秒开缓存系统使用说明书最新版
JUKI ISM ULTRAFLEX 3600自动存储系统使用指南说明书

STORAGE SOLUTIONISM ULTRAFLEX 3600Automated storage systemsStatic storage systemsISM 500ISM ULTRAFLEX 3900ISM 400ISM 2000ISM 1100EFFICIENT STORAGE MANAGEMENT –A DECISIVE FACTOR OF SUCCESSSTORAGE MANAGEMENT SYSTEMSIntelligent and efficient storage management has become an increasingly important factor of success in SMT production processes. It is the only way to ensure optimum output teamed with a more flexible product line. Besides, it is a crucial element on the road to Industry 4.0.JUKI ISM storage management systems facilitate exactly this intelligent and flexible type of warehousing. By minimising the manual expenditure of time, it is possible to shift the focus on value-creating activities. An efficient storage management system saves time and money during the entire production process. Apart from that, it regularly communicates with your ERP/MES system.JUKI STORAGE SOLUTION includes a wide range of different intelligent storage cabinets for your stock of components. STORAGE SOLUTION allows for flexible assembly and modular extension. What is more, it enables the smart integration of existing storage systems.It is JUKI‘s goal to closely cooperate with their customers in order to develop an ideal, customised and intelligent storage concept – regardless of the particular requirements.ADVANTAGES OF JUKI STORAGE SOLUTION2STORAGE SOLUTIONOPTIMISED MATERIAL FLOWFEEDER SETUP WITH STORAGE SYSTEMSRE-STORAGE OF LEFTOVER MATERIAL UPON COMPLETION OF PRODUCTION3STORAGE SOLUTION4STORAGE SOLUTIONISM UltraFlex 3600 ISM UltraFlex 39005STORAGE SOLUTION SOFTWARE WITH MANY ADVANTAGESComprehensive storage managementIncluded in the scope of delivery, the AutoSMD software guarantees comprehensive storage management. The inventory level in-cluding both the available and the allocated quantities can be controlled at all times. Thanks to the order preparation and planning functionality, the required parts as well as the SMD and THT components will be blocked. Thus, those parts will be excluded from planning. Once the minimum stock level has been reached, it is possible to automatically send a request for material to the ERP system. In order to be able to react in time, you can always update your stocks in your ERP/MES systems.EFFICIENT STORAGE THANKS TO INTELLIGENT STORAGE SOFTWAREPaperless order managementThanks to the electronic order planning and inventory removal management, a nnoying material printouts are a thing of the past. The material is made available to theo perator. Material requested by the pick and place machine can be directly retrieved from storage .Connection to ERP/MES systems and production linesThe AutoSMD software can be connected to all known MES/ERP systems, which facilitates the exchange of data at all levels. The entire production chain, including the supply chain, can thus work in a transparent and efficient manner. Since the ISM towers can be used regardless of the brand, they do not necessarily have to be used along with a JUKI production line. Moreover, the material can be automatically entered into an existing ERP/MES system.TraceabilityA comprehensive barcode library enables automatic material recognition upon storage, which reduces the error rate to a significant extent. In order to allow future error analyses, traceability pictures of each reel are saved at the same time.Monitoring of MSD components MSD components are monitored by the system, the floor time is tracked at package level, and expired material will not be released for orders. Thus, the reject rate relating to components and finished PCBs is reduced significantly.It is possible to integrate an existing storage system – regardless of whether it is another automated storage system or a high-bay warehouse – into the JUKI storage management system. The space required in a high-bay warehouse will be optimised by the dynamic (chaotic) type of warehousing.Inventory removal occurs in a route- optimised way by means of a PDA. Thus, you will save time and minimise human errors during the retrieval process.Integration of existing storage systems6STORAGE SOLUTIONAUTO INCOMING DESKReceiving goods in one stepThe JUKI material auto incoming desk allows receiving goods in one step. All you have to do is place the component reel on the glass plate above the camera. The whole process is a utomated: material recognition, print of the unique ID barcode label and entry into the database. The system registers the components in a straightforward, easy and reliable way. Thus, they can be stored immediately or made available for production.FULLY-AUTOMATED STORAGE SYSTEMISM UltraFlex 3600 and ISM UltraFlex 3900EfficiencyUser interaction is not required during the fully-automated storage or retrieval of up to 54 reels. Meanwhile, the employee can complete other tasks. Besides, automateds torage saves valuable time, time that – in case of traditional shelf warehouses – is otherwise spent for manual commissioning, the search for material as well as fors torage and re-storage.Space-saving solutionUsing the ISM UltraFlex 3600, up to approx. 3,600 7-inch reels may be flexibly stored on a floor space of only 3.6 m 2. Naturally, there are also solutions for 15-inch reels and for the shared storage of 7- and 15-inch reels. Moreover, it is possible to more thand ouble the capacity of the ISM UltraFlex 3600 by adding the ISM UltraFlex 3900 e xtension module.Protected by cases, the component reels are always stored in a clean and safe way. ESD compliance is guaranteed at all times. Moreover, the cases facilitate quick re-storage, which also applies to reels that are damaged or slightly bent out of shape. Maximum storage space optimisation is ensured by the dynamic (chaotic) type of warehousing. Cases with differentheights are stored space-saving in the tower.Cases in storageCases with flexible height adjustment Double caseView into the towerISM UltraFlex 3900 extension moduleBy adding an ISM UltraFlex 3900 module, you will more than double your storage capacity. The ISM UltraFlex 3900 and the ISM UltraFlex 3600 are interconnected by two conveyor belts. Both will then act as a single unit with a total storage capacity of up to 7,500 reels.Error preventionFully-automated storage prevents human allocation errors. All sources of error are eliminated, because all materials are scanned and photographed during storage process. What is more, the internal system software can report stored materials and any missing parts back to the existing ERP system.MSD monitoringThe optional humidity control keeps the humidity inside the system at 5% RH. Delicate MSD components are thus protected against excessive humidity (RH > 5%). Besides, the software records the prevailing humidity throughout the component‘s entire storage cycle. Expired components will be blocked for the production.AUTOMATED STORAGE SYSTEMISM 2000 and ISM 1100Patented multiple pick positionsAutomated storage systems have been developed with the objective of achieving optimum performance when it comes to storage capacity and overall size. Thanks to these systems, reels and trays stored in cases can be stored and retrieved very rapidly. The patented multiple pick positions allow moving up to 27 reels into and out of storage at the same time. This applies to all products available.All models available are listed on the back of this brochure.STATIC STORAGE SYSTEM Array Storage space for different types of componentsJUKI has designed static storage systems for the manual, smartand dynamic (chaotic) storage and retrieval of different materialssuch as reels, JEDEC trays, SMT/THT bars, prepared feeders, PCBs,THT components and much more.All models available are listed on the back of this brochure.7STORAGE SOLUTIONSPECIFICATIONS05/2018_R e v 01Specifications and design subject to change without notice.European Headquarters:JUKI Automation Systems GmbHNeuburger Str. 41, 90451 Nuremberg, Germany phone: +49 911 93 62 66 0 fax: +49 911 93 62 66 26email:*****************。
PNS3.0旗舰版用户手册

虚拟桌面快速交付系统软件 V3.0
QuickDesktop 虚拟桌面快速交付系统软件 V3.0 旗舰版使用手册
苏州江波软件技术有限公司
-1-
QuickDesktop
虚拟桌面快速交付系统软件 V3.0
目录
第一章 1.1 1.2 第二章 第三章 3.1 3.2 3.3 第四章 4.1 4.2 4.3 4.4 第五章 5.1 5.2 5.3 5.4 第六章 6.1 6.2 6.3 6.4 第七章 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 第八章 8.1 8.2 8.3 8.4 8.5 产品简介 .......................................................................................................................................................... 4 产品概述 ................................................................................................................................................... 4 产品安装环境 ........................................................................................................................................... 4 QUICKDESKTOP 的安装流程说明 ..........................
存储服务器使用说明书

存储服务器 操作手册目录第一章存储服务器的功能........................................................................................................- 2 -1.1功能概述........................................................................................................................- 2 -1.2性能概述........................................................................................................................- 2 -1.3运行环境........................................................................................................................- 3 - 第二章存储服务器的使用........................................................................................................- 4 -2.1运行前的准备................................................................................................................- 4 -2.1.1磁盘的组织.........................................................................................................- 4 -2.1.2原始数据库文件.................................................................................................- 4 -2.1.3 确认运行环境....................................................................................................- 5 -2.2服务器操作说明............................................................................................................- 5 -2.2.1首次运行.............................................................................................................- 5 -2.2.2主界面说明.........................................................................................................- 6 -2.2.3启动服务器.........................................................................................................- 7 -2.2.4停止服务器.........................................................................................................- 8 -2.2.5系统配置.............................................................................................................- 8 -2.2.6退出.....................................................................................................................- 8 -2.2.7配置录像计划.....................................................................................................- 8 -2.2.8未录通道日志记录功能.....................................................................................- 9 - 第三章存储服务器的数据库备份..........................................................................................- 10 -3.1 数据库的备份还原.....................................................................................................- 10 -3.2存储服务器的重新安装..............................................................................................- 11 -第一章存储服务器的功能1.1功能概述存储服务器软件实现对监控录像数据的统一保存,它通过直接连接设备或者通过流媒体服务器获取视频数据流,并以数据块的方式保存在预分配的磁盘空间中,通过磁盘数据的索引文件保存录像数据信息。
Browser Security Plus 快速用户手册说明书

Browser Security Plus快速用户手册ME产品部2023-09-01本文档旨在帮助用户快速熟悉产品的使用方法。
Tel: 4006608680 https:// 1 /目录一. 简介 (4)二.系统安装 (4)1. 安装 (4)2. 启动Browser Security Plus (9)2. 关闭Browser Security Plus (10)3. 登录Browser Security Plus (11)4. 添加计算机 (11)三.管理 (13)1.计算机和组 (13)2.网站组 (14)3.扩展存储库 (14)四.策略 (15)1.附加组件管理 (15)2.下载限制 (16)3.威胁防护 (16)4.防止数据泄漏 (17)5.浏览器定制 (17)6.浏览器路由器 (18)7.浏览器锁定 (18)8.Java管理器 (19)9.Web过滤器 (19)10.网络隔离 (20)11.浏览器限制 (20)五.性能透视 (21)六.合规性 (23)七.产品文档 (24)一. 简介随着许多业务应用程序转移到云中,浏览器正成为员工最常用于访问其工作的工具。
因此,黑客跟随这种趋势通过尝试通过浏览器利用组织的行为也就不足为奇了。
最近,组织看到基于浏览器的威胁在稳步增长。
Browser Security Plus将帮助您抵御这些攻击,使其无法进入您的网络。
其功能旨在帮助您检测网络中的任何漏洞或有害组件,执行安全配置,控制用户对浏览器的访问量和加载项的访问权限,并最终进行审核以检查是否违反规定的标准。
这是Browser Security Plus帮助IT管理员抵抗基于浏览器的攻击的方法。
Browser Security Plus的特点:⚫防止通过浏览器传播的网络攻击并提高浏览器的安全性。
⚫保护在浏览器上和通过浏览器共享的数据到Web应用程序/云。
⚫帮助您对正在使用的浏览器保持警惕,并了解它们是否最新。
AS500G 浪潮海量存储系统软件用户手册 2.0

目 录第1章 新手上路 (2)1.1 登录 (2)第2章 存储资源 (4)2.1 磁盘信息 (4)2.2 卷组管理 (7)2.3 逻辑卷管理 (9)第3章 主机组管理 (13)3.1 概述 (13)3.2 IPSAN主机组管理 (13)3.3 IPSAN会话管理 (17)3.4 FC主机组管理 (17)3.5 FC会话管理 (20)第4章 网络设置 (21)4.1 基本设置 (21)4.2 网络连接 (21)4.3 设备信息 (24)第5章 系统选项 (26)5.1 时间日期 (26)5.2 系统日志 (27)5.3 系统恢复和升级 (29)5.4 配置管理 (30)5.5 管理员设置 (32)5.6 系统监控设置 (33)5.7 系统状态 (36)5.8 系统吞吐量 (37)5.9 系统电源管理 (38)第6章 超级终端 (40)6.1 登录系统 (40)6.2 用户接口命令 (40)附录Ⅰ:Windows上启动器的安装及使用 (42)附录II: Linux上启动器的安装和使用 (47)附录Ⅲ:目标器命名规范 (54)附录Ⅳ:IP-SAN使用快速指南 (56)第1章 新手上路1.1 登录用户可以通过Web浏览器访问浪潮海量存储系统软件,建议使用Firefox3.0及以上版本,IE8.0,以1024*768的分辨率浏览。
浪潮海量存储系统软件出厂设置的IP为192.168.1.128和192.168.1.129,需要在同一网段的管理员控制台上登录,在管理员控制台的浏览器地址栏中输入: http: //192.168.1.128 或者http://192.168.1.129即可登录显示界面,其中192.168.1.12 8为控制器0的IP,192.168.1.129为控制器1的IP。
系统默认管理员账户为root,密码为root。
如图1-1-1-1所示。
图1-1-1-1 登录界面登录之后系统即显示主页面,主页面包括四个部分:控制器状态显示、主功能区、辅助功能区、操作显示区。
秒开缓存系统使用说明书最新版

秒开缓存系统V4.0使用说明书尊敬用户:感谢您使用秒开缓存系统!秒开缓存系统V4.0版采用旁路镜像部署,具有对原有网络无干扰、能根据带宽状况智能回源、支持按文件扩展名进行全网缓存、支持多机集群运行和网络存储等特点,是一款适合大中型宽带运营商、高校、大型企业使用缓存加速系统。
本使用说明书可以帮助您快速调试和使用秒开缓存系统。
快速调试指南在系统调试之前,系统已安装好。
有关系统安装见《秒开软件安装说明书》在开始调试之前,先了解一下秒开缓存系统能正常工作的条件:第一:缓存能采集到用户上网请求,这是通过镜像口的数据采集功能来实现的;第二:客户机能够收到缓存服务器发出重定向数据包和命中数据包,客户机与缓存服务器之间通讯无阻碍;第三:缓存能上网,能够从远程服务器回源数据。
下面将用“step by step"方式介绍缓存系统V4.0的调试方法。
Step 1: 确定部署方案,调试好镜像交换机官方推荐2种部署模式,拓扑图如下:注:推荐部署方式可以适应各种网络环境,无需根据不同网络环境对缓存做不同调整。
推荐部署模式1:(注意交换机镜像设置)(图1)推荐部署模式2:(注意交换机镜像设置)(图2)如果不方便使用前2种推荐方式部署,也可以使用下面部署方式:(图3)注:在设置交换机镜像口时,最好是镜像上行流量,如果交换机不支持,镜像双向流量也行。
Step 2: 控制台登录修改IP接上显示器和键盘,开机启动,系统启动完毕后,主板蜂鸣器会发出三声短暂的提示音:“滴---滴滴”。
在控制台可以修改命中口的IP和网关(系统默认命中口IP是192.168.1.254,网关是192.168.1.1),网关是路由LAN口IP,命中口IP是和网关同一网段一个空闲固定IP。
注意:按推荐部署模式1接的,网关为路由LAN口扩展IPStep 3: 登录WEB控制页,绑定网口按部署方案先接好命中口,把客户机IP设为与缓存命中口IP同一网段,打开客户机浏览器,输入http://命中口IP:8014,进入登录页面,如图所示:(图4)登录后,先先绑定命中口网卡(建议按系统默认的),然后再插上镜像口网线,绑定镜像网口,然后根据情况是否需要绑定上网口(独立上网时需要绑定上网口)。
酒店光纤布线方案实现三网合一

一.小型酒店光纤布线方案(酒店房间小于80间)1. 光纤布线方案网络拓扑图如下:说明:机房到各房间以及各信息接入点全部采用光纤连接,机房端采用标准OLT设备,终端采用秒开ONU。
宽带:通过FTTH+LAN的方式,直连到每个房间,每个房间一个宽带账号,将宽带账号设置在ONU上即可连接互联网。
电话:各个房间电话接入ONU,再通过FTTH接入IP PBX(网络电话程控交换机)。
IPTV系统:各个房间IPTV机顶盒或定制智能电视机接入ONU(如果采用夏普商用电视机或创维工程电视机,可无需配机顶盒),再通过FTTH接入秒开酒店互动电视服务器(提供电视直播和视频点播),直播节目源通过网络获取(酒店互动电视服务器需独立上网,并保证一点带宽),提供网络视频点播,光纤布线方案分享。
客房WIFI:采用ONU自带WIFI上网。
公共区域WIFI:无线AP接入ONU(小区域可直接使用ONU自带WIFI)。
监控:摄像头接入ONU(可与无线AP共享一台ONU)2. 网络设备二.中型酒店光纤布线方案(酒店房间小于200间)1. 光纤布线方案网络拓扑图如下:说明:机房到各房间以及各信息接入点全部采用光纤连接,机房端采用标准OLT设备,终端采用秒开ONU。
宽带:通过FTTH+LAN的方式,直连到每个房间,每个房间一个宽带账号,将宽带账号设置在ONU上即可连接互联网。
电话:各个房间电话接入ONU,再通过FTTH接入IP PBX(网络电话程控交换机)。
IPTV系统:各个房间IPTV机顶盒或定制智能电视机接入ONU(如果采用夏普商用电视机或创维工程电视机,可无需配机顶盒),再通过FTTH接入秒开酒店互动电视服务器(提供电视直播和视频点播),直播源通过网络或第三方设备获取,建议额外建立视频点播服务器(VOD),提供芒果TV正版片源本地播放。
客房WIFI:采用ONU自带WIFI上网。
公共区域WIFI:无线AP接入ONU(小区域可直接使用ONU自带WIFI)。
塞Gate媒体应用程序用户手册说明书

Windows 用户手册欢迎使用此媒体应用程序可帮助您管理复制到兼容的无线和网络连接存储设备的媒体及文档。
它可作为移动设备的应用程序使用,或在 Web 浏览器中使用。
在家中或外出时,您随时都可使用此媒体应用程序欣赏音乐、电影和照片或查看重要的文档。
最新功能Seagate Media 版本 2.9 提供自动上载和共享功能。
有关媒体应用程序更新、常见问题、指导视频和支持信息的信息,请访问技术支持。
Seagate Media 和 Windows T ouch 为方便使用,Seagate Media 兼容标准的 Windows 8 和 Windows RT 触控功能:应用程序栏:将您的手指从屏幕顶部向下滑动可启用此应用程序栏。
您也可以将手指在屏幕上从下向上滑动。
执行相同的操作可退出此应用程序栏。
应用程序栏功能在屏幕的顶部和底部显示。
超级栏:从屏幕的右边缘开始,通过从右向左滑动手指来启用超级栏。
触摸屏幕上的任意位置可退出超级栏。
屏幕:触摸您设备上的 Windows 图标可返回到 Windows 返回到 Windows“开始”屏幕:的“开始”屏幕。
媒体应用程序用程序::在返回到 Windows 的“开始”屏幕或切换到另一个应用程序前,退出媒体退出没有必要退出媒体应用程序。
但有时退出此应用程序非常有用,例如在进行故障排除时。
要退出打开的应用程序,请将您的手指放到屏幕的顶部中央并向下滑动。
鼠标和键盘超级栏:将鼠标光标放到右下角可打开超级栏。
屏幕:触摸您设备上的 Windows 图标可返回到 Windows 返回到 Windows“开始”屏幕:的“开始”屏幕。
媒体应用程序用程序::在返回到 Windows 的“开始”屏幕或切换到另一个应用程序前,退出媒体退出没有必要退出媒体应用程序。
但有时退出此应用程序非常有用,例如在进行故障排除时。
要退出打开的应用程序,请按 Ctrl+Alt+Del 并选择“任务管理器”。
选择打开的应用程序并选择结结束任务。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
秒开缓存系统V4.0使用说明书
尊敬用户:
感谢您使用秒开缓存系统!秒开缓存系统V4.0版采用旁路镜像部署,具有对原有网络无干扰、能根据带宽状况智能回源、支持按文件扩展名进行全网缓存、支持多机集群运行和网络存储等特点,是一款适合大中型宽带运营商、高校、大型企业使用缓存加速系统。
本使用说明书可以帮助您快速调试和使用秒开缓存系统。
快速调试指南
在系统调试之前,系统已安装好。
有关系统安装见《秒开软件安装说明书》
在开始调试之前,先了解一下秒开缓存系统能正常工作的条件:
第一:缓存能采集到用户上网请求,这是通过镜像口的数据采集功能来实现的;
第二:客户机能够收到缓存服务器发出重定向数据包和命中数据包,客户机与缓存服务器之间通讯无阻碍;
第三:缓存能上网,能够从远程服务器回源数据。
下面将用“step by step"方式介绍缓存系统V4.0的调试方法。
Step 1: 确定部署方案,调试好镜像交换机
官方推荐2种部署模式,拓扑图如下:
注:推荐部署方式可以适应各种网络环境,无需根据不同网络环境对缓存做不同调整。
推荐部署模式1:(注意交换机镜像设置)
(图1)
推荐部署模式2:(注意交换机镜像设置)
(图2)
如果不方便使用前2种推荐方式部署,也可以使用下面部署方式:
(图3)
注:在设置交换机镜像口时,最好是镜像上行流量,如果交换机不支持,镜像双向流量也行。
Step 2: 控制台登录修改IP
接上显示器和键盘,开机启动,系统启动完毕后,主板蜂鸣器会发出三声短暂的提示音:“滴---滴滴”。
在控制台可以修改命中口的IP和网关(系统默认命中口IP是192.168.1.254,网关是192.168.1.1),网关是路由LAN口IP,命中口IP是和网关同一网段一个空闲固定IP。
注意:按推荐部署模式1接的,网关为路由LAN口扩展IP
Step 3: 登录WEB控制页,绑定网口
按部署方案先接好命中口,把客户机IP设为与缓存命中口IP同一网段,打开客户机浏览器,输入http://命中口IP:8014,进入登录页面,如图所示:
(图4)
登录后,先先绑定命中口网卡(建议按系统默认的),然后再插上镜像口网线,绑定镜像网口,然后根据情况是否需要绑定上网口(独立上网时需要绑定上网口)。
操作:进入“系统设置”-》“网卡绑定”,点击“添加网卡绑定”
必须绑定端口是命中口、镜像口,其他口根据需要确定是否需要绑定。
说明:
1. 命中口可以做多网口汇集,需要交换机支持,网络规模不大,不必做多口汇集。
2. 回传口设置:在推荐方案1或2时,回传口建议使用镜像口,部署方案3建议使用命中口(回传口不设置时会默认使用命中口回传,回传的意思是缓存向客户机发302重定向包)
3. 在缓存独立上网时,必须绑定上网口,绑定后显示是WAN口。
Step 4: 上网口及DNS设置
一般默认为命中口上网,如果要使用独立外线上网,先需要绑定上网口(step 3),DNS 一般可以保留系统默认的,再加上缓存上网线路的DNS。
操作:进入“系统设置”-》“DNS配置”,点击“增加DNS”
Step 5: 集群设置
V4.0版可以多机集群
如果是一台服务器,本机要设为调度服务器,系统会默认本机也是节点服务器。
如果是多台服务器,要设其中一台为调度服务器,系统也会默认此机为节点服务器,另外可以添加其他机器为节点服务器。
操作:进入“系统设置”-》“集群设置”,点击“开启作为调度服务器”,如有节点服务器,点击“添加节点服务器”。
(图5)
在节点服务器192.168.1.219中,也需要在集群中进行设置,如图所示:
操作:打开节点服务器WEB管理页,进入“系统设置”-》“集群设置”,填入调度服务器IP,点击“保存”。
(图6)
Step 6: 静态路由设置
在缓存服务器上网和客户机上网不是通过同一路由时,需要设置静态路由。
常见的情况是:第一:客户机PPPoE拨号上网,而缓存服务器独立上网;
第二:多台路由接入,而缓存通过其中一台路由上网的。
如图是秒开缓存独立上网时的静态路由设置
操作:进入“系统设置”-》“静态路由配置”,开启“静态路由”,点击“添加规则”
(图7)
Step 7: 磁盘管理设置
系统会提示没有初始化的磁盘要进行初始化,初始化好的磁盘要加入存储池中才能缓存数据。
操作:进入“系统设置”-》“存储管理”,点击“磁盘管理”,选择“磁盘初始化”,把初始化完成磁盘加入到存储池中。
(图8)
Step 8: 加速设置
V4.0版按文件扩展名进行缓存和命中,不是按域名来缓存和命中。
所以系统允许用户自定义文件扩展名(支持下载文件扩展名,音乐文件扩展名,视频文件扩展名,但不支持图片文件扩展名)。
初级用户可以直接选择“载入默认规则”,保存就行,而无须做其他更改就行。
高级用户可以自定义,如图所示:
操作:进入“加速设置”-》“加速配置”,点击“加速规则配置”,点击“载入默认规则”后,选择规则点击“编辑”,最后保存。
(图9)
说明:在网络规模较大时,可以开启“回源过滤”,开启回源过滤后,系统会自动忽略部分回源请求,降低系统负载,但在路由WAN口部署时(模式1和模式2)千万不要开启。
Step 9: 回源时间配置
V4.0版具有智能回源功能,能根据带宽状态或设置条件安排不同任务量回源。
说明:所谓回源就是从外网下载缓存数据,回源量越大对上网带宽要求也越高,为避免繁忙时段缓存回源与用户上网争夺带宽资源,建议用户设置网络使用繁忙时段和空闲时段。
操作:进入“加速设置”-》“加速配置”,点击“时间回源配置”,在配置区域拖动选择区域,点击右键,选择相应选项。
(图10)
Step 10: 限速设置
V4.0版具有不同限速段的限速功能,该功能需要路由配合(需要在路由中按同样地址池进
行不同限速设置)。
操作:进入“加速设置”-》“命中限速”,点击“添加限速”
(图11)
Step 11: 验证是否正常工作
第一:检查缓存上网情况,如图所示为正常(如不正常,需要在路由上进行设置)
操作:进入“首页”,点击“一键检测上网”
(图12)
第二:实时流量监测,如图所示为正常情况(如不正常,需检查镜像交换机设置及缓存设置)操作:进入“日志分析”-》“实时流量监测”
(图13)
第三:查看日记记录,刚开始测试时请查看请求记录,工作一段时间后可以查看命中记录。
如图所示为正常情况(如不正常,需检查缓存设置)
操作:进入“日志分析”-》“日志记录”
(图14)
为此为止,可以判断缓存已经开始正常工作了。
说明:V4.0版相比V3.0版,见效时间要长些,但因为命中机制适应性强,支持缓存内容多,一旦部署成功,可以稳定工作,命中效果会随着缓存数据增加越来越好。
常见问题
1.秒开缓存系统V4.0版支持哪些内容缓存?
答:秒开缓存系统V4.0支持按文件扩展名进行缓存加速,大致分类是:视频文件、音频文件、下载文件、移动APP、测速软件等。
与原有版本不同,不支持DNS缓存和图片缓存。
2.秒开缓存系统V4.0版有几种部署模式?
答:只有旁路镜像部署模式一种。
3.我怎么检查数据走缓存了?
答:下载Google浏览器(Chrome),安装成功后,打开浏览器,按F12,再打开网页,按下图所示进行检查,如果Remote Address是缓存的IP地址即成功。
(图15)
4.镜像交换机如何设置?
答:一般可管理交换机,镜像端口可以随意指定,被镜像端口为接路由WAN口(镜像交换机部署在路由前面时)或LAN的端口(镜像交换机部署在路由后面时)。
如果交换机设置有VLAN,接MQ命中口的端口需要设置为trunk模式,允许与所有VLAN通信。
5.为什么已经采集了用户请求(有镜像流量)缓存还是没有正常工作(服务流量为零,也无任何记录)?
答:常见有3种原因会导致该现象发生:
第一:镜像流量不正确,镜像流量中没有用户上网的上行流量,需重新设置交换机镜像端口。
第二:缓存服务器发出的数据无法到达客户机,一般是内部网络所导致,需检查交换机设置或重新绑定回传口。
第三:缓存服务器磁盘管理存在问题,需重新设置磁盘。
6.秒开缓存V3.0用户可以直接升级到V4.0吗?
答:可以,需采用ISO文件完整升级,升级后需重新部署并设置缓存系统。