恒美 M-240说明书(2.0)
MPI Cable 选择指南说明书

MPI Cable Selection GuideMPI engineers focus to provide on optimal cable solutions taking into account a number of requirements specific for wafer-level measurement systems: optimal cable length, cable weight, magnitude, phase, and temperature stability, design, precision, and manufacturing quality of RF connectors, and the lifetime. As a result, MPI can offer two series of RF cables — the high-end MMC and the standard MRC — covering the entire frequency range starting from 18 GHz. This allows engineers to choose the optimal system configuration in dependence of the required measurement accuracy and budget restrictions. Both cable series are design for use at any MPI system platform, from simple manual TS50 prober and up to advanced automated systems with ShieldEnvironment™ and support testing from -60 °C to +125 °C.FeatureBenefitStandard length of 80 cm and 120 cm• Best integration of test instruments with both manual and automated system platforms • Minimal insertion loss• Maximal convenience of operationSpecial design of the male connectorof both MMC- and MRC-series• EMI-, light-tight and ice-free RF measurements on MPI ShieldEnvironment™ systems• Simple and convenient installation of RF probes on the probe arm• Minimal weight-load of the RF probe arm • Stable and consistent RF contact Multi-step armouring of the connector-cable interface• Optimal heatsink, cable weight and diameter combination • Extended cable lifetime• Easy integration with the RF probe arm Optimized cable diameter • Minimal weight-load of the RF probe • Maximal stability of the RF contact • Integration with ShieldEnvironment™• Shortest thermal equilibrium time Excellent magnitude, phase and temperature stability• Longest time of a valid system calibration High-end RF connectors of MMC-series• Best calibration and measurement results• Longest lifetime of the cable assemblyCable StructureInner ConductorInsulation Outer Conductor (a)Outer Conductor (b)JacketMMC – 110A – MF – 200MMC – 67V / 50Q / 40K – MF – 800MMC-Series VSWR Specification0 20 40 60 80 100 1200 10 20 30 40 50 60 70 801.81.71.61.51.41.31.21.11.0876543210V S W R (d B )A t t e n u a t i o n . dB /mFrequency (GHz)Frequency (GHz)MMC Series Attenuation (at 25°C)MMC-Series Stability Test Results on a Probe SystemConnectors of MMC-Series CablesMagnitude and phase stability are key quality criteria of RF cables. Together with the instrument drift, they define lifetime of the system calibration and therefore, the length of the RF calibration cycle, - the period between two system calibrations. Low-quality cables are sensitive to mechanical stress, like accidental hit by system operator that can happen when modifying settings of measured parameters on the instrument front panel. Such accidental stress of MMC cable was simulated on the wafer-level RF measurement system from MPI and its impact on the measurement error of all S-parameters was calculated using NIST calibration comparison method. Reference experiment was contacted on the same system setup for the high-end industry reference RF cables. The results pro-ved that excellent phase and magnitude stability of the MMC-series RF cables from MPI.Quality of connectors is another distinguishing feature of MMC-series of RF cables. Extremely precise manufactured, with exceptional surface quality and special coating, connectors of MMC-series gua-rantee outstanding electrical characteristics and long lifetime of the entire cable assembly.40 GHz K (2.92 mm), Male MMC connector 67 GHz V (1.85 mm), Male MMC connector 110 GHz A (1.0 mm), Male MMC connector50 GHz Q (2.4 mm), Male MMC connector• MMC – 40K– MF – 1200• MMC – 50Q– MF – 1200• MMC – 110A– MF – 250High-Quality MRC-SeriesMRC-Series characteristics, 18 GHz • MRC – 18SMA – MF – 1200MRC-Series characteristics, 26 GHz • MRC – 26SMA – MF – 1200MRC-Series characteristics, 40 GHz • MRC – 40K – MF – 800MRC-Series characteristics, 50 GHz • MRC – 50Q – MF – xxxxMRC-Series characteristics, 67 GHz • MRC – 67V – MF – 800Product PN keyXXX MFXXX XXXX!800: 80 c m !1200: 120 c mCable Length!Male and Female Connector Gender!18SMA : 18 G Hz, SMA !26SMA : 26 G Hz, SMA+!40K : 40 G Hz, 2.92mm !50Q : 50 G Hz, 2.4mm !67V : 67 G Hz, 1.85mm !110A : 110 G Hz, 1.00mm Frequency, Connector Type!MRC : High-quality cable !MMC: High-end cableCable SeriesOrdering reference MMC-seriesItem DescriptionMMC-40K-MF-80040 GHz precision flex cable 2.92 mm (K) connector, male – female, 80 cm MMC-40K-MF-120040 GHz precision flex cable 2.92 mm (K) connector, male – female, 120 cm MMC-50Q-MF-80050 GHz precision flex cable 2.4 mm (Q) connector, male – female, 80 cm MMC-50Q-MF-120050 GHz precision flex cable 2.4 mm (Q) connector, male – female, 120 cm MMC-67V-MF-80067 GHz precision flex cable 1.85 mm (V) connector, male – female, 80 cm MMC-67V-MF-120067 GHz precision flex cable 1.85 mm (V) connector, male – female, 120 cm MMC-110A-MF-125110 GHz precision flex cable, 1 mm (A) connector, male – female, 12.5 cm MMC-110A-MF-200110 GHz precision flex cable 1 mm (A) connector, male – female, 20 cm MMC-110A-MF-250110 GHz precision flex cable 1 mm (A) connector, male – female, 25 cm Ordering reference MRC-seriesItem DescriptionMRC-18SMA-MF-80018 GHz precision flex cable, SMA connector, male – female, 80 cmMRC-18SMA-MF-120018 GHz precision flex cable, SMA connector, male – female, 120 cm MRC-26SMA-MF-80026 GHz precision flex cable, SMA connector, male – female, 80 cmMRC-26SMA-MF-120026 GHz precision flex cable, SMA connector, male – female, 120 cm MRC-40K-MF-80040 GHz precision flex cable, 2,92 mm (K) connector, male – female, 80 cm MRC-40K-MF-120040 GHz precision flex cable, 2,92 mm (K) connector, male – female, 120 cm MRC-50Q-MF-80050 GHz precision flex cable, 2,4 mm (Q) connector, male – female, 80 cm MRC-50Q-MF-120050 GHz precision flex cable, 2,4 mm (Q) connector, male – female, 120 cm MRC-67V-MF-80067 GHz precision flex cable, 1.85 mm (V) connector, male – female, 80 cm MRC-67V-MF-120067 GHz precision flex cable, 1.85 mm (V) connector, male – female, 120 cmAdaptersHigh-In addition, high-quality RF and high-end mm-wave range adapters are offered to address chal-lenges of regular system reconfiguration with different type of test instrumentation.Waveguide to Coaxial AdaptersElectrical SpecificationPart Number MWA-WR15-1MM MWA-WR12-1MM MWA-WR10-1MM Frequency, GHz50 – 7560 – 9075 – 110 VSWR (Max) 1.4 1.4 1.4 Insertion loss, dB0.350.40.55 Connector 1 mm (male) 1 mm (male) 1 mm (male) Waveguide WR-15WR-12WR-10 RF Adapters• Product PN Key•MRA : RF Adapter•MPA : Precision high-end (Microwave)Adapter•M/F : Male/Female•N : 11 GHz adapter, N•350 : 26 GHz adapter, 3.5 mm•292 : 40 GHz adapter, 2.92 mm•240 : 50 GHz adapter, 2.4 mm•185 : 67 GHz adapter, 1.85 mm•100 : 110 GHz adapter, 1.0 mmMPI Global PresenceDirect contact:Asiaregion:****************************EMEAregion:******************************Americaregion:********************************MPI global presence: for your local support, please find the right contact here:/ast/support/local-support-worldwideSee MPI Corporation‘s Terms and Conditions of Sale for more details.Item DescriptionMRA-NM-350F 11 GHZ RF adapter, N(M)-3.5(F)MRA-NM-350M 11 GHZ RF adapter, N(M)-3.5(M)MPA-350M-350F 26 GHZ precision RF adapter, 3.5(M)-3.5(F)MPA-350F-350F 26 GHZ precision RF adapter, 3.5(F)-3.5(F)MPA-350M-350M 26 GHZ precision RF adapter, 3.5(M)-3.5(M)MPA-292M-240F 40 GHZ precision RF adapter, K(M)-Q(F)MPA-292F-240M 40 GHZ precision RF adapter, K(F)-Q(M)MPA-292M-292F 40 GHZ precision RF adapter, K(M)-K(F)MPA-292F-292F 40 GHZ precision RF adapter, K(F)-K(F)MPA-292M-292M 40 GHZ precision RF adapter, K(M)-K(M)MPA-240M-240F 50 GHZ precision RF adapter, Q(M)-Q(F)MPA-240F-240F 50 GHZ precision RF adapter, Q(F)-Q(F)MPA-240M-240M 50 GHZ precision RF adapter, Q(M)-Q(M)MPA-185M-185F 67 GHZ precision RF adapter, V(M)-V(F)MPA-185F-185F 67 GHZ precision RF adapter, V(F)-V(F)MPA-185M-185M 67 GHZ precision RF adapter, V(M)-V(M)MPA-185M-100F67 GHZ precision RF adapter, V(M)-A(F)RF Adapters•Electrical Specification。
DUO-240中文说明书

5.2红外单元步行测试:
1、把微波距离调到MIN(最小)
2、确认DIP开关SW-3打到ON(绿色LED作为步行测试指示灯)。
3、装好探测器的上盖。
4、走入探测器的保护区,观察保护区的边缘。每次触发探测器,绿色LED会闪烁5秒。
划、压、等意外损毁。
B、将底座打开至少1个出线孔,见图3,以2个螺钉、膨胀栓等固定在顶棚的所选位置。
3.3接线:
见图4。
4.2模式选择:
模式DIP开关位于电路板上,如图5。
它控制4个功能,如图5及表2所示。
5.设置
5.1设置红外脉冲计数
如果要最大限度降低误报,就把DIP开关SW-1打到ON,此时必需有2个脉冲才能触发红外单元。
环境要求:
工作温度:-10℃-- 50℃
储藏温度:-20℃-- 60℃
RFI防护:大于30V/M
专利:U.S.5237330(及其他未定专利)
3.2安装
选择适当的安装位置,确保保护区内的主要通道、目标在保护区域内,DUO-240最大安装高度为4.5米。
安装过程:
A、一手握住底座,如图2,另一手旋转上盖,对正缺口,取下上盖,放在安全处,以防
4、调节微波的探测距离(由MIN逐渐向MAX),通过步行测试,确认微波探测距离符合需要。
5、匀速穿过保护区域,确认您的移动被不断探测到。
5.4报警步行测试:
1、DIP开关SW-2和SW-3都打到ON(两个LED的功能都启动)。
2、暂时装好探测器的上盖。
3、从不同距离、不同方向走入探测器的保护区,确认在整个保护范围内的移动都能被探测到(红色LED会亮2-3秒)。
PDH120 240 480+100M系列光端机说明书

PDH120/240/480+100M光传输设备用户手册安全使用须知PDH120/240/480+100M系列综合业务传输设备在设计使用范围内具有良好可靠的性能,但仍应避免人为对PDH120/240/480+100M系列综合业务传输设备造成的损害或破坏。
◆仔细阅读本手册,并保存好本手册,以备将来参考用;◆不要将设备放置在接近水源或潮湿的地方;◆不要在电源电缆上放任何东西,不要将电缆打结或包住,并应将其放在不易碰到的地方;◆电源接头以及其它设备连接件应互相连接牢固,请经常检查;◆连接电源线时,务必认真按接线柱标注接线;所用电源必须满足如下条件:1.直流-48V机种:-36V ~-72V2.交流220V机种:220V±20%,50Hz◆请注意设备清洁,必要时可用软棉布擦拭;◆不要堵塞通风口;◆在下列情况下,请立即断开电源,并与公司联系:1.设备进水;2.设备摔坏或机壳破裂;3.设备工作异常或展示的性能已完全改变;4.设备产生气味、烟雾或噪音。
◆请不要自己修理设备,除手册中有明确指示外。
一、概述PDH120/240/480+100M系列综合业务传输设备是本公司使用自主开发的专用集成电路研制生产的综合业务传输设备。
它将标准的2M传统TDM业务接口、V.35业务接口与10/100BaseTx以太数据业务接口融为一体,并转变为高速光信号,在光纤上进行传输,同时支持双光路1+1无损保护,从而使高速数据业务和传统TDM业务在同一对光纤上传输成为可能,以最小的成本满足用户对高速数据业务和传统TDM业务综合接入的需求。
PDH120/240/480+100M系列综合业务传输设备维护简单,开电即用,还可提供集中式局端设备,并提供完整的网络管理功能。
二、主要特点◆E1数字口阻抗75Ω/120Ω可选;◆以太接口均为10/100Base-Tx自适应,带宽可以0.5M为单位调整,最大带宽100M;◆E1通道支持内置BERT(Bit Error Rate Test);◆提供1个公务话机接口;◆提供1个RS232异步数据接口;◆提供1个管理接口,可实现集中监控,并支持系统升级;◆提供一组控制开关,用于设置设备维护测试;◆双光路光端机可实现业务的1+1无损保护;◆采用大规模芯片,电路简单,功耗低,可靠性高;◆适应多种电源环境,-48VDC或220V AC;◆标准1U机框,体积小,重量轻,工作稳定可靠,安装方便。
1600kg客梯2.0速度设计计算书

TKJ1600/2.0-JXW/VVVF 交流变频乘客电梯设计计算书电梯2010年10月20日目录1 电梯型号 (1)2 主要参数 (1)3 曳引驱动计算 (1)3.1 曳引电动机功率计算 (1)3.2 轿厢面积计算 (1)3.3 轿厢通风面积的计算 (2)3.4 曳引轮输出额定扭矩 (2)3.5 主轴最大静载荷 (2)3.6 悬挂绳安全系数计算 (2)4 导轨承载计算 (4)5 曳引条件计算 (4)6 结构计算 (5)7 缓冲器的验算 (7)8 安全钳选用 (7)9 限速器的选用 (7)10 底坑空间和顶层空间计算 (8)11 紧急救援措施 (9)12 超速及其它保护装置的说明资料 (9)13 导轨的说明资料 (12)14 轿厢和门系统的说明资料 (12)15 轿门护脚板 (13)16 门系统说明资料 (13)17 机械部件的防护 (14)18 电梯整机性能指标 (14)19 样梯可靠性运行记录和总结 (15)1 电梯型号TKJ1600/2.0-JXW/VVVF 交流变频乘客电梯2主要参数载重量:Q=1600kg 运行速度:V=2.0m/s 提升高度:H=53.1米曳引比:I=2:1曳引包角:α=180˚轿厢自重:P=1200㎏3 曳引驱动计算3.1曳引电动机功率计算:取平衡系数Φ=0. 45 取η=0.85计算公式: P=QV(1-Φ)=1600×2×(1-0. 45)=20.3KW 102ŋ102×0. 85选用蜗轮蜗杆曳引机,额定功率P1=22KW, 所以适用。
曳引轮节径D1=400mm曳引绳根数m=7,直径d=Φ10mm,额定转速n=191r/min 上开口角r=35°下部切口角β=90°额定速度验算:η1=60×2×2/(3.14×0.5)=152г/min 适用3.2轿厢面积计算轿厢净宽A=1900mm,轿厢净深B=1800mm轿厢有效面积S=1.9×1.8=3.42m2标准五吨轿厢面积为3.56 m2所以本电梯不超标共15 页第 1 页3.3轿厢通风面积的计算轿厢通风面积不应小于轿厢有效面积的1%,即均为0.02 m2 S下+S下=0.27×0.045+(1.35×2+1.4)×0.005=0.032 m2>0.02m2 所以上下部的通风面积足够3.4.曳引轮输出额定扭矩M1M1= 9550×22×2×0.85=2349(N·m)152实际运行扭矩M2按超载10%计算M2= (1.1-0.45)×1600×20.3×0.4=2111 N·m< M1所以满足2×23.5.主轴最大静载荷T曳引绳Φ10质量q=0.34㎏/m 曳引绳根数m=5T= 1200+1.25×1600 +7×0.34×53.1+1200+1600×0.45+2.85×132 2=2614㎏<曳引机允许静载荷,所以通过3.6.悬挂绳安全系数计算K P=4=1β=90°Nequiv( t )=5Nequiv(P)= 3Nequiv= 5+3=8共15 页第 2 页许用安全系数S f=10×(2.6834- )=17Φ10最小破断力T K=44000N安全系数S=44000×7/[(1200+1600)/2+53.1×7×0.34]×9.8=2121>17 所以满足共15 页第 3 页4.导轨承载计算(按中心导向安全钳动作为最严重工况)轿厢导轨T89/B材料抗拉强度370Mpa,截面积A=15.7cm2i x=1.98cm i y =1.84cm 导轨与等距L K=200cmI x =59.7 cm4I y =53cm4W x =14.5cm3W y =11.9cm3轿厢导靴间距h=3350 轿厢尺寸宽A=1.9m深B=1.8m导轨许用应力δporm =205Mpa 最大允许变形[δy ]为5mm细长比λ=LK/ίx=200/1.98=101.01 查表得ω=1.9 K=2F K = [K×(P+Q) g]/2= [2×(1200+1600)×9.8]/2=27440N压弯应力δK=(F K×w)/A=27440×1.9/(15.7×102)=33.2Mpa 载荷偏心距X Q=B /8=1800/8=225mm Y Q=0F x=(3×9.8×1600×225)/(2×3350)=1579NM y=(3F x×Lk)/16=(3×1579×2000)/16=592125Nmm弯曲应力δy =My/Wy=592125/(11.9×103)=49Mpa挠度δx =0.7×(F x×L K3)/(48×E×I y)=(0.7×1579×2003)/(48×2×107×108)=0.085cm =0.85mm以上均通过,符合要5.曳引条件计算5.1按125%额定载荷轿厢位于最底层装载静态工况计算。
MOXA IA240系列Arm基础200MHz工业计算机产品介绍说明书

IA240SeriesArm-based192MHz industrial computer with2LAN ports,4serial ports,4DIs,4DOsFeatures and Benefits•MOXA ART32-bit Arm9industrial processor•64MB RAM,16MB flash onboard•4RS-232/422/485serial ports•4digital input and4digital output channels(TTL signal)•Dual10/100Mbps Ethernet ports•SD slot for storage expansion•Ready-to-run Linux kernel2.6platform•Unique patented software encryption lock•Installation options:DIN-rail,wall-mount(with accessory)•Robust,fanless design,IP30protection mechanism•-40to75°C wide-temperature models availableCertificationsIntroductionThe IA240embedded computers are designed for industrial automation applications.The computers feature4RS-232/422/485serial ports,dual Ethernet ports,4digital input channels,4digital output channels,and an SD slot in a compact,IP30-protected,industrial-strength rugged housing. The IA240’s vertical DIN-rail form factor makes it easy to install the computers in a small cabinet.This space-saving solution also facilitates easy wiring,making the IA240a great choice as a front-end embedded controller for industrial applications.Wide-temperature models of the IA240are also available.The IA240-T model can operate reliably in a temperature range from-40to75°C,making it appropriate for harsh industrial automation environments.The industrial design of the IA240provides a robust,reliable computing platform.Due to their Arm-based architecture,the IA240computers will not generate a lot of heat,making them ideal for industrial automation environments.AppearanceFront View Top ViewSpecificationsComputerCPU MOXA ART Arm9,192MHzStorage Slot SD slots x1Supported OS Linux kernel version2.6MemoryFlash16MBSDRAM64MBComputer InterfaceEthernet Ports Auto-sensing10/100Mbps ports(RJ45connector)x2 Serial Ports RS-232/422/485ports x4,software selectable(RJ45) USB2.0USB2.0hosts x1,type-A connectorsDigital Input DIs x4Digital Output DOs x4Digital InputsConnector Screw-fastened Euroblock terminalVoltage Logic0:0-0.8VLogic1:2.0-5.5VDigital OutputsConnector Screw-fastened Euroblock terminalCurrent Rating24mA per channelVoltage Logic0:0-0.55VLogic1:2.5-3.3VEthernet Interface10/100BaseT(X)Ports(RJ45connector)2Magnetic Isolation Protection 1.5kV(built-in)USB InterfaceStorage Port USB Type AUSB Standards USB1.1/2.0compliantLED IndicatorsSystem Power x1System Ready x1LAN2per port(10/100/1000Mbps)Serial2per port(Tx,Rx)Serial InterfaceBaudrate50bps to921.6kbps(supports non-standard baudrates)Connector8-pin RJ45Console Port RS-232(TxD,RxD,GND),8-pin RJ45(115200,n,8,1)Data Bits5,6,7,8Flow Control RTS/CTS,XON/XOFF,ADDC®(automatic data direction control)for RS-485,RTSToggle(RS-232only)ESD Protection4kV,for all signalsNo.of Ports4Parity None,Even,Odd,Space,MarkRS-485Data Direction Control ADDC®(automatic data direction control)Serial Standards RS-232/422/485Stop Bits1,1.5,2Serial SignalsRS-232TxD,RxD,RTS,CTS,DTR,DSR,DCD,GNDRS-422Tx+,Tx-,Rx+,Rx-,GNDRS-485-2w Data+,Data-,GNDRS-485-4w Tx+,Tx-,Rx+,Rx-,GNDPower ParametersInput Current300mA@24VDCInput Voltage12to48VDCNo.of Power Inputs1Power Connector3-pin terminal blockPower Consumption7W(max.)Physical CharacteristicsHousing MetalDimensions60x137x100mm(2.36x5.39x3.94in)Weight430g(0.96lb)Installation DIN-rail mounting,Wall mounting(with optional kit)Environmental LimitsOperating Temperature IA240-LX:-10to60°C(14to140°F)IA240-T-LX:-40to75°C(-40to167°F)Storage Temperature(package included)IA240-LX:-20to80°C(-4to176°F)IA240-T-LX:-40to85°C(-40to185°F)Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsEMC EN55032/24,EN61000-3-2Class A,EN61000-3-3,EN61000-6-2/-6-4 EMI CISPR32,FCC Part15B Class AEMS IEC61000-4-11DIPsIEC61000-4-2ESD:Contact:4kV;Air:8kVIEC61000-4-3RS:80MHz to1GHz:3V/mIEC61000-4-4EFT:Power:1kV;Signal:0.5kVIEC61000-4-5Surge:Power:1kVIEC61000-4-6CS:150kHz to80MHz:10V/m;Signal:10V/mIEC61000-4-8PFMFSafety EN60950-1,IEC60950-1,UL60950-1Vibration IEC60068-2-6DeclarationGreen Product RoHS,CRoHS,WEEEMTBFTime425,321hrsStandards Telcordia(Bellcore),GBWarrantyWarranty Period5yearsDetails See /warrantyPackage ContentsDevice1x IA240Series computerInstallation Kit1x DIN-rail kit1x wall-mounting kitCable1x DB9male to RJ458-pin1x Ethernet,crossover1x RJ45-to-DB9console cable1x terminal block to power jack converterPower Supply1x power adapter,universalDocumentation1x document and software CD1x product certificates of quality inspection,Simplified Chinese1x product notice,Simplified Chinese1x quick installation guide1x warranty cardDimensionsOrdering InformationModel Name Serial Ports LAN Ports DI/DO USB2.0Storage Slots Operating Temp. IA240-LX424/41SD Card-10to60°CIA240-T-LX424/41SD Card-40to75°C ©Moxa Inc.All rights reserved.Updated Jan22,2020.This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc.Product specifications subject to change without notice.Visit our website for the most up-to-date product information.。
SCA系列接口连接器240系列(SCA.1)说明书

s MATERIALSs SPECIFICATIONSsFEATURES•Half pitch connector conformed to SCA system (80pins).•Add mating guide and ESD protection to do plug-in safety and reliability (They are newly added on SCA.2CN).•Hot-plugging. Ground contacts mate first before other contacts mate when engagement is done (conforms to SCA.2 specification).•To prevent pin-bending, bellows contacts are used.•Plug: 2 types are available.1)The center of a SMT plug mates the center of a PCB.2)0.9 mm (0.035 in.) off-set from centerSpecifications–55°C to +105°C DC 1 A AC 240 V40 m Ω max. (DC 6 V, 0.1 A)1000 M Ω min. (DC 500 V)AC 750 V for 1 minuteItemOperating temperature range Current rating Voltage rating Contact resistance Insulation resistance Dielectric withstand voltage )ItemInsulator Conductor PlatingMaterialsPolyester (UL94V-0)Copper alloy Contact TerminalGold plating Palladium platingSCA.1, SCA. 2 INTERFACE CONNECTOR240 SERIES (SCA)DiscontinuedPLUG, SMT (STRADDLE MOUNT)sDIMENSIONSs PC BOARD MOUNTING PATTERNs PART NUMBERFCN-248Q080-L/BSPLUG, SMT [0.9 mm (0.035 in.) OFFSET]sDIMENSIONSs PART NUMBERFCN-248Q080-L/CSSOCKET, VERTICAL MOUNT s DIMENSIONSs PC BOARD LAYOUTs PART NUMBERFCN-244B080-G/ASPLUG, SMT (STRADDLE MOUNT), 20 PIN s DIMENSIONSs PC BOARD LAYOUTs PART NUMBERFCN-248Q020-L/ESs DIMENSIONS 80 -Ls PC BOARD LAYOUTPLUG, SMT (STRADDLE MOUNT) FIBER CHANNEL sDIMENSIONSs PART NUMBERFCN-248Q040-L/ES248Q Series SCA.2SINGLE SIDE SMT SCA.2s DIMENSIONSs PC BOARD LAYOUTs PART NUMBERFCN-248Q080-L/FSSOCKET, VERTICAL MOUNT FIBER CHANNEL sDIMENSIONSBW P D E D N E M M O C E R SS E N K C I H T R E B M U N T R A P T C A T N O C L A N G I S )A (H T G N E L T S O P T C A T N O C D S E )H G E L T S O P B (T N m m 8.0:T P S C /L -040B 442-N C F )470.0(88.1)470.0(88.1m m 6.1:T P S B /L -040B 442-N C F )011.0(97.2)601.0(07.2m m 0.2:T P S D /L -040B 442-N C F )321.0(21.3)321.0(21.3m m 4.2:T P S E /L -040B 442-N C F )421.0(41.3)631.0(54.3mm 2.3:T P SF /L -040B 442-N C F )061.0(60.4)861.0(72.4SOCKET, VERTICAL MOUNTs DIMENSIONSs PC BOARD MOUNTING PATTERN© 2007 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the prop-erty of their respective owners. Fujitsu Components America, Inc. or its affiliates do not warrant that the content of the datatasheet is error free. In a continuing effort to improve our products, Fujitsu Components America, Inc. or its affiliates reserve the right to change specifications/datasheets witout prior notice. Rev. November 2, 2007.JapanFujitsu Component Limited Gotanda-Chuo Building3-5, Higashigotanda 2-chome, Shinagawa-ku Tokyo 141-0022, Japan Tel: (81-3) 5449-7010Fax: (81-3) 5449-2626Email:********************.com Web: North and South AmericaFujitsu Components America, Inc.250 E. Caribbean DriveSunnyvale, CA 94089 U.S.A.Tel: (1-408) 745-4900Fax: (1-408) 745-4970Email:*********************.com Web: /componentsEuropeFujitsu Components Europe B.V.Diamantlaan 252132 WV Hoofddorp NetherlandsTel: (31-23) 5560910Fax: (31-23) 5560950Email:*****************.comWeb: /components Asia PacificFujitsu Components Asia Ltd.102E Pasir Panjang Road#01-01 Citilink Warehouse Complex Singapore 118529Tel: (65) 6375-8560Fax: (65) 6273-3021Email:*****************.com Fujitsu Components International Headquarter Offices。
Volvo 240 Turbo 发动机技术参数说明说明书

.Model I/Model
---2--4--0----T---u- r:-b---o--- ------------^iNr/iNn
,j I.J
«!
M O T O R /E N G IN E
65) Cylinderdiameter Bore
92 mm
60 1
115) A n ta l sittp la ste r__________ 5 _________________ Seating capacity
116) V ik t ____ 1 2 7 5 k g Weight
TILLBEHÔR OCH SÀTEN/ACCESSDRIES A N D UPHOLSTERY
sv:
IH - .
•^ T i r \ c
F.l.S.A. )
flUTOW
1196 mm
42. Steering ra tio
17,3:1
61. Thickness o f brake d is c , fro n t:
22,0 mm; re ar: 9,6 mm
62. Diameter of brake d is c , fro n t:
263 mm; re ar: 281 mm
T n fp g ra l
73) Antal ramlager for vevaxein
5
Number of crankshaft main bearings
69) Max. tillâten slagvolym Max. cylinder capacity allowed
71) Antal
1
Number
COMMTEST220和COMMTEST240数据收集器系统用户指南说明书

DescriptionCOMMTEST220and COMMTEST240are portable datacollector solutions that cater to non-hazardous environments.You can use these small form-factor,rugged devices to takevibration recordings and upload the collected data for detailedanalysis in System1*.The data collectors work in tandem with the S1Collector appwhich runs on an industrial smartphone hand-held device.Youcan collect vibration data,take pictures,send text messages,check your email,make phone calls and run other apps all onthe same hand-held device.The data collectors use Bluetooth to communicate with thehand-held device.The S1Collector app exchanges data withSystem1*using Wi-Fi,a cellular network,or a USB cable.You can set up your routes in System1*and sync up the datawith the app using remote communication servers.The industrial hand-held device eliminates the need for a PCor other software packages at the data collection site.It is theonly device you need to receive routes and send collected datafrom the field.You can take recordings from a predefined route as well asoff-route recordings that are not part of a route sequence.Off-route recordings may be necessary if a machine's vibrationpattern does not meet your expectations.The data collectors have a neck strap with Sensor Keeperwhich restrains your sensor while you walk or climb to reachother machines.The neck strap also has detachable safetybreakaways to protect you in case the cables are caught inrotatingmachinery.COMMTEST220&COMMTEST240Product DatasheetBently Nevada*Asset Condition MonitoringDocument:109M0792Document:109M0792Document:109M0792Document:109M0792Handheld Specificationsecom®Smart-Ex201-A Part Number111M5756ecom®Smart-Ex201-E Part Number109M8034Display 4"Gorilla Glass2 Glove touchMobile 4G/LTEQuad Band UMTS and GSMWiFi 802.11a/b/g/n Dual band WiFi Direct WiFiHotspotBlueTooth 4.0and LECameras 8MP back 1MP frontLight Camera flash LED torchSensors GPS NFCOS Android5.1CPU Quad core1.2GHzMemory 1GB RAM16GB internal storageBattery Li-Ion4800mAhUp to40hr talk timeSize 137x72x21mm 290gRuggedness IP68-20to55°CFor the latest specifications and ratings of these industrial hand-held devices,visit.The COMMTEST220and COMMTEST240 solutions include an industrial hand-held device that runs the Android operating system and uses USB,cellular,Bluetooth and Wi-Fi for communication.These solutions have features that reduce but do not eliminate cybersecurity risks.We strongly recommend implementing additional cybersecurity protections such as the following:n Controlling user accessn Scanning for virusesn Applying timely updatesn Encrypting datan Using mobile device management softwareThe recommended measures are at your discretion and responsibility.Some residual risk may remain.For more information on cybersecurity,see SCOUT200Series Installation and Operation Manual(109M1269-01).Document:109M0792For a detailed list of country and product-specificapprovals,refer to the Approvals Quick ReferenceGuide(108M1756)at .COMMTEST220-AXX-BXXA:Handheld Options00None01ecom Smart-Ex201-A(North America)02ecom Smart-Ex201-E(Europe)03Tab Active tabletB:Data Collector Approval Options00NoneThe overall hazardous system rating is defined by theminimum rating of the data collector,industrialhandheld and accessories.Metrology certification is available with yourorder.Basic KitWe offer COMMTEST220in a basic kit with theoption to purchase the System1*software andlicense separately.Additional accessories arealso available.Document:109M0792COMMTEST240-AXX-BXXA:Handheld Options00None01ecom Smart-Ex201-A(North America)02ecom Smart-Ex201-E(Europe)03Tab Active tabletB:Data Collector Approval Options00NoneThe overall hazardous system rating is defined by theminimum rating of the data collector,industrialhandheld and accessories.Metrology certification is available with yourorder.Basic KitWe offer COMMTEST220in a basic kit with theoption to purchase the System1*software andlicense separately.Additional accessories arealso available.Document:109M0792Language Specific Warning Labels110M9913Magnet base label110M9914Sensor keeper side label110M9915Sensor keeper front label111M7144Hard carrying case label Optional Accessories3071/01System1*software and license109M2387Handheld,battery-powered laser Tach for IS Zone1This item does not include a cable.You must order part number109M2389.109M2389 1.2-meter laser Tach cable for109M2387109M2391Laser Tach powered by SCOUT220-IS& SCOUT240-ISCBL502165-meter laser Tach cable for109M2391113M5529-01Reflective tapeOne roll,60cm(23.7in)111M5756ecom®Smart-Ex01-A109M8034ecom®Smart-Ex01-E113M9352-01ecom®TAB-EX US/EU113M9352-02ecom®TAB-EX AS/NZ113M9353-01Tab Active tabletDocument:109M0792Copyright2000-2018Baker Hughes,a GE Company,LLC("BHGE")All rights reserved.*Denotes a trademark of Bently Nevada,LLC,a wholly ownedsubsidiary of Baker Hughes,a GE company,a wholly ownedsubsidiary of Baker Hughes,a GE company.All product and company names are trademarks of their respectiveholders.Use of the trademarks does not imply any affiliation with orendorsement by the respective holders.The information contained in this document is subject to changewithout prior notice.1631Bently Parkway South,Minden,Nevada USA89423Phone:Document:109M0792。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
DMX512-DISCO240控制台
说
明
书
Ver 2.0/4.0
目录
一、参数指标-----------------------------------------------------------------------------1
二、安全使用注意事项-----------------------------------------------------------------1
三、装箱清单-----------------------------------------------------------------------------1
四、通讯电缆-----------------------------------------------------------------------------2
五、DMX 512地址分配----------------------------------------------------------------2
六、通讯电缆连线及电脑灯地址码拔码示意图-----------------------------------3
七、面板及功能区域指示图-----------------------------------------------------------4
八、面板功能区域说明-----------------------------------------------------------------4
九、双功能键的说明--------------------------------------------------------------------5
十、LCD液晶屏显示信息说明-------------------------------------------------------6 十一、电脑灯程序(场)的编辑--------------------------------------------------------7 十二、电脑灯程序的运行-----------------------------------------------------------------7 十三、特殊场景表现-----------------------------------------------------------------------8 十四、如何设置、取消摇滚杆电位器--------------------------------------------------8 十五、常规调光控制-----------------------------------------------------------------------8
非常感谢使用HENGDA系列电脑灯控制器!HD-DMX512-Disco 240控制台为国际标准DMX512信号输出。
在操作使用前,请仔细参阅说明书。
一、参数指标
二、安全使用注意事项
●控制台必须接安全大地线。
●应避免带电拔插通讯电缆。
●开机顺序:请先打开所有受控制的电脑灯电源,然后再打开控制器电源,否
则易损坏控制器。
●注意防潮湿、防水、防尘、防静电、定期维护清洁。
三、装箱清单
●HD-DMX512-Disco 240 控制台1台
●DMX 512 电缆1条
●HD-DMX512-Disco 240使用手册1本
●电源变压器1个
四、通讯电缆
●采用特征阻抗为120欧双绞屏蔽线,如电缆超过200米或灯数量较多,应加
信号提升放大器并在最后一台灯加接终端电阻(120欧姆/1W)。
●通讯电缆1脚为地(GND),2脚为信号正,不可接反接错。
●通讯电缆应单端接地屏蔽。
●通讯电缆应避免同强电一齐布线。
五、DMX 512地址分配
HD-DMX512-Disco 240控制台使用DMX 512的1-240通道,可控制16通道以内的电脑灯,地址分配
如下:
六、通讯电缆连线及电脑灯地址码拔码示意图
八、面板功能区域说明
九、双功能键区说明
十、LCD液晶屏显示信息说明
十一、
电脑灯程序(场)的编辑
1. 按[BLACK]键,使该LED 熄灭:
2. 扫[EDIT/RUN]键,使该LED 亮,进入编程状态:
3. 按数字(P1—P12)中任意键一次,选择要编程的程序(场)编号,显示在LCD 的Chase[ ]
中。
4. 再按数字(P1—P12)键,选择出受控的电脑灯,使用权之对应的LED 灯亮,若对应指示
灯不亮,则表示该灯未选中,不受第5步的影响。
5. 推动(CH1—CH8)调节电脑灯各对应通道数据,或按SA/SB 键,推动CH9—CHD16调
光对应的电脑灯效果(如果已经设置了X 、Y 运动方向扫描通道转移,则其中有两个直滑电位器推杆不起作用,您可操纵右下角摇摆电器获取数据。
) 6. 重复4、5步,调节其他电脑灯,使之所需电脑灯场景达到预定效果。
7. 推动[SPEED]、[CROSS]电位器,调节好场景停留时间及场景过渡时间。
8. 按[ + ,记忆此步场景效果,并进入下一步编辑。
(若按[ - ] 键,可查看上一步的场景,重复4、5、6、7步修改,再按[ + 贮存。
) 9. 重复4-8步,编辑其他场景(程序步)。
10.按[EDIT/RUN]键,使该对应指示灯熄灭,记忆并退出编辑状态,进入运行状态。
11.重复2-10步,编辑其他程序场。
十二、 电脑灯程序的运行
1. 按[EDIT/RUN]键,使该对应LED 灯熄灭。
2. 按数字键(P1-P12),选择程序(场)编号,使之运行,若该程序(场)未被编辑,则按此
键号时对应的LED 灯不亮。
3.调节[SPEED]及[CROSS]电位器,改变场景与场景之间的停留时间及场景渐变运行速度,若[SPEED]或[CROSS]电位器处于下部份AUTO区域,则自动运行已编辑好
的场景停留及场景过渡时间。
4.按[CROSS MODE]键,可转换运行模式,详见:九、双功能键区说明
5.若想执行手动或自动混合运行程序,则可按下述步骤设定运行。
a)首先释放通道:按[CHANNELS]键,再按(P1—P8)键(或按[SHIFT],再按PCH9—PCH16),
释放对应通道,把F变成O,最后再按[CHANNELS]键,记忆退出。
(F:代表该对应通道,
在程序运行中不、接收手动数据,受已编程序控制。
O:代表该对应通道在程序运行中,
已不再受程序控制,接受手动推子数据。
)
b)选好要运行释放通道的灯:按[MANUAL]键,再按(P1—P12)键,选出要执行手动控制
的灯号,随机推动相应已释放好的电位器推子,执行手动+自动混合运行程序,按[MANUAL]
退出手动选择。
6.按[BLACK]可使运行程序(场)做暂停/启动选择,对应键LED灯灭时则输出运行正常。
十三、特殊场景表现
在运行程序状态下(即[RUN/EDIT]键对应指示灯熄灭),按[RUN SCENE]键,再按P1—P12中任意键,可调出已编程的第1号程序场中的前12个场景,所以我们建议第1号程序场的前12个场景在编程时,最好有特殊定义,可作一些特技表演效果。
十四、如何设置、取消摇滚杆电位器
设置摇滚杆电位器设置:按[RUN/EDIT]键,使该指示灯点亮,紧接着按[SET X/Y]键,根据液晶屏的提示,从(P1-P8)或按SA/SB键,从(PCH9—PCH16)中选取出两个对应电脑灯X、Y运行方向的扫描通道,转移到胀摇滚杆电位器去控制绿色指示灯,随即点亮,如果输入错误,按[DELETE]键取消输入,重新键入正确的对应通道,再按[SET X/Y]键记忆退出。
取消摇滚杆电位器设置:在[SET X/Y]状态下,按[DELETE]清除输入数据,绿色指示灯随即熄灭,再按[SET X/Y]键记忆退出。
十五、常规调光控制
点控:按动P13-P24控制调光的206-217通道,指示灯亮时表示输出100%,指示灯灭时输出0%。
分控:在非编程状态下,按SCAN/LIGHT键使指示灯亮,进入调光状态,按SA/SB/SC选择调光控制的通道页面,推动推子区的各个推子调节调光输出。