EPB5038G中文资料
爱达顿电源分发单元G3 EMIB05系列说明说明书

Eaton EMIB05Eaton Metered Input rack PDU, 0U, 26U, Input IEC-60309 32A 1Ph, 7.4 kW max, 32A, 200-240V, Outlets 20XC13 : 4XC19General specificationsEaton metered input rack PDU EMIB057431720659021150 mm 52 mm 53 mm 4 kg 2 year CE Marked RoHS Compliant EAC CEIEC 60950-1 EN 55024:2010EPDU MI 0U (309 32A 1P)20XC13:4XC19Product NameCatalog Number UPCProduct Length/Depth Product Height Product Width Product Weight Warranty Compliances Certifications Model Code20Single-phase Connecting cord with plug Metric7.4 kW max0U (Vertical)Vertical32 AIEC-60309 32A 1PhDisplayAmpere Meter Mounting material50/60 Hz0° to 60°C (32° to 140°F) Yes Eaton ePDU G3 one-page overviewEaton ePDU G3 brochureEaton UPS Services Quick Guide 2021Eaton UPS and battery servicesEaton ePDU G3 - BrochureEaton RoHS Declaration of Conformity: ePDU G3EU Declaration of Conformity Eaton ePDUs G3Drawing EMIB05Eaton ePDU G3 EMP installation and connection quick start guide Eaton ePDU G3 operations manualEaton ePDU G3 replace and configure eNMC moduleEaton ePDU G3 - Installation and Connectivity Quick StartEaton ePDU G3 installation and connectivity quick start guide Eaton Double-wide G3 ePDU installation and connectivity quick start guideEaton ePDU G3 1U and 2U installation addendumEaton ePDU G3 instruction set - system objectsOptimizing rack power distributionQuick guide to power distributionNumber of Outputs C13PhaseElectrical connectionMounting dimension (standardized) WattageForm factorMounting directionAmperage RatingPackage contentsInput connectionFitted with:Frequency ratingOperating TemperatureEthernet interface BrochuresCertification reports Compliance information DrawingsManuals and user guides White papersRack PDUMounting accessories Network cable Configuration cable Splitter for daisy-chaining Quickstart guideSafety InstructionsNumber of outlets with earth pin24Circuit breaker(2) single-poleMass configurationYesCommunicationHTTP, HTTPS, SSL, Telnet, FTP, SNMP, SMTP, DNS, DHCP, LDAP, RADIUSSpecial featuresPhase Metering, CircuitBreaker Current Meteringand Input MeteringHot-Swap Control modulewith advanced LCDOptionalTemperature/HumiditysensorBuilt-in IEC outlet eGripretention, retains allstandard IEC plugsBuilt-in outlet P-lock system,locking mechanism with P-lock power cordsDaisy-Chain up to 8 PDUs,reduce networkinfratsructure costsPower chain monitoring &Real time Intelligence onyour Data Center, via EatonIntelligent Power Manager60°C Operating temperatureColour-coded outlet andbranch circuits for simpleload balancingHydraulic–Magnetic CircuitBreakers with accidental tripprotectionNumber of Outputs C194Outlet controlNoSwitchableEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All rights reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaNo 3m200-240V Black Yes Aluminium2(20) C13, (4) C19Rack PDU Yes52Cord length Input voltage Color SNMP Material Over voltage category OutletsType Serial interface Mounting Dimension (metrical)。
Moxa PT-G503 三口全GB接口冗余箱说明说明书

PT-G503SeriesIEC61850-3/62439-33-port full Gigabit managed redundancyboxesFeatures and Benefits•IEC61850-3,IEEE1613(power substations)compliant•IEC62439-3Clause4(PRP)and Clause5(HSR)compliant•PRP/HSR Coupling and QuadBox functions supported•Ethernet console reserved for local access•Built-in MMS server based on IEC61850-90-4switch data modeling forpower SCADA•Hardware-based IEEE1588v2PTP supported•Design ready for NERC CIP compliant system development•Isolated redundant power inputs with universal24VDC,48VDC,or110/220VDC/VAC power supply range•-40to85°C operating temperature rangeCertificationsIntroductionThe PT-G503-PHR-PTP Series redundancy boxes(RedBoxes)are compliant with the latest standardized redundancy protocols for industrial automation networks,IEC62439-3Clause4(Parallel Redundancy Protocol,PRP)and IEC62439-3Clause5(High-availability Seamless Redundancy,HSR).PRP/HSR ensures the highest system availability and data integrity for mission-critical applications in electrical substation and/or process automation systems that require zero recovery time redundancy.The redundant protocols Coupling and QuadBox are also supported.With Coupling and QuadBox,HSR rings can be connected to make the redundant network more versatile.The PT-G503-PHR-PTP Series comes with three10/100/1000BaseT(X)and100/1000BaseSFP slot combo ports.One slot(INTERLINK port)is for an internal link for connecting with a SAN(Singly Attached Node).The other two ports(LAN A and LAN B ports)are for PRP/HSR redundant protocol communications.With this full Gigabit Ethernet port design,the PT-G503-PHR-PTP Series provides high performance for PRP/HSR systems.The PT-G503-PHR-PTP Series also provides IEEE1588v2PTP in end-to-end one-step transparent clock mode for timing-critical applications and isolated redundant power inputs with24/48VDC or110/220VDC/VAC power supply ranges to increase the reliability of the power supply. Additional Features and Benefits•PRP(Parallel Redundancy Protocol):Transmit or receive two independent active paths to/from different LANs simultaneously on a zero recovery time network•HSR(High-availability Seamless Redundancy):Every frame is duplicated and then transmitted in both directions of the HSR ring to deliver zero switchover time•PRP/HSR coupling:Supports coupling from an HSR ring node to redundant PRP LANs(Up to7PRP LANs)•QuadBox function:Supports peer coupling of rings via interconnecting two INTERLINK ports on two separate RedBoxes •Fiber Check™provides monitoring and diagnosis functionality on SFP fiber ports•Hardware-based IEEE1588v2PTP(Precision Time Protocol)end-to-end one-step transparent clock for precise time synchronization of networks•Automatic warning by exception through email and relay output •Configurable via web browser,CLI,Windows utility,and ABC-02 automatic backup configuratorSpecificationsEthernet Interface3Combo Ports(10/100/1000BaseT(X)or100/1000BaseSFP+)Console Port Ethernet console(10/100/1000Mbps RJ45)Standards IEEE802.3for10BaseTIEEE802.3ab for1000BaseT(X)IEEE802.3u for100BaseT(X)and100BaseFXIEEE802.3z for1000BaseSX/LX/LHX/ZXEthernet Software FeaturesFilter Static MulticastIndustrial Protocols Modbus TCPManagement Back Pressure Flow Control,BOOTP,DHCP Client,Fiber check,Flow control,HTTP,IPv4/IPv6,LLDP,Port Mirror,RARP,RMON,SMTP,SNMP Inform,SNMPv1/v2c/v3,Syslog,TelnetPower Substation MMSRedundancy Protocols HSR,PRP,RSTP groupingSecurity HTTPS/SSL,TACACS+,RADIUS,SSH,Trust access controlTime Management NTP Server/Client,SNTP,IEEE1588v2PTP(hardware-based)MIB IEC62439-3MIBUSB InterfaceStorage Port USB Type ASerial InterfaceConsole Port USB-serial console(Type B connector)Input/Output InterfaceAlarm Contact Channels Resistive load:1A@24VDCDigital Inputs+13to+30V for state1-30to+3V for state0Max.input current:8mAPower ParametersInput Voltage PT-G503-PHR-PTP-HV:Redundant dual inputs110/220VAC/VDC(85to264VAC,88to300VDC)PT-G503-PHR-PTP-WV:Redundant dual inputs24/48VDC(18to72VDC)Overload Current Protection SupportedReverse Polarity Protection SupportedInput Current PT-G503-PHR-PTP-HV:0.260/0.170A@110/220VACPT-G503-PHR-PTP-HV:0.150/0.080A@110/220VDCPT-G503-PHR-PTP-WV:0.660/0.360A@24/48VDCPower Connector1removable5-contact terminal block(s)Physical CharacteristicsHousing AluminumIP Rating IP40Dimensions(without ears)80x160x110mm(3.15x6.30x4.33in)Weight1210g(2.69lb)Installation DIN-rail mountingEnvironmental LimitsOperating Temperature-40to85°C(-40to185°F)Storage Temperature(package included)-40to85°C(-40to185°F)Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsSafety UL508EMI EN55032Class A,CISPR32,FCC Part15B Class AEMS IEC61000-4-2ESD:Contact:8kV;Air:15kVIEC61000-4-3RS:80MHz to1GHz:35V/mIEC61000-4-4EFT:Power:4kV;Signal:4kVIEC61000-4-5Surge:Power:4kV;Signal:4kVIEC61000-4-6CS:10VIEC61000-4-8PFMFIEC61000-4-11DIPsPower Substation IEC61850-3,IEEE1613Railway EN50121-4MTBFTime PT-G503-PHR-PTP-HV:566,844hrsPT-G503-PHR-PTP-WV:440,857hrsStandards Telcordia(Bellcore)Standard TR/SRWarrantyWarranty Period5yearsDetails See /warrantyPackage ContentsDevice1x PT-G503Series switchCable1x USB type A male to USB type B maleInstallation Kit1x DIN-rail kit1x cap,for type A USB port4x cap,plastic,for RJ45port1x cap,plastic,for console port3x cap,plastic,for SFP slotDocumentation1x document and software CD1x quick installation guide1x warranty card1x product certificates of quality inspection,Simplified Chinese1x product notice,Simplified ChineseNote SFP modules need to be purchased separately for use with this product.DimensionsOrdering InformationModel Name Max.No.of Ports Max.No.of GigabitPortsCombo Ports10/100/1000BaseT(X)or100/1000BaseSFPInput Voltage Operating Temp.PT-G503-PHR-PTP-WV33324/48VDC-45to85°C PT-G503-PHR-PTP-HV333110/220VDC/VAC-45to85°CAccessories(sold separately)SoftwareMXview Industrial network management software designed for converged automation networksSFP ModulesSFP-1FELLC-T SFP module with1100Base single-mode with LC connector for80km transmission,-40to85°Coperating temperatureSFP-1FEMLC-T SFP module with1100Base multi-mode with LC connector for4km transmission,-40to85°Coperating temperatureSFP-1FESLC-T SFP module with1100Base single-mode with LC connector for40km transmission,-40to85°Coperating temperatureSFP-1G10ALC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for10km transmission;TX1310nm,RX1550nm,0to60°C operating temperatureSFP-1G10ALC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for10km transmission;TX1310nm,RX1550nm,-40to85°C operating temperatureSFP-1G10BLC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for10km transmission;TX1550nm,RX1310nm,0to60°C operating temperatureSFP-1G10BLC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for10km transmission;TX1550nm,RX1310nm,-40to85°C operating temperatureSFP-1G20ALC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for20km transmission;TX1310nm,RX1550nm,0to60°C operating temperatureSFP-1G20ALC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for20km transmission;TX1310nm,RX1550nm,-40to85°C operating temperatureSFP-1G20BLC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for20km transmission;TX1550nm,RX1310nm,0to60°C operating temperatureSFP-1G20BLC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for20km transmission;TX1550nm,RX1310nm,-40to85°C operating temperatureSFP-1G40ALC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for40km transmission;TX1310nm,RX1550nm,0to60°C operating temperatureSFP-1G40ALC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for40km transmission;TX1310nm,RX1550nm,-40to85°C operating temperatureSFP-1G40BLC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for40km transmission;TX1550nm,RX1310nm,0to60°C operating temperatureSFP-1G40BLC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for40km transmission;TX1550nm,RX1310nm,-40to85°C operating temperatureSFP-1GEZXLC SFP module with11000BaseEZX port with LC connector for110km transmission,0to60°C operatingtemperatureSFP-1GEZXLC-120SFP module with11000BaseEZX port with LC connector for120km transmission,0to60°C operatingtemperatureSFP-1GLHLC SFP module with11000BaseLH port with LC connector for30km transmission,0to60°C operatingtemperatureSFP-1GLHLC-T SFP module with11000BaseLH port with LC connector for30km transmission,-40to85°C operatingtemperatureSFP-1GLHXLC SFP module with11000BaseLHX port with LC connector for40km transmission,0to60°C operatingtemperatureSFP-1GLHXLC-T SFP module with11000BaseLHX port with LC connector for40km transmission,-40to85°Coperating temperatureSFP-1GLSXLC SFP module with11000BaseLSX port with LC connector for500m transmission,0to60°C operatingtemperatureSFP-1GLSXLC-T SFP module with11000BaseLSX port with LC connector for500m transmission,-40to85°Coperating temperatureSFP-1GLXLC SFP module with11000BaseLX port with LC connector for10km transmission,0to60°C operatingtemperatureSFP-1GLXLC-T SFP module with11000BaseLX port with LC connector for10km transmission,-40to85°C operatingtemperatureSFP-1GSXLC SFP module with11000BaseSX port with LC connector for300/550m transmission,0to60°Coperating temperatureSFP-1GSXLC-T SFP module with11000BaseSX port with LC connector for300/550m transmission,-40to85°Coperating temperatureSFP-1GZXLC SFP module with11000BaseZX port with LC connector for80km transmission,0to60°C operatingtemperatureSFP-1GZXLC-T SFP module with11000BaseZX port with LC connector for80km transmission,-40to85°C operatingtemperature©Moxa Inc.All rights reserved.Updated Nov12,2018.This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc.Product specifications subject to change without notice.Visit our website for the most up-to-date product information.。
YAV 8AD PRO 24位高精度串口多功能采集卡技术手册DAM7452

YAV8AD PRO高精度串口采集卡技术手册V1801武汉亚为电子科技有限公司DAM7452关于本手册为亚为推出的YAV8AD PRO数据采集卡的用户手册,主要内容包括功能概述、8路模拟量输入功能、8路IO功能、应用实例、性能测试、注意事项及故障排除等。
说明序号版本号编写人编写日期支持对象应用时间特别说明1 1.0郑先科2014.05YA V8AD PRO采集卡2 2.0郑先科2016.01YA V8AD PRO采集卡3 3.0郑先科2017.01YA V8AD PRO采集卡2017.01适用于RS232\485\WiFi\GPRS ZIGBEE\蓝牙\433M无线4 4.0李雪2017.08YA V8AD PRO采集卡2017.08目录0.快速上手 (1)产品包装内容 (1)应用软件 (1)接口定义 (1)通信 (2)1.产品概述 (2)技术指标 (2)⏹模拟信号输入 (3)⏹数字信号输入 (4)⏹数字信号输出 (4)⏹通信总线 (4)⏹温度参数 (4)硬件特点 (5)原理框图 (5)机械规格 (6)2.采集卡信号接线 (7)AI模拟量接线 (7)DI数字量接线 (8)DO数字量接线 (9)3.模拟量输入功能 (9)模拟量输入 (9)输入采样原理 (10)输入接线 (10)采样值计算 (11)⏹无符号整型 (11)⏹24位精度采集值的计算方法 (11)⏹模拟量值 (12)4.数字量输入功能 (12)数字量输入原理 (12)DI高低电平/无源触点输入 (13)计数功能输入 (13)测频功能输入 (13)PWM功能输入 (13)5.数字量输出功能 (14)输出原理 (14)DO高低电平输出 (14)PWM测试输出 (14)AO输出 (14)输出接线方式 (15)6.通信协议 (15)串口Modbus通信协议 (15)YA V IOT通信协议 (17)7.应用实例 (19)采集卡连接 (19)软件功能 (20)⏹亚为串口采集卡通用采集平台 (21)8.注意事项及故障排除 (22)注意事项 (22)⏹存储说明 (22)⏹出货清单 (22)⏹质保及售后 (22)⏹特别说明 (22)故障排除 (23)⏹无法正常采集数据 (23)⏹不显示波形 (24)⏹DI测频计数没反应 (24)⏹采集速度不够 (24)⏹软件错误 (24)9.性能测试 (24)安全规范 (24)耐电压范围测试 (25)环境适应性测试 (25)10.文档权利及免责声明 (26)11.联系方式.......................................................................................................................错误!未定义书签。
2N5038资料

ICEO IEBO
µAdc µAdc µAdc
2N5038 2N5039
ICEX
6 Lake Street, Lawrence, MA 01841 1-800-446-1158 / (978) 794-1666 / Fax: (978) 689-0803
120101 Page 1 of 2
元器件交易网
MAXIMUM RATINGS Ratings
Collector-Emitter Voltage Collector-Base Voltage Emitter-Base Voltage Base Current Collector Current Total Power Dissipation @ TC = +250C (1) Operating & Storage Temperature Range
元器件交易网
TECHNICAL DATA
NPN HIGH POWER SILICON TRANSISTOR
Qualified per MIL-PRF-19500/439 Devices 2N5038 2N5039 Qualified Level JAN JANTX JANTXV
pF
SWITCHING CHARACTERISTICS
Turn-On Time VCC = 30 ± 2 Vdc; IC = 12 Adc; IB1= 1.2 Adc VCC = 30 ± 2 Vdc; IC = 10 Adc; IB1= 1.0 Adc Turn-Off Time VCC = 30 ± 2 Vdc; IC = 12 Adc; IB1 = -IB2 = 1.2 Adc VCC = 30 ± 2 Vdc; IC = 10 Adc; IB1 = -IB2 = 1.0 Adc 2N5038 2N5039 2N5038 2N5039
艾膘力保守SB窄型800A电源电路保护器说明书

Eaton SPN4083HEAXX2CEaton Power Defense SB, Narrow, 800 A, 42 kA, 3-Pole, Fixed,PXR20LSIG,General specificationsEaton Magnum low voltage power circuitbreakerSPN4083HEAXX2C78668973028414.6 in16.8 in12.5 in95 lbSABA ListedCE Marked CCC Marked NEMA Compliant DNV GL CertifiedCSA CertifiedANSIABS CertifiedUL ListedKEMA CertifiedLloyd's Register CertifiedProduct Name Catalog NumberUPCProduct Length/Depth Product Height Product Width Product Weight Compliances Certifications800 AUL 891NarrowThree-polePower Defense SB UL 891 Narrow Magnum PXR20Fixed Three-pole800 A 600 VAC Fixed 42 kA42 kA 800 A 800 A 600 VAC Zone selective interlocking application paperMagnum circuit breakers with Power Xpert Release trip units product aid Selevctive coordination application paper - IA0120000E3Magnum PXR and PD-SB standard and narrow frame UL Certificate of ComplianceMagnum PXR and PD-SB double and double narrow frame UL Certificate of ComplianceAmperage Rating Application FrameNumber of poles Type Application FrameSeriesTrip TypeMounting Method Number of polesRated uninterrupted current (Iu) Voltage rating Mounting Method Interrupt ratingInterrupt ratingAmperage RatingRated uninterrupted current (Iu) Voltage rating Application notes Brochures Catalogs Certification reportsEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaMagnum PXR low voltage power circuit breakers user manual Power Xpert Release trip unit for Magnum PXR circuit breakers PXR 20/25 user manualMicrosoft Word - Power Xpert Protection Manager Quick Start Guide.docxPower Xpert Protection Manager x64 22.6 1 Power Xpert Protection Manager x32 22.06 1 Eaton Specification Sheet - SPN4083HEAXX2C Low voltage circuit breakers guide spec Magnum PXR 20/25 electronic trip units time current curves Molded case and low-voltage power circuit breaker health Cyber security white paperSafer by design: arc energy reduction techniquesManuals and user guidesSoftware, firmware, and applications Specifications and datasheetsTime/current curvesWhite papers。
通用高清行管和大功率三极管主要参数表

常用高清行管和大功率三极管主要参数表2010-03-02 10:33:54 阅读78 评论0 字号:大中小高清彩电行管损坏的原因及代换现在,大屏幕彩色电视大都是数字高清,原来50Hz的场扫描频率接近人眼感知频闪的临界点,所以高清电视都是提高扫描频率来提高图像的清晰度,即将场扫描提高到100Hz或是60Hz逐行,这样就会使行扫描的频率提高一倍,自然行输出管的开关速度和功耗都会随之增加,普通的行输出管已经不能胜任,要采用性能更好的大功率三极管。
目前采用的行管有:C5144、C5244、J6920、C5858、C5905等,这些行输出管的耐压都在1500V以上,电流多大于20A,但是由于其功耗比较大,损坏率还是比较高。
归纳起来,其损坏的原因一般有以下六种。
1. 行激励不足如果行激励不足,行管不能迅速截止与饱和,导致行管内阻变大,将造成行输出电路的功耗增加,引起行输出管发烫,一旦超过行管功耗的极限值,便会使行管烧坏。
在海信高清电视中,行振荡方波信号是由数字变频解码板输出,经过一对三极管2SC1815、2SA1015放大后,送到行激励管的基极。
这两个三极管工作在大电流开关状态,故障率相对较高,损坏后就会造成行激励不足,损坏行输出管,对比可以用示波器测量行管基极的波形来确定。
另外,行管基极的限流电阻阻值一般为0.1Ω,与行管的发射极串联,再与行激励变压器并联,若是阻值增大有可能用普通万用表测不出来。
我们曾经修过多例次电阻增值到2Ω以上而导致开机几分钟后行管损坏的故障,且损坏行管的比例较大。
2. 行逆程电压过高在行逆程期间,偏转线圈会对逆程电容充电,逆程电容容量大小决定充电的时间。
容量越小,充电时间越短,充电电压越高,因而会产生很高的反峰脉冲电压。
所以,当行一旦超过行管的耐压值,就会出现屡烧行管的结果。
我们在测量逆程电容时,一般是测量电容的直流参数,而一些ESR等交流参数无法测量,所以最好是代换较可靠。
3. 行偏转线圈或行输出变压器局部短路造成行负责过重常见场输出集成电路击穿导致行偏转线圈或行输出变压器绝缘性能下降,产生局部短路、行输出逆程电容漏电等。
ABBG产品介绍0328

目录
产品概览主要功能系统拓扑图调试说明
| Slide
产品概览
室内机
产品概览主要功能系统拓扑图调试说明可视室内机G3251可视门口机辅助设备
New
象牙白
宝石蓝
拉菲红
富贵黑
香槟金
泰坦银
基本+8防区+信息发布
7“TFT
| Slide
产品概览
室内机
产品概览主要功能系统拓扑图调试说明可视室内机G3261G3262可视门口机辅助设备
| Slide
主要功能
门口机
产品概览主要功能系统拓扑图调试说明可视室内机可视门口机GC5809D-C辅助设备
性能说明高亮LED夜间照明、LED夜光键盘软件升级接口内置感应卡读卡门禁技术参数工作电压:DC 30~35V静态电流:≤70mA 工作电流:≤180mA摄像头:1/4”彩色 HD CMOS ,可视角度72°环境温度:-40~+70℃湿度:10%~95%射频频率:ID卡:125KHz 读卡类型:EM外壳材料:不锈钢外型尺寸:272×150×68.5mm安装方式:平装墙体安装尺寸:垂直孔距60mm接口类型:RJ45
| Slide
主要功能
室内机
产品概览主要功能系统拓扑图调试说明可视室内机GC3120-C可视门口机辅助设备
性能说明对讲、开锁、监视功能呼叫管理中心、紧急求助功能技术参数工作电压:DC 30~35V静态电流:≤25mA工作电流:≤250mA显示屏幕:4”CRT ,>450线 环境温度:-10~+55℃湿度:10%~95%外壳材料:塑料外型尺寸:203.4×221.5×63.2mm安装方式:壁挂式安装尺寸:水平中心孔距60mm接口类型:直插式RJ45转接线
UPG503B资料

FEATURES •WIDE OPERATING FREQUENCY RANGE: f IN = 3.5 to 9.0 GHz (T A = 25°C)•DIVISION RATIO OF 4•GUARANTEED OPERATING TEMPERATURE RANGE:-25°C to +75°CINPUT POWER vs. INPUT FREQUENCYELECTRICAL CHARACTERISTICS 1 (T A = 25°C, V DD = 3.8 V, V SS1 = 0 V, V SS2 = -2.2 V)I n p u t P o w e r , P I N (d B m )Input Frequency, f (GHz)0 1 2 3 4 5 6 7 8 9 10+10-10DESCRIPTIONThe UPG503B is a GaAs divide-by-4 prescaler that is capable of operating up to 9 GHz. It is designed to be used in the frequency synthesizers of microwave communication sys-tems and measurement equipment. The UPG503B is a dynamic divider. It employs buffered FET logic (BFL). The UPG503B is available in a hermetic 8-lead ceramic flat package.PART NUMBER UPG503B PACKAGE OUTLINEBF08SYMBOLSPARAMETERS AND CONDITIONSUNITS MIN TYP MAX I DD Supply CurrentmA 4080130I SS1Sink Current 2 I SS1 = I DD - I SS2mA 27I SS2Sink Current 2mA 215393f IN(U)Upper Limit of Input Frequency, P IN = +9 to +10 dBm GHz 8.69.0f IN(L)Lower Limit of Input Frequency, P IN = +9 to +10 dBm GHz 3.53.7P IN Input Power, f IN = 3.7 to 8.6 GHzdBm 9.010.0f IN = 5.0 to 7.4 GHzdBm 3.010.0P OUT Output Power,f IN = 8.6 GHz, P IN = +10 dBmdBm 03f IN = 3.7 GHz, P IN = +10 dBm dBm 03R THThermal Resistance, Channel to Case°C/W10Note:1.Device may exhibit low frequency spur typically below 150 Hz and -45 dBm.2. Current is positive into the I DD pin and returns through the I SS1 and I SS2 pins.California Eastern LaboratoriesUPG503BSYMBOLS PARAMETERS UNITS RATINGSV DD-V SS1Supply Voltage V 5.0V SS2-V SS1Supply Voltage V -5.0P IN Input PowerdBm 13P T Total Power Dissipation 2W 1.5T STG Storage Temperature °C -65 to +175T CCase Temperature°C-65 to +125Notes:1. Operation in excess of any one of these conditions may result in permanent damage.2. T C ≤ 125°C2.52.01.51.00.50050100150200250110POWER DERATING CURVET o t a l P o w e r D i s s i p a t i o n , P T (W )OUTPUT POWER vs. INPUT FREQUENCY101001K10K100KOffset from Carrier (Hz)S S B P h a s e N o i s e (d B c /H z )-60-70-80-90-100-110-120-130-140-150-1601M12456Input Frequency, f IN (GHz)O u t p u t P o w e r , P O U T (d B m )3+107-108910SSB PHASE NOISE VS.OFFSET FROM CARRIER f IN = 6.82 GHz, T A = 25°CTYPICAL PERFORMANCE CURVES (T A = 25°)Case Temperature, T C (°C)PART NUMBER UPG503B PACKAGE OUTLINEBF08SYMBOLSPARAMETERS AND CONDITIONSUNITS MINTYP MAXI DD Supply CurrentmA 80I SS1Sink Current 1 I SS1 = I DD - I SS2mA 27I SS2Sink Current 1mA 53f IN(U)Upper Limit of Input Frequency, P IN = +9 to +10 dBm GHz 8.0f IN(L)Lower Limit of Input Frequency, P IN = +9 to +10 dBm GHz 4.0P IN Input Power, f IN = 4.0 to 8.0 GHz dBm 9.010.0f IN = 5.0 to 7.0 GHzdBm 4.010.0P OUTOutput Power f IN = 8.0 GHz, P IN = +10 dBm dBm -1.0 2.0f IN = 4.0 GHz, P IN = +10 dBmdBm-1.0 2.0ELECTRICAL CHARACTERISTICS T A = 25°C to +75°C, V DD = 3.8 V, V SS1 = 0 V, V SS2 = -2.2 V)Note:1. Current is positive into the I DD pin and returns through the I SS1 and I SS2 pins.ABSOLUTE MAXIMUM RATINGS 1 (T A = 25°C)* V SS1 should be connected to GND through a 2.2 V Zener Diode (RD2.2FB or IN3394).V DDV SS1 = 0 V (GND)V SS2 = –2.2 VV DD V SS2 = 0 V (GND)C: 1000 - 5000 pF Chip CapacitorCONFIGURATION 2Single Positive Bias SupplyCONFIGURATION 3Single Negative Bias SupplyC: 1000 - 5000 pF Chip CapacitorV DD V SS2 = –6 VC: 1000 - 5000 pF Chip CapacitorCONFIGURATION 12 Bias Supply* For V SS1, the bias voltage of -6.0 should be applied through a 2.2 VZener Diode (RD2.2FB or IN3394).POWER SUPPLY CONFIGURATIONS (V GG1 and V GG2 are normally open)Notes:1. Because of the high internal gain and gain compression of the UPG503B, the device is prone to self-oscillation in the absence of an RF input signal. This self-oscillation can be suppressed by either of the following means:•Add a shunt resistor to the RF input line. Typically a resistor value between 50 and 1000 ohms will suppress the self-oscillation (see the test circuit schematic).•Apply a negative voltage through a 1000 ohm resistor to the normally open V GG1 connection. Typically voltages between 0 and -9 volts will suppress the self-oscillation.Both of these approaches will reduce the input sensitivity of the device (by as much as 3 dB for a 50 ohm shunt resistor), but otherwise have no effect on the reliability or electrical characteristics of the device.INV SS2OUTINDD OUTINV SS2DD OUTUPG503B1.OUTPUT2.V SS13.NC*4.V DD5.INPUT6.V GG17.V GG28.VSS2OUTLINE DIMENSIONS (Units in mm)UPG503BPACKAGE OUTLINE BF08* No ConnectionLEAD CONNECTIONS:EXCLUSIVE NORTH AMERICAN AGENT FOR RF, MICROWAVE & OPTOELECTRONIC SEMICONDUCTORS• Headquarters • 4590 Patrick Henry Drive • Santa Clara, CA 95054-1817 • (408) 988-3500 • Telex 34-6393 • FAX (408) 988-0279PRINTED IN USA ON RECYCLED PAPER -4/97DATA SUBJECT TO CHANGE WITHOUT NOTICE元器件交易网。