2M测试仪说明书

2M测试仪说明书
2M测试仪说明书

目录

1. 概述...................................... 错误!未定义书签。

2. 主菜单.................................... 错误!未定义书签。

菜单选择................................. 错误!未定义书签。

3. 测试设置.................................. 错误!未定义书签。

Tx/Rx1/DATA端口设置 ..................... 错误!未定义书签。

CLK/RX2端口设置........................... 错误!未定义书签。

其它设置................................. 错误!未定义书签。

4. 专业设置.................................. 错误!未定义书签。

帧信息设置............................... 错误!未定义书签。

同步信息设置............................. 错误!未定义书签。

ABCD设置................................. 错误!未定义书签。

5. 测试结果.................................. 错误!未定义书签。

常规测试结果............................. 错误!未定义书签。

直方图.................................... 错误!未定义书签。

时隙分析结果............................. 错误!未定义书签。

6. 档案管理.................................. 错误!未定义书签。

测试设置存取............................. 错误!未定义书签。

测试结果存取............................. 错误! 未定义书签。

7. 仪表设置.................................. 错误!未定义书签。

显示设置................................. 错误!未定义书签。

打印设置................................. 错误!未定义书签。

时间设置................................. 错误!未定义书签。

8. 应用举例.................................. 错误!未定义书签。

2Mbit/s 通道停业务误码测试。............... 错误!未定义书签。

2M/s 通道开业务误码测试.................. 错误!未定义书签。9. 主要技术指标.............................. 错误!未定义书签。

1. 概述

2M数字传输性能分析仪,适用于数字传输系统的工程施工、工程验收及日常维护测试。其性能可靠稳定、功能齐全、体积小巧,采用大屏幕中文显示,操作简洁容易。

2M数字传输性能分析仪可对2Mbit/s接口数字通道进行测试,具有两个

2Mbit/s接口,可同时对两条通道进行测试。

?寸2Mbit/s接口数字通道可进行以下项目的测试。

中断业务误码测试

在线误码测试

比特误码、编码误码、帧误码、CRC误码、E比特误码性能测试

图案滑动测试

时钟滑动测试

信号丢失、AIS告警、帧远端告警、复帧远端告警、帧失步、图案失步告警测试线路信号频率测试

话路通道信号电平、频率测试

信令状态显示

话路通道内容显示

话路通道忙闲显示

直通方式

环路延时测试

自动保护倒换时间测试

信号波形模板测试

时隙内容分析

、、误码性能分析

双路2Mbit/s同时检测,双向监听

2. 主菜单

主菜单显示如图5,在以下几种情况下可进入主菜单。

⑴开机。

⑵在其他菜单中按ESCAPE键一次或多次。

初範目当前结果档幸言理

仪表i翅兀机连接软件升级

图主菜单

菜单选择

在主菜单下有以下(标记显示)菜单可选择。

测试设置

用光标移动键将光标移到测试设置处,按ENTER键进入测试设置界面,用于设置测试项目及参数。光标移到测试设置处时也可用F键直接选择测试设置界面中的常规测试、通过测试、时延测试、音频测试、APS测试等工作方式。

测试结果

用光标移动键将光标移到测试结果处,按ENTER键进入测试结果界面,用于显示各种测试结果。光标移到测试结果处时也可用F键直接选择测试结果、时隙分析、监听、模板等界面。

档案管理

用光标移动键将光标移到档案管理处,按ENTER键进入档案管理-设置存取

界面。光标移到测试结果处时也可用

F

键直接选择档案管理-设置存取界面或档案

管理-结果存取界面。 仪表设置

用光标移动键将光标移到仪表设置处,按ENTER 键进入仪表设置界面,用于 设置仪表的一些辅

助参数。光标移到仪表设置处时也可用 F 键直接选择仪表设置界

面内的子菜单或版本信息界面。 连接PC 机

用光标移动键将光标移到 PC 机连接处,按ENTER 键或F1键关闭连接PC 机 功能;按F2键

打开连接PC 机功能,液晶显示器的状态显示区同时显示 卩T 。

软件升级

用光标移动键将光标移到 软件升级处,按ENTER 键或F1键进入仪表内部 软件升级功能说明界

面。

3. 测试设置

测试设置由多屏界面组成,用于设置仪表测试项目及参数

Tx/Rx1/DATA 端 口设置

图是接口方式为 2Mbit/s 和同向64kbit/s (接口方式为同向 64kbit/s 时,相应选项 自动无效)时的界面,左边表示发送端口的设置,右边表示接收端口的设置,各栏 代表的含义如图所示。

可當规测试IM 过测闻吐让河试旦頓测试

JUblt/s

P013L G. 'iO3(?b£^)

"9-1

同向

Ml

FCM31

"9丄

I 同

图Tx/Rx1端口设置

3.1.1测试设置界面选择

把光标移到 界面说明 栏,可选择 上一页、下一页 或专业设置。测试设置由

Tx/Rx1DATA 端口设置、Rx2端口设置、其它设置和打印设置 4个界面组成。

3.1.2工作方式

把光标移到工作方式栏,有以下可选项目 常规测试: 常规方式用于误码、滑码、通道内容等测试项目 通过测试:选择通过方式。

音频测试: 选择音频测试方式,对所选择时隙通路进行音频测试(频率、电平) 。

时延测试: 选择时延测试方式,对整个 2Mbit/s 通路、n x 64kbit/s 及V 接口通路 进行环路时延测试。

APS 测试: 用于测试系统的自动保护倒换时间

3.1.3发送(Tx )、接收(Rx )关系 把光标移到 接收 栏,有以下可选项目。 Rx : 发送(Tx )和接收(Rx )的参数相互独立,可以进行分别设置。

Rx=Tx

接收(Rx )的参数与发送(Tx )的参数相同,当改变 Tx 时,Rx 自动跟着变

■式凶U1Q ◎

界面说明 接口方式 信号形式 数据端口

时钟方式

测试图案-①■ 信

号码型

时隙选择

接口方式 信号形式 数据端口

信号端口

测试图案 ②■ 信号

码型 时隙选择

① 图案极性 ② 图案极性

图Tx/Rx1端口设置说明

发送

工作万式 接收

.总

化。

3.1.4 接口方式

把光标移到接口方式栏,有以下可选项目,接收(Rx)的接口方式自动与发送(Tx)的接口方式保持一致。

2Mbit/s :用于测试2Mbit/s 数字通路

3.1.5 信号形式

把光标移到信号形式栏,有以下可选项目

非帧:选择非帧信号形式。

PCM31:选择31 路信号形式。

PCM31CRC:选择31路信号形式并且带有CRC-4校验功能。

PCM30:选择30 路信号形式,第16 时隙用于传送信令。

PCM30CRC:

选择30路信号形式,第16时隙用于传送信令并且带有CRC-4校验

功能。

3.1.6 数据端口

把光标移到数据端口栏,有以下可选项目

(75Q ):选择75 Q非平衡接口。

(120Q ): 选择120 Q平衡接口。

3.1.7 时钟方式

把光标移到时钟方式栏,有以下可选项目

内部时钟:发端信号时钟选择内部时钟振荡器。

时钟提取:发端时钟选择从收端输入信号中提取的时钟。

外部时钟:发端时钟选择外部时钟输入口输入的时钟信号,外部时钟信号可以

是或s 信号。

3.1.8 测试图案

把光标移到Tx 的 测试图案 栏,有以下可选项目

2e6-1:

选择仪表发送或接收信号中的测试图案为 2e6-1。

2e9-1: 选择仪表发送或接收信号中的测试图案为 2e9-1o ITU —规定的图案。 2e11-1: 选择仪表发送或接收信号中的测试图案为 2e11-1o 2e15-1:

选择仪表发送或接收信号中的测试图案为 2e15-1o 2e20-1: 选择仪表发送或接收信号中的测试图案为 2e20-1 o 2e23-1:

选择仪表发送或接收信号中的测试图案为 2e23-1 o

WORD

选择仪表发送、接收信号中的测试图案为

8bit 人工码。选择 WORD 后,

F1、F2键分别定义为置1、置0。用*或卜将光标移至要修改的某一位下,按

F1

选择该位置1,按F2选择该位清0。 在线测试:用于2Mbit/s 的误码在线测试, 此时Bit Error 'Pattern Slip 、Pattern Loss

测试功能无效。

3.1.9图案极性

把光标移到的图案极性栏,有以下可选项目 同向:

图案同向,接收或发送ITU —规定的图案。

反向: 图案反向,接收或发送ITU —规定反向的图案。 Rx 的图案极性也可以由仪表自动搜寻,参照“

测试图案” 3.1.10信号码型

把光标移到的 信号码型 栏,有以下可选项目

HDB3: 选择HDB3,输入输出信号为 HDB3编码。 AMI : 选择AMI ,输入输出信号为 AMI 编码。

3.1.11时隙选择

把光标移到的

时隙选择 栏,有以下可选项目

所有时隙:

按F2选择所有时

隙。信号形式为PCM30CRC 或PCM30 时选择了 30个时隙作为测试通道; 信号形式为 PCM31或PCM31CRC 时

选择31个时隙作为测试通道。

n*64k : 按F1选择n*64k,选择任意时隙作为测试通道。

对时隙选择栏进行操作后,进入时隙设置界面,如图。

图时隙设置

时隙设置方法:

用光标移动键将光标移至欲选择的时隙号下,按F1选择该时隙,时隙号显示黑色。按F2清除该时隙,时隙号显示反白。按F3选择所有时隙,按F4清除所有时隙。对于选中的时隙,测试图案被插入。

空闲时隙码设置方法:

把光标移至空闲时隙码要修改的某一位中,按F1选择该位置1,按F2选择该位清0。

CLK/RX2端口设置

如图所示,各栏代表的含义如图所示

也対伽丿L WQJ I i軋型如

I绷试丘直CL恥皿云矗I

图CLK/RX2端口设置

工^作方

信号形式

数据端口

信号端口

信号码型

图CLK/Rx2 端口设置说明

3.2.1 工作方式把光标移到的工作方式栏,有以下可选项目。

时钟输入:CLK/Rx2 端口作为外时钟输入口使用,此时信号形式、信号码型栏无效。

2M测试:CLK/RX2端口作为第二个2Mbit/s测试用,可对线路进行在线测试;

同时也可兼作外时钟输入口使用。

3.2.2 信号形式把光标移到信号形式栏,有以下可选项目。

非帧:选择非帧信号形式。

PCM31:选择31 路信号形式。

PCM31CRC:选择31路信号形式并且带有CRC-4校验功能。

PCM30:选择30 路信号形式,第16 时隙用于传送信令。

PCM30CRC:

选择30路信号形式,第16时隙用于传送信令并且带有CRC-4校验

功能。

3.2.3 数据端口

把光标移到数据端口栏,有以下可选项目

(75Q ):选择75 Q非平衡接口。

(120Q ): 选择120 Q平衡接口。

3.2.4 信号端口

把光标移到的信号端口栏,有以下可选项目。

终接:信号输入端口阻抗为75 Q或120 Q

桥接:信号输入端口阻抗为高阻。

325信号码型

把光标移到的信号码型栏,有以下可选项目

HDB3:选择HDB3,输入输出信号为HDB3编码。

AMI: 选择AMI,输入输出信号为AMI编码。

其它设置

时撫试1200奔Lp月呼日巴时Q吩dpi秒

测试时農19天阿吋1汾冇秒

色动重复弟田

误码插入

把光标移至误码插入栏,可选择以下选项:

无:没有任何误码插入。

Bit ERR 选择比特误码插入,比特误码插入可选择单次或率,率的范围为 1 x 10-2 ?1 x 10-6。

PAT Slip选择图案滑动插入,插入选择为单次。

FAS ERR选择帧误码插入,插入选择为单次、连续2、连续3、连续4。

选择误码插入后,若插入次数选择为单次或连续2、连续3、连续4,则按一次ERR INJ,就相应插入1个或2个、3个、4个误码,并在状态显示区显示丨秒。若插入选择为率,则按一次ERR INJ误码插入就开

误码;封、B it ER?単发1

FAS L DES

2IOVLO/01

频率拉悄|2D48mtHDDOQ}k| |十切00_ Oppin |

如图所示:

因I丄■虫T下一页I于业i艮专.

始,并在状态显示区显示,再按一次ERR INJ误码插入停止,皿图标消失。

告警插入

把光标移至告警插入栏,可选择以下选项:

无:没有任何告警插入。

AIS:选择告警信号指示插入。

FAS Loss选择帧失步告警插入。

RA: 选择远端帧告警插入。

MRA:选择远端复帧告警插入。

频率拉偏

把光标移至频率拉偏栏,可选择以下选项:

标准频率:恢复到标准频率。

正拉偏:设置频率偏差为正值。

负拉偏:设置频率偏差为负值。

加1:频率拉偏值加上1。

减1:频率拉偏值减去1。

加10:频率拉偏值加上10O

减10:频率拉偏值减去10O

加100:频率拉偏值加上100O

减100:频率拉偏值减去100O

加1000:频率拉偏值加上1000 O

减1000:频率拉偏值减去1000 O

定时测试

把光标移至定时测试栏,可选择以下选项:

关闭:关闭定时测试功能。

打开:开启定时测试功能,并在状态显示区显示

设置:开启定时测试功能,设定定时测试时间,并在状态显示区显示

关机休眠:仪表进入关机休眠状态,此时仪表关机,POWER灯闪烁,待所设置

的测试启动时间到来时,仪表自动开机测试。

定时测试功能开启后,在状态显示区会显示易,待所设置的测试启动时间到来时,仪表自动开机测试。

测试时长

把光标移至测试时长栏,可选择以下选项:

关闭:关闭测试时长功能。

打开:开启测试时长功能。

设置:开启测试时长功能,设定测试时长。

测试时长功能开启后,仪表测试到设定的时长后,会自动停止测试。

自动重复

把光标移至自动重复栏,可选择以下选项:

关闭:关闭自动重复功能。

打开:开启自动重复功能。

自动重复功能开启后,仪表测试到设定的时长后,会自动开始新的测试。

4. 专业设置

当Tx/Rx1DATA端口设置界面的接口方式为2Mbit/s 、并且发送的信号形式为

有帧结构时,可进行本项设置。

在测试设置界面中,按专业设置功能键,进入本项设置。

帧信息设置

如图,把光标移至要修改的某一位中

按F1选择该位置1,按F2选择该位清0

帧信息设置中可修改的位和相应的缺省值如下: 同步帧Si: 非同步帧Si: 非同步帧A : 缺省值为“ 1 ” 缺省值为“ 1 ” 缺省值为“ 0” 复帧同步帧y : 缺省值为“ 0”

图帧信息设置

★ 注意:不正确的设置会产生误码或告警,一般测试时请按缺省值设置。

同步信息设置

ABCD 设置

如图,把光标移至要修改的某一位中按 F1选择该位置1,按F2选择该位清0, 或直接按F3选择全1。

如图,把光标移至要修改的某一位中按 或直

接按F3选择全1。

F1选择该位置1,按F2选择该位清0,

丄页I 下項砖顾II

1S AB.'J TS AiO TS Ak.-.b IS ABC.

oa LUI Jb 1111 1111 L7 1111 24 25 llll

1111

02 LUI 】D

111! LU 1111 26 1L11 03 LUI ]L 1111

1111 57 1111

04 Lil J 12 1L1J 20 111! 2S L ILI C£ L1IJ J3 LL1J 21 mi 西 Llll ce Llll 】LLU Z2 LILI 30 LLLL

err Llll 15 LIU Z3 llll 3L Llll

丄顶[下顶用业皿

图ABCD 设置

注意:每组ABCD 的值不能为全“ 0”。

5. 测试结果

常规测试结果

当Tx/Rx1DATA 端口设置界面的工作方式选择常规测试或通过测试时,测试结果 为常规测试结果显示方式。

误码测试结果

误码结果显示如图,其各部分显示的 含义如下:

① 测试结果说明、测试时间 ② 测试已进行的时间、剩余的时间

③ 本次测试主要设置参数 ④ 测试结果内容。

2-IOVLO/01 10>:20 49

匚呷屯&川冗古書误崗丨

当前整吳 血1貉旱 盪冈“min 二上丄空亦

3D/OC :tJl!OL

2rlS-l

KJ131CfiC | HUt3

EJik

C D .1- ERJ ?

n W Cade iHH

0 PAS HfiH

D

%PA5 0 匚就肥?R

D

K CKC E 恋 0 已bit

0 U Bfcit 1KH u

PAT Slip □

I 屛皂袒定I 丄£ I F 史I 直

图告警测试结果

测试结果内容:

SIG Loss 信号丢失告警发生的秒数(秒) AIS:

AIS 告警指示信号)告警发生的秒数(秒)

FAS Loss 帧失步告警发生的秒数(秒) PAT Loss 图案失步发生的秒数(秒) RA: RA 帧远端告警)发生的秒数(秒) MRA :

MRA (复帧远端告警)发生的秒数(秒)

Bit ERR % Bit ERR 比特误码个数 比特误码率 图误码测试结果

Code ERR

% Code ERR

编码误码个数 编码误码率 FAS ERR 帧误码个数 % FAS ERR 帧误码率

CRC ERR CRC-4误码个数 % CRC ERR CRC-4误码率

% Ebit ERR E 比特误码率

5.1.2告警测试结果 告

警结果显示如图:

叱■址匕fiC | HUT

src L OSE (S ) 0 ALE(S ) 0

FAS L OSE (S ) 0 弘G) 0 .A . 1 i 1 - - .-■ )

D IRA(s)

PMi Lass

D

:屛思袒定I 丄顶I 下项

测试结果内容:

Ebit ERR E 比特误码个数

PAT Slip 图案滑动个数

匚]中川曉吉書gg]

当前占丄昱眾码早愛诫俎0小1 H:13:騎

线路分析结果

线路分析结果显示如图:

i」m:川曉吉手些賂分祈]

当前里黑下迈討罕壷1571丽in :士師

图线路分析结果

测试结果内容:

Clock +Slip当前秒时钟正滑动数

Clock -Slip当前秒时钟负滑动数

Clock +Cpp时钟正滑动累计数

Clock -Cpp时钟负滑动累计数

Level +V(V:线路信号脉冲正幅度值

Level -V(V): 线路信号脉冲负幅度值

Level Vp-p(V):线路信号脉冲峰-峰值

Rx Freq RCV(Hz)线路信号频率当前值

Rx Freq RCV(ppm)线路信号频率当前相对值

Rx Freq max(Hz)线路信号频率最大值

Rx Freq max(ppm): 线路信号频率最大相对值

Rx Freq min(Hz)线路信号频率最小值

Rx Freq min(ppm): 线路信号频率最小相对值

综合分析结果

线路分析结果包括分析、分析、停业务接收方向分析、开业务接收方向分析,如图:

匚呼¥占樂果艾丄於祈]

当翦土黑下至羿:负乔win :■tkj.士師

分析内容:

ES(s)误码秒数

% ES(s)误码秒比

SES(s)严重误码秒数

% SES(s)严重误码秒比

AS(s)可用时间秒数

% AS(s:可用时间秒比

UAS(s)不可用时间秒数

% UAS(s:不可用时间秒比

分析内容:

ES(s)误码秒数

% ES(s)误码秒比

SES(s)严重误码秒数

% SES(s)严重误码秒比

AS(s:可用时间秒数

% AS(s:可用时间秒比

UAS(s)不可用时间秒数

% UAS(s:不可用时间秒比

BBE背景差错块

% BBE:背景差错块率

停业务接收方向分析:

ES(s:)误码秒数

%ES(s:)误码秒比

SES(s:)严重误码秒数

%SES

严重误码秒比

(s:)

AS(s):可用时间秒数

%AS(s):可用时间秒比

UAS(s:)不可用时间秒数

%UAS

不可用时间秒比

(s):

开业务接收方向分析:

ES(s:)误码秒数

%ES(s:)误码秒比

SES(s:)严重误码秒数

%SES

严重误码秒比

(s:)

AS(s):可用时间秒数

%AS(s):可用时间秒比

UAS(s:)不可用时间秒数

%UAS

不可用时间秒比

(s):

直方图

当Tx/Rx1/DATA 端口设置界面工作方式选择常规测试或通过测试时,Rx1 端口和DATA端口的测试结果可利用直方图方式显示。

在常规测试结果界面中,按直方图功能键进入直方图分析,如图:

在直方图显示中水平轴代表时间,垂直轴表示当前所选择类型的事件数值,

上的垂直线段表示该时刻对应的事件的数值,辅助信息为主要告警的直方图,

SIG Loss AIS FAS Loss PAT Loss告警,粗线表示有告警。

误码或告警类型:按F1或F2选择希望分析的误码或告警的类型

分辨率:直方图中水平时间轴上的最小显示单位

按▲键增大分辨率单位

按”键减小分辨率单位

▲:光标

按*键光标向右移动

按F3键显示上一页直方图内容

按F4键显示下一页直方图内容

光标信息-时间:光标所在位置的时间,或光标所在位置时间段的起始时间

光标信息-结果:光标所在位置的误码数或告警秒

时隙分析结果

当Tx/Rxl/DATA端口设置界面工作方式选择常规测试或通过测试时,并且Rx的信

号形式选择为有帧结构时,或CLK/RX2端口设置界面的信号形式选择为有帧结

构时,测试结果可选择时隙分析结果显示方式。

克方區1 『辨車:1杪

无祢甘息3T|fi]:2003/L(VCl 10120:05

Lit 11Kb.结黑: 1 ITT; ooi/o DI

Dl[下一r丄M :□血1

图分析结果

水平轴

包括JDBF

丄吹

1^11 id f2:H

在主菜单界面中,把光标移至测试结果栏,按时隙分析功能键进入本界面,参照

“菜单选择”。时隙分析测试不影响正在进行中的其它测试。

时隙分析结果包括时隙分析、 帧信息、同步信息和ABCD 信息,如图、图、图和图。

:屛兽血I 丄顶I 下项

时隙分析说明:

TS :时隙号

BIN :二进制表示时隙内容 HEX :十六进制表示时隙内容

TS

BIH

IS L-LN HEX

DO 10J03DD0 WO Ofl 00000000 00 01 10000000

30 09 ooftjoodo

00

02 10000000

ao L0 O OOJOOOD 00 03 10 JOODOO ao

]L

o mjoooo no 04 10 DM ODO SD lz K JQOOODD

ID

DE 10ODODOO 30 13 □OQOOODD OD □6 li OQODOO 町

14 D OCI.IQOO IJO

□7 11 000 DOO 8J 15 DOtJJOQOO

IJ0

图时隙分析

帧信息说明: 同步帧: 非同步帧: 复

帧同步帧:

C0011011,二进制表示奇帧内容 ilassssq 二进制表示偶帧内容

OOOOxyxx ,二进制表示复帧同步内容

崂应3012H型自动烟尘(气)测试仪作业指导书)

崂应3012H型自动烟尘(气)测试仪 操作与维护作业指导书 1 适用范围 1.1各种锅炉、工业炉窑的烟尘排放浓度、折算浓度和排放总量的测定。 1.2测试仪器配上油烟采样器,可以进行油烟采样。 1.3各类除尘设备效率的测定。 1.4烟道排气参数(动压、静压、温度、流速、标干流量等)的测定。 1.5烟气含氧量、空气过剩系数的测定。 1.6烟气含湿量的测定。 1.7烟气连续性测量仪器准确度的评估和校准。 1.8各种锅炉、工业炉窑的SO2/NO/CO/NO2/H2S/CO2等有害气体的排放浓度、折算浓度、和排放总量的测定。 1.9其他适用场合。 2编制依据 《崂应3012H型自动烟尘(气)测试仪使用说明书》 《环境监测仪器设备操作与维护保养规则》 3采样前准备 3.1 滤筒前清理和称重:用铅笔将滤筒编号,在105~110℃烘箱内烘烤1小时,取出放入干燥器中冷却至室温。用感量0.1㎎天平称量,放入专用容器中保存。 3.2 干燥剂的装填 将高效气水分离器底盖旋开,加入约3/4 体积的具有充分干燥能 力的变色硅胶(颗粒状),然后将干燥筒盖旋紧,应保持不漏气。

3.3 检查仪器功能 确认电源为交流220V 后,连接好电源线,打开电源开关,工作 指示灯亮,检查显示器、键盘、采样泵等是否正常。 3.4 开机 确认连接正常后,打开仪器电源开关,面板上的工作指示灯点亮,测试仪进入初始状态,进行自检。自检结束后,自动进入主菜单。 3.5 参数设置 在主菜单状态,进入“①设置”菜单,可进行必要的参数设置, 包括日期、时间、测试类别、眼纹类型、大气压类别、皮托管系数、防倒吸功能。 3.6 采样布点 在主菜单状态,移动光标至“②布点”菜单,按“OK”键进入烟 道布点界面,按提示选择烟道类型,按”OK“键即可进入烟道类型设置界面。 3.7 工况测量 在主菜单状态,移动光标至“③工况”菜单,按“OK”键进入工 况测量界面,连接好气路及信号线,并将取样管置于空气中。选中“①自动调零”菜单,按“OK”键进入自动调零界面,当所有压力数值均回到零且保持不变时,按“OK”键结束调零。 4 采样 4.1 预测流速 将取样管插入烟道,全压测孔必须正对气流方向,密封烟道测孔,保证不漏气。进入“②预测流速”菜单,待每个测点的动压值基本稳

BTS-2002电池综合测试仪说明书

目录 1.前言 (2) 2.功能概述 (3) 3.仪器外观 (5) 4.接线方式 (6) 5.主功能菜单 (7) 6.电池静态参数测量模式 (8) 7.电池容量测量模式 (12) 8.单独充电模式 (14) 9.单独放电模式 (14) 10.程控电源模式 (14) 11.程控电子负载模式 (15) 12.电压与内阻表模式 (16) 13.仪器校准模式 (16) 14.读码功能(DS2502兼容码) (17) 15.仪器特性指标 (18)

前言 常见的可充电电池包含锂电池,镍镉电池,镍氢电池,以及密封铅酸蓄电池等。 其中,锂电池具有容量大,重量轻,循环次数高等特点,广泛应用于移动电话,PDA,数码相机,摄像机,笔记本电脑等领域,是目前最为先进的可充电电池。这里所指锂电池是成品锂电池包,由锂电芯(锂离子电芯或者锂聚合物电芯)加锂电池保护板组成。 镍镉电池是比较早应用的可充电电池,具有成本较低,低内阻,能够大电流放电的特点,至今在一些电动工具、电动车上面有广泛应用。 镍氢电池和镍镉电池类似,但是因为不含重金属,所以对环境的污染较小,目前在一些常见的消费类电子产品中应用广泛,已基本取代以前镍镉电池的应用领域。 小型密封铅酸电池,又称免维护铅酸电他,目前工艺成熟,目前主要应用在固定式后备电源场合,如不间断电源,应急照明灯等等场合。 针对这些可充电电池的生产检测需要,特研制了专用的可充电电池综合检测仪,本测试仪可以对电池的一些基本参数做一个定量的精确的测量,可以测量电池的开路电压,内阻,充电,放电性能,电池容量特别针对锂电池的功能还有过充电保护,过放电保护,过电流保护,短路保护等功能,并测出过相应的数值,极大的方便了电池的生产和售前售后服务工作。采用非常简单的几个步骤就可以直观的判断电池的性能和好坏,同时也具有快速筛选的功能,可以设定测量参数的上限和下限,可以容易的从一批电池成品中快速检测出不良电池,提高生产效率。另外,也附加了一些特别的功能,使之具有一些通用仪器设备的特征,扩大了设备的使用灵活性,以及具有应用范围广泛的特点。 此外,本测试仪可根据客户的需要提供软件升级服务,在基本型号的基础上,可以通过软件升级为可连接电脑的型号,可以通过电脑来设置和保存测试数据,自动记录测试结果。也可以通过电池条码来记录每块电池的测试数据,有利于生产质量的分析控制,产品追朔等等。另外,可以通过加装硬件升级模块来提高电压和内阻的测试精度上升一个数量级,来满足更苛刻的质量要求。

静电测试仪使用说明书

Hand-held static sensor locates and meas-ures static voltages, tests air ionizers.New from 3M,the 718 Static Sensor can help companies competing in the global high-tech marketplace prevent cost-ly losses due to electro static discharge (ESD) damage by playing a vital and valuable role in their own ESD control program. Easy to use,the hand-held 3M ?718 Static Sensor is designed to measure static voltages on objects and sur-faces arising from electrostatic charge buildups,and can help identify ESD trouble-spots — ensuring product relia-bility and customer satisfaction which translates into com-pany profits. As a bonus,when used in conjunction with the 3M TM Model 718A Air Ionizer Test Kit,the 718 can also be used to verify the operation of air ionizers.718 Static Sensor Features ? Small-size,lightweight,conductive plastic housing ? Membrane switches for Power,Range/Zero,and Hold functions. ? Digital,LCD (liquid-crystal) display is easy to read and updates quickly. ? Ranging system assists user in making quick and easy measurements ? Measurements accurate to 5% ? Output jack available for continuous measurements Convenient Size/Low Power Requirements The 718 is small enough to be carried in a pocket and weighs less than 5 oz. (142 g),including battery. The light-weight plastic housing is conductive,allowing a properly-grounded user to dissipate all electrostatic charges from the surface of the meter.Meter Functions The meter is equipped with three membrane switches which control different functions. The POWER switch turns the instrument on and off. The RANGE/ZERO button performs two functions; when pressed momentarily it switches between the two measurement ranges of 0-2,000 volts and 0-20,000 volts,and if held for longer than 3 seconds,it resets the voltage display to 0 volts. The HOLD button allows the user to freeze a measurement on the LCD for later review.Ranging System Included with the 3M 718 Static Sensor is a ranging system consisting of two light-emitting diodes (LEDs) which each emit a circular red light onto the surface being measured for static. When the two lights intersect and form a single focused light,the measurement distance is the prescribed 1 inch (2.54 cm). Accuracy The Model 718 Static Sensor is accurate to within ±5% of the displayed measurement,at a distance of one inch (2.54 cm) from the target. Accuracy will vary as the dis-tance between measured object and instrument changes from the one inch (2.54 cm) specification.Analog Output Jack The analog output jack located in the front of the unit pro-vides a convenient hook-up,via a 3/32 inch (2.5 mm)monophone jack,to a recorder/data acquisition console. The 3M 718 Static Sensor may then be used for remote monitoring or permanent recording of electrostatic voltage readings. 3M 718 Static Sensor Specifications Dimensions 0.85" (H) x 2.4" (W) x 4.15" (L) 2.2 cm (H) x 6.1 cm (W) x 10.5 cm (L)Weight 4.5 oz. (128 g) with battery Power Requirements One 9-volt alkaline battery Measurement Ranges 0 – 2 kV Low Range 0 - 20 kV High Range V oltage Display 3) digit liquid crystal display V oltage Output 1/1000 of measured voltage @ low range 1/10,000 of measured voltage @ high range Distance Indicator LED targets. Aligned targets indicate 1 in. (2.54 cm) measurement distance Measurement Accuracy Within 5% of actual voltage Certifications UL,C-UL,CE,CB-scheme,NOM 3 718 Static Sensor 718A Air Ionizer Test Kit 718 Range Finder Unfocused 718 Range Finder at 1" away 3M 718 Static Sensor 1 2 3

科电中威KDJF-2010多通道数字式局部放电检测仪使用说明书

使用说明书 武汉科电中威电气有限公司 WuHan KeDian ZhongWei Electric Co.,Ltd

一、仪器基本概述 1、型号:KDJF-2010 2、产品适用范围:KDJF-2010多通道数字式局部放电检测仪适用于各种电压等级和容量的变压器、互感器、发电机、避雷器、套管、GIS、电容器、电力电缆、开关及其它高压电气设备的局部放电检测,在线监测。 二、产品外型图 三、产品执行标准 ?GB/T16927 -----------《高电压试验技术》 ?IEC60270 -------------《局部放电测量》 ?GB/T7354 ------------《局部放电测量》 ?GB1094 --------------《电力变压器》 ?IEC6067.11 ----------《干式变压器》 ?GB1207 --------------《电压互感器》 ?GB1208 --------------《电流互感器》 ?DL417 ---------------《电力设备局部放电现场测量导则》 ?GB12706.4 ----------《电力电缆附件试验要求》

?GB/T3048.12 -------《电线电缆电性能试验方法局放试验》 ?DL/T 846.4-2004 ---《高电压测试设备通用技术条件第四部分局部放电测量仪》 四、产品结构 1、显示屏:15英寸真彩色TFT液晶显示屏,工业级高亮度;显示分辨率:1024×768;4位数码管显示电压值。 2、外部接口:USB接口;电源接口;2路信号输入口;接地端子;外同步信号输入端子;RJ45接口;RS232接口。 3、外形尺寸:长×宽×高(540×460×320)mm。 4、重量:18kg。 五、主要技术指标 1、测量通道:独立2通道。 2、可测试品的电容量范围6pF~250μF。 3、检测灵敏度:0.1pC。 4、采样精度:12bit;采样速率:20M/S。 5、显示工作方式 (1)显示方法:椭圆——正弦——直线 (2)触发同步方式:分内外触发方式,内触发为仪器电源同步触发,50Hz;外触发为同步试验电源工作频率,50~400Hz内任意频率。 (3)外触发同步信号输入电压:10~200V,输入功率<1伏安。 (4)信号相位判定:椭圆显示为极坐标方式,正弦显示为正弦波方式,其显示图形的起点为试验电源的零点,其显示图形的长度为试验电源的一个周期,外触发同步方式下系统真实准确地显示了试验电源的周期、相位。 6、时间窗:相位大小任意选择,可动态放大显示时间窗,两个时间窗可分别或同时开。 7、滤波频带:3dB低频端频率f L分10、20、40kHz档,3dB高频端频率f H分80、200、300kHz档, f L和f H可灵活任意组成各种滤波通带。 8、信号放大器: (1)增益调节:分增益粗调和增益细调,增益粗调分6档,档间增益差20dB(10倍),误差±1dB调节;增益细调范围>20dB。 (2)放大器正负极性响应不对称性:<1dB。 9、局放信号测量:可在连续、放大等显示工作方式下测量局放信号,误差±5%(以满量程计)。 10、具有数据存储,回放功能,具有打印功能,生成标准试验报告。 11、工作环境温度:-10~45℃,相对湿度:≤95%。 12、电源AC220V;频率50Hz;功率300W。

崂应3012H型自动烟尘(气)测试仪作业指导书

崂应3012H型自动烟尘(气)测试仪操作 作业指导书 崂应3012H型烟尘采样仪操作规程 一、仪器名称:崂应3012H型动压平衡自动跟踪等速烟尘采样仪 二、适用范围:各种锅炉、工业炉窑的烟尘浓度、烟尘、烟气排放量的测定。各类除尘设备、除尘效率的测定,含湿量、含氧量、过量空气系数的测定,油烟浓度和排放量的测定。 三、具体步骤及注意事项 1、仪器连接方法: ①仪器选择干燥地方放置,打开仪器右侧门,可见配接板。 ②将采样管分别与配接板接嘴上的色标—红、黄、白、黑一一对应,用Φ8×1的硅胶管对接。 ③测尘时主气路管联接:采样管——干燥瓶下嘴——干燥瓶上嘴——仪器进气口——仪器出气口——泵; 测气时:采气管——干燥瓶——仪器测气口——仪器出气口——泵; 测湿时:采气管——仪器测湿口——仪气湿出气口——干燥瓶——泵; ④电源线接法:输入电源接220V,输出电源接抽气泵。 ⑤测烟气温度时,仪器插上烟气测温探头。 ⑥安装滤筒:拧开采样管头部锁紧环,用镊子夹起滤筒小心对正放入滤筒托内,旋紧采样管压紧环。注意:安装采样嘴“弯钩”时,保持皮托管位于滤筒座右侧,采样嘴口与白色标记皮托管口朝向一致,以保证采样管与仪器配接板色标一致。 2、确认连接正常后,打开仪器电源开关显示屏出现仪器自检准备,自检完成后,自动进入菜单。通过仪器下方的(选择键)、(移位键)、确认键、取消退出键对主菜单上的各项功能进行操作,并按照仪器对用户的提示进行每项操作。 3、采样现场一般环境条件较差,通常为高空作业,注意人身安全和仪器安全。 4、采样管插入烟道后,要有棉纱团堵塞采样孔,特别是正压管道,更要注意防止有害气体喷出伤人,堵住烟道采样孔,还可以防止气流扰动对采样带来的影响。 5、手持采样管和堵塞采样孔时要戴防护手套,防止烫伤。 6、现场接电源时,请勿用仪器试电,确认220V交流电后接通仪器电源,防止误接其它工业用电,损坏仪器。 7、对静电干扰的烟道,电源一定要有安全地。 8、干燥剂(硅胶)变色约三分之二时,应及时更换,以保证干燥能力。更换硅胶后,干燥瓶上盖要旋紧,保证气路的气密性。 9、采样管与仪器配接板要正确连接,保证正常采样和防止传感器损坏。

检测仪使用说明书

检测仪使用说明书 一.概述 核酸蛋白检测仪、紫外检测仪是液湘色谱仪中的一种紫外检测装置,核酸蛋白检测仪、紫外检测仪是根据生命科学的发展对于现代色谱仪器的要求而改进设计的一种新型紫外检测仪。该仪器在创新方面的主要特点为: 1.该仪器除配有输出10mV记录仪信号外,还配有输出适合计算机积分仪的输口,这 样很方便构成色谱工作站系统。(可同时进行计算机和记录仪信号输出,亦可省去记录仪) 2.该仪器的数字显示设计为固定光吸收,A显示计算机用和可变量程光吸收A显示记 录仪用两种可选模式,这样可方便于规范化读数(特别是可应用于药品生产的GMP 工艺规范化管理),同时亦可根据科研需要进行可变量程的高灵敏度读数,这样可方便于对低浓度样品检测。 3.该仪器采用新型进口IP28光电倍增管和改进型电路结构,使仪器工作更为稳定可 靠。 该仪器配有上层析柱、恒流泵、部分收集器等等,即组成一套完整的液色湘色谱分离分析系统。它可应用于现代生物学研究,药物测定、农业科研、化工、食品及医疗单位对具有紫外吸收的样品作定量分析。本仪器主要元器件均采用进口,仪器全部采用LED数字显示,使用方便。 二.主要技术性能 (1)核酸蛋白检测仪提供波长:254nm、280nm。 (2)紫外检测仪提供波长:220nm、254nm、280nm、340nm。 (3)量程范围:0~100%T、0~2A、0~1A、0~0.5A、0~0.2A、0~0.1A、0~0.05A。 (4)流式样品池:容积100微升、光程3毫米。 微量样品池:容积30微升、光程10毫米。 (5)记录仪输出:10mV (6)积分仪输出:0.1A/mV (7)数显模式:固定A量程读数(0~2.0A);可变A量程读数(0~2.0A、0~1.0A、0~0.5A、0~0.2A、0~0.1A、0~0.05A)。 (8)量程在0.05A档时:噪音≦0.002A。 (9)工作环境温度:0℃~35℃。 (10)仪器可连续工作。 (11)电源:220VAC±10%50HZ。 (12)单体外形尺寸:280×180×158(mm)。 (13)主机重量:5㎏。 三.工作原理 从光源发出的光经狭缝,滤色器聚焦到样品池上,此单色光通过样品池射到光电倍增管的光阴极面上,使光束由于样品浓度不同所引起透光强度的变化转换成光电流变化,此光电流经放大器放大,并输入到对数转换器、使透光率T转换成光吸收A输出即A=lgT/1=ε·CL式中ε为待测样品的摩尔消光系数,C为样品浓度,采用摩尔/升单位,L为光程,用厘米作单位。根据上式只要测出了A、L和ε就可求出样品浓度C。若从放大器直接输入到记录仪,则在记录仪上绘出的是样品透光率T变化的图谱,若从对数转换器输入到记录仪上,在记录仪上绘出的是样品光吸收变化的图谱。 四.仪器结构 核酸蛋白检测仪、紫外检测仪是单光路结构,由紫外检测器、和记录仪部分组成现将其构造分别说明如下: 1.紫外检测仪: 它由光源、干涉滤色片、样品池、光电倍增管、放大和对数板、低压板和高压板等组成。面板上有四氟塑料管的进样口和出样口,A调零以及调节“光量”大小旋(光

3250综合测试仪操作说明

1、前言 1、1产品概说. 3259 变压器综合测试系统乃是一部全功能自动化测试的零件量测分析仪器, 本量测仪器 设计的主要宗旨为本着十多年来的经验与成果累积, 为解决目前日益蓬勃发展的电子业因人 工效率以及产品品质所带来之烦恼, 满足电子行业提高工作效率及提升产品之品质需要,其性能质量已达国际水准。 本测量仪器所包含之量测功能有电感、电容、交流电阻、阻抗 (L、C、R、Z), 直流电阻 (DCR), 变压器相位 (PH), 及圈数比 (Turn-Ratio), 漏电感(Lk), 脚位短路(PS), 平衡 (Balance) 等测试功能,为生产线及品管QC提供最完善的测试功能。 经由本量测仪器之内部控制之自动式及可程序之量测功能, 以提供在低成本下有高精度、便利、快速及可靠之测试, 其提供了上下界限比较及分组测试, 测试频率及测试电压之选择控制、加载校正(Load)、多频扫瞄测试功能、设定数据储存记忆功能、单机扫描测试功能、另外可藉由扫描控制器做全功能完全扫描测试, 内存扩充接口做数据存取控制, RS-232接口做数 据传输与统计分析功能, 打印机接口功能将测试结果打印, 藉由操纵接口HANDLER经由外部 触发仪器量测并可将此量测结果藉由此接口送至外部,做为反应零件处理设备. 本仪器亦有提供重迭电流(I≦1A)产生器, 可配合重迭电流产生器量测线圈重迭电流电感量。 多用途可变的测试装置, 人性化的键盘设计, 引导式的操作接口, 超大型液晶显示面板, 按键锁住和密码保护功能等等措施都使本仪器在操作上能方便容易的使用, 并有保护功能使 测试结果被清楚的显示于显示器上。 3259基本量测准确度为0.1%, 校正时以校正用之专属量测装置 (可选购) 并输入简单之量测参数. 使用者只需在程序中提供开路 (Open) 及短路 (Short) 的条件即可非常简单快速完成校正作业. 仪器随时需要外部测试或导线延伸测试时, 注意需使用正确的4接点连接测试. 且在高 频量测时需考虑测线的高频响应.

局部放电测试仪校准装置

JFD-401 局放仪校验装置使用说明书 一、概述 按照DL/T846.4-2004《局部放电测量仪》、GB7354-2003《局部放电测量》、JJG(机械)145 -93《局部放电检测装置》检定规程的要求,检定局放仪需用仪器有:示波器、正弦信号发生器、脉冲发生器、双脉冲发生器、频率计、电压表、电流表、电容电桥、兆欧表等。上述仪器中除脉冲发生器、双脉冲发生器外,均为常规测试仪器。而脉冲发生器要求电压覆盖范围宽,脉冲波形满足特殊规定要求;双脉冲发生器需输出脉冲时延可调的双脉冲,固均需专门研制。本校准系统的核心即为一台高性能的校准脉冲发生器和一台双脉冲发生器,校准脉冲发生器可以满足局放仪视在放电量测量线性度误差、正负脉冲响应不对称误差、开关换档误差、检测灵敏度等主要检定项目检定的要求;双脉冲发生器可以满足局放仪低重复率脉冲响应误差、脉冲分辨时间测量、脉冲频率测量、数字式局放仪等检定项目检定的要求。另配的校准回路箱提供屏蔽的校准回路,使检定时干扰水平大大降低,保证检定的顺利进行以及检定的测量精度。 二、原理和结构 JFD-401 校准系统分为四大部分:JFD-401C校准脉冲发生器、JFD-401J 积分系统、JFD-401S双脉冲发生器和JFD-401H校准回路箱。校准脉冲发生器可输出幅值大范围可调、波形符合要求的校准脉冲。双脉冲发生器可输出脉冲频率可调、两脉冲间隔脉冲时延可调、波形符合要求的校准脉冲并可进行脉冲计数、积分系统用于以积分方式检定局放仪方波发生器。校准回路箱可以调节试品电容及耦合电容,使其满足检测阻抗的调谐范围。上述四部分分别装在独立的金属机箱里,保证屏蔽效果良好。 三、技术参数 JFD-401C 校准脉冲发生器的技术指标如下: 1、校准脉冲上升时间:<60nS 2、校准脉冲电压幅值可调范围:粗调档分0db,-20db,-40db三档;细调档可从1.0V至110V无级调节;实际上可以做到从10mV至100V连续可调。 3、校准脉冲电容档:20pF,50PF,100pF,500pF,1000PF,2000PF 共六档。

继电保护测试仪说明书

微机继电保护测试仪 使 用 说 明 书

目录 目录 (1) 第一部分微机继电保护测试仪使用说明 (3) 第一章装置特点与技术参数 (4) 第二章装置硬件结构 (6) 第三章单机操作模块功能说明 (8) 第四章外接PC机操作说明 (21) 第二部分继保软件操作说明 (21) 第五章软件操作方法简介 (22) 第六章交流试验 (24) 第七章直流试验 (32) 第八章状态系列 (34) 第九章谐波叠加试验 (38) 第十章频率及高低周试验 (41) 第十一章功率方向及阻抗试验 (45) 第十二章同期试验 (49) 第十三章整组试验Ⅰ和Ⅱ (54) 第十四章距离和零序保护 (59) 第十五章线路保护 (64) 第十六章阻抗特性 (70) 第十七章差动保护 (73) 第十八章 6-35KV微机线路保护综合测试 (80) 附录1:外接电脑串行通信口的设置 (85) 附录2:插接U盘等设备时设备驱动安装方法 (87) 附录3:各种继电器的试验方法 (87)

第一部分 继保使用说明

第一章装置特点与技术参数 第一节主要特点 ◆标准的4相电压3相电流输出具有4相电压3相电流输出,可方便地进行各种组合输出进行各种 类型保护试验。每相电压可输出120V,电流三并可输出120A,第4相电压Ux为多功能电压项,可设为4种3U0或检同期电压,或任意某一电压值的情况输出。 ◆单机操作方便单机由方便灵活的旋转鼠标通过大屏幕液晶显示屏进行操作,全部中文显示。可 完成现场大多数试验检定工作,可对各种继电器及微机保护进行检定,并可模拟各种复杂的瞬时性、永久性、转换性故障进行整组试验。开机即可使用,操作方便快捷。 ◆双操作方式,联接电脑运行通过Windows平台上的全套中文操作软件,可进行各种大型复杂 及自动化程度更高的校验工作,可方便地测试及扫描各种保护定值,可实时存贮测试数据,显示矢量图,绘制故障波形,联机打印报表等。 ◆软件功能强大可完成各种自动化程度高的大型复杂校验工作,如三相差动试验、厂用电快切、 备自投试验、线路保护检同期重合闸等,能方便地测试及扫描各种保护定值,进行故障回放,实时存储测试数据,显示矢量图,联机打印报告等。 ◆开关量接点丰富7路接点输入和2对空接点输出。输入接点为空接点和0~250V电位接点兼容, 可智能自动识别。输入、输出接点可根据用户需要扩展。 ◆大屏幕LCD显示屏本机采用320×240点阵大屏幕高分辨率图形液晶显示屏,全部操作过程均在 显示屏上设定,操作界面和试验结果均汉化显示,显示直观清晰。 ◆自我保护采用合理设计的散热结构,并具有可靠完善的多种保护措施及电源软启动,和一定的 故障自诊断及闭锁功能。 ◆具有独立专用直流电源输出装置设有一路110V 及220V专用可调直流电源输出。 ◆性价比高属于跨专业联合设计产品,综合了多专业的先进科技成果。兼具大型测试仪的性能, 和小型测试仪的价位,具有很高的性能价格比。

3250综合测试仪操作说明

3250综合测试仪操作说明 1、前言 1、1产品概说. 3259 变压器综合测试系统乃是一部全功能自动化测试的零件量测分析仪器, 本量测 仪器设计的主要宗旨为本着十多年来的经验与成果累积, 为解决目前日益蓬勃发展的电子 业因人工效率以及产品品质所带来之烦恼, 满足电子行业提高工作效率及提升产品之品质 需要,其性能质量已达国际水准。 本测量仪器所包含之量测功能有电感、电容、交流电阻、阻抗 (L、C 、R 、Z), 直 流电阻 (DCR), 变压器相位 (PH), 及圈数比 (Turn-Ratio), 漏电感(Lk), 脚位短路(PS), 平衡 (Balance)等测试功能, 为生产线及品管QC 提供最完善的测试功能。 经由本量测仪器之内部控制之自动式及可程序之量测功能, 以提供在低成本下有高精度、便利、快速及可靠之测试, 其提供了上下界限比较及分组测试, 测试频率及测试电压 之选择控制、加载校正(Load)、多频扫瞄测试功能、设定数据储存记忆功能、单机扫描测 试功能、另外可藉由扫描控制器做全功能完全扫描测试, 内存扩充接口做数据存取控制, RS-232接口做数据传输与统计分析功能, 打印机接口功能将测试结果打印, 藉由操纵接口HANDLER 经由外部触发仪器量测并可将此量测结果藉由此接口送至外部, 做为反应零件处 理设备. 本仪器亦有提供重迭电流(I≦1A) 产生器, 可配合重迭电流产生器量测线圈重迭 电流电感量。 多用途可变的测试装置, 人性化的键盘设计, 引导式的操作接口, 超大型液晶显示面板, 按键锁住和密码保护功能等等措施都使本仪器在操作上能方便容易的使用, 并有保护 功能使测试结果被清楚的显示于显示器上。 3259基本量测准确度为0.1%, 校正时以校正用之专属量测装置 (可选购) 并输入简 单之量测参数. 使用者只需在程序中提供开路 (Open) 及短路 (Short) 的条件即可非常 简单快速完成校正作业. 仪器随时需要外部测试或导线延伸测试时, 注意需使用正确的4接点连接测试. 且在 高频量测时需考虑测线的高频响应. 1.2规格摘要 测定参数 : 第一测试参数 -- L、C 、R 、|Z |、Y 、△、△%、DCR 、Turn-Ratio 第二测 试参数 -- Q、D 、R 、θ 基本精度测定范围 : Basic 0.1%(1kHz/ 1V rms) : L C R Q D

局放测试仪说明书

GSJFY 局放测试仪 产品操作手册 福州亿森电力设备有限公司

尊敬的用户: 感谢您购买本公司GSJFY局放测试仪。在您初次使用该产品前,请您详 细地阅读本使用说明书,将可帮助您熟练地使用本仪器。 我们的宗旨是不断地改进和完善公司的产品,如果您有不清楚之处,请与公司售后服务部联络,我们会尽快给您答复。 注意事项 ●使用产品时,请按说明书规范操作 ●未经允许,请勿开启仪器,这会影响产品的保修。自行拆卸厂方概不负责。 ●存放保管本仪器时,应注意环境温度和湿度,放在干燥通风的地方为宜, 要防尘、防潮、防震、防酸碱及腐蚀气体。 ●仪器运输时应避免雨水浸蚀,严防碰撞和坠落。 本手册内容如有更改,恕不通告。没有武汉国电西高电气有限公司的书 面许可,本手册任何部分都不许以任何(电子的或机械的)形式、方法或以 任何目的而进行传播。

目录 一、概述 (4) 二、主要技术指标 (4) 三、系统工作原理 (7) 四、结构说明 (9) 五、操作说明 (11) 六、使用期限 (15) 七、售后服务 (16) 附一:校正脉冲发生器使用说明书 (18) 附二:局部放电试验中的局放和干扰图例 (20) GSJFY局放测试仪

一、概述 GSJFY局放测试仪是近年来新研制生产的又一新颖局部放电检测仪。广泛适用于变压器、互感器、高压开关、氧化锌避雷器、电力电缆等各种高电压电工产品的局部放电的测量,产品的型式试验,绝缘的运行监督等。 本仪器检测灵敏度高,试样电容复盖范围大,适用试品范围广,输入单元(检测阻抗)配备齐全,频带组合多(九种)。仪器经适当定标后能直读放电脉冲的放电量,指针式表头和数字式表头同时显示,指针式表头能按需要方便地选择对数刻度或线性刻度指示。 本仪器是电力部门、制造厂商和科研院所等单位广泛使用的实用的局部放电测试仪器。 二、主要技术指标 1.使用条件 (1)环境温度:0~40℃±2℃。 (2)相对湿度:80%以下。 (3)供电电源:220V±22V,50HZ。 (4)无剧烈震动和机械冲击。 (5)空气中不含有足以腐蚀仪器的灰尘和杂质。 (6)不应受强的电磁场干扰。

IXIA测试仪使用手册

IXIA测试仪使用手册 一、设备开机、关机 (一)开机 打开IXIA测试仪电源,等待设备启动完成,需将测试客户端IP设置为192.168.1.200,测试仪IP地址为192.168.1.100,开IxNetwork或IxLoad可连接测试仪表明设备完成开机。 (二)关机 在运行中输入mstsc进入远程桌面,连接到计算机192.168.1.100,在运行中输入shutdown.exe -s -t 3让设备在3秒内关闭,让系统自动关闭。 二、二三层测试配置(IxNetwork) 使用IxNetwork配置测试基本流程如下图所示。 (一)添加测试端口 点击标题栏中的 或Overview表页中的

连接192.168.1.100测试板卡 添加测试用端口

然后点击OK键,完成测试端口添加。 (二)配置端口、协议 启用测试端口Ping及ARP,如下图所示。 添加测试端口IP地址、网关,并使能端口,如下图所示,添加的网关地址需是实际存在的,可以是交换机的网关地址或测试端口对端IP地址。

(三)配置流量 选择配置流量。 Type of Traffic选项可选择Raw、Ethernet/vlan、IPV4分别对应原始报文流(需手动编辑,用来打广播包流)、二层流、三层流(需配置IP地址及网关),Bi-Directional表示流是双向流。 1、IPV4(三层流)

在设置好Type of Traffic、Traffic Mesh以及选择好端口后,点击添加Endpoint。点击NEXT,在Packet/QoS、Flow Group Setup、Frame Setup、Rate Setup保持默认配置。点击NEXT,进入Flow Tracking,选择Traffic Item选项。点击NEXT,在后续Protocol Behaviors、 Preview以及Validate中保持默认选项,同时检查配置的有效性。

烟尘烟气测试仪操作指引教材

锅炉烟气烟尘检测是一项较复杂的工作,要求检测人员熟练掌握仪器操作技能,不断丰富现场经验,编辑此锅炉烟气烟尘检测的简要流程,需要检测人员凭此在实际检测中不断摸索,不断完善。(表格中的数据只是举例,不作检测及计算参考) 1、检测仪器设备的准备和检查 1.1、滤筒前处理和称重 用铅笔将滤筒编号,在105~110℃的烘箱内烘烤1小时,取出放于干燥箱内冷却至室温,再用最小读数为0.0001g的天平称量,两次重量误差不超过0.5mm,放于专用容器中保存; 1.2、干燥剂的填装 将干燥筒密封盖旋开,加于约3/4体积的具有充分干燥能力的变色硅胶(颗粒状),然后旋紧密封盖; 1.3、取样管与主机的联接 1.3.1、主机面板上的两个“△P”接嘴用橡胶管(¢4×7)与取样管上的“皮托管接嘴”相 连,皮托管面向气流方向的连接到“+”端,背向气流方向的连接到“-”端; 1.3.2、干燥筒的出气嘴与面板上标有“烟尘”的接嘴用橡胶管(¢8×14,0.4米)相连,缓 冲筒的进气嘴用橡胶管(¢8×14,6米)与烟尘取样管的气路接嘴相连,干燥筒与缓冲筒橡胶管(¢8×14,0.4米)相连; 1.3.4、加装滤筒:记下滤筒编号,将滤筒装入取样管,旋紧压盖。

2、开机自检,进入主画面 确认连接好后,打开仪器电源开关,仪器进入初始状态,进行自检,稍等片刻,显示如下: 移动光标,选择相应菜单,按“确认”键执行。 3、参数设置 3.1、基本设置 移动光标至“1 进行必要的参数设置后,按“确认”键保存。

3.2、锅炉参数设置 3.2.1、移动光标至“2 画面直接显示的上一次进行采样的锅炉参数,如果本次采样的是同一个锅炉可不作修改,直接执行“4.读入” 3.2.2、执行“4 通过“上寻”与“下寻”可找到本次采样锅炉的标识,将储存的锅炉参数读入本次采

激光可吸入粉尘检测仪使用说明

执行标准: WS/T 206-2001《公共场所空气中可吸入颗粒物(PM10)测定方法——光散射法》 PC-3A型 激光可吸入粉尘检测仪 说 明 书

青岛骏康环保科技有限公司 用户须知 尊敬的用户,欢迎您使用青岛骏康环保科技有限公司生产PC-3A型激光可吸入粉尘检测仪。 本说明书是该仪器的使用说明,也是现场实际操作的必读手册!请您在使用该仪器之前,务必仔细阅读本说明书,以便用好此仪器,使其发挥应有的作用。如有不清楚之处,可与我公司联系;联系地址及电话详见每页页脚处的信息。

注: 1.本仪器不宜在具有油雾及酸雾等腐蚀性气体中工作。 2.不得将烟雾及高浓度颗粒物直接喷入传感器取样口,以免污染光学系统。 3.谨防震动,摔打、碰击。 4.本仪器自销售之日起保修期一年(人为损伤除外)。

PC-3A型激光可吸入粉尘检测仪 一、仪器简介 该仪器以国家环保标准WS/T 206-2001《公共场所空气中可吸入颗粒物(PM10)测定方法——光散射法》为依据由我公司自主研发的新一代智能化测量仪器。 该仪器性价比较高,主要适用于一般性生产车间、公共场所、疾病控制中心、卫生监督和环境监测等部门等,可以实时快速测量空气中可吸入颗粒物浓度,深受广大用户欢迎。 二、工作原理 该仪器是由组装在一起的感应器和数据处理器组成。感应器是本仪器数据采集的关键部件,该部件的原理是将激光束经过一组非球面镜变成一束功率密度均匀分布的细测量光束,在光束轨迹的侧前方为一前焦点落在光束轨迹上,后焦点落在一光电转换器上的散射光收集透镜组,当一流动的取样空气通过激光束与散射光收集镜组的前焦点交汇处时,空气中的尘埃粒子发出与其物理尺寸相对应的散射光,散射光经过光学透镜收集,在后焦点处由光电转换器件接受并转换成相应的电信号。 感应器的采样气体进口设在仪器的顶端位置。采集空气的动力源是一无刷直流风机。数据处理器则将感应器收集到的电信号经过电子切割器将大粒子分离掉以后,由微处理器进行湿度、质量浓度等换算。结果由LED显示器显示、储存或打印。 三、仪器特点 1.利用光散射法原理测量,灵敏度高,稳定性好,测量精度高; 2.交直流两用,按键清晰全面,操作简单; 3.测试速度快,噪声低,重量轻,携带方便;

甲醛检测仪使用说明书

美国INTERASCAN 4160型甲醛检测仪 使用说明书

美国INTERASCAN 4160型甲醛检测仪简介美国INTERASCAN 4160型甲醛检测仪是专门用于检测空气中甲醛含量的直读式仪器,仪器有内置采样泵,检测元件是长寿命、高可靠性的电化学传感器。 操作时,样气进入传感器,气体浓度以ppm为单位直接显示。 仪器的基本部件是:传感器、电池、电路。电路包括:零点补偿、传感器偏置、放大器、采样泵和液晶显示器等。 传感器原理 美国INTERASCAN 4160型甲醛检测仪采用三电极传感器有一系列优点,INTERASCAN传感器电解质是不活动的类似于闪光灯和镍镉电池中的电解质。所以不需要考虑电池损坏或酸对仪器的损坏。游离的电解质减少将清除不希望的传感器噪音干扰,特别是低浓度测量需要高放大倍数时,传感器有一个密封的储气室,这不仅使传感器寿命更长,而且消除了参比电极污染的可能性,不象二电极传感器需要空气来操作,INTERASCAN 传感器可用于厌氧环境。 INTERASCAN传感器是高灵敏度的检测器,根据气体的类型,其灵敏度大于扩散性传感器的50~200倍。可以测量非常低的值,这对于低浓度气体测量是重要的条件。 操作原理 美国INTERASCAN 4160型甲醛检测仪采用电化学电压型传感器,是一种电化学气体检测器,它是在控制扩散的条件下运行的。样气的气体分子被吸收到电化学敏感电极,经过扩散介质后,在适当的敏感电极电位下气体分子发生电化学反应,这一反应产生一个与气体浓度成正比的电流,这一电流转换为电压值并送给仪表读数或记录仪记录。 技术参数: 显示:液晶数字显示 测量范围:0~19.99ppm 最小读数:0.01ppm 不确定度:0.03ppm (0~0.5ppm) 体积:178×102×225mm3 重量:2Kg

安规综合测试仪使用说明资料

MS2000/MS2000A安规综合测试仪使用说明书目录 1.工作人员操作安全手册及测试前准备说明 1.1 一般规定 1.2 维护和保养 1.3 测试工作站 1.4 操作人员规定 1.5 测试安全程序规定 1.6 安全要点 2.安规测试简介 2.1 测试的重要性 2.2 交流接地电阻测试 2.3 绝缘电阻测试 2.4 耐压测试 2.5 泄漏电流测试 3.产品综述 3.1 产品简介 3.2 产品特点 4.技术参数 4.1 交流耐压 4.2 直流耐压 4.3 绝缘电阻 4.4 接地电阻 4.5 泄漏电流 5.其他功能 5.1 安全保护功能 5.2 记忆功能 5.3 工作模式保存 5.4 接口功能(可选) 5.5 实时时钟 5.6 显示 5.7菜单操作界面 键盘.58 6.仪器操作设置说明中文菜单1 .6. 6.2 按键的功能 6.3 界面说明 7.仪器面板结构排列 7.1 仪器前后面板示意图

7.2 面板各部分说明 7.3 接线操作说明 8.安全操作规程 9.随机附件 一、工作人员操作安全手册及测试前准备说明 一般规定.11a.使用测量仪前,请认真阅读该用户手册,按用户手册要求使用。 b.测量过程中,严禁操作人员身体触及仪器带电部位和被测负载壳体,谨防触电! c.拆接测试仪后面板上的接线时,请务必在切断电源,再行操作! d.进行绝缘和耐压测试时,被测负载与大地和周围物体应保持良好的电气隔离。 尤其注意:被测负载与流水线体应保持良好的电气隔离。 e.测量仪器必须安全接地。 注:本手册若有不详尽之处,请直接与本公司总部联系。 1.2维护和保养 使用者的维护.1.12为了防止意外触电的发生,请不要自行打开机器的盖子。如果机器有异常情况发生,请寻求我公司或指定的经销商给予维护。 1.2.2定期维护 本安全性能综合测试仪、输入电源线、测试线、测试插座和相关附件等每年至少要有一次仔细检验和校验一次,以保证使用者的安全和机器的精确性。如果测试仪是用于生产现场或其它恶劣条件下,必须缩短检验和校验周期。 1.2.3使用者的修改 使用者不得自行更改机器的线路或零件,如被更改,机器的保证则自动失效且本公司不负任何责任。使用未经本公司认可的零件或附件也不予保证。如发现送回检修的机器被更改,我公司会将机器的电路或零件修复回原来设计的状态,并收取维护费用。 1.3测试工作站 1.3.1位置选择 工作站的位置选定必须安排在一般人员非必经的处所,使非工作人员远离工作站。如果因为生产线的安排而无法做到时,必须将工作站与其它设施隔开,并且特别标明“测试工作站”。如果工作站与其他作业站非常接近时,必须特别注意安全的问题。在测试时必须标明“危险!测试执行中,非工作人员请勿靠近!”。 输入电源2.3.1. 安全性能综合测试仪必须有良好的接地,作业前务必将地线接妥,以确保人员安全。测试站的电源必须有单独的开关,装置于测试站的入口显眼处并予特别标明,让所有人都能辨别那是测试站的电源开关。一旦有紧急事故发生,可以立即关闭电源,再进行处理事故。 1.3.3工作场所 尽可能使用非导电材质的工作桌工作台。操作人员和待测物之间不得使用任何金属。操作人员的位置不得有跨越待测物去操作或调整测试机器的现象。测试场所必须随时保持整洁、干净,不得杂乱无章。不使用的仪器和测试线请放固定位置,一定要让所有的人员都能立即分出何者为正在测试的物件、待测物件和已测物件。测试站及其周边之空气中不能含有可燃气体及腐蚀性气体。不得在易燃物品的旁边使用安全性能综合测试仪。 操作人员规定41.1.4.1人员资格 安全性能综合测试仪在错误的操作时可能造成误触电,这足以造成人员的伤害,这种伤害甚至是有生命危险的,因此必须由训练合格的人员使用和操作。