热电偶分度表

合集下载

热电偶分度表

热电偶分度表

热电偶分度表K型热电偶分度表 K 参考端温度:0℃ 整10度mν值℃010********00.0000.3970.79801.20301.61102.02210004.09504.50804.91905.32705.73306.13720008.13708.53708.93809.34109.74510.15130012.20712.62313.03913.45613.87414.29240016.39516.81817.24117.66418.08818.51350020.64021.06621.49321.91922.34622.77260024.90225.32725.75126.17626.59927.02270029.12829.54729.96530.38330.79931.21480033.27733.68634.09534.50234.90935.31490037.32537.72438.12238.51938.91539.310100041.26941.65742.04542.43242.81743.202110045.10845.48645.86346.23846.61246.985120048.82849.19249.55549.91650.27650.633130052.39853.09353.09353.43953.78254.125N型热电偶分度表 N 参考端温度:0℃ 整10度mν值℃010********00.0000.2610.5250.79301.06501.34010002.77403.07203.37403.68003.98904.30220005.91306.24506.57906.91607.25507.59730009.34109.69610.05410.41310.77411.13640012.97413.34613.71914.09414.46914.84650016.74817.13117.51517.90018.28618.67260020.61321.00321.39321.78422.17522.56670024.52724.91925.31225.70526.09826.49180028.45528.84729.23929.63230.02430.41690032.37132.76133.15133.54133.93034.319100036.25636.64137.02737.41137.79538.179110040.08740.46640.84541.22341.60041.976120043.84644.21844.58844.95845.32645.694130047.513E型热电偶分度表 E 参考端温度:0℃ 整10度mν值℃010********00.0000.59101.19201.80102.41903.04710006.31706.99607.68308.37709.07809.78720013.41914.16114.90915.66116.41717.17830021.03321.81422.59723.38324.17124.96140028.94329.74430.54631.35032.15532.96050036.99937.80839.42640.23641.04541.85360045.08545.89146.69747.50248.30649.10970053.11053.90754.70355.49856.29157.08380061.02261.80662.58863.36864.14764.92490068.78369.54970.31371.07571.83572.593100076.358J型热电偶分度表 J 参考端温度:0℃ 整10度mν值℃010********00.0000.50701.01901.53602.05802.58510005.26805.81206.35906.90707.45708.00820010.77711.33211.88712.44212.99813.55330016.32516.87917.43217.98418.53719.08940021.84622.39722.94923.50124.05424.60750027.38827.94928.51129.07529.64230.21060033.09633.68334.27334.86735.46436.06670039.13039.75440.38241.01341.64742.28380045.49846.14446.79047.43448.07648.71690051.87552.49653.11553.72954.32154.948100057.94258.53359.12159.70860.29360.876110063.77764.35564.93365.51066.08766.664120069.536T型热电偶分度表 T 参考端温度:0℃ 整10度mν值℃010********00.0000.3910.78901.19601.61102.03510004.27704.74905.22705.71206.20406.70220009.28609.82010.36010.90511.45612.01130014.86015.44316.03016.62117.21717.816S型热电偶分度表 S 参考端温度:0℃ 整10度mν值℃010********00.0000.0550.1130.1730.2350.2991000.6450.7190.7950.8720.95001.02920001.44001.52501.61101.69801.78501.87330002.32302.41402.50602.59902.69202.78640003.26003.35603.45203.54903.64503.74350004.23404.33304.43204.53204.63204.73260005.23705.33905.44205.54405.64805.75170006.27406.38006.48606.59206.69906.80580007.34507.45407.56307.67207.78207.89290008.44808.56008.67308.78608.89909.012100009.58509.70009.81609.93210.04810.165110010.75410.87210.99111.11011.22911.348120011.94712.06712.18812.30812.42912.550130013.15513.27613.39713.51913.64013.761140014.36814.48914.61014.73114.85214.973150015.57615.69715.81715.93716.05716.176160016.77116.89017.00817.12517.24517.360R型热电偶分度表 R 参考端温度:0℃ 整10度mν值℃010********00.0000.0540.1110.1710.2320.2961000.6470.7230.8000.8790.95901.04120001.46901.55801.64801.73901.83101.92330002.40102.49802.59702.69602.79602.89640003.40803.51203.61603.72103.82703.93350004.47104.58004.69004.80004.91005.02160005.58305.69705.81205.92606.04106.15770006.74306.86106.98007.10007.22007.34080007.95008.07308.19708.32108.44608.57190009.20509.33309.46109.59009.72009.850100010.50610.63810.77110.90511.03911.173110011.85011.98612.12312.26012.39712.535120013.22813.36713.50713.64613.78613.926130014.62914.77014.91115.05215.19315.334140016.04016.18116.32316.46416.60516.746150017.45117.59117.73217.87218.01218.152160018.84918.98819.12619.26419.40219.540170020.22220.35620.48820.62020.74920.877B型热电偶分度表 B 参考端温度:0℃ 整10度mν值℃010********00.000-0.002-0.003-0.0020.0000.0021000.0330.0430.0530.0650.0780.0922000.1780.1990.2200.2430.2660.2913000.4310.4620.4940.5290.5610.5964000.7860.8270.8700.9130.95701.00250001.24101.29201.34401.39701.45001.50560001.79101.85101.91201.97402.03602.10070002.43002.49902.56902.63902.71002.78280003.15403.23103.30803.38703.46603.54690003.95704.04104.12604.21204.29804.386100004.83304.92405.01605.10905.20205.297110005.77705.87505.97306.07306.17206.273120006.78306.88706.99107.09607.20207.308130007.84507.95308.06308.17208.28308.393140008.95209.06509.17809.29109.40509.519150010.09410.21010.32510.44110.55810.674160011.25711.37411.49111.60810.72511.842170012.43612.54312.65912.77612.89213.008180013.58513.69913.814钨铼5-钨铼26热电偶分度表 W5/26 参考端温度:0℃ 整10度mν℃010********00.0000.1350.7230.4120.5540.69910001.45101.60701.76601.92502.08702.25020003.08903.26103.43503.60903.78503.96230004.86405.04705.23105.41605.60205.78840006.73106.92207.11307.30407.49607.68850008.65508.85009.04409.23909.43409.62960010.60610.80210.99711.19311.38811.58470012.55912.75312.94813.14213.33613.53080014.49414.68614.87815.06915.26015.45190016.39716.58516.77316.96017.14717.333100018.25718.44118.62318.80618.98719.169110020.06620.24420.42220.59820.77520.950120021.82021.99222.16322.33422.50522.674130023.51423.68023.84624.01124.17524.339140025.14925.30925.46825.62725.78525.943150026.72326.87727.03027.18327.33527.487160028.23628.38428.53128.67828.82428.970170029.68829.83029.97130.11230.25230.391180031.07931.21431.34931.48331.61731.750190032.40432.53332.66132.78932.91533.041200033.66033.78233.90334.02334.14234.260210034.84034.95335.06635.17735.28835.398220035.93236.03636.13936.24136.34136.441230036.92337.015钨铼3-钨铼25热电偶分度表 W3/25 参考端温度:0℃ 整10度mν℃010********00.0000.0980.1990.3050.4150.52810001.14501.27301.41401.55401.69601.84020002.60202.76102.92303.08703.25303.42030004.28604.46404.64404.82505.00805.19240006.12906.32006.51206.70506.89807.09350008.07708.27508.47508.67508.87509.07660010.08610.28910.49210.69510.89911.10370012.12412.32912.53412.73812.34313.14780014.17114.37614.58014.78514.98915.19490016.21116.41416.61716.81917.02117.223100018.22618.42618.62518.82419.02319.221110020.20620.40120.59720.79120.98621.180120022.14322.33422.52522.71522.90523.094130024.03324.22024.40624.59124.77624.961140025.87526.05726.23826.41826.59826.777150027.66627.84228.01828.19328.36828.542160029.40429.57529.74529.91430.08330.252170031.08531.24931.41331.57731.74031.902180032.70232.86033.01733.17433.33033.485190034.24834.39834.54734.69534.84334.989200035.70735.84835.98736.12636.26336.399210037.06337.19237.31937.44637.57137.694220038.29038.40438.51738.62838.73838.845230039.25639.453Pt100型热电阻分度表 Pt100 R(0℃)=100.00Ω 整10度电阻值℃010********0100103.9107.79111.67115.54119.4100138.51142.29146.07149.83153.58157.33200175.86179.53183.19186.84190.47194.1300212.05215.61219.15222.68226.21229.72400247.09250.53253.96257.38260.78264.18500280.98284.3287.62290.92294.21297.49600313.71316.92320.12323.3326.48329.64700345.28348.38351.46354.53357.59360.64800375.7378.68381.65384.6387.55390.48Pt10型热电阻分度表 Pt10 R(0℃)=10.00Ω 整10度电阻值Ω℃010********01010.3910.77911.16711.55411.9410013.85114.22914.60714.98315.35815.73320017.58617.95318.31918.68419.04719.4130021.20521.56121.91522.26822.62122.97240024.70925.05325.39625.73826.07826.41850028.09828.4328.76229.09229.42129.74960031.37131.69232.01232.3332.64832.96470034.52834.83835.14635.45335.75936.06480037.5737.86838.16538.4638.75539.048Cu50型热电阻分度表 Cu50 R(0℃)=50.000Ω 整10度电阻值Ω℃010********05052.14454.28556.42658.56560.70410071.473.54275.68677.83379.98282.134Cu100型热电阻分度表 Cu100 R(0℃)=100.00 整10度电阻值Ω℃010********0100104.29108.57112.85117.13121.41100142.8147.08151.37155.67159.96164.27:0℃ 整10度mν值6070809002.43602.85003.26603.68106.53906.93907.33807.73710.56010.96911.38111.79314.71215.13215.55215.97418.93819.36319.78820.21423.19823.62424.05024.47627.44527.86728.28828.70931.62932.04232.45532.86635.71836.12136.52436.92539.70340.09640.48840.87943.58543.96844.34944.72947.35647.72648.09548.46250.99051.34451.69752.04954.46654.807度:0℃ 整10度mν值6070809001.61901.90202.18902.48004.61804.93705.25905.58507.94108.28808.63708.98811.50111.86712.23412.60315.22515.60415.98416.33619.05919.44719.83520.22422.95823.35023.74224.13426.88327.27627.66928.06230.80731.19931.59031.98134.70735.09535.48235.86938.56238.94439.32639.70642.35242.72743.10143.47446.06046.42546.78947.152度:0℃ 整10度mν值6070809003.68304.32904.98305.64610.50111.22211.94912.68117.94218.71019.48120.25625.75426.54927.34528.14333.76734.57435.38236.19042.66243.47044.27845.08549.91150.71351.51352.31257.87358.66359.45160.23765.70066.47367.24568.01573.35074.10474.85775.608度:0℃ 整10度mν值6070809003.11503.64904.18604.72508.56009.11309.66710.22214.10814.66315.21715.77119.64020.19220.74321.29525.16125.71626.27226.82930.78231.35631.93332.51336.67137.28037.89338.51042.92243.56344.20744.85249.35449.98950.62151.24955.55356.15556.75357.34961.45962.03962.61963.19967.24067.81568.39068.964度:0℃ 整10度mν值6070809002.46702.90803.35703.81307.20707.71808.23508.75712.57213.13713.70714.281度:0℃ 整10度mν值607080900.3650.4320.5020.57301.10901.19001.27301.35601.96202.05102.14102.23202.88002.97403.06903.16403.84003.93804.03604.13504.83204.93305.03405.13605.85505.96006.06406.16906.91307.02007.12807.23608.00308.11408.22508.33609.12609.24009.35509.47010.28210.40010.51710.63511.46711.58711.70711.82712.67112.79212.91313.03413.88314.00414.12514.24715.09415.21515.33615.45616.29616.41516.53416.65317.47717.59417.71117.826度:0℃ 整10度mν值607080900.3630.4310.5010.57301.12401.20801.29401.38102.01702.11202.20702.30402.99703.09903.20103.30404.04004.14704.25504.36305.13305.24505.35705.47006.27306.39706.50706.62507.46107.58307.70507.82708.69708.82308.95009.07709.98010.11110.24210.37411.30711.44211.57811.71412.67312.81212.95013.08914.06614.20714.34714.48815.47515.61615.75815.89916.88717.02817.16917.31018.29218.43118.57118.71019.67719.81419.95120.08721.003度:0℃ 整10度mν值607080900.0060.0110.0170.0250.1070.1230.1400.1590.3170.3440.3720.4010.6320.6690.7070.74601.04801.09501.14301.19201.56001.61701.67401.73202.16402.23002.29602.36302.85502.92803.00303.07803.62603.70803.79003.87304.47404.56204.65204.74205.39105.48705.58305.68006.37406.47506.57706.68007.41407.52107.62807.73608.50408.61608.72708.83909.63409.74809.86309.97910.79010.90711.02411.14111.95912.07612.19312.31013.12413.23913.35413.470端温度:0℃ 整10度mν值607080900.8450.99401.14401.45102.41502.58102.74902.91904.14104.32004.50004.68205.97606.16406.35206.54107.88108.07408.26808.46109.82410.02010.21510.41111.77911.97412.16912.36413.72314.91614.10914.30215.64115.83116.02016.20917.51917.70417.88918.07419.34919.52919.70919.88821.12521.30021.47421.64722.84423.01223.18023.34724.50224.66524.82724.98826.10026.25726.41326.56827.63827.78827.93828.08729.11529.25929.40329.54630.53030.66830.80630.94331.88232.01432.14532.27533.16733.29133.41533.53834.37834.49534.61134.72635.50635.61435.72135.82736.54036.63736.73336.829考端温度:0℃ 整10度mν值607080900.6440.7650.88801.01501.98802.13702.29002.44503.59003.76103.93504.11005.37705.56305.75105.94007.28807.48407.68107.87909.27709.47909.68109.88311.30711.51111.71511.92013.35213.55713.76113.96615.39815.60115.80516.00817.42417.62517.82618.02619.41919.61619.81320.00921.37321.56621.75921.95123.28323.47123.65923.84625.14525.32825.51125.69326.95627.13427.31227.48928.71528.88829.06129.23330.41930.58730.75330.91932.06332.22432.38432.54333.63933.79233.94534.09735.13535.27935.42335.56636.53536.66836.80136.93337.81637.93738.05638.17438.95139.05539.15839.258100.00Ω 整10度电阻值Ω60708090123.24127.08130.9134.71161.05164.77168.48172.17197.71201.31204.9204.48233.21236.7240.18243.64267.56270.93274.29277.64300.75304.01307.25310.49332.79335.93339.06342.18363.67366.7369.71372.7110.00Ω 整10度电阻值Ω6070809012.32412.70813.0913.47116.10516.47716.84817.21719.77120.13120.4920.44823.32123.6724.01824.36426.75627.09327.42927.76430.07530.40130.72531.04933.27933.59333.90634.21836.36736.6736.97137.2710.000Ω 整10度电阻值Ω6070809062.84264.98167.1269.259=100.00 整10度电阻值Ω60708090125.68129.96134.24138.52。

热电偶原理及其分度表的应用

热电偶原理及其分度表的应用

热电偶原理及其分度表的应用1. 热电偶原理热电偶是一种基于热电效应的温度测量仪器,由两种不同金属导线组成。

热电偶的原理是基于两种金属导线在温度变化时产生的热电势差。

当两种金属导线的接触点处于不同温度环境下时,由于两种金属导线的热电势差不同,会形成一个闭合回路。

通过测量这个闭合回路的热电势差,可以间接测量温度。

2. 热电偶的组成热电偶由两种不同金属导线组成,常用的金属有铜、铁、镍、铬等。

这两种金属导线的接触点处于测量温度的位置,称为测点。

通常将与温度测量无关的那一段金属导线称为冷端,以保持其在一个恒定温度下。

3. 热电偶的原理当两种金属导线的接触点处于不同温度环境下时,由于两种金属的热电势差不同,会形成一个闭合回路。

这个热电势差可以通过热电偶表(冷端与测点之间的两段导线)来测量。

热电偶表可以根据热电势差的变化来确定温度的变化。

4. 热电偶分度表的应用热电偶分度表是通过实验测量得出的热电势差和温度之间的关系表格。

它可以用于将热电偶的热电势差转化为对应的温度值。

通过查阅热电偶分度表,可以准确得到特定的热电势差对应的温度。

由于不同种类的热电偶具有不同的热电势差-温度关系,因此需要选择正确的分度表来进行测量。

常用的热电偶分度表有K型、J型、T型等。

在实际应用中,我们需要根据测量温度的范围和要求来选择合适的热电偶和相应的分度表。

5. 热电偶分度表的示例下面是K型热电偶的分度表示例,用于将热电势差转化为温度值的参考:热电势差(mV)温度(℃)0.000 -200.00.515 -150.01.073 -100.0 1.928 -50.03.554 0.06.203 50.09.208 100.013.448 150.018.900 200.0通过这个示例表格,我们可以看到不同热电势差对应的温度。

在实际测量中,可以通过测量到的热电势差查阅分度表,从而得到精确的温度值。

6. 总结热电偶是一种基于热电效应的温度测量仪器,利用两种不同金属导线在温度变化时产生的热电势差来测量温度。

热电偶热电阻双向分度表

热电偶热电阻双向分度表

热电偶热电阻双向分度表查询
最全面的电子分度表
涵盖了60年代至今的多种分度表,包括Pt10,Pt100,Pt500,Pt800,Pt1000,Cu10,Cu50,Cu100,G53,BA1,BA2共11种热电阻的分度表,以及Its-1990中的全部热电偶(R、S、N、B、K、E、J、T共8种热电偶)的分度表。

全量程高精度
所有的传感器(包括热点偶和热电阻)均可以在其全部范围内换算,不留任何死角。

温度精确0.001℃,阻值精确到0.001Ω,电压精确到0.001mV。

不是单纯的换算出来的数据以三位小数的格式显示,而是换算结果的确精确到该。

双向可逆换算
目前几乎所有的热点偶分度表都能实现双向运算,因为its-90中的正函数和逆函数的拟和系数均已经明确且公开。

同时实现了热电偶和热电阻可逆不发散换算。

即你用a通过软件求出b,用b做输入,软件将计算出a。

这样的循环进行无数次,软件也不会离开a、b这两个值,实现了迭代收敛。

在线查询功能
本软件提供了安卓版的同时,还提供了在线实时查询版本。

IOS版,Windows版正在测试中...即日即将上线,敬请期待!
后期增加功能
后期将增加NI分度号的查询功能
各版本地址
在线查询版地址:/fenduhao.html(点击可连接至该网址)
安卓版下载地址:/downloads/app/ITS-90_1_3.apk(点击可连接至该网址)
IOS版下载地址:正在测试中...
Windows版下载地址:正在测试中...。

常用热电偶分度表完整

常用热电偶分度表完整

常用热电偶分度表(可以直接使用,可编辑实用优秀文档,欢迎下载)铂铑10-铂热电偶(S型)分度表(ITS-90)镍铬-镍硅热电偶(K型)分度表铂铑30-铂铑6热电偶(B型)分度表镍铬-铜镍(康铜)热电偶(E型)分度表铁-铜镍(康铜)热电偶(J型)分度表铜-铜镍(康铜)热电偶(T型)分度表目录第一章绪论 (1)第二章总体设计方案12.1 实现的功能12.2 总体思路 (2)第三章硬件系统设计 (2)3.1 温度传感器及调理电路 (2)3.1.1 热电偶工作原理23.2 热电偶的选型 (3)3.2.1 J型电偶 (4)3.2.2 E型电偶 (4)3.2.3 K型电偶 (4)3.2.3 N型电偶 (5)第四章 LabVIEW的软件设计 (5)4.1 前面板设计 (5)4.2 框图程序设计 (6)4.2.1 数据采集模块 (7)4.2.2 数据转换模块 (7)第五章实验结果与分析 (8)5.1实验结果95.2 实验分析9第六章小结9参考文献10附录1 热电偶温度表程序图11附录2 实验电路图11第一章绪论虚拟仪器的技术基础是计算机技术,核心是计算机软件技术。

LabVIEW使用了“所见即所得”的可视化技术建立人机界面,提供了许多仪器面板中的控制对象,如表头、旋钮、开关及坐标平面图等。

所谓虚拟仪器就是以计算机作为仪器统一的硬件平台,充分利用计算机的运算、存储、回放、调用、显示及文件管理等智能化功能,同时把传统仪器的专业化功能和面板控件软件化,使之与计算机结合构成一台从外观到功能都完全与传统硬件仪器相同,同时又充分享用了计算机智能资源的全新仪器系统。

与传统仪器相比,它的最大特点就是把由仪器生产厂家定义仪器功能的方式转变为由用户自己定义仪器功能,满足多种多样的应用需求。

由于虚拟仪器的测试功能、面板控件都实现了软件化,任何使用者都可通过修改虚拟仪器的软件来改变它的功能和规模,这充分体现了“软件就是仪器”的设计思想。

热电偶分度表

热电偶分度表

50 3.047
60 3.683
70 4.329
80 4.983
90 5.646
热 电 动 势 mV 9.787 10.501 11.222 11.949 12.681
13.419 14.161 14.909 15.661 16.417 17.178 17.942 18.710 19.481 20.256 21.033 21.814 22.597 23.383 24.171 24.961 25.754 26.549 27.345 28.143 28.943 29.744 30.546 31.350 32.155 32.960 33.767 34.574 35.382 36.190 36.999 37.808 38.617 39.426 40.236 41.045 41.853 42.662 43.470 44.278 45.085 45.891 46.697 47.502 48.306 49.109 49.911 50.713 51.513 52.312 53.110 53.907 54.703 55.498 56.291 57.083 57.873 58.663 59.451 60.237 61.022 61.806 62.588 63.368 64.147 64.924 65.700 66.473 67.245 68.015 68.783 69.549 70.313 71.075 71.835 72.593 73.350 74.104 74.857 75.608 76.358 — — — — — — — — —
40 2.058 7.457
50 2.585 8.008
60 3.115 8.560
70 3.649 9.113
80 4.186 9667

热电偶分度表

热电偶分度表

热电偶分度表是什么?热电偶分度表,这种测温工具对于我们来说是比较少见的。

就算我们偶尔看见到也把它当作水表看待。

热电偶分度表是一个测量热度的表,由0度到100度,它的数值在表上显示都有所不同的。

它的读数也是很讲究的与其他表读数不同的。

它的数值会跟着不同热度进行自动跳值。

工作原理两种不同成份的导体(称为热电偶丝材或热电极)两端接合成回路,当接合点的温度不同时,在回路中就会产生电动势,这种现象称为热电效应,而这种电动势称为热电势。

热电偶就是利用这种原理进行温度测量的,其中,直接用作测量介质温度的一端叫做工作端(也称为测量端),另一端叫做冷端(也称为补偿端);冷端与显示仪表或配套仪表连接,显示仪表会指出热电偶所产生的热电势。

使用方法热电偶分度表读法是把表中热电动势对应的行和列的温度相加,即为该热电动势对应的温度。

(1)首先仔细地观察热电偶分度表就可以看到:热电偶分度表的行:从第四行第二列起为100度的整数倍的温度下对应的热电动势,而第三行起是0到90度温度下对应的热电动势。

热电偶分度表的列:从第二列起为0度到90度温度下对应的热电动势。

(2)读数例如表中第三行第三列中的热电势为0.055mv,它所在行为0到90度温度下的热电势,它所在的列为10度对应的热电动势,所以把热电动势0.055mv对应的行温度0"加上"列温度10即10度即为热电势0.055mv对应下的温度。

再举例第八行第四列中的热电势为4.432mv,它所在行为500到590度温度下的热电势,它所在的列为20度对应的热电动势,所以把热电动势对应的行温度500度"加上"列温度20度即520度即为热电势4.432mv对应的温度。

热电偶分度表的基本介绍和使用方法上面都描述出来了。

热电偶分度表

热电偶分度表

热电偶分度表是一种测量温度的仪器,它结合了热电偶技术和分度表技术,可以实现精确的温度测量。

热电偶分度表是一种复合仪器,其结构包括热电偶、表盘和分度表。

热电偶由两种不同的金属片组成,其中一片金属片接触待测物体,另一片金属片接触固定温度,根据金属片之间的温度差,热电偶将变化的温度信号转变成电信号,传送到分度表上,分度表上的指针会根据电信号的变化而指向相应的温度值。

热电偶分度表的优势在于其精度高、测量范围广、使用方便等。

另外,它也具有良好的抗干扰能力,不受外界环境的影响,也不会受到热电偶的老化等影响,可以确保精确测量温度。

热电偶分度表可以用于世界各地各种行业的温度测量,如石油、冶金、食品、制药、实验室等。

它可以用来测量液体、气体、固体表面以及液体内部温度,还可以用来测量蒸汽压力、空气湿度等,可以说它在工业上有着广泛的应用。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

什么是热电偶分度表
什么是热电偶:
热电偶属于接触式温度测量仪表是工业生产中最常用的温度检测仪表之一。

其特点为测量精度高。

因热电偶直接与被测对象接触,不受中间介质的影响。

测量范围广。

常用的热电偶从-50~+1600℃均可连续测量,某些特殊热电偶最低可测到-269℃(如金铁镍铬),最高可达+2800℃(如钨-铼)。

构造简单,使用方便。

热电偶通常是由两种不同的金属丝组成,而且不受大小和开头的限制,外有保护套管,用起来非常方便。

热电偶是一种感温元件, 它能将温度信号转换成热电势信号, 通过与电气测量仪表的配合, 就能测量出被测的温度。

热电偶测温的基本原理是热电效应。

在由两种不同材料的导体 A 和 B 所组成的闭合回路中 , 当A 和 B 的两个接点处于不同温度 T 和 To时, 在回路中就会产生热电势。

这就是所谓的塞贝克效应。

导体 A 和 B 称为热电极。

温度较高的一端 (T 〉叫工作端 ( 通常焊接在一起 );温度较低的一端 (To 〉叫自由端 ( 通常处于某个恒定的温度下〉。

根据热电势与温度函数关系。

可制成热电偶分度表。

分度表是在自由端温度 To=00C 的条件下得到的。

不同的热电偶具有不同的分度表。

在热电偶回路中接入第三种金属材料时, 只要该材料两个接点的温度相同, 热电偶所产生的热电势将保持不变,即不受第三种金属接入回路中的影响。

因此, 在热电偶测温时, 可接入测量仪表, 测得热电势后, 即可知道被测介质的温度。

常用热电偶可分为标准热电偶和非标准热电偶两大类。

标准热电偶是指国家标准规定了其热电势与温度的关系、允许误差、并有统一的标准分度表的热电偶,它有与其配套的显示仪表可供选用。

非标准化热电偶在使用范围或数量级上均不及标准化热电偶,一般也没有统一的分度表,主要用于某些特殊场合的测量。

从理论上讲, 任何两种导体都可以配制成热电偶, 但实际上并不是所有材料都能制作热电偶, 故对热电极材料必须满足以下几点:热电偶材料受温度作用后能产生较高的热电势, 热电势和温度之间的关系最好呈线性或近似线性的单值函数关系;能测量较高的温度, 并在较宽的温度范国内应用, 经长期使用后, 物理、化学性能及热电特性保持稳定;要求材料的电阻温度系数要小, 电阻率高, 导电性能好, 热容量要小;复现性要好, 便于大批生产和互换, 便于制定统一的分度表;机械性能好, 材质均匀;资源丰富, 价格便宜。

为了保证热电偶可靠和稳定地工作对热电偶有如下要求:组成热电偶的两个热电极的焊接必须牢固;两个热电极彼此之间应很好地绝缘,以防短路;补偿导线与热电偶自由端的连接要方便可靠;保护套管应能保证热电极与有害介质充分隔离。

标准化热电偶,按IEC国际标准生产。

热电偶的分度号有主要有S、R、B、N、K、E、J、T等几种。

其中S、R、B属于贵金属热电偶,N、K、E、J、T属于廉金属热电偶。

S分度号的特点是抗氧化性能强,宜在氧化性、惰性气氛中连续使用,长期使用温度1400℃,短期1600℃。

在所有热电偶中,S分度号的精确度等级最高,通常用作标准热电偶;
R分度号与S分度号相比除热电动势大15%左右,其它性能几乎完全相同; B分度号在室温下热电动势极小,故在测量时一般不用补偿导线。

它的长期使用温度为1600℃,短期1800℃。

可在氧化性或中性气氛中使用,也可在真空条件下短期使用。

N分度号的特点是1300℃下高温抗氧化能力强,热电动势的长期稳定性及短期热循环的复现性好,耐核辐照及耐低温性能也好,可以部分代替S分度号热电偶;
K分度号的特点是抗氧化性能强,宜在氧化性、惰性气氛中连续使用,长期使用温度1000℃,短期1200℃。

在所有热电偶中使用最广泛;
E分度号的特点是在常用热电偶中,其热电动势最大,即灵敏度最高。

宜在氧化性、惰性气氛中连续使用,使用温度0-800℃;
J分度号的特点是既可用于氧化性气氛(使用温度上限750℃),也可用于还原性气氛(使用温度上限950℃),并且耐H2及CO气体腐蚀,多用于炼油及化工; T分度号的特点是在所有廉金属热电偶中精确度等级最高,通常用来测量300℃以下的温度。

由于热电偶的材料一般都比较贵重(特别是采用贵金属时),而测温点到仪表的距离都很远,为了节省热电偶材料,降低成本,通常采用补偿导线把热电偶的冷端(自由端)延伸到温度比较稳定的控制室内,连接到仪表端子上。

必须指出,热电偶补偿导线的作用只起延伸热电极,使热电偶的冷端移动到控制室的仪表端子上,它本身并不能消除冷端温度变化对测温的影响,不起补偿作用。

因此,还需采用其他修正方法来补偿冷端温度t0≠0℃时对测温的影响。

在使用热电偶补偿导线时必须注意型号相配,极性不能接错,补偿导线与热电偶连接端的温度不能超过100℃。

冷端温度补偿器的型号应与热电偶的型号相符,并在规定温度范围内使用; 冷端温度补偿器与热电偶连接时极性不能接错; 根据补偿器的平衡点温度调整仪表起始点,使指针批示在平衡点温度; 具有自动补偿机构的显示仪表不安装补偿器;补偿器必须定期检查和检定。

热电偶是工业上最常用的温度检测元件之一。

其优点是:
①测量精度高。

因热电偶直接与被测对象接触,不受中间介质的影响。

②测量范围广。

常用的热电偶从-50~+1600℃均可边续测量,某些特殊热电偶最低可测到-269℃(如金铁镍铬),最高可达+2800℃(如钨-铼)。

③构造简单,使用方便。

热电偶通常是由两种不同的金属丝组成,而且不受大小和开头的限制,外有保护套管,用起来非常方便。

1.热电偶测温基本原理
将两种不同材料的导体或半导体A和B焊接起来,构成一个闭合回路,如图2-1-1所
示。

当导体A和B的两个执着点1和2之间存在温差时,两者之间便产生电动势,因而在
回路中形成一个大小的电流,这种现象称为热电效应。

热电偶就是利用这一效应来工
作的。

2.热电偶的种类及结构形成
(1)热电偶的种类
常用热电偶可分为标准热电偶和非标准热电偶两大类。

所调用标准热电偶是指国家
标准规定了其热电势与温度的关系、允许误差、并有统一的标准分度表的热电偶,它
有与其配套的显示仪表可供选用。

非标准化热电偶在使用范围或数量级上均不及标准
化热电偶,一般也没有统一的分度表,主要用于某些特殊场合的测量。

标准化热电偶我国从1988年1月1日起,热电偶和热电阻全部按IEC国际标准生产,并指定S、B、E、K、R、J、T七种标准化热电偶为我国统一设计型热电偶。

(2)热电偶的结构形式为了保证热电偶可靠、稳定地工作,对它的结构要求如下:
①组成热电偶的两个热电极的焊接必须牢固;
②两个热电极彼此之间应很好地绝缘,以防短路;
③补偿导线与热电偶自由端的连接要方便可靠;
④保护套管应能保证热电极与有害介质充分隔离。

3.热电偶冷端的温度补偿
由于热电偶的材料一般都比较贵重(特别是采用贵金属时),而测温点到仪表的距离都很远,为了节省热电偶材料,降低成本,通常采用补偿导线把热电偶的冷端(自由端)延伸到温度比较稳定的控制室内,连接到仪表端子上。

必须指出,热电偶补偿导线的作用只起延伸热电极,使热电偶的冷端移动到控制室的仪表端子上,它本身并不能消除冷端温度变化对测温的影响,不起补偿作用。

因此,还需采用其他修正方法来补偿冷端温度t0≠0℃时对测温的影响。

在使用热电偶补偿导线时必须注意型号相配,极性不能接错,补偿导线与热电偶连接端的温度不能超过100℃。

下面是热电偶的分度表:。