德龙ECO310 说明书

合集下载

MICROTEC CA310多功能传感器说明书

MICROTEC CA310多功能传感器说明书

Housing: swivelling (30°)Material: ABS V0 as per UL94Protection: IP63Cable gland: in polyamide for cables Ø8 mm maximum Fitting: barbed fittings Ø6.2 mm Weight: 1150 gKEY POINTS●1 input for interchangeable probe●1 location for SPI-2 or MVA interchangeable board●Alternating display of 1 to 3 parameters ●3 audible and visual (dual-color LEDs) alarms ●3 analogue outputs (4 wires) 0/5-10 V or 0/4-20 mA●3 reverse relays 3 A/230 Vac●24 Vdc/Vac or 115/230 Vac power supply●Outputs diagnostic●Ethernet communication (optional)●MODBUS network RS485 system (optional)●ABS V0 swivelling housing ●Large display: 50 x 190 mmFEA TURES OF THE HOUSINGTECHNICAL SPECIFICATIONSPART NUMBERSCA310-B : multifunction transmitter, 24 Vac power supplyCA310-H : multifunction transmitter, 115-230 Vac power supplyPower supply24 Vac / Vdc ±10%100-240 Vac, 50-60 HzWarning: risk of electric shockOutput3 x 0/4-20 mA or 3 x 0-5/10 V (4 wires)Common mode voltage <30 VACMaximum load: 500 Ohms (0/4-20 mA) / Minimum load: 1 K Ohms (0-5/10 V)Galvanic isolationOn the outputsDevice fully protected by DOUBLE ISOLATION or REINFORCED ISOLATION Consumption with probe and without option CA310-B: 11 VA CA310-H: 16 VA(CO 2 probe additional consumption for 24 V and 115-230 V models: 2 VA)Relays 3 reverse relays 5 A / 230 Vac Audible alarm Buzzer (70 dB at 10 cm)European directives 2014/30/EU EMC; 2014/35/EU Low Voltage; 2011/65/EU RoHS II; 2012/19/EU WEEE Electrical connectionScrew terminal block for cables from 0.05 to 2.5 mm 2 or de 30 à 14 AWG Carried out according to the code of good practiceRS485 communication (optional)Digital: Modbus RTU protocol, configurable communication speed from 2400 to 115200 BaudsEthernet communication (optional)Ethernet communication module allowing transmission, monitoring and maintenance of transmitters via an Ethernet network in 10 BASE-T and 100 BASE-TX LAN/WAN supporting TCP/IP protocol(additional consumption for 24 V and 115-230 V models: 1 VA)240 mm60.5 mm120 m m25 m mCA 310Large display multifunction transmitterEnvironment and type of fluid Air and neutral gasesConditions of use (°C/%RH/m)From -10 to +50°C. In non-condensing condition. From 0 to 2000 m Storage temperature From -10 to +70°CSecurityProtection class 2; Pollution degree 2; Overvoltage category 2TECHNICAL SPECIFICA TIONSRELA YS AND ALARMSCA310 transmitter has 3 independent and configurable alarms : these are visual and audible alarms and it is possible to couple them with 3 relays.Available settings:●Selection of the parameter (pressure, air velocity, temperature,...)●Time-delays durations from 0 to 600 s ●Alarm action: rising edge, falling edge, monitoring or state of the transmitter ●Operating mode of the relays: negative or positive safety ●Activation of the audible alarm (buzzer), that can be acknowledge by the front keypadCONNECTIONSCable glandsPressure connections(optional)Power supply terminal block (c)LCC-S software connection Solenoid valve Analogue output (a)0/4-20 m A – C u r r e n t0-5/10 V – V o l t a g eG N D – G r o u n d Analogue output 1 (OUT1)G N D – G r o u n d Analogue output 2(OUT2)(a)AutozeroEthernet connection (optional)Type of power supply of the transmitterProbe connection0/4-20 m A – C u r r e n t0-5/10 V – V o l t a g eRS 485 connection (d) (optional)0/4-20 m A – C u r r e n t0-5/10 V – V o l t a g eG N D – G r o u n d Analogue output 3(OUT3)For 24 Vdc/Vac power supply models:For 115 Vac to 230 Vac power supply models:or(c)(c)N e u t r a l (N )~P h a s e (L )~O p e r a t i o n a l g r o u n d i n gN e u t r a l (N ) -P h a s e (L ) +O p e r a t i o n a l g r o u n d i n gSPI-2 board (optional)N O : N o r m a l l y o p e n N C : N o r m a l l y c l o s e dRelay 1C O M : C o m m o n N O : N o r m a l l y o p e n N C : N o r m a l l y c l o s e dRelay 2C O M : C o m m o n (b)A +B-Modbus:123(d)GND N O : N o r m a l l y o p e n N C : N o r m a l l y c l o s e dRelay 3C O M : C o m m o n Relays (b)ELECTRICAL CONNECTIONS – as perNFC15-100 NormThis connection must be made by a formed and qualified technician. Whilst making the connection, the transmitter must not be energized.The presence of a switch or a circuit breaker upstream the device is compulsory.➢0/4-20 mA current output connection:0/4-20 mA Regulator display orPLC/BMS passive type ➢0-5/10 V voltage output connection:➢For 115 Vac to 230 Vac power supply models:+-24 Vdc power supply +-➢For 24 Vdc power supply model:24 Vac power supplyN LLN Pe 230 VacLN Pe 230 Vacor24 Vac power supplyClass IILN LN LN 24 VacLN115/230 Vac power supply0-5/10 VGND-+Regulator display orPLC/BMS passive type-+0/4-20 mA 0-5/10 VGNDL N 24 Vac➢For 24 Vac power supply model:POSSIBLE OPTIONAL MEASUREMENTSThe following probes and boards are available as option for C310 transmitters. For further details please see the technical datasheet of probes for class 310 transmitters.ProbesMeasuring rangesStainless steel or polycarbonate hygrometry / temperature probe From 0 to 100%RH and from -40 to +180°C (according to probe)Air velocity vane probe: air velocity / temperature / airflow From -5 to 35 m/s (according to probe) / From -20 to +80°C / From 0 to 99 999 m³/h Air velocity hotwire probe: air velocity / temperature / airflow From 0 to 30 m/s / From -20 to +80°C / from 0 to 99 999 m³/h Omnidirectional probe: air velocity / temperature From 0 to 5 m/s and from 0 to 50°C Pt100 1/3 DIN temperature probe From -50 to +180°C / From -20 to +80°C CO / temperature probe From 0 to 500 ppm and from 0 to 50°C CO 2 / temperature probeFrom 0 to 20 000 ppm and from 0 to 50°CBoardsMeasuring rangesPressure / atmospheric pressure From -100 à +10 000 Pa (according to boards) / from 800 to 1100 hPaCurrent / voltage3 current/voltage analogue inputs : 0-20 mA / 4-20 mA and 0-2,5 V / 0-5 V / 0-10 V, with terminal blockF T a n g – C A 310 – 27/01/2017 – R C S (24) P ér i g u e u x 349 282 095 N o n -c o n t r a c t u a l d o c u m e n t – W e r e s e r v e t h e r i g h t t o m o d i f y t h e c h a r a c t e r i s t i c s o f o u r p r o d u c t s w i t h o u t p r i o r n o t i c e .MOUNTINGInstall the mounting bracket in horizontal position along a plane wall (see below dimensions / drilling drawing).Put the display inside the mounting bracket, with the 2 screws. Remove the screw covers located on the right and left side of housing, in order to have access to the 4 shutting screws.Make the electrical connection with the connection glands, with soft cable Ø7 mm maximum. Close the housing before powering on.MAINTENANCEOPTIONS●LCC-S: configuration software with USB cable●SQR/3 function: square root extraction function for the calculation of air velocity and airflow ●RS5: RS 485 Protocol Modbus digital output ●CETHE: Ethernet board ●HRP: high resolution (example in pressure: 0.1 Pa) with SPI2-100 board ●Calibration certificateCALIBRA TIONOutputs diagnostics: with this function, you can check with a multimeter (or on a regulator/display, or on a PLC/BMS) if the transmitter outputs work properly. The transmitter generates a voltage of 0 V, 5 V and 10 V or a current of 0 mA, 4 mA, 12 mA and 20 mACertificate: transmitters are supplied with an individual adjusting certificate and can be supplied with a calibration certificate as an option.CONFIGURA TION19m m5mm32m m46.5mm240 mmint.150 mm 46.5mm48.5m mClass 310 transmitters allows you to set all the parameters managed by the transmitter: units, measuring ranges, alarms, outputs, channels... via the different methods shown below:➢Via keypad, only on models with display. A code-locking system for keypad guarantees the security of the installation. See configuration manual.➢Via software (optional): simple and user-friendly. See LCC-S user manual.➢Via Modbus (optional): configuration of all parameters from your PC, via the supervision or data acquisition software.➢Via Ethernet (optional): configuration of all parameters from your PC, via the supervision or data acquisition software.Only the accessories supplied with the device must be used.PRECAUTIONS FOR USEPlease always use the device in accordance with its intended use and within parameters described in the technical features in order not to compromise the protection ensured by the device.RS 485 MODBUS PROTOCOL (optional)Class 310 transmitters can be linked in one network operating on a RS485 home bus.The RS 485 digital communication is a 2-wire network, on which the transmitters are connected in parallel. They are connected to a PLC/BMS via the RTU Modbus communication system. Since the C310 can be configured with the keypad, the MODBUS enables remote configuration, to measure 1 or 2 parameters or to see the status of the alarms...ETHERNET BOARD (optional)An Ethernet board can put put on a CA310 transmitter allowing for each transmitter to have a specific configurable IP address. So the user can remotely interrogate the transmitter, retrieve data, modify the configuration, ...It is also possible to integrate CA310 transmitters into a computer network via the RJ45 connection located at the bottom of the transmitter.Avoid aggressive solvents. When cleaning rooms or ducts with products containing formol, protect the the transmitter.Once returned to KIMO, required waste collection will be assured in the respect of the environment in accordance with European guidelines relating to WEEE.。

罗斯蒙特 C 310 多功能变送器 操作手册说明书

罗斯蒙特 C 310 多功能变送器 操作手册说明书

差压 / 风速 / 风量 / 湿度 / 温度 /大气压 / CO / CO2操作手册C 310多功能变送器0 / 4 ~ 20 m A - 电流输出信号接线端口 (a)电源供应 (c)电缆接入电源种类(a)模拟输出 (1)0 ~ 5 / 10 V - 电压G N D - 接地差压自动校准元件压力连接端口智能型探头连接端口差压或大气压模块差压手动零点校准以太网通讯模块总线通讯RS 485 (d)继电器 (b)N OC O MN C(b)继电器 (1)N OC O MN C继电器 (4)N OC O MN C继电器 (3)N OC O MN C继电器 (2)0 / 4 ~ 20 m A - 电流模拟输出 (4)0 ~ 5 / 10 V - 电压G N D - 接地0 / 4 ~ 20 m A- 电流模拟输出 (3)0 ~ 5 / 10 V- 电压G N D - 接地0 / 4 ~ 20 m A - 电流模拟输出 (2)0 ~ 5 / 10 V - 电压G N D - 接地(c)用于电源供应相位 中性 (c)用于电源供应相位 中性 (d)Modbus RS-485ABC 310 接线图电气接线 - 符合 NFC15-100 标准接线应由合格技术人员操作。

当接线时, 变送器必须停止供应电源。

➢电流输出信号 0 / 4 ~ 20 mA 接线方式:➢电源供应 24 Vdc 接线方式:➢电源供应 24 Vac 接线方式:➢电源供应 230 Vdc 接线方式:电源供应 24 Vac Class II显示仪 或 PLC / BMS主动种类+-24 Vdc电源供应+-N LLN Pe 230 VacLN Pe 230 Vac或LN LN LN 24 VacLN 230 Vac电源供应GND-+显示仪 或 PLC / BMS主动种类-+GNDL N 24 Vac电源供应 24 Vac Class II➢电压输出信号 0 ~ 5 / 10 V 接线方式:内容目录1. 产品介绍 (5)1.1 变送器介绍 (5)1.2 按键介绍 (5)1.3 温湿度传感器保护盖 (6)2. Modbus 通讯 (7)2.1 设置参数 (7)2.2 功能 (7)2.3 寄存器读取码 (7)3. 设置变送器 (12)3.1 输入安全码 (12)3.2 设置变送器的参数 (12)3.2.1 设置显示屏 (13)3.2.2 设置曲线图时段 (13)3.2.3 设置语言 (13)3.2.4 设置日期和时间 (13)3.2.5 开启/关闭按键音 (13)3.2.6 锁定或开启按键 (13)3.2.7 修改安全码 (14)3.2.8 恢复出厂设置 (14)3.2.9 设置Modbus通讯 (适用于已订购此功能) (14)3.2.10 设置以太网通讯 (适用于已订购此功能) (14)3.2.11 访问变送器信息 (15)3.3 设置测量通道 (15)3.4 设置模拟信号输出 (15)3.4.1 选择模拟信号输出类型 (15)3.4.2 设置模拟信号输出对应量程 (16)3.4.3 输出信号自诊断 (16)3.5 设置报警 (17)3.5.1 选择报警模式 (17)3.5.2 设置上升或下降报警模式 (18)3.5.3 设置监测报警模式 (18)3.5.4 设置变送器状态报警模式 (19)3.5.5 设置继电器 (适用于已订购此功能) (19)3.6 设置探头, 模块和标准参数 (20)3.6.1 设置风速和风量探头 (20)3.6.2 设置二氧化碳或温湿度探头 (21)3.6.3 设置模块 (21)3.7 开启其他选购功能 (24)4. 功能描述和 Modbus 通讯连接 (26)4.1 变送器 (26)4.2 测量通道 (27)4.3 输出信号 (27)4.4 报警和继电器 (28)4.4.1 报警 (28)4.4.2 继电器 (29)4.5 测量参数 (29)4.6 差压模块和探头 1 和 2 参数 (30)4.6.1 差压模块参数 (30)4.6.2 探头 1 参数 (31)4.6.3 探头 2 参数 (31)4.6.4 标准参数 (32)1. 产品介绍1.1变送器介绍C310 变送器含显示屏型号可通过按键进行设置。

他励直流电动机实验-全文可读

他励直流电动机实验-全文可读

Ia不 大 于 0 . 5
T
实验内容—他励直流电动机的机械特性
一 、固有机械特性 1. 励磁电流调至100mA左右 2. 电枢电压调至约最小 ,开始起动电机 3. 电枢回路调节电阻最小R=0 4. 电枢电压调至约200V 5. 调节测功机转矩设置钮(小 →大),不要超过
额定值( 电枢电流不超过0.55A) 6. 观察记录电机转速 、转矩或电枢电流 、 电压的
电源+
A
励磁
电源-
Rf
励磁调节电阻
电源+
A
电枢
Ra



电源-
节 电

测功机的使用
1. 置于转矩控制状态 2. 转速设定旋钮: 最大 3. 转矩设定旋钮: 最小 4. 注意转矩调零点
直流他励电动机的起动准备
• 在关闭电源前提下 , 按图接线 , 指导教师 检查。
• 所有旋钮应缓慢轻旋 , 到位后不许强行硬 扭。
额定值( 电枢电流不超过0.55A) 6. 观察记录电机转速 、转矩或电枢电流 、 电压的
变化 ,至少测量3-5个点( Ia=0. 1 、0.2 、0.3、 0.4 、0.5A) 。
实验内容—他励直流电动机的机械特性
二 、人为机械特性— 电枢串电阻 1. 励磁电流调至100mA左右
2. 电枢回路调节至2/3位置(R=60Ω)
• 励磁变阻器在最小位置。 • 电枢变阻器在最大位置。
• 先开励磁绕组开关 , 后开电枢绕组开关。 • 先关电枢绕组开关 , 后关励磁绕组开关。
固有特性 、串电阻特性
n
R=0 (固有) R=30( 串电阻) R=60( 串电阻)
T Ia不 大 于 0 . 5

大西洋水景L-305 L-310系列泵操作手册说明书

大西洋水景L-305 L-310系列泵操作手册说明书
To avoid an accident do not use the pump in any way other than as described in this manual. Please note the manufacturer cannot be responsible for accidents arising because the product was not used as prescribed. After reading this manual keep it as a reference in case questions arise during use. Using the pump in a manner that is not prescribed will void the warranty.
Operating Manual
Includes Pumps: L-305 L-310
1.330.274.8317 www.ATLAN TI CWAT E R G AR DE N
Introduction
Thank you for selecting the TidalWave L-305/L-310 series pumps. Before using this pump please take a moment to review this manual.
• Always operate the pump completely submerged in water. • Avoid dry operation, which will not only lower performance but can
cause the pump to overheat/malfunction, leading to electrical leakage, shock or premature failure.

310水冷螺杆机操作说明书

310水冷螺杆机操作说明书

目录一、机组规格 (1)二、机器概述 (2)三、机组组成及特点 (3)四、搬运、安装及注意事项 (8)五、机组的电气连接 (11)六、操作说明 (12)七、操作、保养与维修 (20)八、常见故障分析 (22)九、注意事项 (23)十、电路图(附图1)十一、系统安装图(副图2)十二、运行记录表(副表1)一、机组规格:备注:1、本机组制冷工况为:冰水进水温度12℃,出水7℃,冷却进水30℃,冷却出水35℃;2、本系列机组采用可编程序PLC控制器控制,触摸屏人机界面操作;3、电源制式:3P-380V-50Hz。

允许电压波动±10%;允许相同电压差±2%;二、机器概述水冷螺杆式冷水机组是我公司最早研制和开发的产品,其制冷量从30.3~2015.6KW。

该系列机组综合了其它产品的特点,采用进口半密闭螺杆压缩机,辅之以高效率的换热器,通过I/O控制器的控制,使机组具有外形紧凑,布局合理,使用维护方便等特点,用户只要连接水系统的管路和要求的供电电源,即可投入运行。

因此,凯利水冷式冷水机组在商业上适用于别墅、豪宅、多居室套房、中小型办公室、分层管理的大厦空调系统以及酒楼、车间﹑商店等空调环境;在工业上广泛用于塑料﹑电子﹑化工﹑冶金﹑食品﹑制药﹑电镀﹑皮革﹑工艺﹑科研等。

三、机组组成及特点1、机组控制器、操作器本系统采用先进的、高集成度的一体化单片机,极大提高了系统抗干扰能力。

外型采用塑料外壳,安装方便。

前后板通过485通讯方式进行数据连接,整个系统可以一体化安装,也可以进行分体式安装。

操作器是LED文本显示,通过软键操作,操作方便和简单。

控制板外形图如图3-2、显示屏外形如图3-3所示。

图3-1 I/O控制板图3-2 显示屏操作器2、压缩机压缩机是采用进口的半密闭螺杆压缩机,螺杆压缩机由一对平行、互相啮合的阴、阳螺杆构成,是回转压缩机中应用最广泛的一种。

具有低噪音、低振动、高效率和高耐久性特点。

Omega OS310-Series 高性能红外温度计说明书

Omega OS310-Series 高性能红外温度计说明书

U ser’Shop onlineate-mail:**************For latest productmanuals:OS310-SeriesHigh Performance Infrared Thermometer **************Servicing North America:Omega Engineering, Inc.800 Connecticut Ave. Suite 5N01, Norwalk, CT 06854 Toll-Free: 1-800-826-6342 (USA & Canada only)Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) U.S.A.Headquarters:Tel: (203) 359-1660 e-mail:**************Fax: (203) 359-7700 The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice.Table of Contents ................................................................................................... Error! Bookmark not defined.1)Introduction .................................................................................................... Error! Bookmark not defined.1.1How it works .......................................................................................................... E rror! Bookmark not defined.1.2Caution .................................................................................................................. E rror! Bookmark not defined.2)Specifications .................................................................................................. Error! Bookmark not defined.3)Operating Instructions ..................................................................................... Error! Bookmark not defined.3.1Battery Installation: ........................................................................................... E rror! Bookmark not defined.3.1.1 Changing Units (6)3.1.2 Back Lighting (6)3.1.3 Adjusting Laser (6)3.1.4 Adjusting Temperature Assistant (6)3.1.5 Changing Emissivity and Alarm Values (6)3.2LCD Display: (7)3.3Locating a Hotspot: (7)3.4Keypad and components: (7)4)Maintenance ................................................................................................... Error! Bookmark not defined.graphite, etc. in temperature ranges between -50°C (-58 °F) and 1650°C (3002°F). This portable battery powered unit displays current temperature as well as minimum, maximum, average and differential temperatures. Other features include an adjustable emissivity, alarm settings and a single laser dot to help locate the target.1.1How it worksThe sensor determines temperature by focusing the infrared energy that is radiated from an object. The focused energy is converted into an electrical signal proportional to the energy emitted.A clean line of sight free of dust or mist is needed between the sensor and the object.For increased ease and accuracy, the laser pointer makes aiming even more precise. Measurement:When taking measurement, point thermometer toward the object to be measured and hold the trigger. The object under test should be larger than the spot size calculated by the field of view diagram below.Field of View:Field of view, or distance to spot ratio, is the size of an area that can be measured from a specified distance. As the distance from the object increases, the spot size of the measuring area becomes larger. Make sure the target is larger than the unit’s spot size. When accuracy is critical, make sure the target is at least twice as large as the spot size. Please see field of view diagram for the OS310-Series below.Emissivity:Most organic materials and painted or oxidized surfaces have an emissivity of 0.95. Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate adjust the emissivity setting to match the material using the emissivity table. Another option is to set the emissivity to 0.95 and cover the measured surface with masking tape or flat black paint. Then measure the tape or painted surface when it reaches the material temperature.Emissivity Table:41.2 CautionInfrared thermometer should be protected for the following:- EMF (electro-magnetic fields) from arc welders and induction heaters.- Thermal shock (caused by large or abrupt ambient temperature changes allow 30 minutes for unit to stabilizebefore use).- Do not leave the unit on or near objects of high temperature.Warning: Do not point laser directly at eye or indirectly off reflective surfaces!5Temperature Range -50 to 1650°C (-58 to 3002°F)Accuracy ±1.5% rdg or ±1.5°C (2.7°F), whichever is better Field of View 50:1Resolution 0.1°C or 0.1°F Response Time <250 ms Spectral Response 8 – 14 µmEmissivityAdjustable 0.10 to 1.00 Operating Temperature 0 - 40°C (32 - 104°F)Weight 270 g (9.5 oz) including batteryDimensions 141 x 200 x 60 mm (5.6 x 7.9 x 2.4”) Power9V Battery (included)Relative Humidity10% to 95% non-condensing3.1Battery Installation and Basic OperationLocate the notches on the side of the unit’s handle and pull the front of the handle forwards as shown below (1,2). Attach a 9V battery (provided) to the black connector inside, be sure to connect the positive and negative sides to the corresponding terminals (3). Swing the front of the handle back upwards to close the unit (4).1 2 3 4Pull the trigger and LCD display will turn on and display reading. Release the trigger to hold last measured temperature reading. The display will shut off after 30 seconds of inactivity.3.1.1Changing units1)Press the C/F key to toggle between Celsius and Fahrenheit3.1.2Back lighting1) Press back light key to toggle the back light on and off3.1.3Adjusting Laser1) Press laser key to toggle the laser dot on and off3.1.4Adjusting the temperature assistant1)Press MODE key to scroll through Minimum, Maximum, Average and Differential temperaturesas well as Low Alarm and High Alarm values.3.1.5Changing Emissivity and Alarm values1)Press and hold MODE key for 3 seconds to change emissivity and alarm values2)Press the MODE key once to change emissivity, twice to change the low alarm valueand three key presses to change the high alarm value3)Press the ▲key to increase the value and ▼key to decrease the value4)Press the MODE key to store the new value5)Press and hold the MODE key for 3 seconds to return63.2LCD Display3.3Locating a HotspotTo find a hot spot aim the thermometer outside the area of interest, then scan across with up and down motions until you locate the hot spot. (turn on the laser for accurate measuring)3.4Keypad and components(1) Trigger(2) Back light key(3) Mode key(4) Laser light key(5) Function keys(6) Celsius / Fahrenheit key(7) Display(8) Laser(9) Model Identification(10) Battery CoverGently brush remaining debris away with a moist cotton cloth.2)Case cleaning: clean the case with a damp sponge/cloth and mild soap.Note: Do not use solvent to clean lens and do not submerge the unit into water or any other liquid 7WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a p eriod of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; o r current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products. However, O MEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY A ND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OFLIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of O MEGA with respect to this order, whether based on contract, warranty, negligence, i ndemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify O MEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.FOR WARRANTY RETURNS, please have the following information available BEFORE contacting O MEGA: FOR NON-WARRANTY REPAIRS, consultOMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:1. Purchase Order number to cover the COST o f the repair,2. Model and serial number of the product, and3. Repair instructions and/or specific problems relative to the product.1. Purchase Order number under which the product w as PURCHASED,Model and serial number of the product under warranty, andRepair instructions and/or specific problems relative to the product.2. 3. OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords o ur customers the latest in technology and engineering.OMEGA is a trademark of OMEGA ENGINEERING, INC.© Copyright 2019 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.Where Do I Find Everything I Need for Process Measurement and Control?OMEGA…Of Course!Shop online at TEMPERATUREThermocouple,RTD&Thermistor Probes,Connectors,Panels&AssembliesWire:Thermocouple,RTD&ThermistorCalibrators&Ice Point ReferencesRecorders,Controllers&Process MonitorsInfrared PyrometersPRESSURE, STRAIN AND FORCETransducers&Strain GagesLoad Cells&Pressure GagesDisplacement TransducersInstrumentation&AccessoriesFLOW/LEVELRotameters,Gas Mass Flowmeters&Flow ComputersAir Velocity IndicatorsTurbine/Paddlewheel SystemsTotalizers&Batch ControllerspH/CONDUCTIVITYpH Electrodes,Testers&AccessoriesBenchtop/Laboratory MetersControllers,Calibrators,Simulators&PumpsIndustrial pH&Conductivity EquipmentDATA ACQUISITIONCommunications-Based Acquisition SystemsData Logging SystemsWireless Sensors,Transmitters,&ReceiversSignal ConditionersData Acquisition SoftwareHEATERSHeating CableCartridge&Strip HeatersImmersion&Band HeatersFlexible HeatersLaboratory HeatersENVIRONMENTAL MONITORINGAND CONTROLMetering&Control InstrumentationRefractometersPumps&TubingAir,Soil&Water MonitorsIndustrial Water&Wastewater TreatmentpH,Conductivity&Dissolved Oxygen InstrumentsUNRESTRICTED。

CX310 立体声双向 单向三路活动分隔过滤器用户指南说明书

CX310 立体声双向 单向三路活动分隔过滤器用户指南说明书

CX310Stereo 2-Way / Mono 3-Way Active CrossoverUSER'S GUIDEIMPORTANT SAFETY INSTRUCTIONS – READ FIRSTThis symbol, wherever it appears, This symbol, wherever it appears, alerts youalerts you to the presence of uninsulated to important operating and maintenancedangerous voltages inside the enclosure that instructions in the accompanying literature.may be sufficient to constitute a risk of shock. Please read the manual.Read instructionsRetain these safety and operating instructions for future reference. Heed all warnings printed here and on the equipment. Follow the operating instructions printed in this user guide.Do not openThere are no user serviceable parts inside. Refer any service work to qualified technical personnel only.Power sourcesOnly connect the unit to mains power of the type described in this user guide or marked on the rear panel. The power source must provide a good ground connection.Power cordUse the power cord with sealed mains plug appropriate for your local main supply as provided with the equipment. If the provided plug does not fit into you outlet consult your service agent. Route the power cord so that it is not likely to be walked on, stretched or pinched by items placed upon or against.GroundingDo not defeat the grounding and polarization means of the power cord plug. Do not remove or tamper with the ground connection on the power cord.MoistureTo reduce the risk of fire or electrical shock, do not expose the unit to rain, moisture or use in damp or wet conditions. Do not place container of liquid on it, which may spill into any openingsHeatDo not locate the unit in a place close to excessive heat or direct sunlight, as this could be a fire hazard. Locate the unit away from any equipment, which produces heat such as: power supplies, power amplifiers and heaters.EnvironmentProtect from excessive dirt, dust, heat, and vibration when operating and storing. Avoid tobacco ash, drink spillage and smoke especially that associated with smoke machines.HandlingProtect the controls from damage during transit. Use adequate padding if you need to ship the unit. To avoid injury to yourself or damage to the equipment take care when lifting, moving or carrying the unit.ServicingSwitch off the equipment and unplug the power cord immediately if it is exposed to moisture, spilled liquid or the power cord or plug becomes damaged during a lightning storm or if smoke odor or noise is noted. Refer servicing to qualified technical personnel only.InstallationInstall the unit in accordance with the instruction printed in the user guide.IMPORTANT SAFETY INSTRUCTIONS – READ FIRST (2)OVERVIEW (4)Features (4)INSTALLATION (5)AC Power Hookup (5)Input/Output Connections (5)Mono 3-Way Configuration (5)Connections: (5)Controls: (5)OPERATION (6)FRONT PANEL CONTROLS (6)Power Switch (6)Clip Indicators (6)Input Level Controls (6)Mute Switches (6)Low And High Output Level Controls (6)Crossover Frequency Controls And Range Switches (7)REAR PANEL CONNECTORS and CONTROLS (7)XLR Jacks (7)1/4” Phone Jacks (7)Mono/Stereo Mode Switch (7)APPLICATIONS (8)Typical Setup (8)Signal Flow (8)Initial Setup Tips (8)WARRANTY INFORMATION (9)Limited Warranty (9)Exclusions ....................................................................................................... Error! Bookmark not defined. SERVICE . (10)SPECIFICATIONS (11)OVERVIEWThe ART CX310 Stereo 2-Way/ Mono 3-Way Active Crossover is a perfect addition to any sound reinforcement system. Designed for PA and fixed-installation applications, the CX310 employs 24dB/ octave state-variable, fourth-order, Linkwitz-Riley filters. These filters guarantee in-phase outputs at all frequencies. This ensures the proper acoustic summing of common signals from adjacent drivers in the crossover region.The CX310 may be used as either a stereo 2-way crossover network, splitting the signal in each channel into two separate frequency ranges (Lo and Hi), or as a mono 3-way crossover network, splitting one signal into three separate frequency ranges (Lo, Mid and Hi).Each channel features input level, high and low output level and crossover frequency rotary controls.A frequency x10 switch is provided for varying the crossover frequency from the standard 80Hz - 920Hz to 800Hz - 9200Hz. Front-panel output mute switches are provided for each individual output to ease system setup. The rear panel features balanced XLR and 1/4” TRS input and output connectors as well as a 2-way/ 3-way mode selector switch. Power for the CX310 is internal.The ART CX310 Stereo 2-Way/ Mono 3-Way Active Crossover has the features and performance you need for any audio application requiring a crossover. Housed in a rugged all-steel chassis, the model CX310 will provide years of reliable and continuous service.Features• Stereo 2-way or mono 3-way configurations• Fourth-order Linkwitz-Riley filters• Balanced XLR and 1/4" TRS input and output connectors• Adjustable crossover frequency range (80Hz to 920Hz or 800Hz to 9.2kHz)• Independent output level control for each output• Individual output muting switches• Clipping indicators on all outputs• Rugged, fully shielded all-steel chassis• Internal AC power supply• Three year warrantyINSTALLATIONThe ART CX310 may be used in a wide variety of applications and environments. Enclosed in a 1U (1.75 inches high) rack-mountable, all-steel enclosure, the unit is designed for continuous professional use. The depth is 6.5 inches, exclusive of the power cord. Mounting location is not critical. However, for greater reliability, we recommend that you not place the unit on top of power amps or other sources of heat.AC POWER HOOKUPThe CX310 has an internal power supply designed to operate from 105 to 120VAC at 50/60Hz. Export units are configured with a different power cord and the voltage switch is set for the country of destination. Before plugging the CX310 into the AC mains, make sure that all of the equipment following the crossover outputs are turned off or that all of the outputs are turned down.INPUT/OUTPUT CONNECTIONSThe CX310 has XLR and 1/4" TRS phone jack connectors for each input and output. All connections are active balanced although the 1/4" phone jack connections can easily be converted to unbalanced operation by using two-conductor phone plugs. Inserting a plug into a 1/4" jack disconnects the associated XLR connector.MONO 3-WAY CONFIGURATIONThis information is intended to clarify how the CX310 is used in the mono 3-way configuration.Connections:Input Channel One INPUT(Channel Two INPUT not used)Low Output Channel One LOW OUTPUTMid Output Channel Two LOW OUTPUTHigh Output Channel Two HIGH OUTPUT(Channel One HIGH OUTPUT not used)Controls:Input Level Channel One INPUT LEVEL controlLow Output Mute Channel One LOW MUTE switchLow Output Level Channel One LOW OUTPUT LEVEL controlLow/Mid Crossover Channel One RANGE switch and FREQUENCY control(Channel One HIGH MUTE switch andHIGH OUTPUT LEVEL control not used)(Channel Two INPUT LEVEL control not used)Mid Output Mute Channel Two LOW MUTE switchMid Output Level Channel Two LOW OUTPUT LEVEL controlMid/High Crossover Channel Two RANGE switch and FREQUENCY controlHigh Output Mute Channel Two HIGH MUTE switchHigh Output Level Channel Two HIGH OUTPUT LEVEL controlOPERATIONFRONT PANEL CONTROLSPOWER SWITCHThe POWER switch applies and removes power to the unit. Make sure that all equipment after the CX310 is either off or the outputs are turned all the way down before turning the CX310 on or off. CLIP INDICATORSSeparate HIGH and LOW CLIP indicators are provided for each channel of the CX310. These indicators will light at approximately 3dB before clipping occurs in any stage of the channel. To prevent overloading the channel, either turn down the CX310 input control or turn down the output level of the piece of equipment feeding the CX310 (i.e. mixer, equalizer or other piece of processing equipment.).INPUT LEVEL CONTROLSAn INPUT LEVEL control is provided on each channel of the CX310. If you are using the CX310 as a mono 3-way crossover, the Channel One INPUT CONTROL is the only one used. The INPUT LEVEL control should be set at its 0 marking in most cases. Increasing or decreasing gain should only be done to make up for deficiencies in other parts of the system.MUTE SWITCHESMUTE switches are provided for each output on the CX310. These are intended for use when setting up your system and testing either the crossover frequency point or the separate amplifiers and speakers they are feeding. These switches allow you to isolate a specific frequency output on a specific channel for fine-tuning or troubleshooting. It is not recommended that you mute or un-mute any frequency band during normal usage. Levels should be turned down when the MUTE switches are activated or de-activated.LOW AND HIGH OUTPUT LEVEL CONTROLSEach channel of the CX310 has LOW and HIGH OUTPUT LEVEL controls. These controls are used to trim the output levels to the LOW and HIGH OUTPUT jacks on the rear of the unit, respectively. If you are using the CX310 as a mono 3-way crossover, the Channel One LOW OUTPUT LEVEL control sets the level of the LOW OUTPUT, the Channel Two LOW OUTPUT LEVEL control sets the level of the MID OUTPUT, and the Channel Two HIGH OUTPUT LEVEL control sets the level of the HIGH OUTPUT.These controls attenuate only (there is no gain). In most cases you would set them to 0 (fully clockwise). You can use these controls to prevent overdriving the inputs of your amplifiers or to compensate for variations in amplifier gain or speaker efficiency. Additionally, you can use these controls to balance the level between highs and lows in your system.CROSSOVER FREQUENCY CONTROLS and RANGE SWITCHESEach channel of the CX310 has a crossover FREQUENCY control and RANGE switch to set the crossover point for the high and low frequencies. These controls cover the frequency range of 80Hz - 920Hz, with the RANGE switch in the out position (x1), or 800Hz to 9.2kHz, with the RANGE switch in the in position (x10). All frequencies below the set frequency will be sent to the LOW OUTPUT and all frequencies above will be sent to the HIGH OUTPUT.When the CX310 is used as a stereo 2-way crossover, both RANGE switches will most commonly be used in the out position (80Hz-920Hz). When used as a mono 3-way crossover, the Channel One FREQUENCY control is used to set the Low/Mid frequency point and the Channel Two FREQUENCY control is used to set the Mid/High frequency point. In this case, the Channel One RANGE switch will most commonly be used in the out position (80Hz-920Hz), while the Channel Two RANGE switch will most commonly be used in the in position (800Hz-9.2kHz).The crossover filters are 4-pole Linkwitz-Riley designs (24dB/octave). This yields a sharp roll off to help protect speakers and the outputs sum to a flat response.NOTE:Never change the frequency range switches (from x1 to x10 position - or vice versa) with the crossover passing audio signals. This may produce transients that can damage speakers.REAR PANEL CONNECTORS and CONTROLSIt is easy to interface the unit with a wide variety of equipment. The rear panel has balanced XLR and 1/4” phone jack connectors.XLR JACKSThe XLR connections are balanced and follow the AES standard for wiring: Pin 1 = Ground, Pin 2 = Hot (+) and Pin 3 = Cold (-). These connectors directly parallel the associated 1/4” connectors.1/4” PHONE JACKSThe 1/4” connections are balanced with Tip = Hot (+), Ring = Cold (-), and Sleeve = Ground. A two-conductor (tip and sleeve) shorts the Cold (-) and Ground connections together to convert to unbalanced operation. Inserting a plug into a 1/4" jack disconnects the associated XLR connector.MONO/STEREO MODE SWITCHThis switch configures the CX310 for stereo 2-way operation with the switch in the out position or for mono 3-way operation with the switch in the in position.APPLICATIONSThe following guidelines refer to a P.A. system, but the same basic ideas apply to a home recording setup or a Hi-Fi system.Typical SetupFor a stereo 2-way system, separate high frequency (horn or tweeter) and low frequency (bass or subwoofer) speaker cabinets are used for each channel (left and right) of the stereo sound system and are driven by their own power amplifiers. For a mono 3-way system, separate high frequency (horn or tweeter), mid frequency (mid or full range) and low frequency (bass or subwoofer) cabinets are used for each channel of the sound system.The crossover is used to split each channel's signal into two or three frequency bands, which feed separate amplifiers. This delivers the proper frequencies to each speaker cabinet as well as allowing its associated amplifier to produce acoustic power more efficiently.Note: You will need two 310 crossovers if your three-way system is stereo.It is very important that you use caution when selecting the crossover points for any system. Refer to the documentation that came with your speaker cabinets for information on their proper frequency ranges. This is especially important for high frequency horns; damage may occur from sending lower frequencies than specified into the drivers!Signal FlowIn most situations, the crossover is the last piece of equipment in the signal chain before the power amplifiers. Signal flow is as follows:Mixer → Equalizer → Crossover → Power Amplifier → Speaker CabinetsSometimes a limiter is placed between the mixer outputs and the equalizer or after the equalizer for system protection.Initial Setup Tips1. Set all level controls to their full counter-clockwise position.2. Connect the output(s) of your mixer (or equalizer) to the input(s) of the CX310. If stereo,Channel One is left.3. Connect the LOW OUTPUT of each channel (LOW OUTPUT of Channel One for mono3-way configuration) to the power amplifier powering the low frequency cabinet(s).4. If set for mono 3-way, connect the MID output (LOW OUTPUT of Channel Two) to thepower amplifier powering the mid frequency cabinet.5. Connect the HIGH OUTPUT of each channel (HIGH OUTPUT of Channel Two for mono3-way configuration) to the power amplifier powering the high frequency cabinet(s).6. Set the crossover frequency for each channel (they should be the same if your PAcabinets are the same) or each frequency band for mono 3-way configuration.7. With the power amplifier volume controls turned all the way down, turn on all equipment inthe system.8. With a program source running through the system, turn up the power amplifier volumecontrols and slowly turn up the crossover input level controls while checking for clipping.9. Turn up each of the crossover's output level controls while checking each individual outputfor sound and performance.WARRANTY INFORMATIONLimited WarrantyApplied Research and Technology will provide warranty and service for this unit in accordance with the following warrants:Applied Research and Technology, (ART) warrants to the original purchaser that this product and the components thereof will be free from defects in workmanship and materials for a period of three years from the date of purchase. Applied Research and Technology will, without charge, repair or replace, at its option, defective product or component parts upon prepaid delivery to the factory service department or authorized service center, accompanied by proof of purchase date in the form of a valid sales receipt.This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs. This warranty is void if the serial number is altered, defaced, or removed.ART reserves the right to make changes in design or make additions to or improvements upon this product without any obligation to install the same on products previously manufactured.ART shall not be liable for any consequential damages, including without limitation damages resulting from loss of use. Some states do not allow limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific rights and you may have other rights, which vary, from state to state.For units purchased outside the United States, an authorized distributor of Applied Research and Technology will provide service.SERVICEThe following information is provided in the unlikely event that your unit requires service.1. Be sure that the unit is the cause of the problem. Check to make sure that the unit has powersupplied, that all cables are connected correctly, and that the cables themselves are in working condition. You may want to consult with your dealer for assistance in troubleshooting or testing your particular configuration.2. If you believe that the ART unit is at fault, go to . You may contact CustomerService for more assistance, or directly request a Return Authorization for service in the“resources” area of the website.3. If you are returning the unit for service, pack the unit in its original carton or a reasonablesubstitute. The original packaging may not be suitable as a shipping carton, so consider putting the packaged unit in another box for shipping. Print the RA number clearly on the outside of the shipping box. Print your return shipping address on the outside of the box.4. Include with your unit: a note with the RA number and your contact information, including a returnshipping address (we cannot ship to a P.O. box) and a daytime phone number, and a description of the problem, preferably attached to the top of the unit. Also include a copy of your purchase receipt.Fill in the following information for your reference:Date of purchase ___________________Purchased from ___________________Serial Number ___________________SPECIFICATIONSInput Connections XLR, 1/4” TRS, balancedOutput Connections XLR, 1/4” TRS, balancedFrequency Response 10Hz to 20kHz, +0/-1.5dBCrossover Frequency Rangex1 80Hz to 920Hzx10 800Hz to 9.2kHzCrossover Filter Type Fourth-order Linkwitz-Riley, 24dB/octaveDynamic Range 118dBSignal to Noise Ratio >85dBInput Impedance 20k OhmsOutput Impedance 150 OhmsMaximum Input Level +13dBuMaximum Output Level +21dBuTotal Harmonic Distortion (THD) <0.05% (20Hz-20kHz)Maximum Gain +4dBPower Requirements 105-120V AC, 50-60hz, 3VA (USA)Export units configured for country of destination Dimensions (HWD) 1.75” x 19” x 6.5”44mm x 483mm x 165mmWeight 7.1 lbs. (3.2 kg)ART maintains a policy of constant product improvement. ART reserves the right to make changes in design or make additions or improvements to this product without any obligation to install these changes on products previously manufactured. Therefore, specifications are subject to change without notice.E-mail:***********************© 2010 Applied Research & TechnologyCX310V1.1。

DeLonghi coffee machine 说明书

DeLonghi coffee machine 说明书

INDIA DELONGHI DISTRIBUTOR/DEALERwww.brandpeople.co.inTraditional PumpEC 860.M Distinta ECI 341.BK Distinta ECI 341.BZ Distinta ECI 341.CPIcona Vintage ECOV 311.BG Icona Vintage ECOV 311.GRIcona Vintage ECOV 311.BK Icona ECO 311.R ECP 33.21ECP 35.31(Malaysia only)(Malaysia only)Dedica Style EC 685.M Dedica Style EC 685.R Dedica StyleEC 685.W PrimaDonna Elite Experience ECAM 650.85.MSPrimaDonna Elite ECAM 650.75.MS ElettaECAM 45.760.W Dinamica ECAM 350.75.S Magnifica S ECAM 22.110.SBAutentica ETAM 29.660.SB Cappuccino ECAM 23.460.S Dinamica ECAM 350.15.B www.brandpeople.co.inwww.brandpeople.co.inINDIA DELONGHI DISTRIBUTOR/DEALERONE TOUCH DIRECT DRINKSCappuccino Mixmilk coffee.Hot MilkWhite hot milk with the desired level offoam.CaffelatteSingle espresso shot mixed with 3 times quantity of hot milk topped with a thin layerof foam.Espressorecipe.Doppio+Made with an extra quantity of coffee and a deep pre-infusion for extra aroma and energy.Coffeeof foam.Latte macchiato Single espresso shot with hot milk topped with medium level of foam.Cappuccino+Creamy cappuccino made with a shot ofdoppio+.Flat WhiteSingle espresso shot mixed with 2 times the quantity of hot milk topped with velvetyfoam.Green TeaEnjoy Japanese green teas at its ideal White TeaMild and sweet flavor temperature any time.that is velvet-like insmoothness.ChocolateMade by a dedicated special carafe ,adding powdered Cold CoffeeWhen it’s too chocolate to milk.warm for hot coffee,go for a homemadecold brew!Espresso MacchiatoSingle espresso shot with a dash of hot milk topped OolongExtract complex with foam.flavours of tea to the fullest.Cold MilkProvides a great solution to beat hunger pangs in Cold Milk FoamCold milk topped between meals.with rich creamy foamLong-AmericanoMade with a lowbrewing pressure to reach a delicate flavourBlack TeaBold and strong.and taste....SteamManual milk frother for a smooth and silky milk foam.www.brandpeople.co.inwww.brandpeople.co.inINDIA DELONGHI DISTRIBUTOR/DEALER INDIA DELONGHI DISTRIBUTOR/DEALEREnjoy exceptional coffee in the mostconvenient way.One touch for espresso.One touch for cappuccino, latte, macchiatoand more.www.brandpeople.co.in INDIA DELONGHI DISTRIBUTOR/DEALER1. One Touch EspressoOne button – that’s all it takes to enjoy exceptional espresso.The digital display is intuitive and easy to use. Each cup brewed is CONSISTENTLY full, rounded, smooth, crema-rich perfect and always at the right temperature.The PrimaDonna Elite has a full-colour touch display with Hot Chocolate function.2. Bluetooth ConnectivityAll at your fingertips, with connectivity, our coffee machine gives you the ability to select your favourite drinks, create new recipes with complete freedom and discover infinite personalisations.What’s more, with “real-time” communication, the Coffee Link App gives unlimited advise and suggestions how to maintain the machine.Available only on PrimaDonna Elite Experience ECAM 650.85.MS and ECAM 650.75.MS.4. Fresh Espresso in Every CupWith our “Tubeless “ technology, ground coffee goes DIRECTLY from the integrated burr grinder to the brewing unit and right into your cup. This ensure maximum freshness.There is a second chamber for you to use pre-ground coffee – great for specialty grounds or decaf!3. One Touch CappuccinoCappuccino, Latte and Latte Macchiato are right at your finger tips too! Fill the milk carafe with milk, attach it directly to the machine and select your favourite cappuccino beverage with one button.Our carafes are designed to fit in your fridge door when not in use!6. ChocolateMade by a dedicated special carafe , adding powdered chocolate to milk, with the option to select the desired level of density (thick, medium, light).Function available in the PrimaDonna Elite ECAM 650.75.MSand ECAM 650.85.MS.8. No Waiting Between CupsTwo separate heating elements, one for espresso preparation and one for milk preparation, ensure the perfect temperature for all drinks.Now you can brew cup after cup instantly.7. Every Cup is CustomisedEasily programme how you like your beverage - temperature, strength and milk-to-espresso ratio. The machine “remembers” exactly how you like your coffee.The PrimaDonna Elite can store up to six personal profiles!5. LatteCrema System - Rich and CreamyOur fully automatic coffee machines are equipped with the breakthrough milk frothing technology - LatteCrema System. With two hydraulic circuits and high precision electronics, this produces the perfect cappuccino beverage every time – perfect in density,temperature and creaminess.11. Milk CarafeOur frothing system is a complete hygienic system. It is designed such that milk NEVER comes in contact with the inside of the machine. The carafe also has an integrated CLEAN FUNCTION turning the control dial to CLEAN activates a rinse cycle of steam and water to clear all pipes of milk residue.The milk carafe is made of only 5 parts which are easy to take apart and put together for deep cleaning.12. Automatic RinseA De’Longhi machine is pre-programmed with an AUTOMATIC SELF-RINSING cycle where it gives itself an internal rinse every time when started up and when switched off . It also has a PREPROGRAMMEDDECALCIFICATION process to prevent the buildup of limescale.10. Easy to ReachOur machines take a FRONTAL APPROACH design. Not only are they elegant with simple lines and subtle curves, all touch points areaccessible from the front, making them easily within reach.9. Removable Brewing UnitOur highly advanced brewing units are very compact, guaranteeing excellent heat distribution and brewing pressure for the perfect cup, Easily removable, the only tools needed to clean it are your fingers. Simply squeeze to release or insert it back in place.The brewing unit’s closed-case design requires no greasing at all!AutenticaCappuccinoDiscover the barista in you. Brew authentic espressos,cappuccinos and lattes to your taste.www.brandpeople.co.inINDIA DELONGHI DISTRIBUTOR/DEALER1. Brew Like a ProWhichever your preference – single or double espresso, cappuccino or latte – the machine brews authentic barista-quality beverages just like what you enjoy at your favourite café.3. Every Cup to your Liking15-bar professional pressure assures quality results every time, and adjustable controls allow you to make modifications for your personal taste preferences.2. Delicious CappuccinoA manual frother mixes steam and milk to create a rich, creamy froth for evenly textured drinks – just the way you like them.*EC860 comes with an integrated milk jug for automatic Cappuccinos4. Easy to UseThe machine does most of the work for you. The Automatic Flow Stop feature dispenses just the right amount of espresso while maintaining the ideal brewing temperature.*For EC860 and EC685 only5. One or Two Espresso Shots?The three-in-one filter holder, included with the unit, has a holder for one espresso shot, a holder for two shots, and one for an easy-to-serve (E.S.E) POD-which ever your preference.7. Accommodates Taller Cups If you prefer larger size beverages no problem. The bottom tray of the unit is easy to adjust or remove to fit taller cups.*For EC860 and EC685 only.6. No Waiting Between CupsThe Rapid Cappuccino maintains the optimal temperature so you can brew cup after cup instantly.8. Easy To Reach And Clean All touch points are accessible from the front, making them easily within reach. The water tank is easy to remove, refill and reattach.Both drip tray and water tank are simple to clean.Malaysia onlyMalaysia onlyAchieve perfect extraction.Good coffee beans deserve a good grindto brew the perfect cup of coffee.Vacuum Coffee Canister (1.6L)A must-have to keep your beans fresh! A one-step motorised sealing system to keep your beans in a vacuum sealed environment.Removable inner container for easy cleaning. Batteries not included.Coffee Tamper (50mm base)For home barista enthusiasts who wants to craft the perfect shot with their pump coffee machines, this tool distributes your coffee evenly and firmly packed in De’Longhi’s filter basket. Stainlesssteel bottom, flat base and ergonomic round handle. Weighs 294g. 100% Arabica Coffee Beans (250g)An exclusive blend developed with Kimbo, an Italian espresso brand, whose mission has been to develop high quality espresso inspired by Italian tradition of over 50 years. 100% Arabica coffeebeans with sweet taste and floral background.Eco Descaler (100ml x 2 packs)Natural limescale remover made of high quality raw materials of plant origins (lactic acid) that are biodegradable and non-polluting to the environment. When used regularly, it helps to extend the life of the machine by preventing accumulation of limescale. Regular descaling also helps reduce energy consumption and keeps your coffee tasting great!Double Wall GlassesAn exclusive set of stylish double wall thermo cups made of Borosilicate glass. Keeps drinks hot or cold, and is condensation free, comfortable to hold and dishwasher safe.Available in sets of 2: Espresso (60ml), Cappuccino (190ml) and Latte (220ml).Milk Cleaner Milk Clean is a sanitising detergent that is delicate on surfaces and specially made for the milk circuit on both automatic and manual milkfrother nozzles and instant frothing device systems (IFD System). Milk Cleancan be used to clean and sanitise the outer parts of the coffee machine.Stainless Steel Milk Frothing Pitcher (0.4L)Designed to use with De’Longhi coffee machines, this is an essential for the home barista for frothing luxuriously smooth milk. High quality stainless steel, easy pouring and ideal for serving two authentic size cappuccinos.INDIA DELONGHI DISTRIBUTOR/DEALERwww.brandpeople.co.in。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档