血氧饱和度监测技术操作规范

血氧饱和度监测技术操作规范

混合静脉血氧饱和度

混合静脉血氧饱和度 拉丁学名:Oxygen Saturation of Mixed Venose Blood;SvO2 相关疾病:循环衰竭;败血症;心源性休克;甲亢;贫血及变性血红蛋白症;脓毒症 【参考值】 68%~77%;平均75% 【临床意义】 通过测定混合静脉血氧饱和度(SvO2)来计算动静脉血氧含量差,能较准确反映心排出量。Waller等曾指出SvO2和心脏指数、每搏指数及左心室每搏指数之间有很高的相关性。SvO2下降,而动脉血氧饱和度和耗氧量尚属正常时,则可证明心排血量也是低的。因此现在认为混合静脉血的氧饱和度检查对严重心肺疾患的监测具有重要价值。 SvO2增高的常见原因是脓毒症,此外氰化物中毒及低温也可使SvO2增高。 SvO2降低的原因有:心输出量下降导致的血循环量不足、周围循环衰竭、败血症、心源性休克、甲亢、贫血及变性血红蛋白症、肺部疾患等各种原因导致的氧合功能减低者。SvO2低于60%时,通常提示组织耗氧增加或心肺功能不佳。 临床上连续测定SvO2对危重患者的监测起到重要作用,并对治疗方法及药物使用也有一定的指导作用 Nuclear factor kB (NF-kB) is a nuclear transcription factor that regulates expression of a large number of genes that are critical for the regulation of apoptosis, viral replication, tumorigenesis, inflammation, and various autoimmune diseases. The activation of NF-kB is thought to be part of a stress response as it is activated by a variety of stimuli that include growth factors, cytokines, lymphokines, UV, pharmacological agents, and stress. In its inactive form, NF-kB is sequestered in the cytoplasm, bound by members of the IkB family of inhibitor proteins, which include IkBa, IkBb, IkBg, and IkBe. The various stimuli that

脉搏血氧饱和度测量方法

如对您有帮助,可购买打赏,谢谢脉搏血氧饱和度测量方法 导语:脉搏的血氧饱和度,对于身体的健康是特别有益处的,脉搏的血氧如果出现了问题,就会对自己的身体构成严重的影响,所以很多出现这种疾病的患 脉搏的血氧饱和度,对于身体的健康是特别有益处的,脉搏的血氧如果出现了问题,就会对自己的身体构成严重的影响,所以很多出现这种疾病的患者,就想全面了解脉搏血氧饱和度测量方法,下面的内容就做了介绍,你可以全面地来了解一下。 血氧饱和度(SaO2)是血液中被氧结合的氧合血红蛋白(HbO2)的容量占全部可结合的血红蛋白(Hb,hemoglobin)容量的百分比,即血液中血氧的浓度,它是呼吸循环的重要生理参数。而功能性氧饱和度为HbO2浓度与HbO2+Hb浓度之比,有别于氧合血红蛋白所占百分数。因此,监测动脉血氧饱和度(SaO2)可以对肺的氧合和血红蛋白携氧能力进行估计。正常人体动脉血的血氧饱和度为98% ,静脉血为75%。在临床上目前可以用取动脉血测量其中的氧分压来计算SaO2(不能连续监测),也可以用脉搏血氧仪(PulseOximetr),使用光电技术,在不用取血的情况下连续测量动脉血中的血氧饱和度。 测量方法 许多临床疾病会造成氧供给的缺乏,这将直接影响细胞的正常新陈代谢,严重的还会威胁人的生命,所以动脉血氧浓度的实时监测在临床救护中非常重要。 传统的血氧饱和度测量方法是先进行人体采血,再利用血气分析仪进行电化学分析,测出血氧分压PO2计算出血氧饱和度。这种方法比较麻烦,且不能进行连续的监测。 目前的测量方法是采用指套式光电传感器,测量时,只需将传感器预防疾病常识分享,对您有帮助可购买打赏

血氧饱和度测量仪的设计要点

血氧饱和度测量仪 的设计

目录 摘要 (3) 第一章绪论 (4) 1.1血氧饱和度的基本概念 (4) 1.2血氧饱和度测量仪课程设计的意义 (3) 1.3血氧饱和度测量仪课程设计的技术要求 (4) 1.4基本步骤 (5) 1.4.1 理论依据 (5) 1.4.2 硬件电路的设计 (6) 1.4.3 软件设计 (6) 1.4.4 仿真及数值定标 (6) 第二章实验方案设计及论证 (6) 2.1 设计理论依据 (6) 2.2. 双波长法的概念 (6) 2.3 光电脉搏传感器 (7) 2.4 传感器可能受到的干扰 (9) 2.5实验方案设计 (10) 第三章硬件电路的设计 (10) 3.1硬件原理框图 (10) 3.2各部分电路的设计 (11) 第四章软件模块设计 (13) 4.1主程序流程图 (14) 4.2子程序流程图 (14) 4.3硬件调试 (16) 第五章设计收获及心得体会 (17) 第六章参考文献 (19) 附录程序清单 (20)

摘要 氧是维持人体组织细胞正常功能,生命活动的基础。人体的绝大多数组织细胞的能量装换均需要氧的参加。所以,实时监护人体组织中氧的代谢具有重要的意义。 人体的新陈代谢过程是生物氧化过程。氧通过呼吸系统进入人体血液,与血液红细胞中的血红蛋白(Hb)结合成氧合血红蛋白(2HbO ),再输送到人体各部分组织细胞中去。在全部血液中,被氧结合的2HbO 容量占全部可结合容量的百分比称为血氧饱和度2O Sa 。许多临床疾病会造成氧供给的缺乏,这将直接影响细胞的正常新陈代谢,严重的还会威胁人的生命,所以动脉血氧浓度即2O Sa 。 的实时监测在临床救护中非常重要。 在本次关于血氧饱和度测量仪的设计中,是基于MCS —51单片机的设计,需要选测合适的光电脉搏传感器采集数据,并利用4为LED 数码显示测量值,利用键盘切换显示脉搏跳动的频率。 关键词:51单片机 血氧饱和度 比尔—朗伯定理

中心静脉穿刺置管操作常规

中心静脉穿刺置管操作常规 适应症 监测中心静脉压(CVP); 快速补液、输血或给血管活性药物; 胃肠外营养; 插入肺动脉导管; 进行血液透析、滤过或血浆置换; 使用可导致周围静脉硬化的药物; 无法穿刺外周静脉以建立静脉通路; 特殊用途如心导管检查、安装心脏起搏器等; 禁忌证 出血倾向(禁忌行锁骨下静脉穿刺); 局部皮肤感染(选择其他深静脉穿刺部位); 胸廓畸形或有严重肺部疾患如肺气肿等,禁忌行锁骨下静脉穿刺; 术前准备 置管前应明确适应症,检查患者的出凝血功能。对清醒患者,应取得患者配合,并予适当镇静。准备好除颤器及有关的急救药品。 准备穿刺器具:包括消毒物品、深静脉穿刺手术包、穿刺针、引导丝、扩张管、深静脉导管(单腔、双腔或三腔)、缝合针线等,以及肝素生理盐水(生理盐水100ml+肝素6250U)和局麻药品(1%利多卡因或1%普鲁卡因)。 颈内静脉穿刺置管操作步骤 患者去枕仰卧位,最好头低15°~30°(Trendelenburg体位),以保持静脉充盈和减少空气栓塞的危险性,头转向对侧。 颈部皮肤消毒,术者穿无菌手术衣及手套,铺无菌单,显露胸骨上切迹、锁骨、胸锁乳突肌侧缘和下颌骨下缘。检查导管完好性和各腔通透性。 确定穿刺点:文献报道颈内静脉穿刺径路有13种之多,但常用中间径路或后侧径路(根据穿刺点与胸锁乳突肌的关系)。中间径路定位于胸锁乳突肌胸骨头、锁骨头及锁骨形成的三角顶点,环状软骨水平定位,距锁骨上3~4横指以上。后侧径路定位于胸锁乳突肌锁骨头后缘、锁骨上5cm或颈外浅静脉与胸锁乳突肌交点的上方。 确定穿刺点后局部浸润麻醉颈动脉外侧皮肤及深部组织,用麻醉针试穿刺,确定穿刺方向及深度。 左手轻柔扪及颈动脉,中间径路穿刺时针尖指向胸锁关节下后方,针体与胸锁乳突肌锁骨头内侧缘平行,针轴与额平面呈45°~60°角,如能摸清颈动脉搏动,则按颈动脉平行方向穿刺。后侧径路穿刺时针尖对准胸骨上切迹,紧贴胸锁乳突肌腹面,针轴与矢状面及水平面呈45°角,深度不超过5~7cm。穿刺针进入皮肤后保持负压,直至回抽出静脉血。 从注射器尾部导丝口插入引导丝(如用普通注射器则撤去注射器,从针头处插入引导丝),将穿刺针沿引导丝拔除。可用小手术刀片与皮肤平行向外侧(以免损伤颈动脉)破皮使之表面扩大。 绷紧皮肤,沿引导丝插入扩张管,轻轻旋转扩张管扩张致颈内静脉,固定好引导丝近端将扩张管撤出。 沿引导丝插入导管(成人置管深度一般以13~15cm为宜),拔除引导丝,用肝素生理盐水注射

实验一与实验二_血氧饱和度检测仪设计实验

YJ-02型医学电子教学仪器综合试验箱 第一部分综合实验箱简介 (2) 第二部分实验项目 (4) 实验一温度测试 ............................................................. 错误!未定义书签。 实验二心血管参数测试........................................... 错误!未定义书签。 实验三肺功能参数测试 ........................................... 错误!未定义书签。 实验四握力测试 .............................................................. 错误!未定义书签。 实验五血压测试 ............................................................. 错误!未定义书签。 实验六心电测试 ............................................................. 错误!未定义书签。 实验七血氧饱和度测试 (4) 实验八脉搏波波速测试 (12) 第三部分附录 .....................................错误!未定义书签。 一、心血管参数测试.......................................................... 错误!未定义书签。 二、肺功能参数测试.......................................................... 错误!未定义书签。 三、血压测量 ............................................................................ 错误!未定义书签。 四、接口器件--P D I U S B D12U S B................................. 错误!未定义书签。 五、软件及U S B驱动安装............................................. 错误!未定义书签。

心电、脉搏血氧饱和度(SpO2)监测技术操作流程

心电、脉搏血氧饱和度(S p O2)监测技术操作流程 1、操作者着装整齐、洗手、戴手套。 2、环境评估: 1)、操作者用手势示意(关闭门窗,遮挡病人)。 2)、大声说:“病房安静、室温22℃!” 3、病情判断、解释: 1)、核对病人,评估病情。大声说:_床×××,_疾病(疾病诊断),根据病情需要安置心电监护! 2)、上前小声对病人说:您好,请问您是_床×××吗?我是X护士,根据您的病情需要观察您的心电变化和机体组织缺氧状况,现在为您进行心电监护,这项操作没有什么痛苦,请您不要紧张,请您配合! 4、准备病人: 1)、病人取水平仰卧位。 2)、解开衣扣,暴露胸部。 3)、清洁皮肤。 4)、同时使用安慰用语:“现在请您放松,平卧,我要在您的皮肤上贴上电极板。现在我帮您解开衣扣清洁皮肤,可能感觉有点凉,请不要紧张。” 5、连接: 1)、接通电源。 2)、开机,进入备用状态。 3)、将连接好导联线的5个电极板贴到病人胸壁的相应部位上。 RA(白色):右锁骨中线锁骨下 LA(黑色):左锁骨中线锁骨下 LL(红色):胸骨左缘左锁骨中线第六肋间 RL(绿色):胸骨右缘右锁骨中线第六肋间 Y(棕色):剑突下方偏左心前区) 4)、将血氧饱和度导线与多功能参数监护仪相连接。 协助病人整理好上衣,盖好被子。 6、报告监护参数: 1)、监测心率: a、选择清楚的Ⅱ导联。 b、显示屏上出现心电图波,示窦性心律,律齐,心率110次/min。 c、大声说:心率110次/min! 2)、监测血压: a、缠绕血压袖带。 b、告知用语:现在为您测量血压,测量时会感觉上臂发紧,请你不要紧张。 c、启动无创测压键,测量首次血压。 d、显示屏上显示血压为110/70mmHg。 e、大声说:血压为110/70mmHg! 3)、监测S p O2: a、确认传感器性能(将探头夹在自己手指上,确认正常数值处于96%~98%)。 b、清洁指甲,把探头安放在患者左手示指上,指夹完全夹住左手示指末端,

血氧饱和度监测的常见问题及护理

血氧饱和度监测的常见问题及护理 主讲人: 参加时间: 参加人员: 血氧饱和度即SpO2被定义为氧合血红蛋白占血红蛋白的百分比值。常用动脉血氧定量技术,它测定的是从传感器光源一方发射的光线有多少穿过患者组织到达另一方接收器,这是一种无创伤测定血氧饱和度的方法。血氧饱和度读数变化是报告患者缺氧最及时、最迅速的警告。 一、血氧饱和度监测中的常见问题: 1、信号跟踪到脉搏,屏幕上无氧饱和度和脉率值。原因: (1)患者移动过度,过于躁动,使血氧饱和度参数找不到一个脉搏形式;(2)患者可能灌注太低,如肢体温度过低、末梢循环太差,使氧饱和度参数不能测及血氧饱和度和脉率; (3)传感器损坏; (4)传感器位置不准确(接头线应置手背,指甲面朝上); (5)血液中有染色剂(如美蓝、荧光素)、皮肤涂色或手指甲上涂有指甲油,也会影响测量精度; (6)环境中有较强的光源。如手术灯、荧光灯或是其他光线直射时,会使探头的光敏元件的接受值偏离正常范围,因此需要避强光。必要时探头需遮光使用; (7)探头戴的时间过长以后,可能影响血液循环,使测量精度受影响; (8)另外,同侧手臂测血压时,会影响末梢循环而使测量值有误差。 2、氧饱和度迅速变化,信号强度游走不定可能由于患者移动过度或由于手术装置干扰操作性能。 3、氧饱和度显示传感器脱落 (1)传感器如在位且性能良好,应注意连接是否正常,临床最常出现此种情况即液体溅进传感器接头处; (2)血氧探头正常工作,开机自检后探头内发出较暗红光或红光较亮且闪烁不定。 二、血氧饱和度监测中常见问题的处理: 1、信号跟踪到脉搏,屏幕上无氧饱和度和脉率值时的处理 (1)密切观察患者病情; (2)使患者保持不动或将传感器移到活动少的肢体,使传感器牢固适当或进行健康人测试,必要时更换传感器; (3)必要时对所测患者注意保暖; (4)需要避强光; (5)时间过长可换另一手指测量; (6)尽量避免同侧手臂测血压。 2、氧饱和度迅速变化,信号强度游走不定时的处理尽量使患者保持安静少动,

经皮测血氧饱和度说明书

经皮测血氧饱和度(SPO2)说明书 1、血氧饱和度监护说明SpO2 监护的定义 SpO2容积描记参数测量动脉血氧饱和度,也就是氧合血红蛋白总数的百分比。例如,如在动脉血的红细胞中,占总数97%的血红蛋白分子与氧结合,则此血液就有97%SpO2血氧饱和度,监护仪上的SpO2值读数应为97%。SpO2值显示出形成氧合血红蛋白的携氧血红蛋白分子的百分率。SpO2容积描记参数还能提供脉率信号和容积描记波。 SpO2 容积描记参数测量原理 血氧饱和度用脉动血氧定量法测定。这是一种连续的、无创伤测定血红蛋白氧合饱和度 的方法。它测定的是从传感器光源一方发射的光线有多少穿过病人组织(如手指或者耳朵),到达另一方的接收器。传感器可测量的波长通常红色LED是660nm,红外线LED是940nm。LED的最大可选输出功率是4mW。 穿过的光线数量取决于多种因素,其中大多数是恒定的。但是,这些因素之一即动脉血 流随时间而变化,因为它是脉动的。通过测定脉动期间吸收的光线,就可能获得动脉血液的血氧饱和度。检测脉动本身就可给出一个“容积描记”波形和脉率信号。在主屏上可以显示“SpO2”值和“容积描记”波形。 本手册中的SPO2是指通过无创方法测得的人体功能血氧饱和度。 警告 如果存在着碳氧血红蛋白,高铁血红蛋白或染料稀释化学药品,则SpO2值会有偏差。 Sp02容积描记参数测量 ■在主屏上可以显示“Sp02”值和“容积描记”波形。 ■本手册中的SP02是指通过无创方法测得的人体功能血氧饱和度。 如果存在着碳氧血红蛋白,高铁血红蛋白或染料稀释化学药品,则Sp02值会有偏差。 血氧饱和度/脉搏监护 电外科设备的电缆不能与传感器电缆缠绕在一起。 不要把传感器放在有动脉导管或静脉注射管的肢体上。 不要将血氧探头与血压袖套血压测量放在同一肢体上,因为血压测量过程中血流闭塞会影响血氧饱和度读数。 ■确保指甲遮住光线。■探头线应该置于手背。 ■ Sp02值总显示在固定地方。■脉率仅在如下情况下显示: 1) 在ECG菜单中将“心率来源”设定为“SP02”或“全选”。 2) 在ECG菜单中将“心率来源”设定为“自动”,且此时没有ECG信号。 Sp02波形与脉搏量不成比例。 在开始监护以前,应先检查传感器电缆是否正常。当把Sp02传感器电缆从插口上拔去时,屏幕将显示“传感器脱落”的错误信息,并同时触发声音报警。 如果传感器包装或者传感器有受损的征象,则不要使用此Sp02传惑器,应把它退还给厂家。连续的,过长时间的监护可能会增加不希望发生的皮肤特征变化的危险,例如异常敏感、变红、起泡或压迫性坏死,特别是在新生儿或是在具有灌注障碍以及变化的或不成熟皮肤形态图的病人身上。特别要注意根据皮肤的质量变化,正确的光路对准和贴附方法来检查传感器安放位置。要定期地检查传感器贴附位置并在皮肤质量下降时改变贴附的位置。由于个别病人状态的不同,可能要求进行更频繁的检查。 2、血氧饱和度监护操作方法 Sp02容积描记测量 1) 打开监护仪; 2) 把传感器贴在病人手指的适当位置上;3) 把传感器电缆线一端的连接器插Sp02孔。

中心静脉血氧饱和度监测技术资料

中心静脉血氧饱和度监测 技术资料 PCCI 飞利浦医疗保健 2011‐05‐25

目 录 1.参考文献 2.操作指南 附:CeVOX导管引导色标 CeVOX导管技术参数 CeVOX导管使用问答

Open Access Available online https://www.360docs.net/doc/fd7571583.html,/content/10/6/R158 Page 1 of 8 (page number not for citation purposes) Research Multicentre study on peri- and postoperative central venous oxygen saturation in high-risk surgical patients Collaborative Study Group on Perioperative ScvO2 Monitoring Received: 5 Jul 2006Revisions requested: 27 Jul 2006Revisions received: 30 Aug 2006Accepted: 13 Nov 2006Published: 13 Nov 2006Critical Care 2006, 10:R158 (doi:10.1186/cc5094) This article is online at: https://www.360docs.net/doc/fd7571583.html,/content/10/6/R158 ? 2006 Collaborative Study Group on Perioperative ScvO2 Monitoring; licensee BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (https://www.360docs.net/doc/fd7571583.html,/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.For a complete list of authors and their affiliations, see Appendix. Corresponding author: Stephen M Jakob Abstract Introduction Low central venous oxygen saturation (ScvO 2) has been associated with increased risk of postoperative complications in high-risk surgery. Whether this association is centre-specific or more generalisable is not known. The aim of this study was to assess the association between peri- and postoperative ScvO 2 and outcome in high-risk surgical patients in a multicentre setting. Methods Three large European university hospitals (two in Finland, one in Switzerland) participated. In 60 patients with intra-abdominal surgery lasting more than 90 minutes, the presence of at least two of Shoemaker's criteria, and ASA (American Society of Anesthesiologists) class greater than 2,ScvO 2 was determined preoperatively and at two hour intervals during the operation until 12 hours postoperatively. Hospital length of stay (LOS) mortality, and predefined postoperative complications were recorded. Results The age of the patients was 72 ± 10 years (mean ±standard deviation), and simplified acute physiology score (SAPS II) was 32 ± 12. Hospital LOS was 10.5 (8 to 14) days,and 28-day hospital mortality was 10.0%. Preoperative ScvO 2decreased from 77% ± 10% to 70% ± 11% (p < 0.001)immediately after surgery and remained unchanged 12 hours later. A total of 67 postoperative complications were recorded in 32 patients. After multivariate analysis, mean ScvO 2 value (odds ratio [OR] 1.23 [95% confidence interval (CI) 1.01 to 1.50], p = 0.037), hospital LOS (OR 0.75 [95% CI 0.59 to 0.94], p = 0.012), and SAPS II (OR 0.90 [95% CI 0.82 to 0.99],p = 0.029) were independently associated with postoperative complications. The optimal value of mean ScvO 2 to discriminate between patients who did or did not develop complications was 73% (sensitivity 72%, specificity 61%). Conclusion Low ScvO 2 perioperatively is related to increased risk of postoperative complications in high-risk surgery. This warrants trials with goal-directed therapy using ScvO 2 as a target in high-risk surgery patients. Introduction Several randomised controlled clinical studies have shown improved morbidity and mortality in high-risk surgical patients with perioperative optimisation of haemodynamics using strict treatment protocols in the single-centre setting [1-3]. The haemodynamic endpoints in goal-directed studies have been based on values derived from the pulmonary artery catheter [1-4], oesophageal Doppler [5-10], or (very recently) lithium indi-cator dilution and pulse power analysis [11]. Central venous oxygen saturation (ScvO 2) and mixed venous oxygen satura-tion (SvO 2) have been proposed to be indicators of the oxygen supply/demand relationship. However, the relationship between SvO 2 and ScvO 2 remains controversial [12]. Venous oxygen saturations differ among organ systems because dif-ferent organs extract different amounts of oxygen. It is there-fore conceivable that venous oxygen saturation depends on the site of measurement [13]. Redistribution of blood flow and alterations in regional oxygen demand (for example, in shock,severe head injury, general anaesthesia, as well as microcircu-latory disorders) may affect the difference between ScvO 2 and SvO 2. Although ScvO 2 principally reflects the relationship of oxygen supply and demand, mainly from the brain and the upper part of the body [13], it correlates reasonably well with concomitantly measured SvO 2 [12,13], which is more dependent on changes in oxygen extraction in the gastrointes-tinal tract. HDC = high-dependency care; ICU = intensive care unit; LOS = length of stay; OR = odds ratio; ROC = receiver operator characteristic; SAPS II = simplified acute physiology score; ScvO 2 = central venous oxygen saturation; SvO 2 = mixed venous oxygen saturation.

血氧饱和度测量仪的设计

血氧饱和度测量仪的设计

血氧饱和度测量仪 的设计

目录 摘要 (3) 第一章绪论 (4) 1.1血氧饱和度的基本概念 (4) 1.2血氧饱和度测量仪课程设计的意

义 (3) 1.3血氧饱和度测量仪课程设计的技术要求 (4) 1.4基本步骤 (5) 1.4.1理论依据 (5) 1.4.2硬件电路的设计 (6) 1.4.3软件设计 (6) 1.4.4仿真及数值定标 (6) 第二章实验方案设计及论证 (6)

2.1设计理论依据 (6) 2.2.双波长法的概念 (6) 2.3光电脉搏传感器 (7) 2.4传感器可能受到的干扰 (9) 2.5实验方案设计 (10) 第三章硬件电路的设计 (10) 3.1硬件原理框图 (10) 3.2各部分电路的设

计....................................................................................1 1 第四章软件模块设计.......................................................................................1 3 4.1主程序流程图..........................................................................................1 4 4.2子程序流程图..........................................................................................1 4 4.3硬件调试 (16) 第五章设计收获及心得体会 (17) 第六章参考文献 (19) 附录程序清单…………………………………………………

血氧饱和度探头检测的基本原理

血氧饱和度探头检测的基本原理 氧是维系人类生命的基础,心脏的收缩和舒张使得人体的血液脉动地流过 肺部,一定量的还原血红蛋白(HbR)与肺部中摄取的氧气结合成氧和血红蛋白(HbO2),另有约2%的氧溶解在血浆里。这些血液通过动脉一直输送到毛细血管,然后在毛细血管中将氧释放,以维持组织细胞的新陈代谢。血氧饱和度(血氧探头)(SO2)是血液中被氧结合的氧合血红蛋白(HbO2)的容量占全部可结合的血红 蛋白(Hb)容量的百分比,即血液中血氧的浓度,它是呼吸循环的重要生理参数。而功能性氧饱和度为HbO2浓度与HbO2 Hb浓度之比,有别于氧合血红蛋白所占百分数。因此,监测动脉血氧饱和度(血氧探头)(SaO2)可以对肺的氧合和血红 蛋白携氧能力进行估计。 1、血氧饱和度检测分类 血氧浓度的测量通常分为电化学法和光学法两类。 传统的电化学法血氧饱和度测量要先进行人体采血(最常采用的是取动脉血),再利用血气分析仪进行电化学分析,在数分钟内测得动脉氧分压(PaO2),并计算出动脉血氧饱和度(SaO2)。由于这种方法需要动脉穿刺或者插管,给病 人造成痛苦,且不能连续监测,因此当处于危险状况时,就不易使病人得到及 时的治疗。电化学法的优点是测量结果精确可靠,缺点是比较麻烦,且不能进 行连续的监测,是一种有损伤的血氧测定法。 光学法是一种克服了电化学法的缺点的新型光学测量方法,它是一种连续 无损伤血氧测量方法,可用于急救病房、手术室、恢复室和睡眠研究中。目前 采用最多的是脉搏血氧测定法(Pulse Oximetry),其原理是检测血液对光吸收 量的变化,测量氧合血红蛋白(Hb02)占全部血红蛋白(Hb)的百分比,从而直接 求得SO2。该方法的优点是可以做到对人体连续无损伤测量,且仪器使用简单 方便,所以它已得到越来越普遍的重视。缺点是测量精度比电化学法低,非凡 是在血氧值较低时产生的误差较大。先后出现了耳式血氧计,多波长血氧计及 新近问世的脉搏式血氧计。最新的脉搏式血氧计的测量误差已经可以控制在1%

血氧饱和度

经皮血氧饱和度监护 血氧饱和度(SO2)是血液中被氧结合的氧合血红蛋白(HbO2)的容量占全部可结合的血红蛋白(Hb)容量的百分比,即血液中血氧的浓度,它是呼吸循环的重要生理参数。动脉氧分压(PaO2)与动脉血氧饱和度(S O2)的关系呈“S”形曲线(Bohr效应),PaO2 在7.98KPa(60mmHg)时,即可达到90%。新生儿呼吸功能障碍等严重疾病易导致缺氧血氧饱和度和氧分压降低,使病情加重,因而临床上主要通过经皮血氧饱和度监测等,了解机体缺氧状况并作出及时正确的评估和处理。 工作原理 经皮血氧饱和度监护仪的探头分夹型和带型两类,各有多种规格,可安置在手指、足趾、耳垂和耳翼等部位。在通过检测充血人体末梢组织如手指或耳垂等部位对不同波长的红光和红外光的吸光度变化率之比(R/IR值)推算出组织的动脉血氧饱和度(SaO2),按照Beer-Lambert定律,比值R/IR与动脉血氧饱和度(SaO2)的函数关系应为线性关系,但由于生物组织是一种强散射、弱吸收、各向异性的复杂光学系统〔2~4〕,不完全符合经典的Beer-Lambert定律,因而导致了表达红光和红外光吸光度相对变化测量值(R/IR值),与动脉血氧饱和度(SaO2)之间关系的数学模型建立困难。只能通过实验的方法来确定R/IR与SaO2的对应关系,即定标曲线。大多数脉搏血氧仪生产厂家都以实验方法获取经验定标曲线以完成产品出厂前的预定标。 适应证 有血管疾病的人(冠心病.高血压.高血脂.脑血栓……..)、有呼吸系统疾病的人(哮喘.气管炎.老慢支.肺心病。。。。。。)、60岁以上的老年人、每天工作超过12小时的人、极限运动及高山缺氧环境下的血氧监测、长期酗酒人群 使用方法 采用指套式光电传感器,测量时,只需将传感器套在人手指上,利用手指作为盛装血红蛋白的透明容器,使用波长660 nm的红光和940 nm的近红外光作为射入光源,测定通过组织床的光传导强度,来计算血红蛋白浓度及血氧饱和度,仪器即可显示人体血氧饱和度,为临床提供了一种连续无损伤血氧测量仪器。 注意事项 1. 用经皮血氧饱和度监测仪红外线探头固定在患者指端,监测到患者指端小动脉搏动时的氧合血红蛋白占血红蛋白的百分比。 2. 注意事项:第一,使用时应固定好探头,尽量使患者安静,以免报警及不显示结果。第二,严重低血压、休克等末梢循环灌注不良时,可影响其结果的准确性。

混合静脉血氧饱和度之欧阳光明创编

混合静脉血氧饱和度 欧阳光明(2021.03.07) 拉丁学名:Oxygen Saturation of Mixed Venose Blood;SvO2 相关疾病:循环衰竭;败血症;心源性休克;甲亢;贫血及变性血红蛋白症;脓毒症 【参考值】 68%~77%;平均75% 【临床意义】 通过测定混合静脉血氧饱和度(SvO2)来计算动静脉血氧含量差,能较准确反映心排出量。Waller等曾指出SvO2和心脏指数、每搏指数及左心室每搏指数之间有很高的相关性。SvO2下降,而动脉血氧饱和度和耗氧量尚属正常时,则可证明心排血量也是低的。因此现在认为混合静脉血的氧饱和度检查对严重心肺疾患的监测具有重要价值。 SvO2增高的常见原因是脓毒症,此外氰化物中毒及低温也可使SvO2增高。

SvO2降低的原因有:心输出量下降导致的血循环量不足、周围循 环衰竭、败血症、心源性休克、甲亢、贫血及变性血红蛋白症、肺部疾患等各种原因导致的氧合功能减低者。SvO2低于60%时,通常提示组织耗氧增加或心肺功能不佳。 临床上连续测定SvO2对危重患者的监测起到重要作用,并对治疗方法及药物使用也有一定的指导作用 Nuclear factor kB (NF-kB) is a nuclear transcription factor that regulates expression of a large number of genes that are critical for the regulation of apoptosis, viral replication, tumorigenesis, inflammation, and various autoimmune diseases. The activation of NF-kB is thought to be part of a stress response as it is activated by a variety of stimuli that include growth factors, cytokines, lymphokines, UV, pharmacological agents, and stress. In its inactive form, NF-kB is sequestered in the cytoplasm, bound by members of the IkB family of inhibitor proteins, which include IkBa, IkBb, IkBg, and IkBe. The various stimuli that activate NF-kB cause phosphorylation of IkB, which is followed by its ubiquitination and subsequent degradation. This results in the exposure of the nuclear localization signals (NLS) on NF-kB subunits and the subsequent translocation of the molecule to the nucleus. In the nucleus, NF-kB binds with a consensus sequence (5'GGGACTTTCC-3') of various genes and thus activates their transcription. IkB proteins are phosphorylated by IkB kinase complex consisting of at least three proteins; IKK1/IKKa,

心电监护仪——血氧饱和度监测的注意事项

心电监护仪——血氧饱和度监测的注意事项 一、血氧饱和度的定义 血氧饱和度(SpO2)是血液中被氧结合的氧合血红蛋白(HbO2)的容量占全部可结合的血红蛋白(Hb)容量的百分比,即血液中血氧的浓度,它是呼吸循环的重要生理参数。常用动脉血氧定量技术,它测定的是从传感器光源一方发射的光线有多少穿过患者组织到达另一方接收器,这是一种无创伤测定血氧饱和度的方法。血氧饱和度读数变化是报告患者缺氧最及时、最迅速的警告。计算公式如下:SpO2 = HbO2/(HbO2+Hb)×100%。氧饱的正常值为95%-100%,氧饱与氧分压直接相关。 二、血氧饱和度的测定方法 血氧饱和度的测量通常分为电化学法和光学法两类。 1、电化学法即行人体采动脉血,再用血气分析仪测出血氧饱和度值,这是一种有创的测量方法,且不能进行连续的监测。 2、光学测量法是采用光电传感器的无创方法,是基于动脉血液对光的吸收量随动脉搏动而变化的原理进行测量的,该方法使用最多的就是脉搏血氧饱和度仪。仪器探头的一侧安装了两个发光管,分别发出红光和红外光,另一侧安装一个光电检测器,将检测到的透过手指动脉血管的红光和红外光转换成电信号。由于皮肤、肌肉、脂肪、静脉血、色素和骨头等对这两种光的吸收系数是恒定的,只有动脉血流中的HbO2和Hb浓度随着血液的动脉周期性的变化,从而引起光电检测器输出的信号强度随之周期性变化,将这些周期性变化的信号进行处理,就可测出对应的血氧饱和度,同时也计算出脉率。 三、SpO2报警值的设置 SpO2正常值,吸空气时SpO2测得值≥95%~97%。低氧血症:SpO2<95%者为去氧饱和血症,SpO2<90%为轻度低氧血症,SpO2<85%为重度低氧血症。一般报警低限的设置应高于90%。 四、血氧饱和度监测中的常见问题 1、信号跟踪到脉搏,屏幕上无氧饱和度和脉率值。

解析血氧饱和度的监测

解析血氧饱和度的监测 血氧饱和度(oxygen saturation,SO2 或Sat )和体温(temperature)、脉搏(pulse)、呼吸(respirations)、血压(blood pressure,BP)以及疼痛评估(pain assessment)并列为咱们人体的六大生命体征。现在让我们来解决一直困扰大家的相关问题吧! 什么是血氧饱和度? 给大家讲个故事吧!从前有一个氧国,氧们都住在肺泡里;还有一个血红蛋白国,血红蛋白们都泡在血浆里,住在一列永远流动的叫血管的火车上。 氧的命运就是要嫁给血红蛋白,他们会等着血管列车开过来进到车里选爱人。 有很小的一部分氧不愿意接受命运的安排,溶解到血浆里消失了(形成了PaO2,Partial pressure of oxygen 动脉血氧分压,当外界氧分压降低或者呼吸功能出现问题的时候首先消耗的溶解在血浆内的氧,然后再利用与血红蛋白结合的氧);剩下的氧都会挑选到心仪的血红蛋白,组成CP。

但是并不是每一个血红蛋白都被选中,没有被氧看上的血红蛋白就成了单身汪(默哀)那么,现在就剩下一道小学数学题,血红蛋白现在分成了已婚人士和单身汪,求已婚人士占全体血红蛋白的比例。。。。。。这个比例就是血氧饱和度。

怎么会有两个血氧饱和度?SaO2 (arterial oxygen saturation)动脉血氧饱和度和SpO2 (peripheral oxygen saturation)外周血氧饱和度的区别? SaO2这个指标主要出现在咱们动脉血气检查(arterial blood gas test)里。是有创检查,需要通过动脉抽血获得(首选桡动脉,其次是肱动脉和股动脉); SpO2则通过脉搏血氧饱和度仪(pulse oximeter)放置到身体末梢的毛细血管上获得(一般选手指、耳垂、婴儿足部的毛细血管)。

相关文档
最新文档