结构原理设计计算书2计算书2

目录

1.正截面计算.................................................... 1 1.1设计容........................................................1 1.

2.截面尺寸........................................................1 1.

3.材料规格........................................................1 1.4荷载取值计算....................................................1 1.5.跨中截面纵向受拉钢筋计算........................................2 1.6正.截面复核..................................................... 4

2.斜截面设计.....................................................6 2.1.腹筋设计........................................................ 6

2.2.箍筋设计........................................................7 2.

3.弯起钢筋及斜筋设计..............................................7 2.

4.抗弯承载力计算..................................................10

2.5.弯起钢筋弯起点位置检查..........................................13

2.6斜截面抗剪承载力的复核.........................................16 结束语............................................................24

参考文献.................................................................25 附录.........................................................................

1.正截面计算

1.1.设计容:装配式钢筋混凝土简支梁。桥梁处于Ⅰ类环境条件,安全等级为二级0γ=1,梁承受均布荷载q=40kN/m.

1.2.截面尺寸.

钢筋混泥土的简支梁计算跨径L=18m 。T 形截面梁的尺寸如图 1.1,梁肋宽度b=200mm,翼板宽度为1750mm,翼板边缘厚度为100mm,翼板中间处厚度为150mm

1.3.材料规格

梁体采用C30混凝土,轴心抗压强度的设计值为cd f =13.8MPa ,轴心抗拉强度设计值td f =1.39MPa 。主筋采用HRB335的钢筋。抗拉强度设计值为f '

sd =sd f =280MPa 。箍筋采用R235级钢筋。直径8mm,其抗拉强度设计值为sd f =195Pa,抗压强度设计值f 'sd =195Pa.

1.4荷载取值计算

跨中截面 2/,l d M =82

ql =1620kN ⋅m 2/,l d V =70kN 1/4跨截面 2/,l d M =1215kN ⋅m

支点截面 0,d M =0 0,d V =2

ql =360kN 1.5.跨中截面纵向受拉钢筋计算

(1)T 形截面的受压翼板的有效宽度f b '

○1简支梁跨径的L/3处

由图1-1所示的T 形梁截面受压翼板厚度的尺寸,可得翼板平均厚度f h '=1252

150100=+mm, 1f b '=1/3L=6000mm ○2='2'f b b+2h b +12f h =1700mm

③设相邻两主梁间的平均间距1800'

3'=f b mm,取三者中的最小值,故取受压翼板

的有效宽度为f b '=1700mm 。

(2)钢筋数量的计算

已知预制钢筋混凝土简支T 形梁h=1.35m,翼板f b '=1.7m ,C30混凝土,HRB335钢筋。I 类环境条件,安全等级为二级。跨中2/,l d M =1620kN ⋅m

求:配筋(焊接钢筋骨架)计算及截面复核

解:

○1计算参数cd f =13.8MPa td f =1.39MPa sd f =280MPa b ξ=0.56 0γ=1.0 M=0γ2/,l d M =1620kN ⋅m

2截面换算,为了计算方便,将图1-1的实际T 形截面换算成图1-2所示的计算截面:f h '=2

100150+=125mm

3截面设计 (1)因采用的是焊接钢筋骨架,故设s a =30+0.07h=124.5mm ,截面有效高度为0h =1225.5mm

(2)判断T 形截面类型

)2'

(''0f f cd h h h bf f -=3410.5kN ⋅m>M=1620kN ⋅m 故属于第一类T 形截面

(3)求受压区高度

由u M =)2

('0x h x b f f cd - 整理得 042.138********=+-x x

解得:'7.57''1f h mm x <=或mm x 3.23932=(舍)

(4)求受拉钢筋的面积As ,选配钢筋。

As=sd f cd f x

b f '=4834.4mm 2

选4Φ28+2Φ25+22,总面积As =5726mm 2 ,钢筋叠高为6层,混凝土保护层厚度取35mm>d=28mm,及规定的30mm.钢筋间的横净距n S =200—2×35-2⨯31.6=66.8mm >40mm 及1.25d=1.25×28=35mm 故满足构造要求。

钢筋验算钢筋布置图1-3

1.6正.截面复核

已知设计的受拉钢筋中,4Φ28的面积为2463mm 2,2Φ25的面积为982mm 2 ,

6Φ22的面积为2281mm 2,sd f =280MPa

s a =2281

9822463)

4.28

5.02.6335(982)1.255.14.28

6.31235(2281)6.3135(2463++⨯+++⨯++⨯+++=113.4mm

实际的有效高度 0h =1350-113.4=1236.6mm

(1)判定T 形截面类型

''f f cd h b f =2993kN

s sd A f =1600kN 由于

''f f cd h b f >s sd A f ,故为第一类T 形截面

(2)求受压去高度x

x ='

f cd s sd b f A f =68.3mm

u M =)2

('0x h x b f f cd -=1929.3kN ⋅m >M=1620kN ⋅m (4)验算少筋

ρ=0

bh A s ×100%=2.3% 故截面复核满足要求。

2.斜截面设计

2.1腹筋设计

(1)截面尺寸检查(上限值验算)

《公路桥规》规定:

在钢筋混凝土梁的支点处应该至少有两根且不小于0.2A s 的钢筋穿过支座中

心,2Φ28钢筋穿过支座中心即可,此时支点截面有效高度为0h =h-(35+26.31)=1299.2mm

上限值()0,31051.0bh f k cu -⨯=725.8kN> 0γ0,d V =360kN

则截面尺寸符合要求。

(2)检查是否需要根据计算配箍筋

跨中截面(0.5×10-3)0bh f td 2α=171.9kN

支座处截面(0.5×10-3)0bh f td 2α=180.6kN

由于0γ2/,l d V =70kN <(0.5×10-3)0bh f td 2α< 0γ0,d V =360kN,因此,在梁的跨中某长度围按构造要求选配钢筋,其余段应按计算配置复筋。

(3) 计算剪力分配图(图1-4见附录)

在图1-4所示的剪力包络图中,支点处剪力计算值V=0γ0,d V =360kN ,跨中处剪力计算值2/,l d V =0γ2/,l d V =70kN

x V =0γx d V ,=171.9kN,根据1-4图中的比例关系可得

2

/02/012l l x V V V V l l --==23162.4mm 即在1l 的长度可按构造要求布置箍筋。 距支座中心线为2/h 处的计算剪力值(V'),由三角形比例计算

()L

V V h LV V l 2/00'--==338.25kN 由混凝土和箍筋承担的剪力计算值至少为0.6V'=202.95kN ,由弯起钢筋(包括箍筋)承担的剪力值计算值最多为0.4V'=135.3kN.设置弯起钢筋区段的长度为⎪⎭

⎫ ⎝⎛--=

22''4.002/h l V V V l l w =4199mm 围,箍筋的间距最大为100mm.

2.2箍筋设计

箍筋的构造要求:

取直径为8mm 的双肢箍筋,箍筋截面A SV =nA SV1=100.6mm 2

在等截面钢筋混凝土简支梁中,箍筋尽量做到等距离布置,为了简便计算,斜截面纵向配筋率p 及截面有效高度0h 可近似按支座截面的跨中截面的平均值取用,计算如下:

跨中截面: 1000

2/⨯=bh A p s l =2.3>2.5取2/l p =2.3,0h =1236.6mm 支点截面: 0p =0

bh A s ⨯100=0.47 ,取0h =1299.2mm 则平均值分别为p =

202/p p l +=1.24,0h =1299.2mm 箍筋间距V S =()

()220,62321')6.02(1056.0V bh f A f p sv SV k cu +⨯-αα=561.3mm

经验算可取V S =250mm SV ρ=v

SV bS A =0.2%>0.18% 满足要求。 综上,在支座中心跨径长度方向的1400mm ,设计箍筋间距为

V S =100mm,其它至跨中截面统一采用箍筋间距V S =250mm..(箍筋布置图见附录图2-0)。

2.3弯起钢筋及斜筋设计

设置为焊接钢筋骨架的架立钢筋为HRB335Φ22,钢筋重心至受压翼板上边缘距离为's a =56mm,弯起钢筋的弯起角度为450。首先,计算弯起钢筋上下弯点之间的垂直距离i h ∆,弯起钢筋细节图2-1.

1根据《公路桥规》规定,简支梁的第一排弯起钢筋的末端弯折点应位于支座中心处。

1h ∆=1350—[(35+31.6×1.5)+(43+25.1+31.6×0.5)]=1183.7mm

弯筋的弯起角为450,则第一排弯筋(2N5)的弯起点1距制作中心距离为1183.7mm, 钢筋与梁轴交点1'到支座中心距离为

1183.7-[2

1350-(35+31.6×1.5)]=591.1mm ; 分配的剪力值为1Sb V =0.4V'=135.3kN

需要的弯起钢筋为A sb1=s

sd f sb θsin 1V 33.1333=911.3mm 2 可供的弯起钢筋为A sb1=1232mm 2(2Φ28)

2对于第二排弯起钢筋 2h ∆=1350—[(35+31.6×2+28.45.0⨯)+(43+25.1+28.4×0.5)]=1155.3mm 弯起钢筋(2N4)的弯起点2距支点中心距离为1183.7+1155.3=2339mm

分配的剪力值为4199

h 4199V V 1

2h sb12sb ∆-+= V Sb2=118.9kN 需要的弯起钢筋为A sb2=

45sin f 33

.1333sd V Sb2=800.8mm 2

可供的弯起钢筋为A sb2=982mm 2(2Φ25) 钢筋与梁轴交点到支座中心2'距离为

2339-)]4.285.026.3135(21350[⨯+⨯+-=1776.4mm

○3对于第三排弯起钢筋 3h ∆=

1350—[(35+31.6×2+25.1×0.5+28.4)+(43+25.1+25.1×

0.5)]=1130.2mm

弯起钢筋(2N3)的弯起点3距支点中心距离为2339+1130.2=3469.2mm

分配的剪力值为

4199

233924199V V Sb1

Sb3

-+

=h

V Sb3=81.7kN 需要的弯起钢筋为A sb3=

45sin f 33.1333sd V Sb3=550.3mm 2

可供的弯起钢筋为A sb3=760mm 2(2Φ22) 钢筋与梁轴交点到支座中心3'距离为 3469.2-[

)]4.281.255.06.31235(2

1350

+⨯+⨯+-=2933.4mm ○

4对于第四排弯起钢 ()]5.01.251.2543)4.281.255.126.3135[(-13504⨯++++⨯+⨯+=∆h =1105.1mm

弯起钢筋(2N2)的弯起点4距支点中心距离为3469.2+1105.1=4573.3mm

分配的剪力值为

4199

2.346924199V V 1

Sb 4

Sb -+

=h

V Sb4=45.3kN 需要的弯起钢筋为A sb4=

45sin f 33

.1333sd V Sb4=305.1mm 2

可供的弯起钢筋为A sb3=760mm 2(2Φ22) 钢筋与梁轴交点到支座中心4'距离为4573.3-[

)]1.255.14.286.31235(2

1350

⨯++⨯+-=4062.6mm ⑤对于第五排弯起钢

5h ∆=1350-[(35+26.31⨯+28.4+2.5)1.25⨯+(43+25.1+25.1)5.0⨯=1080mm

弯起钢筋(2N1)的弯起点距支点中心距离

4573.3+1080=5653.3mm>4199+675=4874mm,即在欲设置弯筋区域长度以外,故不参加弯起钢筋的计算,画图时可将N1钢筋截断,但实际工程中,一般采取弯起,以加强钢筋骨架施工时的刚度。 将以上所算数据列表计算,如表1-1

表1-1 弯起钢筋计算表

2.4.钢筋弯起后相应各正截面抗弯承载力计算

按照同时满足梁胯间各正截面和斜截面抗弯要求,确定弯起钢筋的位置。由已知跨中截面弯矩计算值2/,l d M =1620kN ⋅m ,支点中心处0,d M =0 以跨中为原

点水平向左为正方向,做出梁的弯矩包络图,在L/4截面处, x=4.5m,L=18m. 弯矩计算值为⎪⎪⎭

⎝⎛⨯-⨯=224

/l 185.4411620M =1215kN ⋅m 与已知值M l/4=1215kN ⋅m 相

比,误差在允许围,故可用)41(M 2

2/,x

d,L

x M l d -=来描述简支梁弯矩包络图是可

行的。(梁的弯矩包络图与抵抗弯矩图见附录2-2) ○

1梁区段:支座中心~1点 截面纵筋2Φ28 A s1 =1232mm 2 有效高度 0h =1350-(35+=)2

6

.311299.2mm 受压区高度 x 1=

'

1

f cd S sd b f A f =14.7mm 正截面抗弯承载力 M u1='f cd b f X1A S1(h 0-x 1/2)=445.5kN ⋅m ○

2梁区段:1点~2点 截面纵筋4Φ28 A s2 =2463mm 2

有效高度 0h =1350-(35+31.6)=1283.4mm 受压区高度 x 2=

'

2

f cd S sd b f A f =29.4mm 正截面抗弯承载力 M u2='f cd b f x 2 (h 0-x 2/2)=875kN ⋅m ○

3梁区段:2点~3点 截面纵筋4Φ28+2Φ25 A s3 =3455mm 2 有效高度 0h =1270.4mm 受压区高度 x 3=

'

3

f cd S sd b f A f =41mm

正截面抗弯承载力 M u3='f cd b f x 3 (h 0-x 3/2)=1202kN ⋅m ○

4梁区段:3点~4点

截面纵筋4Φ28+2Φ25+2Φ22 A s4 =4205mm 2度有效高度0h =1350-

()()3

.12487609822463)

2/1.254.282.6335(7602/4.2826.31359826.31352463=+++++++⨯+++mm

受压区高度 x 4=

'

4

f cd s sd b f A f =50.2mm 正截面抗弯承载力 M u4='f cd b f x 4 (h 0-x 4/2)=1453.9kN ⋅m ○

5梁区段:4点~断筋处 截面纵筋4Φ28+2Φ25+4Φ22 A 5s =4965 mm 2 有效高度0h =1248.3mm 受压区高度 x 5=

'

5

f cd s b f fsdA =59.3mm

正截面抗弯承载力

M u5='f cd b f x 5 (h 0-x 5/2)=1695kN ⋅m ⑥断筋处~跨中

截面纵筋4Φ28+2Φ25+6Φ22 A 6s =5726mm 2 有效高度0h =1236.6mm 受压区高度 x 6=

'

5

f cd s b f fsdA =68.3mm 正截面抗弯承载力 M u6='f cd b f x 5 (h 0-x 6/2)=1926.7kN ⋅m

表1-2钢筋弯起后相应正截面抗弯承载力表

(4)将表1-2的正截面抗弯承载力M ui 在图上用各平行直线表示出来,它们与弯矩包络图的交点分别为k ,l ,m ,n ,q 以各 M ui 值代入 式

)

41(M 22

2/,x

d,L x M l d -=

可分别求出, x1’’=7663mm,x2’’=6104mm,x3’’=4571mm,x4’’=2846mm 2.5.弯起钢筋弯起点位置检查 ○1第一排弯起钢筋(2N5)

其充分利用点m的横坐标x=6104mm ,而2N5的弯起点1的横坐标1

x=L/2-1183.7=7816.3mm,说明弯点1在m点的左侧,且1

x-x-=1712.3mm>h0/2(=641.7mm)。

其不需要点n的横坐标 x =7663mm,而2N5钢筋与梁中轴线交点1'的横坐标1

x’ (=8408.9mm)>7663 mm,符合要求。

○2第二排弯起钢筋(2N4)

其充分利用点l的横坐标 x=4571mm ,而2N4的弯起点2的横坐标

x 2=L/2-2339=6661mm,且x

2-

x=2090mm>h

/2(=635.2mm)。

其不需要点m的横坐标 x=6104mm,而2N4钢筋与梁中轴线交点2'的横坐标

x

2

'(=7973.6mm)>x(=4571mm),符合要求。

○3第三排弯起钢筋(2N3)

其充分利用点k的横坐标 x=2846mm ,而2N3的弯起点3的横坐标

x 3=L/2-3469.2=5530.8mm>x,且x

3-

x=2684.8mm>h

/2(=629.8mm)。

其不需要点l的横坐标x

=

4571mm,而2N3钢筋与梁中轴线交点3'的横坐标

x

3

'(=6066.4mm)>x(=4571mm),符合要求。

○4第四排弯起钢筋(2N2)

其充分利用点不存在,损益不需要检验,满足要求。

综上,钢筋的初步布置满足构造要求。

虽然已经满足构造要求,但是抵抗弯矩图与弯矩包络图之间相差很大,并且为了抗剪的要求还需要进一步的调整弯起点位置,并根据试算增设斜筋,在满足规的前提下,使抵抗弯矩图接近包络图,在弯起钢筋之间曾设直径为16mm的斜筋。(调整后梁的弯矩图与抵抗弯矩图见附录图2-3,梁弯起钢筋和斜筋设计布置图见附录图2-4)

2.6斜截面抗剪承载力的复核

按照《公路桥规》关于复核斜截面位置的规定,本设计需要进行6次截面复核,1处为距支座h/2,1处在箍筋间距变化处,此处取距支座中心1400mm处,4处弯起钢筋弯起点位置,现进行逐一验算:

⑴距支座中心h/2处斜截面抗剪承载力的复核 ○1选定斜截面顶端位置

由图2-5)可知距支座中心为h/2处截面的横坐标为x=9000-675=8325mm,正截面的有效高度为h 0=1299.2mm 。现取斜截面投影长度c'≈h 0=1299.2mm ,那么得到的选择的斜截面顶端位置A ,其横坐标为x=8325-1299.2=7025.8mm 。

2斜截面抗剪承载力复核 A 处正截面的剪力V x =V L/2+(V 0-V L/2)

L

x

2=296.4kN

)

41(M 22

2/,x

d,L x M l d -= =632.8kN ⋅m

A 处正截面有效高度为h 0=1.2834m(主筋为4Φ228) ,广义剪跨比m 及斜截面投影长度c 分别为 m=

x x

V M h =1.66<3,取m=1.66 c=0.6mh 0=1.28m<1.2990m 将要复核的斜截面如图2-5中所示AA'斜截面(图中虚线位置),斜角

β=tan -1(h 0/c) ≈45.10

斜截面纵向受拉主筋有2Φ28(2N6),相应的主筋配筋率 P=100

s

A bh =0.47<2.5 取p=0.47 箍筋的配筋率SV ρ=

V

SV

bS A =0.2%>m in ρ(=0.18%) 与斜截面相交的弯起钢筋有2N5(2Φ28),2N4(2Φ25),斜筋有2N7(2Φ16) AA '的斜截面抗剪承载力为

()

sv sv k cu f f p bh ρααα,0

3

321u 6.02)1045.0(V +⨯=-+()

∑⨯s sb sd A f

θsin 1075.03-

=649kN>x V =296.4kN

故距支座中心为h/2处的斜截面抗剪承载力满足要求。 ⑵第一排钢筋弯起点处斜截面抗剪承载力的复核 ○1选定斜截面顶端位置

由图2-6可知第一排弯起钢筋处截面的横坐标为x=9000-1180=7820mm,正截面的有效高度为h 0=1283.4mm 。现取斜截面投影长度c'≈h 0=1283.4mm ,那么得到的选择的斜截面顶端位置A ,其横坐标为X=7820-1283.4=6536.6mm 。

2斜截面抗剪承载力复核 A 处正截面的剪力V x =V L/2+(V 0-V L/2)

L

x

2=280.6kN

)

41(M 22

2/,x

d,L x M l d -= =765.5kN ⋅m

A 处正截面有效高度为h 0=1.2834m ,广义剪跨比m 及斜截面投影长度c 分别为 m=

x x

V M h =2.13<3,取m=2.13 c=0.6mh 0=1.64m 将要复核的斜截面如图2-6中所示AA'斜截面(图中虚线位置),斜角

β=tan -1(h 0/c) ≈38 0

斜截面纵向受拉主筋有2Φ28(2N6),相应的主筋配筋率 P=100

s

A bh =0.48<2.5 取p=0.48 箍筋的配筋率SV ρ=

V

SV

bS A =0.2%>m in ρ(=0.18%) 与斜截面相交的弯起钢筋有2N4(2Φ28),2N5(2Φ25)斜筋有2N7(2Φ16) AA '的斜截面抗剪承载力为

()

sv sv k cu f f p bh ρααα,0

3

321u 6.02)1045.0(V +⨯=-+()

∑⨯s sb sd A f

θsin 1075.03-

=577.3kN>x V =280.6kN

故此处的斜截面抗剪承载力满足要求

⑶第二排钢筋弯起点处斜截面抗剪承载力的复核 ○1选定斜截面顶端位置

由图2-7可知第二排弯起钢筋处截面的横坐标为x=9000-1180-1600=6220mm,正截面的有效高度为h 0=1270.4mm 。现取斜截面投影长度c'≈h 0=1270.4mm ,那么得到的选择的斜截面顶端位置A ,其横坐标为X=6220-1270.4=4949.6mm 。

2斜截面抗剪承载力复核 V x =V L/2+(V 0-V L/2)

L

x

2=229.5kN

)

41(M 22

2/,x

d,L x M l d -= =1130kN ⋅m

A 处正截面有效高度为h 0=1.2704m ,广义剪跨比m 及斜截面投影长度c 分别为 m=

x x

V M h =3.87>3,取m=3 c=0.6mh 0=2.28m 将要复核的斜截面如图2-7中所示AA'斜截面(图中虚线位置),斜角

β=tan -1(h 0/c) ≈29 0

斜截面纵向受拉主筋有4Φ28+2Φ25(2N6+2N5+2N4),相应的主筋配筋率 P=100

s

A bh =1.36<2.5 取p=1.36 箍筋的配筋率SV ρ=

V

SV

bS A =0.2%>m in ρ(=0.18%) 与斜截面相交的弯起钢筋有2N4(2Φ25),2N3(2Φ22)斜筋有2N7(2Φ16),2N8(2Φ16),则AA '的斜截面抗剪承载力为

()

sv sv k cu f f p bh ρααα,03321u

6.02)1045.0(V +⨯=-+()

∑⨯s sb sd A f

θsin 1075.03-

=523.8kN>x V =229.5kN

结构计算书

结构计算书 一、工程概况 建筑层数:地上7层 建筑高度:22.65米 结构类型:钢筋砼框架结构 总建筑面积:2353.76平方米 设计标高:0.000 建筑类型为商住楼 本设计图除标高及总图以米为单位外,尺寸以毫米为单位。 二、设计要求 结构的设计使用年限:50年建筑结构的安全等级:二级 结构的重要性系数:1.0 建筑抗震设防类别:二类 抗震设防烈度:六度防火类型:二类 耐火等级:二级天面防水等级:二级;二道防水设防 三、结构方案选择 3.1.1 结构选型 1.结构体系:采用钢筋混凝土框架结构 2.屋面结构:现浇钢筋混凝土梁板屋盖 3.楼面结构:现浇钢筋混凝土梁板楼盖 3.1.2 结构布置 1.平面布置 (1)柱网尺寸:根据建筑平面图选择柱网布置方案,确定横向和纵向框架梁的跨度。框架梁的跨度应为柱子轴线之间的距离。 (2)建筑缝的设置:根据混凝土规范及其它要求进行设置。 (3)次梁的布置。 2.竖向布置 框架的层高即为框架柱的长度。首层层高应取基础顶面到首层梁顶的距离,其余各层层高

应取梁顶至梁顶的距离。 3.1.3 主要构件截面尺寸的确定 各构件的截面尺寸应满足承载力、刚度及延性要求,并考虑方便施工。 1.框架梁截面尺寸:框架梁的截面尺寸应该根据承受竖向荷载的大小、梁的跨度、框架的间距、是否考虑抗震设防要求以及选用的混凝土材料强度等诸多因素综合考虑确定。 一般情况下,框架梁的截面尺寸可参考受弯构件按下式估算:梁高h=(1/8~1/12)l ,其中l 为梁的跨度。梁宽b=(1/2~1/3)h 。在抗震结构中,梁截面宽度不宜小于200mm ,梁截面的高宽比不宜大于4,梁净跨与截面高度之比不宜小于4。 2.框架柱截面尺寸:框架柱的截面形式通常大多为方形、矩形。柱截面的宽与高一般取层高的1/15~1/20,同时满足 25/0l h ≥、30/0l b ≥,l0为柱计算长度。多层房屋中,框架柱截 面的宽度和高度不宜小于300mm ;高层建筑中,框架柱截面的高度不宜小于400mm ,宽度不宜小于350mm 。柱截面高度与宽度之比为1~2。柱净高与截面高度之比宜大于4。 为了减少构件类型,简化施工,多层房屋中柱截面沿房屋高度不宜改变。 在计算中,还应注意框架柱的截面尺寸应符合规范对剪压比(0/c c c c h b f V )、剪跨比 ( c Vh M /=λ)、轴压比(c c c N h b f N /=μ)限值的要求,框架柱截面尺寸: 柱尺寸由轴压比确定: []μμ≤= A f N c c 式中, N ——柱轴力设计值。根据荷载面积法确定: 2125.1ββω????=n S N S:柱的负荷面积 ω:单位面积重量,轻质隔墙体取2/10m KN n :计算截面以上层数。 1β:一级、二级抗震设计角柱为1.3,其它情况为1.0。 2β:由于水平力使轴力增大系数,6、7度抗震设计为1.05。 c μ——柱的轴压比;

结构设计原理计算书 简支T型梁

钢筋混凝土简支T梁桥主梁配筋设计计算书 专业: 班级: 学号: 姓名:

(一)基本技术资料 标准跨径:20.00m; 主梁全长:19.96m; 计算跨径:19.50m; 桥面净宽:净—7m+2*0.75m=8.5mc; 设计荷载:汽车荷载采用公路—B级,人群荷载3kN/m2; 主梁纵横面尺寸:见图1、图2; 图1主梁横断面图(单位:mm)

图 2 主 梁 纵 断 面 图 (单位:mm) 主 梁 中 线支 座 中 心 线 梁控制截面的作用效应设计值: (1)用于承载能力极限状态计算的作用效应组合设计值 跨中截面弯矩组合设计值1, 2 1892.74d M KN m =?,其他各截面弯矩可近似按抛 物线变化计算。 支点截面剪力组合设计值 ,0367.2d V KN =,跨中截面剪力组合设计值 1,2 64.2d V KN =,其他截面可近似按直线变化计算。 (2)用于正常使用极限状态计算的作用效用组合设计值(梁跨中截面) 恒载标准值产生的弯矩750GK M KN m =? 不计冲击力的汽车荷载标准值产生的弯矩 1562.4Q K M KN m =? 短期荷载效应组合弯矩计算值为 1198.68S M KN m =? 长期荷载效应组合弯矩计算值为 1002.46l M KN m =? 人群荷载标准值产生的弯矩值为 255Q K M KN m =? 材料要求: (1)梁体采用C25混凝土,抗压设计强度 11.5cd f Mpa =; (2)主筋采用HRB335钢筋,抗拉设计强度280sd f Mpa =。

(二) 截面钢筋计算 一、 跨中截面的纵向受拉钢筋的计算 由设计资料查附表得11.5cd f Mpa =, 1.23td f Mpa =280sd f Mpa =,0.56b ξ=, 0 1.0 γ=,弯矩计算值 01, 2 1892.74d M M KN m γ==? 1、计算T 形截面梁受压翼板的有效宽度: 180 80 180 (a)(b) 图2 跨中截面尺寸图(尺寸单位:mm ) 为了便于计算,将图2(a )的实际T 型截面换算成图2(b )所示的计算截面 80140 1102 f h mm '= += 其余尺寸不变。

第二组桥梁结构设计计算书

一、设计要求 竞赛模型为木质单跨桥梁结构,采用木质材料制作,具体结构形式不限。 1.几何尺寸要求 (1) 模型长度:模型有效长度为1200mm,两端提供竖向和侧向支撑。对于竖向支撑,每边支撑长度为0-70mm。 (2)模型宽度:在模型有效长度范围内(中央悬空部分),模型宽度应不小于180mm,最宽不应超过300mm;在支座范围内,宽度不限,但不应超过320mm 。 (3) 模型高度:模型上下表面距离最大位置的高度不应超过400mm;为方便小车行驶,中央起拱高度不应超过40mm;端部支座位置处的高度不应超过150mm。 2.结构形式要求 对于结构形式没有特定要求,桥面设置两个车道,每个车道宽不得小于90mm,车道之间不能有立柱、拉索一类的构件。 结构可以仅采用竖向支撑的方式,也可以采用竖向和侧向同时支撑的方式来实现约束。 3.材料 (1)木材:用于制作结构构件。有如下两种规格: 木材规格(单位:mm)材料 2 mm×2 mm×1000mm桐木 2 mm×4 mm×1000mm 桐木 2 mm×6 mm×1000 mm桐木 4 mm×6 mm×1000mm桐木 1 mm×55 mm×1000 mm桐木 木材力学性能参考值:顺纹弹性模量1.0×104MPa,顺纹抗拉强度30Mpa。 (2) 502胶水:用于模型结构构件之间的连接。 二、结构选型 拱桥桥梁的基本体系之一,建筑历史悠久,外形优美,古今中外名桥遍布各地,在桥梁建筑中占有重要地位。它适用于大、中、小跨公路或铁路桥,尤宜跨越峡谷,又因其造型美观,也常用于城市、风景区的桥梁建筑。 根据不同的分类标准,可以分为不同的类型。 按拱圈(肋)结构的材料分:有石拱桥(见石桥)、钢拱桥、混凝土拱桥、钢筋混凝土拱桥。 按拱圈(肋)的静力图式分:有无铰拱、双铰拱、三铰拱(见拱)。前二者属超静定结构,后者为静定结构。无铰拱的拱圈两端固结于桥台(墩),结构最为刚劲,

结构计算书最终版

土木工程毕业设计计算书 院系:城市建设学院 指导老师: 学生姓名: 完成日期:

摘要 本毕业设计题目是孝感市第一高级中学教学楼五层钢筋混凝土框架结构体系,该教学楼的总建筑面积大约是4571.84平方米,共五层,底层层高为3.9m,标准层层高为3.6m。本建筑采用钢筋混凝土全现浇框架结构体系。基础采用柱下独立基础。 本设计内容包括建筑设计、结构手算和两部分。其中建筑设计主要根据建筑的重要性,工程地质勘查报告,建筑场地的类别及建筑的高度和层数来确定建筑的结构形式,本工程采用的是框架结构。 手算部分计算书的主要内容有工程概况、构件尺寸的初步确定、框架的计算简图、荷载计算、框架横向侧移计算、框架在水平风载、竖向荷载作用下的内力计算分析和计算、内力组合、截面设计、楼梯设计及基础设计。其中计算水平地震力作用下时采用极限状态设计方法。在梁柱截面设计时要采用“强柱弱梁”原则。 在设计过程中采用了手算和电算两种方式,对计算结果进行校核,及时发现设计中的错误以及与电算不同的部分,找出原因。 关键词:毕业设计,教学楼,框架结构,内力组合,截面设计

ABSTRACT The graduation design topic is the five floor’s reinforced concrete frame of the No. 1 middle school in Xiaogan City. The total construction area of the teaching building is about 4571.84 square meters ,it has five floors , the height of the bottom floor is 3.9m,the height of the standard floor is 3.6m. The building is used cast-in-place reinforced concrete frame .And the building foundation is used an independent under-post foundation. The design includes architectural design, structural calculation. Architectural design bases on the importance of the building, engineering geological survey report, the type of construction sites, the height of the building and the number of the floors to determine the building’s struc ture, this project uses a frame structure. Hand-counted part of the calculations’ main contents include project profiles, component dimensions of the initially identified ,the framework of the structure calculation diagram ,load calculation ,calculation of the framework of horizontal lateral, the framework contained in the horizontal wind ,vertical load calculation ,analysis and calculation of internal forces ,internal force composition, cross section design, stair design and basic design. When we consider the calculation of the level of earthquake force ,we should use limit state design method. In the beam and column design ,we should obey the principle of “strong column and weak beam”. In the process of designing ,we use hand and computer computation to check the result, then we can find the errors of designing and the different part of computing ,and we will know the reasons. Key words :graduate design, teaching building, frame structure, internal force composition, cross section design.

结构设计计算书

附件1:编制要求 结构设计计算书编制基本要求 计算书的正确、有效、可靠性是确保施工图设计质量的重要和必要的条件。为便于广大建筑结构设计人员规范有效地编写计算书,根据建设部2003年4月颁布的《建筑工程设计文件编制深度规定》,结合目前我市各设计单位在建筑工程设计计算书编写中存在的问题,提出关于建筑结构计算书编制的基本要求,并在此基础上编制了《结构设计计算书推荐文本》,供设计人员参考使用。各设计单位可结合本行业、本单位特点对计算书推荐文本进行必要的优化与调整。 结构设计计算书编制基本要求由以下几个方面组成: 一、计算书依据与条件 结构计算书编写内容主要包括以下几个方面: 1.设计依据:主要设计规范、规程(包括国标、行标和省标以及地方标准等)。 2.设计参数:安全等级、结构类型、抗震设防分类、抗震设防烈度、地震动峰值加速度、抗震等级、基本风压、雪压、场地类别等。 3.相关依据: 采用的计算软件名称、版本号、选用的勘察报告、以及专家论证等其他需要特别说明的事项。 4.荷载取值:(1)屋面荷载计算(包括屋面自重、屋面活载以及屋面设备荷载等);(2)楼面荷载计算:(包括楼板自重、楼面活载、楼面设备荷载、楼面上隔墙荷载、楼面下吊挂荷载、±0.00处可能堆放荷载等);(3)墙体荷载(包括不同材料、不同厚度以及不同高度墙体的每延米自重计算);(4)风荷载;(5)地下室主要荷载;(6)其它各类附加在结构上的设备等荷载(如吊车荷载等)。 二、计算书深度 计算书的编制深度要求如下: 1.计算书内容应完整清楚,计算步骤要条理分明,必要时应给出平面布置简图和计算简图。2.选用的参数或引用数据应有可靠依据;采用计算图表及不常用计算公式时,应注明来源出处;对公式中属于可有选择范围的系数或参数,应对其作出说明。 3.选用标准图集时,工程条件应符合图集所设定的适用范围,给出构件实际承受荷载标准值(或设计值)及所选构件允许 荷载值。如确需进行局部调整时,应根据图集的有关规定,结合工程实际进行必要的复核验算。该部分的计算应作为计算书的有效内容。 4.计算分析所采用计算理论应符合工程结构体系实际受力状态,计算模型应根据结构构件实际情况确定,建有多个结构计算模型时,应对各结构计算模型分别进行说明;计算简图应符合受力及边界约束条件;构件编号应与图纸一致,以便核查。 5.对电算结果,应经判断和校核;在确认其合理有效后方可采用。特殊结构以及重要结构应进行手算复验或采用不同力学模型的结构分析软件进行验算。 6.对计算结果有较大调整或修改时应有说明;对调整或修改后的相关结构构件应重新进行计算,对已经作废的计算内容应予以剔除,并由校对、审核人重新确认。 三、计算书格式 1.计算书除计算机打印外,应用钢笔或签字笔书写;不应使用圆珠笔、铅笔等不利保留的用笔。书写应清楚、整洁,并能满足校对审核及工程归档要求。 2.所有计算书必须进行校审,设计人(计算人)对自己的 计算结果应先自校,校对人(审核人)宜按本单位规定的专用符号对计算正确结果作出标记;对校审意见应有处理结果,计算错误部分由原设计人(计算人)修改后,应再次进行校审;

结构设计计算书

结构设计计算书 一:设计概况 1.建设项目名称:综合办公楼(集购物,餐饮,娱乐,办公,旅馆于一体) 2.建设地点:给定地基三 3.设计资料: 3.1.地质水文资料:根据工程地质勘测报告,拟建场地地势平坦,二类场地,表面为平均厚度1.0m 左右的素填土,以下为3.0m 左右的沙质粘土,承载力的特征值为220 kN/m 2,再下面为厚约5-7米的砾层,其承载力的特征值为300kN/m 2。 地下水位距地表最低为-12m,无侵蚀性,对建筑物基础无影响。 3.2.气象资料: 全年主导风向:西北风 夏季主导风向:东南风 基本风压为:0.35kN/m 2(B 类场地) 基本雪压为:0.25kN/m 2 3.3.抗震设防要求:七度三级设防 3.4.底层室内主要地坪标高为±0.000,室外地面标高-0.450米。 二.结构计算书 1.结构布置方案及结构选型 1.1.结构承重方案选择 根据建筑功能要求以及建筑施工的布置图,本工程确定采用框架承重方案,框架梁、柱布置参见结构平面图。 1.2.主要构件选型及尺寸初步估算 主要构件选型 (1)梁﹑板﹑柱结构形式:现浇钢筋混凝土结构 (2)墙体采用:混凝土空心砌块(重度12KN/平方米) (3)墙体厚度:外墙:240mm ,内墙:240mm (4)基础采用:柱下独立基础 1.3.主要构件选型及尺寸初步估算 主要构件选型 横梁300*600,纵梁300*600,次梁CL1,CL2 :300×500,CL3 200×400,CL4 200×300(混凝土C30 fc =14.3MP ,ft =1.43MP ) 柱截面尺寸估算:该框架结构抗震等级为三级,轴压比限值为0.9(混凝土C35, fc =16.7,ft =1.57) 边柱mm mm mm f N A c 4234233.1793537.169.01000 *8*12*0.3*2.7*3.12?==?=≥μ 中柱mm mm mm f N A c 6066063.3676747 .169.01000 *8*12*15.6*2.7*3.12?==?=≥ μ

结构设计计算书

结构设计计算书 1.建筑设计 1.1 工程概况 (1)工程名称:某中学办公楼 (2)建筑面积:总建筑面积约2819.71平方米。 (3)建筑等级:耐久等级为II级。 (4)结构体系:钢筋混凝土框架结构,现浇梁板柱。 1.2 设计容: (1)一层设大、小会议室,接待室各1间,传达室1间。二、三、四层布置与一层基本相同具体布置详见设计图建施03。每层设男女卫生间一间。其余房间为办公室。 (2)设计标准:一般标准的公用建筑。 1.3 设计条件: (1)气温:常年气温-10℃——36℃。 (2)主导风向:夏季西南风,冬季东北风。 (3)基本风压:0.45KN/m2。 (4)基本雪压:0.2KN/m2。 (5)地震基本烈度:6度。 (6)最大冻深:-0.5m。 (7)地下水位:最高地下水位距地面6m,最低地下水位距地面9m,无侵蚀性。 1.4 设计原则: 按照任务书分析和规模的规定,本着设计标准化、施工机械化的原则进行设计时,尽可能的采用标准图集,并考虑施工方便,柱网采用钢筋混凝土框架结构。 1.5 平面设计: (1)房间安排:根据设计任务书要求,每层设有办公室、会议室。总建筑面积为2819.71平方米。每层设置两个厕所、两部楼梯。 (2)厕所布置:厕所位于通风良好的位置,最远的房间距离厕所不大于规规定的50m,以满足使用要求。 (3)楼梯:为了达到防火的要求设了两部楼梯,踏步宽度300mm,踏步高度150mm,每跑11个踏步。 (4)采光要求:所有房间窗地比均大于1/5,满足采光要求。 1.6 立面设计

设计思路:本建筑正立面和侧立面均采用平面柱子不突出的设计,使其达到美观,整洁,活泼的气氛。门窗均居中设置,整齐统一,给人以轻巧,舒适的感觉。 1.7 建筑做法说明 (1)屋面:防水层:三毡四油上铺小石子 找平层:20mm厚1:2水泥砂浆 找坡层:120mm厚水泥焦渣 结构层:120mm厚现浇钢筋混凝土楼板 吊顶:铝合金龙骨吊顶 (2)楼面:防水层:20mm厚磨光花岗石板; 找平层:20mm1:2水泥砂浆找平层; 找坡层:10 mm厚刷素水泥浆; 结构层:120 mm现浇混凝土楼板; 吊顶:铝合金龙骨吊顶。 (3)外墙:7厚1:3水泥砂浆打底扫毛; 7厚1:2.5水泥砂浆罩面抹平: 刷(喷)涂料 (4)墙:9厚水泥砂浆抹面 7厚1:3水泥砂浆打底扫毛 7厚1:3水泥砂浆找平扫毛 6厚1:2.5水泥砂浆压实抹光 喷墙涂料 (5)混凝土水泥散水:50厚C15混凝土撒1:1水泥砂浆压实赶光 150厚3:7灰土夯实 素土夯实 (6)屋面顶棚:刷素水泥浆一道 9厚1:0.3:3水泥石灰膏砂浆打底扫毛 9厚1:0.3:2.5水泥石灰膏砂浆罩面 满刮腻子一遍及乳胶漆 (7)卫生间楼面:10厚铺地砖,稀水泥浆填缝结合层 撒素水泥面(撒适量清水) 25厚1:2干硬性水泥砂浆结合层

结构设计原理课程设计计算书

第一部分:钢筋混凝土 一、设计资料 某二层框架结构,柱网布置见附图1。底层层高3.9m ,二层层高4.5m ,基础顶面 到室内距离0.635m ,框架柱截面尺寸为450mm 450mm ?,结构安全等级为二级,环境类别为一类。 面层做法:按江苏省标准图集苏J01-20057/3采用水磨石楼面(15mm 厚水磨石面层,20m 水泥砂浆打底,荷载标准值取2 0.65kN /m );该楼盖无其它特殊要求。设计时按双向板楼盖设计。 顶棚处理:20厚混合砂浆抹灰,荷载标准值取20.3kN/m 。 活载取值:26.2kN/m k q = 材料选用:C30混凝土;梁内纵向受力钢筋采用HRB400,其余钢筋均采用 HRB335。( L18100mm =, L 29000mm =) 二、设计计算内容 1 确定结构平面布置图 2 板的设计(3.865标高楼板,弹性方法) (1) 板的内力计算 (2) 强度计算 (3) 绘制配筋图 3. 次梁设计(3.865标高次梁,弹性方法) (1) 内力计算 (2) 强度计算 (3) 绘制配筋图 4. 主梁设计 (3.865标高③轴主梁,弹性方法) (1) 内力计算 (2) 强度计算 (3) 选配钢筋、绘制材料抵抗弯矩图及配筋图 三、设计过程 1. 结构平面布置图(见图1) 2. 楼板计算 (1)尺寸估算 ① 由于主梁两端均与柱刚接,按弹性理论设计。主梁计算长度09000mm c l l == 查表,主梁001.2 /10~/15 1.29000/10~9000/151080~720mm h l l ==?=()(),取900mm h =; 宽度/3~/2900/3~900/2300~450mm b h h ===,取350mm b =;

结 构 计 算 书

人防墙体结构计算书 一、临空墙 按核六级荷载取值: qe=130KN/㎡,层高L=4800mm,墙厚h=350mm 1、弯矩: M=1/12×qL2=1/12×130×4.8×4.8=249.6KN.m 2、材料强度: C30砼f c=14.3N/㎜2,三级钢f y=360 N/㎜2 f cd=14.3×1.5=21.45 N/㎜2, f y=360×1.20=432 N/㎜2 3、配筋计算: 截面尺寸 b×h=1000×350 αs=M/f cd bh02=249.6×106/21.45×1000×325×325=0.11 γs=0.5{1+ (1-2αs )1/2}=0.94 A s=M/γs1f y h0=249.6×106/0.94×432×325=1891㎜2 实配£ 18@100,A s=2544㎜2 二、外围护墙 按核六级荷载取值: q e=10KN/㎡(非饱和碎石土) 土压力q1=60KN/㎡ 水压力q2=15KN/㎡ 层高L=4800mm,墙厚h=350mm

1、弯矩: M=1/12×(q e+q1+q2)×L2=1/12×85×4.8×4.8=163KN.m 2、材料强度: C30砼f c=14.3N/㎜2,三级钢f y=360 N/㎜2 f cd=14.3×1.5=21.45 N/㎜2, f y=360×1.20=432 N/㎜2 3、配筋计算: 截面尺寸 b×h=1000×350 αs=M/f cd bh02=163×106/21.45×1000×325×325=0.071 γs=0.5{1+ (1-2αs2) 1/2}=0.96 A s=M/γs f y h02=163×106/0.96×432×325=1209㎜ 实配£ 16@150,A s=1340㎜2

结构计算书范文

结构计算书范文 结构计算是指对建筑或工程结构进行力学分析和计算的过程。它是结构设计的重要环节,为确保结构安全和合理,以及满足建筑或工程的使用需求提供了理论依据和技术支持。结构计算书是结构计算的结果文件,记录了对结构进行力学分析和计算的过程、方法和结果。 1.结构基本信息:包括结构的类型、形式、尺寸、材料、节点布置等基本信息。这些信息是进行结构计算的基础,也是后续步骤的依据。 2.力学模型:结构计算需要建立相应的力学模型,通常包括几何模型和材料模型。几何模型要准确描述结构的形状和尺寸,材料模型要正确描述材料的力学性质,如弹性模量、抗拉强度、屈服强度等。 3.荷载计算:荷载计算是结构计算的重要步骤,用于确定结构所承受的荷载大小和作用方向。荷载包括静载和动载,静载包括自重、活载和附加载荷等,动载包括风载、地震载荷等。 4.抗力计算:抗力计算是根据荷载大小和作用方向,计算结构受力情况,包括内力、弯矩、剪力等。抗力计算要满足结构的强度和刚度要求,确保结构在荷载作用下不发生破坏。 5.稳定性分析:稳定性分析主要用于评估结构在外力作用下的稳定性和安全性。常用的稳定性分析方法有弹性稳定性分析、弹塑性稳定性分析等。 6.疲劳分析:疲劳分析用于评估结构在反复荷载下的疲劳性能。疲劳分析要确定结构的疲劳荷载谱,以及结构的疲劳寿命。

7.地震分析:地震分析用于评估结构在地震作用下的响应和安全性。地震分析要确定地震波的特性和结构的动力特性,进而分析结构的地震反应。 8.实验验证:实验验证是通过对结构进行物理试验,验证结构计算的结果和假设的正确性。实验验证可以用于验证结构的安全性和有效性,提高结构的设计质量。

建筑结构计算书

建筑结构计算书 1. 背景信息 该文档是为了提供建筑结构计算的详细信息和结果。它包含必要的计算和设计参数,以便评估建筑结构的强度和稳定性。 2. 建筑结构计算方法 我们遵循以下步骤进行建筑结构计算: 1. 收集建筑结构的基本信息,例如建筑物尺寸、荷载条件等。 2. 根据荷载情况选择适当的结构材料,例如钢筋混凝土或钢结构。 3. 使用相关的结构计算方程和公式计算建筑结构的强度和稳定性。 4. 通过验证计算结果与适用的建筑结构设计规范相比较来评估建筑结构的安全性。 5. 根据计算结果调整设计参数,如果需要重新计算直到满足安全要求为止。 3. 计算内容 建筑结构计算书中包含了以下各个计算部分的详细结果:

1. 荷载计算:计算建筑物所承受荷载的大小和位置。 2. 结构材料计算:根据荷载和结构要求计算所需的结构材料的尺寸和强度。 3. 梁和柱的计算:计算梁、柱的截面尺寸和强度,以确保其能够承受设计荷载。 4. 地基计算:计算地基底面积和深度,以确保地基能够稳定地支撑建筑物。 4. 结果分析 建筑结构计算书中的计算结果将被详细呈现,其中包括结构材料尺寸、截面尺寸、强度、荷载分布图等。我们将对计算结果进行分析,确认结构的安全性。 5. 结论 建筑结构计算书提供了用于评估建筑结构强度和稳定性的详细计算结果和参数。这些结果将帮助您进行建筑结构的合理设计和评估,从而确保建筑物的安全性和稳定性。 This ___ analysis for a building. It includes ___ of the structure. The document ___ ns, material ns, beam and column ns, and ___. The

结构计算书范本

广东省建筑设计研究院深圳分院 结构设计技术条件 工程名称:广州江东花园住宅小区(第一期)设计号:01-015(1-2) 兴建单位:广州江东房地产开发有限公司 1.工程概况 本项目为广州江东花园住宅小区(第一期),位于广州天河区东圃镇北面,广东奥林匹克体育中心西侧,东临东环高速公路,西至河道及广州氮肥厂中学,北达黄洲路,总用地面积为230000m2,区内为多栋6~18层住宅楼及会所,商场等多层附属设施,总建筑面积为179300m2,其中中心庭园内有一层地下室,为停车库及设备房,兼战时六级人防。地下室露出建筑物轮廓线部分覆土深2米。地下一层层高3.7m,A型住宅首层架空并设梁式转换,层高4.5m,其余住宅楼层标准层层高均为2.9m。住宅楼层最高为A型,共18层,平面尺寸为16.85m×27.0m,高宽比为53.8/16.85=3.19,长宽比为27.0/16.85=1.60,其余均为较规则建筑。 2.设计主要依据和资料 建筑结构设计统一标准GBJ68-84 建筑结构荷载规范GBJ9-87 混凝土结构设计规范(1993年及1996年局部修订)GBJ10-89 建筑抗震设计规范(1993年局部修订)GBJ11-89 建筑地基基础设计规范GBJ7-89 钢筋混凝土高层建筑结构设计与施工规程JGJ3-91 建筑桩基技术规范JGJ94-94 建筑抗震设防分类标准GB50223-95 中国地震烈度区划图1990年版 广东省非承重砼小型砌块砌体工程技术规程DBJ/T15-18-99 广东省建筑结构荷载规定DBJ15-2-90 广东省建筑地基基础设计规范DBJ15-3-91 广东省预应力混凝土管桩基础技术规程DBJ/T15-22-98 建筑基坑支护技术规程JGJ120-99 广州地区建筑基坑支护技术规定GJB02-98 人民防空地下室设计规范GB50038-94 冷轧带肋钢筋砼结构技术规程JGJ95-95 钢筋焊接网混凝土结构技术规程JGJ/T114-97 高层民用建筑设计防火规范(1997年局部修改)GB50045-95 建筑设计防火规范(修订本)GBJ16-87 工程建设标准强制性条文(房屋建筑部分) 结构设计统一技术措施——广东省建筑设计研究院 工程地质勘察报告——由广东省地质建设工程勘察院提供 3.结构体系、抗震等级及防火要求 1)本工程住宅楼采用短肢剪力墙结构体系,公建及会所采用框架结构体系,剪力墙抗震等级为二级,框架抗震等级为三级。短肢墙轴压比≤0.6,转换大梁以下框支柱 抗震等级为二级,轴压比≤0.7。

结构设计原理课程设计计算书

结构设计原理课程设计计算书结构设计原理课程设计计算书中国矿业大学力学与建筑工程学院《结构设计原理》课程设计第24 页第一部分:钢筋混凝土一、设计资料某二层框架结构,柱网布置见附图1。 底层层高,二层层高,基础顶面到室内距离,框架柱截面尺寸为,结构安全等级为二级,环境类别为一类。 面层做法: 按江苏省标准图集苏采用水磨石楼面(厚水磨石面层,水泥砂浆打底,荷载标准值取);该楼盖无其它特殊要求。 设计时按双向板楼盖设计。 顶棚处理: 厚混合砂浆抹灰,荷载标准值取。 活载取值: 材料选用: 混凝土;梁内纵向受力钢筋采用,其余钢筋均采用。(,)二、设计计算内容1 确定结构平面布置图2 板的设计(3.865标高楼板,弹性方法)(1)板的内力计算(2)强度计算(3)绘制配筋图3. 次梁设计(3.865标高次梁,弹性方法)(1)内力计算(2)强度计算(3)绘制配筋图 4. 主梁设计(3.865标高③轴主梁,弹性方法)(1)内力计算(2)强度计算(3)选配钢筋、绘制材料抵抗

弯矩图及配筋图三、设计过程1. 结构平面布置图(见图1)2. 楼板计算(1)尺寸估算①由于主梁两端均与柱刚接,按弹性理论设计。 主梁计算长度查表,主梁,取;宽度,取;图1 楼盖结构平面布置图②由于次梁两端均与主梁整浇,按弹性理论设计。 次梁中间跨计算长度;次梁边跨计算长度。 查表,次梁,取。 宽度,取。 ③由于楼板两端均与主梁整浇,按弹性理论设计。 计算跨度(C、D区隔),(A、B区隔),。 各区板的计算跨度见表1。 查表,楼板,考虑到楼面活荷载比较大及其他影响,取。 (2)荷载计算荷载标准值面层水磨石楼面结构层厚楼板平顶恒载标准值活载标准值荷载设计值由可变荷载控制的组合由永久荷载控制的组合故荷载设计值由可变荷载效应控制,板内力计算时取3)内力计算双向板按弹性理论计算内力,在求各区板内最大弯矩时,按恒荷载满布及活荷载棋盘式布置,取荷载: 在作用下,各支座可视为固定,某些区隔板跨内最大正弯矩不在板的中心点处;在作用下,各区格板四周均可视为简支,跨内最大正弯矩则在板的中心点处,计算时可近似取二

结构设计原理课程设计计算书

一、 设计目的与要求 (1) 掌握钢筋混凝土简支梁正截面和斜截面承载力的计算方法 (2) 并熟悉内力包络图和材料图的绘制方法 (3) 了解并熟悉现梁的有关构造要求 (4) 掌握钢筋混凝土结构施工图的表达方式和制图规定,进一步提高制图的基本技能 二、 设计题目 装配式钢筋混凝土简支梁设计 三、 设计资料 T 型截面梁的尺寸如图所示,梁体采用C 25混凝土,主筋采用HRB 400级钢筋,箍筋采用R 235级钢筋。简支梁计算跨径L 0=24M 和均布荷载设计值=40KN/M 。 跨中截面:M dm = 18×q 2b l =18 ×42×242 =3024KN ·M m d V =0 L/4截面:M dl = 332×q 2b l =3 32 ×48×202=1800KN ·M 支点截面:M d0=0 0d V = 1 2 q l b =504KN 四、 设计内容 (1) 确定纵向受拉钢筋数量及腹筋设计。 (2) 全梁承载能力图校核。 (3) 绘制梁截面配筋图。 (4) 计算书:要求计算准确,步骤完整,内容清晰。 五、 准备基本数据 由查表得: C25混凝土抗压强度设计值f cd =11.5MPa,轴心抗拉强度设计值f td =1.23MPa 。 混凝土弹性模量E c =2.80×104 MPa 。 HRB 400级钢筋抗拉强度设计值f Sd =330MPa, 抗压强度设计值f 'Sd =330MPa 。 R 235级钢筋抗拉强度设计值f Sd =195MPa, 抗压强度设计值f 'Sd =195MPa 。 六、 跨中正截面钢筋设计

1、 确定T 型截面梁受压翼板的有效宽度/f b 由图所示的T 型截面梁受压翼板的宽度尺寸为其等效的平均厚度/f h = 14080 2 =110mm /1f b =13 L 0=1 3 ×24000=8000 /2f b =1580mm(相临两主梁轴线间距离) /3f b =b +2b h +12/f h =200+12×110=1520mm 受压翼板的有效高度为: /f b =M in (/1f b ,/2f b ,/3f b )=1520mm ,绘制T 型梁的计算截面如图所示 2、 钢筋数量计算 查附表得受压高度界限系数ξb =0.56 (1) 确定截面有效高度 设a s =120mm ,则h 0=h -a s =1300-120=1180mm (2)判断截面类型 f cd /f b / f h (h 0 - /2 f h )=11.5×1520×110×(1180- 110 2 )=2163.15 KN <3024KN ·M 属于第Ⅱ类T 型梁截面 (3) 确定受压区高度X 由公式r 0M d = f cd b x (h 0-2 x )+ f cd (/f b -b)/ f h (h 0-/ 2f h )得 1.0×3024×106 =11.5×200X ×(1180-2 x )+11.5×(1520-200)×110×(1180-110 2) 即:X 2 -2360X+9960652.174=0 解得X=550.45 mm <ξb h 0=0.56×1180=660.8 mm 且X>/ f h =110mm (4) 求受拉钢筋面积A s 由公式f cd b x+ f cd (/ f b -b)/ f h =f Sd A s 得 A s = /fcd bx+ fcd ( -b) fsd f b

混凝土结构设计原理课程设计计算书

某二层建筑物,为现浇混凝土内框架结构(中间为框架承重,四周为墙体承重),试对楼盖、屋盖、楼梯、雨棚等进行结构设计,并根据设计结果,对混凝土和钢筋用量进行分析。 2、设计资料 1.建设地点:烟台市莱山区 2.楼面做法:水磨石地面,钢筋混凝土现浇板,20mm石灰砂浆板底抹灰。 3.层高: 4.5m;门:宽×高=3300mm×3000mm;楼梯位置见图,楼梯尺寸自定;L1=L2=6000mm; 4.柱截面尺寸为450mm×450mm,墙体为370mm砖砌体; 5.建筑用途:光学加工;活荷载:均布活荷载标准值(板,次梁,主梁)5.0/5.0/4.0(kN/m2),屋面 雪荷载按烟台地区考虑,为0.4 kN/m2; 6.混凝土强度等级C25;梁内受力钢筋为HRB335,板为HPB300,箍筋HPB300。 3、楼盖的结构平面布置 确定主梁沿横向布置,次梁沿纵向布置,主梁与次梁的跨度相同,为L1=L2=6.0m。主梁每跨内布置2 根次梁,6.0/2.0=3≥3,故板按跨度2.0m的单向板进行设计。 板厚:按跨高比条件,要求板厚h≥2000/40=50mm,取板厚h=80mm。 次梁截面尺寸:截面高度应满足h=l0/20~l0/12=300~500mm,取h=450mm;由h/b=2.0~3.0,截面宽取b=200mm。 主梁截面尺寸:截面高度应满足h=l0/14~l0/8=430~750mm,取h=600mm;由h/b=2.0~3.0,截面宽取b=300mm。 综上,布置图如上图所示,楼梯雨棚图另详。

如上图所见,除轴线②-⑤的板属于中间区格单元板外,其余为端区格单元板。 (1)荷载设计值 板的恒荷载标准值: 水磨石面层 0.65kN/m 2 80mm 钢筋混凝土板 0.08×25=2kN/m 2 20mm 石灰砂浆板底抹灰 0.02×17=0.34kN/m 2 小计 2.99kN/m 2 板的可变荷载标准值 5kN/m 2>4 kN/m 2 由于主梁的约束作用 ′ 5.49 kN/m 2 ′ kN/m 2 由可变荷载控制时,永久荷载分项系数γG =1.2,可变荷载分项系数γQ =1.3 由永久荷载控制时,永久荷载分项系数γG =1.35,可变荷载分项系数γQ =1.3 故取值p= (2)计算简图 次梁截面为 ,现浇板在墙上的支承长度不小于120mm ,取板在墙上的支承长度为240mm 。 因为q/g=2.99/5=0.598>0.3,所以按塑性内力重分布设计,板的计算跨度: 边跨 中间跨 因跨度小于10%,可按等跨连续板计算。取1m 宽板带作为计算单元,计算简图如图所示。 (3)弯矩设计值 由规范可查得,板的弯矩系数 分别为:边跨跨中,1/11;离端第二支座,-1/11;中间跨跨中,1/16;中间支座,-1/14。故 对端区格单向板 p=9.84kN/m 2

结构原理设计计算书2计算书2

结构原理设计计算书2计算书2 LT

1.正截面计算 1.1.设计内容:装配式钢筋混凝土简支梁。桥梁处于Ⅰ类环境条件,安全等级为二级0γ=1,梁承受均布荷载q=40kN/m. 1.2.截面尺寸. 钢筋混泥土的简支梁计算跨径L=18m 。T 形截面梁的尺寸如图 1.1,梁肋宽度b=200mm,翼板宽度为1750mm,翼板边缘厚度为100mm,翼板中间处厚度为150mm 1.3.材料规格 梁体采用C30混凝土,轴心抗压强度的设计值为cd f =13.8MPa ,轴心抗拉强度设计值td f =1.39MPa 。主筋采用HRB335的钢筋。抗拉强度设计值为f ' sd =sd f =280MPa 。箍筋采用R235级钢筋。直径8mm,其抗拉强度设计值为sd f =195Pa,抗压强度设计值f ' sd =195Pa. 1.4荷载取值计算 跨中截面 2/,l d M =82 ql =1620kN ⋅m 2/,l d V =70kN 1/4跨截面 2/,l d M =1215kN ⋅m 支点截面 0,d M =0 0,d V =2 ql =360kN

1.5.跨中截面纵向受拉钢筋计算 (1)T 形截面的受压翼板的有效宽度f b ' ○1简支梁跨径的L/3处 由图1-1所示的T 形梁截面受压翼板厚度的尺寸,可得翼板平均厚度f h '=1252 150100=+mm, 1f b '=1/3L=6000mm ○2='2'f b b+2h b +12f h =1700mm ③设相邻两主梁间的平均间距1800' 3'=f b mm,取三者中的最小值,故取受压翼 板的有效宽度为f b '=1700mm 。 (2)钢筋数量的计算 已知预制钢筋混凝土简支T 形梁h=1.35m,翼板f b '=1.7m ,C30混凝土,HRB335钢筋。I 类环境条件,安全等级为二级。跨中2/,l d M =1620kN ⋅m 求:配筋(焊接钢筋骨架)计算及截面复核 解: ○1计算参数cd f =13.8MPa td f =1.39MPa sd f =280MPa b ξ=0.56 0γ=1.0 M=0γ2/,l d M =1620kN ⋅m ○ 2截面换算,为了计算方便,将图1-1的实际T 形截面换算成图1-2所示的计算截面:f h '=2 100150+=125mm

结构设计计算书

湖南理工学院 南湖学院 题目:岳阳市某单位综合楼 作者:学号: 系别:土木建筑工程系专业:土木工程指导老师:职称:讲师 完成时间:

某理工学院办公楼设计 摘要:本设计的题目为岳阳市某单位综合楼。其中该设计分为建筑设计、结构设计和施工组织设计。 第一部分:建筑设计,本工程的建筑设计方案简单,采用对称布置,呈矩形。能充分满足了单位办公的需求,建筑立面造型独特,表现了学院办公楼建筑的特点。 第二部分:结构设计,本工程的结构设计围绕安全、经济两个重点展开,采用多层框架结构。其中选取一榀框架对其梁和柱的计算采用电算加手算,整个计算过程力求正确,基础采用柱下独立基础,并进行了楼梯和楼板的设计计算,过程详见计算书。 第三部分:施工组织设计,本工程施工组织设计详细阐述了施工布置、施工准备、施工方法、质量控制、安全生产等五个方面,明确了工程人员职则。并根据劳动定额及计算工程量确定日工作人数,绘制施工进度计划表。 关键词:办公楼建筑设计结构设计施工组织设计框架结构计算 Institute technonogy office building of the Design Summary: The topic originally designed is the office building of institute of some job. The designs hadbeen divided into the architectural design, design and operatiol of the structure and organize the design. First part : Architectural design, the architectural design of this project is simple ,adopt and fix up asymmetrically, take the form of rectangle word. Can fully meet the demand that the institute handles official business, the elevation model of the buikding is unique; have displayed the characteristic of the building of office building of the institute. Second part: Structural design, project this structural design launch around security , economy two focal points, adopt the multi-layer frame structure. Choose one pin frame adopt electricity is it add to roof beam and calculation of post their hand charge to regard as among them, the whole computational process strives to be correct, the foundation adopts the independent foundation under the post, the design carrying on the stair floor is calculated, the course sees and calculates the book. The third part : Construct and organize and design, this construction organizes the design to explain and construct such five respects as assigning , preparation of construction , construction method , quality control , safety in production ,etc. in detail , have defined project duties of personnel . And confirm the working number of people on day according to the work norm and project amount of calculation, draw the planning chart of the construction speed. Keyword: Office building Architectural design Structural design Construct and organize and design the frame structure calculating 目录