JAROL,以推动节能技术为已任!前言首先感谢您购买JR6000系列变频器!本使用说明书介绍了如何正确使用JR6000系列变频器。

在使用(安装、运行、维护、检查等)前,请务必认真阅读本使用说明书。

另外,请在理解产品的1嘉兴市佳乐科仪有限公司-JR6000系列产品目录前言 (1)第1章安全信息及注意事项 (4)第2章产品信息 (9)第3章安装 (12)3.1安装环境 (12)3.2安装方向与空间 (12)3.3多台变频器安装 (12)3.4变频器外形尺寸 (13)3.5键盘的安装尺寸 (13)第4章配线 (14)4.1外围设备的连线图 (15)4.2主回路端子接线 (15)4.3控制回路端子连接 (19)4.4符合EMC要求的安装指导 (22)第5章操作面板及操作方法 (25)5.1操作面板说明 (25)5.2操作流程 (27)5.3运行状态 (29)5.4快速菜单 (30)2JAROL,以推动节能技术为已任!第6章详细功能说明 (31)F0组基本功能组 (31)F1组起停控制组 (37)F2组电机参数组 (40)F3组矢量控制功能组 (41)F4组V/F控制功能组 (43)F5组输入端子组 (45)F6组输出端子组 (50)F7组人机界面组 (53)F8组增强功能组 (57)F9组PID控制组 (61)FA组简易PLC及多段速控制组 (64)F B组保护参数组 (68)FC组串行通讯组 (71)F D组预留功能组 (73)FE组厂家功能组 (73)第7章通讯协议 (73)7.1协议内容 (73)7.2应用方式 (73)7.3总线结构 (73)7.4协议说明 (73)7.5通讯帧结构 (74)7.6命令码及通讯数据描述 (75)3嘉兴市佳乐科仪有限公司-JR6000系列产品4第8章 故障对策 (83)8.1故障信息及排除方法 .............................................................................................. 83 8.2 常见故障及其处理方法 .......................................................................................... 87 9.1 日常维护 ............................................................................................................... 88 9.2 定期维护 ............................................................................................................... 88 9.3 变频器易损件更换 ................................................................................................. 89 9.4 变频器的保修 ........................................................................................................ 89 第10章 周边设施选用及配置 .. (89)10.1 制动电阻配置表 .................................................................................................. 89 10.2 断路器、电缆、接触器规格 ................................................................................. 90 10.3输入交流电抗器、输出交流电抗器、直流电抗器规格 ........................................... 91 第十一章 功能参数简表 .. (92)第1章 安全信息及注意事项安全定义:在本手册中,安全注意事项分一下两类:危险:由于没有按要求操作造成的危险,可能导致重伤,甚至死亡的情况;注意:由于没有按要求操作造成的危险,可能导致中度伤害或轻伤,及设备损坏的情况;请用户在安装、调试和维修本系统时,仔细阅读本章,务必按照本章内容所要求的安全注意事项进行操作。

jarol变频器说明书(完整资料).doc

jarol变频器说明书(完整资料).doc

【最新整理,下载后即可编辑】目录第1章序言 (6)1.1特别需要注意的事项 (6)1.2安全注意事项标志 (7)1.3警告标签 (8)1.4开箱检查 (9)1.5产品搬运 (10)1.6产品保存 (10)1.7产品保修 (11)第2章产品概述 (11)2.1JR7000综合技术指标 (12)【最新整理,下载后即可编辑】2.1.1 输入输出特性 (12)2.1.2 外围接口特性 (12)2.1.3 技术性能特性 (13)2.1.4 功能特性 (13)2.2变频器铭牌说明 (14)2.3变频器系列型号 (15)2.4变频器各部件名称说明 (21)第3章安装 (25)3.1安装环境 (25)3.2安装方向与空间 (26)3.3多台变频器安装 (27)3.4变频器外形尺寸 (28)【最新整理,下载后即可编辑】第4章 ....................................................................... 配线314.1外围设备的连线图 (31)4.2主回路接线端子图 (32)4.3主板控制端子 (37)4.5主回路端子功能 (40)4.6标准连接图 (46)4.7主回路的连接 (48)4.7.1 主回路电源侧的连接 (48)4.7.2 主回路变频器侧的连接 (50)4.7.3 主回路电机侧的连接 (51)4.7.4 接地线的连接 (52)【最新整理,下载后即可编辑】4.8控制回路的连接 (52)4.8.1 注意事项 (53)4.8.2 控制板跳线意义 (53)第5章操作面板及操作方法 (54)5.1操作面板说明 (54)5.1.1 面板示意图 (54)5.1.2指示灯说明 (55)5.2操作流程 (57)5.3试运行 (59)5.3.1 运行前检查和准备 (60)5.3.2 简单试运行 (61)第6章详细功能说明 (64)【最新整理,下载后即可编辑】6.1主要功能参数 (65)第7章MODBUS通讯协议 (191)第8章故障对策 (205)8.1变频器故障诊断和纠正措施 (205)第9章保养与维护 (220)9.1基本维护和检查方法 (220)9.2定期检查项目 (222)9.3变频器易损件更换 (224)9.4变频器的保修 (224)第10章功能参数简表 (224)【最新整理,下载后即可编辑】第1章序言非常感谢您使用JR7000 系列通用变频器!1.1 特别需要注意的事项1、在安装本变频器时,请用规定的螺丝固定安装在金属板上!2、实施接线前,务必切断电源!3、变频器内部的电子元件对静电敏感,因此不可将异物置入变频器内部或用手触摸主电路板及元件!【最新整理,下载后即可编辑】4、切断交流电源后,变频器内部部分器件仍有高压余电,请勿触摸内部电路及零件,以防电击!5、变频器调速接地端子务必正确可靠接地!6、绝不可将变频器输出端子接到电源!7、在长时间不使用时,请务必切断电源!8、不能把零线(中性线)接到N(-)上!1.2 安全注意事项标志标志标志意义标志说明危险指出潜在的危险情况,如果不避免,可能会导致人身伤亡!【最新整理,下载后即可编辑】警告指出潜在的危险情况,如果不避免,可能会导致人身轻度或中度的伤害和设备损坏。

佳乐科仪变频器JR7000说明书

佳乐科仪变频器JR7000说明书

目录第1章序言 ............................... 错误!未定义书签。

特别需要注意的事项....................... 错误!未定义书签。

安全注意事项标志......................... 错误!未定义书签。

警告标签................................. 错误!未定义书签。

开箱检查................................. 错误!未定义书签。

产品搬运................................. 错误!未定义书签。

产品保存................................. 错误!未定义书签。

产品保修................................. 错误!未定义书签。

第2章产品概述 ........................... 错误!未定义书签。

JR7000综合技术指标....................... 错误!未定义书签。

输入输出特性........................... 错误!未定义书签。

外围接口特性........................... 错误!未定义书签。

技术性能特性........................... 错误!未定义书签。

功能特性............................... 错误!未定义书签。

变频器铭牌说明........................... 错误!未定义书签。

变频器系列型号........................... 错误!未定义书签。

变频器各部件名称说明..................... 错误!未定义书签。

第3章安装 ............................... 错误!未定义书签。

安装环境................................. 错误!未定义书签。

佳乐科仪变频器jr7说明书

佳乐科仪变频器jr7说明书

目录第1章序言 (4)1.1特别需要注意的事项 (4)1.2安全注意事项标志 (5)1.3警告标签 (5)1.4开箱检查 (5)1.5产品搬运 (6)1.6产品保存 (6)1.7产品保修 (6)第2章产品概述 (6)2.1JR7000综合技术指标 (6)2.1.1 输入输出特性 (6)2.1.2 外围接口特性 (7)2.1.3 技术性能特性 (7)2.1.4 功能特性 (7)2.2变频器铭牌说明 (8)2.3变频器系列型号 (8)2.4变频器各部件名称说明 (10)第3章安装 (10)3.1安装环境 (11)3.2安装方向与空间 (11)3.3多台变频器安装 (11)3.4变频器外形尺寸 (11)第4章配线 (13)4.1外围设备的连线图 (13)4.2主回路接线端子图 (13)4.3主板控制端子 (14)4.4控制端子说明 (14)4.5主回路端子功能 (15)4.6标准连接图 (18)4.7主回路的连接 (18)4.7.1主回路电源侧的连接 (18)4.7.2 主回路变频器侧的连接 (19)4.7.3主回路电机侧的连接 (19)4.7.4接地线的连接 (20)4.8控制回路的连接 (20)4.8.1注意事项 (20)4.8.2控制板跳线意义 (20)第5章操作面板及操作方法 (21)5.1操作面板说明 (21)5.1.1 面板示意图 (21)5.1.2指示灯说明 (21)5.2操作流程 (22)5.3试运行 (22)5.3.1运行前检查和准备 (22)5.3.2简单试运行 (23)第6章详细功能说明 (24)6.1主要功能参数 (24)第7章 MODBUS通讯协议 (69)第8章故障对策 (75)8.1变频器故障诊断和纠正措施 (75)8.2电动机故障和纠正措施 (78)第9章保养与维护 (80)9.1基本维护和检查方法 (80)9.2定期检查项目 (80)9.3变频器易损件更换 (81)9.4变频器的保修 (81)第10章功能参数简表 (82)附录一简单应用举例 (97)第1章序言非常感谢您使用JR7000 系列通用变频器!1.1特别需要注意的事项1、在安装本变频器时,请用规定的螺丝固定安装在金属板上!2、实施接线前,务必切断电源!3、变频器内部的电子元件对静电敏感,因此不可将异物置入变频器内部或用手触摸主电路板及元件!4、切断交流电源后,变频器内部部分器件仍有高压余电,请勿触摸内部电路及零件,以防电击!5、变频器调速接地端子务必正确可靠接地!6、绝不可将变频器输出端子接到电源!7、在长时间不使用时,请务必切断电源!8、不能把零线(中性线)接到N(-)上!1.2安全注意事项标志标志标志意义标志说明危险指出潜在的危险情况,如果不避免,可能会导致人身伤亡!警告指出潜在的危险情况,如果不避免,可能会导致人身轻度或中度的伤害和设备损坏。

佳乐JR7000(JAC780)系列变频器说明书

佳乐JR7000(JAC780)系列变频器说明书

目录第1章序言 (8)1.1 特别需要注意的事项 (8)1.2 安全注意事项标志 (8)1.3 警告标签 (9)1.4 开箱检查 (10)1.5 产品搬运 (11)1.6 产品保存 (11)1.7 产品保修 (11)文档第2章产品概述 (12)2.1 JR7000综合技术指标 (12)2.1.1 输入输出特性 (12)2.1.2 外围接口特性 (12)2.1.3 技术性能特性 (12)2.1.4 功能特性 (13)2.2 变频器铭牌说明 (13)2.3 变频器系列型号 (14)2.4 变频器各部件名称说明 (17)2第3章安装 (21)3.1 安装环境 (21)3.2 安装方向与空间 (21)3.3 多台变频器安装 (22)3.4 变频器外形尺寸 (23)第4章配线 (25)4.1 外围设备的连线图 (25)4.2 主回路接线端子图 (26)4.3 主板控制端子 (31)文档4.4 控制端子说明 (32)4.5 主回路端子功能 (33)4.6 标准连接图 (38)4.7 主回路的连接 (39)4.7.1 主回路电源侧的连接 (39)4.7.2 主回路变频器侧的连接 (40)4.7.3 主回路电机侧的连接 (41)4.7.4 接地线的连接 (41)4.8 控制回路的连接 (42)44.8.1 注意事项 (42)4.8.2 控制板跳线意义 (42)第5章操作面板及操作方法 (43)5.1 操作面板说明 (43)5.1.1 面板示意图 (43)5.1.2指示灯说明 (44)5.2 操作流程 (45)5.3 试运行 (46)5.3.1 运行前检查和准备 (46)文档5.3.2 简单试运行 (47)第6章详细功能说明 (49)6.1 主要功能参数 (49)第7章ModBus通讯协议 (112)第8章故障对策 (119)8.1 变频器故障诊断和纠正措施 (119)8.2 电动机故障和纠正措施 (123)第9章保养与维护 (125)69.1 基本维护和检查方法 (125)9.2 定期检查项目 (126)9.3 变频器易损件更换 (127)9.4 变频器的保修 (127)第10章功能参数简表 (127)文档第1章序言非常感谢您使用JR7000 系列通用变频器!1.1 特别需要注意的事项1、在安装本变频器时,请用规定的螺丝固定安装在金属板上!2、实施接线前,务必切断电源!3、变频器内部的电子元件对静电敏感,因此不可将异物置入变频器内部或用手触摸主电路板及元件!4、切断交流电源后,变频器内部部分器件仍有高压余电,请勿触摸内部电路及零件,以防电击!5、变频器调速接地端子务必正确可靠接地!6、绝不可将变频器输出端子接到电源!7、在长时间不使用时,请务必切断电源!8、不能把零线(中性线)接到N(-)上!1.2 安全注意事项标志8标志标志意义标志说明危险指出潜在的危险情况,如果不避免,可能会导致人身伤亡!警告指出潜在的危险情况,如果不避免,可能会导致人身轻度或中度的伤害和设备损坏。

佳乐变频器说明书

佳乐变频器说明书

目录第1章序言 (5)1.1特别需要注意的事项 (5)1.2安全注意事项标志 (5)1.3警告标签 (6)1.4开箱检查 (7)1.5产品搬运 (7)1.6产品保存 (7)1.7产品保修 (7)第2章产品概述 (8)2.1JR7000综合技术指标 (8)2.1.1 输入输出特性 (8)2.1.2 外围接口特性 (8)2.1.3 技术性能特性 (8)2.1.4 功能特性 (9)12.2变频器铭牌说明 (9)2.3变频器系列型号 (10)2.4变频器各部件名称说明 (12)第3章安装 (16)3.1安装环境 (16)3.2安装方向与空间 (16)3.3多台变频器安装 (17)3.4变频器外形尺寸 (18)第4章配线 (20)4.1外围设备的连线图 (20)4.2主回路接线端子图 (21)4.3主板控制端子 (25)4.4控制端子说明 (26)4.5主回路端子功能 (27)4.6标准连接图 (31)4.7主回路的连接 (33)4.7.1主回路电源侧的连接 (33)24.7.2 主回路变频器侧的连接 (34)4.7.3主回路电机侧的连接 (35)4.7.4接地线的连接 (35)4.8控制回路的连接 (36)4.8.1注意事项 (36)4.8.2控制板跳线意义 (36)第5章操作面板及操作方法 (37)5.1操作面板说明 (37)5.1.1 面板示意图 (37)5.1.2指示灯说明 (38)5.2操作流程 (39)5.3试运行 (40)5.3.1运行前检查和准备 (40)5.3.2简单试运行 (41)第6章详细功能说明 (43)6.1主要功能参数 (43)3第7章 MODBUS通讯协议 (108)第8章故障对策 (114)8.1变频器故障诊断和纠正措施 (114)8.2电动机故障和纠正措施 (118)第9章保养与维护 (120)9.1基本维护和检查方法 (120)9.2定期检查项目 (121)9.3变频器易损件更换 (121)9.4变频器的保修 (122)第10章功能参数简表 (122)附录一简单应用举例 (140)4第1章序言非常感谢您使用JR7000 系列通用变频器!1.1特别需要注意的事项1、在安装本变频器时,请用规定的螺丝固定安装在金属板上!2、实施接线前,务必切断电源!3、变频器内部的电子元件对静电敏感,因此不可将异物置入变频器内部或用手触摸主电路板及元件!4、切断交流电源后,变频器内部部分器件仍有高压余电,请勿触摸内部电路及零件,以防电击!5、变频器调速接地端子务必正确可靠接地!6、绝不可将变频器输出端子接到电源!7、在长时间不使用时,请务必切断电源!8、不能把零线(中性线)接到N(-)上!5危险指出潜在的危险情况,如果不避免,可能会导致人身伤亡!警告指出潜在的危险情况,如果不避免,可能会导致人身轻度或中度的伤害和设备损坏。

佳乐变频器JR8000说明书范文范文

佳乐变频器JR8000说明书范文范文

嘉兴市佳乐科仪有限企业-JR8000系列产品目录第1章前言.....................................................1第2章概括. (2)开箱检查············································· (2)产品搬运············································· (2)产品保存············································· (2)产品保修············································· (2)铭牌说明············································· (3)第安全注意·········································3章事项··4安装······················································4配线······················································5送电······················································6保护······················································6其余······················································6对于机械负载··········································7对于变频器 (8)第4章产品标准规格··········································11产品个别规格··················· (11)产品技术指标··················· (12)第安·························5章装·····························14安装环境····························· (14)安装方向与空间 (14)变频器外形尺寸······························ (15)第6章配线......................................................17主回路配线表示图. (17)接线端子说明图······························ (18)基本连结图····························· (27)主电路配用设备、电线尺寸 (28)第7章操作面板及操作方法····························· (31)I嘉兴市佳乐科仪有限企业-JR8000系列产品第8章简单运行 (34)运行前检查和准备······························ (34)试运行·················································34第9章详尽功能介绍······························ (36)第10章串行通信...........................................101第11章故障对策. (102)故障诊疗和纠正举措 (102)代码比较表 (103)报警显示和解说 (106)电动机故障和纠正举措 (107)第12章养护与保护····························· (110)基本保护和检查方法 (110)按期检查项目······································110第13章周边设备采纳及配置·············· (112)制动电阻配置表·················· (112)第14章应用事例····························· (114)外面电位器的使用····························· (114)内控多段速运行················· (11)4多台变频器连动问题(两种方式)······· (116)工频/变频切换运行·······························119恒压供水 (120)一般变频器的设置所考虑的参数 (121)第15章功能参数简表 (122)II嘉兴市佳乐科仪有限企业-JR8000系列产品第1章前言特别感谢您使用JR8000系列通用变频器!JR8000系列变频器是采纳先进的电力电子技术,由靠谱的元件,优秀的资料精心制造而成。

佳乐科仪变频器JR7000说明书

佳乐科仪变频器JR7000说明书

目录之巴公井开创作创作时间:贰零贰壹年柒月贰叁拾日第1章序言非常感谢您使用JR7000 系列通用变频器!1.1 特别需要注意的事项1、在装置本变频器时,请用规定的螺丝固定装置在金属板上!2、实施接线前,务必切断电源!3、变频器内部的电子元件对静电敏感,因此不成将异物置入变频器内部或用手触摸主电路板及元件!4、切断交流电源后,变频器内部部分器件仍有高压余电,请勿触摸内部电路及零件,以防电击!5、变频器调速接地端子务必正确可靠接地!6、绝不成将变频器输出端子接到电源!7、在长时间不使用时,请务必切断电源!8、不克不及把零线(中性线)接到N(-)上!1.2 平安注意事项标记标记标记意义标记说明危险指出潜在的危险情况,如果不防止,可能会导致人身伤亡!警告指出潜在的危险情况,如果不防止,可能会导致人身轻度或中度的伤害和设备损坏。

这也可用来对不服安操纵进行警戒!1.3警告标识表记标帜贴在变频器的前盖上。

使用变频器时要遵守这些指导。

如下图所示:图1-1 警告标签1.4 开箱检查1、确认变频器在运输过程中无任何损坏(机体上的损坏或缺口)。

2、确认包装箱中有无说明书和保修卡。

3、检查变频器铭牌并确认是否是您所订购的产品。

4、如果您订购了变频器的选配件,请先确认您收到的选配件是否是您所需要的。

5、如有任何疑问,请致电当地经销商。

1.5 产品搬运搬运时,请务必抓住机体底板,如果挪动变频器时仅仅抓住面板或其他非金属部位,则可能造成跌落或破损事故。

带包装多台叠放时,不克不及多于包装箱上标明的可叠放台数,否则可能损坏设备。

1.6 产品保管如果设备在调试之前要存放一段时间,请检查存入地点的环境状态。

变频器应存放在空气流通,周围介质温度在-25℃到+55℃范围内,空气最大相对湿度不超出90%,及无腐蚀性的气体、液体、无污垢的仓库中。

1.7 产品保修JR7000系列变频器的保修期为18个月,保修期从购买本产品之日算起。

厂商只对因产品设计和生产过程中出现的不当所造成的质量问题负责,对于本产品在运输或开箱过程中造成的人为损坏不承担责任,对于不正确的装置使用,如温度,灰尘,腐蚀等不符合规定的工作条件以及过载运行等造成的损坏,厂商不负责任。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

嘉兴市佳乐科仪有限公司-JR8000系列产品目录第1章序言 (1)第2章概述 (2)2.1开箱检查 (2)2.2产品搬运 (2)2.3产品保存 (2)2.4产品保修 (2)2.5铭牌说明 (3)第3章安全注意事项 (4)3.1安装 (4)3.2配线 (5)3.3送电 (6)3.4维护 (6)3.5其它 (6)3.6关于机械负载 (7)3.7关于变频器 (8)第4章产品标准规格 (11)4.1产品个别规格 (11)4.2产品技术指标 (12)第5章安装 (14)5.1安装环境 (14)5.2安装方向与空间 (14)5.3变频器外形尺寸 (15)第6章配线 (17)6.1主回路配线示意图 (17)6.2接线端子说明图 (18)6.3基本连接图 (25)6.4主电路配用设备、电线尺寸 (26)第7章操作面板及操作方法 (28)I嘉兴市佳乐科仪有限公司-JR8000系列产品第8章简单运行 (31)8.1运行前检查和准备 (31)8.2试运行 (31)第9章详细功能介绍 (33)第10章串行通信 (91)第11章故障对策 (92)11.1故障诊断和纠正措施 (92)11.2代码对照表 (92)11.3报警显示和解释 (95)11.4电动机故障和纠正措施 (96)第12章保养与维护 (99)12.1基本维护和检查方法 (99)12.2定期检查项目 (99)第13章周边设施选用及配置 (101)13.1制动电阻配置表 (101)第14章应用案例 (103)14.1 外部电位器的使用 (103)14.2 内控多段速运行 (103)14.3多台变频器连动问题(两种方式) (105)14.4工频/变频切换运行 (107)14.5恒压供水 (108)14.6一般变频器的设置所考虑的参数 (109)第15章功能参数简表 (110)II嘉兴市佳乐科仪有限公司-JR8000系列产品第1章序言非常感谢您使用JR8000 系列通用变频器!JR8000系列变频器是采用先进的电力电子技术,由可靠的元件,优良的材料精心制造而成。

本手册描述了JR8000系列的使用安装、参数设定、异常诊断及日常维护等相关注意事项。

为确保能够正确的安装及操作本变频器,在装机之前,请仔细阅读本手册,敬请妥善保存并交由该机器的使用者。

以下为特别需要注意的事项:1、在安装本变频器时,请用规定的螺丝固定安装在金属板上!2、实施接线前,务必切断电源!3、变频器内部的电子元件对静电敏感,因此不可将异物置入变频器内部或用手触摸主电路板及元件!4、切断交流电源后,变频器内部部分器件仍有高压余电,请勿触摸内部电路及零件,以防电击!5、变频器接地端子务必正确可靠接地!6、绝不可将变频器输出端子接到电源!7、在长时间不使用时,请务必切断电源!8、绝不可将主回路接线端子N接到中性线(零线)!1嘉兴市佳乐科仪有限公司-JR8000系列产品第2章概述2.1开箱检查1、确认变频器在运输过程中无任何损坏(机体上的损坏或缺口)。

2、确认包装箱中有无说明书和保修卡。

3、检查变频器铭牌并确认是否是您所订购的产品。

4、如果您订购了变频器的选配件,请先确认您收到的选配件是否是您所需要的。

如有任何疑问,请致电当地经销商。

2.2产品搬运搬运时,请务必抓住机体金属部位,如果挪动变频器时仅仅抓住面板或其他非金属部位,则可能造成跌落或破损事故。

带包装多台叠放时,不能多于包装箱上标明的可叠放台数,否则可能损坏设备。

2.3产品保存如果设备在调试之前要存放一段时间,请检查存入地点的环境状态。

变频器应存放在空气流通,周围介质温度在-25℃到+55℃范围内,空气最大相对湿度不超过90%,及无腐蚀性的气体、液体、无污垢的仓库中。

2.4产品保修JR8000系列变频器的保修期为一年半,保修期从购买本产品之日算起。

厂商只对因产品设计和生产过程中可能出现的不当所造成的质量问题负责,对于本产品,在运输或开箱过程中造成的人为损坏不承担责任,对于不正确的安装使用,如温度,灰尘,腐蚀等不符合规定的工作条件以及过载运行等造成的损坏,厂商不负责任。

2嘉兴市佳乐科仪有限公司-JR8000系列产品2.5铭牌说明3嘉兴市佳乐科仪有限公司-JR8000系列产品4第3章 安全注意事项为了您的安全,请特别注意本说明书中用到的标记危险:如没有按要求操作,可能会造成死亡或重伤的后果。

注意:如没有按要求操作,可能会造成中等程度伤害或轻伤或造成物质损害的后果。

嘉兴市佳乐科仪有限公司-JR8000系列产品5嘉兴市佳乐科仪有限公司-JR8000系列产品6嘉兴市佳乐科仪有限公司-JR8000系列产品7嘉兴市佳乐科仪有限公司-JR8000系列产品不适合电压在允许工作电压范围之外使用JR8000系列变频器,如果需要,请使用相应的升压或降压装置进行变压处理。

变频器内装有雷击过电流装置,对于感应雷有自保护能力。

8KM1KM2KM3KMnKM1~KMn的选择必须与电机M1~Mn的额定值相匹配,在此情况下,变频器对单台电机无法当变频器接上电源后,不要对变频器内部电路做任何的测量。

第4章产品标准规格4.2 产品技术指标第5章安装5.1 安装环境1、使用环境为-10℃~50℃,若环境温度超过40℃,请置于通风良好之处。

2、使用环境相对湿度必须在0%~95%之间,且无结露。

3、无水滴、蒸气、灰尘及油性灰尘之场所。

4、无漂浮性的尘埃及金属微粒。

5、固定无振动之场所。

6、无电磁杂讯干扰之场所。

5.2 安装方向与空间为了使冷却循环效果良好,最好将变频器安装在垂直方向,因为变频器底部装有冷却风扇以强制制冷,其上下左右与相邻的物品和档板必须保持足够的空间。

如下图5-1所示:图5-1 安装空间距离图0.4KW-7.5KW变频器外形尺寸示意图5.5KW-315KW变频器外形尺寸5.5KW-315KW变频器外形尺寸示意图外形尺寸及安装尺寸第6章配线6.1 主回路配线示意图6.2 接线端子说明图(1)主电路端子排列JR800-0R4G-S2—JR800-2R2G-S2 (塑壳)主回路接线端子JR800-0R7G-4—JR800-3R0G-4 (塑壳)主回路接线端子JR800-4R0G-4—JR800-7R5G-4(塑壳)主回路接线端子JR800-5R5G/7R5P-4—JR800-015G/018P-4主回路接线端子JR800-018G/022P-4 – JR800-055G/075P-4主回路接线端子JR800-075G/090P-4—JR800-090G/110P-4主回路接线端子JR800-100G/132P-4—JR800-315G/350P-4主回路接线端子(2). 控制端子排列0.4KW-7.5KW(塑壳)主板控制端子5.5KW-55KW主板控制端子75KW-315KW主板控制端子(3)控制电路端子功能描述6.3 基本连接图变频器配线部分,分为主回路及控制回路,用户可将外壳的盖子打开,此时可看到主回路端子及控制回路端子,用户必须依照下列之配线回路正确连接。

图为JR8000系列出厂时的标准配置6.4 主电路配用设备、电线尺寸注意∶A、主电路电线的种类为600V IV塑料绝缘电线时的情况。

B、推荐电线截面积假定环境温度为20℃。

C、所谓最大电线截面积为受端子盘限制的最大截面积。

●务必在电源和输入电源端子(R、S、T)之间装上MCCB(断路开关)。

(使用漏电源断路开关时,请使用带高频对策用的开关。

)●接到输入电源端子(R、S、T ) 的配线,无需考虑相序。

●请把电机同输出端子( U 、V 、W ) 正确接线。

●电源线、电机线、控制线的端子,请使用带套管的压接接头。

●输入,输出线的长度以10 米为基准,如果超过10 米,请使用比推荐电线截面积更粗的电线。

●接到控制电路端子的接线,请用屏敝线或绞合绕线,此外,接线时应充分离开主电路、强电电路(包括200V 继电器的时序电路)。

●为防止接到控制电路端子的继电器接触不良,请使用微小信号用接点或是双接点的继电器。

●请将接地端(EG)切实接地。

第7章操作面板及操作方法操作面板说明图7-1 LED操作面板外观●在监视画面下:当变频器处与停止状态时,6位LED数码管闪烁显示监视内容。

当变频器处与运行状态时,6位LED数码管稳定显示监视内容。

LED控制面板的操作:●监视内容画面下的频率设定注意:当操作面板控制功能有效时,在进入频率设置时,START和STOP 键无效。

●监视内容的切换:在监视内容画面下按ENTER键可切换监视参数,键入时先显示监视参数的●功能参数的设置:(例:将第一频率改位:50.00Hz)第8章简单运行8.1 运行前检查和准备运行开始前应重点检查以下各项:●核对接线是否正确。

特别是检查变频器的输出端子U、V、W不能连接至电源,并确认接地端子EG接地良好。

●确认端子间或各暴露的带电部位没有短路或对地短路情况。

●确认端子连接、插接式连接器和螺钉等均紧固无松动。

●投入电源时,使所有开关都处于断开状态,保证投入电源时,变频器不会启动和不发生意外动作。

●投入电源后核对以下各点:◇键盘面板没有故障显示;◇变频器内装的冷却风扇无异物遮挡,风道通畅。

8.2 试运行检查确认无异常情况后,正确设置好变频器运行所需的各项功能参数。

参数设置完成后,可以进行试运行。

试运行时,建议先以较低的频率运行变频器及电机,通过观察无异常情况后逐步提高运行频率。

产品出厂时,设定为REM3(遥控运行)控制方式,可通过参数“Pr-A03”的设定,或STOP+RESET组合键切换控制。

表8-1,常用的操作方法●开始运行按START键,要减速停止按STOP 键。

●运行时检查以下各点。

◇电动机旋转方向是否符合。

◇电动机旋转是否平稳(无啸叫声或振动)。

◇加速/减速是否平稳。

●如无异常情况,则用▲▼键提高频率继续试运行。

经过以上试运行,确认无任何异常情况,然后可以正式投入运行。

第9章详细功能介绍Pr-A01 参数选择出厂值:0设定范围:0~7说明:0:可更改数据1:不可更改数据(用户设置的参数不会被更改,保护数据。

)2-6:保留7:初始化设定(变更为出厂时的设定值)如果操作者不慎将各参数值调乱,可将此参数设为7,并按“ENTER”键,数据将恢复出厂值,再重新设置所需参数。

Pr-A02 控制方式选择出厂值:1设定范围:0~1说明:0:V/F控制方式,在一台变频器拖动多台电机时使用此模式。

1:通用矢量控制,可提高转矩的响应,提供高质量的运转效果。

Pr-A03 操作方式出厂值:3设定范围:0~8说明:此参数主要设置变频器的频率指令来源和运行指令来源。

JR8000系列有LOCAL(本地)和REMOTE(远程)。

当运转停止时,这两种方式才可通过操作面板上“RESET+STOP”组合键来切换。