天津西青疾控中心暖通设计

合集下载

科技住宅暖通系统设计介绍——以天津海河金茂府项目为例

科技住宅暖通系统设计介绍——以天津海河金茂府项目为例

Abstract: in the mainstream technology residential buildings in recent years, and introduces the differences among different developers in some design schemes. Through the introduction of cold and heat source selection, air conditioning/heating system design, ventilation system design and automatic control design, the readers will have a preliminary understanding of the HVAC design of science and technology residential projects.Key words: Technology House;HVAC Design;Automatic Control SystemTaking Tianjin Haihe Jinmaofu project an an example, this paper mainly introduces the HVAC design scheme [] 发商在一些设计方案中的差异。

通过对冷热源选择,空调/采暖系统设计,通风系统设计及自控设计介绍,使读者对科技住宅项目的暖通设计有一个初步的了解。

[] 科技住宅;暖通设计;自控系统[中图分类号] [文献标志码] B doi :10.3969/J .ISSN. 1005-9180.2020.02.006摘要本文以天津海河金茂府项目为例,主要介绍近些年主流科技住宅中的暖通设计方案,并介绍不同开关键词TU83文章编号:ISSN1005 - 9180 (2020) 02 - 0031 - 06收稿日期:2020-5-7作者简介:周峤(1989-),男,本科,工学学士,工程师,暖通设计师,主要从事暖通设计工作。

某医院暖通设计方案

某医院暖通设计方案

某医院暖通设计方案本文以2013年某医院的暖通设计方案为例,从通风、空调、防排烟系统各方面浅谈方案设计要点。

标签:综合医院;冷热源;水系统;气流组织等1、设计依据1.1《民用建筑供暖通风与空气调节设计规范》(GB50736-2012)1.2《高层民用建筑设计防火规范》(GB50045-952005年版)1.3《汽车库.修车库.停车场设计防火规范》(GB50067-97)1.4 建筑专业所提作业图2、工程概况2.1医院单体建筑包括门急诊楼,医技楼,住院楼,科研教学楼,行政办公楼,学术交流中心等,总建筑面积约40万m2,其中地下建筑面积约10万m2,地上建筑面积约30万m2。

3、设计内容3.1空调系统设计3.2通风及消防防排烟系统设计4、消防防排烟系统设计4.1地下车库分每个防火分区设独立的机械排风(烟)系统,排风系统与排烟系统合用,排烟量按6次/h计算,风机采用双速柜式离心风机,平时开启低档排风,起火时由消防控制中心开启高档排烟;设有通风采光窗的防火分区采用自然补风,无通风采光窗的防火分区设机械补风,保证送风量不低于排烟量的50%。

4.2水泵房、制冷机房、热水锅炉房、蒸汽锅炉房、洗衣房、食堂、走廊等设备用房每个防火分区分别设独立机械送、排风(烟)系统,排风系统与排烟系统合用,排烟量按防烟分区面积的60m3/h计算,排烟风机排烟量按最大防烟分区面积的120m3/h计算,起火时由消防控制中心开启风机排烟,并同时开启送风机,保证送风量不低于排烟量的50%。

4.3每个配电房设独立的机械送、排风系统。

配电房起火时采用气体灭火,排风(烟)管及送风管上设电动防火阀,起火时由消防控制中心自动关闭,灭火后手动开启,排除配电房之有害气体。

4.4柴油发电机房及储油间设机械排风(烟)系统,排风系统兼储油间事故排风,由直接对外开启百叶自然补风。

排风系统与排烟系统合用,排烟量按60m3/h m2计算,起火时由消防控制中心开启风机排烟。

天津四步节能技术标准

天津四步节能技术标准

天津四步节能技术标准(总13页)本页仅作为文档封面,使用时可以删除This document is for reference only-rar21year.March由市建交委建筑节能和科技处组织的天津市居住建筑节能第四阶段节能(四步节能)设计标准的编制工作,经广泛调研和多次组织专家评审论证,本着严格遵照国家标准《严寒和寒冷地区居住建筑节能设计标准》JGJ26-2010的相关规定,在《天津市居住建筑节能设计标准》DB29-1-2010的基础上,再节约30%的能耗作为我市第四阶段的节能目标。

为合理设定节能目标的基准值,仍以1980 -1981年住宅通用设计4个单元6层楼,体形系数为左右的建筑物的耗热量指标为基准值,将居住建筑的采暖能耗降低75%作为节能目标,主要由建筑物和采暖系统共同承担,按此目标对建筑、热工、采暖、给排水和电气设计提出节能措施要求。

现通过对居住建筑节能设计进行数据采集、整理、市场发展调研和太阳能等再生能源应用现状及未来发展趋势分析等,初步拟定我市居建四步节能设计的技术指标。

一、建筑围护结构节能设计1.居住建筑体形系数根据国家标准《严寒和寒冷地区居住建筑节能设计标准》JGJ26-2010,考虑天津地区气候条件,冬、夏季太阳辐射强度、风环境、围护结构构造等各方面因素,权衡利弊,并兼顾不同类型的建筑造型,经过对天津市60栋建筑进行测算,四步节能设计体形系数按国家现行标准执行。

详见表1。

表1 居住建筑体形系数限值建筑层数≤3层的建筑 (4~8)层的建筑 (9~13)层的建筑≥14层的建筑2.居住建筑窗墙面积比限值考虑居住建筑设计的灵活性及功能的合理性,依据国家标准的要求,四步节能设计窗墙面积比限值仍按照《天津市居住建筑节能设计标准》DB29-1-2010执行。

同时规定玻璃及透明部分的太阳辐射透过率不应小于,使冬季室内能够得到更多的太阳能辐射热。

详见表2。

表2 居住建筑的窗墙面积比限值朝向窗墙面积比北东、西南3.围护结构热工性能参数根据对天津市建筑工程实例进行的数据分析,并汲取北京市、黑龙江省、吉林省三地先进的节能设计经验,将四步节能设计中围护结构热工性能参数限值作了调整。

简述天津某高中项目暖通空调设计

简述天津某高中项目暖通空调设计

简述天津某高中项目暖通空调设计摘要:为适应新时代高级中学功能多样性、智能化且绿色环保的特点,本项目在冷热源选择和节能、自控设计方面做了很多工作,主要包括系统能耗分析,冷热源方案对比以及系统运行控制策略等精细化设计。

关键词:复合能源系统能耗模拟新风热回收系统高大空间1 工程概况本项目主要建筑为一所高级中学,地上部分最高五层,使用功能包括教学区、办公区、食堂、学生宿舍等;地下部分一层,使用功能为食堂、风雨操场、小礼堂、汽车库、自行车库及设备用房。

高中设3个年级,24个班(50人/班),总在校学生1200人,教职工100人。

项目总建筑面积37654.07m2,其中地上建筑面积21300 m2,地下建筑面积16354.07 m2;一层层高5.40m,二至五层层高4.20m;地下一层层高3.60m;隔震夹层层高1.80m。

本项目采用地埋管地源热泵和直燃型溴化锂吸收式冷温水机组的复合能源系统。

教室和宿舍等区域空调系统采用风机盘管+新风系统,其中新风系统采用热回收型新风机组;小礼堂和首层大厅采用全空气系统。

本项目除了厨房等局部区域采用散热器供暖系统外,其他区域供暖系统主要为地面辐射供暖系统。

2 室内设计参数3 冷热源方案可行性分析地源热泵是利用地球表面浅层地热资源作为冷热源,进行能量转换的供暖空调系统,系统高效节能、运行费用低、环境效益显著、可同时作为冷热源。

根据《中新天津生态城1B 地块高中地源热泵岩土热物性测试报告》显示:天津市中新天津生态城中部片区,地下含水层厚,地下水位较高,岩土层导热系数大,属于较适宜利用浅层地能的区域,同时该项目为高中学校,具有操场等地下土壤可作为浅层地热能。

本项目冷热源综合考虑现代高级中学的规模和使用特点,中新生态城的能源条件、结构、价格以及国家能耗“双控”和降污减碳环保相关政策,结合全年动态土壤热平衡分析报告和建筑全年能耗动态模拟分析报告,最终确定采用了地埋管地源热泵和直燃型溴化锂吸收式冷温水机组的复合能源系统。

(完整版)天津某住宅小区供热外网课程设计说明书

(完整版)天津某住宅小区供热外网课程设计说明书

目录目录 (I)第一章课程任务书...................................................................................................... - 1 -1.1 已知条件 ............................................................................................................. - 1 -1.2 课程设计内容 ..................................................................................................... - 1 -1.3 具体要求 ............................................................................................................. - 1 - 第二章供热系统的热负荷.......................................................................................... - 1 -2.1供暖设计热负荷的计算 ...................................................................................... - 1 -2.1.1热负荷的计算 ............................................................................................ - 1 -2.1.2流量的计算 ................................................................................................ - 1 -2.2热负荷图 .............................................................................................................. - 1 -2.2.1供暖热负荷随室外温度变化曲线 ............................................................ - 1 -2.2.2热负荷延续时间图 .................................................................................... - 2 - 第三章集中供热系统.................................................................................................. - 5 -3.1 供热系统原理图的确定 ..................................................................................... - 5 -3.2热水供热系统的调节及调节曲线的绘制 .......................................................... - 5 - 第四章管网布置.......................................................................................................... - 7 -4.1热源位置 .............................................................................................................. - 7 -4.2管网的走向 .......................................................................................................... - 7 -4.3管径的选择 .......................................................................................................... - 7 -4.4管道的敷设 .......................................................................................................... - 7 -4.5阀门的设计 .......................................................................................................... - 8 -4.6检查井的设置 ...................................................................................................... - 8 -4.7支架及补偿器的设置 .......................................................................................... - 8 - 第五章水力计算.......................................................................................................... - 9 -5.1水力计算的步骤 ................................................................................................ - 11 -5.2水压图的绘制 .................................................................................................... - 11 -5.2.1水压图的绘制原则 .................................................................................. - 11 -5.2.2绘制水压图的步骤 .................................................................................. - 12 -5.3 水泵的选择 ....................................................................................................... - 12 -5.3.1循环水泵的选择 ...................................................................................... - 12 -5.3.2补给水泵的选择 .................................................................................... - 13 - 参考文献 ................................................................................................ 错误!未定义书签。

天津某研究所污水源热泵工程方案书

天津某研究所污水源热泵工程方案书

世界首创技术水平国际领先天津市园艺工程研究所污水源热泵工程方案书天津市金大地能源工程技术有限公司2011年7月地址:天津市河西区环湖南路9号9门(邮编300060)电话:公司网址:传真:电子信箱:联系人:刘兴泽目录一、污水源热泵方案设计 (2)二、技术参数设计 (3)三、运行参数与工艺流程 (4)四、主要设备选型 (5)五、污水源热泵投资及运行费用估算 (6)六、污水源热泵的优势 (7)七、污水源热泵的应用情况 (8)八、技术及原理概要 (11)九、质量服务体系 (19)一、污水源热泵方案设计(一)项目概况本工程为天津某研究所,建筑面积为4000㎡。

采用风机盘管和散热器作为空调系统的末端装置,拟采用污水源热泵作为空调系统的热源。

用以满足该建筑夏季制冷、冬季采暖的需求。

表1.建筑面积及冷负荷、热负荷备注:设计总制热量为280 kw。

设计总制冷量为260 kw。

根据本项目的冷、热负荷,为节省该项目的初投资,建议使用一套污水源热泵系统,解决建筑的采暖、空调。

(二)项目资源状况本方案利用王顶堤复康路污水干渠中原生污水作为冷、热源,采用热泵技术供热、空调。

(三)总体建设方案为节省该项目供暖、空调系统的一次性投资、便于管理等,建设一个污水源热泵机房,满足建筑供热、空调需求。

按单项建设分为:(1)污水的取水和排水系统工程建设。

(2)水泵、换热器、热泵机组购置及安装,按工程需求量。

(3)热泵机房管线等安装建设。

(4)热泵站低压配电控制系统建设。

(四)此方案优点:(1)降低初投资;节省运行费用;(2)集中控制、集中管理。

(五)方案要点(1)污水输送管道敷设可以采用开挖式,也可以采用非开挖式。

(2)热泵机组的选型按设计冷、热负荷为依据。

(六)空调设计依据GB50019-2003 《采暖通风与空气调节设计规范》GBJ242-82 《采暖与卫生工程施工及验收规范》二、技术参数设计(一)污水数据(常规数据)(1)冬季水温: 10-16℃;(2)夏季水温: 22-24℃;(3)污水水质:PH≈7;(4)设计污水温差冬季3℃、夏季5℃。

天津市西青区人民政府办公室关于印发推进更高水平气象现代化助力西青高质量发展实施方案的通知

天津市西青区人民政府办公室关于印发推进更高水平气象现代化助力西青高质量发展实施方案的通知文章属性•【制定机关】天津市西青区人民政府办公室•【公布日期】2022.05.23•【字号】西青政办发〔2022〕3号•【施行日期】2022.05.23•【效力等级】地方规范性文件•【时效性】现行有效•【主题分类】气象综合规定正文天津市西青区人民政府办公室关于印发推进更高水平气象现代化助力西青高质量发展实施方案的通知各镇人民政府、街道办事处,区政府有关委、办、局,有关区属机构:经区人民政府同意,现将《推进更高水平气象现代化助力西青高质量发展实施方案》印发给你们,请照此执行。

西青区人民政府办公室2022年5月23日推进更高水平气象现代化助力西青高质量发展实施方案为深入贯彻习近平总书记关于气象工作重要指示精神,全面提升气象服务保障能力,着力推进更高水平气象现代化,助力西青区高质量发展,按照《天津市人民政府办公厅关于推进更高水平气象现代化助力天津高质量发展的意见》(津政办发〔2020〕25号)和《天津市气象局关于印发〈天津高质量推进气象现代化建设实施方案(2021—2025年)〉的通知》(津气发〔2021〕52号)等文件要求,结合我区实际,制定本方案。

一、发展目标到2025年,全区基本建成监测精密、预报精准、服务精细的气象现代化体系,气象综合实力位居全市前列。

气象灾害监测率达到99%,强对流天气预警提前60分钟以上,暴雨预警准确率达到92%以上,晴雨预报准确率达到93%。

全面打造更高水平气象现代化新格局。

二、重点建设任务(一)着力提高气象监测精密水平1. 提升地面观测智能化水平。

布设自动雪深观测站、多要素智能气象站。

加强高新技术在观测领域的体系化应用,实现非结构化观测资料、公共基础设施等社会资源的集约和挖掘利用,建设智慧城市自适应观测系统。

充分利用铁塔基站、智能灯杆等社会资源,建立社会化智能气象观测系统。

加强新型观测技术与装备的应用。

青海华源医药现代化物流中心暖通空调系统设计

l工程建设与设计 I Constr ̄cgon&DesignForProject 

青海华源医药现代化物流中心暖通空调系统设计 

Design of HVAC System in Qinghai Huayuan Pharmaceutical Modernized Logistics Center 冯淑琴 (中国中元国际工程有限公司,北京100089) FENG Shu-qin (ChinaIPPRInternationalEngineeringCo.Ltd.,Beijing 100089,China) 【摘要】结合作者多年来从事暖通空调设计的工作经验和相关资料,以青海华源医药现代物流中心项目暖通空调系统为实例,进 行分析设计。为以后从事类4 ̄-Y-作的设计者提供一定的借鉴。 【Abstract]Inthispaper,combinedwiththeworkexperienceandrelatedmaterialsofHVACdesignformanyyears,thispapertakestheHVAC system ofQin ̄ai Huayuan pharmaceutical modem logistics center as an example to analyze and design.and provide some reference for future designerswhoworkinsimilarwork. 【关键词】医药仓库;空调系统;暖通 【Keywords】medicalwarehouse;airconditioningsystem;heatingandventilation 【中图分类号]TU831 【文献标志码IA 【文章编号】1007.9467(2017)04.0050.02 [DOI]10.136160.cnki.gejsysj.2017.04.123 

1引言 由于各种药品的存储方式、存储温度以及存储湿度等都 会导致仓库中药品性质的变化,并且其药品的好坏关乎病人 的生命安全,如果药物}生质发生变化,后果会十分严重。因此, 医药仓储中 必须配置好优良的暖通空调系统,对其温度、湿 度进行调节,使存储的药品全年保持合适的温度、湿度,确保 药品安全。本文对青海华源医药现代物流中心项目暖通空调 系统进行设计。 2暖通空调设计概况 

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

天津西青疾控中心暖通设计
摘要:
一、引言
二、天津西青疾控中心简介
1.地理位置
2.中心规模
3.主要职能
三、暖通设计的重要性
1.确保室内空气质量
2.节能减排
3.营造舒适的办公环境
四、暖通设计方案
1.设计原则
2.空调系统选型
3.通风系统设计
4.供暖系统设计
五、绿色建筑与可持续发展
六、总结
正文:
【引言】
天津西青疾控中心作为我国重要的公共卫生机构,承担着预防和控制疾病
的重要任务。其暖通设计对于保障中心内人员的健康和舒适办公环境具有重要
意义。本文将详细介绍天津西青疾控中心暖通设计的相关内容。
【天津西青疾控中心简介】
天津西青疾控中心位于天津市西青区,紧邻城市主要交通干道,交通便
利。中心占地面积约 20,000 平方米,建筑面积约 50,000 平方米,包括地上
和地下建筑。中心内设有多个业务科室,涵盖了疾病防控、健康教育、科研培
训等多个领域。
【暖通设计的重要性】
暖通设计,即采暖、通风和空气调节设计,是建筑室内环境质量的关键因
素。天津西青疾控中心暖通设计主要考虑以下几个方面:
1.确保室内空气质量:疾控中心内实验室、办公室等场所对空气质量要求
较高,暖通设计需确保新鲜空气的供应和污染物排放。
2.节能减排:合理的暖通设计能够降低能耗,减少温室气体排放,有利于
实现绿色建筑和可持续发展。
3.营造舒适的办公环境:为工作人员提供适宜的温度和湿度条件,提高工
作效率。
【暖通设计方案】
天津西青疾控中心暖通设计方案主要包括以下几个方面:
1.设计原则:遵循舒适性、节能性、环保性和可持续性等原则,结合中心
实际需求进行设计。
2.空调系统选型:选用高能效比的空调设备,实现分区、分时控制,满足
不同场所的空调需求。
3.通风系统设计:采用自然通风与机械通风相结合的方式,确保室内空气
质量。
4.供暖系统设计:采用分布式供暖方式,结合区域能源需求,实现高效节
能。
【绿色建筑与可持续发展】
天津西青疾控中心暖通设计充分考虑绿色建筑和可持续发展的要求,旨在
降低建筑对环境的影响,提高资源利用效率。
【总结】
天津西青疾控中心暖通设计是一个集舒适性、节能性、环保性和可持续性
于一体的综合性设计。

相关文档
最新文档