汗蒸房温控说明书
恒温控制器操作指南说明书

Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type.Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types,(select k -for type "K" CHROMEGA TM /ALOMEGA TM )J K T E N DIN J R S B C - TC types J k t E N dN J R S b C - DisplayStep 13. Store TC typeAfter you have selected the Thermocouple type press d to store your selection, the instrument automatically advances to the next menu item.Step 14. Enter to Reading Configuration MenuThe display shows RDG Reading Configuration, which is the top menu for 4 submenus: Decimal Point, Degree Units, Filter Constant and Input/Reading Submenus.Step 15. Enter to Decimal Point Submenu Press dto show DEC Decimal Point.Step 16. Display the Decimal Point positionPress d again to display the flashing Decimal Point position.Step 17. Select the Decimal Point position Press b to select FFF.F Decimal Point position.Step 18. Store selected Decimal Point positionBy pressing d momentarily the Decimal Point position will be stored and the instrument will go to the next menu item.Step 19. Enter to Temperature Unit Submenu Display shows TEMP Temperature Unit.Step 20. Display available Temperature Units Press d to display the flashing Degree °F or °C .Step 21. Scroll through Temperature Units selection Press b to select °F Degree.Step 22. Store the Temperature UnitPress d to display momentarily that the Degree Unit has been stored and the instrument will go automatically to the next menu item.Step 23. Enter the Filter Constant Submenu Display shows FLTR Filter Constant Submenu.Step 24. Display the Filter Constant Value Submenu Press d to display the flashing, previously selected Filter Constant.Step 25. Scroll through available Filter Constants Press b to sequence thru Filter Constants 0001, 0002,0004, 0008, 0016, 0032, 0064and 0128.Step 26. Store the Filter ConstantPress d momentarily to store 0004Filter Constant and the instrument will automatically go to the next menu item.Step 27. Enter Alarm 1 MenuPress a until the ALR1Alarm 1 Menu appears on the Display. In the following steps we are going to DisableLatch, Active Above, Deadband 020.0, and above Setpoint 1Value will activate Alarm 1.Step 28. Select Latch Type SubmenuPress d to display flashing DSBL / ENBL .If flashing DSBL is displayed, press a , if ENBL is displayed, press b until DSBL is displayed, then press d to store and go to the next menu item.Step 29. Select the Above Type of Active Submenu Press d . If flashing ABoV Above is displayed, press a ,otherwise press b until ABoV is displayed. Press d to store and advance to next menu item.WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 61 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal five (5) year product warranty to cover handling and shipping time. T his ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evalua-tion. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, includ-ing but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modifica-tion. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its vari-ous products. However, OMEGA neither assumes responsibil-ity for any omissions or errors nor assumes liability for any damages that result from the use if its products in accordance with information provided by OMEGA, either verbal or writ-ten. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY W ARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warran-ty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical appli-cations or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANT Y/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RE URNING ANY PRODUC (S) O OMEGA, PURCHASER MUS OB AIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPART MENT (IN ORDER T O AVOID PROCESSING DELAYS). T he assigned AR number should then be marked on the outside of the return package and on any correspondence.FOR WARRANTY RETURNS, please have the followinginformation available BEFORE contacting OMEGA:1. Purchase Order number under which the product was PURCHASED,2.3. Model and serial number of the product under warranty, and Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:1. P urchase Order number to cover the COST of the repair or calibration,2.3.Model and serial number of the product, and R epair instructions and/or specific problems relative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.OMEGA is a trademark of OMEGA ENGINEERING, INC.© Copyright 2018 OMEGA ENGINEERING, INC. All rights reserved. T his document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.MQS 3720/0818This Quick Start Reference provides information onsetting up your instrument for basic operation. Thelatest complete Communication and OperationalManual as well as free Software and ActiveXControls are available at or onthe CD-ROM enclosed with your shipment.The instrument is a panel mount device protected in accordance with EN 61010-1:2001, electrical safety requirements for electrical equipment for measurement, control and laboratory.Remember that the unit has no power-on switch. Building installation should include a switch or circuit-breaker that must be compliant to IEC 947-1 and 947-3. SAFETY:•Do not exceed voltage rating on the label located onthe back of the instrument housing.•Always disconnect power before changing signal andpower connections.•Do not use this instrument on a work bench withoutits case for safety reasons.•Do not operate this instrument in flammable orexplosive atmospheres.EMC:•Whenever EMC is an issue, always use shielded cables.•Never run signal and power wires in the same conduit.•Use signal wire connections with twisted-pair cables.•Install Ferrite Bead(s) on signal wire close to theinstrument if EMC problems persist.。
温控器说明书

温湿度控制器一、产品概述温湿度控制器,主要应用于需要对被测环境进行自动温湿度调节的场合,用户可通过按键分别调整温湿度的上、下限值来控制加热或排风实现自动控制,显示方式为数码管显示。
二、基本功能:2.1 温度测量范围:-25℃~+80℃±1℃;2.2 湿度测量范围:相对湿度RH: 0%~99% 精度±3%RH;2.3 控制方式:温度采用上、下限和回差控制,湿度采用上、下限控制,所有参数均可设置;2.4 输出控制类型:两组继电器触点,分别为加热和排风,每路最大负载AC250V /3A,均为有源输出。
三、技术指标:3.1电源:AC 220V±20%3.2 工作环境:温度:-25℃~+55℃,相对湿度:<95%RH3.3控制设定范围:温度:0℃~80℃,相对湿度:50%RH~99%RH3.4 本机功耗:<3W3.5自检功能:若数码管显示“–––”,则为检测到传感器故障;若加热或排风运行过程中相应指示灯熄灭,则检测到加热或排风故障。
四、工作原理:4.1 温度控制:当被测环境温度低于设定温度下限时,本仪器启动电加热设备开始加温,此时加热指示灯亮,温度升至比下限温度设定值高回差值时,即:W测≥W下限+回差,停止加温。
当被测环境温度高于设定温度上限时,本仪器启动降温设备(如风机或空调)开始降温,此时排风指示灯亮,温度降至比上限温度设定值低回差值时,即:W测≤W上限-回差,停止降温。
4.2 湿度控制:当被测环境湿度超过设定湿度上限时。
如果当前温度较高,即:W测≥W下限+(W上限-W下限)×3÷4,采用降温(或排风,视具体地区采用不同设备)抽湿,此时排风指示灯亮;抽湿过程中,如果温度低于下限温度+2度后,自动转为加热降湿;当降湿过程中温度高于上限温度-2度后,自动转为降温抽湿,直至湿度低于设定下限值为止。
当被测环境湿度超过设定湿度上限时。
如果当前温度较低,即:W测<W下限+(W上限-W下限)×3÷4,采用加热降湿,此时加热指示灯亮,降湿过程中,如果温度高于上限温度-2度后,自动转为降温抽湿;当温度低于下限温度+2度后,自动转为加热降湿,直至湿度低于设定下限值为止。
景邦汗蒸房使用说明书

景邦汗蒸房使用说明书1、首先配备匹配的空气漏电开关和单独的15A三孔插座不要与其他电器共用多头插座以免发生危险。
2、该仪器应竖立放置于坚硬、水平的地面上不可放在倾斜的地面上。
3、由于该仪器为木质产品严禁水淋。
在潮湿地面上使用时应与地面加隔离层确保该仪器不受潮湿。
4、用户电源插座按N、L接线。
5、仪器附近不得堆放易燃、易爆物品。
6、本机电源为220V加减22V,50Hz加减1Hz电源不符要求时需加装稳压设备。
仪器的使用及操作一使用注意事项1、检查线路和插座负荷及电压是否满足该仪器的要求。
2、该仪器的温控和时控应根据各人的具体情况选择合适的温度时间以时间不超过三十分钟温度40℃到60℃为宜。
3、为保持人体内水分进入仪器前最好先喝一杯水或饮料。
4、闭目静坐脸上出现汗珠后再体验15-20分钟为宜。
5、仪器连续工作4小时应停机1小时。
二操作方法1、先将仪器的插头插于单独的三孔插座上。
2、打开仪器开关及DVD开关电源指示灯DVD指示灯及照明灯亮。
3、按设置键开启仪器加热指示灯亮。
4、再按设置键进行温度调节此时设置灯亮。
5、最后按时间调节框中加或减键设置所需工作时间。
6、当仪器开启温度和时间设置完成后待温度升至您所需的温度即可使用。
当时间显示00时蜂鸣器报警仪器停止加热。
7、进入汗蒸房内用上述方法同样可以操作。
8、如感觉过于闷热可打开顶部的排气窗或门上的小窗户加以通风。
9、使用完毕后应关掉仪器开关。
安全注意事项1、严禁在仪器内晾晒衣物特别是在加热器前或上面放置毛巾、衣物等以免烤焦发生火灾。
2、进入仪器后请不要触及加热器以免烫伤或触电。
3、在仪器内请不要用手指触摸照明灯泡。
若须更换时要待冷却后在切断电源的情况下进行更换以免发生烫伤或触电。
有下列情况者禁止使用该仪器:1、严重伤口出血及溃烂炎症者。
2、严重眼科炎症患者轻微者可在眼睛上敷上浸水纱布、棉球后再用。
3、严重烧伤患者。
温控设备使用方法说明书

温控设备使用方法说明书一、产品概述本设备是一种用于控制温度的电子设备,适用于各种需要温度控制的场合。
该设备具有精度高、操作简便等特点,可广泛应用于工业生产、实验室等领域。
二、产品特性1. 精确控制:本设备采用高精度的温度传感器和控制芯片,能够实时感知环境温度,并根据设定的参数实现精准控制。
2. 多功能显示:设备面板配备液晶屏幕,能够显示当前温度、设定温度以及操作状态和故障码等信息。
3. 安全可靠:设备具备过温保护功能,在温度超过设定范围时会自动切断电源,确保设备和环境的安全。
4. 高效节能:设备采用先进的节能技术,在达到设定温度后能够自动切换到低功耗模式,保证节能效果。
5. 多种控制模式:本设备支持多种控制模式,可根据实际需求选择恒温、程序、循环等模式。
三、产品使用说明1. 设备安装:将本设备放置在平坦的表面上,确保通风良好,不与其他热源或易燃物接触。
保持周围环境清洁,避免尘埃或异物进入设备内部。
2. 设备连接:将电源线插入交流电源插座,并确保电源电压与设备要求相符。
设备须连接地线以确保安全。
3. 设备开机:将电源开关打开,设备将进入待机状态。
此时,液晶显示屏会显示当前室温。
4. 设备设置:按照设备使用场合的需要,通过屏幕上的按键进行参数设置。
根据具体说明书的内容,选择控制模式、设定温度、运行时间等参数。
5. 设备运行:确认参数设置无误后,按下启动键,设备将开始工作,并根据设定的温度进行自动控制。
6. 设备维护:定期清洁设备表面和内部,避免灰尘和杂质影响设备性能。
如发现设备出现故障,请及时断电并联系维修人员处理。
四、注意事项1. 请勿将设备长时间暴露在高温、潮湿或有腐蚀性气体的环境中,以免损坏设备。
2. 设备应放置在儿童无法触及的地方,以防不慎操作或触碰设备。
3. 设备故障时,请勿擅自拆卸修理,应联系售后服务中心或专业维修人员进行处理。
4. 设备在长时间不使用时,应断开电源并妥善保存,以延长设备寿命。
温控说明书

温控说明书温控说明书1. 简介温控是指通过控制系统自动调整温度,以满足特定的需求和要求。
温控系统广泛应用于各种场合,例如家庭、工业、农业等领域。
本文档将介绍温控系统的工作原理、使用方法以及常见问题解决方案。
2. 工作原理温控系统通过一系列传感器、控制器和执行器组成。
传感器用于感知环境的温度变化,控制器根据传感器的反馈信息决定是否调整温度,执行器则负责根据控制器的指令进行温度调节。
具体来说,温控系统的工作流程如下:1. 传感器感知环境的温度变化,将温度数据发送给控制器。
2. 控制器根据预设的温度范围,比较传感器反馈的温度数据与设定值,决定是否需要进行调整。
3. 若需要调整温度,控制器通过执行器发出指令,例如打开或关闭加热器、冷凝器等设备。
4. 执行器根据控制器的指令进行相应操作,调节温度至设定值。
5. 传感器不断监测环境的温度变化,循环执行上述步骤以维持恒温状态。
3. 使用方法以下是使用温控系统的步骤:1. 了解温控系统的工作原理和组成部分。
2. 将传感器安装在需要监测的位置,确保其能够准确感知温度变化。
3. 连接传感器与控制器,并确保其正常工作。
4. 配置控制器的设定值,即期望的温度范围。
5. 启动温控系统,等待系统开始自动调节温度。
6. 监测温度变化,如有需要,可以根据实际情况调整设定值。
7. 定期检查温控系统的运行状态,确保各组件正常工作。
8. 如需更改系统配置或修复故障,可参考温控系统的说明书或联系售后服务。
4. 常见问题解决方案4.1 温度不稳定可能原因及解决方案:- 传感器位置选择不当:重新选择合适的位置安装传感器,避免外部干扰或局部温度差异。
- 控制器设定值不准确:根据实际需求,重新设置设定值。
- 执行器故障:检查执行器是否正常工作,如有必要,更换故障执行器。
4.2 温度超过设定范围可能原因及解决方案:- 传感器故障:检查传感器是否正常工作,如有必要,更换故障传感器。
- 控制器故障:检查控制器是否正常工作,如有必要,更换故障控制器。
福美汗蒸房操作流程及注意事项

福美汗蒸房操作流程及注意事项1、汗蒸房在规定营业时间(如:13:00—22:00)前1小时开启,将温控器、远红外灯、负离子灯开关打开,须专人操作,汗蒸房每天工作不要超出12小时。
2、室内温度控制,随时查看房间内温湿度计,温控器初开时设定温度可以在50--56度(电热膜耐温范围在60度以下),等室内温度达到40-45度时,将温控器的设定温度调到45度左右。
(注:温控器控制的温度是加热部分即电热膜表面的温度,并非空气温度,通过调节温控器的温度也就是电热膜表面的温度,来达到空气温度在40-45度的范围。
)3、加湿器的开启,要看室内温湿度计的空气相对湿度显示,一般空气相对湿度控制在25-40%,高于40%时要关闭加湿器,汗蒸人员比较多的时候一般湿度较大。
4、汗蒸房要保持清洁卫生,汗蒸房开启前和关闭后,都要对坐凳、地面等地方用干净的半干毛巾擦拭干净,汗蒸的过程中,如果地面汗水较多,应及时清理,以免渗透地面,影响地下电路。
墙面和顶层不要用湿毛巾擦拭,如有脏污,用硬毛刷擦拭。
5、汗蒸房的墙面和地面有6-8层结构构成,其中都有电路加热系统,不要随意打钉、撞击及破坏表层结构,不然会造成破坏线路、漏电、短路等现象,严重的会引发火灾隐患。
6、不要在汗蒸房内随意洒水、点火,清洁时用的毛巾不要太湿。
汗蒸注意事项一、汗蒸前应保持身体清洁卫生,最好在沐浴和卸妆后进入汗蒸房。
二、不宜在过饱和空腹时汗蒸。
三、孕妇、妇女例假期间、儿童、严重外伤患者及严重疾病或传染病者不宜汗蒸。
四、有心脏搭桥、支架或严重心衰的患者,体内有钢板或钢钉的患者不宜汗蒸。
五、高血压患者汗蒸时间不宜过长,每次以15~20分钟为宜,可重复2~3次。
六、严禁携带手机、手表及精密仪器进入汗蒸房,温湿环境会对其产生影响。
七、汗蒸适量饮热水,汗蒸后2小时内不宜吃凉食和喝冷饮,8小时内不宜洗澡。
八、汗蒸时间30~60分钟为宜。
汗蒸房使用说明

汗蒸房使用说明汗蒸房是一种传统的健康养生方式,通过蒸汽的热效应,帮助促进血液循环、深层排毒、提高免疫力等。
为了更好地使用汗蒸房,我们提供以下使用说明,以确保您的安全和舒适:1. 准备在使用汗蒸房前,请先进行适当的准备。
首先,确保您的身体状况适合使用汗蒸房。
如果您有心脏病、高血压、妊娠、新近手术或其他健康问题,请在使用前咨询医生的建议。
2. 温度调整进入汗蒸房之前,请确保温度适宜。
一般而言,温度控制在40℃至50℃之间,根据个人体验和舒适度调整温度。
请注意,切勿将温度过高,以免造成身体不适或烫伤。
3. 时间控制在汗蒸房内的时间应适中,避免过度蒸浴。
初始使用时,可选择较短的时间,如10至15分钟。
随着适应和体验的增加,您可以逐渐延长使用时间,但也不可超过30分钟。
适度的时间可有效发挥汗蒸房的功效,而过长时间会对身体造成负担。
4. 准备工具在使用汗蒸房时,您可能需要准备以下工具来提高使用体验和效果:- 浴巾:用于擦拭身体和汗水。
- 毛巾或坐垫:可用于保护座椅或凳子,让您坐得更加舒适。
- 饮水:使用汗蒸房会出汗较多,及时补充水分十分必要。
请准备足够的饮水,并在使用过程中适时饮用。
5. 使用步骤在进入汗蒸房之前,请确保您已经解除身上的金属及首饰物品,并更换适合的衣物,如浴巾或泳衣。
接下来,您可按以下步骤进行使用:- 步骤一:在进入汗蒸房之前,先淋浴清洁身体,保持干净的状态。
- 步骤二:进入汗蒸房后,根据个人喜好选择座椅位置。
注意,不要靠近蒸汽出口以避免过热和不舒适。
- 步骤三:坐在座位上,轻松自然地呼吸,放松身心。
- 步骤四:适应汗蒸房的温度和湿度,让身体逐渐适应环境。
- 步骤五:享受蒸汽的效果,放松肌肉,让身体自由出汗。
- 步骤六:使用过程中,随时调整温度和湿度,保持舒适感。
6. 注意事项在使用汗蒸房时,请注意以下事项:- 保持适当的水分摄入:出汗较多会导致身体脱水,因此及时补充水分非常重要。
- 不要过度使用:每周使用1至3次为宜,过度使用可能对身体健康产生负面影响。
汗蒸房管理.doc

山东安然纳米实业发展有限公司汗蒸房的管理汗蒸房的管理一、汗蒸房的温度控制与使用方法温度控制,是管理好汗蒸房的重要环节之一。
温度的灵活控制与疗效、节能关系密切。
温度过低,疗效差;温度过高,既浪费电,还可能对皮肤造成灼伤。
汗蒸房内最佳温度为41度到43度。
汗蒸房的温度控制主要分为地面温控系统和墙壁温控系统。
温控又分为自动温控系统和手动温控系统。
自动温控系统价格比手动温控系统贵,但使用方便。
其操作程序如下:1.先合上汗蒸房电源总闸,接通汗蒸房全部线路,使电流畅通无阻。
2.使用自动温控系统的汗蒸房,只要将室内温度设置在38度到43度之间即可;使用手动系统的汗蒸房,要将温度调整至41度到43度后,不能置之不管,要经常检查室内温度变化情况,随时根据温度高低调整温控系统,以保证室内温度始终保持在实施汗蒸疗法的最佳温度。
3.当室内温度达到38度时,顾客即可进入汗蒸房内。
4.顾客进入汗蒸房内,要先站立,双臂上举10到15分钟,让上肢末梢部分皮肤充分接触生物波和负离子;地面远红外线电热膜产生的温热直接作用于足底部涌泉穴,以尽快打通周身经络气血,使微循环畅通。
站立结束后,可根据顾客自己需要或坐或卧。
5.汗蒸时,人体最好保持与墙壁10cm距离,便于生物波和负离子亲密接触人体肌肤,以提高疗效。
6.汗蒸时,要嘱咐顾客少说话或者不说话,静静的体会和享受生物波、负离子调整身体和出汗排毒时轻松、舒适等快感,并不断地小口饮用纳米水或者碱性水以加速毒素排泄,补充流失的水分和电解质。
7.汗蒸时,要有一名服务人员在汗蒸房内陪同客人,主要是向顾客解说汗蒸知识,指导汗蒸方法、注意事项,发现汗蒸中出现的一些问题,就地及时解决。
8.汗蒸结束后,及时关闭电源,先关闭温控系统,最后关闭总闸。
二、汗蒸疗法的注意事项和禁忌1.肺结核活动期、癌症晚期、年龄过高、神智不清、严重出血性疾病、心脏安装起搏器患者、心脏搭桥手术患者、饮酒过量导致呕吐或者昏迷者和妊娠等禁止使用汗蒸疗法。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
汗蒸房温控说明书
1
2020年4月19日
BT8000-B汗蒸房控制箱使用说明书“汗蒸”这一健康方式的问世,迅速得到了广泛地普及,各类汗蒸房也如雨后春笋般遍布大街小巷。
然而汗蒸房是一项技术含量极高的设施,正确的控制方式不但能保证安全、长期稳定地运行,同时还可提高舒适效果,达到保健康复功效。
BT8000-B型大功率汗蒸房综合控制箱,采用韩国技术标准设计,是一款分区域温度控制、过热保护、短路保护等功能、照明控制的综合控制器,适用于各类汗蒸房、桑拿房的综合温度控制。
一、技术参数及功能介绍
1.供电电压:交流380V或交流220V
2.最大输出功率:最大输出功率:30KW;其中回路1输出:20KW;回路2输出:10KW。
3.温控范围:
(1)室温控制(回路1):5-85℃
由放置于棚下部位的温度传感器“RT1”检测室内空气温度,当室温高于上限设置温度时,自动停止墙面“回路1”加热,当室温低于下限温度设置时,自动启动“回路1”加热。
(2)墙面过热保护:60℃
预埋在墙面内部的温度传感器“RT3”检测墙面温度,当墙面温度高于60℃时,强制停止墙面(回路1)的加热,用以保护加热体不至于温度过高而损坏或引起火灾,当墙面温度低于55℃时,回路1恢复正常工作。
(3)地温控制:5-85℃
由放置于地面下的温度传感器“RT2”检测地面温度,当地温高于上限温度设置时,自动停止地面(回路2)的加热,当地温低于下限设置
文档仅供参考,不当之处,请联系改正。
温度时,自动启动回路2加热。
二、安装说明
请严格按接线示意图接线(见附图1、附图2)
1.本产品电子集成度较高,请不要在潮湿的环境下使用。
2.将控制器放置在汗蒸房外面,不要在高于60℃的环境下使用,否则对机器
的使用寿命将会产生很大影响。
3.“RT1”是检测空气温度的传感器,应放置于天棚下方3cm处,并将其可
靠固定。
4.“RT3”是测量墙面温度的过热保护器,其作用为防止墙面温度过高,而
损坏加热体或引起火灾。
应将其放置于墙面与保温层间,距离加热体旁约3cm处,并将其穿入穿线管中,切勿将其线及探头直接接触水泥砂浆。
5.“RT2”是测量地面温度的传感器,将其放置于地面与保温层间,距离加热体旁约3cm处,并将其穿入穿线管中,切勿将其线及探头直接接触水泥砂浆。
三、操作说明
1.电源开关
机箱内部设有空气开关,可开启或关闭总电源。
2.开关机
在控制器开机状态下,按[开/关]键,温控器进入关机状态,清除所有显示,同时,加热设备断电,温控器保存关机前的工作参数。
在温控器关机状态下,按[开/关]键,温控器进入开机状态,并按关机前设定的参数运行。
3.双温切换
2
2020年4月19日。