电梯安装检修运行 Inspection running
在控制柜停电时,用专用短接线短接如下开关。 Turn off the power switch, overbridge switch as follows:
l 上下端站开关Limit switches
SUZHOU EXPRESS ELEVATOR
系统简介 system description in brief
系统结构介绍
F5021
SUZHOU EXPRESS ELEVATOR
电动机参数自学习 Motor auto-tuning
确认安全回路都通、接地良好、无错接线。 Safety circuit is connective and effective grounding. 吊起轿厢,将钢丝绳从曳引轮上取出,使曳引机处于空载状态 Sling the car ,take off the ropes.
电梯调试之OPEX
Commissioning train(OPEX)
2013年2月5日
SUZHOU EXPRESS ELEVATOR
2013/2/5
目 录
电动机参数自学习 Motor auto-tuning 电梯安装检修运行 Inspection running
电梯快车运行调试 Normal running 电梯常见故障表 Error code list
Press the down button in controller, after the lift running well, move the lift continuously in the short distance (about 1m) in two orientations. If the lift runs well and has no abnormal noise, stop the life in the position where the operator can access to the top of the car, prepare the installation of the lift.
电梯额定速度 Car Speed(F6)


电机额定转速 Motor Speed(F7)
编码器脉冲数 Encode Pulse(F8)
具体参见电梯参数表
SUZHOU EXPRESS ELEVATOR
井道信息 Hoistway information
SUZHOU EXPRESS ELEVATOR
井道信息 Hoistway information
分别在控制柜和轿顶分线盒插上随行电缆中插接件及轿顶检修盒到轿顶 分线盒的插接件。而其余不用接插。
Plug plugs to the junction box and to the controller , connect the inspection box to the junction box on the top of the car.
原理图正确连接编码器线 Connect the encoder line exactly according to the schematic diagram.
SUZHOU EXPБайду номын сангаасESS ELEVATOR
电动机参数自学习 Motor auto-tuning
合上电梯供电开关,再分步控制柜内各控制回路电开关。检查所有 电源电压和相序(相序继电器)是否正确。
SUZHOU EXPRESS ELEVATOR
电梯快车运行调试 Normal running
在控制主板上输入电梯常规运行参数。如下参数必须设置正确 set general parameter of the main board exactly according to table • • 总层站数 Total Floor(F11)
SUZHOU EXPRESS ELEVATOR
电梯安装检修运行 Inspection running
在机房内点动检修盒,电梯运行正确以后,两个方向连续多次地以短距 离(1m左右)运行电梯,在电梯各部件没有误动作和异常响声后,把电 梯停靠在安装人员从顶层面能方便进到电梯轿顶。为电梯作安装检修做 准备。
SUZHOU EXPRESS ELEVATOR
电梯安装检修运行 Inspection running
关闭顶层厅门,在轿顶点动操作上下行按钮,注意电梯运行方向,要与 动作的按钮方向一致。 Close the landing door of the top floor, press the up or down button, check if they work well.
SUZHOU EXPRESS ELEVATOR
电动机参数自学习 Motor auto-tuning
输入变频器如下参数 :Input the parameter: T1-01=0 T1-03=电机额定电压 motor rate voltage T1-02=电机输出功率 motor output power T1-04=电机额定电流 motor rate current
Turn on the power switch, then turn on the switches in controller. Check phase and voltage.
确保KMC、KMY接触器吸合;确保电动机抱闸打开 Insure KMC,KMY energize and the break is open. 变频器参数H1-06由9改为F Change Inverter parameter H1-06 from 9 to F
SUZHOU EXPRESS ELEVATOR
电梯安装检修运行 Inspection running
曳引轮转动方向或转速不正确,处理方法如下: If the rotational direction of driving sheave and rotate speed is not correct, please see the following: l 转动方向正确,但转速极慢,并有轻微抖动时,变换编码器的A相和B相 的相位即可 If the rotational direction of driving is correct, but the rotate speed is very slow, change phase A and B of the encoder. l 转动方向相反,转速极慢,变换曳引电动机输入电源相位即可
点动机房检修盒上的下行按钮。 Press the down button in controller. 此时电梯机房至少有两名电梯工作人员,一位观察制动器是否打开, 及曳引轮转动方向、转速是否正确。另一位操作按钮,并观察接触器吸 合情况及的频率输出。当发现异常立即释放按钮
There must be more than two operators in the machine room, one checks the brake operation ,the rotational direction and speed of driving sheave, the other presses the button, observe the status of the motor and inverter, any abnormity, release the push button immediately.
在电梯的安全行程(上下限位)内,以检修运行个来回。仔细观察安装 好的部件与轿厢之间是否挂碰,相对位置及距离是否准确,保障安全。 Inspection operation, look into if the installation parts and car is collide, opposite position and distance is exact.
4 、如出现故障,将显示失败( FAILURE ),并出现故障代 码,,检查并排除故障,重新进行井道距离自学习。
If a fault happens, LCD shows “FAILURE” and fault code, check it and eliminate the fault, try again.
SUZHOU EXPRESS ELEVATOR
电梯快车运行调试 Normal running
3、自学习从最低层开始,直到顶层,止于上端站开关动作。如 完成,液晶显示屏显示成功(SUCCESS)
Lift will run automatically from the down limit switch to the up limit switch, if hoistway learn succeeds, LCD will show “SUCCESS”.
变频器参数表检查运行参数(参见OPEX参数说明)。
Set the parameters according to parameter table
合上电梯供电开关 Operate the power switch
SUZHOU EXPRESS ELEVATOR
电梯安装检修运行 Inspection running
SUZHOU EXPRESS ELEVATOR
电梯快车运行调试 Normal running
电梯舒适感的调整 Final ajustment.
T1-05=电机基频 motor base frequency
T1-07=电机额定转速 motor rate speed
T1-06=电机极数 motor pole number
T1-08=编码器脉冲数 encoder pulse
SUZHOU EXPRESS ELEVATOR
电动机参数自学习 Motor auto-tuning
SUZHOU EXPRESS ELEVATOR
电梯快车运行调试 Normal running 电梯井道距离自学习 Hoistway learn
1 、电梯轿顶置于正常运行状态,用机房检修把电梯驶到下限位 (下限位开关动作)。
Press the down button on the inspection device in controller to move the lift to the down limit switch.
If the rotational direction of driving is contrary, but the rotate speed is very slow, change the power phase of traction motor.
l 转动方向相反,转速正常,编码器和电动机输入电源相位都要变换。 If the rotational direction of driving is contrary, the rotate speed is correct, change both the power phase of traction machine and phase A and B of encoder.
2、把检修开关打到正常运行位置,操作调试器人机界面(液晶 显示屏及微动按钮),设定在井道自学习菜单上,再键入确认 (ENTER)键。如果不出差错,井道自学习将自动进行。
Turn the lift into normal status. Move to the hoistway learn menu, press “ENTER”.
自学习完成后,相关的电机参数将自动存入E2参数中 After auto-turning, the results are automatically saved to E2. 变频器参数H1-06由F改为9 Restore H1-06 to 9
断电后,挂上钢丝绳,,确认轿顶检修正常; Break off the power, load traction ropes, make sure inspection is normal on the car ‘s top.