变保护测控装置一、概述为降低线路损耗,一般在风机终端或光伏逆变器旁配置 10/35KV 箱式升压站,他们间距达数百米,离集控室较远,且均处于空旷的野外,自然环境比较恶劣,不方便人工巡视,使得风电箱变和光伏箱变成为监控难点。

STN300数字式箱变保护测控装置能够对风电和光伏箱变进行保护和远程监控,全面实现对风电和光伏箱变的“遥信、遥测、遥控、遥调”功能;实现风电工程的“少人值班”的运行管理模式。

1.1 装置系列主要特点²装置采用最新一代高性能DSP内核的ARM,使产品的稳定性和运算速度得到充分保证;²标准6U 1/3 铝合金筒形机箱,深度适中,就地安装于风电箱内;²采集模块采用16位的A/D转换器,各项测量计算指标轻松达到要求;²配置大容量的存储模块,可记录10个录波报告,记录的事件数不少于500条,具有掉电保持功能;²高精度的时钟芯片,并配置有B码及GPS对时电路(二选一),便于全系统时钟同步;²配备高速以太网络通信接口(两光两电),并向下兼容485通讯接口;²采用大屏幕液晶,各项数据更加直观明了;²精心的电气设计,整机无可调节器件,实现了免调试概念设计;²高等级、高品质保证的元器件选用;²完善的自诊断功能;²防潮、防尘、抗振动的机箱设计;²48路开关量输入(含非电量输入);²8路继电器输出;²可选配6路直流量测量,3路热电阻输入,3路4-20mA输入;²可选配规约转换模块(8路串口),支持现场多种设备接入和规约转换,方便各种就地设备以光纤方式上传各种信息;²可用工作于超低温工作环境(如-40℃);²高抗干扰性,通过10项电磁兼容认证(快速瞬变、静电放电、浪涌抗干扰等)。

1.2 主要功能配置如下:Ø过电流保护Ø零序电流保护Ø非电量保护Ø反时限保护Ø低电压保护Ø过电压保护ØPT 断线ØI、U、P、Q、cosφ、Hz、48 路开关量采集二、技术参数2.1 额定参数2.1.1额定直流电压:AC/DC 86~275V2.1.2 额定交流数据:a) 相电压3/100 Vb) 交流电流 5A或1A(订货注明)c) 额定频率 50Hz2.1.3 功率消耗:a) 直流回路正常工作时:不大于10W动作时:不大于15Wb) 交流电压回路每相不大于0.5VAc) 交流电流回路额定电流为5A时:每相不大于1VA额定电流为1A时:每相不大于0.5VA 2.1.4 状态量电平: 220V或110V(订货注明)2.2 主要技术性能2.2.1采样回路精确工作范围电压:0.5 V~120V电流:0.08In-20In2.2.2接点容量信号回路接点载流容量 400VA信号回路接点断弧容量 60VA2.2.3跳合闸电流本装置跳合闸电流采用自适应模式,无需选择。

2.2.4各类元件精度电流元件: <±3%电压元件: <±3%检同期角度: <±1°时间元件: 0s-1s时,误差不超过30ms;1s以上时,误差不超过<±2.5%;2.2.5整组动作时间(包括继电器固有时间)速动段的固有动作时间:1.2倍整定值时测量,不大于30ms2.2.6 暂态超越不大于5%2.2.7模拟量测量回路精度装设专用测量子模件的测控装置:电流、电压:0.2级功率、电度:0.5级2.3 绝缘性能2.3.1绝缘电阻装置的带电部分和非带电部分及外壳之间以及电气上无联系的各电路之间用开路电压500V的兆欧表测量其绝缘电阻值,正常试验大气条件下,各等级的各回路绝缘电阻不小于100MΩ。

2.3.2介质强度在正常试验大气条件下,装置能承受频率为50Hz,电压2000V历时1分钟的工频耐压试验而无击穿闪络及元件损坏现象。

试验过程中,任一被试回路施加电压时其余回路等电位互联接地。

2.3.3冲击电压在正常试验大气条件下,装置的电源输入回路、交流输入回路、输出触点回路对地,以及回路之间,能承受1.2/50µs的标准雷电波的短时冲击电压试验,开路试验电压5kV。

2.3.4耐湿热性能装置能承受GB7261第21章规定的湿热试验。

最高试验温度+40℃、最大湿度95%,试验时间为48小时,每一周期历时24小时的交变湿热试验,在试验结束前2小时内根据2.3.1的要求,测量各导电电路对外露非带电金属部分及外壳之间、电气上不联系的各回路之间的绝缘电阻不小于1.5MΩ,介质耐压强度不低于2.3.2规定的介质强度试验电压幅值的75%。

2.4电磁兼容性能2.4.1静电放电抗干扰度通过GB/T 17626.2-1998标准、静电放电抗干扰4级试验。

2.4.2射频电磁场辐射抗干扰度通过GB/T 17626.3-1998标准、射频电磁场辐射抗干扰度3级试验。

2.4.3电快速瞬变脉冲群抗扰度通过GB/T 17626.4-1998标准、电快速瞬变脉冲群抗扰度4级试验。

2.4.4浪涌(冲击)抗扰度通过GB/T 17626.5-1999标准、浪涌(冲击)抗扰度3级试验。

2.4.5射频场感应的传导骚扰度通过GB/T 17626.6-1998标准、射频场感应的传导骚扰度3级试验2.4.6工频磁场抗扰度通过GB/T 17626.8-1998标准、工频磁场抗扰度5级试验2.4.7脉冲磁场抗扰度通过GB/T 17626.9-1998标准、脉冲磁场抗扰度5级试验。

2.4.8阻尼振荡磁场抗扰度通过GB/T 17626.10-1998标准、阻尼振荡磁场抗扰度5级试验。

2.4.9振荡波抗扰度通过GB/T 17626.12-1998标准、振荡波抗扰度4级试验。

2.5机械性能2.5.1振动装置能承受GB7261中16.3规定的严酷等级为I级的振动耐久能力试验。

2.5.2冲击装置能承受GB7261中17.5规定的严酷等级为I级的冲击耐久能力试验。

2.5.3碰撞装置能承受GB7261第18章规定的严酷等级为I级的冲击耐久能力试验。

2.6环境条件2.6.3环境温度:工作:-40℃~+55℃。

贮存:-40℃~+85℃,在极限值下不施加激励量,装置不出现不可逆的变化,温度恢复后,装置能正常工作。

a)相对湿度:最湿月的月平均最大相对湿度为90%,同时该月的月平均最低温度为25 ℃且表面无凝露。

最高温度为+40℃时,平均最大相对湿度不超过50%。

b)大气压力:86~106kPa(相对海拔高度2km以下)三、保护功能说明3.1 过电流元件装置实时计算并进行三段过流判别。

为了躲开线路避雷器的放电时间,本装置中I 段也设置了可以独立整定的延时时间。

装置在执行三段过流判别时,各段判别逻辑一致,其动作条件如下:1)I F>Idn;Idn为n段电流定值,I F为相电流2)T>Tdn ;Tdn 为n段延时定值Izd为n段电流定值,Ia,Ib,Ic为相电流。

3.2 零序过电流元件零序过电流元件的实现方式基本与过流元件相同,满足以下条件时出口跳闸:1)3I0>I0n ; I0n:接地N段定值2)T>T0n;T0n:接地N段延时定值3.3 反时限元件反时限保护元件是动作时限与被保护线路中电流大小自然配合的保护元件,通过平移动作曲线,可以非常方便地实现全线的配合。

常见的反时限特性解析式大约分为三类,即标准反时限、非常反时限、极端反时限,本装置中反时限特性由整定值中反时限指数整定。

各反时限特性公式如下:a.一般反时限(整定范围是0.007~0.14)b.非常反时限(整定范围是0.675~13.5)c.极端反时限(整定范围是4~80)其中: tp 为时间系数,范围是(0.05~1) Ip 为电流基准值 I 为故障电流t 为跳闸时间注意:整定值部分反时限时间为上面表达式中分子的乘积值,单位是秒.本装置相间电流及零序电流均带有定、反时限保护功能,通过设置控制字的相关位可选择定时限或反时限方式。

当选择反时限方式后,自动退出定时限II 、III 段过流及II 、III 段零流元件,相间电流III 段和零序电流III 段的功能压板分别变为相间电流反时限及零序电流反时限功能投退压板。

1)(802-=IpI tp t 1)(5.13-=IpI tp t 102.0(14.0-=IpItp t3.4 PT断线检测在下面三个条件之一得到满足的时候,装置报发“PT断线”信息并点亮告警灯:1.三相电压均小于8V,某相(a或c相)电流大于0.25A,判为三相失压。

2.三相电压和大于8V,最小线电压小于16V,判为两相或单相PT断线。

3.三相电压和大于8V,最大线电压与最小线电压差大于16V,判为两相或单相PT断线。

PT断线检测功能可以通过“模拟量求和自检”控制字投退。

3.5 过电压保护当电压大于设定值时,经延时跳闸或告警。

3.6 低电压保护当电压小于设定值且开关位置在合位时,经延时跳闸或告警。

3.7 非电量保护该保护功能为标准配置。

提供重瓦斯,轻瓦斯,超温跳闸及温度高告警和油位低、SF6异常保护的直跳接口。

并通过控制字选择延时跳闸/告警,同时采集遥信。

四、规约转换功能STN300采用了开放式设计思想,因而在站内通信网络的各层都采用了标准化的设计,其它制造商的设备完全可以使用通用的技术直接接入STN300的站内网。

然而,“海纳百川,有容乃大”,我们也考虑到使用者的实际需要,为了更多地兼容已有设备,STN300也专门设计了实现异种网络互连的规约转换模块。

该模块可以方便地将不提供以太网的微机化设备连接进变电站自动化系统的站内骨干网。

规约转换器模块可以在底层物理接口和到高层应用规约的各层次上进行双向的规约转换,让各种具备通信接口的智能设备在站内网上映射成一台虚拟的兼容装置或者将STS360系列装置映射到别的系统。

通过智能设备接口的转换,变电站自动化系统就大大延伸出信息共享的触角。

目前已经出现的IED设备类型很多,只要能够提供完整的通信规约,各种厂家的IED设备基本上都能被兼容。

并且得益于高级语言模块化编程和实时多任务操作系统的应用,在高效稳定的通信驱动模块基础上开发新规约的时间将会大大缩短。

借助可视化的编译调试工具和通信监视手段,设备间的联调也非常方便,所有这一切都导致从规约文本到高质量软件之间的开发过程显得非常明快和简单。

五、环网交换功能模块STN300箱变测控保护装置提供了两对具有环网交换功能的光接口模块。

光口将网络传输距离的极限从双绞线的100米扩展到了50公里以上,它可以简单地实现多台主板服务器、中继器、集线器、终端机与多台终端机之间的互联。

相关文档