LG洗衣机XQB42-38产品说明书
LG 洗衣机说明书.pdf_1701664577.6391237

LIMITED WARRANTYUSATERMS AND CONDITIONSARBITRATION NOTICE: THIS LIMITED WARRANTY CONTAINS AN ARBITRATION PROVISION THAT REQUIRES YOU AND LG ELECTRONICS (“LG”) TO RESOLVE DISPUTES BY BINDING ARBITRATION INSTEAD OF IN COURT, UNLESS YOU CHOOSE TO OPT OUT. IN ARBITRATION, CLASS ACTIONS AND JURY TRIALS ARE NOT PERMITTED. PLEASE SEE THE SECTION TITLED “PROCEDURE FOR RESOLVING DISPUTES” BELOW.Should your LG Vacuum Cleaner (“Product”) fail due to a defect in materials or workmanship under normal and proper use, during the warranty period set forth below, LG will, at its option, repair or replace the Product. This limited warranty is valid only to the original retail purchaser of the Product (“You”) and applies only when purchased lawfully and used within the United States including U.S. Territories.•Replacement Products and parts are warranted for the remaining portion of the original warranty period or ninety (90) days, whichever is greater.•Replacement Products and parts may be new, reconditioned, refurbished, or otherwise factory remanufactured.•Replaced Product or part(s) will be the property of LG.•Proof of original retail purchase specifying the Product model and date of purchase is required to obtain warranty service under this limited warranty.•Warranty start date will be ninety (30) days from manufacture date absent valid proof of purchase .E XCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THE PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THE ABOVE LIMITED WARRANTY. UNDER NO CIRCUMSTANCES SHALL LG OR ITS U.S. DISTRIBUTORS/DEALERS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, CONSEQUENTIAL, SPECIAL, OR PUNITIVE DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST GOODWILL, LOST REVENUES OR PROFITS, WORK STOPPAGE, IMPAIRMENT OF OTHER GOODS, COST OF REMOVAL AND REINSTALLATION OF THE PRODUCT, LOSS OF USE, OR ANY OTHER DAMAGES WHETHER BASED IN CONTRACT, TORT, OR OTHERWISE. LG’S TOTAL LIABILITY, IF ANY, SHALL NOT EXCEED THE PURCHASE PRICE PAID BY YOU FOR THE PRODUCT.SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.THIS LIMITED WARRANTY DOES NOT COVER:•Service trips to deliver, pick up, install, or clean, or to correct wiring or unauthorized repairs.•Service trips to educate how to assemble, operate, or maintain the Product.•Damage or failure of the Product to perform during power failures and interrupted or inadequate electrical service.•Damage or failure of the Product resulting from operating the Product in a corrosive atmosphere or contrary to the Product owner’s manual.WARRANTY PERIODServiceReturnN o return allowance Parts and Labor (internal/functional parts only)Six month from the date of original retail purchase•Damage or failure of the Product caused by accidents, pests and vermin, lightning, wind, fire, floods, acts of nature, or any other causes beyond the control of LG.•Damage or failure of the Product caused by unauthorized modification or alteration, or if the Product is used for other than the intended purpose.•Damage or failure of the Product caused by incorrect electrical current or voltage.•Damage or failure of the Product caused by transportation, storage, and/or handling, including scratches, dents, chips, and/or other damage to the finish of the Product, unless such damage is reported within one (1) week of delivery.•Damage or missing items to any display, open box, or discounted Product.•Any Product sold “As Is”, “Where Is”, “With all Faults”, or similar disclaimer.•Products with original serial numbers that have been removed, altered, or cannot be readily determined.•Increases in utility costs and additional utility expenses.•Any noises associated with normal operation.•Products used for other than normal and proper household use (e.g., commercial or industrial use, offices, and recreational facilities or vehicles) or contrary to the Product owner’s manual.•Costs associated with removal and reinstallation of the Product for repairs.•Replacement of batteries, filters, or any consumable parts.•The removal and reinstallation of the Product if it is installed in an inaccessible location or is not installed in accordance with the Product owner’s manual.•Damage or failure of the Product resulting from misuse, abuse, improper installation, repair, or maintenance. Improper repair includes the use of parts not authorized by LG. Improper installation or maintenance includes installation or maintenance contrary to the Product owner’s manual.•Damage or failure of the Product caused by the use of parts, components, accessories, consumable cleaning products, detergents, chemicals, or any other products or services that are not authorized by LG.The cost of repair or replacement under these excluded circumstances shall be borne by You.TO OBTAIN WARRANTY SERVICE AND ADDITIONAL INFORMATIONCall 1-800-243-0000 and select the appropriate option from the menu.Or visit our website at Or by mail: LG Electronics Customer Service P.O. Box 240007 Huntsville, AL 35813 ATTN: CIC。
lg自动洗衣机说明书

lg自动洗衣机说明书----afb511bf-7229-11ec-8748-7cb59b590d7d篇一:lg波轮式洗衣机洗衣特点LG波轮洗衣机洗涤功能:微电脑控制洗涤烘干功能,省时省力。
缺点:耗电耗水。
海尔通常是中国波浪轮洗衣机品牌的首选,因为海尔已经成为波浪轮的第一品牌。
其次,在松下、LG、夏正确安装全自动洗衣机后,具体操作和使用方法如下:(1)插上电源插头,放下或连接排水管,打开水龙头,将待洗衣物、洗衣粉和添加剂(软化剂、漂白剂等)放入洗衣机,盖上盖子;(2)由于具有加热功能,滚筒洗衣机能更好地使用效率高、沸水低的洗衣粉。
优点是泡沫底部不会溢出桶lgwd-n12155d。
正确的操作是:轻触龙头-插入-将洗衣粉放入洗衣粉-穿上衣服-按下电源按钮-按下启动。
这是最标准的操作员。
一般来说,你说的不会有问题。
你说有两种可能会漏水:第一,洗衣机的水龙头和墙壁的内线连接不紧。
水龙头或内部电线可能有问题,或者没有原料带。
2、洗衣机水龙头与洗衣机进水管连接不好。
建议仔细阅读说明书。
根据正确的说明,建议您首先检查进水管是否堵塞,操作是否正确。
如果没有问题,请拨打售后维修电话咨询,LG专业人员会为您解决。
售后电话:400-819-9999。
洗衣机水龙头通常是通用的。
我不明白为什么它们不能普及。
如果不起作用,你能换一个进水管吗。
您可以随身携带LG配套的进水管,并与另一品牌的进水管配套,只要螺纹能匹配即可。
这样,水龙头就可以随意购买了。
此外,LG目前所有滚筒洗衣机都具有桶清洗功能能,你可以选择该程序,定期为洗衣机洗个“澡”,保持洗涤环境的清洁,lg蒸气洗衣机具有的杀菌防过敏功能,非常适合宝宝的衣服洗涤。
第二章:蒸汽清洗的时代即将来临-LG蒸汽清洗机lg其产业遍布家电、工业、生活用品等多个领域。
lg蒸汽洗衣机。
无论是针对衣物进行的杀菌除螨,还是清新护理工作,传统洗衣机都只能望洋兴叹。
蒸汽洗衣机,顾名思义,其特点是增加了一个蒸汽装置,这表明创造了一个全面的服装护理解决方案的消费者。
LG洗衣机说明书

桶转洗涤方式
当波轮运转时,洗衣机内桶以相反的方向转动,从而产生强有力的洗衣水流,提 高了洗衣效果。
模糊逻辑控制方式
洗衣机自动感知衣量,并设置最佳洗衣状 态,如水位、洗衣时间等。 电子控制系统采用了最先进的技术,确保提 供最佳洗涤效果。
要使正在工作中的洗衣机暂 停或改变程序,则再按动此键 工作指示灯由闪烁变常亮,再 按一次可恢复正常。
电源开关 0;<=6 6>> 8
用来开 : 关电源。
洗衣结束后 !# 秒钟或在暂停 状态下 !# 分钟后,电源自动 切断。
童锁 012345 4617 8
作用:锁定已设定的程序,且能锁定包括 电源开关的所有按键,防止洗衣机运行 中儿童误按改变程序。 开启:同时按下“设定”和“程序”两键。 状态:启动时伴有“叮叮”一声,此后显示 屏将每隔 % 秒显示“ ”,且能锁定包 括“电源开关”的所有按键。 关闭:再一次同时按下“设定”和“程序” 键或拔掉插头。
!"# $ %&#
安全方面的注意事项 ! 请务必遵守 "
警告
有可能触电
!. 请勿用湿手插 0 拔电源插头。 %. 保持电源插头清洁,勿用湿布
除尘。
有可能触电
!. 请单独使用 %%#1 2 ,34 以上 的三相电源插座。
%. 插座要可靠接地。
有可能触电
!. 除修理技术者外请不要随意拆 卸或改造洗衣机。
连接座
密封橡胶垫
进水阀口
进水管与水龙头的连接
! 一手拿着连接座,一手按住扣
环往下拉,将连接座与进水管
分开。
LG洗衣机说明

运输螺栓
洗衣机安装运输螺栓是为了防止运输途中的内部损坏 。
拆除运输螺栓
注 意
排水管固定装 置请勿拆卸
1. 为了防止运输途中的内部损坏 , 安装了 4 个
螺栓 , 在使用洗衣机前沿着运输螺栓橡胶 拆除这些螺栓 。 如果螺栓没有被拆除 , 可能会引起强烈的 振动 ,噪音和故障 。
3. 轻轻地扭动运输螺栓橡胶并沿着它拔出 4
请 不 要 洗 涤 防 水 性 衣 物 :雨 穴如 绒 服 帘 袋 等 披 、羽 、浴 、睡 雪。 能 洗 涤 可 以 机 洗 的 衣 物 ,如 2. 只 有 疑 问 遵 从 衣 物 上 的 洗 涤 ,请 指 南 标 识 。 不 要 洗 涤 带 护 纱 的 窗 帘 、台 3. 请 布 及 没 有 包 边 的 洗 涤 物 等 ,如 要 洗 涤 将 其 放 入 洗 衣 网 兜 ,请 内 洗 涤 。
1.
可 能 发 生 爆 炸
不 要 让 洗 衣 机 接 触 或 靠 近 热 源 火 香 烛 烟 :蚊 、蜡 、香 /明 穴如 等 雪。 不 要 将 洗 衣 机 放 在 下 2. 请 0℃ 以 的 环 境 下 露 在 户 外 或 湿 气 ,暴 大 的 地 方 使 用 。 勿 将 机 器 放 置 在 地 毯 上 使 3. 请 用 置 的 地 面 板 平 整 ,放 、 穴地 雪需 牢 固 。 使 用 低 泡 洗 衣 粉 。 4. 请
洗衣盆
环境清扫 :
对墙 、门和地板的清扫是必需的 。
大约 2cm
穴10cm押后 / 2cm押右 & 左边雪 * 安装在坚硬平整且有地漏的表面 , 请勿安装在柔
软的毛毯或木质地板上 。
*不 要 将 要 洗 的 衣 服 或 其 它 物 品 放 在 洗 衣 机 顶 盖
上 ,这会影响洗衣机的运行 。
LG 洗衣机说明书.pdf_1702072068.103111

Type of laundryObserve the manufacturer's instructions on the care labelCleaning agent Prewash Main wash Sof-tener Easy-iron For normally to heavily soiled cotton laundry. The most economical programme at 40 °C and 60 °C in terms of combined water and energy consumption.iYesiiFor heavily soiled and robust laundry made of cotton, synthetic fibres and blends. Economical energy consumption thanks to a prolonged washing time; ideal for running overnight to benefit from lower energy tariffs. To avoid the noise of a spin cycle at night, select "Rinse hold" and start the spin cycle in the morning, or set an appropriate programme start time using the "Start in" function. Use a laundry bag for items made primarily with synthetic fibres.–Yes i –For easy-care fabrics, e.g. made of cotton, linen, synthetic fibres or blends.i Yes i i For mixed loads of cotton and synthetic fabrics. For lightly soiled items without stains.–Yes i –For delicate items which are suitable for machine washing (cotton, synthetic fibres and blends, etc.), e.g. curtains. No spin between the rinse cycles.i Yes i –For delicate, washable items, e.g. made of silk, satin, synthetic fibres or blends (e.g. silk blouses, silk scarves). Use a detergent which is suitable for delicates and/or silk.–Yes i –Yes i i TABLE OF PROGRAMMESACD B EFGHJKLMN Ioff and the "Lid open" indicator lights up.• After around 15 minutes, the washing machine switchesoff completely in order to save energy.1. Turn the programme switch to the "Off" position.2. Turn off the water tap.3. Open the lid and drum, and unload the washingmachine.4. Leave the lid open for a short while so that the inside ofmuch detergent was used. Use less detergent for the being able to change the settings for an active programme. It cannot be activated or deactivated if the programme selector is in the "Off/O" position. To activate the childproof lock:• Turn the program selector switch to a programme, orallow a programme to run as usual.• Press the two buttons marked with keys simultaneously,and hold for at least 3 seconds. The key symbol on the display indicates that the childproof lock is activated.The programme settings can no longer be changed. The only change still possible is to switch off the appliance by turning the programme selector to the "Off/O" position. To deactivate the instruction manual ("Faults and what to do about them")."Water tap closed":Insufficient or no supply water."Service":Fault or malfunction in one of the electrical components."Clean pump":The water is not drained.programme. The indicator flashes.2. Select a new programme, options and another spinspeed, if desired.3. Press the "Start (Pause)" button again. The newprogramme starts at the same point at which the previous programme was interrupted. Do not add reaches the end. Press the "Delete" button for at least 3 seconds. Any water present is drained away; it can take a while until the lid can be opened.5019 600 000579000827643。
LG 洗衣机用户手册说明书

NOTE:Read the entire instruction manual before starting the installation.SAFETY CONSIDERATIONSImproper installation,adjustment,alteration,service,maintenance,or use can cause explosion,fire,electrical shock or other conditions which may cause personal injury or property damage.Consult a qualified installer,service agency,or your distributor or branch for information or assistance.The qualified installer or agency must use factory-authorized kits or accessories when modifying this product.Refer to the individual instructions packaged with the kits or accessories when installing.Follow all safety codes.Wear safety glasses and work e quenching cloths for brazing operations.Have fire extinguisher available.Read these instructions thoroughly and follow all warnings or cautions attached to the unit.Consult local building codes and National Electrical Codes (NEC)for special requirements.It is important to recognize safety information.This is the safety-alertsymbol.When you see this symbol on the unit and in instructions or manuals,be alert to the potential for personal injury.Understand the signal words DANGER,WARNING,CAUTION,and NOTE.These words are used with the safety-alert symbol.DANGER identifies the most serious hazards which will result in severe personal injury or death.WARNING signifies hazards which could result in personal injury or death.CAUTION is used to identify unsafe practices,which would result in minor personal injury or product and property damage.NOTE is used to highlight suggestions which will result in enhanced installation,reliability,or operation.WARNING:Before installing or servicing system,always turn off main power to system.There may be more than one disconnect switch.Turn off accessory heater power if applicable.Electrical shock can cause personal injury or death.CAUTION:This coil contains Nitrogen precharge of 15PSIG.Release of this pressure through the center of the rubber plugs is required before removing the plugs.Failure to follow this CAUTION could result in minor personal injury or product and property damage.IMPORTANT:Nitrogen can leak out through the needle pierce hole in the plugs.This does not indicate a leaking coil nor warrant return of the coil.Fig.1—Model CK3B Furnace CoilA96318Installation InstructionsCK3BCased Horizontal Furnace Coil→→INTRODUCTIONThe CK3B is a horizontal,multi-use cased furnace coil.(See Fig.1.)With the use of field-supplied transition duct,these furnace coils can also be applied to other similar horizontal furnaces on the market.The CK3B is available in sizes 024through 060.(See Fig.2.)NOTE:Models with tin-plated copper coils (″T ″in the 10th position of the model number)are installed the same as standard copper coils.INSTALLATIONThe unit can be installed on a work platform,secured to roof truss in an attic,suspended from hangers on floor joists in crawl space,or installed on blocks.It is designed to allow airflow in either direction,to mate with horizontal-left (see Fig.5)or horizontal-right (see Fig.6)furnace installations.NOTE:Before placing ductwork on casing opening,check the rubber grommet (see Fig.3)to ensure that the grommet is located so the bottom end is within the condensate pan.Moisture on the header tube will run down the grommet and drip into the pan.NOTE:Remove shipping brace from both ends of casing prior to installation.Also remove corrugated shipping block from inside the right end of casing prior to installation.PROCEDURE 1—FURNACE ATTACHMENTA.Attach coil to furnace.The attachment plates (3)and filler plate (1)are packaged together and placed in coil carton.Remove these items,verifying the correct e the following procedure to attach CK3B horizontal coil to furnace.1.Three attachment plates are used to attach coil to furnace.Application determines which end of the coil will be attached to the furnace.e self-tapping screws to mount attachment plates to coil casing.(See Fig.4A.)3.Connect furnace snugly against coil casing.e self-tapping screws to attach furnace.(See Fig.4B.)5.Seal joint between coil casing and furnace to create air tight seal using locally approved materials.Note:For the 10th digit position in the model number,0=standard copper coil and T =tin-plated copper coil.→Fig.2—Dimensional DrawingUNITA (IN.)B (IN.)C (IN.)D (IN.)E (IN.)SHIPPING WEIGHT(LB)CK3BXA024(0,T)1717–9/1619–1/1610–1/165/81637.0CK3BXA030(0,T)1717–9/1619–1/1610–1/163/41640.5CK3BXA036(0,T)1717–9/1622–1/1610–1/43/41645.5CK3BXA042(0,T)2121–1/1622–1/1610–1/47/819–1/247.0CK3BXA048(0,T)2121–1/1622–1/1610–1/47/819–1/251.0CK3BXA060(0,T)2424–9/1628–1/813–3/167/82364.0A975213⁄FRONTRIGHT SIDEPROCEDURE 2—HORIZONTAL ATTIC INSTALLATION A.Construct work platform to support coil/furnace combination.1.Construct work platform,using material in platform that will support the weight of an installer or a service person.2.Place work platform in front of discharge end of furnace.3.Secure platform to building joists.B.Install coil.To suspend CK3B:1.Cut plumbers strap to desired lengths.2.Attach plumbers strap to 4corners of coil casing.(See Fig.7.)e a minimum of 2screws per corner to attach plumbers strap to casing.4.Position and secure coil in front of furnace discharge end.5.Make sure coil is level for proper condensate drainage.ing appropriate fasteners for duct type,connect supply-air duct to coil.7.Coils are shipped with a filler plate included in the package for use when coil is coupled with a narrow furnace.Attach filler plate between coil flange in furnace as shown in Fig.5and 6.PROCEDURE 3—HORIZONTAL CRAWL SPACE INSTALLATIONAs an alternate to horizontal attic installation,the CK3B horizontal coil can be installed in a crawl space by mounting on suitable blocks,pads or by hanging from floor joists.Fig.3—Grommet LocationA00188Fig.4—Duct Flange AssemblyA97201BTo suspend CK3B:1.Cut plumbers strap to desired lengths.2.Attach plumbers strap to4corners of coil casing(See Fig.7).e a minimum of2screws per corner to attach plumbers strap to casing.4.Position and secure coil in front of furnace discharge end.5.Make sure coil is level for proper condensate drainage.ing appropriate fasteners from duct type,connect supply-air duct to coil.PROCEDURE4—REFRIGERANT LINESRefrigerant lines must be configured per local building y out lines in relation to specifications and job site requirements. PROCEDURE5—CONNECT REFRIGERANT LIQUID AND SUCTION LINESFor matched and mismatched systems,use line sizes recommended in outdoor unit Installation Instructions.The coil can be connected to outdoor units using accessory refrigerant line sets or field-supplied lines of refrigerant grade.Always evacuate lines and reclaim refrigerant when making connections or flaring refrigerant lines.Leak check connections before insulating entire suction line.CAUTION:If unit is to be installed on system with a thermostatic expansion valve,removal of indoor coil piston is required.Failure to follow this CAUTION could result in minor personal injury or product and property damage.A.Suction LineSuction line is designed for field sweat connections.Provide inverted loop on suction line if line set exceeds50ft.per long line application guide. Sweat stub has a rubber shipping plug to keep out moisture and dirt.Remove plug only when ready to make field sweat connection.CAUTION:To avoid damage while brazing,wrap tubing or fittings with a heat-sinking material such as a wet cloth. Failure to follow this CAUTION could result in minor personal injury or product and property damage.B.Liquid LineLiquid line is designed for sweat connection.During installation these steps should be followed:1.Replace piston,if required.Check piston size stamped into side of brass hex nut.(See Fig.8.)If piston number does not match requiredpiston shown on outdoor unit rating plate,replace indoor piston with piston shipped with outdoor unit.2.When piston is replaced finger tighten plus1/4turn.CAUTION:Remove Teflon seal during brazing.Replace when fitting has cooled.Failure to follow this CAUTION could result in minor personal injury or product and property damage.3.Liquid stub has a rubber shipping plug to keep out moisture and dirt.Remove plug only when ready to make field sweat connection. SYSTEM REFRIGERANT CONTROLA refrigerant control device(bypass type)is factory supplied with coil.(See Table2.)The piston has a refrigerant metering hole through it,and is field replaceable.The piston shipped with indoor coil may be different from piston shipped with outdoor condensing unit.If this is the case,change the indoor piston. Always use piston shipped with outdoor condensing unit.PROCEDURE6—CONNECT CONDENSATE DRAIN LINEThe CK3B coil is designed to dispose of accumulated water through built-in condensate drain fittings.It is recommended that PVC fittings be used on the condensate pan.Do not over-tighten.Finger tighten plus1–1/2turns.Be sure to install plastic plug in unused condensate drain fitting.Fig.5—Horizontal Left Installation with Filler PlateA97203AIRFLOWCONNECTIONInstall a trap in condensate line as close to the CK3B coil as possible.Make trap at least 2–1/4in.deep and not higher than the bottom of unit condensate drain openings.(See Fig.9.)NOTE:If unit is located in or above a living space where damage may result form condensate overflow,a field-supplied,external condensate pan should be installed under the entire unit,and a secondary condensate line (with appropriate trap)should be run from unit into pan.Any condensate in this external condensate pan should be drained to a noticeable place.As an alternative to using an external condensate pan,some localities may allow the running of a separate 3/4–in.condensate line (with appropriate trap)to a place where condensate will be noticeable.The owner of the structure must be informed that when condensate flows from the secondary drain or external condensate pan,the unit requires servicing or water damage will occur.Fig.6—Horizontal Right Installation with Filler PlateA97037AIRFLOWCONNECTIONFig.7—CK3B Suspension with Plumbers StrapA97014Table 2—Refrigerant Metering DeviceMODEL CK3B COIL SIZEPISTON NUMBER024590306703670042780488406090Install traps in condensate lines as close to coil as possible.(See Fig.9.)Make sure that outlet of each trap is below its connection to condensate pan to prevent condensate from overflowing drain pan.Prime all traps,test for leaks,and insulate traps and lines if located above a living area.Consult local codes for additional restrictions or precautions.Fig.8—Refrigerant Control Device ComponentsA96248SIDE OF NUTHEX BODYFig.9—Condensate TrapA03087* OR TRAP TO LOCAL CODESERVICE TRAININGPackaged Service T raining programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including:• Unit Familiarization • Maintenance• Installation Overview • Operating SequenceA large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book.Classroom Service T raining plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog.CALL FOR FREE CA T ALOG 1-800-644-5544[ ] Packaged Service T raining [ ] Classroom Service T raining。