重庆建设各型压缩机性能参数资料

重庆建设各型压缩机性能参数资料
重庆建设各型压缩机性能参数资料

重庆建设压缩机图片资料一、JSR72系列压缩机图片;

JSR-72Z

二、JSR96系列压缩机图片

JSR96H1Z1

JSR96HZ2V4B

JSR96DB JSR96HTV4-3

三、JSR120/JSRD14系列(同为120CC 排量)

JSR120A JSRD14-7

JSR120ZA JSR120ZV6

特别说明:建设各型号压缩机皮带轮大小和槽数(单槽,双槽,多槽等)可根据客户需要提供。

压缩机参数

QD压缩机的资料 输入功率(W)制冷量(W)电流(A)制冷剂电源(V)应用类型效能 QD2580680.65R12220V-50Hz LBP L QD3082780.65R12220V-50Hz LBP L QD3686880.68R12220V-50Hz LBP L QD431121180.88R12220V-50Hz LBP L QD521281380.98R12220V-50Hz LBP L QD551251321R12220V-50Hz LBP L QD591371461R12220V-50Hz LBP L QD65145158 1.1R12220V-50Hz LBP L QD66150R12220V-50Hz LBP L QD68R12220V-50Hz LBP L QD75162176 1.2R12220V-50Hz LBP L QD80180R12220V-50Hz LBP L QD85184202 1.3R12220V-50Hz LBP L QD91192216 1.4R12220V-50Hz LBP L QD110232271 1.6R12220V-50Hz LBP L QD1282603062R12220V-50Hz LBP QD142280333 2.1R12220V-50Hz LBP QD168330380 2.3R12220V-50Hz LBP L QD180380440 2.8R12220V-50Hz LBP L QD210435510 3.1R12220V-50Hz LBP L QD66D241232 1.4R22220V-50Hz LBP L QD76D252258 1.6R22220V-50Hz LBP L QD91D286300 2.2R22220V-50Hz LBP L QD100D340370 2.5R22220V-50Hz LBP L QD120D360400 2.5R22220V-50Hz LBP L QD150D460546 3.2R22220V-50Hz LBP L QD168D510580 3.55R22220V-50Hz LBP L QD180D550660 2.96R22220V-50Hz LBP L QD210D655790 3.12R22220V-50Hz LBP L QD238D1P R22220V-50Hz LBP L QD268D1+1/8P R22220V-50Hz LBP L QD308D1+1/4P R22220V-50Hz LBP L QD350D1+3/8P R22220V-50Hz LBP L QM238D1+1/8P R22220V-50Hz LBP H QM268D1+1/4P R22220V-50Hz LBP H QM308D1+1/2P R22220V-50Hz LBP H QM350D1+3/4P R22220V-50Hz LBP H

压缩机控制系统概要

压缩机控制技术概述

概述 压缩机是石油、化工、冶金等行业工艺中重要的设备,对机组运行的稳定性,安全性,连续性要求比较高,这样,就需要由高度可靠、高度集成、高度专业的控制系统作为达到以上要求的保证。 概括而言,压缩机的控制系统主要分为以下几个方面: 机组的联锁保护及逻辑功能(ESD)过程调节功能压缩机的防喘振汽轮机调速控制和超速保护 功能说明 一机组的联锁保护及逻辑功能(ESD) 1.报警联锁保护 控制系统监测压缩机,汽轮机,油站等现场的温度,压力,振动,位移等信号,做出相应的高低报警及联锁停机。 2.启停车逻辑 系统能实现机组的开机启动顺序控制,包括机组启动前确认润滑油温度、润滑油压力、控制油压力、透平入口的蒸汽压力及温度达到启动值,防喘振阀全开位置,主气门全开,盘车停止等条件,全部条件满足后输出启动信号。正常停机的卸载控制。 3.油站的油泵控制(A.O.P) 两个油泵互为备用,控制系统可以实现主备油泵的选择,每个油泵可在手动自动方式切

换。如果润滑油压力或控制油压力低,可自动启动备用泵;如果润滑油压力开关动作,以三取二方式实现联锁停车逻辑。 4.汽轮机的冷凝水泵控制(C.E.P) 两个冷凝水泵互为备用,控制系统可以实现主备冷凝水泵的选择,每个冷凝水泵可在手动自动方式切换。冷凝水泵主要是用于冷凝罐的排水泵,可根据液位设定值自动或手动启动停止水泵,两个水泵可同时或单独工作。另外,系统还会做相应的保护,比如,液位如果达到最大设定值,立即强制两个水泵同时运行,如果达到液位最低设定值,立即强制两个水泵同时停止,以保证冷凝罐内的水位正常。 二过程调节功能 汽轮机驱动的压缩机控制回路主要有: 1.油站的油压调节 根据需要,有的油站设计有两个油压调节回路,分别在油泵出口和油过滤器出口,可以根据相应管路的油压要求调节阀门,保证油压的稳定。 2.汽轮机的冷凝水的排放阀和循环阀控制根据汽轮机的冷凝水液位, 调节排放阀和循环阀以控制冷凝罐内 的水位,冷凝水的排放阀和循环阀控制为分层调节,分层点由现场的实际情况来定,可以由用户在操作界面上设定分层点。 3.压缩机段间气液分离器液位控制

压缩机五大机组基本参数

压缩机五大机组基本参数 1、空气压缩机 多轴式压缩机,抽凝式汽轮机驱动。 在合成氨装置中每小时需要2.1万Nm3左右的空气,经过空气压缩机压缩到3.65 MPa后,送至空气加热炉加热到520℃后,进入二段转化炉进行造气反应。此外,尿素装置为防止设备和管道的腐蚀,要求原料CO2中氧气的含量不低于0.6%(体积浓度),所以,还要从空气压缩机的三段出口每小时抽出流量为1 172 Nm3的空气送去CO2压缩机一段分离器出口,称为防腐空气(压力:0.83 MPa,流量:1172 Nm3)。进口压力:0.017 MPa 进口温度:19℃ 出口压力:3.65Mpa 出口温度: 蒸汽条件:8.6 Mpa高压蒸汽驱动汽轮机 压缩机形式:两段六级 流量调节方式:入口导叶+变转速 防喘振旁路:两段放空 汽轮机功率:4900 KW 汽轮机转速:10500rpm/min 对进入空气压缩机中的杂质要求:小于0.03mg/m3 2、原料气压缩机 多轴式压缩机,背压式汽轮机驱动。 合成氨生产中氢气的来源为乙炔尾气,即天然气经不完全氧化生产乙炔后所产生的尾气,其成分主要为H2(60%左右)、CO(28%左右)、CO2(3%左右)、CH4(5%左右),以及少量N2、O2、C2H2、C2H4、Ar 等。 正常工况下,19万吨合成氨装置每小时所需的原料气量为5.5万Nm3,原料气经过原料气压缩机压缩到3. 85 MPa后进行脱硫、加氢、加热(在原料气加热炉中加热到520℃)后,进入二段转化炉进行造气反应。进口压力:0.9 MPa 进口温度:30℃ 出口压力:3.85 MPa 出口温度: 蒸汽条件:3.6 MP中压蒸汽驱动汽轮机 压缩机形式:两段五级 流量调节方式:入口导叶+变转速 防喘振旁路:自动 汽轮机功率:4800KW 汽轮机转速:6000rpm/min 3、合成气压缩机 高、低压缸压缩机,抽凝式汽轮机驱动(双出轴结构)。 合成气压缩机即联压机,包括新鲜合成气和循环合成气的压缩。

压缩机选型设计规范

压缩机选型设计规范 (发布日期:2008-07-21) -- 1适用范围 本规范适用于房间空调器选用定速R22/R407C/R410A制冷剂压缩机时的设计。具体数值如与压缩机厂家提供的规格书有冲突部分,以相应的厂家提供的规格书为准。其它制冷剂压缩机可参考执行。 2规范性引用文件 下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本标准,然而,鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本标准。 GB/T 7725 房间空气调节器 GB 12021.3 房间空气调节器能源效率限定值及节能评价值 QMG-J11.009 家用产品试验指引 QMG-J21.001 房间空气调节器 QMG-J80.004 零部件耐候性试验和评价方法 QMG-J81.001 包装运输试验评价方法 QMG-J81.004 振动运输试验方法 QMG-J82.001 异常噪声检测、判定方法 QMG-J82.007 房间空气调节器凝露试验判定方法 QMG-J82.014 分体式空调器非标安装评价方法 QMG-J84.001 产品可靠性评定导则 QMG-J84.002 产品可靠性试验室评定方法 QMG-J84.006 整机一般环境长期运行试验规范 QMG-J85.004 家用空调和类似用途产品安全标准 3设计要求 3.1 压缩机选用参考: 3.1.1 对于压机本体能力的挑选要根据冷媒种类、设计要求的能效比、所用系统的大小等综合来决定。 (例如要开发EER为3.4的R22冷媒35机,要选的压机本体能力约为3500W,如是R410A 机型则可按下浮5%来选取) 3.1.2 压缩机必须预留有接地螺丝孔(一般为M4)。 3.1.3 对于T1工况机型:在满足整机能效要求情况下尽量选用转子式压缩机,能效实在满足不了才 用涡旋式压缩机。对于T3工况机型:尽量选用转子式压缩机,客户指定时才用活塞式压缩机。

制冷压缩机的基本性能参数计算

制冷压缩机的基本性能参数计算 一、实际输气量(简称输气量) 在一定工况下, 单位时间内由吸气端输送到排气端的气体质量称为在该工矿下的压缩机质量输气量,单位为。若按吸气状态的容积计算,则其容积输气量为,单位为。于是 二、容积效率? 压缩机的容积效率是实际输气量与理论输气量之比值 (4-2) 它是用以衡量容积型压缩机的气缸工作容积的有效利用程度。 三、制冷量 制冷压缩机是作为制冷机中一重要组成部分而与系统中其它部件,如热交换器,节流装置等配合工作而获得制冷的效果。因此,它的工作能力有必要直观地用单位时间内所产生的冷量——制冷量来表示,单位为,它是制冷压缩机的重要性能指标之一。 (4-3) 式中-制冷剂在给定制冷工况下的单位质量制冷量,单位为; -制冷剂在给定制冷工况下的单位容积制冷量,单位为。 为了便于比较和选用,有必要根据其不用的使用条件规定统一的工况来表示压缩机的制冷量,表4-1列出了我国有关国家标准所规定的不同形式的单级小型往复式制冷压缩机的名义工况及其工作温度。根据标准规定,吸气工质过热所吸收的热量也应包括在压缩机的制冷量内。 表4-1 小型往复式制冷压缩机的名义工况

四、排热量 排热量是压缩机的制冷量和部分压缩机输入功率的当量热量之和,它是通过系统中的冷凝器排出的。这个参数对于热泵系统中的压缩机来讲是一个十分重要的性能指标;在设计制冷系统的冷凝器时也是必须知道的。 图4-1 实际制冷循环 从图4-1a所示的实际制冷循环或热泵循环图可见,压缩机在一定工况下的 排热量为: 从图4-1b的压缩机的能量平衡关系图上不难发现 上两式中 -压缩机进口处的工质比焓; -压缩机出口处的工质比焓; -压缩机的输入功率;

压缩机功率对照表以及压缩机详细技术参数

各种型号压缩机功率对照表以及压缩机详细技术参数,此表可作为维修冰箱或空调等制冷设备、更换压缩机的技术依据。 ... 各种型号压缩机功率对照表以及压缩机详细技术参数,此表可作为维修冰箱或空调等制冷设备、更换压缩机的技术依据。 企业名称产品 规格 制冷剂 汽缸容积 (cm3) 名义功率 (HP) 制冷量 (W) 输入功率 (W) 效率 (W/W) 油的 粘度 电机 类型 湖北南光制冷设备有限公司QD56 R12 5.6 132 120 1.1 32 YUR QD63 R12 6.3 145 132 1.1 32 YUR QD72 R12 7.2 165 150 1.1 32 YUR QD80 R12 8.0 186 165 1.12 32 YUR QD88 R12 8.8 200 180 1.11 32 YUR QD96 R12 9.6 233 208 1.12 32 YUR QD110 R12 11 261 238 1.1 32 YUR QD58 R134a 5.8 132 120 1.1 32 YUR QD71 R134a 7.1 148 134 1.1 32 YUR QD78 R134a 7.8 162 145 1.11 32 YUR QD86 R134a 8.6 185 162 1.14 32 YUR Q-5 R22 5.6 750 315 2.38 32 YYR Q-6 R22 6.7 890 370 2.4 32 YYR Q-7 R22 7.1 1000 410 2.44 32 YYR Q-8 R22 8.6 1150 460 2.5 32 YYR 西安远东公司航空工业总公司QD24 R12 2.4 55 75 0.73 22 RSIR QD30 R12 3.0 75 95 0.78 22 RSIR QD45A R12 4.5 113 116 0.95 22 RSIR QD52A R12 5.2 132 139 0.95 22 RSIR QD57A R12 5.7 142 137 1.05 22 RSIR QD62A R12 6.2 154 154 0.95 32 RSIR QD62G A R12 6.2 154 134 1.07 32 RSCR QD75G R12 7.5 190 168 1.09 32 RSCR

压缩机的选型方法

压缩机的选型方法 ①确定热泵的工质,冷凝温度,蒸发温度,容积制热量,制热量,压缩机功率。 表2-30 典型制热温度时的可选工质(部分) GB/T 23137-2008 家用和类似用途热泵热水器 表1 空气源热泵热水器的试验工况

综合考虑制热温度与环境友好的因素,选择R134a为工质。 ②先考虑有无该工质的专用压缩机,如R22,R134a,R717,R744等均有专用压缩机系列。

R134a作为使用最广泛的中低温环保制冷剂,由于R134a良好的综合性能,使其成为一种非常有效和安全的R12的替代品,主要应用于在使用R12制冷剂的多数领域,包括:冰箱,冷柜,饮水机,汽车空调,中央空调,除湿机,冷库,商业制冷,冰水机,冰淇淋机,冷冻冷凝机组等制冷设备中,同时还可应用于气雾推进剂,医用气雾剂,杀虫药抛射剂,聚合物(塑料)物理发泡剂,以及镁合金保护气体等. R134a是目前国际公认的R12最佳的环保替代品.R134a不含氯原子,对臭氧层不起破坏作用,具有良好的安全性能(不易燃,不爆炸,无毒,无刺激性,无腐蚀性):其制冷量与效率与R12非常接近,所以视为优秀的长期替代制冷剂.R134a可广泛用做汽车空调,冰箱,中央空调,商业制冷等行业的制冷剂,并可用于医药,农药,化妆品,清洗行业. 因离心式压缩机与螺杆式压缩机用于150kw以上的制冷量,不适合家用热泵热水器用。又R134a与R12性质相近。为此,选择滚动转子式压缩机进行实验。 ③如有专用压缩机,根据热泵的制热量、功率范围及当地能源情况,确定压缩机的形式。 如制热量较大时可考虑采用离心式压缩机,制热量中等时可采用时考虑螺杆式压缩机,制热量不大时可考虑活塞式、旋转式、涡旋式压缩机。如用电方便时,宜首选封闭式压缩机;用电较紧张时,可考虑采用内燃机或燃气轮机驱动的开启式压缩机。 ④压缩机形式确定后,选择生产该形式压缩机的制造商,查询压缩机的样本资料,根据制 热量确定压缩机型号。 参见 以五星空气院热水器.都市新贵的部分资料为例,

压缩机控制系统

压缩机控制技术概述 概述 压缩机是石油、化工、冶金等行业工艺中重要的设备,对机组运行的稳定性,安全性,连续性要求比较高,这样,就需要由高度可靠、高度集成、高度专业的控制系统作为达到以上要求的保证。 概括而言,压缩机的控制系统主要分为以下几个方面: 机组的联锁保护及逻辑功能(ESD) 过程调节功能 压缩机的防喘振 汽轮机调速控制和超速保护 功能说明 一机组的联锁保护及逻辑功能(ESD) 1. 报警联锁保护 控制系统监测压缩机,汽轮机,油站等现场的温度,压力,振动,位移等信号,做出相应的高低报警及联锁停机。 2.启停车逻辑 系统能实现机组的开机启动顺序控制,包括机组启动前确认润滑油温度、润滑油压力、控制油压力、透平入口的蒸汽压力及温度达到启动值,防喘振阀全开位置,主气门全开,盘车停止等条件,全部条件满足后输出启动信号。正常停机的卸载控制。 3.油站的油泵控制( 两个油泵互为备用,控制系统可以实现主备油泵的选择,每个油泵可在手动自动方式切 换。如果润滑油压力或控制油压力低,可自动启动备用泵;如果润滑油压力开关动作,以三取二方式实现联锁停车逻辑。

4. 汽轮机的冷凝水泵控制( 两个冷凝水泵互为备用,控制系统可以实现主备冷凝水泵的选择,每个冷凝水泵可在手动自动方式切换。冷凝水泵主要是用于冷凝罐的排水泵,可根据液位设定值自动或手动启动停止水泵,两个水泵可同时或单独工作。另外,系统还会做相应的保护,比如,液位如果达到最大设定值,立即强制两个水泵同时运行,如果达到液位最低设定值,立即强制两个水泵同时停止,以保证冷凝罐内的水位正常。 二过程调节功能 汽轮机驱动的压缩机控制回路主要有: 1.油站的油压调节 根据需要,有的油站设计有两个油压调节回路,分别在油泵出口和油过滤器出口,可以根据相应管路的油压要求调节阀门,保证油压的稳定。 2.汽轮机的冷凝水的排放阀和循环阀控制 根据汽轮机的冷凝水液位,调节排放阀和循环阀以控制冷凝罐内的水位,冷凝水的排放阀和循环阀控制为分层调节,分层点由现场的实际情况来定,可以由用户在操作界面上设定分层点。 3.压缩机段间气液分离器液位控制 根据气液分离器液位调节出水阀控制液位。 三压缩机的防喘振 防喘振功能 喘振现象 喘振是涡轮机组特有的现象,我们可以从下图的简单模型来解释 这一特性,从图中可以看出,当容器中压力达到一定值时,压缩机运 行点由 D 沿性能曲线上升,到喘振点 A,流量减小压力升高,这一

综合透平压缩机控制系统ITCC 控制系统方案

综合透平压缩机控制系统ITCC 控制系统方案 概念 综合透平压缩机控制系统Integrated Turbo & Compressor Control System 英文缩写(ITCC)。功能 提供防喘振、联锁停机、电子调速、超速保护、硬件在线诊断、SOE顺序事件记录、 在线换卡、在线下装程序、为压缩机/ 汽轮机附属系统提供监测和保护功能,并且输出报警或停机和关机、对压缩机组实现全部操作和监控及保护,实现节省能源、保护机组的目的。 一. 登录画面 登录画面是用来选择操作员是以什么身份登陆系统,点击登录按钮会弹出以下窗口。 写入登录用户名和口令就可以登录了。登录后在主画面上会显示用户名和用户的级别。以管理员身份登录后,就可以操作画面下方的注销

用户、锁定键盘、解锁键盘操作,还可以点击退出按钮,退出INTOUCH 系统。 操作员可以根据需要点击,选择进入空压机流程画面或氮压机流程画面。 二.空压机流程 点击进入空压机流程主画面,会切换到如下主画面。 此画面显示为空压机气路流程。在画面的左上角为空压机控制主画面选择按钮。按钮右边是报警栏,在报警栏的右边是操作员级别和 身份显示。在操作员级别和身份显示栏右边有如下图案:。这是ITCC控制系统上位于下位之间通讯状态显示,通讯正常时会交替闪烁,如果长时间不闪烁,则表示通讯故障,此时此台操作站显示数据为虚假数据,所有操作失效,需要通知仪表车间检查故障。 在通讯状态显示左边有空压机组报警和氮压机组报警文本框,当

空压机组报警时,空压机组报警字符会交替闪烁,当氮压机组报警时,氮压机组报警字符会交替闪烁。 在画面内,如果通道有错误,在数据栏内,标签名会变为紫色。如下所示:。 在画面中有如下图形:,在方框中图形为空压机入口导叶闭锁显示,当为红色时,表示入口导叶闭锁,当变为绿色时表示闭锁解除。点击该图形,会弹出入口导叶操作画面,如下图所示: OP即为入口导叶的输出值,PV是入口导叶的测量值,点击上下箭头是开关入口导叶,也可以点击OP输出栏数据输入需要开得开度,回车即可(在机组运行期间建议使用按钮点击输入)。

压缩机的智能控制系统

压缩机的智能控制系统 一、需求简述 在原有系统稳定执行的基础上,增加系统故障分析功能、系统决策功能,以实现对压缩机状态参数的分析,对压缩机执行机构的智能控制决策,一是提升控制参数的性能,为用户、系统维护人员提供更好的操作体验;二是实现故障的自动分析判断,为维修人员提供直观的维修指导。 二、系统架构 2.1 硬件系统 如图1、图2所示,在原有PLC控制系统上需扩展串行通讯口,与工控PC进行通信。图2为工控PC的基本接口,其中VGA/HDMI可接现场显示器,USB扩展外设(数据更新、报表打印机等),RJ45和WIFI作为联网可选接口。 图1 系统连接 图2 工控PC的接口需求 2.2、软件系统框架

图3 软件系统总体架构图 系统模块功能: ●数据采集与显示模块 该模块使用Modbus协议,通过RS232或者RS485与PLC控制器进行通讯,获取压缩机运行状态信息,并在显示器上进行显示。 ●数据管理模块 该模块完成对设备运行状态数据的存储、查询和故障事件日记,可由用户或系统管理员更新管理数据。 ●异常现象的监测报警模块:终端设备一旦有异常情况,实现设备断电、故障报警等。 ●故障维修指示模块: 本部分主要根据诊断结果将要维修或调整的相关设备组件拆装图完成,并将动画或图片形式的故障维修策略显示到屏幕上,指导维修人员完成维修工作。 ●智能故障诊断专家系统:本部分是整个智能控制系统的核心部分,整个智能系统要求 具备开放性(扩展性)、自学性和智能性(即随着案例的累积,其故障判断越准,,需要采用相应的数据); 整个系统可分解成故障案例知识库的建立和最佳匹配案例的查找两部分。 核心关键是专家经验、知识的获取和表达,内容重点是:出现的故障情况----故障分析-----采取的故障解除策略。要求知识库部分将专家经验知识的自然语言描述转换为计算机语

冰箱冰柜压缩机性能参数表

冰箱冰柜压缩机性能参数表 文本标签:冰箱冰柜压缩机 型号输入功率(W)制冷量 (W) 电流(A)制冷剂电源(V) QD2580680.65R12220V-50Hz QD3082780.65R12220V-50Hz QD3686880.68R12220V-50Hz QD431121180.88R12220V-50Hz QD521281380.98R12220V-50Hz QD551251321R12220V-50Hz QD591371461R12220V-50Hz QD65145158 1.1R12220V-50Hz QD66150R12220V-50Hz QD68R12220V-50Hz QD75162176 1.2R12220V-50Hz QD80180R12220V-50Hz QD85184202 1.3R12220V-50Hz QD91192216 1.4R12220V-50Hz QD110232271 1.6R12220V-50Hz QD1282603062R12220V-50Hz QD142280333 2.1R12220V-50Hz QD168330380 2.3R12220V-50Hz QD180380440 2.8R12220V-50Hz QD210435510 3.1R12220V-50Hz 文本标签:冰箱冰柜压缩机 型号输入功率(W)制冷量 (W) 电流(A)制冷剂电源(V)

QD66D241232 1.4R22220V-50Hz QD76D252258 1.6R22220V-50Hz QD91D286300 2.2R22220V-50Hz QD100D340370 2.5R22220V-50Hz QD120D360400 2.5R22220V-50Hz QD150D460546 3.2R22220V-50Hz QD168D510580 3.55R22220V-50Hz QD180D550660 2.96R22220V-50Hz QD210D655790 3.12R22220V-50Hz QD238D1P R22220V-50Hz QD268D1+1/8P R22220V-50Hz QD308D1+1/4P R22220V-50Hz QD350D1+3/8P R22220V-50Hz QM238D1+1/8P R22220V-50Hz QM268D1+1/4P R22220V-50Hz QM308D1+1/2P R22220V-50Hz QM350D1+3/4P R22220V-50Hz QD150H295330 2.1R134a220V-50Hz QD168H303350 2.2R134a220V-50Hz QD180H349410 2.7R134a220V-50Hz QD210H400412 3.1R134a220V-50Hz QD25H69590.62R134a220V-50Hz QD30H75750.62R134a220V-50Hz QD55H1151400.9R134a220V-50Hz QD59H1271550.9R134a220V-50Hz QD65H1361671R134a220V-50Hz QD75H153189 1.1R134a220V-50Hz QD85H170212 1.2R134a220V-50Hz QD91H190228 1.4R134a220V-50Hz QD110H230283 1.6R134a220V-50Hz QD128H2573212R134a220V-50Hz QD142H276347 2.1R134a220V-50Hz 文本标签:冰箱冰柜压缩机

冰箱冰柜压缩机性能参数表

创作编号: GB8878185555334563BT9125XW 创作者:凤呜大王* 冰箱冰柜压缩机性能参数表 文本标签:冰箱冰柜压缩机 型号输入功率(W)制冷量 (W) 电流(A)制冷剂电源(V) QD2580680.65R12220V-50Hz QD3082780.65R12220V-50Hz QD3686880.68R12220V-50Hz QD431121180.88R12220V-50Hz QD521281380.98R12220V-50Hz QD551251321R12220V-50Hz QD591371461R12220V-50Hz QD65145158 1.1R12220V-50Hz QD66150R12220V-50Hz QD68R12220V-50Hz QD75162176 1.2R12220V-50Hz QD80180R12220V-50Hz QD85184202 1.3R12220V-50Hz QD91192216 1.4R12220V-50Hz QD110232271 1.6R12220V-50Hz QD1282603062R12220V-50Hz QD142280333 2.1R12220V-50Hz QD168330380 2.3R12220V-50Hz QD180380440 2.8R12220V-50Hz QD210435510 3.1R12220V-50Hz 文本标签:冰箱冰柜压缩机

型号输入功率(W)制冷量 (W) 电流(A)制冷剂电源(V) QD66D241232 1.4R22220V-50Hz QD76D252258 1.6R22220V-50Hz QD91D286300 2.2R22220V-50Hz QD100D340370 2.5R22220V-50Hz QD120D360400 2.5R22220V-50Hz QD150D460546 3.2R22220V-50Hz QD168D510580 3.55R22220V-50Hz QD180D550660 2.96R22220V-50Hz QD210D655790 3.12R22220V-50Hz QD238D1P R22220V-50Hz QD268D1+1/8P R22220V-50Hz QD308D1+1/4P R22220V-50Hz QD350D1+3/8P R22220V-50Hz QM238D1+1/8P R22220V-50Hz QM268D1+1/4P R22220V-50Hz QM308D1+1/2P R22220V-50Hz QM350D1+3/4P R22220V-50Hz QD150H295330 2.1R134a220V-50Hz QD168H303350 2.2R134a220V-50Hz QD180H349410 2.7R134a220V-50Hz QD210H400412 3.1R134a220V-50Hz QD25H69590.62R134a220V-50Hz QD30H75750.62R134a220V-50Hz QD55H1151400.9R134a220V-50Hz QD59H1271550.9R134a220V-50Hz QD65H1361671R134a220V-50Hz QD75H153189 1.1R134a220V-50Hz

压缩机选型计算

压缩机的选型计算 ① -33℃系统(冻结间),取10℃温差,蒸发温度为z t =-33℃。用立式冷凝器,312+=t t ℃、 t t t t ?++= 2 2 11 取(=?t 6℃)冷凝温度为1t =32℃,采用配组双级压缩机,取§=1/3.机械负荷j Q =124845.49w. 解:⑴根据z t =-33℃ 1t =32℃和§=1/3 查图2-1得中间冷却 zj t =-3.5℃ ⑵根据中间冷却温度确定过冷温度g t =(-3.5+4)℃=0.5℃ ⑶根据蒸发温度z t =-33℃和中间冷却温度zj t =-3.5℃,查图2-5得低压级压缩机的输气系数 λ=0.775 ⑷根据蒸发温度z t =-33℃和过冷温度g t =0.5℃,查表2-4得低压级压缩机单位容积制冷量r q =1007kj/3m ⑸计算低压级压缩机的理论输气量: r j d q Q V λ6.3= = 39.5751007 *775.049 .124845*6.3m =/h. ⑹选择低级压缩机。根据计算出的低级压缩机理论输气量,从压缩机产品样本中选两台8AS10和一台4AV10型压缩机作为低压级压缩机,其理论输气量3634m V d =/h ,可以满足要求。 ⑺选择高压级压缩机。根据选定的高、低级压缩机理论输气量之比§=1/3、39.575m V d =/h 得3 d g V V = =(575.9/3)3m /h=191.973m /h 。 从压缩的产品样本中选出两台4AV10型压缩机作为高级压缩机,其理

论输气量36.253m V d =/h 。 实际选配两台8AS10和一台4AV10型压缩机一台作为低压级压缩机,两台4AV10型压缩机一台作为高级压缩机,形成一组配组双级机。 ② -28℃系统(冻结物冷藏间),取10℃温差,蒸发温度为z t =-28℃。用立式冷凝器,312+=t t ℃、 t t t t ?++= 2 2 11 取(=?t 6℃)冷凝温度为1t =32℃,采用配组双级压缩机,取§=1/3.机械负荷j Q = 47347。99w 解:⑴根据z t =-28℃ 1t =32℃和§=1/3 查图2-1得中间冷却 zj t =2.3℃ ⑵根据中间冷却温度确定过冷温度g t =(2.3+4)℃=6.3℃ ⑶根据蒸发温度z t =-28℃和中间冷却温度zj t =2.3℃,查图2-5得低压级压缩机的输气系数 λ=0.78 ⑷根据蒸发温度z t =-28℃和过冷温度g t =6.3℃,查表2-4得低压级压缩机单位容积制冷量r q =1039kj/3m ⑸计算低压级压缩机的理论输气量: r j d q Q V λ6.3= = 332.2101039 *78.099 .47347*6.3m =/h. ⑹选择低级压缩机。根据计算出的低级压缩机理论输气量,从压缩机产品样本中选8AW10压缩机一台作为低压级压缩机,其理论输气量 36.253m V d =/h ,可以满足要求。

压缩机控制系统资料

论文关键词:天然气压缩机组控制系统 论文提要:随着国际、国内油气工业的快速发展,特别是天然气工业的飞速发展,用于天然气增压的往复式天然气压缩机组被越来越多的使用,本文通过对L7044GSI/JGD4型往复式天然气压缩机组的控制系统进行分析,简单介绍了控制系统的结构组成与控制功能的实现。 前言 随着国际、国内油气工业的快速发展,特别是天然气工业的飞速发展,一种用于天然气增压的往复式天然气压缩机组(简称机组)被越来越多的用在长输管道增压输送,地下储气库高压注气,油田气举采油,油田天然气回注,煤层气处理,天然气发电,油气处理厂等场合,虽然不同应用场合下的机组的控制系统略有不同,本文通过对哈萨克斯坦KAM油田使用的美国HANOVER公司成撬的L7044GSI/JGD4型往复式天然气压缩机组控制系统WAHLE CONTROL SYSTEMS进行分析,简单介绍了控制系统的结构组成与控制功能的实现。 1.机组控制系统概述 机组控制系统(Unit Control System,简称UCS)或称机组就地控制系统(Unit Local Control System,简称LCS)通常以就地控制柜的形式安装在机组主撬上或机组主撬附近,由机组供应商成套提供。第一论文范文网https://www.360docs.net/doc/5112819438.html,编辑。 机组控制系统主要由过程控制单元、操作员工作站、数据通信接口等构成,通常,过程控制单元采用可编程序逻辑控制器(PLC),做为人机界面的操作员工作站采用带触摸屏的计算机。因此,机组控制系统实际上是一套以PLC为控制核心,用于机组逻辑顺序控制,PID 控制,实时数据处理,报警停机保护,联网通讯的自动控制系统,可完成单台机组及其辅助系统(空冷器系统、仪表气系统等)的控制。机组控制系统自成体系,独立于站控系统(SCS)以外。 UCS自动、连续地监视和控制压缩机组及其辅助系统的运行,保证人身和设备安全。具体来说,该系统至少满足以下性能:根据命令或条件,按预定程序自动完成机组的启动、加载、卸载和停机/紧急停机等操作;在所有工况下执行对机组的保护;在系统故障或误操作的情况下避免不安全的因素发生;在触摸屏上显示各种工艺变量及其它有关参数;提供声光报警;与SCS交换信息;接受SCS的操作命令。

压缩机控制系统概述

第一章压缩机控制系统概述 利川压气站现设有三台GE PCL503 离心式压缩机组,1号压缩机组(UNIT A)、2号压缩机组(UNIT B)、3号压缩机组(UNIT C),每台压缩机均配有一套UCP (压缩机组控制盘),另外在站控室有两台带监视器、键盘、打印机的个人计算机系统(HMI),为三套压缩机组控制盘(UCP)公用。每套压缩机组控制盘(UCP)构成的主要部件如下: 1、带监视器、键盘、打印机的个人计算机系统(HMI); 2、Bently监视系统; 3、GE-FANUC控制PLC; 4、GE-FANUC ESD(安全)PLC; 5、Ethernet(以太网)交换机;等。 1、控制PLC系统配置图:

控制PLC的构成部件: 1# 机架主机架A 电源模块 IC697PWR724(24VDC 90w) CPU模块 IC697CGR935 母线控制器 IC697BEM731 以太网接口模块 IC697CMM742 串行接口模块 IC697CMM711 2# 机架主机架B 电源模块 IC697PWR724 CPU模块 IC697CGR935 母线控制器 IC697BEM731 以太网接口模块 IC697CMM742 串行接口模块 IC697CMM711 3# 机架 I/O机架电源模块 IC200PWR002 母线接口模块 IC200GBI001 数字量输入模块 IC200MDL650 数字量输入模块 IC200MDL650 数字量输入模块 IC200MDL650 数字量输出模块 IC200MDL742 数字量输出模块 IC200MDL742 模拟量输入模块 IC200ALG240 模拟量输入模块 IC200ALG240 模拟量输入模块 IC200ALG240 4#机架 I/O机架电源模块 IC200PWR002 母线接口模块 IC200GBI001 模拟量输入模块 IC200ALG240 模拟量输入模块 IC200ALG240 模拟量输入模块 IC200ALG240 模拟量输入模块 IC200ALG240 模拟量输入模块 IC200ALG240 模拟量输入模块 IC200ALG620 模拟量输入模块 IC200ALG620 5#机架 I/O机架电源模块 IC200PWR002 母线接口模块 IC200GBI001 模拟量输出模块 IC200ALG320 模拟量输出模块 IC200ALG320 模拟量输出模块 IC200ALG320 模拟量输出模块 IC200ALG320 模拟量输入模块 IC200ALG620 模拟量输入模块 IC200ALG620 模拟量输入模块 IC200ALG620

汉钟压缩机资料

R C 系列
技 术 手 册

目录
一. 二. 三. 四. 五. 六. 七. 八. 九. 十. 十一. 十二. 十三. 概述………………………………2 产品范围…………………………3 产品特点…………………………4 产 品 设 计 ·功 能 … … … … … … … 5 电 气 规 范 … … … … … … … … … … 11 零 部 件 … … … … … … … … … … … 16 应 用 篇 … … … … … … … … … … … 32 安 装 维 护 … … … … … … … … … … 42 应 用 范 围 … … … … … … … … … … 50 性 能 参 数 … … … … … … … … … … 52 尺 寸 篇 … … … … … … … … … … … 64 产 品 保 证 及 服 务 系 统 … … … … … 71 附 表 … … … … … … … … … … … … 72

一 . 概 述 二 . 产 品 范 围 三 . 产 品 特 点 四 . 1. 2. 3. 4. 5. 6. 7. 五 . 1. 2. 3. 4. 六 . 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 七 . 1. 2. 3. 4. 5. 6. 八 . 1. 2. 3. 4. 产 齐 多 有 连 润 压 压 电 压 电 压 各 零 套 关 止 电 液 接 防 液 机 油 保 二 品 全 种 段 续 滑 缩 缩 气 缩 气 缩 项 部 管 断 回 磁 喷 线 震 位 油 压 护 次 设 内 容 式 ( 系 机 机 规 机 组 机 启 计 容 量 容 无 统 设 性 .功 能 积 比 ( Vi) 的 配 置 调节控制 调系统 段)式容 调系统 计规范 能规范
1. 2. 十 . 1. 2. 3. 4.
三段式运 转操作范 围 四段式运 转操作范 围 性 能 参 数 R22 性 能 参 数 R134a 性 能 参 数 R407C 性 能 参 数
范 的 启动条件 件 保 护装置 动 方式参考
十 一 . 尺 寸 篇 1. 压缩机内 部结构图 2. R090-120 外 观 图 3. R155-175 外 观 图 4. R235-445 外 观 图 5. R520 外 观 图 6. R570-780 外 观 图 7. R 系列标 准配备一 览表 十 二 . 产 品 保 证 及 服 务 系 统 1. 产品保证 2. 服务系统 十 三 . 附 表 ( 最新冷媒计 算表)
件 篇 阀 阀 阀 射 盒 垫 开 加 差 模 油
膨 胀阀
关 热 器 开 关 块 分 离器
应 用 篇 液喷射系 统应用 油冷却器 应用 ECO 经 济 器 应 用 储冰系统 应用 环保型冷 媒的应用 润滑油的 选用及操 作 安 压 压 故 保 装 缩 缩 障 养 维 机 机 原 周 护 安 运 因 期 篇 装注意事 项 转注意事 项 分析
九 . 应 用 范 围 篇
1

1,TS3000透平压缩机组综合控制系统(ITCC)

TS3000透平压缩机组综合控制系统(ITCC) 康吉森TS3000透平压缩机组综合控制系统(ITCC)是基于多年旋转设备控制方面的经验,为用户提供一种ITCC (Integrated Turbine & Compressor Control System)机组综合控制系统。它将传统上需要多个分立仪表如防喘调节器、联锁自保系统、电子调速器、负荷调节器等实现的功能集成在一套可靠性极高的三重模件(TMR)冗余容错控制系统中完成;因此,减少了各个系统间的连接和故障率,降低了长周期运行成本,并提供了先进的控制技术和良好的监控界面. TS3000主要控制功能: ●机组安全联锁保护 ●原动机-压缩机的启停及升速的联 锁保护 ●机组的安全运行联锁保护 ●机组的紧急停机联锁保护 ●机组的轴振动/轴位移监视及联锁 保护 ●机组的超速联锁保护 ●机组润滑油/调节油系统联锁保护 ●机组辅助设备的联锁保护 防喘振控制

TS3000响应速度快,安全性高,能以最少的放空量或回流量防止机组的喘振,减少对工艺的干扰和能源的消耗。主要功能是: ●通用防喘振线计算模块消除了分子量变化的影响 ●温度、压力补偿功能 ●任意折线函数功能 ●防止积分饱和功能 ●在喘振控制线附近进行控制 ●根据需要可以设置喘振控制快开线 ●对快速扰动进行超前控制 ●最低负荷启车和停车的功能 ●死区设定实现稳定性 ●动超驰功能 ●安全裕度(Margin)重校功能 ●可变增益控制 ●喘振预报功能 ●分程控制功能 ●快开慢关功能

解耦控制 机组综合控制系统不仅有防喘振控制系统,还有性能控制、调速控制等多个控制,这些控制回路的变量变化是互相影响互相关联的,所以要消除它们之间的干扰或耦合影响。 调速控制 TS3000控制系统针对汽轮机控制实现如下功能: ●转速测量功能转速控制功能 ●辅助控制功能 ●同步负荷分配输入功能串级控制功能 ●阀位限制功能 ●自动、半自动和手动启动功能 ●暖机/额定功能 ●设定临界转速避开带功能 ●汽轮机组调速 ● 超速保护功能 负荷分配控制 TS3000机组综合控制系统针对大型汽轮机及压缩机组的气量负荷分配问题,利用流量控制和压力控制方法,通过以下功能的独立和综合应用实现多机组并联运行时的负荷分配控制,优化系统负荷分配方案: ● 机组流量/压力负荷分配控制

压缩机的基本性能参数

压缩机相关的参数计算 一、实际输气量(简称输气量) 在一定工况下, 单位时间内由吸气端输送到排气端的气体质量称为在该工矿下的压缩机质量输气量 ,单位为。若按吸气状态的容积计算,则其容积输气量为,单位为。于是 二、容积效率? 压缩机的容积效率是实际输气量与理论输气量之比值 (4-2) 它是用以衡量容积型压缩机的气缸工作容积的有效利用程度。 三、制冷量 制冷压缩机是作为制冷机中一重要组成部分而与系统中其它部件,如热交换器,节流装置等配合工作而获得制冷的效果。因此,它的工作能力有必要直观地 用单位时间内所产生的冷量——制冷量来表示,单位为,它是制冷压缩机的重要性能指标之一。 (4-3) 式中 -制冷剂在给定制冷工况下的单位质量制冷量,单位为; -制冷剂在给定制冷工况下的单位容积制冷量,单位为。 为了便于比较和选用,有必要根据其不用的使用条件规定统一的工况来表示压缩机的制冷量,表4-1列出了我国有关国家标准所规定的不同形式的单级小型往复式制冷压缩机的名义工况及其工作温度。根据标准规定,吸气工质过热所吸收的热量也应包括在压缩机的制冷量内。 表4-1 小型往复式制冷压缩机的名义工况

四、排热量 排热量是压缩机的制冷量和部分压缩机输入功率的当量热量之和,它是通过系统中的冷凝器排出的。这个参数对于热泵系统中的压缩机来讲是一个十分重要的性能指标;在设计制冷系统的冷凝器时也是必须知道的。 图4-1 实际制冷循环 从图4-1a所示的实际制冷循环或热泵循环图可见,压缩机在一定工况下的 排热量为: 从图4-1b的压缩机的能量平衡关系图上不难发现 上两式中 -压缩机进口处的工质比焓; -压缩机出口处的工质比焓; -压缩机的输入功率; -压缩机向环境的散热量。 表2-2列举了美国制冷协会ARI520-85标准所规定的用于热泵中的压缩机的名义工况。 表2-2 热泵用压缩机的名义工况(美国制冷协会ARI520-85标准)环境温度35度 五、指示功率和指示效率

相关文档