配电柜配置清单

合集下载

低压配电柜技术要求(标准版)

低压配电柜技术要求(标准版)

低压配电柜技术要求(标准版)Technical safety means that the pursuit of technology should also include ensuring that peoplemake mistakes( 安全技术 )单位:_________________________姓名:_________________________日期:_________________________精品文档 / Word文档 / 文字可改低压配电柜技术要求(标准版)一、设备采购清单序号设备名称型号外形尺寸(mm)数量(台)备注1低压配电柜GCS1000×800×2200122台主开关柜、12台电机馈线柜二、使用条件及标准规范:2.1遵循的主要现行标准,但不仅限于下列标准的要求:GB191《包装贮运标志》GB7251《低压成套开关设备和控制设备》IEC60439《低压开关设备和控制设备组件》所有标准均会被修改,供货方在设备设计和制造中所涉及的各项规程、协议和标准必须遵循现行最新版本的中国国家标准和行业标准。

2.2环境条件a)本条的目的在于强调设备应遵照的环境条件要求,因为这会影响设备的寿命、结构和运行可靠性。

b)下列环境条件适用按合同提供的所有设备和结构,特别是对于控制和仪表及电气设备的设计和选择尤其重要。

c)供货方必须保证提供的所有材料、设备、精加工件、装置和系统在运输、卸货、搬运、储存、安装和运行中能经得起环境的条件,并且没有损坏和失灵,能长期满容量连续运行。

d)环境条件见下表1周围空气温度最高温度℃40最低温度℃-10最大日温差K25日照强度W/cm2(风速0.5m/s)0.12海拔高度m2000(高原型)3最大风速m/s29.66离地面高10m处,30年一遇10min平均最大风速4环境相对湿度(在25℃时)平均值80%5地震烈度(中国12级度标准)8水平加速度g0.3垂直加速度g0.15地震波为正弦波,持续时间三个周波,安全系数1.676污秽等级III泄漏比距≥2.5cm/kV最高运行电压条件下,制造厂根据实际使用高海拔进行修正,并提供高海拔修正值7覆冰厚度(风速不大于15m/s时)10mm三、低压配电柜技术条件3.1低压抽出式开关柜:GCS型。

GCS型低压配电柜

GCS型低压配电柜

GCS 型抽出式(固定分隔式)开关柜1.概述GCS抽出式开关柜适用于发电厂、变电站、石油化工,厂矿企业、饭店及高层建筑等低压配电系统的动力、配电和电动机控制中心,电容补偿等的电能转换、分配与控制用。

在大单机容量的发电厂、大规模石化等行业的低压动力控制中心和电动机控制中心等电力使用场合时能满足与计算机接口的特殊需要。

GCS开关柜是根据电力部主管上级、广大电力用户及设计部门的要求,为满足不断发展的电力市场对增容、计算机接口,动力集中控制、方便安装维修、缩短事故处理时间等需要,本着安全、经济、合理、可靠原则设计的新型低压抽出式开关柜可以作为低压抽出式开关柜的换代产品使用。

GCS开关柜具有分断、接通能力高,动稳定性好,电气方案灵活,组合方便,系列性、实用性强,结构新颖,防护等级高等特点。

符合以下标准IEC60439.1-1999《低压成套开关设备和控制设备》GB7251.1-2005《低压成套开关设备和控制设备第1部分:型式试验和部分型式试验成套设备》JB/T 9661-1999《低压抽出式成套开关设备》等标准.2.产品型号与含义3.使用条件a)周围空气温度不高于40℃,不低于–5℃。

24小时内平均温度不得高于35℃超过时,需根据实际情况降容运行。

b)户内使用,使用地点的海拔不得超过2000m。

c)周围空气相对湿度,在最高温度为40℃时不超过50%,在较低温度时允许有较大的相对湿度,如20℃时为90%,应考虑到由于温度的变化可能会偶然产生凝露的影响。

d)开关柜安装时与垂直面的倾斜度不超过5%,且整组柜列相对平整(符合GBJ232-82标准)。

e)开关柜应安装在无剧烈震动和冲击以及不足以使电器元件受到不应有腐蚀的场所f)用户有特殊要求时,可以与制造厂协商解决。

4.电气性能:a)基本电气参数额定绝缘电压交流660(1000)V额定工作电压主电路交流380(600)V辅助电路交流380、220V直流220、110V额定频率50(60)HZ水平母线额定电流≤3150A垂直母线额定电流1000A额定峰值耐受电流(0.1S)105、176KA额定短时耐受电流(1S)50、80KAb)开关柜的主电路方案:共32组118个规格,额定工作电流为4000A,适合2500KVA及以下的配电变压器选用。

机房建设工程价格报价配置清单表

机房建设工程价格报价配置清单表

LED-203 70℃报警
莱安
¥680.00 个
3
¥2,040.00
60 烟雾探测器
LED-206保护范围约 30㎡/个 莱安
¥670.00 个
5
¥3,350.00
61 壁挂式红外探测器
62 吸顶式红外探测器
63 线材 A、 设备材料合计 B、 工程施工费 C、 税金 D、 工程总报价 机房 工程总
莱安
¥480,000.00 台
1
¥480,000.00
53 铜管、冷媒等
莱安
¥4,000.00 套
1
¥4,000.00
54 UPS
30KVA 1h
莱安
¥180,000.00 套
1
¥180,000.00
七、 机房监控
55 彩色半球摄像机
420线 SONY芯片 0.1LUX
莱安
¥1,800.00 个
8
¥14,400.00
¥1,346,608.51
15 地弹簧
16 钢制甲级防火门
17 踏步台阶
二、 配电系统工程
18 市电配电柜
机房建设工程价格报价配置清单表
规格
品牌
单价
单位 数量
金额
备注
600×600 25×25×5mm 600×600
Φ50
高100mm 1220×2440×3mm 12mm厚 12mm厚 重型 1500×2100mm
配梅兰日兰开关
¥75.00 ¥10,400.00
42 接地汇流排
莱安
¥650.00 组
1
¥650.00
43 接地黄绿线
BVV-6mm2
莱安

低压配电柜 材料清单 配置清单

低压配电柜 材料清单 配置清单

12
合计
14
应急照明配电箱 12AT
1
柜体
2
多功能电力仪表
3
隔离开关
4
互感器
5 双电源自动转换开关
6
断路器
7
交流接触器
8
浪涌保护器
9
多联开关控制器
10
辅材
11
人工费
12
合计
MNS-E/S PMAC720 5A YCF1-125/4P122 BH-0.66-50/5 WTS 63X/40A DPNN 16A vigi+30mA C65H/1P 16A C65H/3P 50A CT-16A 3P ARD-80/4P
单位 数量 单价 总价 台1 只1 只2
4
断路器
5
辅材
6
人工费
7
合计
17
动力配电箱 2KAP
序号 1 2 3 4
元件名称 柜体
多功能电力仪表 互感器 断路器
5
浪涌保护器
6
辅材
7
人工费
8
合计
18
动力配电箱 2KAP-1
序号 1 2 3 4 5 6 7
元件名称 柜体
隔离开关 控制与保护开关
断路器 辅材 人工费 合计
多功能电力仪表 互感器 断路器
5
浪涌保护器
6
多联开关控制器
7
辅材
型号规格 MNS-E/G YCF1-1250/4P122 PMAC720 5A BH-0.66-1000/5 NS100N/3P 125A TM热磁脱扣器 NS250N/3P 200 NS400N/3P 250 NT0-150 ARD-150/4P
型号:MNS-E/S

最新家用配电箱选型与配置方法

最新家用配电箱选型与配置方法

家用配电箱选型与配置方法一般家用总开关用2P 40A、63A带漏电或不带漏电,1.5P左右挂壁空调用20A,3-5P柜机需要25-32A,10P左右的中央空调需要独立的2P 40A左右。

厨房,卫生间需要25A左右,插座16-20A,照明10A就可以。

总开关稍微大一点,因为夏天用电高峰期电压会很低,分路不能大,大了起不来保护作用。

方法1:总开关用2P不带漏电的,一般插座、厨房、卫生间的独立回路一定要带漏电,因为厨房、卫生间相对潮湿,电源插座是常用的,还是宝宝容易接触到的地方,相对容易发生漏电的危险。

照明、空调不需要带漏电,用DPN双进双出的断路器就可以。

这样的配置好处就是:万一哪一路有问题就跳那一路,不会影响别的【推荐】方法2:总开关用2P带漏电的,分路就用DPN【火线+零线】不需要带漏电。

缺点就是万一一路有问题,可能是总开关跳闸,(因为断路器的灵敏度没有带漏电的高),会整个房间没电。

相对箱子可以小一点。

断路器的几大功能:A、短路保护:火线和零线接触,瞬间电流很大,断路器跳闸。

B、过载保护:就是用电电流超过电器的额定电流,断路器跳闸。

·C、漏电保护(电漏电保护装置):就是当漏电电流超过30毫安时,漏电附件自动跳闸,保护人体安全的。

一建知识记忆口诀1、措施费、规费、企业管理费:二环夜临大水,支架已安稳(文),保定无(污)公害,公差使用保险金务工2、建设工程项目施工成本管理的任务和环节:预测-计划-控制-核算-分析-考核(预计控,算分考)3、施工成本控制的一般步骤是:比较-分析-预测-纠偏-检查(比分遇纠察)4、项目经理的管理权力:组织管理班子;调配并管理项目的人、机、物、资等生产要素;进行经济分配;选择作业队伍;指挥生产;代表企业法定代表人处理外部关系;受托签署有关合同。

(班配配队、指外签)5、质量手册作为企业质量管理系统的纲领性文件应具备:指令性、系统性、协调性、先进性、可行性、可检查性。

低压配电柜_材料清单_配置清单

低压配电柜_材料清单_配置清单

9 应急照明配电箱
序号 1
2AT
型号规格 MNS-E/S
型号:MNS-E/S
单位 数量 单价 总价 台 1
元件名称 柜体
2 3 4 5 6
多功能电力仪表 互感器 隔离开关 双电源自动转换开关 断路器
7 8 9 10 11 12
交流接触器 浪涌保护器 多联开关控制器 辅材 人工费 合计
PMAC720 5A BH-0.66-50/5 YCF1-125/4P122 WTS 63X/40A DPNN 16A vigi+30mA C65H/1P 16A C65H/3P 50A CT-16A 3P ARD-80/4P DL-Y16 DL-X16
序号 1 2 3 4 5
1KAP
型号:MNS-E/G
型号规格 单位 数量 单价 总价 MNS-E/G 台 1 PMAC720 5A 只 1 YCF1-125/4P122 只 2 BH-0.66-300/5 只 3 NS160N/3P 125A TM热磁脱扣器 只 1 NS160N/3P 100A TM热磁脱扣器 只 1 NS100N/3P 32A MX TM热磁脱扣器 只 1 C65H/3P 25A 只 1 DPNN 20A vigi+30mA 只 1 DPNN 16A 只 5 NT0-150 只 3 ARD-150/4P 只 1 批 1 个 1
1 照明配电箱
序号 1 2 3 4 5
1ZAL
型号规格 MNS-E/G YCF1-1250/4P122 PMAC720 5A BH-0.66-1000/5 NS100N/3P 125A TM热磁脱扣器 NS250N/3P 200 NS400N/3P 250 NT0-150 ARD-150/4P

GGD型配电柜设计

GGD型配电柜设计

毕业设计说明书(论文)作者:教学点:专业:题目: GGD型配电柜设计评阅者:(姓名) (专业技术职务)2012 年 4 月 18 日毕业设计说明书(论文)中文摘要随着工业技术的发展,配电柜技术越来越多用于低压供电系统应用,特别是机加工车间线路里面采用集中控制线路的原则更加需要配电柜。

低压配电柜的设计是否合理关系到整个生产线设备安全可靠的运行。

配电柜在机加工车间里起到分配电能,及控制设备电源的作用,配电柜的设计与制作首先考虑的是控制对象的负荷功率的大小,根据负荷的大小才能正确地选用低压电器。

考虑到车间负荷较大采用两种配电柜,一种是电源柜,另一种是动力柜,电源柜起到分配电源的作用,动力柜起到控制设备电源作用,根据实际需要,这次毕业设计要设计GGD 型配电柜,我们的设计思路是安全,可靠、经济、美观、维修方便。

本次设计对GGD型配电柜设计有参考价值。

关键词:配电、负荷计算、低压计算的选择。

毕业设计说明书(论文)外文摘要Title machine shopABSTRACTWith the development of industrial technology, in the low-voltage power distribution equipment power supply system to enable more and more, especially in machine shop lines the inside line with the principle of centralized control is more necessary power distribution equipment. Whether the design of low voltage distribution cabinet reasonable relationship to the whole production line equipment safe and reliable operation. Distribution cabinet to play in the machine shop in the distribution of electric energy, the role of power and control equipment, power distribution equipment in the design and production of the first consideration is to control the size of the object load power, according to the size of the load can be properly selected low-voltage electrical. Taking into account the larger plant load distribution using two cabinets, one is the power supply cabinet, the other is the power cabinets, power distribution cabinet to play the role of power, dynamic power control equipment to play the role of cabinet, the Graduation to design GGD supply cabinet , our design idea is safe, reliable, economic, aesthetic, and easy maintenance.Keywords: distribution, load calculation, low voltage calculation choic本科毕业论文设计说明书(论文)第I页共I页目次第一章引言绪论 (1)1.1GGD型配电柜的背景 (1)1.2GGD型配电柜方案、设计相关知识 (2)1.3GGD型配电柜的研究目标、内容 (5)1.4GGD型配电柜的技术指标应用范围 (6)第二章 GGD型低压配电柜设计 (7)2.1GGD型低压配电柜总体设计 (7)2.2GGD型配电柜遇到的问题 (7)2.3设计系统达到的功能 (11)第三章 GGD型配电柜硬件设计 (13)3.1低压电器的选择 (13)3.2壳体设计 (18)3.3安全防护措施 (19)3.4壳体制作 (21)3.5电器元件装配 (23)第四章 GGD型配电柜软件设计 (25)4.1电缆与电线的选择与计算 (25)4.2一次加工、装配工艺 (28)4.3二次线装配 (26)第五章 GGD型配电柜常见故障判断及处理 (32)5.1元件故障及其查找 (32)第六章 GGD型低压配电柜的总结发展 (33)6.1GGD型低压配电柜的发展 (33)6.2GGD型低压配电柜的总结 (34)致谢 (35)参考文献及资料 (36)附录 (37)第一章引言绪论1.1 GGD型配电柜的背景低压配电柜广泛应用于工农业生产的方方面面,其结构简单,操作灵活。

一级配电箱配置图

一级配电箱配置图

河南豫德机电设备有限公司供货清单型号:临时电源总柜 2台序号元件名称型号及规格单位数量单价金额备注1 隔离开关HR3-630A 只 1 450 450 德力西2 电表DT862-1.5(6)A 只 1 200 200 德力西3 断路器DZ20-630/3300 630A 只 1 800 800 德力西透明4 漏电断路器DZ20LE-400/4300 400A 只 4 800 3200 德力西透明5 漏电断路器DZ20LE-250/4300 250A 只 2 360 720 德力西透明6 漏电断路器DZ15LE-2P 400A 只 2 60 120 德力西透明7 漏电断路器DZ47LE-2P 只 2 30 60 德力西透明8 插座AC-三插只 2 10 20 德力西9 互感器630/5 只 3 30 90 德力西10 电压表 A.V 只 4 30 120 德力西11 万转只 1 50 5012 配电柜(户外)2000*800*400 台 1 120013 安装台 1 40014 附料台 1 60015 单台合计台 1 803016 合计台 2 8030 16060总报价:壹万陆仟零陆拾元整(16060.00)河南豫德机电设备有限公司2016年3月1日河南豫德机电设备有限公司供货清单型号:临时电源总柜 2台序号元件名称型号及规格单位数量单价金额备注1 隔离开关HR3-630A 只 1 450 450 德力西2 电表DT862-1.5(6)A 只 1 200 200 德力西3 漏电断路器DZ20LE-630/4300 630A 只 1 1450 1450 德力西4 断路器DZ20-400/3300 400A 只 4 500 2000 德力西透明5 断路器DZ20-250 250A 只 2 260 520 德力西透明6 漏电断路器DZ15LE-2P 400A 只 2 60 120 德力西透明7 漏电断路器DZ47LE-2P 只 2 30 60 德力西透明8 插座AC-三插只 2 10 20 德力西9 互感器630/5 只 3 30 90 德力西10 电压表 A.V 只 4 30 120 德力西11 万转只 1 50 5012 配电柜(户外)2000*800*400 台 1 120013 安装台 1 40014 附料台 1 60015 单台合计台 1 728016 合计台 2 7280 14560总报价:壹万肆仟伍佰陆拾元整(14560.00)河南豫德机电设备有限公司2016年3月1日总箱:长:700 宽:300 高:1600(实际尺寸根据安装需要确定)要求:电箱内要设置照明和一处插座,板材采用热镀锌喷塑板材,厚度大于等于2mm,箱门上需安装电压表,以及电源指示。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
1
GCK
小计
综合取费

总合计

序号
名称
编号
单位
数量
单价
金额
备注
6
电容柜
GCK AN13、18

2
序号
名称
规格/型号
单位
数量
单价
金额
备注
熔断式隔离开关
HH15(QSA)-630A/3 0

1
电流互感器
BH-0.66ⅡΦ60 400/5 0.5S

3
电流表
42L6-A 2000/5

3
电压表
42L6-V
名称
规格/型号
单位
数量
单价
金额
备注
塑壳断路器
NM1-630S/3300 500A

1
塑壳断路器
NM1-125S/3300 100A

2
塑壳断路器
NM1-400S/3300 250A

2
电流互感器
LMZJ1 600/5 0.5S

3
电流互感器
LMZJ1 100/5 0.5S

6
电流互感器
LMZJ1 250/5 0.5S
序号
名称
规格/型号
单位
数量
单价
金额
备注
塑壳断路器
NM1-630S/3300 500A

2
塑壳断路器
NM1-125S/3300 80A

2
电流互感器
LMZJ1 600/5 0.5S

6
电流互感器
LMZJ1 100/5 0.5S

6
电流表
PA666-4S

4
电压表
PZ666-4S

4
熔断器
RT14-20 R 1~10A

1
功率因数表
42L6-COSɕ380V

1
电容补偿控制器
NWK

1
交流接触器
CJ19-43A/21

12
霹雷器
FSY2-0.22

3
熔断器
RT36-00-160 40A(R)

12
氮气电容器
BZMJ-YN0.4-16-3

12
熔断器
RT14-20 R 1~10A

8
转换开关
LW15-163/8

1

5
信号灯
AD11-22/20

3
铜排
水平母线:3{2(100*10)}+1(100*8)+1(50*5)
垂直母线:3(80*6)+1(60*6)+1(50*5)
kg
辅料

1
壳体
800*2200*1000

1
GCK
小计
综合取费

总合计

序号
名称
编号
单位
数量
单价
金额
备注
10
馈线柜
GCK AN20

1
序号

6
电压表
42L6-V

2
电能表
DT862 3(6)A

1
熔断器
RT14-20 R 1~10A

6
塑壳断路器
NM1-125S/4300 50A

1
浪涌保护器
NU6-11 4P 40KA

1
信号灯
AD11-22/20

2
按钮
LAY3-11

3
铜排
水平母线:3(125*10)+1(80*8)+1(40*5)
名称
规格/型号
单位
数量
单价
金额
备注
塑壳断路器
NM1-630S/3300 500A

2
塑壳断路器
NM1-125S/3300 40A

3
电流互感器
LMZJ1 600/5 0.5S

6
电流互感器
LMZJ1 50/5 0.5S

9
电流表
PA666-4S

5
电压表
PZ666-4S

5
熔断器
RT14-20 R 1~10A
名称
规格/型号
单位
数量
单价
金额
备注
抽屉式断路器
NA1-2000-1600M/3P

1
电流互感器
LMZJ1-0.5 2000/5 10VA 0.2级

4
电流表
42L6-A 2000/5

3
电压表
42L6-V

1
电能表
DT862 3(6)A

1
熔断器
RT14-20 R 1~10A

3
信号灯
AD11-22/20

8
电压表
PZ666-4S

8
熔断器
RT14-20 R 1~10A

8
信号灯
AD11-22/20

3
铜排
水平母线:3(125*10)+1(80*8)+1(40*5)
垂直母线:3(80*6)+1(60*6)+1(40*5)
kg
辅料

1
壳体
800*2200*1000

1
GCK
小计
综合取费

总合计

序号
名称
单位
数量
单价
金额
备注
5
电源进线柜GCK AN12、17台2序号名称
规格/型号
单位
数量
单价
金额
备注
抽屉式断路器
NA1-2000-2000M/3P

1
电流互感器
LMZJ1-0.5 2500/5 10VA 0.2级

4
电流表
42L6-A 2500/5

3
电压表
42L6-V

1
电能表
DT862 3(6)A

RT14-20 R 1~10A

6
信号灯
AD11-22/20

3
铜排
水平母线:3(125*10)+1(80*8)+1(40*5)
垂直母线:3(80*6)+1(60*6)+1(40*5)
编号
单位
数量
单价
金额
备注
14
双电源进线柜
GCK ANS1

1
序号
名称
规格/型号
单位
数量
单价
金额
备注
抽屉式断路器
NA1-2000-1600M/4P

1
抽屉式断路器
NA1-2000-1000M/4P

1
控制器
双电源控制器

1
电流互感器
LMZJ1-0.5 2000/5 10VA 0.2级

8
电流表
42L6-A 2000/5

2
按钮
LAY3-11

2
铜排
水平母线:3{2(100*10)}+1(100*8)+1(50*5)
垂直母线:3(80*6)+1(60*6)+1(50*5)
kg
辅料

1
壳体
800*2200*1000

1
GCK
小计
综合取费

总合计

序号
名称
编号
单位
数量
单价
金额
备注
9
馈线柜
GCK AN19

1
图号03
序号

6
电流表
PA666-4S

5
电压表
PZ666-4S

5
熔断器
RT14-20 R 1~10A

5
信号灯
AD11-22/20

3
铜排
水平母线:3{2(100*10)}+1(100*8)+1(50*5)
垂直母线:3(80*6)+1(60*6)+1(50*5)
kg
辅料

1
壳体
800*2200*1000

1

1
功率因数表
42L6-COSɕ380V

1
电容补偿控制器
NMK

1
交流接触器
CJ19-43A/21

15
霹雷器
FSY2-0.22

3
熔断器
RT36-00-160 40A(R)

15
氮气电容器
BZMJ-YN0.4-16-3

15
熔断器
RT14-20 R 1~10A

8
转换开关
LW15-163/8

1

1
塑壳断路器
NM1-125M/3300 63A

1
塑壳断路器
NM1-125M/3300 50A

1
塑壳断路器
NM1-125M/3300 40A
相关文档