给排水设计计算书

给排水设计计算书
给排水设计计算书

给排水设计计算书

————————————————————————————————作者:————————————————————————————————日期:

?

高层建筑给排水课程设计计算书

建筑给排水课程设计说明书及计算书

目录 设计依据________________________________________________________ - 0 - 设计围__________________________________________________________ - 0 - 工程概况________________________________________________________ - 0 -

生活给水系统计算________________________________________________ - 1 - 1、高层给水计算_____________________________________________ - 1 - 1)各卫生间给水系统计算表_______________________________ - 2 - 2)顶层用户给水系统干管计算表___________________________ - 9 - 3)高层用户给水系统计算表______________________________ - 11 - 2、低层给水计算____________________________________________ - 13 - 3、水表选择________________________________________________ - 17 - 4、地下室加压水泵的选择____________________________________ - 18 - 生活污水排水系统计算___________________________________________ - 19 - 1、住宅卫生间排水计算______________________________________ - 19 - 2、厨房排水计算____________________________________________ - 23 - 3、商场公共卫生间排水计算__________________________________ - 26 - 4、排水附件的设置__________________________________________ - 28 - 5、检查井的设置____________________________________________ - 29 - 6、化粪池的设置____________________________________________ - 29 - 消火栓系统计算_________________________________________________ - 29 - 1、消火栓的布置___________________________________________ - 29 - 2、消防水量________________________________________________ - 31 - 3、水枪充实水柱高度的确定__________________________________ - 31 - 4、水枪喷嘴处所需压力计算__________________________________ - 32 - 5、水枪喷嘴出流量计算______________________________________ - 32 - 6、水带阻力计算____________________________________________ - 33 - 7、消火栓口所需压力计算____________________________________ - 33 - 8、消防系统管材选择________________________________________ - 33 - 9、水力计算________________________________________________ - 33 -

建筑给排水毕业设计任务书(DOC)

广东水利电力职业技术学院 2011届给水排水工程技术专业 毕业设计任务书与指导书 课题名称:广州某小学教学楼 给排水工程设计 专业班级 姓名 学号 指导教师:孙超 二O一三年十二月

第一部分 毕业设计任务书 一、毕业设计(论文)的内容与要求 1、毕业设计的内容 受广州某学校的委托,设计其教学楼,要求设计完善的建筑给水、排水和消防给水系统。并满足下列要求: 1)给水系统供水安全可靠,保证水质、水压、水量、水温; 2)排水畅通、气压稳定、室内环境卫生条件好; 3)技术先进、运行管理方便、投资少。 2、毕业设计的要求与数据 (1)工程概况 某小学教学楼建筑总面积为3010.8m2, 地上5层,各层高详见建筑图。各层功能详见平面所示,首层为架空层和水泵设备房、电房,2~5层为教室,每层设用男女卫生间,内设台式洗脸盆、大便器,小便槽等。教职工人数按学生人数的10%计。每层走廊预留恒温饮水机进水管(DN20,设置倒流防止器)。 (2)原始资料 A、建筑设计资料 1)各层建筑平面图 2)屋面、楼梯顶建筑平面图 B、给排水设计资料 3)据市政建设和环保部门批准文件决定,给水进水管从建筑北面的规划路给 水管DN150引入,市政给水管网常年提供可靠水压为0.25MPa,水质符合 饮用水标准。城市管网不允许直接抽水。 4)污水、雨水排出管可从建筑西南面的规划路排出,与城市排水管网相连。 该市设有城市污水处理厂,室内生活污水需经化粪池处理后排入城市污水 管道。接入市政雨污水管前必须设置水质检测井。

(3)工程地质和地震资料 不考虑地震影响。 二、毕业设计(论文)应完成的工作 1、设计、计算、说明书一份,(约为2万字),装订成册。包括6部分: 1)设计总说明; 2)目录 3)前言:设计资料、工程性质、设计任务和设计范围、设计内容等; 正文: 1、分析设计资料,确定建筑内部的给排水、消防系统方式。 2、用水房间卫生器具及管道的布置及敷设。 3、室内外管道材料、设备的选用及敷设安装方法的确定。 4、建筑内部给排水系统、消防系统的计算。 5、水泵房布置及计算。 4)结论 5)参考文献 6)致谢 2、设计图纸包括: 1)图纸目录; 2)总说明、图例、设备统计表; 3)各层给排水平面图(首层给、排水平面图分开) 4)各层水消防平面图 5)消防水箱大样图; 6)泵房平面布置图; 7)泵房剖面及管道轴测图; 8)给水管道系统图;

给排水毕业设计建筑给排水开题报告

本科生毕业设计(论文)开题报告题目:综合楼给水排水设计 学院:建筑工程学院系土木工程 专业: 班级: 学号: 姓名: 指导教师: 填表日期:

一、选题的依据及意义 本设计选题依据:学校对给排水专业学生的培养方案而定,作为即将毕业的我们,应该对自己的专业有更深刻的了解,也应该更多的去学习如何将所学知识运用到实践中去。因此,本设计选择课题为高层综合楼给排水设计。 一般来讲,任何建筑都必须进行给排水设计,这与建筑使用的安全性和舒适性密切相关。随着土地资源的紧张,高层建筑越来越多,高层建筑给排水设计成为设计师的必备技能。 该设计建筑共有18层,是以公共餐厅、办公及高档旅馆为主题的综合楼,几乎涉及了建筑给排水设计的所有内容。我希望此次设计达到以下几点目标: (1)通过毕业设计,巩固自己所学的基础理论和专业知识,加强自己的基本技能,使自己的知识体系综合起来,以达到学以致用,独立完成建筑给排水设计的目的。 (2)通过毕业设计,掌握资料获取、处理数据和计算机应用等方面的能力,培养自己的实践能力、创新能力和独立思考意识。 (3)通过毕业设计,了解社会生产实际中的问题,及时发现自己知识的缺陷和漏洞,补充自己没有掌握的知识,为以后的工作打好坚实的基础。 二、国内外研究现状及发展趋势(含文献综述) 随着建筑业的发展,建筑给水排水专业迅速发展,已成为给水排水中不可缺少而又独具特色的组成部分。我国建筑给排水积累了实践经验,借鉴了国外的新技术,专业技术有了明显的突破和发展, 其中消防给水系统在建筑给排水中的发展尤为突出。此外,我国建筑给排水产品设备的发展也促进了建筑给排水技术的发展。建筑给水排水技术的发展是与科研工作、工程实践(设计、安装)、产品开发等多方面有关。近年来, 高层建筑给排水日趋增加, 例如上海在浦东建成的金茂大厦和上海国际环球金融中心。在产品开发上, 也不断引进先进国家的技术。为了使传统的给排水工程与社会可持续发展在我国的经济条件下有机结合, 我国正积极发展水工业,作为给水排水工程在21世纪的新发展。 国内外对建筑给排水的研究目前主要集中在两个方向,分别是节水新技术和节能新技术。 1、节水新技术 (1)推广使用优质管材、阀门 由于传统镀锌钢管容易生锈,会造成水质污染,且长时间闲置后再使用时会有锈水放出导致浪费,同时接头处如果锈蚀也会漏水渗水。采用新型管材如铝塑复合管、钢塑复合管、不锈钢管、铜管、PP—R管、PE管、PVC—U管等能很好的解决此类问题。 阀门是建筑给排水中最常用的配件之一,其类型和质量的好坏也能影响用水的质量。一

建筑给排水消防设计计算书

青岛天迅电气有限公司二期厂房 建筑给水排水设计计算书 (一) 计算依据: 根据中华人民共和国现行的《建筑给水排水设计规范》(GB50015-2003)、《建筑设计防火设计规范》(GB 50016-2006)等规范规定。 (二) 计算内容: (1)给水系统: 1. 办公楼卫生间及食堂厨房的给水计算。 2. 办公楼卫生间及食堂厨房的排水计算。 3.室外化粪池、隔油池的计算与选型。 4.消防给水系统的计算。 (三) 计算过程: 1. 办公楼卫生间及餐厅食堂的给水计算 根据规范办公楼给水设计秒流量公式为: q g =0.2αNg 式中q g ——计算管段的给水设计秒流量; Ng ——计算管段的卫生器具给水当量总数; α—— 根据建筑物用途而定的系数 办公楼取1.5 餐厅的厨房给水管道设计秒流量为: q g =b N q 00∑ 式中q g ——计算管段的给水设计秒流量; q 0——同类型的一个卫生器具给水额定流量; N 0——同类型卫生器具; b ——卫生器具的同时给水百分数; 2. 办公楼卫生间及食堂厨房的排水计算 根据规范办公楼生活排水管道设计秒流量公式为: max 12.0q N q P p +=α 式中p q ——计算管段排水设计秒流量; P N ——计算管段的卫生器具排水当量总数; α——根据建筑用途而定的系数 取2.0 max q ——管段上最大一个卫生器具的排水流量

餐厅的厨房排水管道设计秒流量为: q g =b N q 00∑ 式中q g ——计算管段的排水设计秒流量; q 0——同类型的一个卫生器具排水流量; N 0——同类型卫生器具; b ——卫生器具的同时排水百分数; 3.室外化粪池、隔油池的计算与选型 化粪池计算公式: 污水部分容积:1000241?= Nqt V 污泥部分容积:1000)00.1(2 .1)00.1(2?-?-=c K b NT V α 化粪池总有效容积:V = V1 + V2 已知条件: N :化粪池实际使用人数:25人 q :生活污水量:25升/人·天 t :化粪池污水停留时间:12小时 α:每人每天污泥量:0.4升/人·天 T :污 泥 清 掏 周 期:180天 b :进化粪池新鲜污泥含水率:95% c :发酵浓缩后污泥含水率:90% K :污泥发酵后体积缩减系数:0.8 计算过程: 313.01000241225251=???= V ()()1000 90.000.12.18.095.000.11801507.02?-??-???=V 512.1= 立方米824.1512.1313.0=+=V 选用2号化粪池详见图集L03S002-114 隔油池参照图集L03S002-12设计参数确定型号为乙型隔油池

建筑给排水毕业实习设计报告工地实习日记(超多篇看下载慢慢看)

6月19日星期三天气晴 昨晚回宿舍后学习图纸,一直看到11点多钟,上床后满脑子尽是图纸在打架。这是一个技改扩建项目,主要内容为建设一个工厂自备热电站和碱回收工程,大小单位工程36个,主厂房将锅炉房、常用配电室、汽轮机房合为一体,并与煤廊、烟囱连接,结构复杂,难度高,是整个工程项目的核心部分。建设项目中,也有结构极为简单的平房,如砖砌体结构的仪器维修车间和钢结构的干煤棚。还有多个地下钢筋混凝土水池和两个45m ( 高的烟囱)一个是钢筋混凝土的,另一个是砖烟囱*。赵工程师说,这个工程要力争中标。我想中标后参加该工程施工,对我是一个极好的学习和锻炼的机会。想着想着,我成了一个头戴安全帽、身穿工作服、站在高高的脚手架上、进行质量检查的实习施工员,我心旷神怡地向着远方眺望,突然吹来一阵大风,脚手架摇晃了几下后把我抛到了空中,我大叫了一声醒了,原来是一个梦,只觉得背上全是冷汗。 6 月21 日星期五天气阴 上午和赵工程师去造纸厂工地进行实地考察。赵工程师说,在编制施工组织设计(方案)前,一定要到现场进行实地考察,千万不能想当然地闭门造车。只有详细了解了现场的具体情况后,编制的施工组织设计(方案)才有针对性,也才有较好的实用价值。临行前,赵工程师要我了解以下一些主要内容: 1.现场供电情况(线路、容量等);

2. 现场供水、排水情况(线路、容量等); 3. 现场道路畅通情况; 4.现场可供利用的建筑物情况; 5. 现场已有地下管线情况; 6.现场周围城市测量控制点情况等。 赵工程师说,如果是外地工地,还应了解当地施工期间的气温、降雨量、风力、风向以及地震烈度、地方资源、地方交通运输、地方施工协作单位以及当地建设行政主管部门的有关建筑市场的管理文件等。 下午,赵工程师主持召开技术工作会议,讨论造纸厂投标工程施工组织设计编制要点,要求项目部有关人员提出意见和建议。大家从进度、质量、安全、成本等多方面提出了各自的意见,我听了很受启发。我最后一个发言,根据设计图纸和上午了解的现场情况,提出了三个方面的建议。 第一,建议本工程以主厂房为主线编制施工进度网络图。为便于锅炉房和汽轮机房的屋架制作和屋面吊装工作,建议两车间中的楼层部分在屋面吊装结束后再施工,这样可大大加快主厂房的施工进度。第二,现场可供利用的原有建筑物不多,如果全部搭建临时用房,成本较高。建议将两栋结构简单的平房———砖混结构的仪器维修车间和钢结构的干煤棚开工时抢建后(干煤棚的钢柱、钢屋架提前在综合厂预制好),作为工地办公用房、工具用房和工地搅拌站用房,以节约搭设临时设施的费用。

给排水计算书

Xxxxxxxxxxxxxx学校 电气xxxx班 姓名:xx 指导教师;xx 学号:xxxxxxxxx 2011-5-10

一、工程概况: 该大楼是一栋办公大楼,该建筑地下一层,地上十一层,高度为35米,地下室为设备用房,包括水泵、水池、空调机房、报警阀用房、汽车库、高低压配电室、变电室。底层至十一层为办公室。 给水水源:本建筑物以城市给水管网作水源,建筑物北向有城市给水,管径DN500mm ,市政可提供水源280Kpa 。 排水条件: (1)城市排水管网为雨污分流排水系统。 (2)室外排水管网位于建筑物北向,排水管管径为ф500mm, 相对标高为了-2.0米, 雨水管径为ф1000mm,相对标高为-2.5米。 二、设计范围 设计给排水平面图:建筑给水管道布置、建筑排水管道布置、室内消火栓布置、自动喷水系统布置、 设计给排水系统图:给水系统、排水系统、消火栓系统、自动喷水系统、大样图:卫生间大样图、泵房大样图、集水池大样图室外给排水平面图:室外给排水管道布置、室外给排水管道附件、检查井、阀门井 三、设计依据: 1、《建筑给水排水设计规范》GB 50015-2003; 2、《全国民用建筑工程设计技术措施?给水排水》; 3、《高层民用建筑设计防火规范》GB 50045-95 (2001年版); 4、《自动喷水灭火系统设计规范》GBJ 50084-2001; 5、《建筑灭火器配置设计规范》GBJ 140-90 (1997年版); 6、上海市消防局沪消发[2002]37号《关于规范建筑灭火器配置的

通知》; 7、《民用建筑水灭火系统设计规范》DGJ08-94-2001; 8、其它现行的有关设计规范、规程和规定; 9、有关主管部门对方案设计的审查意见; 10、业主提出的设计要求; 11、建筑工种提供的图纸;

给排水设计计算书

给排水设计计算书

万科红三期给排水设计计算书 一、生活给水 (一)用水量计算 1、保障房140户,2人/户,250L/人·日计,则最高日生活用水量=2X250X140/1000=70(m3/d); 2、住宅720户,3.5人/户,250L/人·日计,则最高日生活用水量 =3.5X250X720/1000=630(m3/d); 3、公寓324户,4人/户,300L/人·日计,则最高日生活用水量 =4X300X324/1000=388.8(m3/d); 4、办公楼建筑面积为29938.4m2,有效面积按60%建筑面积计,人均有效面积为6m2,则实际使 用人数约为3000人,50L/人·班计,则最高日生活用水量=50X3000/1000=150(m3/d); 5、商业建筑面积为19947.27m2,有效面积按80%建筑面积计,每m2营业厅面积6L/日,则最高 日生活用水量=19947.27X0.8X6/1000=95.7(m3/d)。 本工程分2个生活水池:生活水池和商业水池各一座,其中生活水池供保障房、住宅及幼儿园使用,公寓、办公楼和商业用水由商业水池供给。 生活水池容积:(70+630 )x20%=140m3 商业水池容积:(388.8+150+95.7)x20%=126.9m3,取130m3 (二)分区计算 地块周边市政管网水压极低,除地下车库冲洗水采用直供水外,所有楼层考虑加压供水。 住宅生活给水系统分高、低两个区:

低区: 4、5栋 3~14层, 6~8栋 2~14层,保障房3~14层 高区: 4~6栋 15~32层, 7、8栋 15~31层 商业给水系统分高、中、低两个区: 低区:-1~2层 中区:公寓:3~16层,办公楼3~11层(其中3层无卫生间) 高区:公寓:17~30层,办公楼12~22层 (Ⅰ)住宅低区: a)住宅: Ng4低= Ng5低=(4.75X4+4)X12=276 , Ng7低= Ng8低=(4.75X4+4)X13=299 Ng6低=(4.75+6)X2X13=279.5 b)保障房: Ng10低=4X10X12=480 查表得q4低≈4.4L/s ,q5低≈4.4L/s ,q6低≈4.4L/s ,q7低≈4.6L/s ,q8低≈4.6L/s ,管径为DN80 ;q10低≈6.52L/s ,管径为DN100 ; Ng总低=1909.5,查表得q总低=17.10L/s ,管径为DN150 ; 又∵H 低区=5+48.1+15+15=83.1m,实际值按计算值的1.05倍计,得H 低区 ≈87.3m ∴主泵DL65-16x6,工作时Q=9.0L/s,H=86m,N=15KW,3台,2用1备 辅泵DL50-15x6,工作时Q=3.8L/s,H=86m,N=5.5KW,1台 (Ⅱ)住宅高区: Ng4高= Ng5高=(4.75X4+4)X18=414 , Ng7高= Ng8高=(4.75X4+4)X17=391 Ng6低=(4.75+6)X2X17=365.5 查表得q4高≈5.6L/s ,q5高≈5.6L/s ,q6高≈5.2L/s ,q7高≈5.5L/s ,

2013-建筑给排水毕业设计

毕业设计 [论文] 题目:重庆市快捷大酒店 学院:市政与环境工程学院 专业:给水排水科学与工程 姓名:宋严 学号:024409135 指导老师:朱伟萍 完成时间:2013年6月

摘要 本设计为重庆市快捷大酒店,是一幢16层的大酒店的设计,设计内容主要包括给水冷水系统、排水系统、消防系统、热水系统这四大块的设计。 室内冷水系统分为低区与高区两个区供水,低区为地下室至四层,由市政管网直接供水;高区为五层至十六层,根据要求,在地下室设生活水池,然后由变频泵抽水为高区供水。室内排水系统采用合流制,每个卫生间设置独立的排水立管,地下室至四层共有9根立管,五层至十六层为标准套房,卫生间布局一样,每层有34个房间,故共需34根立管,并且由于到四层时,这些立管位于办公室、商场等的房间中部,所以需另设立管,总计59根。消火栓系统不分区,在地下室设置消防水池,楼顶设置高位水箱。按照相关规定每层都需设置闭式自动喷淋系统,共分为五个区,水源来自于地下室的消防水池。另外,根据实际情况,综合考量之后,本酒店五层到十六层还需设置热水系统,热水供应方式采用集中供热,热媒采用蒸汽,采用半循环里面的干管循环系统。 关键词:大酒店,高层,给水系统,排水系统,消火栓系统,闭式自动喷淋系统,热水系统

Abstract The design for the Chongqing express Le Grand Large Hotel, is to design a 16 - storey Le Grand Large Hotel, design content mainly includes these four large water supply water system, drainage system, fire control system, hot water system. Indoor water supply system is divided into low and high two district water supply, low area as the basement to the four layer, by the municipal water supply pipe network directly; the area of five to sixteen layers, according to the requirements of life, a pool in the basement, and then pumped by frequency conversion pump for high water. Indoor drainage system adopt confluence, each toilet set independently of the drainage tube, the basement to the four layer consists of 9 vertical pipes, five layer to the sixteen layer as a standard suite, room layout, each floor has 34 rooms, so a total of 34 riser, and because of the four layer, the middle the room is located in the vertical pipe office, shopping malls, so need to set up a total of 56 root canal. Fire hydrant system does not partition, setting fire pool in the basement, roof water tank. In accordance with the relevant provisions of each layer shall be installed closed automatic sprinkler system, is divided into five zones, water from the basement of pool fire. In addition, according to the actual situation, comprehensive consideration, this hotel five layer to the sixteen layer also need to set the hot water system, water supply mode with centralized heating, heat medium with steam, with half cycle inside the stem vascular system. Keywords: Le Grand Large Hotel, top, water supply system, drainage system, fire hydrant system, closed automatic sprinkler system, hot water system

建筑给排水毕业设计计算书

目录 第一章室内冷水系统 (3) 一竖向分区 (3) 二用水量标准及计算 (3) 三冷水管网计算 (4) 四引入管及水表选择 (9) 五屋顶水箱容积计算 (10) 六地下贮水池容积计算 (11) 七生活水泵的选择 (11) 第二章室内热水系统 (12) 一热水量及耗热量计算 (12) 二热水配水管网计算 (12) 三热水循环管网计算 (15) 四循环水泵的选择 (16) 五加热设备选型及热水箱计算 (17) 第三章建筑消火栓给水系统设计 (18) 一消火栓系统的设计计算 (18) 二消防水泵的选择 (20) 三消防水箱设置高度确定及校核 (20) 四消火栓减压 (20) 五消防立管与环管计算 (21) 六室外消火栓与水泵接合器的选定 (21)

第四章自动喷水灭火系统设计 (22) 一自动喷水灭火系统的基本设计数据 (22) 二喷头的布置与选用 (22) 三水力计算 (22) 四水力计算 (23) 五自动喷水灭火系统消防泵的选择 (26) 第五章建筑灭火器配置设计 (28) 第六章建筑排水系统设计 (29) 一排水管道设计秒流量 (29) 二排水管网水力计算 (29) 三化粪池设计计算 (33) 四户外排水管设计计算 (34) 第七章建筑雨水系统设计 (35) 一雨水量计算 (35) 二水力计算 (36)

第一章室内冷水系统 一.竖向分区 本工程是一栋十二层高的综合建筑,给水分两个区供给。一、二、三层商场和办公室作为低区,由市政管网直接供水;三至十二层客房作为高区,由屋顶水箱供水。 二.用水量标准及用水量计算 1.确定生活用水定额q d 及小时变化系数k h。 根据原始资料中建筑物性质及卫生设备完善程度,按《建筑给水排水规范》确定用水定额和小时变化系数见下,未预见用水量高区按以上各项之和的15%计,低区按10%计。列于用水量表中。 2.用水量公式: ①最高日用水量 Q d =Σmq d /1000 式中 Qd:最高日用水量,L/d; m:用水单位数,人或床位数; q d :最高日生活用水定额,L/人.d,L/床.d,或L/人.班。 ②最大小时生活用水量 Q h =Q d K h /T 式中 Q h :最大小时用水量,L/h; Q d :最高日用水量,L/d; T: 24h; K h :小时变化系数,按《规范》确定。⑴.高区用水量计算 客房:用水单位数:324床; 用水定额:400L/(床/d); 时变化系数Kh=2; 供水时间为24h 最高日用水量Qd=324×400=129600L/d 最高日最大时用水量Qh=Kh×Qd/24=10.8 m3/h 未预见水量:按15%计,时变化系数Kh=1. 最高日用水量Qd=129600×15%=19400L/d 最高日最大时用水量Qh=19400/24=0.81 m3/h ⑵.低区用水量计算 办公:用水单位数:442×2×60%/7=76人 用水定额50L/(人*班) 时变化系数Kh=1.5

给水排水工程毕业设计开题报告

给水排水工程毕业设计开题报告 随着我国经济的快速发展和人们生活水平的日益提高,人们的消费能力和消费水平有了极大的提升,商务、度假、旅游等活动使我国城市酒店业得到了快速的发展。现代星级酒店作为一个城市的名片和对外窗口,其酒店形象和服务水平都从侧面反映出这个城市的整体形象和文化特质。因此,现代星级酒店建筑设计不仅要注重建筑外形的气质塑造,还应致力于其良好的内在功能品质及酒店文化性与异质性的挖掘。作为建筑给水排水设计人员,在设计过程中除了按国家有关规范进行统筹考虑、全面规划外,还要强调供水安全可靠性的同时,尽可能地采取节能意义的措施和设计,以免造成不必要的水电浪费。结合当前水资源缺乏的严峻形势,立足建筑给排水,提出一些建议,以减少水资源的隐形浪费,实现节约用水。还必须考虑到给排水系统的噪声控制,结合新工艺和自身的工作经验在舒适性和经济性间寻求平衡点将室内给排水噪声减到最低,树立整体环境意识,努力为人们营造一个安静和舒适的室内环境。同时,酒店的功能复杂,失火可能性大,失火后蔓延迅速,人员疏散及扑救困难。为此,必须设置安全可靠的室内消防给水系统,满足各类消防的要求,而且也是酒店质量审核中的重中之重。因此,酒店室内给排水、消防给水工程在设计方面,都比一般室内给排水工程、消防给水提出了更高的要求。

通过该毕业设计,提高资料检索、文献阅读、设计计算、绘制图纸、编写设计说明的能力;培养自己理论联系实际的独立工作能力,综合分析、判断的思维能力,运用所学知识解决实际问题的能力等。同时达到对学习成果的综合性总结和检阅,也是以后从事相关工作的最初尝试。 随着人们生活水平的提高和居住环境的改善,人们对室内噪声越来越重视。据调查,在发达国家,人们在室内滞留的时间已占全天的90%,因此对室内噪声环境的要求越来越高。然而,由于建筑施工、安装和给排水管道的安装及卫生设备的选型不当,加上水泵自身的机械振动等诸多因素,室内的噪声环境愈加严重。在现实生活中,由于噪声过大而干扰人们的 正常生活,影响人们的身体健康的事件屡见不鲜。很多住宅室内的实际噪声都超过40dBA,在这样的噪声环境中生活不但会严重影响人们的休息质量,干扰脑力劳动者的工作,使人们产生失眠、疲劳、头晕、记忆力减退等症状,长此下去还会导致人们产生神经衰弱症。不仅如此,因噪声扰民而使业主与开发商对簿公堂的民事诉讼案也不在少数。据报道,北京市某小区业主李某因楼下的生活给水泵房噪声过大而严重扰乱其作息秩序,起诉开发商,法院一审判令开发商采取控制噪声的措施,并赔偿李某精神损失费十万元,创下全国噪声扰民赔偿记录。

住宅给排水计算书

XXXXX六期F37-2型住宅工程计算书 专业分类给排水 姓名 2008年7月30日

一、工程概况: 本工程位于XXXXX ,为低层住宅,耐火等级为二级,建筑面积xxx m 2,建筑占地面积 xxx m 2,地下1层,地上8层,建筑总高 25.10m 。 管材:给水管为钢衬塑复合管,排水管为PVC-U 排水塑料管。 二、市政条件: 给水:由市政给水管网供水。 高区:市政管径为 DN150,入口水压约 0.59MPa 。 低区:市政管径为 DN100,入口水压约 0.29MPa 。 消防:由市政消防管网供水,管径为 DN200,入口水压约 0.61MPa 。 三、给水管道水力计算: 取最不利的管段进行计算,即取户型二(A )的JL1-4、JL2-4计算。 a. 给水用水定额与时变化系数 依据《建筑给水排水设计规范》(GB 50015-2003),户型二(A )有两卫一厨,取4人/户,最高日生活用水定额q=320L/(人?d),时变化系数Kh=2.5。 b. 最高日用水量 Qd=mq d =4×320=1280L/d=1.75 m 3/d Q d —— 最高日用水量,单位(升/天); m —— 用水总人数,单位(人); q d —— 人均生活用水定额,单位(升/人天)。 c. 最高日最大时用水量 q hmax =Q d ×K h /T =1.28×2.5/24=0.133 m 3/h q hmax —— 最大时生活用水量,单位(m 3/h ); Q d —— 最高日用水量,单位(m 3); K h —— 小时变化系数; T —— 用水时间,单位(h )。 d. 给水管网水力计算 1)设计秒流量计算 按公式q g =0.2×U ×N g A 、最大用水时卫生器具给水当量平均出流概率: 00100% 0.23600 h g q m k U N T ??= ???? U o ——生活给水管道的最大用水时卫生器具给水当量平均出流概率(%); q 0——最高用水日的用水定额; m ——每户用水人数; k h ——小时变化系数; N g ——每户设置的卫生器具给水当量数; T ——用水时数(h); 0.2—— 一个卫生器具给水当量的额定流量(L/s)。 N g =8.00(洗涤盆1个1.00,洗脸盆2个0.75,大便器2个0.50,淋浴器2个0.75,拖布盆1个1.00,家用洗衣机1个1.00,室外绿化龙头1个1.00(仅一层有),绿化龙头1个1.00。) U 0=320×4×2.5/0.2/8/24/3600×100%=2.31% 取U 0=2.5%

高层建筑给水排水管道布置规范标准(毕设).docx

-*给水排水管道敷设规范及要求(整理的很全面) 1给水管道的敷设及管材 室内给水管道的敷设、布置应严格按照建筑给排水设计规范 (G B-50015-2003 )的要求进行,建筑室内管道布置和敷设原则 如下: (1)室内生活给水管道宜布置成枝状管网,单向供水。 (2)室内给水管道不应穿越变配电房、电梯机房、通信机房、 大中型计算机房、计算机网络中心、音像库房等遇水会损坏设备和 引发事故的房间,并应避免在生产设备上方通过。室内给水管道的 布置,不得妨碍生产操作、交通运输和建筑物的使用。 (3)室内给水管道不得布置在遇水会引起燃烧、爆炸的原料、 产品和设备的上面。 (4)埋地敷设的给水管应避免布置在可能受重物压坏处。管道 不得穿越生产设备基础,在特殊情况下必须穿越时,应采取有效的 保护措施。 (5)给水管道不得敷设在烟道、风道、电梯井内、排水沟内。 给水管道不宜穿越橱窗、壁柜、给水管道不得穿过大便槽和小便槽, 且立管离大、小便槽端部不得小于 0.5m 。 (6)给水管道不宜穿越伸缩缝、沉降缝、变形缝。如必须穿越 时,应设置补偿管道伸缩和剪切变形的装置。 (7)塑料给水管道在室内宜暗设。明设时立管应布置在不易受 撞击处,如不能避免时,应在管外加保护措施。塑料给水管道不得 与水加热器或热水炉直接连接,应有不小于0.4m 的金属管段过渡。

(8)室内给水管道上的各种阀门,宜装设在便于检修和便于操 作的位置。 (9)建筑物内埋地敷设的生活给水管与排水管之间的最小净距,平行埋设时不应小于 0.5m ;交叉埋设时不应小于 0.15m ,且给水管道应在排水管的上面。 (10)给水管的伸缩补偿装置,应按直线长度、管材的线膨胀 系数、环境温度和管内水温的变化、管道节点的允许位移量等因素 经计算确定。应尽量利用管道自身的折角补偿温度变形。 (11)当给水管道结露会影响环境,引起装饰、物品等受损害时,给水管道应作防结露保冷层,防结露保冷层的计算和构造,按 现行的《设备及管道保冷技术通则》执行。 (12)给水管道暗设时,应符合下列要求: ○1不得直接敷设在建筑物结构层内; ○2干管和立管应敷设在吊顶、管井、管窿内,支管宜敷设在楼(地)面的找平层内或沿墙敷设在管槽内; ○3敷设在找平层或管槽内的给水支管的外径不宜大于25mm ; ○4敷设在找平层或管槽内的给水管管材宜采用塑料、金属与塑 料复合管材或耐腐蚀的金属管材; ○5敷设在找平层或管槽内的管材,如采用卡套式或卡环式接口 连接的管材,宜采用分水器向各卫生器具配水,中途不得有连接配件,两端接口应明露。地面宜有管道位置的临时标识。 (13)给水管道应避免穿越人防地下室,必须穿越时应按人防 工程要求设置防暴阀门。

2014届给排水专业毕业设计论文(全)

摘要 本设计是关于贵州省六盘水市给水排水工程的管网设计,它包括给水排水系统、污水排水系统和雨水排水系统。设计的主要内容和深度应按照基本建设程序及有关的设计规定、规程确定。通常,给水管道系统的主要设计内容包括:设计基础数据(包括设计地区的面积、设计人口数、用水定额)的确定;给水管道系统的平面布置;给水管道系统设计流量计算和水力计算。污水系统采用完全分流制排水系统。污水排水系统的管网设计内容包括划分排水面积,布置管道系统;根据设计人口数和污水定额,计算污水设计流量;根据污水水力计算表进行污水管道的水力计算,确定管径、坡度、流速及埋设深度等设计参数;绘制污水管道平面图和纵剖面图。雨水排水系统的管网设计内容包括划分排水面积,进行雨水管渠定线,确定出水口的位置;划分设计管段,计算各管段设计流量;根据雨水水力计算表进行雨水管渠水力计算,确定管径、坡度、流速及埋设深度等设计参数;绘制雨水管道平面图和纵剖面图。 关键词:排水系统,管道布置,设计参数,水力计算

ABSTRACT The design is on the LiuPanShui in Guizhou Province, drainage pipe network engineering design includes a water supply and drainage system, a sewage drainage system and a stormwater drainage system.Design of the main contents and depth should be in accordance with the basic constructive procedures and relevant designed rules and procedures. Usually, the main designed content of water supply pipeline system includes: basic designed data (including the area of the design area, designed population and water quota) determination; The layout of Water supply pipeline system; Design flow calculation and hydraulic calculation of Water supply piping system. Sewage system is completely separate and drainage system. The pipe network design content of the sewage drainage system includs the division of the drainage area, layout of piping systems; population and sewage fixed according to the design, calculation of sewage design flow; hydraulic calculation of the sewers, the sewage hydraulic computation to determine the diameter, slope, flow rate and buried depth of the design parameters; draw the sewage pipeline plan and profile maps. Stormwater drainage system pipe network designing content includs division of the drainage area for rainwater sewers, fixing line, determing the outlet location; dividing designed tube segment, calculating each pipe segment design discharge; rain hydraulic Computation conduct rainwater pipe channels cut to divert force calculation, and determine the diameter, slope, and flow rate and burial depth design parameters; draw rainwater pipeline plan and longitudinal section diagram. KEY WORDS:Drainage system, Piping layout, Design parameters, hydraulic calculation

某18层高层建筑给排水设计计算书

给水排水部分 一、 生活给水部分 系统分区:I 区:D3F~2F ;II 区:3F~9F :III 区:10F~18F ; 1.I 区:生活给水 当量数量小计流量 管径N ∑N l/s mm 洗手盆12323淋浴器0.7510.75洗涤盆166坐式大便器0.542蹲式大便器619114开水间100小便斗0.5 10 5 合计 150.75 3.683409 总当量:∑=75.150N 流量: s l q /98.3= 管径:DN65 II 区:生活给水 当量数量小计流量管径N ∑N l/s mm 洗手盆15656淋浴器0.7500洗涤盆11414坐式大便器0.500蹲式大便器600开水间100小便斗0.5 0合计 70 2.50998 总当量:∑=70N 流量: s l q /51.2= 管径:DN50 III 区:生活给水 当量数量小计流量管径N ∑N l/s mm 洗手盆17272淋浴器0.759 6.75洗涤盆11818坐式大便器0.500蹲式大便器600开水间100小便斗0.5 0合计 96.75 2.950847 总当量:∑=75.96N 流量: s l q /95.2= 管径:DN65

2.中水回用水系统分区:I区:3F~9F;II区:10F~18F; I区:中水回用水 当量数量小计流量管径 N∑N l/s mm 洗手盆100 淋浴器0.7500 洗涤盆100 坐式大便器0.500 蹲式大便器656336 开水间100 小便斗0.52814 合计350 5.612486总当量:∑=350 N流量:s .5 61 =管径:DN80 q/ l 两根立管,每根DN65 II区:中水回用水 当量数量小计流量管径 N∑N l/s mm 洗手盆100 淋浴器0.7500 洗涤盆100 坐式大便器0.513 6.5 蹲式大便器668408 开水间100 小便斗0.53618 合计432.5 6.23899总当量:∑=432 N流量:s =管径:DN80 .6 q/ l 24 3.直饮水系统分区:I区:2F~9F;II区:10F~18F; I区:直饮水 当量数量小计流量管径 N∑N l/s mm 洗手盆0.7500 淋浴器0.7500 小便斗0.500 洗菜池100 开水间11414 洗衣机100 洗涤盆100 坐式大便器600 坐式大便器0.500 合计14 1.12

相关文档