标准化作业指导书在配网工程中的应用

合集下载

10kV及以下配网更换电杆、横担、绝缘子标准化作业指导书

10kV及以下配网更换电杆、横担、绝缘子标准化作业指导书

10kV及以下配网更换电杆、横担、绝缘子标准化作业指导书
四川荥经电力有限责任公司
______供电所
年月
10kV及以下配网更换电杆、横担、绝缘子
标准化作业指导书
会签单
批准:
会签人员:
编写:
10kV及以下配网更换电杆、横担、绝缘子标准化作业指导书
1.适用范围
本作业指导书适用于更换_______________________电杆工作。

2.人员配置
3 .主要工器具
注:所需工器具的型号及数量根据工程实际需要选用4.主要材料
注:所需材料的型号及数量根据工程实际需要选用
- 5 -
- 6 -
- 7 -
- 8 -
- 9 -
6.现场作业工序工艺质量记录卡
- 10 -。

标准化作业指导书模板

标准化作业指导书模板

标准化作业指导书
1
配网抢修标准化作业指导书配电运检督查组
前言
随着城市低压电网建设的不断完善, 用户对电的需求日益增长, 配电运捡督察组抢修班承担了大同市0.4kv电力服务的任务。

近年来, 随着用电需求的加大, 作为供电企业优质服务的形象代表, 担负着大同市0.4kv电网的维护管理、电力营销和客户服务等工作, 任务艰巨, 责任重大。

但由于各种原因, 抢修人员安全意识、工作技能等尚不能完全适应新形势的要求。

为适应发展的需要, 提高人员素质, 规范管理, 进一步加强和规范抢修人员现场作业行为, 降低安全风险, 提高工作质量, 保证作业人员安全, 配电运捡督察组低压抢修班依据电力行业内有关的技术标准和安全规定, 并结实际情况和多年维护经验, 组织编写了配网抢修标准化作业指导书
目录
前言 (1)
1.更换低压接户线作业标准 (3)
2 更换低压引线作业标准 (6)
3.更换进户线作业标准 (8)
4.更换配电变压器高压跌落保险丝作业标准 (10)
5 更换配电变压器低压保险作业标准 (12)
6.更换用户端剩余电流动作保护器作业标准 (14)
7.停电更换表箱内部接线作业标准 (15)
1
1.更换低压接户线作业标准
2
3。

500V及以下配网施工标准化作业指导书

500V及以下配网施工标准化作业指导书

500V及以下配网施工标准化作业指导书1. 概述本文档旨在提供关于500V及以下配网施工的标准化作业指导。

通过遵循这些指导,可以确保配网施工的安全性、效率和质量。

2. 安全要求- 施工人员必须穿戴符合安全标准的个人防护装备,并接受相关安全培训。

- 施工现场必须清理整洁,不存在障碍物或危险物。

- 施工过程中应注意使用正确的工具,并确保其良好维护和更新。

- 施工人员在施工区域内必须遵守安全规定,包括限制进入未授权人员和正确操作设备的要求。

3. 施工流程以下是500V及以下配网施工的基本流程:3.1 现场勘测在开始施工之前,必须进行现场勘测,以确定合适的配线路径和设备安装位置。

勘测人员应按照相关标准和规定进行勘测,并记录必要的测量数据和现场要素。

3.2 器材准备根据勘测结果,准备所需的配网器材和设备。

确保所选购的器材符合相关的技术规范和标准,并具备必要的认证和检测报告。

3.3 安装施工按照设计要求和施工图纸进行电缆敷设、接线和设备安装等工作。

施工人员应仔细阅读和理解施工图纸,并按照规定的工艺和操作规程进行施工。

3.4 检验验收在施工完成后,进行配网设备的检验和验收。

检验要求包括设备的机械性能、电气性能和绝缘性能等。

验收过程应由专业人员进行,并做好相应的记录和报告。

4. 质量控制为确保施工的质量,应采取以下措施:- 建立质量管理制度,明确质量责任和职责。

- 进行施工前、施工中和施工后的质量检查。

- 对不合格的施工进行整改和复检,确保问题得到解决和纠正。

- 做好施工过程的质量记录和实时跟踪。

5. 文件管理- 按照相关规定,对施工的关键文件进行管理和归档。

- 使用标准化文件格式,确保文件的易读性和一致性。

- 对施工过程中的重要文件进行备份和存档,以防丢失和损坏。

6. 后续维护完成施工后,应及时进行配网的运行测试和维护。

检查设备的运行情况,修复和更换故障设备,并定期进行维护保养。

7. 总结本文档提供了关于500V及以下配网施工的标准化作业指导。

供电所标准化作业指导书

供电所标准化作业指导书

供电所标准化作业指导书一、前言。

供电所是电力系统中的重要组成部分,其作业标准化对于保障电力系统的安全稳定运行具有重要意义。

本指导书旨在规范供电所的作业流程,提高作业效率,确保供电所作业的安全可靠。

二、作业人员管理。

1. 作业人员应具备相关的电力知识和作业技能,经过专业培训并取得相应资质证书方可从事供电所作业。

2. 作业人员应严格遵守作业规程,服从现场指挥,做到有章可循、有序作业。

3. 作业人员应定期接受安全培训和演练,提高应急处置能力,确保在突发情况下能够迅速有效地应对。

三、作业流程规范。

1. 供电所作业前,应对作业场所进行全面检查,确保设备完好,作业环境安全。

2. 作业人员应按照作业指导书的要求进行作业,严格遵守操作规程,杜绝违章操作的发生。

3. 作业结束后,应对作业场所进行清理,归档作业记录,及时报告作业情况。

四、安全防护措施。

1. 作业人员应穿戴符合规定的防护用具,做好个人防护。

2. 作业现场应设置明显的安全警示标识,确保作业人员和周围人员的安全。

3. 作业过程中应加强对电气设备的监控,及时发现并排除安全隐患。

五、作业质量监控。

1. 供电所作业应建立健全的质量监控体系,对作业过程进行全程监控和记录。

2. 对于作业中出现的问题和隐患,应及时进行整改和处理,确保作业质量。

3. 定期对供电所作业进行检查和评估,总结经验,不断改进作业流程,提高作业质量。

六、总结。

供电所作业是一项重要的工作,作业规范化对于保障供电所的安全稳定运行至关重要。

作业人员应严格遵守作业规程,做到安全第一,质量第一,确保供电所作业的安全可靠。

希望本指导书能够成为供电所作业的有力参考,推动供电所作业标准化的深入推进。

以上就是对供电所标准化作业指导书的详细内容,希望能够对您的工作有所帮助。

10kV及以下配网更换电杆、横担、绝缘子准则化作业指导方案

10kV及以下配网更换电杆、横担、绝缘子准则化作业指导方案
编制标准卡
根据查勘情况、施工方案进行编制。
申请停电
按施工任务,根据查勘情况,确定停电时间,并向调度办理停电申请。
通知用户
停电申请批准后,由调度直接或指定专人,提前7天通知用户停电时间。
办理工作票
根据工作内容和查勘情况,填写并办理工作票。
准备材料
1、绝缘子
(1)根据工程需要准备绝缘子
(3)瓷件和铁件结合紧密,铁件镀锌完好
起吊原旧电杆
1.绑好电杆的风绳。
2.挂好钢丝套,钢丝套应套在电杆的合适位置,并理顺葫芦的掉链和拉链。
3.缓慢收动拉链,让葫芦略受力后进行各受力点的检查。
安装人字葫芦架
1、在葫芦架两旁与葫芦架根部相距10米处的地方打好锚桩
2、安装葫芦架的临时拉绳
3、起立人字葫芦架,并调整好拉绳
打入泥土的锚桩深度必须超过葫芦架杆长的1/6,用作拉绳的钢丝绳和所有的钢丝套的横截面不得小于50mm2,葫芦的载重能力应比电杆的重量大1倍
飞桩伤人
葫芦架的拉绳不得固定在有可能移动或其他不可靠的物体上。拉绳绑扎工作应由有经验的人员担任。
10kV及以下配网更换电杆、横担、绝缘子
标准化作业指导书
四川荥经电力有限责任公司
______供电所
年月
10kV及以下配网更换电杆、横担、绝缘子
标准化作业指导书
会签单
批准:
会签人员:
编写:
10kV及以下配网更换电杆、横担、绝缘子标准化作业指导书
1.适用范围
本作业指导书适用于更换_______________________电杆工作。
(4)瓷釉表面光滑、完整,无气泡、斑点、烧伤和缺釉现象
2、水泥杆
外表光滑、平整,内外壁均匀不露筋、不跑浆、保护层不应严重脱落,凸凹不平不应大于3mm;杆身弯曲不超过杆长的1/1000;无纵向裂纹,横向裂纹宽度不超过0、5mm,长度不超过1/3周长。

配网标准化作业(工作负责人)

配网标准化作业(工作负责人)

4
工作前准备
二、工作前准备包括: 1、现场查勘。 2、编制标准化作业文本。 3、材料及工器具准备。 4、作业信息发布。 5、作业前培训。
5
工作前准备
1、现场查勘 配电检修施工作业,均应组织现场勘察,并填写现场勘察 记录表。 配电线路现场勘察一般由工作负责人组织有关人员参加。 (小组工作负责人、工作票签发人、工作许可人、施工队队长 等) 现场勘察内容: 作业现场的设备现状(包括设备缺陷、设备运行方式等); 作业现场设备需要停电的范围、保留的带电部位; 作业现场附近有无邻近带电设备,以及距带电设备距离;
配网标准化作业
二0一三年十二月
标准化作业
标准化作业是为了强化生产现场管理,规范生产现场作业 人员行为和生产流程。真正实现生产现场的规范化、标准化和 程序化按照电力安全生产有关法律法规、技术标准、规程规范 的要求,对电力生产现场的作业活动全过程进行细化、量化、 标准化和程序化,保证作业过程处于“可控、在控”状态,不 出现偏差和错误,以获得最佳效果和秩序与效果。 配网现场标准化作业是指对配电设备运行、巡视、检修、 抢修、试验等现场生产作业全过程为主要内容,按照安全生产 的客观规律与要求,制订作业程序和工艺标准的一种有组织的 活动。 开展现场标准化作业应本着“统一流程、规范作业、结合 实际、持续完善”的指导思想,密切联系工作实际,做好与现 有安全管理、生产管理、技术管理机制的有效衔接与融合,确 保现场作业任务清楚、作业程序清楚、危险点清楚、安全措施 清楚,人员到位、措施到位、执行到位、监督到位。
14
现场作业
四、现场作业 生产作业现场一般应具备下列资料: 1、现场勘察报告 2、现场标准化作业指导书 3、工作票 作业人员到达作业现场后,正式开工前。工作负责人应 针对现场情况,认真讲解工作票、标准化作业指导书载明的 作业内容、时间、作业工序、作业方法、质量标准、危险点 分析、安全措施等主要内容进行工作前“站队三交”。

第8部分 配网工程(作业指导书)

第8部分 配网工程(作业指导书)
2. 桩锚必须牢固可靠,并设专人看管
1. 抱杆根开应选抱杆高度的 0.4 倍; 2. 抱杆倾角应小于 15°
1. 应按安全系数选取钢丝绳及卸扣; 2. 不得使用断股或受损超标的钢丝绳
1. 钢丝绳与抱杆、桩锚连接应牢固可靠; 2. 按安全系数选取钢丝绳及卸扣; 3. 桩锚必须设专人看管
中等风险
应按起吊重量及安全系数选取滑轮组
编码:DLGT-02
10
PWJX-01 横担、金具及绝缘子安装作业指导书
目次
1 适用范围 ·························································································································································11 2 编写依据 ·························································································································································11 3 作业流程图 ·····················································································································································11 4 安全风险辨析与预控 ·····································································································································11 5 作业准备 ························································································································································ 13 6 作业方法 ·························································································································································· 6 7 质量控制措施及检验标准 ······························································································································ 9

10KV及其以下配网施工标准化作业指导书

10KV及其以下配网施工标准化作业指导书

10KV及以下配网施工标准化作业指导书编写:年月日审核:年月日批准:年月日作业负责人:_____________________________宁夏城农网电力服务有限公司1、适用范围本作业指导书适用于10KV及以下配网施工作业。

对施工人员在10KV及以下配网工作进行指导,从而保证10KV及以下线路、设备安全可靠运行。

2、引用文件SD—292架空配电线路及设备运行规程《国家电网公司电力安全工作规程》(电力线路部分)(试行)3、工作前准备3.1准备工作安排1、工作负责人了解核实现场工作状况;对于需要开挖的地方一定要提前了解地下有无电缆、光缆、自来水管、天然气等;2、工作人员检查工器具、劳动防护用品等是否齐全合格;3、工作负责人在作业现场向作业班成员宣读工作票,交待安全、技术措施及注意事项;4、工作班成员应认真听取工作票作业内容,注意安全措施、技术措施是否完备,如有建议或不同意见应及时提出;5、明确工作任务,按工作计划施工;6、工作人员认真准备工器具、材料。

施工材料需选用相应规格型号的材料,严禁以小代大。

3.2人员要求1、作业人员必须熟练掌握本专业作业技能及《电业安全工作规程》知识,经年度《电业安全工作规程》考试合格,持有本专业职业资格证书;2、作业人员应身体健康、精神状态良好,思想稳定,心态正常;如不适应施工现场要求,工作负责人必须对作业人员进行适当调整;3、现场工作人员必须带安全帽、穿工作服、绝缘胶鞋;4、进入施工现场工作,必须有监护人,监护人原则上不得做其他工作及擅离作业现场;5、每个参加工作的人员应明确工作过程、质量要求、工艺方法、危险点及注意事项;6、在作业过程中,所有从人员严禁吸烟,嬉笑打闹。

3.3施工现场注意事项1、工作现场必须全封闭装设安全防护围栏。

工作车辆应停在安全位置,必要时工作车辆周围应设安全警示标志;2、作业人员必须正确佩戴安全帽;3、工作人员在工作票指定的工作区域施工,施工人员不得擅自到工作票以外的范围工作;4、上杆前应检查杆根、拉线,杆塔埋深是否符合要求(杆身表面光洁平整,漏筋、跑浆、蜂窝等现象,杆身不得有纵向裂缝,横向裂缝宽度不超过0.1mm长度不超过1/3周长,且1m内横向裂纹不得超过三处,杆身弯曲度不超过1/500),对脚扣进行冲击实验。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

标准化作业指导书在配网工程中的应用
发表时间:2019-11-15T13:58:01.733Z 来源:《基层建设》2019年第23期作者:吴晓东
[导读] 摘要:随着地方经济的迅猛发展,电网建设快速增长,配网工程量不断扩大,配网施工队伍越来越多,配网工程的安全管理问题和工程质量问题也不断凸显出来。

包头供电局九原分局内蒙古包头市 014060
摘要:随着地方经济的迅猛发展,电网建设快速增长,配网工程量不断扩大,配网施工队伍越来越多,配网工程的安全管理问题和工程质量问题也不断凸显出来。

如何保证在完成大量的配网工程的同时确保人身安全和工程质量,给供电企业的工程管理提出了新的挑战。

本文以实行标准化作业为切入口,将标准化作业指导书应用于配网工程实施建设过程中,通过标准化来规范施工过程中的安全管理和工程质量,从而实现配网工程安全可靠、保质保量完成的目的。

关键词:配网工程;标准化作业;实施对策
引言:目前供电企业在配网工程实施过程中,由于施工环境复杂,施工人员综合素质和作业水平参差不齐,在施工过程中对于作业人员的施工安全和工程的质量很难得到有效的管控。

这就要求供电企业在配网建设过程中采取有效的管理措施来强化工程管理,因此引入标准化作业理念,通过使用现场标准化作业指导书(卡),使工程实施过程中具有严、细、实的执行作业方案,彻底解决配网工程实施过程存在的问题。

1标准化作业指导书(卡)简介
标准化作业指导书(卡)按照对每项施工作业全过程控制的要求,对作业计划、前期准备、实施过程、事后总结等各个环节明确具体操作的方法、步骤、措施、标准和人员责任,严格按照工作流程执行。

现场标准化作业体现了“四个凡事”、“四个结合”和“四化”,“四个凡事”即凡事有人负责、凡事有章可循、凡事有据可查、凡事有人监督;“四个结合” 即:一是与各部门和各岗位日常工作及职责范围相结合;二是与生产运行管理相结合;三是与安全管理细致化相结合;四是与供电所规范化管理相结合;“四化”即:作业具体化,人员明确化,责任直接化,过程程序化;
标准化作业指导书与标准化作业指导卡的区别在于标准化作业指导书的使用范围主要为年度、月度计划中所列技改、大修工作、预防性试验、计划检修、设备巡视等工作项目操作;而标准化作业指导卡的使用范围主要为非计划性的临时检修、单一设备的消缺、更换设备的零部件和急修等工作,以及危险性相对较小的作业项目。

2标准化作业指导书(卡)的信息系统化
前期的标准化作业指导书(卡)主要以手工编写为主,在应用实施中存在很多不足之处:一是标准化作业指导书(卡)处于手工编写阶段,不能更好地满足信息化的发展需求;二是程序繁琐,执行不流畅,一般人员操作不便;三是标准化作业指导书填写内容十分多,前期的准备比较费时费力;四是指导书数据库不完善。

因此,必须建立一套计算机《配电现场标准化作业辅助系统》,以便于标准化作业的有效实施,使工作负责人可以直接登陆到系统里面进行指导书(卡)的编写,既简单又快捷,可以极大的提高指导书(卡)的编写速度,从而保证配网工程现场标准化作业的顺利实施。

3标准化作业指导书(卡)的执行流程
标准化作业指导书(卡)的执行可分为三个阶段,以新建变台工程为例,首先是准备阶段:施工单位网上接收生产技术组下达的施工任务书后,根据任务内容明确执行本次任务的工作班组和负责人,工作票签发人组织负责人、安全员和施工人员进行现场勘测,确定作业施工方法,并进行危险点分析;然后办理停电申请,经批准后,网上编制三措、工作票和危险点预控票,工作负责人依据现场勘查情况进入辅助系统编制作业指导书,并履行审批和签发手续,待审批和签发后,组织工作班成员召开班前会,学习标准化作业指导书,并进行技术交底,明确任务的分工情况、相应的职责和工艺标准,然后按指导书去材料库和工器具库领取所需规格数量的材料及工器具,并进行出库前检查,领出的材料及工器具按车辆定置摆放图放置在车上后前往现场。

其次为作业阶段:进入现场后工作负责人与安全员现场复勘,查看确无新的危险点出现,然后与许可人办理停电许可手续,由许可人执行停电倒闸操作,此时工作负责人组织工作班成员按照定置图及围栏图布置现场,将材料及工器具进行分类摆放。

工作负责人接到工作许可人已停电的命令后,组织工作班成员采取现场安全措施,布置完后,通知工作许可人,得到许可开始工作命令后,工作负责人组织人员列队宣读作业指导书、工作票及危险点预控票内容,并履行签字确认手续,正式开工后,作业人员按照安装内容、步骤及工艺标准依次进行,工作负责人及安全员现场认真监护作业人员的人身安全,同时监督作业过程及工程的质量;
最后为总结、考核阶段:工作结束后工作负责人组织作业人员进行工程自检,现场对每项作业按照分工情况进行考核签字,按照工作安全、劳动纪律、技术标准及工艺标准进行考核,自检、考核过程结束后,工作负责人组织人员拆除现场安全措施,清点人数,清点工器具及材料后装车,工作负责人向工作许可人作终结报告,工作许可人恢复送电,送电运行正常后,作业班组返回单位,并办理工器具入库及材料退还手续;完毕后,工作负责人组织召开班后会,对此次标准化作业指导书执行情况进行评估,将存在问题及改进意见记录在作业指导书上,并填写隐蔽工程图与验收总结,会后将作业指导书归档。

4标准化作业指导书(卡)的应用效果
通过应用标准化作业指导书(卡),建立配网工程标准化作业体系,切实提高了施工现场的安全管理水平,有效地确保了作业过程中人身和设备安全,使施工作业实现了动态管理,有效提高了工程质量。

主要效果包括:一是增强了职工的安全意识,提高了职工的业务技能水平。

自实施标准化作业以来,通过事前查找作业中危险点,事中采用标准化流程的控制,有效地杜绝了因施工方法不正确发生的违章现象。

另外通过对辅助系统的不断学习、完善,不仅提高了作业指导书的质量、拓宽了应用的范围,更为作业人员提供了很好的现场教育机会,自然形成了“工作学习化,学习工作化”的良好氛围。

二是提高了劳动效率。

实施现场标准化作业管理以后,切实规范了工作流程,理顺了管理关系,减少了重复劳动,节约了劳动成本。

三是通过作业指导书内明确的任务分工和现场考核,不仅提高了人员的责任意识,而且为工程质量终身制提供了最有效的原始资料,同时也将绩效考核延伸到了的现场。

另外每一项作业执行的现场标准化作业指导书,也为工程管理、运行管理和设备管理填补了一种必备的一手资料。

总结:标准化作业指导书(卡)通过分析工程中存在的不安全因素和施工过程各环节暴露出的问题,以现场安全和工程质量为主线,使配网工程全过程实现可控、在控,大大加强和规范了施工现场的管理。

随着电网规模的不断扩大和新技术新设备的应用,标准化作业将
不断持续改进,使配网工程的实施更加规范化,实现工程安全管理和质量管理有效管控。

参考文献:
[1]任东博.配网工程施工中的安全风险管理措施[J].科学技术创新,2019(25):161-162.
[2]陈淙达.10 kV配网工程施工管理及质量控制探讨[J].通信电源技术,2019,36(08):255-256.
[3]高建林,李亚卫,鲍云龙.电力配网工程施工技术分析[J].通信电源技术,2019,36(08):100-101.。