CELL A RXAPI:MO=RXOTG-0,DEV=RBLT-1&&-18,DCP=1&&18; RXMOI:MO=RXOTG-0,COMB=HYB,RSITE=CELLA; RXMOI:MO=RXOCF-0,TEI=62; RXMOI:MO=RXOIS-0; RXMOI:MO=RXOTF-0,TFMODE=SA; RXMOI:MO=RXODP-0-0,DEV=RXODPI-0; RXMOI:MO=RXOTRX-0-0,TEI=0,DCP1=128,DCP2=129&130; -------------------------RXMOI:MO=RXOTRX-0-5,TEI=5,DCP1=143,DCP2=144&145; CELL B RXAPI:MO=RXOTG-1,DEV=RBLT-19&&-27&RBLT-51&&-59,DCP=19&&27 &51&&59; RXMOI:MO=RXOTG-1,COMB=HYB,RSITE=CELLB; RXMOI:MO=RXOCF-1,TEI=61; RXMOI:MO=RXOIS-1; RXMOI:MO=RXOTF-1,TFMODE=SA; RXMOI:MO=RXODP-1-0,DEV=RXODPI-1; RXMOI:MO=RXOTRX-1-0,TEI=0,DCP1=128,DCP2=129&130; -------------------------RXMOI:MO=RXOTRX-1-5,TEI=5,DCP1=143,DCP2=144&145;

OMT软件故障代码

OMT软件故障代码

第三代(3G)LAS字号:大大中中小小OMT软件故障代码RBS2000 故障代码的描述(R7.1版本)绪论:BTS的故障是按故障的起因和重要性进行分类的:§1A级:MO内的故障,它会影响MO的功能特性.§1B级:MO外的故障,它也会影响MO的功能特性.§2A级:MO内的故障,它不会影响MO的功能特性.BSC要接收以上的BTS故障报告,应采用下列措施:§1A级: MO退出操作和测试.- 如果测试结果表明MO没有故障,那么MO将返回操作状态,并且其故障以间歇性故障处理.故障计数器将对间歇性故障进行累加,当发生间歇性故障的次数太高时,MO将会永久地退出工作状态.- 如果测试结果表明MO有故障,那么MO将永久地退出工作状态,直到故障停止或人工干涉才能恢复正常状态. 在BSC/OSS上将会产生一个A2告警.§1B级: MO将永久地退出工作状态,直到故障停止或人工干涉才能恢复正常状态. 在BSC/OSS 上将会产生一个A2告警.§2A级:在BSC/OSS上将会产生一个A2或A3告示警. 但MO仍处于工作状态.应注意的是:CF或TRXC上的2A级故障在从属MO中却被认为是1级故障.总是在CF/TRXC上读取RU的故障映象来进行故障定位.但有时应紧记要替换的被检测到的故障单元,以便更换.BTS的故障信息可以从BSC上或站上OMT接口用人机命令MML来获得。

§从BSC上获得:- 在MO中所有激活的告警: RXASP:MO=RXO…;- 在TG中所有激活的故障(1级): RXMFP:MO=RXOTG-x,FAULTY,SUBORD;- 在MO中所有激活的故障: RXMFP:MO=RXO…;- MO的故障记录: RXELP:MO=RXO…;§从OMT上获得:- 在TG中所有激活的故障: ”Syst em view(系统视图) / 选择RBS 2000 / Operations操作(或按右键) / Monitor(监视)/ Fault status(故障状态)”- 某个RU的故障记录: ”Hardware view(硬件视图) /选择RU / Operations操作(或按右键) / Save log(保存记录)” (只有DXU, TRU和ECU才有记录区).如果在CF/TRXC上产生RU单元的故障映象,其上的红灯将会发亮. 但这不一定就指此单元一定有故障,这也可能指此单元检测到其他单元有故障。

RBS2000硬件故障排查流程

RBS2000硬件故障排查流程
RBS2000硬件 故障排查方法
硬件故障排查方法
一、MO结构 二、硬件故障排查方法 三、硬件故障排查常用指令集
MO结构
一、MO结构
RBS200 MO:RXETG、RXETRX、RXETF、RXETX、RXERX、 RXETS
RBS2000 MO:RXOTG、 RXOCF、RXOCON、RXOIS、 RXOTF、 RXOTRX、RXOTX、RXORX、RXOTS
日常硬件故障排查
二、硬件故障排查方法
1) 日常硬件故障排查 • 根据日常指标统计中的突发下行质差较大、切换率较低、上行ICM 较大或其它指标的突发性异常情况作为故障排查的切入点进行硬件故障 的排查工作。在确定指标异常的小区后,按以下步骤进行硬件故障的排 查: • a.连接所属BSC
日常硬件故障排查
日常硬件故障排查
指令:RXELP:MO=RXOCF-XXX; 功能:查看该MO是否有历史告警 (输出结果全为零表示当前小区没有历史告警或已清空。输出结果 “MO”项可知是哪个MO故障,从输出结果的1AMAP、2AMAP查看是否 存在历史告警,且该告警多由硬件故障引起;从输出结果1BMAP、 EXT1BMAP、EXT2BMAP查看是否存在 历史告警时,该类告警记录传 输设备、时钟同步单元告警)
硬件故障排查常用指令集
RXASP:MO=RXOTG- ;查看该TG所有激活的MO告警,再用RXMFP查 看故障代码 RXMFP:MO= ;查故障代码(RXMFP:MO=RXOCF-*;还可查看DXU版 本,CDU类型等) RXELP:MO= ;打印MO历史告警。
干扰比例 98.77% 8.76% 2.78% 2.75% 1.72% 1.26% 0.92% 0.68%
变频区域硬件故障排查

爱立信基站典型故障处理案例

爱立信基站典型故障处理案例
在确认马厂湖基站的数据存在掉死的情况后,重新定义了新的TG数据,来替换原先存在掉死现象的TG数据,整个基站恢复正常运行。
对上述基站数据掉死的解决办法还有一种是进行BSC的重新启动,因为需要在晚上进行,因此可能会导致基站退服的时间较长。
案例4:中国银行基站第2小区对应的机架为2个CDU C,4个载频配置,总是在4个载频全部开起来后,又很快全部退服,现象为第1、2个TRU状态为TX not enabled,第3、4个TRU为Fault灯和Operational灯同时亮。每次对DXU进行复位,总是出现上述的同样现象,整个小区无法正常运行。
总结:针对多机架级联的基站,第2、3小区退服的情况,要考虑前一级级联的小区所在的机架是否存在DXU故障、PCM传输电缆接错、IDB数据中未定义PCM级联等情况。
案例7:某个基站第2小区有3个时隙LMO状态为0800,复位和更换载频后无效。
检查基站的定义数据,发现第2小区对应的TG-139,在定义半永久连接关系时,将RBLT-1309与DCP 28连接是错误的,导致DCP 28相对应的4个TS时隙,无法正常工作。应该是RBLT-1308与DCP 28连接,正确修改后,故障解除。
因为第3、4个TRU总是出现故障现象,将这两个TRU更换,仍然出现同样的故障现象;更换第3、4个TRU对应的第2个CDU C,仍然出现同样的故障现象。
将第3、4个TRU放到第5、6个TRU的位置上,将第2个CDU放到第3个CDU的位置,这样载频的位置为第1、2、5、6,甩开TRU第3、4位置不使用,整个小区正常运行,不再出现上述故障现象。
首先全面检查基站硬件、传输设备、传输电缆等均没有发现问题,检查柳行头基站数据、小区数据定义也没有发现问题,更换DXU也不能解决问题。

爱立信RBS2000系列基站的故障处理

爱立信RBS2000系列基站的故障处理

爱立信RBS2000系列基站的故障处理[摘要]本文介绍了RBS2000基站维护工作中常见的和有代表性的一些问题,包括:电源单元故障及处理方法,分集接收丢失告警的原因及处理方法,驻波比(V SWR)检测丢失告警的原因及处理方法,传输故障原因及处理方法,TRU故障原因及处理方法等。

[关键词]基站维护;故障处理;RBS2000;网络维护 RBS2000系列基站是爱立信公司的新一代产品,广泛用于我国的GSM900MHz移动通信网,也适用于GSM1800MHz通信系统。

与RBS200型基站相比,2000系列基站采用了模块化设计,集成度进一步提高,一个基站基本上是由DXU、ECU、PSU、TRU和CDU等几个替换单元(Replacem ent Unit,RU)组成。

如果基站出现硬件故障,直接更换相应的RU即可;同时RBS2000基站具有良好的人机接口,可很方便地通过OMT/OMT2软件实现笔记本和基站之间的通信,读取各种数据或进行相应的操作,所以维护起来很方便。

但在日常的维护工作中,有很多告警不易判断故障RU的位置或是否为硬件故障,这样问题就不好解决了。

下面就对在RSB2000的运行维护工作中常见的、有代表性的一些问题进行简单的总结,供大家参考。

1 电源单元故障及处理 -48V 型基站在工作时需要用到三至四块电源单位PSU(Power Supply Unit),PSU的作用是将-48V电压转换成+27V,供基站使用。

如果其中有一个PSU不工作,基站将产生一个电力供应不足的告警,并将告警送至BSC。

对于这类告警,应首先检查PSU的输入电压,因为有很多告警是因配电箱的熔丝熔断引起的,而并非PSU本身的故障。

如果PSU输入电压正常,我们就需要利用OMT或OMT2来判断故障的具体位置,因为从PSU面板的指示灯上是无法判断哪一个PS U有问题的。

利用OMT/OMT2来查看各PSU的状态或输出电流,如果某PSU的状态为Fault或无输出电流,则可判断该PSU坏,可将其更换后再观察。

RBS2000故障代码说明

RBS2000故障代码说明

status”- 在TG内所有现行故障:“System view /Select RBS 2000/Operations/Monitor/Fault 来自OMT- 对MO而言故障记录:RXELP:MO=RXO…; - 在MO内所有现行故障:RXMFP:MO=RXO…; - 在TG内所有现行故障(1级):RXMFP:MO=RXOTG-x,FAULTY,SUBORD; - 在MO内所有现行告警:RXASP:MO=RXO…;来自BSC注意2:有关IDB,RBS D B ,RU DB和内部配置(亦称本地配置)在http://www.eral.ericsson.se/~erafima/idb.html 网站上可以找到。

注意3:由于重新设置故障代码在http://www3-rmog-bts.ericsson.se/~erafima/startcause. 故障的位置,但是要记住有时是哪个单元检出故障,那个单元就指示,而不表明该单元就是故 注意:TRXC上的2A级故障可能表明1级故障存在次要的MO上。

一直读CF/TRXC上RU映射就会找到 2A 级:BSC/OSS发出告警A2或A3。

MO继续运行。

1B 级:除非故障停止或操作员介入,否则MO将永久退出运行。

BSC/OSS发出告警A2。

OSS 发出告警A2。

- 如果测试结果表明MO有故障,除非故障停止或者操作员介入,否则MO将永久退出运行。

BSC/ 障曲线,如果间断故障的数目太大,则MO将永久退出运行。

- 如果测试结果表明MO无故障,MO恢复运行并认为故障是间断出现的。

故障计数器保留间断故 1A级:MO退出运行,并测试。

根据接收到的BTS故障报告,BSC采取下列措施: 2A级:MO 内部,不影响MO功能的故障。

1B级:MO 外部,影响MO功能的故障。

1A级:MO 内部,影响MO功能的故障。

BTS 故障信息可以从具有MML(人-机对话)指令的BSC上或具有OMT的基站上重新得到。

RBS2000故障代码

RBS2000故障代码

RBS2000故障代码rbs2000系列(rbs2202、rbs2301、rbs2302、Rbs2206)故障代码1socf,externalconditionmapclass1故障代码:socfec1:4故障名称:l/rswi(btsinlocalmode)故障原因:dxu处于本地模式,BSC对其失去控制。

故障处理:按dxu上的local/remote按钮,使dxu进入remote远端模式。

故障代码:socfec1:5故障名称:l/rti(localtoremotewhilelinklost)故障原因:当dxu从本地状态切换到远程状态时,传输中断,导致告警产生。

故障排除:在保证正常传输的情况下复位dxu。

2socf,externalconditionmapclass2故障代码:socfec2:10故障名称:mailsfail(externalpowersourcefail)说明:适用r8a软件版本故障原因:PSU的直流或交流电源存在断路等问题。

故障处理:检查以下方面:基站交流是否停电- 48vpsu的直流输入开关是否跳闸?230V交流PSU的交流输入开关是否跳闸?Accu 故障或连接错误(仅适用于室外基站)故障代码:socfec2:11故障名称:alna/TMA故障描述:适用于R8a软件版本相关故障:aorxi1b:1―alna/tmafault故障原因:TMA塔顶放大器可能有故障。

使用TMA的接收信道较弱的接收信号,相当于减少了3.5db的灵敏度。

如果其它接收边也出现故障,会导致告警aorxi1b:1的产生。

tma的电流消耗可被cdu监测,可通过omt进行监控。

当tma的电流超出范围33-147ma,此告警产生。

tma的电流值门限可以通过omt在idb中设置。

故障处理:分别进行以下处理:检查馈线、跳线及接头是否正常?检查idb中tma相关参数的设置?更换tma注:如果TMA有两个放大器,如果其中一个发生故障,将产生电流值波动,cdu监测到这个情况,就会产生告警socfec2:12。

RBS2000故障代码表

RBS2000故障代码表

绪论:BTS的故障是按故障的起因和重要性进行分类的:▪ 1A级:MO内的故障,它会影响MO的功能特性.▪ 1B级:MO外的故障,它也会影响MO的功能特性.▪ 2A级:MO内的故障,它不会影响MO的功能特性.BSC要接收以上的BTS故障报告,应采用下列措施:▪ 1A级: MO退出操作和测试.- 如果测试结果表明MO没有故障,那么MO将返回操作状态,并且其故障以间歇性故障处理.故障计数器将对间歇性故障进行累加,当发生间歇性故障的次数太高时,MO将会永久地退出工作状态.- 如果测试结果表明MO有故障,那么MO将永久地退出工作状态,直到故障停止或人工干涉才能恢复正常状态. 在BSC/OSS上将会产生一个A2告警.▪ 1B级: MO将永久地退出工作状态,直到故障停止或人工干涉才能恢复正常状态. 在BSC/OSS上将会产生一个A2告警.▪ 2A级:在BSC/OSS上将会产生一个A2或A3告示警. 但MO仍处于工作状态.应注意的是:CF或TRXC上的2A级故障在从属MO中却被认为是1级故障.总是在CF/TRXC上读取RU的故障映象来进行故障定位.但有时应紧记要替换的被检测到的故障单元,以便更换. BTS的故障信息可以从BSC上或站上OMT接口用人机命令MML来获得。

▪从BSC上获得:- 在MO中所有激活的告警: RXASP:MO=RXO…;- 在TG中所有激活的故障(1级): RXMFP:MO=RXOTG-x,FAULTY,SUBORD;- 在MO中所有激活的故障: RXMFP:MO=RXO…;- MO的故障记录: RXELP:MO=RXO…;▪从OMT上获得:- 在TG中所有激活的故障: ”System view(系统视图) / 选择 RBS 2000 / Operations操作(或按右键) /Monitor(监视)/ Fault status(故障状态)”- 某个RU的故障记录: ”Hardware view(硬件视图) /选择RU / Operations操作(或按右键) / Save log(保存记录)” (只有 DXU, TRU和ECU才有记录区).如果在CF/TRXC上产生RU单元的故障映象,其上的红灯将会发亮. 但这不一定就指此单元一定有故障,这也可能指此单元检测到其他单元有故障。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Reference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGFault Code ListAbstractThis document lists the MO Fault Maps on the Abis interface.Application and target group•TRS system designers, who will partition the system into subsystems,allocate requirements to them and verify the requirements with productmanagement•TRS sub system designers, who will partition the subsystem into functionblocks, allocate requirements to them and verify the requirements withproduct management•system and subsystem testers, who will secure testability of therequirements and write test specifications according to the requirements•product management, who will evaluate the market demand for thesystem and present the system to potential customers•CME system designers, who will assure correctness of the TRS systemwithin the CME system.•Manual authors, who will describe i.e. maintenance and installation.Supplementary documentsNone.Reference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGContents1INTRODUCTION (3)1.1PURPOSE (3)1.2SCOPE (3)1.3REVISION HISTORY (3)1.4REFERENCES (4)1.5TERMINOLOGY (5)2GENERAL (8)3FAULT LISTS (9)3.1SO CF (9)3.2SO TRXC (14)3.3AO CON (19)3.4AO DP (20)3.5AO IS (20)3.6AO RX (21)3.7AO TF (23)3.8AO TS (25)3.9AO TX (26)4FAULT CODE INTERPRETATION (27)Approved CheckedRevReferenceDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG1 INTRODUCTION1.1 PURPOSEFault codes on the Abis interface are defined per MO.1.2 SCOPEThis document describes faults reported to BSC and possible HW causing thefault.This document is valid for RBS 2000.HISTORY1.3 REVISIONRev Date PurposeA 001013Document identical with 15/1551-HRB 105 01, Rev.VB 010213Approved after Twist KG and FR. CR46 included.D 010628Approved.E 010919 Updated with CR47A and 48A.F 020213Updated with CR50A, 52A-55A.G 020623Updated with CR 56B and 57A.H 021016Updated with CR 49C, 58A and 60A.J 030117Updated with CR64, RAM Soft error supervision inRC_System, CR65, Handling of HW Memory Error added.K 030203Updated with CR 59B, 62A-63A, 66A-67A.L 030328Updated with CR 69B, Fault split and removal of RBS 2205.M 030825Updated with CR72A: OMT interpretation of RBS2000 fault,CR73A: Add support for HCU/ASUN 030915Updated with CR74A: ASU cable fault instead of TMA faultS 040217Document converted to word. Updated with:CR75A New SE TRX_Y1LINK/XBUS_COLLISION,CR76A Timing Distribution Fault shall set SO TRXC I1B,CR77A XBus fault shall set SO TRXC I1B alarmT 040611Updated with: CR78A Remove LMU from documentation,CR364A Remove SO TRXC I2A:38Climate capacity reduced,CR412A Simplified solution for better QIM Fault handling…,CR358A Update Fault Code List for R11,CR515A ROMTIP:Add LMT in Fault Code List.Approved CheckedDateRevReference EAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGU 041116Updated with: CR 557B, Automatic Fault Recovery andCR499A, 4 Way Disversity.V 050412Updatedwith:CR623A: Jupiter - Improved Fault Filtering.CR645A: TG Synchronization Improvements, Phase 1CR666A: Introducing Feature BTS Automatic Restart aftervery long link breakCR868A: Add support for Feature 2204 to Fault Code ListCR928A: 2204: Implement TR35294 In Fault Code ListCR1015A: RBS 2250/HCHC SupportCR1060A: IR-UL Update Fault Code List with fault handlingfor malfunctioning IR-memory.CR1163A: Introduce new TX cable alarm.X 050616Updatedwith:CR1296: Jupiter, explanatory text for extension mapsY 050908Updated with CR1148 SE TRX_HW_MEMORY_ERRORshould be a class 1 alarmZ 051216Updated withCR2197 ‘RBS 2x16: Updates to Fault Code List’CR2209 ‘2x06 4WRD 12B: Fault Handling for new RX cables(Fault Code List).CR2318 ‘No PF_FAULT when removing TX-cable on CR..’CR2368 ‘add mu to SO CF RU map 0’AA AB AC 060929070215070509Updated with CR2843A: Extended RF Cable Supervision.Updated with CR3145B: RBS 2409: Fault Code List update.Updated with CR3242 , updates to Fault Code ListAD 071220Updated with CR3701 for DRUCR1AE 080229Included CR3932 Remove SO TRXC I2A:27 RX PATHFAULTAF 080609Updated with CR3950; Find Faulty Transmit Antenna Data -BTS PartAG 080825Updated with CR4045, Improved behaviour of Transcoderalarms1.4 REFERENCES/ABIS II/ Abis O&M Interface, Part II, Procedures208/155 19-HSC 103 12 UenReferenceRevDateApproved CheckedEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG/GD Fault Coordination/ General Description Fault Coordination20/1551-HRB 105 21 Uen/GD Fault Code Description/ General Description Fault Code Description47/1551-HRB 105 21 Uen1.5 TERMINOLOGY1.5.1 ConceptsFault NoThe fault number is equal to the bit position in the fault map reported over theAbis interface.Internal Fault Map Class 1A (I1A)Faults reported in this class are faults that do affect MO functionality. FaultyHW is part of the signaling MO.Internal Fault Map Class 1B (I1B)Faults reported in this class are faults that do affect MO functionality. Origin ofthe fault is external to the signaling MO.Internal Fault Map Class 2A (I2A)Faults reported in this class are faults that do not affect MO functionality.Faulty HW is part of the signaling MO.External Condition Map Class 1 (EC1)Conditions reported in this class are conditions that do affect MO functionality.The conditions are TG external.External Condition Map Class 2 (EC2)Conditions reported in this class are conditions that do not affect MOfunctionality. The conditions are TG external.Replacement Unit Map (RU map)Units reported in this map is HW suspected to be causing the faults in internalfault maps described above.MOManaged Object, the class of all object in the BTS O&M model which BSCcan communicate with.SOService Object, an abstract subclass of MO which handles hardware. A SOmanages one or more RUs.AOApplication object, an abstract subclass of MO which only handlesfunctionality.RUReplaceable Unit. Smallest unit in a RBS2000 cabinet which can be replaced.ReferenceRevDateApproved CheckedEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGLogical RUA unit which can be referred to but is not a single physical unit. There arethree different kinds of logical RUs:•Buses which often are referred to as a single physical unit but isimplemented in the backplane of the cabinet and/or with cables. When abus is pointed out in the RU-map it should be understood that faulty HWcan be any unit connected to the bus or the bus it self. Logical bus RUsare:- XBUS- LOCAL BUS- TIMING BUS- CDU BUS- IOM BUS- EPC BUS (previously POWER COMMUNICATION LOOP)- Y LINK- PSU DC CABLE•Antennas. With a logical antenna means the whole signal path betweenthe Transmitter/Receiver and the physical antenna. Logical RU is:- ANTENNALogical RUs in 1 and 2 above are pointed out when the analysis fails to give amore detailed localization of the fault. Still, the ambition is to not point out alogical RU.•Environment which collects circumstances that are not affectable fromthe base station. There are two groups under this RU: Power whichhandles external power and Climate which handles humidity andtemperature. Logical RU is:- ENVIRONMENTFor example if the temperature in the cabinet is to high or the incomingAC mains is out of range the logical RU ENVIRONMENT is pointed out asfaulty.RBS DBRBS data base also called IDB. The RBS data base is also regarded as areplaceable unit even if it is not tangible in a normal sense. It encompassesthe data contents of the data base not the medium it resides on.RAM Soft ErrorA RAM soft error is induced by an event that corrupts the data stored in thedevice. The device is not damaged. The device continues to operate normallyat once the corrupted data has been over written.Reference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG1.5.2 AbbreviationsACCU AC Connection UnitALNA Antenna Low Noise AmplifierASIC Application Specific Integrated CircuitBDM Battery and Distribution ModuleBFU Battery Fuse UnitBSU Base Station UnitCDU Combining and Distribution UnitCM Control ModuleCON LAPD ConcentratorCU Combining UnitCXU Configuration Switch UnitDB Data BaseDP Digital PathDSP Digital Signal ProcessordTRU double TRUDXU Distribution Switch UnitDU Distribution UnitECU Energy Control UnitEPC Environment and Power ControlESB External Synchronization BusFCU Fan Control UnitFU Filter UnitIDB Installation Data BaseIOM Internal O&MIS Interface SwitchIXU Interface and Switching UnitMCPA Multi-Carrier Power AmplifierPCM Pulse Code ModulationPCU Packet Control UnitPFWD Power ForwardPREFL Power ReflectedPSU Power Supply UnitPWU Power UnitRBS Radio Base StationRBS DB RBS DatabaseRF Radio FrequencyRRU Remote Radio UnitRU Replaceable UnitRX ReceiverRXU Receiver UnitTF Timing FunctionTG Transceiver GroupTIM Transmission Interface ModuleTMA Tower Mounted AmplifierTRA Transcoder Rate AdaptorTRS Transceiver systemTRU Transceiver UnitTRXC Transceiver ControllerTS Time SlotTU Timing UnitTX TransmitterApproved CheckedRevReferenceDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGTXU Transmitter UnitVCO Voltage Controlled OscillatorVSWR Voltage Standing Wave Ratio2 GENERALThe SO RU-map and I1A/I2A fault maps should be read together. The SOfault maps says what fault it is, and the RU-map says where the fault is.An AO I1B fault has a corresponding SO I2A fault. So by reading the I2A faultmap and the RU-map for SO CF or SO TRXC the HW causing the AO I1Bfault can be found. This is the case when BTS internal HW affects a singleAO. The AO is not allowed to report the HW it self since that is assigned tothe HW-responsible SO. One could say that the AO I1B fault map reports theconsequence and the SO I1A/I2A fault maps and the RU-map report thecause.Approved CheckedReferenceRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGLISTS3 FAULT3.1 SOCF3.1.1 SO CF, Internal Fault Map Class 1AFault No Fault type0 Reset, Automatic Recovery1 Reset, Power On2 Reset, Switch3 Reset, Watchdog4 Reset, SW Fault5 Reset, RAM Fault6 Reset, Internal Function Change7 XBus Fault8 Timing Unit VCO Fault9 Timing Bus Fault10 Indoor Temp Out of Safe Range1112 DC Voltage Out Of Range1314 Bus Fault15 IDB Corrupted16 RU Data Base Corrupted17 HW And IDB Inconsistent18 Internal Configuration Failed192021 HW Fault22 Air Time Counter Lost23 Time Distribution Fault..473.1.2 SO CF, Internal Fault Map Class 1BNot used.3.1.3 SO CF, Internal Fault Map Class 2AFault No Fault Type1 Reset, Power On2 Reset, Switch3 Reset, Watchdog4 Reset, SW Fault5 Reset, RAM Fault6 Reset, Internal Function ChangeReference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG7 RX Internal Amplifier Fault8 VSWR Limits Exceeded9 Power Limits Exceeded10 DXU-Opt EEPROM Checksum Fault1112 RX Maxgain/Mingain Violated13 Timing Unit VCO AgeingSupervision/CommunicationLost14 CDU15 VSWR/Output Power Supervision Lost16 Indoor Temp Out Of Normal Conditional Range17 Indoor Humidity18 DC Voltage Out Of Range19 Power and Climate System in Standalone Mode2021 Internal Power Capacity Reduced22 Battery Backup Capacity Reduced23 Climate Capacity Reduced24 HW Fault25 Loadfile Missing in DXU or ECU26 Climate Sensor Fault27 System Voltage Sensor Fault28 A/D Converter Fault29 Varistor Fault30 Bus Fault31 High Frequency of Software Fault32 Non-Volatile Memory Corrupted33 RX Diversity Lost34 Output Voltage Fault35 Optional Synchronization Source36 RU Data Base Corrupted37 Circuit Breaker Tripped or Fuse Blown38 Default Values Used39 RX Cable Disconnected40 Reset, DXU Link Lost41 Lost communication to TRU42 Lost communication to ECU43 Internal Configuration Failed44 ESB Distribution Failure45 High Temperature46 DB parameter fault47 Antenna Hopping Failure48 GPS Synch Fault49 Battery backup time shorter than expected50 RBS running on battery51 TMA Supervision/Communications Lost52 CXU Supervision/Communication Lost53 HW and IDB Inconsistent54 Timing Bus FaultFault55 XBus56 STN SYNCH57 RX Path ImbalanceReferenceRevDateApproved CheckedEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG..95Note: Fault No 48 to 95 are sent over Abis in the data element ‘Internal FaultMap Class 2A Extension’.3.1.4 SO CF, External Condition Map Class 1Fault No Fault Type12 LMT (BTS Locally Disconnected)34 L/R SWI (BTS In Local Mode)5 L/R TI (Local to Remote while Link Lost)67891011121314153.1.5 SO CF, External Condition Map Class 2Fault No Fault Type123456 O&M Link Disturbed789 RBS DOOR (RBS cabinet door open)10 MAINS FAIL (External power source fail)11 ALNA/TMA Fault12 ALNA/TMA Degraded13 Auxiliary Equipment Fault14 Battery Backup External Fuse Fault15Reference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG3.1.6 SO CF, Replacement Unit MapNo RU0 DXU, MU or IXU1 ECU2 MICRO RBS3 Y LINK4 TIM5 CDU6 CCU7 PSU8 BFU9 BDM10 ACCU11 ACTIVE COOLER12 ALNA/TMA A13 ALNA/TMA B14 BATTERY15 FAN16 HEATER17 HEAT EXCHANGER EXT FAN18 HEAT EXCHANGER INT FAN19 HUMIDITY SENSOR20 TMA CM21 TEMPERATURE SENSOR22 CDU HLOUT HLIN CABLE23 CDU RX IN CABLE24 CU25 DU26 FU27 FU CU PFWD CABLE28 FU CU PREFL CABLE29 CAB HLIN CABLE30 CDU BUS31 ENVIRONMENT32 LOCAL BUS33 EPC BUS / POWER COMMUNICATION LOOP34 IDB3536 TIMING BUS37 CDU CXU RXA CABLE38 CDU CXU RXB CABLE39 XBUS40 ANTENNA41 PSU DC CABLE42 CXU43 FLASH CARD4445 BATTERY TEMP SENSOR46 FCU47 TMA_CM CABLEReferenceRevDateApproved CheckedEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG48 GPS RECEIVER49 GPS RECEIVER DXU CABLE50 ACTIVE COOLER FAN51 BFU Fuse or Circuit Breaker52 CDU CDU PFWD CABLE53 CDU CDU PREFL CABLE54 IOM BUS55 ASU RXA UNITS OR CABLES56 ASU RXB UNITS OR CABLES57 ASU CDU RXA CABLE58 ASU CDU RXB CABLE59 MCPA60 BSU.95Note: No 48 to 95 are sent over Abis in the data element ‘Replacement UnitMap Extension’.Approved CheckedReferenceRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGTRXC3.2 SO3.2.1 SO TRXC, Internal Fault Map Class 1AFault No Fault Type0 Reset, Automatic Recovery1 Reset, Power On2 Reset, Switch3 Reset, Watchdog4 Reset, SW Fault5 Reset, RAM Fault6 Reset, Internal Function Change78 Timing Reception Fault9 Signal Processing Fault10 RX Communication Fault11 DSP CPU Communication Fault12 Terrestrial Traffic Channel Fault13 RF Loop Test Fault14 RU Data Base Corrupted15 XBus Communication Fault16 Initiation Fault17 X-Interface Fault18 DSP Fault19 Reset, DXU Link Lost20 HW And IDB Inconsistent21 Internal Configuration Failed22 Voltage Supply Fault23 Air Time Counter Lost24 High Temperature25 TX/RX Communication Fault26 Radio Control System Load27 Traffic Lost Downlink28 Traffic Lost Uplink29 Y Link Communication HW Fault30 DSP RAM Soft ErrorFault31 Memory32 UC/HC Switch Card missing or corrupt..473.2.2 SO TRXC, Internal Fault Map Class 1BFault No Fault Type0 CDU/Combiner Not Usable1 Indoor Temp Out Of Safe Range23 DC Voltage Out Of RangeReference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG4567 TX Address Conflict8 Y Link Communication Fault9 Y Link Communication Lost10 Timing Reception FaultFaultCommunication11 XBus..473.2.3 SO TRXC, Internal Fault Map Class 2AFault No Fault Type0 RX Cable Disconnected1 RX EEPROM Checksum Fault2 RX Config Table Checksum Fault3 RX Synthesizer Unlocked4 RX Internal Voltage Fault5 RX Communication Fault6 TX Communication Fault7 TX EEPROM Checksum Fault8 TX Config Table Checksum Fault9 TX Synthesizer Unlocked10 TX Internal Voltage Fault11 TX High Temperature12 TX Output Power Limits Exceeded13 TX Saturation14 Voltage Supply Fault15 VSWR/Output Power Supervision Lost16 Non-Volatile Memory Corrupted17 Loadfile Missing in TRU18 DSP Fault19 High Frequency of Software Fault20 RX Initiation Fault21 TX Initiation Fault22 CDU-Bus Communication Fault23 Default Values Used2425 TX Max Power Restricted26 DB parameter fault272829 Power Amplifier Fault30 CPU High Temperature3132 RX High Temperature33 Inter TRX Communication Fault3435 Traffic Burst InhibitApproved CheckedRevReferenceDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG36 RX Filter Loadfile Checksum Fault37 RX Internal Amplifier Fault3839 RF-loop Test Fault, Degraded RX40 Memory Fault41 IR Memory Not Started42 UC/HC Switch Card and IDB Inconsistent..473.2.4 SO TRXC, External Condition Map Class 1Fault No Fault Type1234 L/R SWI (TRU In Local Mode)5 L/R TI (Local to Remote while Link Lost)6789101112131415Reference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG3.2.5 SO TRXC, External Condition Map Class 2Fault No Fault Type..1516 TS0 TRA Lost (TS mode is IDLE)17 TS0 TRA Lost (TS mode is CS)18 TS0 PCU Lost (TS mode is PS)1920 TS1 TRA Lost (TS mode is IDLE)21 TS1 TRA Lost (TS mode is CS)22 TS1 PCU Lost (TS mode is PS)2324 TS2 TRA Lost (TS mode is IDLE)25 TS2 TRA Lost (TS mode is CS)26 TS2 PCU Lost (TS mode is PS)2728 TS3 TRA Lost (TS mode is IDLE)29 TS3 TRA Lost (TS mode is CS)30 TS3 PCU Lost (TS mode is PS)3132 TS4 TRA Lost (TS mode is IDLE)33 TS4 TRA Lost (TS mode is CS)34 TS4 PCU Lost (TS mode is PS)3536 TS5 TRA Lost (TS mode is IDLE)37 TS5 TRA Lost (TS mode is CS)38 TS5 PCU Lost (TS mode is PS)3940 TS6 TRA Lost (TS mode is IDLE)41 TS6 TRA Lost (TS mode is CS)42 TS6 PCU Lost (TS mode is PS)4344 TS7 TRA Lost (TS mode is IDLE)45 TS7 TRA Lost (TS mode is CS)46 TS7 PCU Lost (TS mode is PS)47Note: Fault No 16 to 47 are sent over Abis in the data element ‘ExternalCondition Class 2 Extension’.3.2.6 SO TRXC, Replacement Unit MapNo RU0 TRU, dTRU, DRU or RRU12 MICRO RBS3 CXU TRU RXA CABLEApproved CheckedRevReferenceDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG4 CXU TRU RXB CABLE5678910 CDU TO TRU PFWD CABLE11 CDU TO TRU PREFL CABLE12 CDU TO TRU RXA CABLE13 CDU TO TRU RXB CABLE14 CDU TO SPLITTER CABLE OR SPLITTER TO TRU RXACABLE15 CDU TO SPLITTER CABLE OR SPLITTER TO TRU RXBCABLE16 CDU TO TRU TX CABLE17 CDU TO SPLITTER CABLE OR SPLITTER TO CXU RXACABLE18 CDU TO SPLITTER CABLE OR SPLITTER TO CXU RXBCABLE19 SPLITTER TO DRU CABLE OR DRU TO SPLITTER RXACABLE20 SPLITTER TO DRU CABLE OR DRU TO SPLITTER RXBCABLE21 DRU TO DRU RXA CABLE22 DRU TO DRU RXB CABLE23 HCU TRU TX CABLE OR HCU OR CDU HCU TX CABLE24 BSU..47ReferenceRevDateApproved CheckedEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGCON3.3 AO3.3.1 AO CON, Internal Fault Map Class 1ANot used.3.3.2 AO CON, Internal Fault Map Class 1BNot used.3.3.3 AO CON, Internal Fault Map Class 2ANot used.3.3.4 AO CON, External Condition Map Class 1Fault No Fault Type12345678 LAPD Q CG (LAPD Queue Congestion)91011121314153.3.5 AO CON, External Condition Map Class 2Fault No Fault Type12345678 LAPD Q CG (LAPD Queue Congestion)91011ReferenceRevDateApproved CheckedEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG121314153.3.6 AO CON, Replacement Unit MapNot used. See Replacement Unit Map for SO CF for possible HW causing thefault.DP3.4 AOAO DP is not supervised.Note: The Digital Path is supervised by PCM Supervision.IS3.5 AOAO IS is not supervised.ReferenceRevDateApproved CheckedEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGRX3.6 AO3.6.1 AO RX, Internal Fault Map Class 1ANot used.3.6.2 AO RX, Internal Fault Map Class 1BFault No Fault type0 RX Internal Amplifier Fault1 ALNA/TMA Fault23 RX EEPROM Checksum Fault4 RX Config Table Checksum Fault5 RX Synthesizer A/B Unlocked6 RX Synthesizer C Unlocked7 RX Communication Fault8 RX Internal Voltage Fault9 RX Cable Disconnected10 RX Initiation Fault11 CDU Output Voltage Fault12 TMA CM Output Voltage Fault1314 CDU Supervision/Communication Fault15 RX High Temperature1617 TMA Supervision Fault18 TMA Power Distribution Fault19 RX Filter Loadfile Checksum Fault20 RX Cable Supervision Lost..47 RX Auxiliary Equipment Fault3.6.3 AO RX, Internal Fault Map Class 2AFault No Fault type0 CXU Supervision/Communication Fault1 RX Path Lost on A receiver side2 RX Path Lost on B receiver side3 RX Path Lost on C receiver side4 RX Path Lost on D receiver side5 RX Path A Imbalance6 RX Path B Imbalance7 RX Path C Imbalance8 RX Path D ImbalanceReference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG3.6.4 AO RX, External Condition Map Class 1Not used.3.6.5 AO RX, External Condition Map Class 2Not used.3.6.6 AO RX, Replacement Unit MapNot used. See Replacement Unit Map for SO CF and SO TRXC for possibleHW causing the fault.ReferenceRevDateApproved CheckedEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG3.7 AOTF3.7.1 AO TF, Internal Fault Map Class 1ANot used.3.7.2 AO TF, Internal Fault Map Class 1BFault No Fault Type0 Optional Synchronization Source1 DXU-Opt EEPROM Checksum Fault2 GPS Synch Fault..473.7.3 AO TF, Internal Fault Map Class 2AFault No Fault Type0 Frame Start Offset Fault..473.7.4 AO TF, External Condition Map Class 1Fault No Fault Type0 EXT SYNCH (No Usable External Reference)1 PCM SYNCH (No Usable PCM-Reference)23456 EXT CFG (Multiple Timing Masters)7 EXT MEAS (ESB Measurement Failure)89101112131415Reference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG3.7.5 AO TF, External Condition Map Class 2Fault No Fault Type0 EXT SYNCH (No Usable External Reference)1 PCM SYNCH (No Usable PCM-Reference)234567 EXT MEAS (ESB Measurement Failure)891011121314153.7.6 AO TF, Replacement Unit MapNot used. See Replacement Unit Map for SO CF for possible HW causing thefault.Approved CheckedRevReferenceDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGTS3.8 AO3.8.1 AO TS, Internal Fault Map Class 1ANot Used.3.8.2 AO TS, Internal Fault Map Class 1BNot used.3.8.3 AO TS, Internal Fault Map Class 2ANot used.3.8.4 AO TS, External Condition Map Class 1Fault No Fault Type123 TRA/PCU (Remote Transcoder/PCU Com. Lost)4567891011121314153.8.5 AO TS, External Condition Map Class 2Not used.3.8.6 AO TS, Replacement Unit MapNot used.Approved CheckedReferenceRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AGTX3.9 AO3.9.1 AO TX, Internal Fault Map Class 1AFault No Fault typeOffending0 TX..473.9.2 AO TX, Internal Fault Map Class 1BFault No Fault type0 CU/CDU Not Usable1 CDU/Combiner VSWR Limits Exceeded2 CDU Output Power Limits Exceeded34 TX Antenna VSWR Limits Exceeded56 TX EEPROM Checksum Fault7 TX Config Table Checksum Fault8 TX Synthesizer A/B Unlocked9 TX Synthesizer C Unlocked10 TX Communication Fault11 TX Internal Voltage Fault12 TX High Temperature13 TX Output Power Limits Exceeded14 TX Saturation151617 TX Initiation Fault18 CU/CDU HW Fault19 CU/CDU SW Load/Start Fault20 CU/CDU Input Power Fault21 CU/CDU Park Fault22 VSWR/Output Power Supervision Lost23 CU/CDU Reset, Power On24 CU Reset, Communication Fault25 CU/CDU Reset, Watchdog26 CU/CDU Fine Tuning Fault27 TX Max Power Restricted28 CDU High Temperature2930 TX CDU Power Control Fault31 Power Amplifier Fault32 TX Low Temperature33 CDU-Bus Communication Fault34 Y Link - XBus Collision Fault35 RX Path ImbalanceReference Approved CheckedRevDateEAB/FJG/RSJ (Katarina Isaksson) xrsstec2008-08-25 AG..47 TX Auxiliary Equipment Fault3.9.3 AO TX, Internal Fault Map Class 2AFault No Fault Type0 TX Diversity Fault1 Fast Antenna Hopping Failure..473.9.4 AO TX, External Condition Map Class 1Not used.3.9.5 AO TX, External Condition Map Class 2Not used.3.9.6 AO TX, Replacement Unit MapNot used. See Replacement Unit Map for SO CF and SO TRXC for possibleHW causing the fault.INTERPRETATIONCODE4 FAULTThe description of all fault codes is found in reference /GD Fault CodeDescription/.The descriptions are parsed into OMT and used by the function that displaysfault code descriptions.。

相关文档
最新文档