HighPoint’s SSD7105 is the fastest and most versatile NVMe RAID storage upgrade for PCIe Gen3 computing platformsMay 2022, Fremont, CA- HighPoint launches the SSD7105; the industry’s fastest bootable PCIe 3.0 x16 4x M.2 NVMe RAID solution. The SSD7105 is an ideal storage upgrade for any PCIe Gen3 desktop, workstation and server platform, and introduces several new features designed to streamline integration workflows, including a high-efficiency cooling system with full fan control, comprehensive Linux support, a new 1-Click Diagnostic solution, and our innovative Cross-Sync RAID technology.The compact controller is smaller than your average GPU yet can directly host up to four off-the-shelf2242/2260/2280/22110 double or single-sided M.2 NVMe SSDs, in one or more bootable RAID configurations. A single SSD7105 can support up to 32TB of storage at 14,000MB/s. Two SSD7105’s in a Cross-Synced RAID configuration can double these numbers; up to 64TB @ 28,000MB/s; faster than most PCIe Gen4 NVMe controllers!Replace aging SAS/SATA Infrastructure with Proven NVMe TechnologyNow is the best time to replace aging SAS/SATA storage infrastructure. NVMe technology is no longer restricted to niche applications or exotic hardware platforms; it is now well established and readily available.M.2 NVMe media, in particular, is more versatile and affordable than ever before. In many cases, M.2 SSDs are less expensive than their SAS/SATA counterparts. M.2 NVMe SSDs are now available with up to 8TB of capacity, and the performance advantages are immediately obvious; you would need 5 of today’s fastest SAS/SATA SSDs to keep up with your average M.2 drive, and 20 or more to match a simple 4x M.2 RAID 0 configuration hosted by theSSD7105! And thanks to the lack of moving parts, NVMe media is inherently more efficient and reliable than platter-based hard disk drives.All-in-one Performance and Security upgrade for any PCIe 3.0 Workstation & ServerThe vast majority of computing platforms in service today rely on PCIe 3.0 host connectivity. And the reason is simple - PCIe 3.0 is tried and true. The technology is mature; cost-effective, highly reliable and still capable of delivering excellent performance. Compatibility concerns are minimal, and solutions are available for nearly any application, budget and working environment.The SSD7105 allows you to squeeze every last drop out of your PCIe Gen3 host platform without compromising reliability – in fact, it can drastically improve efficiency and uptime of your server or workstation. In addition to the massive performance boost made possible by NVMe technology, the SSD7105’s Redundant RAID 1 and 10 capability can shield your bootable volume and mission critical data against the threat of hardware failure. Industry’s Only Bootable 4-Port PCIe 3.0 x16 NVMe RAID ControllerThe SSD7105 is the industry’s fastest bootable NVMe RAID solution for PCIe Gen3 host platforms. It is capable of delivering up to 14,000MB/s of transfer performance using off the shelf M.2 SSDs. The four independent ports and dedicated PCIe bandwidth ensure each SSD can operate at full speed, concurrently.And unlike most bootable NVMe controllers, which are restricted to specific platforms or configurations, the SSD7105 is no one-trick pony; it is an independent, multi-purpose, bootable NVMe RAID solution, and is capable of accommodating an enormous number of high-performance storage applications.For example, an administrator could configure each SSD to operate independently as a stand-alone boot drive. This type of configuration could be used to host a cost-effective Virtualization solution based around Hyper-V or Proxmox.The SSD7105 is also capable of hosting multi-RAID configurations, such as a secure, bootable RAID 1 volume alongside a blazing fast RAID 0 array tailored for a specific software suite or application. The possibilities are nearly endless!Need more than 14,000MB/s?HighPoint’s Cross-Sync Technology delivers Gen4 performance in a Gen3 package!HighPoint’s revolutionary Cross-Sync NVMe RAID technology allows administrators to combine two independent PCIe 3.0 RAID controller cards to function as a single device; effectively doubling your transfer bandwidth and storage capability!The process is seamless and entirely transparent to the host system. The Windows or Linux OS will recognize the two 4-port cards as a single 8-Port NVMe device. A dual-card Cross-Synced SSD7105 configuration can host up to 64TB of storage and deliver up to 28,000 MB/s of transfer performance – exactly what you would expect from today’s fastest 8-port PCIe Gen4 controllers!Works with all Major Windows and Linux PlatformsThe SSD7105 is fully compatible with all major Windows and Linux based operating systems. Comprehensive device driver support is available for Windows 11 and 10, Server 2022 and 2019, and Linux Distributions such as RHEL, Debian, Ubuntu, Fedora, Arch, Proxmox and Xenserver.In addition, we offer Binary driver development services, and Open-Source driver packages for other or non-standard distributions.Linux Binary Driver Packages are developed specifically for a particular distribution and kernel. Binary drivers are easy to install, even for novice Linux users.Linux Open-Source Package with Auto-Compilation packages are ideal driver for most Linux applications. The administrator need only install the root package; the driver will handle all future updates automatically, such as checking/monitoring the status of kernel releases, preparing the system environment, recompiling a new driver, and installation.macOS Support for Non-bootable storage configurations - SSD7105 is compatible with 2019 Mac Pro’s and legacy 5,1 workstation platforms, and can be used to host non-bootable NVMe SSDs and RAID arrays. Device drivers are available for macOS 10.x and 11.x.Advanced NVMe RAID EngineThe SSD7105’s advanced NVMe RAID engine is capable of supporting bootable RAID 0, 1, 10, arrays and single-drives, including mixed configurations of single-disks and arrays, multiple arrays, multiple boot volumes, and boot + storage configurations.RAID 0 (Striping) - Also known as a “stripe” array, this mode delivers Maximum Performance and capacity by linking multiple NVMe SSD's together to act as a single storage unit.RAID 1 (Mirroring) - This mode creates a hidden duplicate of the target SSD, and is ideal for applications that require an extra layer of data security.RAID 10 (Security & Speed) - RAID 10 offers the best of both worlds. Two RAID 1 arrays are striped together to maximize performance. RAID 10 is capable of delivering read performance on par with RAID 0, and is superior to RAID 5 for NVMe applications. Unlike RAID 5, RAID 10 doesn’t necessitate additional parity related write operations, which reduce the DWPD/TBW life span of NVMe SSDs.Ultra-Quiet Active Cooling Solution with Full Fan ControlThe SSD7105’s advanced cooling system combines a full-length anodized aluminum heat sink with an ultra-durable, near-silent fan, and high-conductivity thermal pad. This compact, ultra- efficient solution rapidly transfers waste heat away from critical NVMe and controller componentry, without introducing unwanted distraction into your work environment.Full Fan Control – By default, the SSD7105’s cooling system will automatically adjust fan speed to ensure NVMe media operates within their recommended temperature thresholds. However, advanced administrators can opt for full manual control. The WebGUI management suite provides 3 selectable speed settings, including an option to fully disable the fan. This feature is ideal for media and design applications that require low-noise or silent working environments, and utilize platforms already equipped with robust cooling systems.Thunderbolt™ Compliant NVMe RAID SolutionThe SSD7105 is fully Thunderbolt™ compliant, and is compatible with PCIe expansion chassis capable of hosting a standard full-height, full-length PCIe device such as the RocketStor 6661A. This enables the SSD7105 to host data-only SSD and RAID configurations for Mac platforms with Thunderbolt™ 3 connectivity.Comprehensive Monitoring & Management SuiteHighPoint believes that you should not need a professional IT background to configure, monitor and maintain NVMe and RAID storage configurations. Two comprehensive user interfaces are included with each SSD7105 RAID controller.The WebGUI is a simple, intuitive graphical user interface designed to work with all modern Web Browsers. It is equipped with Wizard-like quick configuration menus as well as a suite of advanced tools for expert administrators.The CLI (Command Line Interface) is ideal for seasoned administrators or platforms that do not utilize graphical operating systems.The WebGUI’s SHI Feature (Storage Health Inspector) allows administrators to instantly check the operating status of NVMe SSDs in real-time, such as temperature, voltage and TBW (Total Bytes Written). TBW tracking in particular, is essential for maintaining the long-term health of NVMe storage configurations. NVMe media have finite write capability; once the TBW threshold has been reached, the NVMe SSD should be replaced to avoid the risk of a write failure.Event & Error Logging with Email Notification: Each interface includes automated event logging with configurable Email Event NotificationIntelligent 1-Click Self-Diagnostic Solution: HighPoint’s Web-based graphical management suite (WebGUI) now includes a host of automated diagnostic tools designed to streamline the troubleshooting process, even for novice administrators. Customers no longer have to manually assemble a collection of screenshots, logs and status reports when submitting support inquiries. 1-click enables the interface to gather all necessary hardware, software and storage configuration data and compile it into a single file, which can be transmitted directly to our FAE Team via our Online Support Portal.Pricing and AvailabilityThe SSD7105 is slated for release in late May of 2022, and will be available direct from the Highpoint eStore and our North American Resale and Distribution partners.SSD7105 4xM.2 Bootable PCIe 3.0 x16 NVMe RAID Controller: MSRP: USSD$399.00。
Prostar 3920 RAID Manual说明书

为用户提供可扩展的高性能存储和满意的服务Prostar 3920 磁盘阵列Prostar 存储系统基于开放系统而设计,采用最新设计理念。
在数据高可靠性、高可用性、高性能,高灵活性的系统配置,完善的管理功能等诸多方面都有非常出色的表现。
模块化设计基于先进的模块化设计,系统在容量和性能方面提供极大的灵活性。
每个机箱占3U空间,可容纳16个硬盘。
随着用户需求的增长,可以方便地接 4Gb SBOD来扩展存储容量,最多可级联到7个机箱共112个硬盘,采用光纤300G硬盘最大容量33.6TB;采用SATA2 750GB硬盘最大容量为84TB。
支持在线扩容,保证数据完整性,减小系统宕机风险。
安全可靠的设计理念支持热插拔冗余RAID控制器,端口旁路和冗余环境监测电路。
具有电池保护的镜像高速写缓存,大功率电源和冷却系统。
支持多目标ID,双内部独立通道同时联接所有硬盘从而支持自动错误切换和恢复。
LUN屏蔽,高速缓存镜像以及ECC内存最大限度地保证数据的完整性和可靠性。
简单易用的存储管理软件SANtricity存储管理软件可以使用户花费很低的管理成本,实现统一管理。
在任何地方都可以灵活管理,只需一个接口就可以管理整个PS系列存储平台,使系统得以实现无缝升级。
管理软件集成了分区和复制的功能,通过配置文件可灵活的实现增加容量、性能调整、存储合并、数据复制等功能。
灵活多变,更加人性化的4G光纤通道磁盘阵列Prostar 3920存储设备为SAN 和集群环境提供最佳的性能和数据有效性。
可以进行多种配置使用户可以在容量,性能和功能等方面来更改配置以适应各种需求,如高速持续输出的视频系统和多I/O 操作的数据库系统和OLTP 等。
4GB双控制器集成控制并结合智能管理软件,建立了高性能的存储系统。
3920存储系统是Prostar中端存储产品的最新成员。
3920将最先进的4Gb/s端到端光纤通道(FC)技术,融入企业级RAID存储系统的设计,开发了一款多功能的存储系统,并使性能、扩展性和可用性最大化。
瓦里安系列4-瓦里安LCMS八大特点

Pressure Gauge
完美的真空锁定装置 Plug Ion Volume Tool
Vacuum Inlet Solenoid
完美的真空锁定系统
➢ PC监控下巧妙实现真空锁定;
➢ 保证在不切断真空的前提下实现EI源、正/负CI源或 ➢ ESI源、APCI源之间快速容易的切换; ➢ 大大缩短了离子源的切换时间,同时保证了真空系统的长寿命使用。
❖
6°倾角设计排除了毛细管引入的溶剂分子,有效降低背景干扰,提高
信噪比;
1200L LC/MS的八大特点 (二)
(二)专利涡流设计的高效、省气的APCI源
剖面图
专利涡流设计的高效、省气的APCI源
雾化针
热的辅助气的扰动流使雾化粒子 束在石英管内快速蒸发
专利涡流设计的高效、省气的APCI源
剖面图 气体 流动相 气体
APCI 加速去离子簇效应的快速完成 防止大颗粒液滴直接进入取样毛细管 在适当的操作下,对于APCI源应该不存在大颗粒液滴
宽孔径、金属毛细管
N2 气体加热器
离子 颗粒
毛细管
宽内径(0.4 mm)使离子 传输最大化
1 L/min
不锈钢毛细管减少电荷集结的可能, 更有利于离子的通过
1200L LC/MS的八大特点 (三)
❖ 186mm长程设计确保较宽的 CID能量范围,可有效的将稳定的 离子二次解离;
❖ 外加74mm的超长前、后预杆设 计,能最大限度稳定维持CID区域 内的碰撞气压,实现二极质谱高 的分析重复性;
❖ 弯曲设计最大限度缩小真空空间, 最大程度延长分子涡轮泵的使用 寿命。
❖ 检测器与离子源不在同一水平 面上,防止检测器被沾污,去 除中性物质,极大降低化学噪 声,
高性能 6Gb s 和 12Gb s SAS SATA 硬盘阵列主机适配器用户手册说明书

RocketRAID 2700 PCI-Express 2.0 x8HBA seriesSAS/SATA 6Gb/s RAID Host AdaptersUser’s GuideRevision: 2.3Jul. 23, 2015HighPoint Technologies, Inc.CopyrightCopyright © 2012 HighPoint Technologies, Inc. This document contains materials protected by International Copyright Laws. All rights reserved. No part of this manual may be reproduced, transmitted or transcribed in any form and for any purpose without the express written permission of HighPoint Technologies, Inc.TrademarksCompanies and products mentioned in this manual are for identification purpose only. Product names or brand names appearing in this manual may or may not be registered trademarks or copyrights of their respective owners. Backup your important data before using HighPoint's products and use at your own risk. In no event shall HighPoint be liable for any loss of profits, or for direct, indirect, special, incidental or consequential damages arising from any defect or error in HighPoint's products or manuals. Information in this manual is subject to change without notice and does not represent a commitment on the part of HighPoint.NoticeReasonable effort has been made to ensure that the information in this manual is accurate. HighPoint assumes no liability for technical inaccuracies, typographical, or other errors contained herein.TABLE OF CONTENTS1 FEATURES AND SPECIFICATIONS (4)2 Physical Specifications (5)3 Kit Contents (5)4 Hardware Description and Installation (6)4.1 RocketRAID 272x/271x Host Adapter board layout (6)4.2 Connector and Jumper description: (7)4.3 Installing the RocketRAID Host Adapter (7)4.4 Verifying Installation (8)5 RocketRAID BIOS Utility (9)5.1 BIOS Settings Overview (9)5.2 Using the BIOS Utility (9)5.3 BIOS Commands (9)5.4 Creating RAID Arrays (10)5.5 Deleting Arrays (13)5.6 Adding/Remove Spare Disks (13)5.7 Settings (14)6 HighPoint Software CD (15)7 RocketRAID 272x/271x Driver Installation (16)7.1 Driver installation -Windows (16)7.2 Driver installation -Linux and FreeBSD (19)8 HighPoint Web RAID Management software (20)8.1 Installing the Web RAID Management software (20)8.2 Installing OS X Driver and Web RAID Management Software (21)8.3 Starting Using the Web RAID Management Software (21)9 Thank You (22)10 CUSTOMER SUPPORT (23)HighPoint RocketRAID 272x/271x – PCI-Express 2.0RocketRAID 272x/271x Host AdaptersThe RocketRAID 272x/271x host adapters are high-performance SAS RAID solutions, delivering reliability to demanding data-intensive applications such as tiered storage environments, security and surveillance, video editing, and digital content creation.Support for both 6Gb/s SAS and SATA drives on the same controller maintains configuration optimization for performance based on the characteristics of SAS and SATA drives available today.HighPoint RAID Management HighPoint RAID Management software offers a user friendly interface to create, manage and maintain your storage solutions. Email notification and remote are some of the advance features that the RAID Management software has to offer.1 Features and SpecificationsHost Adapter Architecture•PCI-Express x8 (Gen2)•Support up to 4/8 SAS/SATA drives• 1 Internal Mini-SAS Connectors (SFF-8087) (RocketRAID 2710)• 1 External Mini-SAS Connector(SFF-8808) (RocketRAID 2711)• 2 Internal Mini-SAS Connectors (SFF-8087) (RocketRAID 2720)• 1 External Mini-SAS Connector (SFF-8088) / 1 Internal Mini-SAS Connector (SFF-8087) (RocketRAID 2721)• 2 External Mini-SAS Connectors (SFF-8088) (RocketRAID 2722)•Hot Swap and hot plug•Low Profile•RoHS complaintAdvanced RAID Features•Supports RAID 0, 1, 5, 6, 10,50 and JBOD•NCQ (Native Command Queuing)•Auto detect of unplug/plug SAS/SATA hard drive for RAID auto rebuild•Staggered drive spin up•HDD bad sector repair and remapping•Support Disk Scrubbing•BIOS Booting (INT13) to RAID array for better redundancy•64bit LBA for RAID arrays greater than 2TB single partition•S.M.A.R.T array monitoring for hard drive status and reliabilityArray Monitors, Alerts and Indicators•Hard Drive LED Indicators (Activity and Failed) (except RocketRAID 2711/2722)•SMTP email notification for events and error reporting•Alarm/Buzzer alerts for drive/array failure•SAF-TE (I2C) and SGPIO enclosure managementRAID Management•Online Capacity Expansion (OCE) and Online RAID Level Migration (ORLM) forWindows/Linux/FreeBSD•Quick and Background initialization for instant RAID access•API library for customization•CLI (Command Line Interface) for Linux and FreeBSD•Web GUI RAID management (local and remote monitoring)•Online array roaming•SHI (Drive analysis driven from S.M.A.R.T)HighPoint RAID Management (HRM)•Hot key (ctrl-h) boot-up RAID manager via BIOS•Web browser-based RAID management software (Web GUI)•Command Line Interface (CLI)Operating System Support•Windows 7, 8, 8.1, 10 / Windows Server 2008, 2012•Linux (Fedora Core, Red Hat Enterprise / CentOS, SuSE, Debian, Ubuntu)•FreeBSD•OS X (for RocketRAID 2711, 2721 and 2722 only)2 Physical SpecificationsDimensions:Size: 96.3mm X 65.0mm (RocketRAID 2710/2720)Size: 120.0mm X 68.0mm (RocketRAID 2711/2721/2722)EMI: FCC Part 15 Class B and CEThermal and Atmospheric Characteristics:Work Temperature Range: +5 C ~+ 55 CRelative Humidity Range: 5% ~ 60% non-condensingStorage Temperature: -20 ~ +80 CMTBF: 920,585 HoursElectrical Characteristics:PCI-E 3.3V 12VPower 4W max 1W max3 Kit Contents•RocketRAID Host Adapter•Quick Installation Guide•HighPoint Software CD•Low-profile bracket4 H4.1 R ardware DRocketRAID DescriptioD 272x/271x on and Instx Host Adap tallationpter board l layoutRocketRAID 2720RocketRAID 2721RocketRAID 2710RocketRAID 27114.2 CConnector /descriptionJ1A1 or A2F1 or F2BEEP1PORT1~ POR (Mini-SAS Po A 4.3 I Note The R the lo 1.O 2.R 3. G c Connector a / JumperRT3ort) Active/FAIL LE This connecto requirement Installing th e: Make sure t RocketRAID 27ow-profile bra Open the syst Remove the P Gently insert t chassis (illustr and Jumper RocketRA 2710 Active LED Fail LED P SFF-808D PIN connect or is one-pin c and display in he RocketRA he system is p 72x/271x inclu acket in place em chassis an PCI slot/bracke the RocketRAI ration shows R r descriptio AID Rock 2D PIN PIN 87 SFF tor :connection fro nformation, pl AID Host Ad powered-off b udes both stan of the standa nd locate an un et cover.ID card into th RocketRAID 27R o cketRAID 2722nketRAID 2711 R I2N/A A N/A A F-8088om HBA to LED ease refer to:dapterbefore installin ndard and low rd bracket, de nused PCI-E x8he PCI-Express 720).RocketRAID 2720 2C connector ctive LED PIN Fail LED PIN Alarm buzzer SFF-8087 D on chassis. Fng the RocketR w-profile brack epending upon 8(or PCI-E x16s slot, and sec RocketRAID 2721 Active LED P Fail LED PIN SFF-8087 &SFF-8088 For detail LED RAID host ada kets. It may be n the chassis d 6)slot.ure the bracke D RocketRA IN N/A N N/A & SFF-8connectionpter.e necessary to design.et to the syste AID 2722A A 088 o attach em/PDF/LED_connection.pdf4.A No att ma5. 4.4 V Once that t 1. w 2.P After installing ote: Many serv tached to the anual for prop Close and sec Verifying In e the host ada the hardware Power on the will be displayPress “Ctrl”+”g the adapter,ver-level chass chassis backp per installation cure the system nstallationpter and hard is properly re e system. If the yed during booH” key combi , attach hard d sis include har lane, rather th n procedures.m chassis.d drives have b ecognized.e system dete ot up.nation to acce drives to the h rd-drive hot-sw han directly to been installed ects the preseness the Rocket host adapter.wap bays. For o each individu into the chas nce of the adatRAID adapter these system ual hard drive.sis, boot-up th apter, the Roc r’s BIOS Utility chassis, cable . Consult the c he system to v ketRAID BIOS y.es are chassis verifyUtility5 Ro The R BIOS drive chec Press .5.1 B The R and c 5.2 U The f Alt –Arrow Enter Esc –5.3 B CreatDeletAdd/capa SettiView ocketRAID RocketRAID 27 Utility will dis es are detecte k the power a s “Ctrl”+”H” ke BIOS Settin RocketRAID 27controller rela Using the B following keys – press Alt to h w keys – use t r – Open the s – move back to BIOS Comm te - this comm te - this comm /Remove Spar ble of using sp ngs - this com w– this comm D BIOS Uti 72x/271x cont splay informat d by this utilit and cable conn ey combinatio gs Overview 72x/271x cont ated settings.BIOS Utilitys utilized by th highlight the to these to move selected toolb o the previous mandsmand is used t mand will dele re - this comm pare disks to a mmand opens tand is used to ilitytroller will disp tion about har ty. If any of the nections.on to access th wtroller BIOS ut e RocketRAID ool bar.e between diff bar command/s menu, cance o open the RA te the selecte mand is used to automatically the settings mo select betwe play its BIOS s rd drives attac e hard drives a he RocketRAID tility is an inte D 2700 BIOS ut ferent menu it /execute the s el the selected AID Creation m d RAID array. o assign hard rebuild broken menu (selectingeen two views creen during t ched to the ad are not detect D adapter’s BIO erface that pro tility:temselected comm operation, or menu. disks to functi n or faulted RA g the boot diss: Devices (HA the system's b dapter. Make s ted, power do OS Utility.ovides manage mand.r exit the BIOS ion as spare d AID arrays.sk/array, staggARD DISKS), an boot process. T sure all attach own the system ement comma S Utilityisks. The cont gered drive spind Arrays (con The hed m and ands troller is inup)nfiguredRAID Initia they 5.4 C Initi Befor confi ENTE Highl each and acreat Warn disks CreaSelec D arrays).alize - this com can be used t Creating RA alizing Disk re creating a iguration info ER.light the targe selected disk ask you to pre te RAID arrays ning: Initializa s that do not c ating Arraysct Create from mmand is used to create array AID Arraysks:RAID array, rmation to th et disks using t k.Once all tar ess Y (yes) to s.tion will destr contain critical s:m the toolbar a d to prepare d ys.the disks m he hard disks.the arrow key rget disks have initialize, or N roy all pre- exi l data.and press Ente disks for use w ust be initial . Select the In ys, then select e been selecte N (no) to canc isting data oner.with RAID array ized. Disk ini nitialize comm using Enter. A ed, press ESC.cel. Once initithe selected h ys. Disks must tialization wr mand from th A numeral wil The utility w ialized, thesehard disks. On t be initialized rites necessar he toolbar, an l be displayed will display a w disks can benly initialized before ry RAID d press d before warning,used to1.U2.U w Note name3. Od Use the arrow Use the arrow will appear. U e: the Array Na ed at a later ti On the Createdevice list will w keys to selec w keys to highl Use the keyboa ame command ime, and the n e menu, use thl appear, and d ct the RAID lev ight the Array ard to input a d is optional –name of the a he arrow keysdisplay all ava vel and press E y Name option new Array Na – it is not nece rray can be ch to highlight thailable hard dis ENTER.n and press En ame, and pres essary to name hanged at any he Select Devsk drives.nter. The array ss the Enter ke e the array. Th time.icesitem and y name dialog ey.he array can bpress Enter. A gue boxbeA4. H d b5. N c d y Noteyou t as a s 6.F Write Write at th 7.S W s 8.Tp Highlight the t displayed befo been selected Next, Use the capacity will b disk space for you wish to se e: Multiple arr to set aside di single disk (by For redundant e Back – utiliz e Through – w e cost of lowe Sector Size – A Windows oper size. Do not u To complete tpress Enter. Pr target disks th ore each selec d and press the ↓ arrow key be displayed. P additional arr et aside for thi ays can be cre sk space that y the operating t RAID arrays zes disk cache writes directly er performanc Also known as rating system.se if the opera he creation pr ress the Y(yes hat you want t cted disk. This e ESC key to re to highlight th Press ENTER if rays/single dis is particular a eated using th be used to cre g system).(RAID 1, 5, 10(higher perfo to the disks (m ce).s “Variable Sec . This allows o ating system a rocedure, use s)key to creat to use, and pre s number desi eturn to the C he Capacity (G f you wish to u sks, use the ke rray, and pres he same set of eate another a ), select the C rming)may reduce th ctor Size”. Use older operatin already suppo the arrow keyte the array, o ess Enter to se ignates disk or Create Menu.GB) option and use all availab eyboard to inp ss Enter.f hard disk driv array, set as a Cache Policy:he risk of data e this option i ng systems to orts large volu y to highlight or N(no) key to elect them. A rder. After all d press Enter. le space. If yo put the amoun ves. The Capac spare disk, or a loss during a f you are usin support volum mes (such as G the Start Creao cancel the c numeral will b of the disks h The total ava u wish to rese nt of space (in city option all r partitioned t critical failure g an older 32-mes over 2TB iGPT).ation item andcreation proce beave ilableerve GB) ows to act e, but -bitin dess.5.5 D Highl The B Enter The uWarn5.6 A This A to au RAID Spareremo Deleting Ar light the Delet BIOS utility w r.utility will disp ning: all data Adding/Rem Add/Remove utomatically re D arrays, disks e Disk, use theove the Spare rrayste command f will display a lis play a warning stored on the move Spare Spare comma ebuild Redund must be initia e arrow keys tDisk setting fr from the toolb st of available g message. Pre e array will be e Disksand is used to dant RAID arra alized before t to select the tarom a hard dis bar, and press e RAID arrays.ess Y (yes) to lost – do not assign a hard ays (RAID 1, 5,hey can be us arget disk fromsk, highlight th Enter.. Select the ar delete the arr delete if the disk to act as , 10) in the cas sed as spares. m the list of inhe spare disk, rray you wish ray, or select N array contain a Spare Disk. se of disk failu To set a hard nitialized disksand press Ent to delete, an (no) to cance ns critical data Spare Disks a ure. As with cr d disk to act as s, and press Enter.nd press el. a. re used reating s anter. ToGene Howe spare time 200Gthis e be se 5.7 S To ac Selec the c Staggpowe settin WarnIf ena erally, single d ever, in some e.If the disks of creation, t GB hard disks, example, 200G et as spares fo Settingsccess the Setti ct Boot Device card to act as t gered Drive Sp er up the hard ng – consult th ning: Westernabled, these d isks are design e instances, di in question a hese disks ma but only 200GB of disk spa or a separate r ings menu, hig e – select whic the boot devic pinup – This o d disks, sequen he disk docum n Digital hard ddisks may not nated to act a sks that are m re part of a RA ay be used as s GB of space (ace remains un edundant arra ghlight the Set ch disk or arra ce.option is disab ntially (one dis mentation for m disks do not sube detected b s spares (disks members of R AID array that spares. For exa out of a grand nallocated. Th ay that falls int ttings comma ay will act as th bled by default sk approximat more informa upport this setby non-RAID co s that are not RAID arrays m t did not utiliz ample: a RAID d total of 400his unallocated to the same c nd from the t he boot disk, i t.Enabling th tely every 2 se tion.tting. Enablinontroller.configured int may also be de ze the full ava D 0 array was c GB), was assig d space would apacity range oolbar, and pr if the motherb is setting will econds). Not ang this setting to RAID arrays esignated to a ilable capacity created betwe gned to that a d allow these (200GB).ress Enter.board BIOS ins instruct the ca all disk suppois not recomm s).act as a y at the een twoarray. In disks to structs ard to rt thismended.6 H Each This for a Crea To cr1.I2.I3.C4.C m5. C o6.C ighPoint S retail box inc CD can be use variety of ope ating a drive reate a driver Insert the CD Insert a blank Click on “Crea Click on the “P model from th Click on the “P operating systClick on the “O Software C ludes a copy o ed to generate erating system er diskettefloppy diskett into the syste floppy diskett te Driver Disk Please Select a he list.Please Select t tem from theOK” button to CDof the HighPoi e driver disket ms.te: m’s CD/DVD d te into the sys kette”.a Product” dro the Diskette y list.create the dr int Products S ttes, and insta drive. The prog stem’s floppy op-down butto ou want to creriver diskette.oftware CD.all the HighPo gram should s drive.on, and selecteate” drop-do int RAID Mana start automati t the appropri own button, a agement Utilit ically.ate host adap nd select the ty Suite pter desired Windows / Windows Server and several distributions of Linux and FreeBSD require driver diskettes when installing the operation system directly to a disk or array hosted by the RocketRAID host adapter.7 Ro 7.1 D Insta 1.I V 2. WH W “3.W ocketRAID Driver insta alling the drive Install the Roc Vista.Windows shou Hardware” wi When Window “continue”.When asked to D 2700 Dri allation -Wi er for an exist cketRAID host uld automatic zard pop-up w ws asks: “Windo search onlin iver Instal ndowsting Windows adapter into t cally detect the window. Select dows needs yone select “Don llationoperating sys the PC, then b e card, and dis t “Locate and our permission’t Search Onli stemboot up Windo splay the “Fou install driver s n to continue”ne”.owsund New software”.”, select4.S5.a.Select “I don’tand then selec t have disc, shct “Browse my ow me othery computer fo options”.or driver softw ware”.6.B7.W Browse to theWhen asked “e location of th“Would you lik he driver and cke to install thi click “Next”.is driver softw ware?” select ““Install”.8. R r Insta1.Bo2.W drivesever 3.Se 4.Th will t 7.2 D Ple ins SoPle Reboot the sy reboots.alling the drive oot from the W hen the scree er” and browse ral media type lect the Rocke he driver is now then proceed n Driver insta ease refer to t stallation step oftware locatio /Driver/RR2ease always ch stem when pr er during a fre Windows Insta n “where do ye for the drive es: floppy disk etRAID 2700 c w installed – t normally.allation -Lin the Driver Inst ps.on (RocketRAI 272x_1x/Drivheck HighPoin rompted. The esh Windows llation DVD.you want to in er location. W kette, USB flas ontroller drive the disk or arr ux and Free tallation Guide D Software CD vernt website for RocketRAID h OS installatio nstall Window indows can in h disk or CD.er, and click “N ray will be rec eBSDe and README D):latest softwar ost adapter w on ws ” appears, c stall drivers fr Next ”.cognized as av E file under thre download.will be ready fo click “Load rom vailable disk spe driver packa or use after W pace. Window age for theindowsws setup8 HighPoint Web RAID Management SoftwareThe HighPoint RAID Management software provides RAID configuration and management features. The software can be installed from the HighPoint software CD. Browse to the location of the HighPoint RAID Management software.8.1 Installing the Web RAID Management SoftwareWindows1.Software location (RocketRAID Software CD):/HighPoint RAID Management Software/Web RAID Management/Windows2.Double click the “setup.exe” setup program to install the management software.3.After the setup is completed, double click the program shortcut on the Windows desktop to runHighPoint RAID Management software:Linux -Red Hat Enterprise/CentOS, Fedora Core, Open SuSELinux operating systems that support .rpm packages, allow you to double-click the HighPoint Web RAID Management .rpm file to start the installation process.1.Software location (RocketRAID Software CD):/HighPoint RAID Management Software/Web RAID Management/Linux2.Extract the .tbz file to the desktop, and browse to the appropriate .rpm file (there are 32 and 64-bitoptions).3.Double click the .rpm file – this should open the operating systems software installer. Enter theAdministrative password when prompted and proceed with installation.4.The package can also be installed manually, using a terminal. Log on in as “root”, open a terminal, andbrowse to the location of the .rpm file. Run the following command:5.# rpm -i hptsvr-https-1.4-10.i386.rpm (or hptsvr-https-1.4-10.x86_64.rpm)Linux -Debian/Ubuntu Linux DistributionsFor Debian/Ubuntu Linux distributions, you can use alien to convert the rpmpackages to a .deb package, then use "dpkg -i" command to install eachpackage. Some script files may be lost during the conversion process from rpm to .deb,so you may need to make manual corrections. .The following files will be installed/configured:/usr/bin/hptsvr - service program/etc/hptcfg - service config file/etc/rc.d/init.d/hptdaemon - service control script/usr/share/hpt/webguiroot - data filesIf there is no /etc/hptcfg present, you can add it manually using by using the “echo” command on the driver file name to /etc/hptcfg.For example:# echo hptiop.ko>/etc/hptcfgUninstalling the UtilityOpen a terminal, and use the following command:# rpm -e hptsvr-https8.2 Installing OS X Driver and Web RAID Management SoftwareThe RocketRAID 2711/2721/2722 is compatible with Mac OS X. The OS X software package includes the driver and Web GUI management utility.Please check for the latest software/driver packages.Driver updates are posted on the card’s product page, under the “Download Center” section.Please refer to the Installation Guide under the software package folder for installation steps.8.3 Starting Using the Web RAID Management SoftwarePlease refer to the online help of “How to Use Web RAID Management Software”:/help/9 Thank YouThank you for purchasing the RocketRAID 272x/271x SAS/SATA RAID Host adapter. We appreciate your support, and welcome any questions, comments or product suggestions you may have.10 Customer SupportIf you encounter any problems while utilizing RocketRAID series host adapters, or have any questions about this or any other HighPoint Technologies, Inc. product, feel free to contact our Customer Support Department.HighPoint Technologies, Inc. websites:/Web Support:/websupport/。
6qualLogic PS6210系列阵列

EqualLogic PS6210系列阵列∙概览∙服务与支持∙解决方案∙软件∙客户评级简化存储管理∙Dell EqualLogic PS6210阵列可使一般IT人员以较少的资源管理更多的数据。
此系列可与常见的应用程序环境紧密集成,而且十分灵活,能够与多种操作系统配合使用。
PS6210系列的设计特点如下:部署在VMware虚拟化环境、Exchange和SQL Server应用程序和分布式DAS实施中∙通过单个直观的界面与FS系列结合使用,支持块数据和文件数据∙支持服务器和桌面虚拟化∙有助于服务器/存储/网络整合,简化虚拟体系管理∙支持多路复制,提供可靠的灾难恢复功能可简化管理的全新软件Dell EqualLogic软件7.0虽然随PS6210阵列发布,但适用于整个PS系列;它是一种增强的固件,具有一系列工具来实现可靠的数据保护策略和存储管理、虚拟化及优化∙此EqualLogic主机软件扩展了基于阵列的软件的功能,可与主机操作系统、虚拟机管理程序和应用程序配合使用∙用于Microsoft®、VMware和Linux®产品的主机集成工具∙通过SAN HQ管理软件的界面可监控各组EqualLogic阵列,确保存储资源得到充分利用并通过SupportAssist集成到戴尔服务中空前出色的性能EqualLogic PS6210系列阵列具有EqualLogic产品系列的简洁性,可为中小型企业提供增强的存储性能。
对于连续的大数据块工作负载,每个Dell EqualLogic PS6210阵列最高可实现每秒2 GB的吞吐量。
1此外,EqualLogic PS6210阵列支持闪存,其随机性能最高可达前几代阵列的3倍。
2整个系列的PS6210系列阵列可为实际应用程序带来10 GbE的iSCSI SAN速度和效率,其特点如下:∙双控制器,每个控制器配备16 GB3的非易失性内存高速缓存∙两个10GBASE-T RJ45自动感应(10 Gb/1 Gb/100 Mb)端口∙两个10 GbE SFP+端口用于光纤或铜线连接∙最高配置24个热插拔驱动器,其中包括SAS、NL-SAS和固态硬盘∙设有支持2.5英寸驱动器和3.5英寸驱动器的机型供您选择∙每个阵列最高配置96 TB3的系统容量戴尔是全球排名第1的iSCSI存储供应商,4大约96%的客户会推荐EqualLogic。
希捷超大磁盘存储器

爲了大家能繼續YY MOD DIY 討論硬件大家可以繼續加群戀人的新群是:20102020这种服务器主机几个游戏服务器,种子山洪和运行免费图片托管设置为hardforums 。
它拥有400兆位的互联网连接,通过4网卡。
我也利用这个作为备份我的重要文件,这些文件在我的主页系统。
在未来的4x2.5英寸硬盘托架将成为固态硬盘(大概在1-2个月),以帮助降低了I / O负载的服务器上由播种山洪。
24.64TB安泰克超微的CSE - M35T - 1B签证的镰刀卡马变通范SA0925FDB12L安泰克EarthWatts 380W技嘉GA - MA74GM科技- S2AMD速龙X2处理器BE的2400年镰刀Zipang2 × 1GB的海盗船的DDR2 800MHz的TWIN2X2048 - 6400 GSyba的PCI 4 × SATA控制器卡的SD - SATA的四路6 ×西部数据鱼子酱绿色的1TB WD10EACS4 ×希捷Barracuda 7200.11 1.5TB ST31500341AS装甲运兵车智能UPS的SUA1500我用这台机器来备份我的主要的电脑和HTPC 。
我把希捷硬盘的底部,他们将获得更多的气流,我把西部数据硬盘上方, 5超微笼和低于它在5月25日湾。
我把风扇安静的超微笼子,然后我用一个老Fanmate控制器和抽气扇。
Antec Solo安泰克超微的CSE - M35T - 1B镰刀卡马变通范SA0925FDB12L安泰克EarthWatts 430W技嘉GA - E7AUM - DS2H英特尔Core 2 Duo E7200思民CNPS8700Thermalright人力资源- 05英飞凌与镰刀卡马变通范SA0825FDB12L海盗船2 × 2G的DDR2 800MHz的TWIN2X4096 - 6400C5 GHighPoint - RocketRAID 2320西部数据鱼子酱蓝640GB WD6400AAKS8 ×希捷Barracuda 7200.11 1.5TB ST31500341AS三星SH - S183的DVD ± RW光碟甲运兵车智能UPS的SUA1500Windows Vista旗舰版32位这是我的HTPC /文件服务器。
Dell Storage PS4210存储阵列白皮书

系列Dell ™ Storage PS4210 系列阵列提供了具有更大内存容量、更强性能和更多连接选项的下一代存储,既适合中小型数据中心、远程办公室,也适合当前的PS 系列环境。
PS4210 10 GbE iSCSI 阵列具有Dell PS 系列产品特有的行业领先功能,如简化的管理、多代兼容性和统包式软件许可等。
该系列可提供多种硬盘容量配置,在2U 机箱中最高可配置72 TB 的存储容量,并且提供2.5" 和3.5" 硬盘选项。
此外,PS4210 系列还可提供混合配置,以便将数据自动分层,将频繁访问的数据存储在固态硬盘上以实现快速响应,而将非常用数据存储在硬盘上,位于同一阵列内。
这将最大限度减少所需的固态硬盘数量,从而降低您的总成本。
经过优化的性能、容量和连接能力凭借在性能、容量和网络连接方面的丰富选择,Dell StoragePS4210 系列阵列可为您的小型数据中心或远程办公室提供易于管理的存储解决方案,该方案已针对虚拟化平台和各种应用程序进行了优化。
PS4210 系列可让您在 1 Gb 到 10 Gb 范围内进行自动协商,使您的环境更加易于管理 ;并允许您灵活地选择使用 SFP+ 或10 GBASE-T (铜缆)端口,从而充分利用现有基础架构或构建较低 成本的 10 GBASE-T 。
借助新的混合阵列,下一代 Dell Storage PS4210 系列的性能最高可比上一代产品提升 6 倍。
1 这些混合闪存阵列的随机读取性能最高可达 80,000,非常适合用于任务关键型工作负载,例如 VDI 部署、 OLTP 数据库和其他混合工作负载。
1企业级功能,便于日常使用PS 系列阵列基于虚拟化的模块化存储体系结构,因此您可以在需要时仅购买所需的存储容量。
完善而又简单的管理功能可加快 SAN 配置,内置的智能功能可感测网络连接、自动构建 RAID 集并执行系统运行状况检查。
所有 PS 系列阵列,不管是哪一代产品,都可以协同工作,进而在所有资源间自动管理数据和平衡负载,或在您添加新阵列时无缝扩展存储池。
HPE 3PAR StoreServ 7000配置指南

如果不需要盘柜高可用,那么 第一列中列出了每个 RAID 类 型的最小驱动器数。
14 16 18 20
24
18 e.
Y
Y
8+1
8+1
10 + 2
14 + 2
R1、R5、 R6
R1、R5、
15 e.
3PAR 7400 4 控制器配置
针对 4 控制器的建议配置选项
控制器对后的均衡盘柜
盘柜符合给定驱动器类别的 RAID 要求(R5 3+1 SAS、 SSD 需要 4 个盘柜;R6 6+2 SAS、SSD 或 NL (LFF) 需要 3 个盘柜) 升级具有相似驱动器配置的盘柜 升级跨所有盘柜按列进行
21 e.
建议的自适应优化 (AO) 配置
配置类型 2 层 SSD+SAS SSD 层 最少为容量的 2.5%1 最多为 IOPS 目标的 50%* 2 层 SAS+NL N/A SAS 10K/15K 层 容量的 97.5% 最少为 IOPS 目标的 50% 最少为容量的 40% 最多为容量的 60% NL 层 N/A
* SFF 和 LFF 盘柜的混合配置提供了其他的 SAS、SSD 和 NL HA 盘柜选项 - 应谨慎混合盘柜类型
16 e.
3PAR 7400 4 控制器配置
4 控制器和盘柜高可用最佳实践
如果您想最大限度地提高 HA 盘柜的可用性及 4 个控制器 的性能,那么建议考虑下面有关升级系统的一些附加注意事 项
(仅 RAID 1 或 RAID 5,RAID 6 需要 12 个驱动器)
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
LSI 7900BM存储服务器是全球首款发布并投入使用的8Gb全光纤磁盘阵列。
它是一种企业级存储服务器,旨在为当今高要求的数据密集型计算环境提供所需的性能和灵活性。
这一服务器的存储容量可达到256TB,非常适宜用于在线事务处理(OLTP)、数据挖掘和数字媒体这样的高性能应用。
LSI 7900BM在现有LSI系列磁盘存储系统功能的基础上创建,使用公共的存储管理界面和类似的磁盘扩展工具。
使用16个16位4GB SBOD磁盘机柜时,最多可支持256个光纤通道磁盘驱动器。
当与8Gb SAN交换机结合起来使用时,可使用LSI 7900BM创建一个完整的8Gb SAN环境。
此外,LSI 7900BM在性能方面超过了其它LSI存储服务器,磁盘吞吐速度达到6400MB/秒。
它还使用了高级的高速缓存算法来优化磁盘性能。
灵活多变,模块化设计,8G 光纤通道磁盘阵列
LSI 7900BM企业级存储设备为SAN 和集群环境提供最高的性能和数据有效性。
可以进行多种配置使用户可以在容量,性能和功能等方面来更改配置以适应各种需求,如高速持续输出的视频系统和多I/O 操作的数据库系统和OLTP 等。
双控制器集成控制并结合智能管理软件,建立了高性能的存储系统。
16个8Gb主机接口提供LOOP, Fabric和点到点等拓扑结构,支持各种流行的操作系统:包括Windows NT/2000/2003,IBM AIX、SUN Solaris 、HP-UNIX、Linux、Novell等。
更高级别ASIC芯片,提供高速硬件XOR运算和RAID运算满足客户各种性能需求,高达700,000 IOPS值可满足大型数据库应用,6400MB/s的带宽保证了大数据吞吐量的带宽要求。
16个4Gbps光纤磁盘通道,最大带宽6400MB/s,提供大数据吞吐量和高带宽应用。
高达8GB的高速缓存,电池后备。
8Gbps/s光纤主机通道,多处理器进程最佳化提升系统资源。
支持在线扩容,保证数据完整性,减小系统宕机风险。
支持热插拔冗余RAID控制器,端口旁路和冗余环境监测电路。
具有电池保护的镜像高速写缓存,大功率电源和冷却系统。
支持多目标ID,双内部独立通道同时联接所有硬盘从而支持自动错误切换和恢复。
LUN屏蔽,高速缓存镜像以及ECC内存最大限度地保证数据的完整性和可靠性。
无比灵活的管理配置,保证了系统的性能、容量的最大化,在线配置、在线扩展、在线性能调整和在线软件维护实现了系统的高可用性。
SANtricity存储管理软件可以使用户花费很低的管理成本,实现统一管理。
在任何地方都可以灵活管理,只需一个接口就可以管理整个LSI系列存储平台,使系统得以实现无缝升级。
管理软件集成了分区和复制的功能,通过配置文件可灵活的实现增加容量、性能调整、存储合并、数据复制等功能。
SANtricity软件独一无二的DAC存储技术为7900BM存储系统和所有LSI存储提供了卓越的功能。
有了DAC存储技术,数据配置将被保存到每一个磁盘当中,这种独有的设计能够保护数据的完整性、磁盘重组的灵活性。
即使打乱磁盘阵列的硬盘次序,数据也不会受到任何损害,磁盘阵列能够智能地识别硬盘位置,并正确获取所需数据。
避免数据人为丢失的可能性。
甚至DAC存储技术可以为我们提供卷组在不同LSI存储系统中进行迁移,这样我们就不必为数据系统的升级耗费大量的复制时间。
最新版管理软件提供系统实现高性能、高管理性,基于硬件的RAID计算和Cache 运算实现了基于硬盘的高速读写。
所有LSI系列产品,运行同样的软件,保证了客户的投资,可以实现无缝数据升级。
方便的集中管理和支持,降低了用户的管理费用。
LSI 7900BM 技术规格
控制器缓存
8GB ,支持电池后备
主机接口特性
支持光纤通道交换和FC 仲裁环路(FC-AL) 主机接口数量 16个8GB 磁盘接口特性
FC-AL 全交换模式 外形尺寸 4U 高19英寸机架设备(174.5mm H x 444.5mm W x 609.6mm D) 重量
43.9 公斤 支持硬盘容量
15000转300GB 、450GB 4G FC 7200
转750GB 、1TB SATA2 支持硬盘数量
256 每秒最大I/O (Cache) 每秒持续I/O (硬盘)
98,000IOPS 每秒最大传输率(Cache) 6400MB/s 6400MB/S 温度
10℃-40℃ 湿度
8%-80%(非凝结环境)
支持操作系统 Novell NetWare
Linux
SUN Solaris HP-UX 光纤设备支持 Brocade
MecData。