4.HOW TO USE
Clamp your clamp meter on the pick-up coil of the MULTI-TRAN. Then clamp the MULTITRAN on the conductor as shown bellow. Multiply the reading of your clamp meter by ten.
#WARNING is reserved for conditions and actions that can cause serious or
fatal injury.
#CAUTION is reserved for conditions and actions that can cause minor
Barrier:It is a part providing protection against electrical shock and ensuring the minimum required air and creepage distances.
Conductor Multi-Tran Arrow Mark Clamp Meter
ɹɹRefer to the instructions in the manual.

数字万用表使用说明书

数字万用表使用说明书

数字万用表(DT9205)使用说明书数字万用表(DT9205)使用说明书(适合初学者)一、概述本仪表以大规模集成电路、双积分A/D(模/数)转换器为核心,配以全功能过载保护电路,可用来测量直流和交流电压、电流、电阻、电容、二极管、三极管、温度、频率、电路通断等。

相关术语及仪表盘上的名词解释:LCD/液晶显示屏;交流电的有效值用字母rms表示.例如,市电峰值为311V,有效值为220Vrms;模/数转换器是模拟信号与数字信号相互转换的电子元件;按下仪表盘左上的HD键可以保持LCD数据键;仪表盘下方FUSED表示该量程有保险管,UNFUSED表示无保险管;15SEC是指测试时间限于15秒二、特点1. 功能选择具有32个量程.量程与LCD有一定的对应关系:选择一个量程,如果量程是一位数,则LCD上显示一位整数,小数点后显示三位小数;如果是两位数,则LCD上显示两位整数,小数点后显示两位小数;如果是三位数,则LCD上显示三位整数,小数点后显示一位小数;有几个量程,对应的LCD没有小数显示.2. 测试数据显示在LCD中.3. 过量程时,LCD的第一位显示 "1",其他位没有显示.4. 最大显示值为1999(液晶显示的后三位可从0变到9,第一位从0到1只有两种状态,这样的显示方式叫做三位半。

)5. 全量程过载保护6. 工作温度: 00C-400C储存温度:-100C -- +500C7. 电池不足指示:LCD液晶屏左下方显示三、技术指标精确度:±(%读数+第四位上的字数).注意:括号内的第2部分,为精确度的修正值,应放在该档位的最后一位数字上.精确度保证期为1年例如:一个电子元件在200档位的读数为100.0,该档位精确度标示为±(5%+2),该档位在LCD中有一位小数则这个电子元件的实际数据a,介于不等式100-(5%×100.0+0.2)≤a≤100+(5%×100.0+0.2)即94.8≤a≤105.2环境温度:230C±50C相对湿度: <75%1. 直流电压单位换算:1V=1000mV(毫伏),1mV=1000μV(微伏)分辨率:感知微小电压变化的能力(大概在1/2000),并反映在万用表的最后一位读数上.例如,在量限为200mV的档位,被测直流电源,其电压读数为100mV.当电压升高50μV(微伏)时,万用表读数仍为10 0.0;当电压升高150μV(微伏)时,万用表读数的末位会增加一个字,变为100.1测量电压时,万用表如同一个电阻。

吉时利2000型数字多用表说明书-中文

吉时利2000型数字多用表说明书-中文

吉时利2000型数字多用表说明书打印版本以下所列的打印版本清单列出了所有的版本和附录数据。

版本水平表是按字母顺序增加的,作为随后的更新。

随修订版本而发布的附录,包含重要的信息变更,使用人应该立即将其吸纳在手册中。

附录是有顺序的。

当一个新版本颁布时,所有与之前版本手册相关的附录都会涵盖在新的版本中。

每一个新版本都包括此修订历史页。

版本A(文件编号2000-903-01)——————————1995.04版本B(文件编号2000-903-01)——————————2000.02版本C(文件编号2000-903-01)——————————2007.10安全预警应在使用本设备及相关设备前阅读本安全预警。

虽然设备使用时电压安全,但是仍有不安全的情况存在。

本设备须由有资质的人员操作,能够识别震击危害和类似的安全隐患,以避免可能发生的伤害。

使用前,仔细阅读并遵守所有的安装、操作、维护信息。

参考用户文件。

如果不按说明使用,产品的保护措施预警将会受到破坏。

产品用户类型:负责人:对设备使用与维护负责的个人或团队,确保按说明操作设备以及操作人员接受过培训。

操作人员:使用设备的人员。

必须经过安全流程培训,合适的使用设备。

防止电击和电压电路的危害。

维护人员:常规流程的产品维护,确保其运行稳定,例如,设置线电压或是替换消耗材料。

用户手册对维护流程进行了说明。

如果操作人员进行维护,则需明确的说明流程。

否则,只能由客户人员进行。

客服人员:培训电路工作,安全安装与维修设备。

只有经过合适的培训,客户人员才能完成安装和客服流程的工作。

Keithley设备产品是基于设定的测量范围I和II的电子信号设计的,测量范围见国际电工委员会(IEC)标准IEC60664中的描述。

大多数的测量、控制和数据I/O信号就是测量范围I,并且绝不能直接连接电源电压,或高瞬态过电压的电源电压。

测量范围II的连接要求与本地AC电源接线关联的高瞬态过电压的电源电压的安全。

基尔希2110数字万用表(用户手册)说明书

基尔希2110数字万用表(用户手册)说明书

1.888.KEITHLEY (U.S. only)The Model 2110 5½-Digit Dual-Display Digital Multimeter combines a compelling price with a comprehensive set of capabilities, superior measurement accuracy, and high speed for a broad range of applications. It features 15 measurement functions and 7 math functions and has dual-line display capability, which allows it to display two different measurements concurrently. The Model 2110 is an unbeatable value for production, R&D, and test engineers, scientists, and students making a wide variety of measurements in portable, bench, and system applications.High Accuracy, Abundant Capabilities, Low CostThe Model 2110 provides precision and a rich set of capabilities at a value price. It has 0.012% one-year basic DC voltage accuracy and 0.020% one-year basic resistance accuracy up to the 100k W range.The Model 2110 provides a wide number of measurement ranges and functions:• DC voltage: 0.1V, 1V, 10V, 100V, and 1000V • AC voltage: 0.1V, 1V, 10V, 100V, and 750V • DC current: 10mA, 100mA, 1A, 3A, and 10A • AC current: 1A, 3A, and 10A• Two- and four-wire resistance: 100W , 1k W , 10k W , 100k W , 1M W , 10M W , and 100M W • Frequency: From 10Hz to 300kHz• Capacitance measurement: 1nF, 10nF, 100nF, 1µF, 10µF, 100µF• Thermocouple measurement: J-, R-, S-, T-, E-, N-, B-, C-, and K-type thermocouples • Temperature (RTD and NTC Thermistor) measurements• Diode measurement • Continuity test• Programmable A-D converter and filter settings for signal to noise optimization. Additionally, seven mathematical operations can be performed on measurement readings: percentage, average, min/max, NULL, limits, mX+b, dB, and dBm testing.SpeedAt 5½ digits, the Model 2110 delivers up to 200 readings/s via the USB remote interface. At the fast 4½-digit setting, it reads up to 50,000 readings/s and up to 30,000 readings/s into the buffer, making it ideal for production and monitoring applications in which speed is c ritical.5D I G I T A L M U L T I ME T E R S & S Y S T E M S1.888.KEITHLEY (U.S. only)SimplicityThe Model 2110 is operational and intuitive to use right out of the box. The functions on the front panel are user friendly and easy to read. Its KI-Tool and KI-Link software allow users to quickly con-trol the instrument over GPIB (if equipped) or USB, record measurements, and display time-series L o w -c o s t 5½-d i g i t D M M f o r s y s t e m , b e n c h , o r p o r t a b l e a p p l i c a t i o n s All accessories, such as start-up software, USB cable, power cable, and safety test leads, are included with the Model 2110.KI-Tool simplifies basic measurement applications through every setup and graphical data representation.1.888.KEITHLEY (U.S. only)SpecificationsDC CHARACTERISTICSDC VOLTAGEAccuracy 1±(% of reading + % of range)1 Year, 23° ±5°C Temperature Coefficient 0°–18°C & 28°–40°C Range Resolution InputResistance 100.000 mV 1 µV 10 M W 0.012 + 0.0040.001 + 0.00051.00000 V 10 µV 0.012 + 0.0010.0009 + 0.000510.0000 V 0.1 mV 0.012 + 0.0020.0012 + 0.0005100.000 V 1 mV 0.012 + 0.0020.0012 + 0.00051000.00 V10 mV 0.02 + 0.0030.002 + 0.0015DCI (DC CURRENT)Accuracy 1±(% of reading + % of range)1 Year, 23° ±5°C Temperature Coefficient 0°–18°C & 28°–40°CRange Resolution ShuntResistance 10.0000 mA 0.1 µA 5.1 W 0.05 + 0.0200.005 + 0.002100.000 mA 1 µA 5.1 W 0.05 + 0.0100.005 + 0.0011.00000 A 10 µA 0.1 W 0.150 + 0.0200.008 + 0.0013.0000 A 100 µA 0.1 W 0.200 + 0.0300.008 + 0.00110.0000 A 100 µA 5 m W 0.250 + 0.0500.008 + 0.001RESISTANCE 2Accuracy 1±(% of reading + % of range)1 Year, 23° ±5°C Temperature Coefficient 0°–18°C & 28°–40°CRange Resolution Test Current 100.000 W 1 m W 1 mA 0.020 + 0.0200.003 + 0.0005 1.00000 k W 10 m W 1 mA 0.020 + 0.0030.003 + 0.0005 10.0000 k W 100 m W 100 µA 0.020 + 0.0020.003 + 0.0005 100.000 k W 1 W 10 µA 0.020 + 0.0020.003 + 0.00051.00000 M W 10 W 1 µA 0.030 + 0.0040.005 + 0.000510.0000 M W 100 W 0.1 µA 0.200 + 0.0040.05 + 0.0005100.000 M W 1 k W0.1 µA2.000 + 0.0050.5 + 0.0005DIODE TESTAccuracy 1±(% of reading + % of range)1 Year, 23° ±5°C Temperature Coefficient 0°–18°C & 28°–40°CRange Resolution Test Current 1.0000V 10 µV1 mA0.020 + 0.0300.002 + 0.0005CONTINUITYAccuracy 1±(% of reading + % of range)1 Year, 23° ±5°C Temperature Coefficient 0°–18°C & 28°–40°CRange Resolution Test Current 1000W 10 m W1 mA0.020 + 0.0200.002 + 0.00051. Specifications valid after two hour warm-up.a. ADC set for continuous trigger operation.b. Input bias current <30pA at 25°C.c. Measurement rate set to 10 PLC.2. Specifications for 4W ohms mode. For 2W ohms, use zero null or subtract lead resistance from displayed reading.a. Maximum lead resistance 10% of range per lead for 100W and 1k W ranges; add 1k W per lead for all other ranges.MEASUREMENT NOISE REjECTION DC (60Hz/50Hz) at 5.5 DIGITS CMRR: 120dB for 1k W unbalance in LO lead.NMRR: 60dB for line frequency ±0.1%.TEMPERATURE (THERMOCOUPLE) CHARACTERISTICSThermocoupleType Range Accuracy 1 ±°C1 Year, exclusive of lead accuracyB 600 to 1800°C 1.5C 0 to 2300°C 1.5E –250 to 1000°C 1.5J –200 to 1200°C 1.0K –200 to 1350°C 1.0N –200 to 1300°C 1.0R 0 to 1750°C 1.5S 0 to 1750°C 1.5T–250 to 400°C1.51. Specifications valid after two hour warm-up; a. ADC set for continuous trigger operation.RTD and NTC Thermistor Measurements: Accuracy ±0.8˚C, 1 year, exclusive of leadaccuracy. PT100, D100, F100, PT385, PT3916, SPRTD (R-Zero, A4, B4, Ax, Bx, Cx, and Dx), NTCT (A, B, and C), and user-definable RTD.CAPACITANCE CHARACTERISTICSRange Test Current Accuracy 1±(% of reading + % of range)1 Year, 23° ±5°C1.000 nF 10 µA2.0 + 0.801. Specifications valid after two hour warm-up.a. ADC set for continuous trigger operation.b. Null enabled.2110Model 2110 rear panel.。

万用表的正确使用方法

万用表的正确使用方法

万用表的正确使用方法万用表是电力维修人员必备的故障查找工具,电力师傅们都知道,在日常的维修保养过程中,万用表发挥着极其重要的作用,那么如何使用万用表呢?下面是小编给大家带来的万用表的正确使用方法_万能表用法功能介绍,以供大家参考!万用表基本介绍简介:万用表是为节省时间、减少麻烦设计的仪器,仪器带有各种省事时功能、如自动测量、内置分析和前面板快捷按钮,如吉时利高性能用表7、8位半解决方案及灵活性的多功能DMM.▼万用表测量对象电压、电流、电阻、二三级管、半导体器件。

▼万用表的使用方法1.测量先看挡,不看不测量使用万用表进行测量时,务必再核对一次电参量的类型及量程,选择开关是否拨对位置2.测量不拨挡,测完拨空挡测量过程中不能任意拨动旋钮,特别是测高压(如220V)或大电流(如0.5A)时,以免产生电弧,烧坏转换开关触点。

测量完毕后,将量程选择开关拨会Off档。

3.表盘应水平,读数要对正使用万用表时应该水平旋转,读取示数时视线应正对着万用表指针(数字式不需这样)。

4.量程要合适,针偏过大半选择量程,若事先无法估计被测量大小,应尽量选较大的量程,然后根据偏转角大小,逐步换到较小的量程,直到指针偏转到满刻度的2/3左右为止。

数字式万用表即不断调小档位,直至调至合适档位。

5.测R不带电,测C先放电严禁在被测电路带电的情况下测电阻。

检查电器设备上的大容量电容器时,应先将电容器短路放电后再测量。

6.测R先调零,换挡需调零测量电阻时,应先将转换开关旋到电阻挡,把两表笔短接,旋调零电位器,使指针指零欧后再测量。

每次更换电阻挡时,都应重新调整欧姆零点。

7.黑负要记清,表内黑接“+”红表笔为正极,黑表笔为负极,但电阻挡上黑表笔接内部电池的正极。

8.测I应串联,测U要并联测量电流时,应将万用表串接在被测电路中;测量电压时,应将万用表并联在被测电路的两端。

9.极性不接反,单手成习惯测量电流和电压时应特别注意红、黑表笔的极性不能接反,并且一定要养成单手操作的习惯以确保安全。

74 Series 2400 SourceMeter SMU Instruments 产品介绍说明书

74 Series 2400 SourceMeter SMU Instruments 产品介绍说明书
74
Series 2400 SourceMeter® SMU Instruments
MODEL 2400 / 2401 2410 2440 2420 / 2425
STOCK CODE
CURRENT MAX / MIN 1.05A /10pA 1.05A /10pA 5.25A /100pA 3.15A /100pA
C/2420-3Y-17025
(ISO-17025 accredited) calibrations within 3 years of purchase for Models 2420*
C/2425-3Y-17025
(ISO-17025 accredited) calibrations within 3 years of purchase for Models 2425*
VOLTAGE MAX / MIN 200V/1μV (20V 2401) 1100V/1μV 40V/1μV Up to 100V/1μV
POWER 20W 20W 50W 60W/100W
Series 2400 SourceMeter® SMU Instruments
RECOMMENDED ACCESSORIES
KUSB-488B
IEEE-488 USB-to-GPIB Interface Adapter
8501-1
Trigger Link Cable, DIN-to-DIN, 1m (3.3 ft)
8501-2
Trigger Link Cable, DIN-to-DIN, 2m (6.6 ft)

3 Series 2400 family offers 7 unique models covering the industry’s widest range of voltage, current and power levels for a best fit for your unique I-V characterization applications and devices.

keithley(吉时利)2450,2460中文手册

在触摸屏上选择项目 .................................................................................................................. 2-5 滚动条 ....................................................................................................................................... 2-6 交互式滑动屏............................................................................................................................. 2-6 菜单概述.................................................................................................................................... 2-9 将测量值存储到 U 盘 ........................................................................................................ 2-10 将屏幕截图存储到 U 盘..................................................................................................... 2-10

数字万用表说明书

TMFeatures• 2000 Counts Display • Manual Function Select• Diode, Transistor Test & Continuity Buzzer •Auto Power Off• Low Battery Indication • Data Hold• Full Icon Display• Input Impedance for DC Voltage: 10MΩ• Test Lead Connection Indications TMImportant Notice : This data sheet and its contents (the “Information”) belong to the members of the Premier Farnell group of companies (the “Group”) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence. Tenma is the registered trademark of the Group. © Premier Farnell Limited 2016.Part Number TableDescription Part Number Digital Multimeter72-13500Electrical SpecificationsParameter RangeDC Voltage (V)200mV / 20V / 200V / 1000V ±(0.5% + 1 digit)AC Voltage (V)2V / 200V / 1000V ±(0.8% + 3 digits)DC Current (A)2mA / 200mA / 20A ±(0.8% + 1 digit)AC Current (A)2mA / 200mA / 20A ±(1% + 3digits)Resistance (Ω)200Ω / 2kΩ / 200kΩ / 2MΩ / 20MΩ ±(0.8% + 1 digit)Capacitance (F)20nF / 200nF / 2μF / 100μF ±(2.5% + 5 digits)Inductance (H)2mH / 20mH / 200mH / 20H ±(2% + 10 digits)General CharacteristicsSafety Rating : CAT II 1000V, CAT III 600V Power : 9V Battery (6F22)LCD Size : 60mm x 54mm Colour : Orange and GreyWeight: 350g (Including Holster)Dimensions: 179mm × 88mm × 39mmAccessoriesBattery, Test Lead, Holster, Multi-Purpose Socket and Instruction Manual。

虹润NHR-2400系列频率转速表使用说明书

版本号:2400-120410NHR-2400系列频率/转速表使用说明书一、产品介绍NHR-2400系列频率/转速表采用全自动贴片封装工艺,具有很强的抗干扰能力。

六位LED数码显示,显示范围宽。

带多种输出功能:上下限报警控制输出、4-20mA模拟量输出、RS485/RS232通讯等,多种输入方式,适用于各种测速场合。

三、仪表面板1)面板指示:PV:显示测量值;在参数设定状态下,显示参数符号和参数值A/T:显示速率,指示灯亮。

B/D:备用。

AL1:第一报警指示灯。

AL2:第二报警指示灯。

Hz:频率转速表指示灯亮。

C:备用。

T:备用。

注:外形尺寸为96*48mm时,无Hz、C、T指示灯。

1)菜单设置2)参数设置(以更改报警类型为例)3)参数说明A 、转速设置参数说明:B、报警设置参数说明:C、通讯设置参数说明:D 、变送输出设置参数说明:E 、功能设置参数说明:注:不同外型仪表后盖接线端子的方向不一样,见示意图注2:仪有内部主板上有一个六位拔码开关,123设置输入类型,456无效(备用),如下图所示: 拨码1:ON 为磁性开关输入;OFF 为逻辑输入; 逻辑:输入触发电平IIL=1.5Vmax ;VIH=3.75Vmin 。

磁性开关:峰值输入200mV (PNP 必须放在on 位置)。

拨码2:ON 为PNP 输入;OFF 为NPN 输入;PNP:增加一个内部电阻3.9KΩ下拉电阻,7.3mA max@28VDC,NPN:增加一个内部7.8KΩ上拉电阻至+12VDC,I max=1.9mA。

拨码3:ON为低频输入;OFF为高频输入;高频:去掉阻尼电容,允许最大频率。

低频:增加一个阻尼电容,用于开关触点回跳。

而且限制输入频率50Hz和脉冲宽度10毫秒。

六、仪表选型NHR-2400□-□/□/□/□()-□备注:在写型号时必须完整,没有选到的功能项不能省略,必须用“X”补上。

型号举例:NHR-2400A-0/2/D1/P(24)-A。

万用表 说明书

5.蜂鸣器 在任一测量档位(2/20A 电流测量档除外)按动任
6
UT201、202 使用说明书
意功能按键,如果该键有效,蜂鸣器会发“哔” 的一声,无效则不发声;自动关机前约 1 分钟蜂 鸣器会连续发出 5 声警示;关机前蜂鸣器会以 1 长声警示。 注意:在 2/20A 电流测量档,钳表已设定蜂鸣器 不会发声。
3.SELECT:为功能选择键,以触发方式工作, 用此键可作为Ω/ / ,℃/℉的切换。
4.自动关机 在测量过程中,功能按键和转盘开关在 15 分钟内 均无动作时,钳表会“自动关机”(休眠状态), 以节约电能;要取消自动关机功能,只要按着 HOLD 键开机,则自动关机功能被取消。在自动 关机状态下,按动功能键(有效的按键操作,详 见 6.)或是转动转盘开关,钳表会“自动开机”(工 作状态)。 注意:⑴在温度测量档(UT202)自动关机后, 转换到交流电流档则不能唤醒,转换到其它档能 够唤醒;⑵在休眠状态下按 HOLD 键唤醒,自动 关机功能被取消。
2
UT201、202 使用说明书
断,并将所有电容器放电。测量完毕,要断开 表笔与被测电路的连接,并从钳表输入端拿掉 表笔以及关断钳表电源。 8.当液晶显示器显示“ ”标志时,应及时更换电 池,以确保测量精度。钳表长期不用时,应取 出电池。 9.请勿随意改变钳表内部接线,以免损坏仪表和危 及安全。 10.不要在高温、高湿、易燃、易爆和强电磁场环 境中存放、使用钳表。 11.维护保养请使用软布及中性清洁剂清洁仪表外 壳,切勿使用研磨剂及溶剂,以防外壳被腐蚀, 损坏仪表、危及安全。
9
UT201、202 使用说明书
3.电阻测量(Ω)(见图 5) 警告:在连接负载以前务必将电路电源切断
*设置转盘 *选择功能 电阻测量为最初设定值 *连接负载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Keithley 2400 Source Meter•电压源、电流源、电压表、电流表四合一新型仪器,适用于快速直流测试•可选高电压型 (1100V)、大电流型 (3A)或大电流脉冲型(10A)电源/测量•最大功率:20W (2400和2410),60W (2420),100W (2425/2430 直流模式),1kW (2430 脉冲模式)•五位半数字电表, 0.012%准确度•可作六线式奥姆测量•程控电流/电压,并可设定箝制准位•最快速度可达1000点/秒(GPIB接口)•内建快速「通过/失效」比较器,适用于自动化质量管理•数字I/O可直接与其它仪器沟通•IEEE-488和RS-232界面•除量测电压、电流外,并可直接量测电阻、功率、百分率、补偿电阻(Offset Compensated Ω)、变阻器α值(Varistor α)、电压系数,如需做接触检测(Contact Check),可选用 2400C 系列1美商吉時利儀器股份有限公司台灣分公司美商吉時利儀器股份有限公司台灣分公司2Keithley 2400系列(2400,2410,2420,2430) 多功能电源电表简易操作手册一、功能:二、面板简介:图2—1 2400屏幕显示图屏幕显示:如图2—1所示,屏幕左上方所显示为「量测值」,右上方为「输出开/关」显示,左下方为「电源输出值」,右下方为「箝位值」显示。

• 电压源、电流源、电压表、电流表四合一新型仪器,适用于快速直流测试• 可选高电压型 (1100V)、大电流型 (3A ) 或大电流脉冲型 (10A ) 电源/测量• 最大功率:20W (2400和2410),60W (2420),100W (2430 直流模式),1kW (2430 脉冲模式)• 五位半电表, 0.012%准确度 • 可作六线式奥姆测量• 程控电流/电压,并可设定箝制准位 • 最快速度可达1000点/秒(GPIB 接口)• 内建快速「通过/失效」比较器,适用于自动化质量管理 • 数字I/O 可直接与其它仪器沟通 • IEEE —488和RS-232界面• 除量测电压、电流外,并可直接量测电阻、功率、百分率、补偿电阻(Offset123.456 uA ( 量測值 ) ON (輸出開/關)Vsrc: +00.0000V ( 電源輸出值 ) Cmpl:105.000uA (箝位图2-2 2400正面图图2-3 2400背面图Power:电源开关MEAS选择键:选择所欲量测的讯号(1)V量测电压(2)I量测电流(3)Ω量测电阻(4) FCTN量测功率 , 补偿电阻,电压系数 , 变电阻ALPHA值 ,百分率 (初始设定为功率)SOURCE选择键:选择电源输出型式(1) V输出电压(2) I输出电流(3)▲和▼增加或减少输出值或箝位值(Cmpl)操作键:3美商吉時利儀器股份有限公司台灣分公司(1)EDIT选择设定电源输出值或箝位值(2)TOGGLE切换输出值与量测值位置(3) LOCAL取消远程计算机控制,回到仪器面板控制(4) REL开启/取消参考数值比较(5) FILTER开启/取消数字滤波(6)LIMIT开启/取消限制值测试(7)TRIG从面板触发开始量测(8) SWEEP开始输出设定好的扫瞄电压或电流(9) DIGITS改变量测显示数字(10) SPEED改变量测速度及精准度(11)STORE设定记忆数量并开始储存(12)RECALL显示储存的量测数值(13)CONFIG设定 (加上其它按键,如CONFIG + SWEEP 可设定扫瞄输出)(14) MENU进入可储存设定值,更改通讯方式(IEEE-488 or RS232),或校正(15)EXIT跳出(16) ENTER确认RANGE:范围选择(1)▲更改为较大的范围(2)▼更改为较小的范围(3)AUTO自动切换至最佳范围OUTPUT:(1) ON/OFF开启/取消电源输出三、操作入门A.输出电压,量测电流1.接线如图3-1。

2。

按SOURCE V ,设定输出电压(由”EDIT” 左、右键来更改光标位置,并经由”SOURCE”4美商吉時利儀器股份有限公司台灣分公司▲ , ▼及各数字键来设定数值)。

3.按MEAS I(量测电流)。

4.按OUTPUT ON/OFF 输出。

(灯亮代表输出)※若单纯量测电流,可将电压设为0V做电流表用。

5。

自面板读取量测值。

图3—1 二线式接线图B。

输出电流,量测电压1. 接线如图3-1。

2.按SOURCE I ,设定输出电流(由"EDIT” 左、右键来更改光标位置,并经由 "SOURCE" ▲,▼及各数字键来设定数值)3.按MEAS V(量测电压)。

4.按OUTPUT ON/OFF 输出。

(灯亮代表输出)※若单纯量测电压,可将电流设为0A做电压表用.5。

自面板读取量测值.C。

量测电阻1.做两线式量测接线如图3—1;若做四线式量测接线如图3—2。

2。

先按「CONFIG 」再按「」,做电阻量测设定,进入「SENSE—MODE」,选择两线式量测或四线式量测。

3。

按SOURCE I。

5美商吉時利儀器股份有限公司台灣分公司美商吉時利儀器股份有限公司台灣分公司64。

按MEAS Ω.5。

按OUTPUT ON/OFF 输出电源。

6。

自面板读取量测值。

图3—2 四线式接线图D.量测功率1。

接线如图3—1.2.先按「CONFIG 」,然后按「FCTN 」,选择「POWER 」然后按「ENTER 」。

3.按SOURCE I 或 V 。

4.按MEAS 「FCTN 」。

5。

按OUTPUT ON/OFF 输出电源. 6。

自面板读取量测值。

E 。

补偿电阻(Offset Compensated Ω)1212I I V V--=Ω補償電阻1。

接线如图3—1。

2.先按「CONFIG 」,然后按「FCTN 」,选择「OFF-COMP-OHMS 」然后按「ENTER 」。

3.设定I1,I2。

美商吉時利儀器股份有限公司台灣分公司74.按SOURCE I 。

5按「FCTN 」。

6。

按OUTPUT ON/OFF 输出电源。

7。

自面板读取量测值。

F 。

量测变阻器α值(Varistor α))log()log(1212V V I I=α1.接线如图3—1。

2.先按「CONFIG 」,然后按「FCTN 」,选择「VAR-ALPHA 」然后按「ENTER 」。

3。

设定I 1,I 2。

4.按SOURCE I 。

5.按「FCTN 」.6.按OUTPUT ON/OFF 输出电源。

7。

自面板读取量测值。

G 。

量测电压系数%100)(%12212⨯-⨯-=V V R R R 電壓係數1. 接线如图3-1.2。

先按「CONFIG 」,然后按「FCTN 」,选择「VOLT-COEFF 」然后按「ENTER 」。

3.设定V 1,V 2. 4。

按SOURCE V 。

5.按MEAS 「FCTN 」。

6。

按OUTPUT ON/OFF 输出电源。

7。

自面板读取量测值。

H.量测百分比美商吉時利儀器股份有限公司台灣分公司8100%⨯-=參考值參考值儀器讀值1。

接线如图3—1.2。

先按「CONFIG 」,然后按「FCTN 」,选择「%DEV 」然后按「ENTER 」. 3.设定参考值「REF 」。

4.设定参考高低容许范围「HI TOL 」、「LO TOL 」。

5.按SOURCE I 或 V 。

6。

按MEAS 「FCTN 」。

7。

按OUTPUT ON/OFF 输出电源。

8。

自面板读取量测值。

四、电源扫描(sweep )设定2400共有四种扫描模式:线性阶梯波扫描(linear staircase )、对数阶梯波扫描(logarithmic staircase )、自订波型扫描(custom )、内存扫描(source memory )。

这四种模式简述如下:线性阶梯波扫描(linear staircase )如图4-1所示,必须设定起始准位(START )、结束准位(STOP)、位阶大小(STEP )、延迟时间(DELAY )。

图4—1 线性阶梯波对数阶梯波扫描(logarithmic staircase )如图4-2所示,必须设定起始准位(START )、结束准位(STOP)、扫描点数(NO OF POINTS )、延迟时间(DELAY)。

图4—2 对数阶梯波自订波型扫描(custom)如图4—3所示,必须设定扫描点数(#-POINTS)、各点的准位(ADJUST-POINTS)、延迟时间(DELAY)。

图4-3 对数阶梯波内存扫描(source memory)我们可以把不同的量测组态存在内存中,然后透过记忆扫描来做不同组态的测试,最多可以设定100组不同的量测组态.举例而言,对一待测组件,我想先送电压量电流,然后再送电流量电压,最后测它的电阻值,那么我可以先把送电流量电压的设定存入内存中,再存入送电流量电压的设定,最后存入电阻量测的设定,完成以上设定之后做记忆扫描即可循序完成以上三种测试。

操作:A.线性阶梯波扫描(linear staircase)9美商吉時利儀器股份有限公司台灣分公司1.选择送电压(按「V」)或送电流(按「I」)。

2.按「CONFIG」然后按「SWEEP」,进入「TYPE」选项,选择「STAIR」.3.进入起始准位(START)设定,按EDIT左、右键来改变光标位置,可直接按各键来设定数值(如按「LOCAL」即”0”,「REL」即”1" …),或按▲和▼来循序改变数值,确定之后按「ENTER」。

4.同步骤三,依序设定结束准位(STOP)、位阶大小(STEP)后,回到扫描设定选单(CINFIGURE SWEEPS)。

5.选择「SWEEP COUNT」,选择扫描循环数,「FINITE」可设定有限循环数,「INFINITE」则可无限制进行扫描。

6.回到扫描设定选单(CINFIGURE SWEEPS),进入「SOURCE—RANGING」,设定电源范围模式设定,「BEST—FIXED」、「AUTO—RANGE」或「FIXED」.※以上三种电源范围模式详细说明可参考「User’s Manual 」10-10页.7。

做完以上设定之后,按「EXIT」键回到主画面,按「CONFIG」键后按「TRIG」键,进入「TRIG-LAYER」,再进入「DELAY」选项,设定延迟时间(DELAY).8.回到主画面,按「ON/OFF」输出电源,然后按「SWEEP」则自动进行扫描量测。

9. 扫描完毕之后,再按一次「ON/OFF」关闭电源,按「RECALL」键可显示内存中储存的各量测值,如图4—4.可按▲和▼改变内存位置,选择不同扫描准位下的量测值,右下角并显示时间(以开始量测的时间为基准时间)。

相关文档