计算活度系数的UNIFAC基团贡献法(Ⅱ)

计算活度系数的UNIFAC基团贡献法(Ⅱ)
计算活度系数的UNIFAC基团贡献法(Ⅱ)

三元物系活度系数计算公式

三元物系活度系数计算公式 一、威尔逊公式 1、适用:互溶物系,特别是适用于极性和非极性混合物的活度系数计算 2、关系式 ①???? ??A ++A -+A +A ++A +=323221121 1332121 12213321211)ln(ln x x A x A x x x x A x x x γ ??? ? ??++-+++332231131 1331221133x A x A x A A x A x x A x ②???? ??A ++A -++A +++=313122112 233221 121123322112)ln(ln x A x x A x x A x x A x x A x γ ??? ? ??++-+++332231132 2332211233x A x A x A A x x A x A x ③???? ??A ++A -++A +++=313122113 332231 131133223113)ln(ln x A x x x A x A x x x A x A x γ ??? ? ??++-+++23 3221123 3322311322A x x A x A x A x A x A x 其中:?? ? ??Λ-= RT V V A L L 122 112exp ?? ? ??Λ-= RT V V A L L 211 221exp

??? ??Λ-= RT V V A L L 133 1 13exp ?? ? ??Λ-= RT V V A L L 311 331exp ? ? ? ??Λ-= RT V V A L L 233 223exp ?? ? ??Λ-= RT V V A L L 322 3 32exp --L i V 物系液相摩尔体积,kmol m /3 ; --R 热力学常数,8.314; --T 热力学温度,K ; --Λ威尔逊参数,λλ-=Λ12 λλ-=Λ21 12A 、--21A 端值常数 二、NRTL 公式 1、适用:液液部分互溶物系; 2、一般式 ∑ ∑∑∑∑∑======????? ? ?? ???? ?????? ? ?-+ = C j C k k kj C k kj kj k ij C k k kj ij j C k k ki C j j ji ji i x G G x x G G x x G x G 1 111 1 1ln τττ γ ) exp(ji ji ji a G τ-= RT g g jj ij ij /)(-=τ

(完整版)流量系数的计算

1 流量系数KV的来历 调节阀同孔板一样,是一个局部阻力元件。前者,由于节流面积可以由阀芯的移动来改变,因此是一个可变的节流元件;后者只不过孔径不能改变而已。可是,我们把调节阀模拟成孔板节流形式,见图2-1。对不可压流体,代入伯努利方程为: (1) 解出 命图2-1 调节阀节流模拟 再根据连续方程Q= AV,与上面公式连解可得: (2) 这就是调节阀的流量方程,推导中代号及单位为: V1 、V2 ——节流前后速度; V ——平均流速; P1 、P2 ——节流前后压力,100KPa; A ——节流面积,cm; Q ——流量,cm/S; ξ——阻力系数; r ——重度,Kgf/cm; g ——加速度,g = 981cm/s; 如果将上述Q、P1、P2 、r采用工程单位,即:Q ——m3/ h;P1 、P2 ——100KPa;r——gf/cm3。于是公式(2)变为: (3) 再令流量Q的系数为Kv,即:Kv = 或(4)这就是流量系数Kv的来历。

从流量系数Kv的来历及含义中,我们可以推论出: (1)Kv值有两个表达式:Kv = 和 (2)用Kv公式可求阀的阻力系数ξ = (5.04A/Kv)×(5.04A/Kv); (3),可见阀阻力越大Kv值越小; (4);所以,口径越大Kv越大。 2 流量系数定义 在前面不可压流体的流量方程(3)中,令流量Q的系数为Kv,故Kv 称流量系数;另一方面,从公式(4)中知道:Kv∝Q ,即Kv 的大小反映调节阀流量Q 的大小。流量系数Kv国内习惯称为流通能力,现新国际已改称为流量系数。 2.1 流量系数定义 对不可压流体,Kv是Q、△P的函数。不同△P、r时Kv值不同。为反映不同调节阀结构,不同口径流量系数的大小,需要跟调节阀统一一个试验条件,在相同试验条件下,Kv的大小就反映了该调节阀的流量系数的大小。于是调节阀流量系数Kv的定义为:当 调节阀全开,阀两端压差△P为100KPa,流体重度r为lgf/cm(即常温水)时,每小时 流经调节阀的流量数(因为此时),以m/h 或t/h计。例如:有一台Kv =50的调节阀,则表示当阀两端压差为100KPa时,每小时的水量是50m/h。 Kv=0.1,阀两端压差为167-(-83)=2.50,气体重度约为1 .0×E(-6),每小时流量大约为158 m/h。=43L/s=4.3/0.1s Kv=0.1,阀两端压差为1.67,气体重度约为1 2.2 Kv与Cv值的换算 国外,流量系数常以Cv表示,其定义的条件与国内不同。Cv的定义为:当调节阀全开,阀两端压差△P为1磅/英寸2,介质为60°F清水时每分钟流经调节阀的流量数,以加仑/分计。 由于Kv与Cv定义不同,试验所测得的数值不同,它们之间的换算关系:Cv = 1.167Kv (5)

近年电解质溶液活度的计算方法

近20年电解质溶液活度的计算方法 近20年电解质溶液活度的计算方法【摘要】讨论了近20年电解质溶液活度的计算方法。凡是涉及到溶液中的反应,以及和溶液有关的性质,都直接地和溶液的浓度有关,而对电解质溶液,于和理想溶液有偏差,所以在讨论电解质时,就不能用浓度这一慨念,而要活度,对于活度,关键在于对活度系数的计算。最近20年内对于电解质活度的计算方法有众多,但他们大多数都是建立在实验的基础之上,而的主要内容也是建立在前人的实验基础之上,其中包括非缔合式和缔合式电解质溶液活度系数的测定方法,平均球近似计算电解质活度系数和理想电解质溶液活度的计算。【关键词】电解质溶液、测定、理想溶液、活度、计算方法The ways to calculate electrolytic solution in recent 20

years Digest:This article discusses about the ways to calculate electrolytic solution in recent 20 years. All the reactions and solution properties which are related to solution have something to do with the concentration of solution directly. However, in terms of electrolytic solution, there is a deviation with the ideal one, so we measure it by activity in stead of concentration. While, on the part of activity, it is crucial to calculate its coefficient. There are plenty of measures to compute the activity of electrolytic solution, and most of them are on the basis of experiments, so is the case with this thesis. While it contains associate, nonassociated ,average and ideal measuring methods of the activity of electrolytic solution. Key words:Electrolytic solution、Measuring、Ideal solution、Activity、Computing methods 电解质的定义概念:在水溶液里

Pitzer活度系数模型研究与开发

龙源期刊网 https://www.360docs.net/doc/f818376840.html, Pitzer活度系数模型研究与开发 作者:韩莎莎郑俊强孙晓岩项曙光 来源:《当代化工》2020年第01期 Research and Development of Pitzer Activity Coefficient Model HAN;Sha-sha,ZHENG;Jun-qiang,SUN;Xiao-yan,XIANG;Shu-guang (Process Systems Engineering Institute, Qingdao University of Science and Technology,Shandong Qingdao 266042, China) 自然界、生命体和工业过程中普遍存在着电解质溶液,是化工行业中的重要组成部分,也是众多过程处理的对象,目前逐渐成为许多有机物和無机物反应的良好媒介,因此对电解质溶液的理论研究、电解质溶液的热力学性质的研究及电解质过程模拟研究具有重要的工业实用价值和理论意义。 其中在电解质溶液理论及含电解质溶液体系的热力学性质方面,Debye[1]、Meissner[2]、Bromley[3]、Chen[4]、陆小华[5]、左有祥[6,7]、Loehe[8]、李以圭[9]和杜艳萍[10]等都做出了很大的贡献。目前Pitzer是用于计算水电解质溶液体系(尤其是离子强度为6摩尔以下的强电解质体系)的活度系数等热力学性质较为准确的电解质活度系数模型,也是应用最为广泛的电解质溶液理论。最初1973年,Pitzer修正了D-H理论[1],得到了经典的半经验Pitzer模型[11],但适用的浓度较低。随后为了扩大浓度适用范围,用Margules方程修正了短程项,得到了Pitzer[12](1980年)模型。之后,Bromley[3](1973年)简化的Pitzer模型、Pitzer[13](1975年)添加的静电非对称混合项、Fürst和Renon[14](1982年)研究的多种参数对模型用于1-1型电解质固 液平衡的影响、李以圭[15,16](1986年)的Pitzer-Li方程、Simonson等[17](1986年)的Pitzer-Simonson方程、Kim等[18,19](1988年)回归的高浓度体系参数、Clegg等[20,21](1992年)的Clegg-Pitzer模型、李以圭等[22,23](1994和1997年)的Li-Mather模型、Pitzer[24](1999年)以及Chen等[25](2008年)都对Pitzer模型做了相应的修正和完善。因此,参照Fortran语言编程如Zemaitis[26]中实现含电解质体系的模拟计算过程,也可通过Visual C++编程语言开发Pitzer模型,实现被已有的支持CAPE-OPEN标准的大型通用化工模拟软件所调用,从而对工业中含电解质溶液过程进行设计、模拟、计算和优化,更好地解决较复杂的工程问题。 本文主要是根据Pitzer修正的水电解质溶液体系活度系数计算模型[13](1975年模型)进行开发并通过对一些应用实例的模拟计算并验证结果对该开发的Pitzer活度系数模型进行分析、讨论和评价。 1 ;Pitzer活度系数模型

近20年电解质溶液活度的计算方法

近20年电解质溶液活度的计算方法 【摘要】本文讨论了近20年电解质溶液活度的计算方法。凡是涉及到溶液中的反应,以及和溶液有关的性质,都直接地和溶液的浓度有关,而对电解质溶液,由于和理想溶液有偏差,所以在讨论电解质时,就不能用浓度这一慨念,而要活度,对于活度,关键在于对活度系数的计算。最近20年内对于电解质活度的计算方法有众多,但他们大多数都是建立在实验的基础之上,而本文的主要内容也是建立在前人的实验基础之上,其中包括非缔合式和缔合式电解质溶液活度系数的测定方法,平均球近似计算电解质活度系数和理想电解质溶液活度的计算。 【关键词】电解质溶液、测定、理想溶液、活度、计算方法 The ways to calculate electrolytic solution in recent 20 years Digest: This article discusses about the ways to calculate electrolytic solution in recent 20 years. All the reactions and solution properties which are related to solution have something to do with the concentration of solution directly. However, in terms of electrolytic solution, there is a deviation with the ideal one, so we measure it by activity in stead of concentration. While, on the part of activity, it is crucial to calculate its coefficient. There are plenty of measures to compute the activity of electrolytic solution, and most of them are on the basis of experiments, so is the case with this thesis. While it contains associate, nonassociated ,average and ideal measuring methods of the activity of electrolytic solution. Key words: Electrolytic solution、Measuring、Ideal solution、Activity、Computing methods

液相活度系数方程总结

液相活度系数方程总结 1、Wohl 模型 Wohl 模型是一个普通模型,可以概括Margules 方程(1895年)、Van Laar 方程(1910年)以及Scatchard-Hamer 方程(1953年)。 Whol 在1946年提出将超额自由焓E G 表示为有效容积分率的函数,并展开成为Mc Laurin 级数: +++=∑∑∑∑∑∑∑∑∑∑i j k l ijkl l k j i i j k ijk k j i i j ij j i i i i E a Z Z Z Z a Z Z Z a Z Z x q RT G (1-1) 式中:i Z ——混合物中i 组分的有效容积分率:1=? = ∑∑i i i i i i i i Z x q x q Z ; i x ——i 组分的摩尔分数; i q ——i 组分的有效摩尔体积; ij a ——i-j 两组分之间的交互作用参数,称为二尾标交互作用参数; ijk a ——i-j-k 三组分之间的交互作用参数,称为三尾标交互作用参数; ijkl a ——i-j-k-l 四组分之间的交互作用参数,称为四尾标交互作用参数; 略去四分子以上集团相互作用项,将式(1-1)用于二元系统时变为: () 1222 2111222112212211332a Z Z a Z Z a Z Z x q x q RT G E ++=+ (1-2) 令: ()12212132a a q A += ()11212232a a q B += 代入上式,根据() j n p T i E i n RT nG ,,ln ? ?? ?????=γ将式(1-2)对i n 进行偏微分,经整理得: ??? ?? ????? ??-+=A q q B Z A Z 2112 2 12ln γ (1-3a ) ??? ?? ????? ??-+=B q q A Z B Z 1222122ln γ (1-3b ) 式(1-3)中包括三个参数A 、B 与12q q ,其值必须用实验值来确定。 2、Scatchard-Hamer eq . 用纯组分的摩尔体积l V 1及l V 2代替有效摩尔体积1q 及2q ,则式(1-3a )和式(1-3b )就变为:

活度系数计算

电解质溶液活度计算理论进展 【摘要】:由于溶液大多数不是理想溶液,需要用活度来代替浓度。活度系数 又是描述活度与浓度的差异程度,因此活度系数的计算对于反应过程相当的重要。近几年,随着活度系数理论模型的不断发展,活度系数的计算方法也在不断的提高、创新。本文在回顾电解质溶液热力学经典理论的基础上,对活度系数计算做了综述。 【关键词】:活度系数活度模型热力学模型活度计算 Electrolyte solution activity in recent years, progress in computational theory Abstract:Solution is not ideal because most of the solution need to replace the concentration of activity. Activity coefficient is described differences in degree of activity and concentration, so the calculation of activity coefficients for the reaction process was very important. In recent years, with the activity coefficient of the continuous development of theoretical models, the calculation of activity coefficients are also constantly improving and innovation. In this paper, recalling the classical theory of thermodynamics of electrolyte solution, based on calculations made on the activity coefficient is reviewed. Keywords: Activity coefficient, Activity Model, Thermodynamic model, Activity calculation 1、活度与活度系数 绝大多数的反应都有溶液(固溶体、冶金熔体及水溶液)参加,而这些溶液经常都不是理想溶液,在进行定量的热力学计算和分析,溶液中各组分的浓度必须代以活度。活度的概念首先由刘易斯(G.N.Lewis)于1907年提出,迅速被应用于电化学,以测定水溶液中电解质的活度系数。活度不能解决冶金熔体的结构问题。它能指出组分在真实溶液与理想溶液中热力学作用上的偏差,但不能提供造成偏差的原因。

特性系数计算方法

选定系统中最不利工作作用面积,如(图3-4-1)选择最不利管径标号如图。 (1) 计算最不利喷头(喷头0)的喷水量: 使用公式为: H K q 10= (3-38) q ——计算喷头喷水量,(L/min ) K —— 喷头流量系数,标准喷头K=80; H ——喷头工作压力,MPa ; s L L q /94.0min /4.5605.010800==??= (2) 管道沿程和局部损失: 设计流速:钢管流速一般不大于5m/s,配水干管一般不超过3m/s ,常用1~2m/s 。校核流速之按照下列公式就算: Q K v c = (3-39) 式中 v ——流速 (m/s ) c K ——计算管段流速系数 (m/s ),可查表; Q ——计算管段流量 (L/s ) 表3-15 流速系数表 (3)管道沿程水头损失按照下列公式计算: 2 A L Q h = (3-40) 式中 h ——沿程水头损失,(O mH 2) A ——管道比阻,可查表; L ——计算管段长度,(m ) Q ——计算管段流量,(L/s )

(4)计算1~0的扬程水头损失 管段1~0的管径使用DN25,流速为 s m Q K v c /79.195.0883.11=?== 点“1”到点0的水头损失为: m P a O mH ALQ h 0168.0678.1033 .1)6.03(4367.022 0~~12 ==?+?== (5)计算喷头1的出水量: 喷头1的工作压力为: m P a h H H 074.0014.006.00~~101=+=+= 1号喷头喷水量为: s L L H K q /07.1min /2.64074.010801011==??=?= 依次类推到喷头4 的节点(喷头)流量。 (6)特性系数的推导 图3-10 特性系数计算草 使用沿程损失公式计算: 452 4~54~54~54~5H H Q L A h -=?= (1) e e e e e H H Q L A h -=?=62~6~6~6~6 (2) 用(1)/(2)得: 4 5e 62 4 ~52~6H H H H Q Q e --= 4 5e 64 ~5~6H H H H Q Q e --=

相关系数计算公式

相关系数计算公式 相关系数计算公式 Statistical correlation coefficient Due to the statistical correlation coefficient used more frequently, so here is the use of a few articles introduce these coefficients. The correlation coefficient: a study of two things (in the data we call the degree of correlation between the variables). If there are two variables: X, Y, correlation coefficient obtained by the meaning can be understood as follows: (1), when the correlation coefficient is 0, X and Y two variable relationship. (2), when the value of X increases (decreases), Y value increases (decreases), the two variables are positive correlation, correlation coefficient between 0 and 1. (3), when the value of X increases (decreases), the value of Y decreases (increases), two variables are negatively correlated, the correlation coefficient between -1.00 and 0. The absolute value of the correlation coefficient is bigger, stronger correlations, the correlation coefficient is close to 1 or -1, the higher degree of correlation, the correlation coefficient is close to 0 and the correlation is weak. The related strength normally through the following range of judgment variables: The correlation coefficient 0.8-1.0 strong correlation 0.6-0.8 strong correlation

煤矿井下供电常用计算公式和系数

煤矿供电计算公式 井 下 供 电 系 统 设 计 常 用 公 式 及 系 数 取 值

目录: 一、短路电流计算公式 1、两相短路电流值计算公式 2、三相短路电流值计算公式 3、移动变电站二次出口端短路电流计算 (1)计算公式 (2)计算时要列出的数据 4、电缆远点短路计算 (1)低压电缆的短路计算公式 (2)计算时要有计算出的数据 二、各类设备电流及整定计算 1、动力变压器低压侧发生两相短路,高压保护装值电流整定值 2、对于电子高压综合保护器,按电流互感器二次额定电流(5A)的1-9倍分级整定的计算公式 3、照明、信号、煤电钻综合保护装置中电流计算 (1)照明综保计算公式 (2)煤电钻综保计算公式 4、电动机的电流计算 (1)电动机额定电流计算公式 (2)电动机启动电流计算公式 (3)电动机启动短路电流 三、保护装置计算公式及效验公式 1、电磁式过流继电器整定效验 (1)、保护干线电缆的装置的计算公式 (2)、保护电缆支线的装置的计算公式 (3)、两相短路电流值效验公式 2、电子保护器的电流整定 (1)、电磁启动器中电子保护器的过流整定值 (2)、两相短路值效验公式 3、熔断器熔体额定电流选择 (1)、对保护电缆干线的装置公式 (2)、选用熔体效验公式 (3)、对保护电缆支线的计算公式 四、其它常用计算公式 1、对称三相交流电路中功率计算 (1)有功功率计算公式 (2)无功功率计算公式 (3)视在功率计算公式 (4)功率因数计算公式

2、导体电阻的计算公式及取值 3、变压器电阻电抗计算公式 4、根据三相短路容量计算的系统电抗值 五、设备、电缆选择及效验公式 1、高压电缆的选择 (1) 按持续应许电流选择截面公式 (2) 按经济电流密度选择截面公式 (3) 按电缆短路时的热稳定(热效应)选择截面 ①热稳定系数法 ②电缆的允许短路电流法(一般采用常采用此法) A、选取基准容量 B、计算电抗标什么值 C、计算电抗标什么值 D、计算短路电流 E、按热效应效验电缆截面 (4) 按电压损失选择截面 ①计算法 ②查表法 (5)高压电缆的选择 2、低压电缆的选择 (1)按持续应许电流选择电缆截面 ①计算公式 ②向2台或3台以上的设备供电的电缆,应用需用系数法计算 ③干线电缆中所通过的电流计算 (2)按电压损失效验电缆截面 ①干线电缆的电压损失 ②支线电缆的电压损失 ③变压器的电压损失 (3) 按起动条件校验截面电缆 (4) 电缆长度的确定 3、电器设备选择 (1)变压器容量的选择 (2)高压配电设备参数选择 ①、按工作电压选择 ②、按工作电流选择 ③、按短路条件校验 ④、按动稳定校验 (3)低压电气设备选择

活度计算

最近二十年内电解质溶液活度计算理论 摘要:纵观所有的化学反应过程,大多数的反应都是在水溶液中进行的。因此, 溶液中活度的计算占据着重要的作用,本文介绍了最近二十年的电解质溶液计算的理论及其进展。 关键字:二十年内,电解质溶液,活度计算,理论 In the recent twenty years activity calculation in electrolyte solution theory Wu hui Abstract : . Throughout all of the chemical reaction process, most of the reactions are performed in aqueous solution. Therefore, in the solution the calculation of activity plays an important role in the recent twenty years, this paper introduces the calculating theory and its progress in electrolyte solution Key word : In twenty years, electrolyte solution, calculation of activity, theory 引言: 电解质溶液广泛存在于自然界中,同时也是绝大多数过程处理的对象,现在电解质溶液越来越成为许多无机反应和有机反应的良好媒介。在化工、生物、冶金、地质、海洋及环保等领域中得以广泛应用。因而,电解质溶液及其相关理论不断得到发展及进步,其中活度计算取得了一定的进展并产生了一些新的理论模型,本文将作一些简要和初步的介绍。 1.以Pitzer 电解质溶液理论为基础的二个改进型方程 电解质溶液热力学经典理论的适用范围是十分有限的,特别是对于温差变化大或浓度较大的溶液来说,计算值与实验值的差别较大。20世纪70年代统计力学理论得到了迅速的发展,以Pitzer 方程为代表的电解质溶液理论逐渐占据了主导地位。Pitzer 从电解质水溶液的径向分布函数出发,提出了溶液的总过量自由能表达式,再导出了渗透系数与活度系数的计算公式。近十年来,以Pitzcr 电解质溶液理论为基础的改进型方程的提出,使得在较宽的浓度范围内溶液活度系数和溶液总自由能的计算结果和实验值符合得较好,该理论目前已成为世界上普遍承认的较为成熟的电解质溶液理论。 1.1 Pitzcr 电解质溶液理论基础 Pitzer 在1973午提出了计算电解质溶液渗透系数和溶液活度系数的方程[1,2] 渗透系数的表达式如下: φαν ννβ β ν ννφφMX X M I MX MX X M X M C m e m bI I A Z Z 2 3 2 )1()0(2 1 21 ) 2()(2112 1 ++++-=-- 由实验数据拟合的结果得到参数b 和α的具体数值。Pitzer 等已将25℃时二 百八十多种电解质水溶液的渗透系数数据进行了回归,得到了各个与β有关的数

活度系数实验报告

实验三 色谱法测定无限稀释溶液的活度系数 一、实验目的 1. 用气液色谱法测定苯和环己烷在邻苯二甲酸二壬酯中的无限稀释活度系数。 2. 通过实验掌握测定原理和操作方法。熟悉流量、温度和压力等基本测量方法。 3. 了解气液色谱仪的基本构造及原理。 二、基本原理 采用气液色谱测定无限稀释溶液活度系数,样品用量少,测定速度快,仅将一般色 谱仪稍加改装,即可使用。目前,这一方法已从只能测定易挥发溶质在难挥发溶剂中的 无限稀释活度系数,扩展到可以测定在挥发性溶剂中的无限稀释活度系数。因此,该法 在溶液热力学性质研究、气液平衡数据的推算、萃取精馏溶剂评选和气体溶解度测定等 方面的应用,日益显示其重要作用。 当气液色谱为线性分配等温线、气相为理想气体、载体对溶质的吸附作用可忽略等 简化条件下,根据气体色谱分离原理和气液平衡关系,可推导出溶质i 在固定液j 上进 行色谱分离时,溶质的校正保留体积与溶质在固定液中无限稀释活度系数之间的关系式。 根据溶质的保留时间和固定液的质量,计算出保留体积,就可得到溶质在固定液中的无 限稀释活度系数。 实验所用的色谱柱固定液为邻苯二甲酸二壬酯。样品苯和环己烷进样后汽化,并与 载气2H 混合后成为气相。 当载气2H 将某一气体组分带过色 谱柱时,由于气体组分与固定液的相互 作用,经过一定时间而流出色谱柱。通 常进样浓度很小,在吸附等温线的线性 范围内,流出曲线呈正态分布,如右图 所示。 设样品的保留时间为r t (从进样到样品峰顶的时间),死时间为d t (从惰性气体空气 进样到其峰顶的时间),则校正保留时间为: d r r t t t -=' (1)

共毒系数计算公式以及举例

共毒系数计算公式以及举例 (专业植物保护知识) 毒力评判采用孙云沛法,计算共毒系数(co-toxicity coefficient,CTC),以CTC 值评判两种药剂的联合毒力作用。CTC 值小于80为拮抗作用,大于120为增效作用,80-120之间时为相加作用。 实际毒力指数 × 100% 毒力指数× 100% 理论毒力指数 TTI = 标准药剂毒力指数 × 标准药剂在混合组配中所占百分比 + 供试药剂毒力指数 × 供试药剂在混合组配中所占百分比 共毒系数× 100% 应用举例 例如螺螨酯与马拉硫磷 4:3混配, 螺螨酯LC50=80 马拉硫磷LC50=100 4:3混配LC50=60 设螺螨酯为标准药剂,则 螺螨酯TI = 螺螨酯LC50/螺螨酯LC50 *100 =100 马拉硫磷TI = 螺螨酯LC50/马拉硫磷LC50 * 100 = 100/80 *100 = 125 4:3混配ATI = 螺螨酯LC50/4:3混配LC50 * 100 = 80/60 *100 = 133.33

4:3混配TIT = 标准药剂毒力指数×标准药剂在混合组配中所占百分比 + 供试药剂毒力指数×供试药剂在混合组配中所占百分比 = 螺螨酯TI * 4/7 + 马拉硫磷TI * 3/7 = 100 * 4/7 + 125 * 3/7 = 57.1429 + 53.5714 = 110.7143 4:3混配共毒系数 CTC = 4:3混配ATI/4:3混配TIT *100 = 133.33/110.7143 *100 = 120.4271 再用CTC判断增效、相加和拮抗。 2012-10-11 注:文档质量没问题,请让我上传,我自己写的,文库管理员。。。。2012-10-11 8:06:54

计算公式含量

一滴定: 计算公式: V×T×C r 含量相当于标示量(%)= ×100% W×C s ×规格×1000 V:供试品消耗滴定液体积(ml); T:滴定液按照被测物质表示的滴定度; W:样品体积(ml)或重量; C r :滴定液的实际浓度; C s :滴定液的标准浓度。 二液相: 计算公式:(外标法) A S ×f×d Wr×P 含量相当于标示量(%)= ×100% f= C S ×规格 A r A S :供试品溶液的吸收度(峰面积); W r :对照品(标准)的取样量(g); C S :供试品溶液的浓度; A r :对照品(标准)的吸收度; d:对照品(标准)溶液的浓度。 P:对照品的含量% (内标法) A S ×f×d Wr×P×As1 含量相当于标示量(%)= ×100% f= C S ×规格 A r ×As2 As1:对照品中内标物的吸收度 As2 :样品中内标物的吸收度 A S :供试品溶液的吸收度; W r :对照品(标准)的取样量(g); C S :供试品溶液的浓度; A r :对照品(标准)的吸收度; d:对照品(标准)溶液的浓度。 P:对照品的含量%三紫外 计算公式:(对照法) A S ×f×d W r ×P 含量相当于标示量(%)= ×100% f= C S ×规格 A r A S :供试品溶液的吸收度; Wr:对照品(标准)的取样量(g); C S :供试品溶液的浓度; A r :对照品(标准)的吸收度; d:对照品(标准)溶液的浓度。 P:对照品的含量% (吸收系数法) A S 含量相当于标示量(%)=-------------------×100% C S ×规格×E×100 A S :供试品溶液的吸收度;C S :供试品溶液的浓度; E:吸收系数

浓度计算方法

(1)体积比例浓度: 例:配制(1+2)H2SO4150(毫升) 解:假如所取浓H2SO4为x毫升,则加入水应为2x毫升 x+2x=150(毫升)x=50(毫升) 加水的体积为150-50=100(毫升) 取50毫升浓H2SO4徐徐加入到100毫升水中并不断搅拌,即配成1:2的H2SO4溶液。(2)重量百分比浓度的配制: 溶质是固体: 例:配制20%的KOH溶液200克 解:溶质量=溶液重×重百分比浓度 所以KOH重量=200×20%=40(克) 溶剂水重=200-40=160(克) 称取40克KOH溶于160毫升水中摇匀即可配制成20%的KOH溶液。 溶质是液体: 例:配制1%HCl溶液500克 解:已知浓HCl,C=36%,Cl=1.19 需浓HCl x克则水的体积为500-x÷1.19 x=1%×500÷36%=13.9(克) 需浓HCl的毫升数=13.9÷1.19=11.68≈12(毫升),水的体积为500-12=488(毫升) 量取12毫升HCl倒入488毫升水中摇匀即可。 两种百分比浓度溶液混合: 例:用85%的H2SO4和40%的H2SO4配制60%的H2SO41000毫升,各需多少毫升H2SO4溶液。

解:设需用85%H2SO4V1毫升,40%H2SO4V2=(1000-V1)毫升 则V3=V1+V2=1000(毫升) C1=85%C2=40%C3=60% d1=1.78 d2=1.30 d3=1.50 C1d1V1+C2d2V2=C3d3V3 85%×1.78×V1+40%×1.30×(1000-V1)=60%×1.50×1000 1.51V1+0.52 V1=900-520 V1≈383(毫升)V2=1000-383=617(毫升) 量取85%的H2SO4溶液383毫升与40%的H2SO4溶液617毫升混合即得60%的H2SO41000毫升。 (3)体积百分浓度的配制 例:配制20%的KOH溶液1000毫升 解:KOH的质量=1000×20%=200(克) 称取200克KOH溶于1000毫升水中即可。 (4)摩尔浓度的配制 例:配制0.015M的EDTA溶液2000毫升 解:已知EDTA分子量=372.26 称取EDTA质量=372.26×0.015×2=11.17(克) 称取11.17克EDTA溶于2000毫升水中即可。 (5)当量浓度的配制: 例:配制0.25N的NaOH溶液2000毫升 解:NaOH分子量=40

第三章附录相关系数r 的计算公式的推导

相关系数r AB 的计算公式的推导 设A i 、B i 分别表示证券A 、证券B 历史上各年获得的收益率;A 、B 分别表示证券A 、证券B 各年获得的收益率的平均数;P i 表示证券A 和证券B 构成的投资组合各年获得的收益率,其他符号的含义同上。 2 A σ=11 -n 2)(∑-A A i 2B σ=11-n )(B B i -∑2 2 P σ=11-n 2)1(∑∑-i i P n P =2)](1 )[(11i B i A i B i A B A A A n B A A A n +-+-∑∑ =2)]()[(11 B A A A B A A A n B A i B i A +-+-∑ =2)]()([11 B B A A A A n i B i A -+--∑ =)])((2)()([1 122 22B B A A A A B B A A A A n i i B A i B i A --+-+--∑ =A 2A × 22 1 ) (B i A n A A +--∑× 1 )] )([(21 )(2 ---+ --∑∑n B B A A A A n B B i i B A i =A 1 )] )([(22222 ---? ++∑n B B A A A A A i i B A B B A A σσ 对照公式(1)得: = 1 )(2 --∑n A A i × 1 )(2 --∑n B B i × r AB ∴ r AB = ∑∑∑-?---2 2 ) ()()] )([(B B A A B B A A i i i i 这就是相关系数r AB 的计算公式。 投资组合风险分散化效应的内在特征 1.两种证券构成的投资组合为最小方差组合(即风险最小)时各证券投资比例的测定 公式(1)左右两端对A A 求一阶导数,并注意到A B =1—A A : (2 P σ)′=2 A A 2A σ-2 (1-A A )2 B σ+2 (1-A A )B A σσ r AB -2A A B A σσ r AB 令 (2P σ)′= 0 并简化,得到使2 P σ取极小值的A A : AB B A i i r n B B A A σσ =---∑1 )])([(

酸碱计算公式

从白蛋白水平推算血清钙浓度的矫正值 血清钙浓度矫正值(mg/dl)=钙测定值(mg/dl)+[×(4-白蛋白(g/dl))] 从葡萄糖推算血清钠浓度的矫正值 血清钠浓度矫正值(mEq/L)=钠测定值(mg/dl)+[×((葡萄糖(mEq/L)-150)/100)] 代谢性酸中毒时的补碱量 1.公式一 HCO3需要量(mmol)=[ HCO3正常值(mmol)-HCO3测得值(mmol)]×体重(kg)× 2.公式二 A、〔正常CO2结合力(50%)-测得之CO2结合力〕××体重(kg)=mL(5%碳酸氢钠) B、〔正常CO2结合力(50%)-测得之CO2结合力〕××体重(kg)=mL(%乳酸钠) C、〔正常CO2结合力(50%)-测得之CO2结合力〕××体重(kg)=mM(THAM) 注:THAM系三羧甲基氨基甲烷,%溶液,含THAM1mmol 低渗及等渗性脱水的补液量计算 1.按体重减轻估计补液量 生理盐水补液量(L)=正常血钠浓度(142mmol/L)×体重减轻量(kg)/每升生理盐水NaCL 含量(154mmol) 2.按血细胞压积估计补液量 补液量(L)=[实际红细胞压积-正常红细胞压积×体重(kg)×]/正常红细胞压积。 正常红细胞压积男性为48%,女性42%。 细胞外液量为体重×。 3.按血清钠估计补液量 补液量(L)=体重(kg)×0.2×(正常血钠浓度-实际血钠浓度)/每升生理盐水NaCL含量(154mmol) 4.依据血钠浓度计算低渗性失水的补钠量 补钠量=[血钠正常值(mmol/L)-实际血钠浓度(mmol/L)]××体重(kg)(女性为) 失水量(按血细胞比容计算) 失水量(ml)=(目前血细胞比容-原来血细胞比容)÷原来血细胞比容×体重(kg)××1 000 原来血细胞比容如不知道,可用正常值代替,男性和女性分别为和,式中20%为细胞外液占体重的比例。 急性低钠血症Na+需要量

实验二气相色谱法测定无限稀释活度系数(精)

实验二 气相色谱法测定无限稀释活度系数 用经典方法测定汽液平衡数据需消耗较多人力、物力。如果有无限稀释活度系数,则可确定活度系数关联式中的常数,进而可推算出全组成范围内的活度系数。采用气相色谱法测定无限稀释溶液活度系数样品用量少,测定速度快,将一般色谱仪稍加改装即可使用。这一方法不仅能测定易挥发溶质在难挥发溶剂中的无限稀释活度系数,而且已扩展到测定挥发性溶剂中的无限稀释活度系数。 一.实验目的 1.用气相色谱法测定苯和环己烷在邻苯二甲酸二壬酯中的无限稀释活度系数; 2.通过实验掌握测定原理和操作方法。 二.实验原理 1.活度系数计算公式 液相活度系数可以用Wilson 方程来计算,对于二元体系: ln γ1=-ln(x 1+Λ12x 2)+x 2(212112x x Λ+Λ -1 21221x x Λ+Λ) (1) ln γ2=-ln(x 2+Λ21x 1)+x 1(212112x x Λ+Λ -1 21221x x Λ+Λ) (2) 对于无限稀释溶液,则有 )1(ln ln 21121Λ-+Λ-=∞γ (3) )1(ln ln 12212 -Λ+Λ-=∞γ (4) 式中:∞1ln γ——组分1的无限稀释活度系数 ∞2ln γ——组分2的无限稀释活度系数 通过实验测得了∞1ln γ、∞2ln γ,便可求得配偶参数Λ12、Λ21。 2.平衡方程 LittleWood 认为在气相色谱中,载体对溶质的作用不计,固定液与溶质之间有气液溶解平衡关系。 把气体(载气和少量溶质)看成是理想气体,又由于溶质的量很少(只有4-5微升),可以认为吸附平衡时,被吸附的溶质i 分子处于固定液的包围之中,所以有: L L i i i i i i N n r P x r P P ∞∞==00 (5)

相关文档