过载保护器操作说明书

合集下载

ABB Line 过载保护设备说明书

ABB Line 过载保护设备说明书

A C1030– 6/98ABB Control Inc.3.1OVERLOAD RELAYS:General info: 3.1 – 3.2Description•Available for starter construction with A Line contactors and separate panel mounting•Designed for close couple mounting for 11 contactors, A9 – A110•Separate base mounting available for all overload relays•Class 10 adjustable overload relays are standard with all ABB Line starters•Reset can also be adjusted to function as a stop button• Screwdriver guide holes• All terminal screws are available from the front•UL File No: E48139•CSA File No: LR98336•Trip indication•Remote trip and reset option available •Single phase and phase unbalance protection•Isolated alarm circuit (N.O.) contact •Ambient compensation:-25°C to +55°C (-13o F to +131o F)•Manual test•Manual or automatic reset •Factory calibrated and tested •Wide adjustment rangeFrame sizeAmp ratingCatalog number explanationTA25DU 0.16A C 1030 – 6/98ABB Control Inc.3.3OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12Selection guide for Overload relaysThermal O/L relaysTypesTA25DU TA42DU TA75DU TA80DUSelection guideAC 1030 – 6/983.4ABB Control Inc.OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12A C 1030 – 6/98ABB Control Inc.3.5OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12Accessoriesfor Overload relaysDB25/25ADB80DB200LC26-B1Separate mounting kitsDiscount schedule TAA — TA25DescriptionLC terminal blocks can be used to convert standard connections into Faston connections: 2 x 6.3 mm or 4x 2.8mm per pole. The connections are protected against accidental contact.The LC30-T has a terminal block for the 3 power terminals and a second for the 4 auxiliary terminals of a TA25 DU thermal O/L relay.The LC26-B1 has two identical terminal blocks each for 3 power terminals. This block allows the power terminals to be mounted with two DB25 kits or a TA25DU thermal O/L relay and DB25 kit assembly.NOTE: According to DIN 46429 part 1 and NFC 20-120 the max. capacity of a Faston connection is 25A.AccessoriesAC 1030 – 6/983.6ABB Control Inc.OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12Accessoriesfor Overload relaysDS25ADR25AApplication•The DS25-A coil is used for remote electrical tripping of the TA25 DU thermal O/L relay and is connected to the relay's normally closed 95-96 auxiliary contact.•The DR 25-A coil is used for remote electrical resetting of the TA25DU thermal O/L relay which is adjusted for "Manual resetting"; it is connected to the relay's normally open 97-98 auxiliary contact.The coils are not designed for continuous duty. Impulse duration: 0.2 to 0.35 s.Set the button to "Man" (Manual resetting).Mounting: clipped on to TA25DU thermal O/L relay.Installation diagramsFor connection of DS25-A to TA25DU relayFor connection of DR25-A to TA25DU relayRemote tripping coilsTRIPPING COILRESETTINGCOILRESETTINGCOILAccessoriesDiscount schedule TAA — TA25A C 1030 – 6/98ABB Control Inc.3.7OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12Technical data for Overload relays TA25DU – TA110DUSwitching frequencyTo avoid nuisance tripping, TA and T thermal O/L relays have been designed to withstand roughly 15switching operations per hour with an approximately equal distribution between working and rest cycles.In these conditions, the motor starting time must not exceed 1 second and the starting current must be lower than or equal to 6 times the motor I n .For intermittent operations, the diagram opposite specifies relay operating limits.Example:Motor starting time:.................1 sec.Load factor:.............................40 %Switching frequency:...............60 ops./h according to diagramAmbient temperature compensationThermal O/L relays are compensated against ambient temperature variations by a compensation bimetal which is sensitive to the ambient temperature.Thermal O/L relays are designed to operate between –5°C and +40°C in compliance with standard IEC947-4-1.For a wider range of –25° C to +55 °C consult the graph opposite.Example: tripping at –25 °C. Tripping takes place before 1.5 times the setting current.Resetting: TA25DU – TA110DU thermal O/L relays have convertible manual/automatic resetting.Delivery: in manual resetting mode.Tripping limits at ambient temperatures varying by + 20°CM u l t i p l e o f t h e s e t t i n g c u r r e n tAmbient temperatureTechnical dataAC 1030 – 6/983.8ABB Control Inc.OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12Technical data for Overload relays TA25DU – TA110DUPole characteristicsNumber of poles 3Setting rangessee page 3.4Tripping class according to IEC947–410A Operating frequency Hz0 – 400Tripping frequency Up to 15 ops./h or 60 ops./h with 40 % load factor when neither without untimely tripping the starting current of 6 x I n nor the starting time 1s are exceeded.Resistance per phase in m Ωand heat dissipation in Wsee page 3.9at the maximum current settingProtection fusesco-ordination with short circuit protection To be sized per NEC Article 430-152devices1On a support at an angle of ±30° in relation to the vertical plane (standard position). Other positions possible except mounting on a horizontal plane (in this case the tripping mechanism would be located above the bimetals).2 All the terminals are protected against direct contact according to VDE0106/Part. 100. (without additional terminal shrouds).3 All the terminals are protected against direct contact according to VDE0106/Part. 100. (with additional terminal shrouds).Technical dataA C 1030 – 6/98ABB Control Inc.3.9OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12Technical data for Overload relays TA25DU – TA110DUAuxiliary contacts Normally Closed N.C.Normally Open N.O.Terminal marking95 – 9697 – 97Rated insulation voltage U iVAC 500500Conventional thermal current (in free air) I th A 106Rated operation current I e' AC-15up to 240V A 3.0 1.5up to 440V A 1.90.95up to 500V A 1.00.75Rated operational current I e DC-13up to 250V A 0.120.04Protection against short circuits gG (gl) fuses (according to IEC269A 106S271/S 281 circuit breakerA k3k1Maximum potential differenceVAC 500500between N.C. and N.O. auxiliary contactsVDC440440Resistance and Joule Loss per phaseTA42DU Thermal O/L relayTA25DU Thermal O/L relayTechnical dataAC 1030 – 6/983.10ABB Control Inc.OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12T r i p p i n g t i m eM i n u t e sTripping currentin multiples of the setting current S e c o n d s0.8123456789101.21.5T r i p p i n g t i m eM i n u t e sTripping currentin multiples of the setting current S e c o n d s1201008060402010108686442210.8123456789101.21.5T r i p p i n g t i m eM i n u t e sTripping currentin multiples of the setting currentS e c on d s1201008060402010108686442210.8123456789101.21.5Technical dataA C 1030 – 6/98ABB Control Inc.3.11OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12TA25DUTA42DUTA75DU & TA80DUTA110DUAC 1030 – 6/983.12ABB Control Inc.OVERLOAD RELAYS:General info: 3.1 – 3.2Selection: 3.3 – 3.4Accessories: 3.5 – 3.6Technical data: 3.7 – 3.10Dimensions: 3.11 – 3.12TA25DU & AB25TA25DU32 & AB32TA42DU / TA75DU & AB80A。

艾特顿过载保护设备用户说明书

艾特顿过载保护设备用户说明书

Eaton 278467Eaton Moeller® series ZB Overload relay, ZB150, Ir= 25 - 35 A, 1 N/O, 1 N/C, Separate mounting, IP00General specificationsEaton Moeller® series ZB Thermal overload relay278467134 mm121 mm 118 mm 1.394 kgUL 60947-4-1 CSA File No.: 012528 CSA-C22.2 No. 60947-4-1-14 IEC/EN 60947 UL File No.: E29184 CECSA Class No.: 3211-03 VDE 0660 IEC/EN 60947-4-1 ULUL Category Control No.: NKCR CSAZB150-35/KKProduct NameCatalog Number Product Length/Depth Product Height Product Width Product Weight Certifications Model CodeReset pushbutton manual/autoPhase-failure sensitivity (according to IEC/EN 60947, VDE 0660 Part 102) Test/off button Trip-free release-25 °C55 °C-25 °C40 °C CLASS 10 A Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30IP00ZB150Separate mounting Direct attachment25 A35 AIII3Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)FeaturesAmbient operating temperature - min Ambient operating temperature - max Ambient operating temperature (enclosed) - min Ambient operating temperature (enclosed) - max Class Climatic proofingDegree of protection Frame size Mounting method Overload release current setting - min Overload release current setting - max Overvoltage category Pollution degree Product category ProtectionAccessoriesOverload relay ZB up to 150 A6000 V AC4000 V (auxiliary and control circuits)10 g, Mechanical, Sinusoidal, Shock duration 10 ms Branch circuits, (UL/CSA)Continuous≤ 0.25 %/K, residual error for T > 40°1 x (0.75 - 2.5) mm², Control circuit cables1 x (4 - 70) mm², Main cables2 x (4 - 70) mm², Main cables2 x (0.75 - 2.5) mm², Control circuit cables1 x (4 - 16) mm², Main cables2 x (4 - 16) mm², Main cables2 x (0.75 - 4) mm², Control circuit cables1 x (0.75 - 4) mm², Control circuit cables3/0, Main cables2 x (18 - 14), Control circuit cables1 x (16 - 70) mm², Main cables2 x (16 - 70) mm², Main cables24 mm8 mmM10, Terminal screw, Main cables5 mm AF, Hexagon socket-head spanner, Terminal screw, Main cablesM3.5, Terminal screw, Control circuit cables1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver2, Terminal screw, Control circuit cables, Pozidriv screwdriver1.2 Nm, Screw terminals, Control circuit cables10 Nm, Screw terminals, Main cables6 A 5 kA, SCCR (UL/CSA)60 A Class J, max. Fuse, SCCR (UL/CSA)Rated impulse withstand voltage (Uimp)Shock resistanceSuitable forTemperature compensation Terminal capacity (flexible with ferrule)Terminal capacity (solid)Terminal capacity (solid/stranded AWG) Terminal capacity (stranded)Stripping length (main cable)Stripping length (control circuit cable) Screw sizeScrewdriver sizeTightening torqueConventional thermal current ith of auxiliary contacts (1-pole, open)Rated operational current (Ie) at AC-15, 120 V Short-circuit current rating (basic rating) Short-circuit protection rating1.5 A1.5 A0.9 A0.4 A0.2 A0.9 A0.75 A1000 V440 V, Between auxiliary contacts and main contacts, According to EN 61140240 V AC, Between auxiliary contacts, According to EN 61140 440 V AC, Between main circuits, According to EN 61140B600 at opposite polarity, AC operated (UL/CSA)R300, DC operated (UL/CSA)B300 at opposite polarity, AC operated (UL/CSA)600 VAC 100 A gG/gL, Fuse, Type “2” coordination125 A gG/gL, Fuse, Type “1” coordinationMax. 6 A gG/gL, fuse, Without welding, Auxiliary and control circuits111121 W0 W7 W35 A0 WMeets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V Rated operational current (Ie) at DC-13, 110 VRated operational current (Ie) at DC-13, 220 V, 230 V Rated operational current (Ie) at DC-13, 24 VRated operational current (Ie) at DC-13, 60 VRated operational voltage (Ue) - maxSafe isolationSwitching capacity (auxiliary contacts, pilot duty) Voltage rating - max Number of auxiliary contacts (change-over contacts)Number of auxiliary contacts (normally closed contacts) Number of auxiliary contacts (normally open contacts) Number of contacts (normally closed contacts)Number of contacts (normally open contacts)Equipment heat dissipation, current-dependent PvidHeat dissipation capacity PdissHeat dissipation per pole, current-dependent PvidRated operational current for specified heat dissipation (In) Static heat dissipation, non-current-dependent Pvs10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Is the panel builder's responsibility. The specifications for the switchgear must be observed.eaton-tripping-zb-overload-relay-characteristic-curve.epsDA-DC-00004845.pdfDA-DC-00004855.pdfDA-CE-ETN.ZB150-35_KKIL03407006ZDA-CD-zb150_kkDA-CS-zb150_kkeaton-tripping-devices-overload-relay-zb-overload-relay-dimensions-007.epseaton-tripping-devices-overload-relay-zb-overload-relay-3d-drawing-005.eps10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components 10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material 10.10 Temperature rise10.11 Short-circuit rating10.12 Electromagnetic compatibility Characteristic curve Declarations of conformity eCAD model Installeringsinstruksjoner mCAD modelTegningerEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. Med enerett. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaIs the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.13 Mechanical function。

施耐德电气AMDP-D7-SYSC 系列电动机保护器使用手册说明书

施耐德电气AMDP-D7-SYSC 系列电动机保护器使用手册说明书

7.15、AMDP-□/D7 系列电动机保护器7.15.1、电动机故障类型信号输出AMDP-□/D7系列电动机保护器,除保护电动机的继电器触点输出信号外,还配有6个故障类型、1个故障预警、1个故障报警输出信号和1个清除故障状态输入信号。

AMDP-□/D7 系列电动机保护器的DO1-DO6是接地、短路、缺相、堵转、电流不平衡、过载、欠载、过压、欠压故障输出信号,DO7是故障预警信号,DO8是故障报警信号。

电动机没有起动或正常运行时,DO1-DO8输出高电平;电动机发生接地、短路、缺相、堵转、电流不平衡、过载、欠载、过压、欠压故障时,对应的DO信号低电平,故障预警信号DO7也同时为低电平,当故障持续到设定的报警时间,故障预警信号DO7输出高电平,故障报警信号DO8输出低电平。

电动机故障查清、排除后,采取按复位按钮R、加清除故障脉冲信号于DI1、使保护器重新上电中的1种方法之后故障状态被清除,DO1-DO8输出高电平,电动机可重新起动。

AMDP-□/D701的故障状态与DO1-DO8的对应关系如下:DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8接地 短路 缺相 堵转 电流不平衡 过载 预警 报警 AMDP-□/D721的故障状态与DO1-DO8的对应关系如下:DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8接地 短路 缺相 堵转/过载电流不平衡欠载 预警 报警 AMDP-□/D731的故障状态与DO1-DO8的对应关系如下:DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8接地 短路 缺相 堵转/过载/电流不平衡过压 欠压 预警 报警 AMDP-□/D741的故障状态与DO1-DO8的对应关系如下:DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8接地 欠载 缺相 堵转/过载/电流不平衡过压 欠压 预警 报警7.15.2、4-20mA模拟量输出AMDP-□/D7 系列电动机保护器有1路与C相电流成比例、1路与电压成比例的4-20mA模拟量输出,这2路模拟量与采集、保护电路及DSP相隔离。

漏电保护器使用说明书

漏电保护器使用说明书

漏电保护器使用说明书漏电保护器,简称漏电开关,又叫漏电断路器,主要是用来在设备发生漏电故障时以及对有致命危险的人身触电保护,具有过载和短路保护功能,可用来保护线路或电动机的过载和短路,亦可在正常情况下作为线路的不频繁转换启动之用。

国家为了规范漏电保护器的正确使用,相继颁布了《漏电保护器安全监察规定》(劳安字(1999)16号)和《漏电保护器安装与运行(GB13955-92)等一系列标准和规定。

依据这些标准和规定,我们在选用漏电保护器时应遵循以下主要原则:1. 购买漏电保护器时应购买具有生产资质的厂家产品,且产品质量检测合格。

在这里要提醒大家:市场上销售的漏电保护器有不少是不合格品。

2002年10月28日,国家质检总局公布漏电保护器产品质量抽查结果,有20%左右的产品不合格,其主要问题为:有的不能正常分断短路电流,消除火灾隐患;有的起不到人身触电的保护作用;还有一些不该跳闸时跳闸,影响正常用电。

2. 应根据保护范围、人身设备安全和环境要求确定漏电保护器的电源电压、工作电流、漏电电流及动作时间等参数。

3. 电源采用漏电保护器做分级保护时,应满足上、下级开关动作的选择性。

一般上一级漏电保护器的额定漏电电流不小于下一级漏电保护器的额定漏电电流,这样既可以灵敏地保护人身和设备安全,又能避免越级跳闸,缩小事故检查范围。

4. 手持式电动工具(除III类外)、移动式生活用家电设备(除III 类外)、其他移动式机电设备,以及触电危险性较大的用电设备,必须安装漏电保护器。

5. 建筑施工场所、临时线路的用电设备,应安装漏电保护器。

这是《施工现场临时用电安全技术规范》(JGJ46-88)中明确要求的。

6. 机关、学校、企业、住宅建筑物内的插座回路,宾馆、饭店及招待所的客房内插座回路,也必须安装漏电保护器。

7. 安装在水中的供电线路和设备以及潮湿、高温、金属占有系数较大及其他导电良好的场所,如机械加工、冶金、纺织、电子、食品加工等行业的作业场所,以及锅炉房、水泵房、食堂、浴室、医院等场所,必须使用漏电保护器进行保护。

电光防爆说明书 QBZ-80 120 1140 660AN (方壳)

电光防爆说明书 QBZ-80 120 1140 660AN (方壳)

界面(C)
界面(D)
界面(E)
界面(F)
(4)合1#继电器环节:显示界面为(G),将1#继电器合上,以便于回路接通,可以合闸。接着 进行漏电闭锁检测,如没有通过,将显示(H),如果通过,将显示(I),等待开机。
A-6
矿用隔爆型可逆真空电磁起动器
MINE FLAMEPROOF TYPE VACU UM ELECTROMAGNETIC STARTER
5 失压保护 当线路电压突然消失时,起动器动作跳闸。
6 过电压吸收保护 当主回路分断时,瞬间会产生高电压,通过接与主回路中的阻容吸收装置来保护。
四、结构特征
1 起动器由隔爆外壳和真空本体组成,真空本体装于隔爆外壳内。 2 起动器外壳为方壳,前门为快开门结构,壳身上部为接线箱,用于引进电源电缆和引出电机电缆, 且均采取隔爆措施,以达到隔爆要求。在外壳右侧有换向开关的转换手柄和停止按钮。两者有机械联锁, 只有停止按钮按下后,才能扳转手柄并打开前门。 3 真空本体所有元件都装于底板上,其正面装有真空接触器,微机综合保护装置,时间继电器、熔断 器、过电压吸收装置等,背面装有换向开关,变压器及起动、停止按钮。 (具体结构请参考附录中的结构图)
主回路额定工作电压 (V) 380 660
1140
表4
漏电 闭锁 电阻 整定 值(单 相) ( KΩ) 11 22 40
动作值允许误差 (%)
+20 +20 +20
A-3
a)Ise31.60275WZBTRtQ-4e1I/6S40I/e23S
MINE FLAMEPROOF TYPE VACUUM ELECTROMAGNETIC STARTER
五、电气操作说明
1 定值整定表5

电动机保护器的使用说明

电动机保护器的使用说明

ES10系列电动机保护器使用说明书江阴市东歌电气技术有限公司目录1.产品简介 (2)1.1概述 (2)1.2主要性能 (2)1.3引用标准 (2)2.保护器订购选型说明 (3)3.保护器面板及接线端子说明 (4)3.1保护器正面布置 (4)3.2保护器的端子功能 (5)4.ES102编程器功能说明 (6)4.1指示灯功能 (7)4.2 ES102按键功能 (7)4.3 参数设定和查询 (7)4.4故障代码的含义 (19)4.5 符号对照表 (20)5.典型应用接线图 (21)1.产品简介1.1概述ES10系列电动机保护器对电动机的过载、欠载、缺相不平衡、堵转、过热、欠压、过压、接地或漏电等故障引起对电动机的危害给予以系统保护,可实现多种操作控制功能,同时具有测量、自我诊断、维护管理、现场总线通讯等功能。

1.2 主要性能额定工作电压:AC220V/AC380V,消耗功能15W。

电机工作电压:AC380V、660V,50Hz。

额定电流:2A(0.5A~2A);5A(1A~5A);6.3A(1.6A~6.3A);25A(6.3A~25A);100A(25A~100A);250A(63A~250A)。

继电器输出:输出使用继电器隔离,继电器触点额定负载容量a)阻性负载:AC220V(250V)、5A、COSΦ=1,DC24V(30V)、5A。

b)感性负载:AC:AC220V、1.6A ; DC:DC24V 、2A 。

工作环境a)周围环境温度不高于+55℃,不低于-10℃。

b)安装的海拔不超过2500m。

c)污染等级2级。

d)安装类别Ⅲ。

1.3引用标准:本产品符合GB/T14048.1、GB 14048.4、GB/T 17626.2/3/4/5中有关规定。

2.保护器订购选型说明附加功能表1产品代号 表33.保护器面板及接线端子3.1保护器布置图A相B相C相 V通讯运行报警故障编程口%In东歌EASTSONGES-101功能运行signal in注:1: 端子(功能详解见3.2)2: 指示灯:通讯指示灯,在通讯建立后恒亮。

KJZ-400(200) 1140(660)Y

KJZ-400(200) 1140(660)Y

2
速断定值
* *· * * I e
一 般整 定为 额 定电 流的8~1 1倍
3
欠压定值
*·* * ห้องสมุดไป่ตู้ U e
一 般设定电源 电压的30%~7 0%
4
欠压延时
* * ·* * S
可设 定为1~5秒
5
漏电检测电阻
* *· * * KΩ
指漏电动作允许上限值
6
漏电检测延时
* *· * * S
作 总开关时 一般设定0. 3 5秒, 此值 对 分开 关无效
A-5
5.3.2.1 按按“→”、“+”、“取消”或“确定”键进入一级菜单:
√定值查询 参数修改 出口选择 现场测试
√事件记录 信号复归 清除记数 软件版本
5.3.2.2 A、选中“定值查询”按“确定”键,将依次进入其子菜单,定值查询界面下有15个定值,只可查询, 不可修改。 同理: B、进入“参数修改”,在“定值修改”界面下中共有15个定值,配合“↓”,“→”,“取消”, “确定”等按键可以修改。进入定值修改时,首先显示
速断定值 欠压定值 欠压延时 漏电检测电阻 漏电检测延时 监视电压
监视电流 风电瓦斯闭锁延时
电压等级
电流等级 操作密码
装置地址
参数修改
操作 密 码
末端短路定值
相敏保护定值
页面同定值查询,可以修改定值,并增设了“时钟修改”
保护投退
跳闸投退,相敏保护投退,末端保护投退
软件选择
操作 密 码
规约选择
标准规 约, 定制 规约,M OD B US3. 0
3.1 额定电压:660V、1140V; 3.2 额定电流:200A、400A; 3.3 极限分断电流:9000A/660V,7500A/1140V; 3.4 短路保护动作时间:<100毫秒; 3.5 本安参数:Uo:AC5V,Io:20mA; 3..5.1 经1KΩ电阻漏电动作时间:作分支开关时≤30ms;作总开关时,延时时间可调。 3.5.2 在电网每相对地电容不大于1μf,分支每相对地电容不大于0.3μf时,漏电电阻在20K(1140V)、11K

NJBK7电动机保护继电器 说明书

NJBK7电动机保护继电器 说明书

NJBK7电动机保护继电器1 适用范围2 型号及含义N JBK7电动机保护继电器(以下简称保护器),适用于交流50Hz、额定绝缘电压至690V以下,额定工作电流80A-800A的长期工作或间断工作的交流电动机的过载、堵转、断相、三相电流不平衡、接地及P Tc温度等保护。

该保护器采用柔性的罗氏线圈采集电流,具有整定电流范围广,精确度高、安装方便等优点。

该保护器同时具有RS485接口、4mA-20mA模拟量变送接口,可以组网通信,通过上位机对电机实现远程监视、控制,故障查询等功能。

保护器一般与交流接触器配合使用。

符合标准:GB 14084.4、IEC 60947-4-1。

额定控制电源电压(AC220、AC380、AC/DC100V-240V)规格代号设计序号电动机保护继电器企业特征代号N JBK 7-800 /□3 正常工作条件和安装条件3.2 周围空气温度为-5℃~+40℃,且24h内的平均值不超过+35℃。

3.3 大气条件:最高温度为+40℃时,空气相对湿度不超过50%,在较低的温度下可以允许有较高的相对湿 度,例如+20℃时,空气湿度可达90%,并对由于温度变化偶尔产生的凝露,应采取特殊的措施。

3.4 污染等级:3。

3.5 安装面与垂直面的倾斜度不大于±5°。

3.6 在无爆炸危险介质中,且介质中无足以腐蚀金属和破坏绝缘的气体及较多导电尘埃存在的地方。

3.7 在有防雨雪设备及没有充满水蒸气的地方。

3.8 在无显著摇动、冲击和振动的地方。

3.9 安装类别:Ⅲ。

3.10 外壳防护等级:IP20。

3.1 海拔高度:不超过2000m。

4.2 辅助电路:额定绝缘电压AC380V,额定频率50Hz,辅助触点参数型号NJBK7-800/□整定电流(A)800整定电流范围(A)80-800适合电动机功率(kW)40-400使用类别额定工作电压Ue(V)额定工作电流Ie(A)约定发热电流Ith(A)AC-152401.53800.9554 主要参数及性能4.1 主电路:额定绝缘电压AC690V,额定频率50Hz 4.3 结构特点4.3.1 分体安装;4.3.2 L CD显示,按键设定;4.3.3 具有启动延时功能;4.3.4 具有故障记忆功能,能查询故障记录;4.3.5 具有RS485接口,支持MODBUS协议,可组网通讯;5.2 断相保护动作特性主电路三相电流任意一相电流为零时,保护器动作,动作时间≤5s。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

■KOLP 机型选定步骤
KOLP 是依冲床的能力及其它的机械技术参数来计算出合适的机型的。 请按以下的步骤计算、确认必要的条件、并与我司洽询。
★条件设定 ①可供给的气压压力(PA) 1.不超过用户处可以保障供给的气压压力。 2.与煞车离合器或平衡气缸共享同一气压回路的场合 、就以该压力设定。 3.气压压力请以、0.3~0.5 MPa 的范围计算。 ②过载压力的设定(Cp) 1.一般过载压力通常设定为冲床能力的(公称能力值)的大约 110%。 2.根据冲床的加工物内容、冲床本身的钢性请从 100~120 %内决定。
( MPa )



16.0
过载保护油缸流量的计算方法
Q: 过载保护油压缸的瞬间最大排出流量
cm3/s
Q=A×V× 1 10
V = 2πN 60
L・Y-Y2 × Z
A: 过载保护油压缸的面绩 V: 于冲床的最大能力发生点时的滑块下降速度 N: 冲床的冲程数 L: 冲程长度 Y: 能力发生点( 下死奌以上的距离 ) Z: 系数( 1.1 )
③ 此时、另一侧的 O.L.C.里、由于单 向阀只出不进的特性、不会发生油 压上升的情况。
④ 引导阀打开时、两侧的主阀同时打 开、使两侧的 O.L.C.里的作动油排 出。
⑤ 由于上述动作几乎是同时发生、因 此就算发生偏心荷重的情况也能 有效得保护冲床机械。
⑥ 而且、引导阀打开的同时、压力开 关变成 OFF、送出紧急停止信号给 冲床。
( MPa )



16.0

17.0

18.0


19.0


20.0



21.2



22.5



23.5



25.0



26.5


28.0


30.0


31.5

33.5

35.5

※ 在冲床的设计阶段,将过载保护压力统一的话对机器的管理较 方便。
★ 过载动作时的流量检查。
从过载保护油压缸瞬间排出的最大流量、必须小于过载保护装置内,阀有效通径的规定流量值(参照下表『KOLP 标准流量』)。
机种齐全,可对应 (200kN)~(20000kN)
能力的冲床。
适切的预压压力、 可抑制在正常运转时的作动油的压
缩量、确保冲床冲压的精度。
KOLP 性能測試參數(例)デ 过载量
冲床过载保护油 缸测得的油压力
KLOP 的出油口 处测得压力
●其他、PF 型過載保護閥、卡模解脫單元、油壓式荷種監視 器・、沖破負荷模擬裝置、AA.AB 泵等、沖床週邊設備・裝置、 一應俱全。(參照 P15)
标准型的过载保护系统直接配管进 入过载保护油缸的场合。
使用PV/PW偏心荷重对应型过载保 护系统的场合。
当单侧产生负荷时、该侧的过载油压缸内 的油压会上升但是油压会进入另一侧的 油压缸后在两侧的压力超过设定的压力 时过载保护才会动作。
即使只有单侧承受负荷、过载油缸上升的油 压不会进入另一侧的油缸。只有单侧发生过 载时、过载保护系统就会作动两个会油缸同 时开放。
四口两位电磁阀 (常闭型)
压力开关 引导阀
压力保障阀 回油管 吸油滤网 (KOSMEK 制)
◆ KOLP 复原的操作简单。
① KOLP 作动后的复原、非常简 单。
② 复原操作时、将冲床操作模式 切换至『寸动』、将滑块返回 到上死奌、把发生过载的原因 排除以后、在确保安全的状态 下按下复位按钮。
③ KOLP 将重新获得气压的供 给、此时泵重新把预压打进过 载保护油压缸内、压力达到平 衡以后冲床的运转条件就完 成了。
∴从上式所计算结果、与右表『KOLP 流量等级』比对、 本体规格选定“16型、压力代码为 “6” 也就是选定: 气压式的场合为 PH1660
弹簧式的场合为 PL1663
气压式 KOLP
压力 代码
过载动作 压力设定范围
( MPa )
KOLP 供给气压压力 设定值 PA 的计算式
( MPa )

18~25
日本
海外
申请中 10件
23件
已取得
7件
25件

■KOLP 的冲床适用范围及概略构成 ●KOLP ・・・・・・・・有4种型式3种规格、共有10机型可依冲床的机械条件、选择出最适合的机型。
对象 冲床 能力 (kN)

标准型

偏心荷重对应型
气压式
弹簧式
气压式
弹簧式
(作动压力可变式) (作动压力固定式) (作动压力可变式) (作动压力固定式)
弹簧式的场合 从右表中暂定、过载标准作动压为 28.0 MPa KOLP 压力代码为 “6” 。
② 过载排出流量
V = 2πN L・Y-Y2 × Z
60
2π×25 =
300×13-132 × 1.1
60
= 175.9 mm/s
Q = A×V× 1 = 352×π÷4×2×175.9× 1
10
10
= 33,847 cm3/s

■ 动作说明(以气压式的例说明)
Ⅰ.沖床運轉準備
主阀
供给气压进入 KOLP 使过载保护油压缸(O.L.C.)里
达到预压的压力
过载保护油缸
① 供气后气动增压泵开始作动、主阀及引导阀将随着
冲床滑块
预压压力的上升将弹簧往右方移动。
② 开关的接奌变成『ON』、解除冲床的过载保护异 常信号、按下复位开关即可恢复运转。图②
■冲床能力概略对应表
KOLP
本体规格Leabharlann 101635
冲床能力(kN) ~2000
~6000 ~20000
注意 以上所记只是概略的参考值。对于冲床能力的 KOLP 的机型选定、必须 每次根据冲床的实际规格来计算出合适的机型。
☆计算例(5000 KN 冲床的场合)
项目
规格值
记号
供给气压压力(保证值)
MPa
0.55
★ 双曲轴冲床等、滑块宽度大的冲床、在模具的偏位使用,或冲床的多任务位顺 序冲压开始(材料开始进入时)时的模具负荷不稳定的情况下、容易对冲床产生 单侧的过负荷现象。对于这种偏心的荷重、PV/PW偏心荷重对应型 KOLP 的构造是:对各别过载保护油缸拥有其独立性、当单侧油缸发生过负荷时、能 以快速反应以及高精度性能、使两侧的油缸的压力瞬间同时排出、藉此有效的 防止冲床的偏心过负荷。
KOLP 供给压力设定值 PA 计算式 ( MPa )
(PH×87.6)-715.4 2922.5
(PH×73.0)-715.4 2922.5
(PH×62.57)-715.4 2922.5
弹簧式 KOLP 注意:下表的●记号是表示可制作的机型。
弹簧式的场合、建议从下表来选定。
过载保护标准动作压力
压力代码
◆ PH 回路图
压力开关
过载保护油缸(O.L.C.) 增压泵
压力保障阀 吸油滤油网
(KOSMEK 制)
◆ PL 回路图
回油管
过载保护油缸(O.L.C.) 增压泵
气压调压阀
四口两位电磁阀 (常闭型)
引导阀
气压调压阀
◆ KOLP 的功能
能实时反应冲床滑块内过载油压 缸内瞬间上升的压力、快速将作动 油从油压缸排出、同时送出紧急停 止信号给冲床。 冲床紧急停止的同时切断 KOLP 的供给气压。
煞車離合器・平衡缸使用的氣壓力 MPa
0.50
Pa
冲床能力
kN
5000
冲程数
spm
25

冲程长度
mm
300

能力发生点
mm 下死奌上 13 Y
过载保护油压缸的直径
mm
350×2个
① 过载保护作动压力
PH = Cp ×10 = 5000×1.1×10 = 28.6 MPa

352×π/4×2
气压式的场合 过载保护作动压力 = 28.6 MPa ≒ 22~30 KOLP 压力代码 暂定为“6” 。 供给气压压力从右表算出 气压 = 0.47 MPa 算出。
■特長
過載壓力的設定、簡單・精 確。
开关的耐振性可达、 70 G以上。
将引导阀的动作与压力开关直接连 结的设计、当作动油排出的同时,送
出紧急停止的讯号给冲床。
即使过载量
(过载油缸的行程)
增加、 KOLP 的动作精度一样
维持在
+10%以内。 往复精度、±3 %
小型,軽量
反应时间在、 1 msec.以内。
★计算过载保护动作压力(PH)。 请根据下记计算结果来决定。
PH(MPa) =
过载保护动作能力
(k
Cp
过载保护油缸面积 (cm2) × 10 = A × 10
※ 气压式的场合、请从『过载保护压力设定范围』选定『压力代码』、 并倒算出供几气压压力设定值(PA)。
※ 弹簧式的场合、请从[过载保护标准动作压力]中、选定接近的压力值。
PH PL PV PW
其它冲床周边装置
中文简体
KOLP(KOSMEK OVERLOAD PROTECTION SYSTEMS)、以 高速的应答性以及极佳的稳定性、使冲床的性能发挥到极 致。已经成为高効率、安全使用冲床的必备装置。 销售实绩超过 25,000 台。
KOSMEK、以卓越的密封技术,活 用了油压的特性,生产销售多种,极致 的装置。 以其成熟的经验及大量的实绩创造了 最具代表性紧凑设计的、KOLP。
相关文档
最新文档