格力中央网关说明书
基于CAN和Modbus的多联空调网关自动测试系统设计

基于CAN和Modbus的多联空调网关自动测试系统设计Design of Automatic Test System for Multi connected Air Conditioning Gateway Based on CAN and ModbusZhang Ze’e(GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI,Guangdong Zhuhai 519070)摘要:本文设计了一种基于CAN和Modbus RTU协议的多联空调网关功能自动测试系统,系统实现了网关提供的所有开放协议位的自动测试,上位机软件采用LabVIEW编程实现。
本文所介绍方案可为其他搭载多通讯协议的电子产品的自动测试系统设计提供参考。
关键词:CAN; Modbus; 多联空调; 网关; 自动测试;LabVIEW中图分类号:TP273 文献标识码:A文章编号:Abstract: This paper designs an automatic test system for the functions of the multi connected air conditioning gateway based on CAN and Modbus RTU protocols. The system realizes the automatic test ofall open protocol bits provided by the gateway. The upper computer software is programmed by LabVIEW. The scheme introduced in this paper can provide reference for the design of automatic test system of other electronic products equipped with multiple communication protocols.Key words: CAN; Modbus; Multi connected air conditioner; Gateway; Automated testing;LabVIEWCLC number: TP273 Document code:A Article ID:1.背景1.1Modbus协议介绍Modbus协议是施耐德电气于1979年开发的一种消息传递结构,用于在智能设备之间建立客户端-服务器通信。
最新格力空调主机面板操作说明教学教材

显示板控制面板1.电源指示灯(绿色), 显示板电源接通时该指示灯亮;否则时灭。
2.运行指示灯(绿色), 显示板开机是该指示灯亮;否则灭。
3.故障指示灯(红色), 机组故障时该指示灯亮,否则灭。
4.开/关键, 控制机组开关机切换。
关机状态下按一下(3秒)开机,开机状态下按一下(3秒)关机。
电源 运行 XXXX-XX-XX XX:XX 单冷模块机【热泵 4 5 615.复位键,按此键(3秒),屏幕满屏显示,故障显示清除,系统重新检测故障。
6.向上选择键,在菜单选择中,按此键光标向上或向左移动一项;在修改数据下,按此键增加数值。
7.向下选择键,在菜单选择中,按此键光标向下或向右移动一项;在修改数据下,按此键减小数值。
8.退出键, 按下此健,返回上级菜单。
9.确定键,在菜单选择中,按此键确认选择项,进入下级菜单;在修改参数下,按此键确认参数值并转移光标。
10.液晶显示器,信息显示区域。
显示板操作说明1. 机组的开/关非调试状态下机组的开关机,可以通过手动模式,也可通过定时模式。
手动模式优先于定时模式。
在调试状态下,手动和定时模式均无效。
●手动模式:1)、手动开机:在机组关机状态下,按开/关键3秒使机组启动,此时机组运行指示灯亮,压缩机延时启动后,手动开机过程结束;2)、手动关机:在机组开机状态下,按开/关键 3秒使机组关闭,此时运行指示灯熄灭。
停机后,压缩机立即停机,水泵会延时5分钟关闭。
手动关机过程结束。
●定时模式:机组上电或复位后,按手动模式进行开关机。
手动模式和定时模式的转换详见3.13启停模式设定。
在定时模式下手动和定时模式同时有效,当时间到达所设定的定时时间时,机组自动开启或关闭。
2. 默认主页菜单当控制器上电后,微电脑将做3秒钟的自动检测,显示板液晶显示器将显示如下:默认主页菜单内容随系统状态的变化而变化。
XX代表年月日小时和分钟,“【】”内的内容只显示其中的一个或不显示,分别表示系统的开关机状态、开机方式和联网模块数。
中央空调集控有线接口协议(MODBUS) V1.2说明书

协议文档版本发布时间备注V1.02020.09.29前建立文件V1.12020.03.05增加风向、自动风速的控制和查询;增加主从机的查询;增加空调性能信息的查询V1.22020.03.30增加清爽、自动除湿、贴心睡眠三种模式MODBUS-RTU通讯协议应用说明表1网关通讯参数设置项目参数传输模式半双工波特率9600bps起始位1位数据位8位校验位偶校验(Even)停止位1位以上通讯规格参数也可以通过网关自带的WEB页面进行变更表2主要应用的功能码网关所用功能码作用0x03(读保存寄存器)用于读取空调的状态。
每次可读操作一个或多个寄存器(寄存器地址必须连续)。
每个寄存器保存一个空调的一个状态参数,根据寄存器读取的数量,可以一次读取一个空调的一个或多个参数(如开关、温度设定等),也可以将若干空调的全部参数一次读出。
0x06(写单个寄存器)用于写设定一个空调的一个参数每次只能写操作一个寄存器,每写操作一次,就会对一个空调的一个参数做出设定指令。
0x10(写多个寄存器)用于写设定多个空调的多个参数每次可写操作多个寄存器(寄存器地址必须连续)。
根据写寄存器的数量,可以一次写设定一个空调的一个参数或多个参数,也可以一次写多个空调的多个参数。
状态参数,包括:开关状态、温度设定值、模式设定状态、风速设定、房间温度和故障代码、是否为主机。
空调性能参数,包括:空调品牌、模式信息风速信息、设定温度信息、特殊性能信息表3状态保存寄存器地址与空调室内机地址的对应关系空调室内机地址状态参数保存寄存器地址0-00,1,2,3,4,50-16,7,8,9,10,110-212,13,14,15,16,17…………0-31186,187,188,189,190,1911-0192,193,194,195,196,1971-1198,199,200,201,202,2031-2204,205,206,207,208,209…………1-31378,379,380,381,382,383…………空调性能信息8000,8001,8002,8003,8004室内机状态参数保存寄存器起始地址为4000,每4个连续地址的寄存器保存1个室内机的控制指令,包括:开关指令、温度设定值指令、模式设定指令、风速设定指令、风向设定指令;表4控制指令寄存器地址与空调室内机地址的对应关系如下表空调室内机地址控制指令寄存器地址0-04000,4001,4002,40030-14004,4005,4006,40070-24008,4009,4010,4011…………0-314124,4125,4126,41271-04128,4129,4130,41311-14132,4133,4134,41351-24136,4137,4138,4139…………1-314252,4253,4254,4255…………表5查询空调状态所用的点位表(对应MODBUS功能码0x03)空调地址AA-BB 外部查询访问时的寄存器地址B15---B8B7B6B5B4B3B2B1B000-00D00000000000故障:1正常:0运行:1停止:0 D00010设定温度D00020设定模式0000制热送风除湿制冷D0003风向设定设定风速00000低速中速高速D0004B15-B9B8房间回风温度是否为主机D00050故障代码00-01D0006当前启停状态:0x01->开机;0x00->关机。
格力 1.5匹 变频中央空调 使用安装说明书

使用安装说明书中静压风管送风式空调器使用前请仔细阅读本说明书,并妥善保管更多使用指引,请扫描“扫码开启服务”二维码目录声明●本产品执行标准:GB/T 18836。
●本说明书仅作示例说明,产品及部件外观请以实物为准。
● 使用前请仔细阅读本说明书及电子说明书,否则可能会给本机造成损害或危及您或他人的人身 财产安全。
由于技术更新,致产品升级或变更,恕不另行通知。
电子说明书也会随技术创新进 行更新,请扫描二维码获取最新电子说明书。
● 阅读后请与发票一起妥善保管。
安全警示空调器主体构件配件清单遥控器使用说明清洁保养安装及维修注意事项环保清单安装简图室内机回风箱进风面板室内机排水管的安装技术参数检验运行使用条件常见现象及故障安装服务、售后服务保修卡安全警示产品简介使用说明清洁保养安装说明服务指南01030304050708131416171919192021封底查阅电子说明书方法● 请扫描说明书封底“扫码开启服务”二维码。
安全警示01提示本节记载了安全事项的重要内容,以防止对使用者及他人造成人身伤害或财产损失。
请在充分理解下面内容(标志、图标)的基础上阅读正文,并请务必遵守所记载的安全事项。
禁止用电源开关直接关闭空调器。
请勿用湿手操作空调器。
禁止用水直接冲淋空调器。
卸下或打开面板时,切勿触碰空调器的金属部位。
不得让身体长时间直接接触冷风或制冷过度。
不得踩踏在室内机、室外机上,或在其上放置物品,避免遮挡进、出风口。
切勿用于食品、精密仪器、贵重美术品的保存,切勿安装在船舶、车辆等特殊场所。
切勿在空调风直接吹到的地方使用燃烧器具,在密闭的房间内使用或与燃烧器具同时使用时,请经常打开窗户通风。
切勿在室内机下面放置其它电气产品、家具、贵重物品等。
禁止擅自更换电源线,或将电源线中途驳接,或与其它电器并联使用;如果电源软线损坏,为了避免危险,必须由制造商、其维修部或类似部门的专业人员更换。
表示【禁止】的内容禁止在空调器使用场所存放易燃易爆气体;不得使用与空调器本身所配制冷剂不同的其它制冷剂。
小燕ac01室内机空调网关用户手册说明书

联系我们在线客服:https://www.xiaoyan.io/service 服务电话:400-920-2823电子邮件:******************上海小燕科技有限公司上海市浦东新区盛夏路666号E 幢502室1. 2.小燕室内机空调网关使用 ZigBee 无线通信协议,支持控制空调模式、温度、风速,实现智能控温、智能场景、绑定联动等功能。
产品介绍安装前请先将室内机断电,请勿带电操作。
打开空调内机检修口,将室内机网关置于吊顶上,注意安放位置远离内机,避免空调结露滴到网关上。
空调机网关不需供电,将室内机网关连接到内机线控端子处,各品牌连接方法如下表:将网关 P1/P2 连接线控端子 P1 P2不分正负将网关 P1/P2 连接线控端子 A B 不分正负将网关 P1/P2 连接线控端子 U3 U4 或A B 不分正负将网关 P1/P2 连接线控端子 X Y 不分正负安装说明-接线方式接线拨码完成后,给内机上电,网关开始自行搜索空调,搜索完毕后网关状态灯 STAT 由闪烁变为常亮,设备进入正常工作状态。
指示灯说明如果不保留原厂面板,请跳过此步骤。
原厂线控和室内机网关默认都作为主线控使用,如果要保留原厂线控,需将原厂线控或者室内机网关其中之一改为从线控才可避免冲突。
设置完成后需要给内机重新上电才能生效。
将室内机网关改为从线控方法:安装说明-与原厂面板共存温控面板使用(参考接线图1)需要将室内机网关的485的 AB 线连接到温控面板的485AB 线,建议面板单独供电,如需使用网关供电,此时网关的 VOUT+ VOUT- 可作为输出使用,最大向外输出 12V/40mA 。
空调线控端子(AIRCON P1 P2)用于第三方面板连接的485总线(485 A B )如果需要可以向面板供电 (VOUT + -)原厂线控可不接或按需配置安装说明-第三方温控面板将原厂面板改为从线控方法:安装说明-与原厂面板共存12345678大金日立东芝无无无无2根线2根线2根线2根线支持支持支持支持品牌接线方法接线极性接线数量原厂面板共存三菱重工将内机显示板的五芯线控延长线剪断 然后按照线序连接网关将三菱电机风管机专用接插件插到内机板上的 CN105 处将大金风管机专用接插件插到内机板上的S21 处将日立风管机专用接插件插到内机板上的CN2(线控器红)处将格力风管机专用接插件插到内机板 CN5(红色)处将网关 P1/P2 连接线控端子 P1 P2不分正负有有有有有无熄灭闪烁常亮未上电---供电正常4根线4根线4根线4根线4根线2根线支持支持不支持不支持不支持支持品牌接线方法接线极性接线数量原厂面板共存日立风管格力风管大金新风大金风管三菱电机美的C, E, H 系列原厂线控通过背面拨码开关进行设置,拨到从F 系列原厂线控通过长按取消按键进入菜单设置,选择主从设置,设置为从3Q 6Q 9Q 等面板直接并联,自动识别亲自无需设置8Q 面板不支持亲子共用,必须将原厂面板去掉86小面积背面拨码1拨到 0N 为从将网关 P1/P2 连接线控端子 P1 P2 不分正负翻盖面板通过背面 SW1 设置 拨到从菱耀室内机网关并未连接到线控上,与线控互不影响接触面板上电会提示是否使用之前设置,选择否,然后会再次提示选择为从品牌设置方法三菱重工三菱电机东芝日立大金将原厂面板改为从线控方法:安装说明-与原厂面板共存美的线控为单向传输,没有反馈,可以共用但不能同步不支持共用,必须将原厂面板去掉不支持共用,必须将原厂面板去掉不支持共用,必须将原厂面板去掉威能线控为单向传输,没有反馈,可以共用但不能同步品牌指示灯配网指示灯状态电源指示灯PWR网关状态灯STAT空调运转灯RUN空调模式灯MODE设置方法格力风管日立风管大金风管美的威能第三方显示面板线控网关室内机原厂线控器11234324搜索空调中设备异常空调关闭空调故障搜索完成空调开启红色制热模式蓝色制冷模式红蓝除湿模式正在连接附近的家庭中心送风模式---快速闪(每秒闪10下)连接家庭中心成功慢速闪(每2秒闪1下)连接家庭中心失败中速闪(每秒闪4下)官方微信恢复出厂设置参数规格质 保 卡1.2.3.4.启动小燕在家 APP, 登录进入;点击进入“添加设备”页面;接通网关电源,指示灯闪烁;约10秒后 APP 上显示找到新设备。
TESLARIA分布式中央空调机组网关EMC-AC-D说明书

1、网关接通DC12V 电源,首先显示本网关的设备ID 二维码,根据此码,可以对本网关进行远程固件升级或产品信息查看,如图:2、经过10秒钟后,网关进入初始化状态,如图:3、初始化状态大概持续20秒,后进入“可触发复位状态”,此时LCD 显示:“此时可长按SET 5秒复位”,如果不需要复位操作可等待20秒后自动跳过,如果需要进入复位状态,在显示“此时可长按SET5秒复位”时,按下“SET”持续5s 左右直到LCD 显示“复位中...”后松开按键,等待直到LCD 显示“复位成功”即完成复位,此时可直接进入WEB 页面配置,配置完成或复位恢复默认设置重新上电即可重新使用。
液晶屏显示按键说明TESLARIA分布式中央空调机组网关EMC-AC-D©2018 teslaria Company Limited这个符号表示本设备附带的说明书中具有重要的操作和维护说明。
重要安全说明• 必须保留这些注意事项。
• 必须注意所有警告内容。
• 必须遵循所有注意事项。
• 不要在靠近水的地方使用本设备。
• 只能用干布擦拭设备。
• 不要堵塞任何通风口。
遵循制造商的说明进行安装。
• 不要将本设备安装在任何热源附近,如散热器、调温器、火炉或其它可能产生热量的装置。
•必须由合资格电工,按相关电气标准进行安装操作;产品的运行调试须由经过系统培训的专业人员,按照指定规则说明的进行。
•在模块使用前,请确认控制电源电压是否符合要求,使用不符合电压要求的控制电源,可能会引起模块工作异常,甚至损坏模块。
•在负载接入前,请确认负载功率或负载性质与模块的技术参数要求是否相符,负载线径与负载功率是否匹配,以免损坏模块或发生安全问题。
•接线前必须断开所有通道电源以及总线电源,严禁带电操作。
• 保护电源线防止被脚踩踏或被夹紧,尤其是在插头、方便插座和机身电源线引出处。
• 只能使用制造商指定的连接件 / 附件。
• 只能使用制造商指定的或随设备售出的手推车、支座、三角架、托架或支撑台。
格力双系统户式中央空调安装使用说明书

目录一、系统介绍 -------------------------------------------------------------------- 2二、机组介绍 -------------------------------------------------------------------- 31.机组性能 ---------------------------------------------------------------------------------------- 3 2.机组外形示意图 ------------------------------------------------------------------------------- 4三、控制器操作说明 ----------------------------------------------------------- 6A.手操器显示功能------------------------------------------------------------------------------- 6 B.手操器按键功能 ----------------------------------------------------------------------------- 7 C.蜂鸣器------------------------------------------------------------------------------------------- 7 D.基本操作---------------------------------------------------------------------------------------- 7 E.故障代码表 ------------------------------------------------------------------------------------- 8四、日常操作与维护 ----------------------------------------------------------- 8五、常见故障及解决方法------------------------------------------------------ 9六、末端设备选型指导------------------------------------------------------- 10七、系统安装 ------------------------------------------------------------------ 101.机组安装 -------------------------------------------------------------------------------------- 10 2.机组接线 -------------------------------------------------------------------------------------- 12 3.末端设备安装 -------------------------------------------------------------------------------- 13 4.水管路连接 ----------------------------------------------------------------------------------- 13 5.冬季防冻注意事项 -------------------------------------------------------------------------- 14八、系统调试 ------------------------------------------------------------------ 151.空调系统冷冻水的充注 -------------------------------------------------------------------- 15 2.试运转前的检查 ----------------------------------------------------------------------------- 15 3.试运行 ----------------------------------------------------------------------------------------- 15九、随机附件使用说明------------------------------------------------------- 16尊敬的用户:欢迎您选用格力双系统户式(别墅)中央空调机组。
家用中 央空调使用说明

家用中央空调使用说明一、安装与调试在使用家用中央空调之前,首先要确保其安装和调试工作已经完成。
安装工作应由专业的安装人员进行,包括室内机和室外机的安装、管道连接、电气布线等。
安装完成后,需要进行调试,以确保系统运行正常。
调试时,需要检查空调的制冷、制热效果、风速、温度控制等功能是否正常。
同时,要检查空调系统是否有漏氟、漏水等问题。
如果发现问题,应及时联系安装人员进行处理。
二、开机与关机1、开机找到空调遥控器,确保电池电量充足。
按下遥控器上的“电源”按钮,启动空调。
选择运行模式,如制冷、制热、除湿、通风等。
一般来说,夏季选择制冷模式,冬季选择制热模式,潮湿的季节选择除湿模式,需要换气时选择通风模式。
设置温度。
根据您的需求,通过遥控器上的“温度+”和“温度”按钮来调整室内温度。
制冷时,建议温度设置在 25℃ 27℃之间;制热时,建议温度设置在 18℃ 22℃之间。
调整风速。
可以选择自动风速、低风速、中风速、高风速等不同的风速档位。
如果需要定时开机或关机,可以通过遥控器上的“定时”功能进行设置。
2、关机按下遥控器上的“电源”按钮,关闭空调。
如果长时间不使用空调,建议拔掉电源插头,以节省能源并确保安全。
三、温度调节合理的温度设置不仅能提高舒适度,还能节省能源。
在制冷模式下,温度设置过低不仅会增加耗电量,还可能导致室内外温差过大,引起身体不适。
在制热模式下,温度设置过高也会造成能源浪费,并使室内空气过于干燥。
此外,不同的房间和使用场景可能需要不同的温度设置。
例如,卧室的温度可以设置得稍高一些,以保证良好的睡眠环境;客厅等活动频繁的区域,温度可以根据个人感受进行适当调整。
四、风速调节风速的调节可以影响室内空气的循环速度和制冷、制热效果。
在刚开机时,可以选择高风速,以快速达到设定温度。
当室内温度接近设定温度时,可以将风速调整为低风速或自动风速,以保持舒适的室内环境。
如果房间较大,可以适当提高风速,以使室内空气均匀分布;如果房间较小,可以选择较低的风速,避免吹风感过强。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
2
中央空调 Modbus 网关套件用户说明书
3.1.4 DI/DO 数字量输入 / 输出
本网关目前支持 5 个 DI(数字输入),5 个 DO(数字输出),DO 6 预留。 DI1...DI5 数字输入 0/1 数字信号(二进制),适用无源输入。 DI 1:火警信号,短接 K1,则 DI 1 口输入火警信号“1”,Modbus 网关下发控制令所有空 调机组立即停止运行;断开 K1,则 DI 1 口输入信号“0”,恢复所有空调机组运行。 DI2...DI5:供用户自行定义 使用举例:将 K5 闭合,则读取 Modbus 协议中线圈 DI 5 位置,数值为“1”; 将 K5 断开,则读取 Modbus 协议中线圈 DI 5 位置,数值为“0”。
带匹配 电阻
不带匹配 电阻 功能
是拨钮的位置。
3.3.5 功能拨码器第 6 位——网关起始内机工程编号设置
参照“4.3 网络拓扑图”,CAN2 网络中,每台内机有其唯一能够区别于其它内机的身份标识,这个标识 称为内机工程编号。则同一 CAN2 网络中的内机的工程编号各不相同。 网关起始内机工程编号表示该网关可以处理的内机的范围。功能拨码器第 6 位拨码用于网关起始内机工 程编号设置。 内机的工程编号范围值为 1 ~ 255。 网关起始内机工程编号为 1:该网关可以处理工程编号为 1 ~ 128 的内机。 网关起始内机工程编号为 129:该网关可以处理工程编号为 129 ~ 255 的内机。 当内机的工程编号不在网关可处理范围,需改变内机的工程编号。 网关起始内机工程编号拨码设置示意图:
中央空调 Modbus 网关套件用户说明书
适用型号:MC30-24/E4(M)
珠 海 格 力 电 器 股 份 有 限 公 司
为了正确使用本产品,请在使用前仔细阅读本说明书,并妥善保存以供今后参考。 为使产品更好的适应客户而改进创新, 我公司保留修改内容而不事先通知的权利。 本说明书最终解释权归珠海格力电器股份有限公司所有。
DO数字量输出
电源输入
3.1.2 电源
电源输入为 100VAC-240VAC,50/60Hz。 警告:网关上电时,请勿触摸其电源输入处。
3.1.3 通讯接口
CAN 通讯接口:通过两芯通讯线连接至空调机组,实现 Modbus 网关与空调机组之间的通讯。 RS485-1 通讯接口: 通过两芯通讯线连接至格力远程监控 /BMS 端,实现 Modbus 网关与远程监控 /BMS 端的通讯连接或相邻 Modbus 网关的连接。 RS485-2 通讯接口:本装置暂不使用此通讯接口。
5 产品安装������������������������������������������������������������������9
5.1 产品尺寸及电控柜安装空间尺寸 ��������������������������������������������������� 9 5.2 通讯连接 ����������������������������������������������������������������������� 9
电源
3
中央空调 Modbus 网关套件用户说明书 3.2 LED 显示
CAN
RX TX RX TX RX TX RX TX 电源 运行 报警
当接收到 Modbus 网关连接的设备(如空调机组)的数据时,闪烁。 当传输数据至 Modbus 网关连接的设备(如空调机组)时,闪烁。 当接收到远程监控 PC 机或 BMS 端设备的数据时,闪烁。 当传输数据至远程监控 PC 机或 BMS 端设备时,闪烁。 本装置不使用此 LED 显示。 本装置不使用此 LED 显示。 本装置不使用此 LED 显示。 本装置不使用此 LED 显示。 当 Modbus 网关供电正常时,常亮。 当 Modbus 网关正常运行时,闪烁。 本装置不使用此 LED 显示。
功能拨码器第 7 位拨钮用于本网关在 485 总线(本网关所处的 485 总线在网络中体现为 Modbus 总线) 中匹配电阻的设置。 在 485 总线中,需要进行总线端接,即终端节点带匹配电阻,以避免传输线上发生信号反射。 Modbus 网关在应用中,通常已有上位机作为终端节点带 485 匹配电阻,则该位拨码默认出厂设置,不 带匹配电阻。 当需要 Modbus 网关作为 485 总线中带匹配电阻的节点时,则将该位拨码拨为带匹配电阻,并将 Modbus 网关连接在 485 总线终端。
中央空调 Modbus 网关套件用户说明书
1 功能概述
格力中央空调 Modbus 网关起着连接空调机组内部网络(CANbus)和监控网络 (Modbus) 的作用,提供格 力远程监控系统 /BMS 通讯接口 , 实现格力远程监控系统 /BMS 对机组状态的实时监测及远程控制。提供标 准 Modbus RTU 协议,并且提供十个 I/O 口(五个数字量输入,五个数字量输出),其中 DI1 已固定为火警 信号输入(当有火警信号输入时,Modbus 网关令所有空调机组立即停止运行)。 该网关适用的格力中央空调机型:GMV 5 直流变频多联空调机组、GMV 5S 全直流变频多联空调机组、水 源热泵直流变频多联机组。
C-1 制冷系统的调试 ���������������������������������������������������������������� 20 C-2 Modbus 网关与空调机组的通讯调试����������������������������������������������� 20 C-3 Modbus 网关拨码设置����������������������������������������������������������� 21 C-4 Modbus 网关与格力远程监控系统的通讯调试������������������������������系统1 主控机 设置为带 匹配电阻
外机系统2 主控机 设置为不带 匹配电阻
外机系统16 主控机 设置为不带 匹配电阻 设置为带 匹配电阻
匹配电阻拨码设置示意图:
带匹配 电阻
不带匹配 电阻 功能
是拨钮的位置。
5
中央空调 Modbus 网关套件用户说明书
3.3.4 功能拨码器第 7 位——485 总线匹配电阻设置
3.1 接口 ��������������������������������������������������������������������������� 2 3.2 LED 显示����������������������������������������������������������������������� 4 3.3 拨码 ��������������������������������������������������������������������������� 4
2 组成部件
本套件包含如下部件。请在安装前进行检查。
Modbus 网关 安装说明书 1套 1份
1
中央空调 Modbus 网关套件用户说明书
3 Modbus 网关详细介绍
3.1 接口
3.1.1 接口示意图
CAN通讯接口, 与空调机组通讯 DI数字量输入
RS485-1通讯接口,与 远程监控/BMS端通讯
功能拨码器第 8 位拨钮用于本网关在 CAN2 总线中匹配电阻的设置。 当 Modbus 网关在 CAN2 总线上处于首 / 尾端时, 需设置网关为带匹配电阻, 则将功能拨码器第 8 位拨钮拨为 0。 当 Modbus 网关在 CAN2 总线上不是首 / 尾端时,设置网关为不带匹配电阻,将该位拨码拨为 1。
RS485-1
RS232
RS485-2
3.3 拨码
注意!在使用本装置前,请先对其进行拨码设置,否则将不能正常工作! Modbus 网关拨码设置区域由地址拨码器和功能拨码器组成。
3.3.1 拨码器示意图
该位拨码 值为0 0 1 1 2 3 4 5 6 7 8 该位拨码 值为1
低位 是拨钮的位置。
高位
4
火警信号
K5
K4
K3
K2
K1
DO1...DO5 数字输出 继电器输出,常开触点 最大可容纳电量:250VAC,3A 30VDC,3A 使用举例:向 Modbus 协议中线圈 DO 5 位置写入数值“1”,则 DO 5 继电器的两个触点闭合; 向 Modbus 协议中线圈 DO 5 位置写入数值“0”,则 DO 5 继电器的两个触点断开。
4 使用场合������������������������������������������������������������������7
4.1 格力中央空调远程监控系统 ������������������������������������������������������� 7 4.2 楼宇管理系统 (BMS)������������������������������������������������������������� 7 4.3 网络拓扑图 ��������������������������������������������������������������������� 7
中央空调 Modbus 网关套件用户说明书
3.3.2 地址拨码器——MODBUS 网关设备地址设置
地址拨码器用于设置 Modbus 网关的设备地址。 注意! 在使用本网关前,需先对网关的地址拨码器进行设置,且同一条现场总线网络拨码地址不能重复,否则 将通讯故障。 Modbus 网关设置地址范围值:1 ~ 255。具体拨码值参见拨码地址附表。 地址设置举例: 地址 11 的设置方法如下图所示:
用户须知