外包式埋入式钢柱柱脚计算(高钢规)

合集下载

“外柱柱脚”节点计算书

“外柱柱脚”节点计算书

“外柱柱脚”节点计算书一.节点基本资料设计依据:《钢结构连接节点设计手册》(第二版)节点类型为:圆柱埋入刚接柱截面:φ299×12,材料:Q355柱与底板全截面采用对接焊缝,焊缝等级为:二级,采用引弧板;底板尺寸:1×B=700mm×700mm,厚:T=30mm锚栓信息:个数:4采用锚栓:双螺母弯钩锚栓库_Q345-M24方形锚栓垫板尺寸(mm):B×T=70×20底板下混凝土采用C30基础梁混凝土采用C30埋入深度:1.2m栓钉生产标准:GB/T10433栓钉抗拉强度设计值:f=215N∕mm2栓钉强屈比:γ=1.67沿Y向栓钉采用:M19×100行向排列:12OmmX9列向排列:45o×2沿X向栓钉采用:M19×100行向排列:120mm×9列向排列:45o×2实配用冈筋:4HRB400C20+10HRB400C20÷10HRB400C20近似取X向钢筋保护层厚度:Cx=30mm近似取Y向钢筋保护层厚度:Cy=30mm节点示意图如下:二.荷载信息设计内力:组合工况内力设计值工况N(kN)Vx(kN)Vy(kN)Mx(kN∙n Q)My(kN∙m)组合工况-813.227261.830.0 0.0 5.219三.验算结果一览验算项数值限值结果最大压应力(MPa) 1.39最大14.3满足等强全截面1满足基底最大剪力(kN)219最大273满足绕X轴抗弯承载力(kNXm)1311 最小1019满足绕y轴抗弯承载力(kN×m)1873 最小1019满足沿Y向抗剪应力比 5.29最大71.3满足沿X向抗剪应力比O最大71.3满足X向栓钉直径(mm)19.0最小16.0满足X向列间距(mm)117最大200满足X向列间距(mm)76.0最大200满足X向行间距(mm)120最大200满足X向行间距(mm)120最小114满足X向边距(mm)149最小为29.5满足Y向栓钉直径(mm)19.0最小16.0满足Y向列间距(mm)117最大200满足Y向列间距(mm)76.0最大200满足Y向行间距(mm)120最大200满足Y向行间距(mm)120最小114满足Y向边距(mm)149最小为29.5满足绕Y轴承载力比值0.65最大1.00满足绕X轴承载力比值0最大1.00满足绕Y轴含钢率(%) 0.65最小0.20满足绕X轴含钢率(%) 0.65最小0.20满足沿Y向主筋中距(mm)83.3 最小45.0 满足沿Y向主筋中距(mm)83.3最大200满足沿X向主筋中距(mm)83.3最小45.0满足沿X向主筋中距(mm)83.3最大200满足沿Y向锚固长度(mm)920最小700满足沿X向锚固长度(mm)920最小700满足四.混凝土承载力验算控制工况:组合工况1N=(-813.227)kN;底板面积:A=1×B=700×700×10-2=4900cm2底板承受的压力为:N=813.227kN底板下混凝土压应力:σc=813.227/4900×10=1.6596N∕mm2<14.3,满足五.柱对接焊缝验算柱截面与底板采用全对接焊缝,强度满足要求六.柱脚抗剪验算控制工况:组合工况1N=(-813.227)kN;Vx=261.83kN;Vy=OkN;锚栓所承受的总拉力为:Ta=OkN柱脚底板的摩擦力:Vfb=O.4X(-N+Ta)=0.4x(813.227+0)=325.29kN柱脚所承受的剪力:V=(Vx2+Vy2)0.5=(219.322+02)0.5=219.32kN<325.29,满足七.柱脚节点抗震验算1绕X轴抗弯最大承载力验算绕X轴柱全塑性受弯承载力:Wp=3953712mm3Mp=WpXfy=3953712×235=929.12232kN∙m因为N∕Ny=813227/2542616.6=0.268742837>0.2,所以Mpc=1.25(1-N/Ny)Mp=849.284kN∙m绕X轴柱脚的极限受弯承载力:Mu,basej=fckBc1[((21+hb)2+hb2)0.5-(21+hb)]=20.1×209.3×4000×[((2×4000+1200)2+12002)0.5-(2×4000+1200)]=1311.398kN∙m>=1.2Mpc=1.2×8.492842e+008=1019.141kN∙m,满足2绕y轴抗弯最大承载力验算绕y轴柱全塑性受弯承载力:WP=3953712mm3Mp=Wp×fy=3953712×235=929.12232kN∙m因为N∕Ny=813227/2542616.6=0.268742837>0.2,所以Mpc=1.25(1-N∕Ny)Mp=849.284kN∙m绕y轴柱脚的极限受弯承载力:Mu,basej=fckBc11((21+hb)2+hb2)0.5-(21+hb)]=20.1×299×4000×[((2×4000+1200)2+12002)0.5-(2×4000+1200)]=1873.425 kN∙m>=1.2Mpc=1.2×8.492842e+008=1019.141kN∙m,满足八.栓钉验算栓钉生产标准:GB/T10433栓钉抗拉强度设计值:f=215N∕mm2栓钉强屈比:γ=1.67沿Y向栓钉采用:M19×100行向排列:120mm×9列向排列:45o×2沿X向栓钉采用:M19×100行向排列:12OmmX9列向排列:45o×21沿Y向栓钉验算承载力验算控制工况:组合工况1控制内力:N=(-813.227)kN,My=5.219kN∙m,Vx=261.83kN顶部箍筋处弯矩设计值:Myu=∣16.37+0.21932×50∣=27.336kN∙mX向截面高度:hx=299mmX向翼缘厚度:tx=12mm沿Y向一侧栓钉承担的翼缘轴力:Nf=27.336∕(299-12)×103=95.247kN单个栓钉受剪承载力设计值计算:栓钉钉杆面积:As=πd2∕4=3.142×192/4=283.529mm2Nvs1=0.43×As(Ec×fc)0.5=0.43×283.529×(429000)0.5×10-3=79.854kNNvs2=0.7×As×f×γ=0.7×283.529×215×1.67×10-3=71.261kNNvs=min(Nvs1,Nvs2)=71.261kN沿Y向栓钉抗剪等效列数:Nr=ZCOSa=2沿Y向单根栓钉承受剪力:V=95.25∕9∕2=5.292kN<71.26,满足2沿X向栓钉验算承载力验算控制工况:组合工况1控制内力:N=(-813.227)kN,Mx=OkNm,Vy=OkNY向顶部箍筋处弯矩设计值:Mxu=∣0-0×50∣=0kN∙mY向截面高度:hy=299mmY向翼缘厚度:ty=12mm沿X向一侧栓钉承担的翼缘轴力:Nfy=0∕(299-12)×103=0kN沿X向栓钉承受剪力为零,承载力满足要求九.钢筋验算1内力计算Y向承载力验算控制工况:组合工况1控制内力:My=5.219kN∙m,Vx=261.83kNY向柱脚底部弯矩设计值:Myd=∣5.219+261.83×1.2∣=319.42kN∙m2承载力计算外包混凝土X向长度:X=580mm外包混凝土Y向长度:Y=580mm实配钢筋:4HRB400.20÷10HRB400_20+10HRB400_20单侧角筋面积:Ac=628,319mm2沿Y向中部筋面积:Amy=1570.796mm2外包混凝土X向计算长度:X0=580-30-20×0.5=540mm构造要求沿Y向配筋量:Aymin=0.002×XO×Y=626.4mm2沿Y向单侧实配面积:Asy=Ac+Amy=2199.115mm2≥Aymin=626.4,满足要求沿X向中部筋面积:Amx=1570.796mm2外包混凝土Y向计算长度:Y0=580-30-20×0.5=540mm构造要求沿X向配筋量:Axmin=0.002×YO×X=626.4mm2沿X向单侧实配面积:Asx=Ac+Amx=2199.115mm2>Axmin=626.4,满足要求沿Y向钢筋中心间距:X00=500mm角筋绕Y轴承载力:Mcy=Ac×Fyc×X0=628.319×360×540×10-6=122.145kN∙m 中部筋绕Y轴承载力:Mmy=Amx×Fym×XO=1570.796×360×540×10-6=305.363kN∙m实配钢筋绕绕Y轴承载力:MSy=MCy+Mmy=I22.145+305.363=427.508kN∙m Msy>∣My∣=319.42,满足要求沿X向钢筋中心间距:Y00=500mm角筋绕X轴承载力:Mcx=Ac×Fyc×Y0=628.319×360×540X10-6=122.145kN∙m 中部筋绕X轴承载力:Mmx=Amx×Fym×YO=1570.796×360×540×10-6=305.363kN∙m实配钢筋绕X轴承载力:Msx=Mcx+Mmx=122.145+305.363=427.508kN∙m Msx>∣Mx∣=0,满足要求“内柱柱脚”节点计算书一.设计依据本工程按照如下规范、规程、设计手册进行设计:1.《钢结构设计标准》(GB500I7-2017)2.《建筑结构荷载规范》(GB50009-2012)3.《建筑抗震设计规范》(GB500U-2010)(2016年版)4.《高层民用建筑钢结构技术规程》(JGJ99-2015)5.《钢结构连接节点设计手册》(第三版)李星荣魏才昂秦斌主编6.《钢结构设计方法》童根树著7.《混凝土结构设计规范》(GB50010-2010)(2015年版)二.计算软件信息本工程计算软件为钢结构软件PKPM-STSV5计算日期为2023年4月8日18时12分2秒计算书中未标注单位的数据,单位均为mm三,计算结果一览四.节点基本资料节点编号=44;柱截面尺寸:圆管299X16;材料:Q355;柱脚混凝土标号:C30;柱脚底板钢号:Q355;埋入深度:1.20叱柱脚底板尺寸:B×H×T=540X540X30;锚栓钢号:Q355;锚栓直径D=24;锚栓垫板尺寸:BXT=70X25;环向锚栓数量:4柱与底板采用对接焊缝连接;加劲肋与柱连接采用对接焊缝;埋入部分顶面加劲肋设置:T=16;栓钉直径:16;栓钉长度:65;单列侧栓钉数:4个;竖向受力筋强度等级:HRB(F)400;箍筋强度等级:HRB(F)335;保护层厚度:250;实配钢筋(埋入式柱脚已按极限承载力进行调整):横向单侧受力筋:3Φ22;横向单侧架立筋:2Φ16;竖向单侧受力筋:3Φ22;竖向单侧架立筋:2Φ16;顶部附加箍筋:3Φ12@50;一般箍筋:4>10@100;五.计算结果1.栓钉抗剪承载力校核说明:高钢规已取消,结果仅供参考;栓钉抗剪承载力内力设计值N=721199kN,V=0.429kN,M=0.789kN∙m栓钉直径:16;栓钉长度:65;单列侧栓钉数:4个;单个栓钉的抗剪承载力:N:=min(0.43AJEJ c0.7AYf)y O MU r VV=ιnin(0.43×201.06×y∣30000.00×14.30,0.7×201.06×167×235.00)=50.53kN合力弯矩作用力臂(相对X轴为):y1nax=105.7i各位置栓钉的力臂总和为:¾≡=4470050单个栓钉承受剪力为:MEV XymC1XNNF=-5⅛ ------------ +7=3776730.00×105.71/(2×44700.50)+758729.00/4=194.17kNN v =N p ∕n v =194169.0()/4=48.54kNNVVN 栓钉抗剪承载力满足要求!2 .侧面混凝土承压计算钢标算法: 计算配筋为:_My+/X ,_]328540().()()+13050.6()X897.0() AS =0.9f y b 0= 0.9X360.00X697构造配筋为:=0.87N∕mtn 2_________ / _________ 26548.80+(2×1001.53/897.00+I)2299X89700OCW0%=14.30N∕mm2,侧面混凝土承压验算满足要求!3.柱脚配筋校核(1)翼缘侧配筋计算: 高度方向拉延筋形心间距:h 0=697计算配筋为:心+… A109Wo构造配筋为:A min =0.002b 0h 0=0.002×697×697=97162mn?(2)腹板侧配筋计算: 宽度方向拉延筋形心间距: 23068200.00÷23154.70X897.000.9×360.00X697194.12mm 22×1(X)1.53 897.00+Du +A min=0.002h0h0=0.002×697×697=97162nιf n2(3)实配钢筋(埋入式柱脚已按极限承载力进行调整):横向单侧受力筋:3Φ22;横向单侧架立筋:2Φ16;竖向单侧受力筋:3Φ22;竖向单侧架立筋:2Φ16;顶部附加箍筋:3Φ12@50;一般箍筋:<M0@100;4.柱脚极限承载力验算结果连接系数:∏j=1.20柱脚最大轴力和轴向屈服承载力的比值0.10圆管柱:N∕N v W0.2圆管柱截面全塑性受弯承载力:W p=1282.79cm3MP=W p×f y=1282790.00×345.00=442.56kN・m取M nr=Mn=442.56kN∙m圆管柱脚连接的极限受弯承载力:M U=SJH⑵+〃/+幼2.⑵÷hβ)∣20.IO×299×12(X).00×{y∣(2×1200.00+897.00)2+897.0()2-(2×12(X).(X)+897.00)}864.29kN∙mM11>Q i M nr=531.07kN-m,满足要求!u J∕7c“裙房柱脚”节点计算书一.设计依据本工程按照如下规范、规程、设计手册进行设计:1.《钢结构设计标准》(GB50017-2017)2.《建筑结构荷载规范》(GB50009-2012)3.《建筑抗震设计规范》(GB50011-2010)(2016年版)4.《高层民用建筑钢结构技术规程》(JGJ99-2015)5.《钢结构连接节点设计手册》(第三版)李星荣魏才昂秦斌主编6.《钢结构设计方法》童根树著7.《混凝土结构设计规范》(GB50010-2010)(2015年版)二.计算软件信息本工程计算软件为钢结构软件PKPM-STSV5计算日期为2023年4月8日18时3分23秒计算书中未标注单位的数据,单位均为mm三.计算结果一览柱截面尺寸:圆管299X12;材料:Q355;柱脚混凝土标号:C30:柱脚底板钢号:Q355;埋入深度:1.20m;柱脚底板尺寸:BXHXT=540×540X30;锚栓钢号:Q355:锚栓直径D=24;锚栓垫板尺寸:BXT=70X14;环向锚栓数量:4柱与底板采用对接焊缝连接:加劲肋与柱连接采用对接焊缝;埋入部分顶面加劲肋设置:T=13:栓钉直径:16;栓钉长度:65;单列侧栓钉数:4个;竖向受力筋强度等级:HRB(F)400:箍筋强度等级:HRB(F)335;保护层厚度:250;实配钢筋(埋入式柱脚已按极限承载力进行调整):横向单侧受力筋:3Φ22;横向单侧架立筋:2Φ16;竖向单侧受力筋:3Φ22;竖向单侧架立筋:2Φ16;顶部附加箍筋:3Φ12Θ50;一般箍筋:<MO@100;五.计算结果1栓钉抗剪承载力校核说明:高钢规已取消,结果仅供参考;栓钉抗剪承载力内力设计值:N=351.958kN,V=11.028kN,M=20.194kN∙m栓钉直径:16;栓钉长度:65;单列侧栓钉数:4个:单个栓钉的抗剪承载力:N:=min(0.43A sγ∣E c f cc,0.7A sγf)=min(0.43×201.()6Xyj25500.0()×9.60,0.7×201.06×167×235.00)=42.78kN合力弯矩作用力臂(相对X 轴为):y f nax=105.71各位置栓钉的力臂总和为:⅛n=4470050单个栓钉承受剪力为:NF=A +^=/7900900.00×105.71/(2×44700.50)+337571.00/4=130.45kN Z ysum4 N v =Nm=130450.00/4=32.61kNNVVN 栓钉抗剪承载力满足要求!2 .侧面混凝土承压计算钢标算法:/ 22510.47 +(2×1730.32∕897.00+I)2299X897.00=1.06N∕mm 2OC^0.8f c =9.60Λ½ww 2,侧面混凝土承压验算满足要求! 3 .柱脚配筋校核(1)翼缘侧配筋计算:高度方向拉延筋形心间距:(2h(∕d+1)2/,o σc=(~T+DU+2×1730.32897.00+Du+计算配筋为: 22310600.00+9788.28X897KX) 0.9X360.00X697 构造配筋为: A min =0.002h 0h 0=0.002×697×697=97162nιf n 2(2)腹板侧配筋计算:计算配筋对应的内力组合号:1(非地震组合);内力设计值:M v =-34.59kN ・m ;V r =-20.34kN;宽度方向拉延筋形心间距:%=697计算配筋为:_MV+½y X>_34593200.00+20341.50X897.0()A S =0.9fyb 0 = 0.9×360.00X697构造配筋为:A min =0.002b 0h 0=0.002X697×697=971.62mm 2(3)实配钢筋(埋入式柱脚已按极限承载力进行调整):横向单侧受力筋:3Φ22;横向单侧架立筋:2Φ16;竖向单侧受力筋:3Φ22;竖向单侧架立筋:2616;顶部附加箍筋:3Φ12@50;一般箍筋:4>10@100;4 .柱脚极限承载力验算结果连接系数:∏j =1.20柱脚最大轴力和轴向屈服承载力的比值:0.09圆管柱:N∕N v W0.2yM r +V v Xh A s =0.9f y h 0137.67mιn^=233.98nun^圆管柱截面全塑性受弯承载力:W p=989.00cm3MP=W p×f y=989004.00X345.00=341.21kN∙in取M nr=M n=341.21kN∙m圆管柱脚连接的极限受弯承载力:MM=f*"∖∕⑵+hB)2+a2-(21÷hβ))=13.40×299X3400.00×(y∣(2×3400.00+897,00)2+897.002-(2×3400.00+897,00)) =709.61kN*mM1t>H i M nr=409.45kN・〃i,满足要求!。

钢结构外包式柱脚计算-外包式柱脚

钢结构外包式柱脚计算-外包式柱脚
外包式柱脚计算
柱底内力 M(kN•m) 1234.49 N(kN) 365.76 V(kN) 85.57 C30混凝土 Ec(N/mm2) fc(N/mm2) 30000 14.3 h(mm) 800
柱截面尺寸h﹡b﹡tw﹡t
b(mm) 600
tw(mm) 16
t(mm) 36
M作用下钢柱一侧翼缘轴力Nf Nf=M/hc= 1615.825 (kN) 栓钉受剪承载力Ncv N v<0.43*A*√(Ec*fc) = 107.0613 (kN) Ncv<0.7*A*γ *f = 95.54065 (kN)
γ = 1.67 钢筋规格 HRB335
保护层厚度c(mm)= 40 保护层+纵筋+箍筋δ (mm)= 77 包脚有效高度h0(mm)
fy(N/mm2)= 300
纵筋直径 A1(mms 25
h0=h'-2*c= 1146
纵向钢筋计算面积As As > Mb/(fy*h0) > 4088.511 mm2 As > 0.2%*h'*b' > 2860 mm2
c
hc(mm) =h-t = 764 栓钉规格∅ 22
2 A(mm )= 380.1327
栓钉受拉设计值 f(N/mm2) 215 h'(mm) 1300
包脚尺寸h'﹡b'*H
b'(mm) 1100
H(mm) 2000
栓钉抗拉与屈服强度之比
栓钉数目n >Nf/Ncv= 16.91243 包脚底部弯矩Mb Mb=M+V*H= = 1405.63 (kN•m)
Vcs>Vb,箍筋满足
注:只有红色文字可以改动;灰色区域为结果输出

外包式钢柱脚设计方法研究及其在加建改造中的应用

外包式钢柱脚设计方法研究及其在加建改造中的应用

外包式钢柱脚设计方法研究及其在加建改造中的应用舒睿彬【摘要】目前国内规范对于外包式钢柱脚的设计计算原则、设计计算方法还存在矛盾和不足.依据强连接弱构件的基本抗震原理要求,采用二阶段设计原则,并利用混凝土结构、钢结构等构件承载力设计计算原理和方法,以及现有的试验结果,提出了一套较完整、合理、可行的外包式钢柱脚的设计计算方法及公式.以该设计方法和公式,在实际加建工程中设计应用,获得了较大的经济利益.同时,外包式钢柱脚的受力机理、钢柱偏置等等问题仍有待后续研究.【期刊名称】《结构工程师》【年(卷),期】2016(032)005【总页数】6页(P166-171)【关键词】外包式钢柱脚;加建改造;二阶段抗震设计原则;强连接弱构件【作者】舒睿彬【作者单位】华东建筑设计研究院有限公司,上海200002【正文语种】中文柱脚是上部结构与基础连接的重要部分,是决定其整个结构体系承载能力的一个重要因素,柱脚是否合理不仅关系到整个建筑的安全性,还对建筑结构的受力性能、施工及整个工程产生重大影响[1-2]。

柱脚形式有外露式柱脚、埋入式柱脚、外包式钢柱脚等。

外包式钢柱脚由于连接方便、施工简单,在加建改造项目中应用广泛。

外包式柱脚是由钢柱(表面设置抗剪栓钉)和相应高度的外包钢筋混凝土柱墩(厚度不小于180 mm,配置有纵向钢筋、箍筋)组成(图1)。

外包式钢柱脚受力机理复杂,现行文献[3-4]研究表明:钢柱与下部结构(或基础)铰接,柱底弯矩与剪力均由外包钢筋混凝土柱墩部分承担,柱底压力通过外包式混凝土柱墩部分和钢柱脚底板传给下部结构(或基础),柱底拉力主要通过外包式混凝土柱墩部分传给下部结构(或基础)。

现阶段国内规范外包式钢柱脚的设计计算方法存在矛盾和不足。

本文将依据强连接弱构件的基本抗震原理要求,采用二阶段设计原则,并利用混凝土结构、钢结构等构件承载力设计计算原理和方法,以及现有的试验结果,提出了一套较完整、合理、可行的外包式钢柱脚的设计计算方法及公式。

钢结构刚性固定钢柱脚设计方法的总结

钢结构刚性固定钢柱脚设计方法的总结

钢结构刚性固定钢柱脚设计方法的总结一、钢柱柱脚形式的分类刚性固定柱脚:1)埋入式柱脚;2)外包式柱脚;3)插入式柱脚;铰接柱脚:外露式柱脚;二、埋入式柱脚2.1、基本概念:所谓埋入式柱脚是指将钢柱底端直接埋入混凝土基础筏板、地基梁或地下室墙体内的一种刚性连接的柱脚。

其特点是埋入相对自身绝对刚性的基础中而形成刚性固定柱脚节点。

这种柱脚构造可靠,常用于高层钢结构框架柱的柱脚。

2.2、埋入式柱脚的受力特点(1)柱的轴向压力N,由钢柱的柱脚底板直接传递给钢筋混凝土基础;柱的轴向拉力,则是通过柱脚底板悬出部分将其上部混凝土的反向压力传递给基础,或经由锚栓(底脚螺栓)直接传给基础。

(2)柱的弯矩M有两种传递方式:a、均由H型钢柱翼缘上的抗剪圆柱头焊钉传递给基础,在实际工程设计中大多采用该方法。

(也有研究说:该形式的柱脚中栓钉的作用不大,内力的传递主要是下述方式。

)b、依靠钢筋混凝土对钢柱翼缘的侧向承压力所产生的抵抗拒来传递给基础。

(3)柱脚顶部的水平剪力V由钢柱翼缘与基础混凝土侧向承压力来传递。

由于目前还没有能力考虑的有利因素如下:(4)钢柱翼缘与基础混凝土在侧向承压应力状态下,由于钢柱翼缘与混凝土摩擦而产生的抵抗力,设计时不考虑。

(5)钢柱翼缘与基础混凝土之间的粘结作用设计时不考虑。

(6)在确定埋入钢柱周边对称配置的垂直纵向钢筋面积时,不考虑由钢柱承担的弯矩。

埋入式柱脚的埋深与构造示意图如下:2.3、埋入式柱脚一般构造要求及部分细部设计计算2.3.1、埋入式柱脚的钢柱埋入基础的深度一般可以在以下范围内采用(hc为钢柱截面的高度或管径):a、轻型工字钢截面柱:H=(2.0~2.5)hc;b、圆管形截面柱和箱型截面钢柱:H=(2.5~3.0)hc。

2.3.2、埋入式柱脚,在钢柱埋入部分的顶部,应设置水平加劲肋或横隔板;对H型截面柱,其水平加劲肋外伸宽度的宽厚比应不大于9(235/fay),对于箱型截面柱,其内部横隔板的宽厚比应不大于30(235/fay),2.3.3、埋入式柱脚在钢柱的埋入部分,应设置圆柱头抗剪栓钉,栓钉的数量和布置,应按计算要求确定。

外包式柱脚计算

外包式柱脚计算

γ = 1.67 钢筋规格 HRB335
保护层厚度c(mm)= 40 保护层+纵筋+箍筋δ (mm)= 77 包脚有效高度h0(mm)
fy(N/mm2)= 300
纵筋直径 A1(mm2) 箍筋直径 A2(mm2) 箍筋肢数nv 箍筋间距s 25
h0=h'-2*c= 846
490.8739 翼缘处混凝土有效宽度be=b'-b= 550 12 113.0973 6 100
Vcs>Vb,箍筋满足
注:只有红色文字可以改动;灰色区域为结果输出
c v
hc(mm) =h-t = 632 栓钉规格∅ 22 A(mm2)= 380.1327 栓钉受拉设计值 f(N/mm2) 215 h'(mm) 1000
包脚尺寸h'﹡b'*H
Ncv<0.43*A*√(Ec*fc) = 107.0613 (kN) N v<0.7*A*γ *f = 95.54065 (kN)
c
b'(mm) 1000
H(mm) 600
栓钉抗拉与屈服强度之比
栓钉数目n >Nf/Nc v = 5.134006 包脚底部弯矩Mb Mb=M+V*H= = 361.342 (kN•m) 纵向钢筋计算面积As As > Mb/(fy*h0) > 1423.727 mm2 As > 0.2%*h'*b' > 2000 mm2
外包式柱脚计算
柱底内力 M(kN•m) 310 N(kN) 400 V(kN) 85.57 C30混凝土 Ec(N/mm2) fc(N/mm2) 30000 14.3 h(mm) 650
柱截面尺寸h﹡b﹡tw﹡t

埋入式型钢混凝土柱脚计算

埋入式型钢混凝土柱脚计算

(4)
(5)
(6)
f上]] 耻蟛+华一半lk2 \b。。矗)3
当‰≤^。时(图4b)
N B=N d
(8)
%=屹 M|=rima
(10)
310
MB=M:城-hB一毕h:
式中:M。——柱脚型钢底板下的弯矩设计值 ⅣB——柱脚型钢底板下轴力设计值 %——柱脚型钢底板下剪力设计值
M!——底层柱下端截面组合的弯矩设计值;

型钢截面形
式及承压方



¨

be
[=============一

“1
2,。+2df
8I

il
aj
18

,。+2dr;
3,。+4dr
f。——腹板厚度; df——腹板外表面至腹板弧端距离; hF——柱脚埋入深度;
必——型钢的弯矩(必=肜一/),W“为对X轴的净截面塑性抵抗矩;
,。——混凝土轴心抗压强度设计值
玎——底层柱下端截面组合的弯矩设计值增大系数,根据《建筑抗震设计规范》(GB
的规定:一、二、三级框架结构的底层柱分别取1.5、1.25和1 15。
50011
2001)6.2

Jv。、必为柱脚型钢(型钢芯柱)在基础顶面处所承受的轴力、弯矩设计值
3底板下混凝土强度验算
在上述公式所确定的型钢混凝土柱底轴力Ⅳ口和弯矩MB的作用下,埋八式柱脚型钢底板下的混凝土应满
足下列公式要求: N日≤NB。
(12)MB。——型钢底板下混凝土部分的承载力设计值。计算时取型钢底板的混凝土截面.将型
钢底板的锚栓作为受拉钢筋,按钢筋混凝土截面计算其承载力。
4柱脚受剪承载力
对于型钢埋置深度较浅(AB≤h。)的埋八式柱脚(图4b),其型钢底板底面在水平剪力%作用下,应满足

(整理)柱脚计算结果

(整理)柱脚计算结果

柱脚计算一、GZ1柱脚计算(5-17轴):查得节点处的最不利内力组为:M=227.51KN ·MN=381.1KN柱底最大剪力为:V=64.34KN ,所对应的轴力为:N=175.6KN,则,柱底板与混凝土柱之间产生的磨擦力为F=0.4N=70.24KN>V=64.34KN,柱底抗剪满足!柱脚计算简图如附图二所示假定砼柱的强度等级为C20,则 fc=10N/mm 2按构造要求,底板尺寸取为:B ×L=310x900则底板所受的最反力为:2291.765.62632max min/10/28.763.09003101048.3046900310106.1756mm N f mm N BL M BL N c =<=±=⨯⨯⨯±⨯⨯=+=-σ经计算,砼柱抗压强度满足!如图所示,经计算,底板各区格所受的反力为:2221/67.4,/29.6mm N mm N ==σσ底板所受的最大弯矩为:1.对三边简支板:b 1=100,a 1=250b 1/a 1=0.40查得β2=0.04392221max 23/2170325091.70439.0mm N a M =⨯⨯==σβ2.对四边支承板b 1=250,a 1=100b 1/a 1=2.5查得α=0.1103222114/693810029.61103.0mm N a M =⨯⨯==ασ3.对四边支承板b 1=500,a 1=125b 1/a 1=4查得β2=0.12502221223/912112567.41250.0mm N a M =⨯⨯==σβ则:mm t mm f M t 25,213002170366max min ==⨯==取 靴梁计算:靴梁所承担的均布线荷载为:q=155×7.91=1226N/mm 2,则:Nql V mm N ql M 2452002001226/1052.24200122621212622=⨯==⨯=⨯⨯== 取-500x12x900,则:2222262/175/3.61500122452005.15.1/300/41500121052.2455mm N f mm N th V mm N f mm N th M V =<=⨯⨯===<=⨯⨯⨯==τσ 靴梁与柱底板采用双面角焊缝:mmh mm t h mmt h f f f 125.7255.15.14.14122.12.1max min min max ===≥=⨯=≤取施焊时不采用引弧板,则焊缝计算长度为:l W =200-10=190mm22/200/8.761902127.02452007.0mm N f mm N l h V w f w f =<=⨯⨯⨯==τ 靴梁与柱翼缘板采用h f =12mm 的单面角焊缝,其焊缝计算长度为:l W =500-10=490mm22/200/60490127.02452007.0mm N f mm N l h V w f w f =<=⨯⨯==τ 柱底板加劲肋计算:柱底板加劲肋所承担的均布线荷载为:q=6.29x100=629N/mm 2则:N ql V mm N ql M 786252506292121/1091.425062981812622=⨯⨯==⨯=⨯⨯== 取-250x10x500则:2222262/175/6.2350010786255.15.1/300/82.9500101091.455mm N f mm N th V mm N f mm N th M V =<=⨯⨯===<=⨯⨯⨯==τσ 底板加劲肋与底板连接时采用h f =8mm 的单面角焊缝,其计算长度为: l W =250-10=240mm22/200/5.5824087.0786257.0mm N f mm N l h V w f w f =<=⨯⨯==τ 底板加劲肋与靴梁连接时采用h f =6mm 的单面角焊缝,其计算长度为: l W =500-10=490mm22/200/2.3849067.0786257.0mm N f mm N l h V w f w f =<=⨯⨯==τ 锚栓计算:受压区计算长度:mm x 48965.691.791.7900=+⨯=底板形心到受压区合力线的距离为:mm a 28734892900=-= 锚栓轴线到受压区合力线的距离为:mm y 6373489100900=--= 则锚栓所受的最大拉力为: KN y Na M N t 399637287106.175105.30436=⨯⨯-⨯=-= 采用2M48-Q235钢锚栓,查得其单个锚栓所能承担的最大拉力为:[N t ]=206.2KN>N t =399/2=200KN锚栓支承加劲肋计算:每个锚栓支承加劲肋所承受的剪力为:V=400/4=100KN取-195x10x400 则:22/175/5.37400101000005.15.1mm N f mm N th V V =<=⨯⨯==τ 锚栓支承加劲肋与靴梁采用h f =6mm 的双面角焊缝连接,其计算长度为: l W =400-10=390mm 则:22222223222/200/4.486.30)22.18.45(/6.30239067.0101007.0/8.45239067.05.971000067.06mm N f mm N mm N l h V mm N l h Ve w f f f f w f f w f f =<=+=+⎪⎪⎭⎫ ⎝⎛=⨯⨯⨯⨯===⨯⨯⨯⨯⨯==τβστσ 锚栓支承加劲肋与顶板的连接采用h f =6mm 双面角焊缝,其计算长度为: l W =195-10=185mm 则:22/200/4.64218567.01000007.0mm N f mm N l h V w f w f =<=⨯⨯⨯==τ 锚栓支承垫板的计算:mm N Qa M ∙⨯=+⨯⨯==4105.152)556(22004141 采用-100x25x160则:22432/300/24452082.1105.152;520825)50100(61mm N f mm N W M mm W n n =<==⨯⨯===⨯-⨯=γσ经计算,柱脚安全二、GZ1柱脚计算(4轴):查得节点处的最不利内力组为:M=376.32KN ·MN=109.53KN柱底最大剪力为:V=64.34KN ,所对应的轴力为:N=175.6KN,则,柱底板与混凝土柱之间产生的磨擦力为F=0.4N=70.24KN>V=64.34KN,柱底抗剪满足!柱脚计算简图如附图三所示假定砼柱的强度等级为C20,则 fc=10N/mm 2 按构造要求,底板尺寸取为:B ×L=310x900则底板所受的最反力为:2238.960.82632max min/10/99.839.09003101032.37669003101053.1096mm N f mm N BL M BL N c =<=±=⨯⨯⨯±⨯⨯=+=-σ经计算,砼柱抗压强度满足!如图所示,经计算,底板各区格所受的反力为:2221/38.5,/38.7mm N mm N ==σσ底板所受的最大弯矩为:1.对三边简支板:b 1=100,a 1=250b 1/a 1=0.40查得β2=0.04392221max 23/2573625038.90439.0mm N a M =⨯⨯==σβ2.对四边支承板b 1=250,a 1=100b 1/a 1=2.5查得α=0.1103222114/814010038.71103.0mm N a M =⨯⨯==ασ3.对四边支承板b 1=500,a 1=125b 1/a 1=4查得β2=0.12502221223/1050812538.51250.0mm N a M =⨯⨯==σβ则:mm t mm f M t 25,233002573666max min ==⨯==取 靴梁计算:靴梁所承担的均布线荷载为:q=155×9.38=1454N/mm 2,则:Nql V mm N ql M 2908002001454/101.29200145421212622=⨯==⨯=⨯⨯== 取-500x12x900,则:2222262/175/7.72500122908005.15.1/300/4950012101.2955mm N f mm N th V mm N f mm N th M V =<=⨯⨯===<=⨯⨯⨯==τσ 靴梁与柱底板采用双面角焊缝:mmh mm t h mmt h f f f 125.7255.15.14.14122.12.1max min min max ===≥=⨯=≤取施焊时不采用引弧板,则焊缝计算长度为:l W =200-10=190mm22/200/1.911902127.02908007.0mm N f mm N l h V w f w f =<=⨯⨯⨯==τ 靴梁与柱翼缘板采用h f =12mm 的单面角焊缝,其焊缝计算长度为:l W =500-10=490mm22/200/71490127.02908007.0mm N f mm N l h V w f w f =<=⨯⨯==τ 柱底板加劲肋计算:柱底板加劲肋所承担的均布线荷载为:q=7.38x100=738N/mm 2 则:N ql V mm N ql M 922502507382121/1077.525073881812622=⨯⨯==⨯=⨯⨯== 取-250x10x500则:2222262/175/2850010922505.15.1/300/54.11500101077.555mm N f mm N th V mm N f mm N th M V =<=⨯⨯===<=⨯⨯⨯==τσ 底板加劲肋与底板连接时采用h f =8mm 的单面角焊缝,其计算长度为: l W =250-10=240mm22/200/6924087.0922507.0mm N f mm N l h V w f w f =<=⨯⨯==τ 底板加劲肋与靴梁连接时采用h f =6mm 的单面角焊缝,其计算长度为: l W =500-10=490mm22/200/4549067.0922507.0mm N f mm N l h V w f w f =<=⨯⨯==τ 锚栓计算:受压区计算长度:mm x 4706.838.938.9900=+⨯=底板形心到受压区合力线的距离为:mm a 29334702900=-= 锚栓轴线到受压区合力线的距离为:mm y 6433470100900=--= 则锚栓所受的最大拉力为: KN y Na M N t 5356432931053.1091032.37636=⨯⨯-⨯=-= 采用2M56-Q235钢锚栓,查得其单个锚栓所能承担的最大拉力为:[N t ]=284.2KN>N t =535/2=267.5KN锚栓支承加劲肋计算:每个锚栓支承加劲肋所承受的剪力为:V=535/4=134KN取-195x10x400 则:22/175/3.50400101340005.15.1mm N f mm N th V V =<=⨯⨯==τ 锚栓支承加劲肋与靴梁采用h f =6mm 的双面角焊缝连接,其计算长度为: l W =400-10=390mm 则:22222223222/200/6541)22.161(/41239067.0101347.0/61239067.05.9713400067.06mm N f mm N mm N l h V mm N l h Ve w f f f f w f f w f f =<=+=+⎪⎪⎭⎫ ⎝⎛=⨯⨯⨯⨯===⨯⨯⨯⨯⨯==τβστσ 锚栓支承加劲肋与顶板的连接采用h f =8mm 双面角焊缝,其计算长度为: l W =195-10=185mm 则:22/200/22.86218587.01340007.0mm N f mm N l h V w f w f =<=⨯⨯⨯==τ 锚栓支承垫板的计算:mm N Qa M ∙⨯=+⨯⨯==4105.224)562(22684141 采用-160x25x160则:22432/300/176106252.1105.224;1062525)58160(61mm N f mm N W M mm W n n =<==⨯⨯===⨯-⨯=γσ经计算,柱脚安全三、GZ2柱脚计算:查得节点处的最不利内力组为:M=340.63KN ·MN=594.54KN柱脚计算简图如附图四所示假定砼柱的强度等级为C20,则 fc=10N/mm 2按构造要求,底板尺寸取为:B ×L=360x1050则底板所受的最反力为:2272.658.32632max min/10/15.557.110503601063.34061050360105.5946mm N f mm N BL M BL N c =<=±=⨯⨯⨯±⨯⨯=+=-σ经计算,砼柱抗压强度满足!如图所示,经计算,底板各区格所受的反力为:2221/76.4,/74.5mm N mm N ==σσ底板所受的最大弯矩为:1.对三边简支板:b 1=100,a 1=300b 1/a 1=0.330查得β2=0.03552221max 23/4.2147030072.60355.0mm N a M =⨯⨯==σβ2.对四边支承板b 1=300,a 1=100b 1/a 1=3.0查得α=0.1189222114/682510074.51189.0mm N a M =⨯⨯==ασ3.对四边支承板b 1=650,a 1=150b 1/a 1=4.3查得β2=0.12502221223/1338815076.41250.0mm N a M =⨯⨯==σβ则:mm t mm f M t 25,213004.2147066max min ==⨯==取 靴梁计算:靴梁所承担的均布线荷载为:q=180×6.72=1210N/mm 2,则:Nql V mm N ql M 2420002001210/102.24200121021212622=⨯==⨯=⨯⨯== 取-500x12x1050,则:2222262/175/61500122420005.15.1/300/4050012102.2455mm N f mm N th V mm N f mm N th M V =<=⨯⨯===<=⨯⨯⨯==τσ 靴梁与柱底板采用双面角焊缝:mmh mm t h mmt h f f f 125.7255.15.14.14122.12.1max min min max ===≥=⨯=≤取施焊时不采用引弧板,则焊缝计算长度为:l W =200-10=190mm22/200/761902127.02420007.0mm N f mm N l h V w f w f =<=⨯⨯⨯==τ 靴梁与柱翼缘板采用h f =12mm 的单面角焊缝,其焊缝计算长度为:l W =500-10=490mm22/200/59490127.02420007.0mm N f mm N l h V w f w f =<=⨯⨯==τ 柱底板加劲肋计算:柱底板加劲肋所承担的均布线荷载为:q=5.74x100=574N/mm 2 则:N ql V mm N ql M 861003005742121/1046.630057481812622=⨯⨯==⨯=⨯⨯== 取-300x10x500则:2222262/175/83.2550010861005.15.1/300/92.12500101046.655mm N f mm N th V mm N f mm N th M V =<=⨯⨯===<=⨯⨯⨯==τσ 底板加劲肋与底板连接时采用h f =8mm 的单面角焊缝,其计算长度为: l W =300-10=290mm22/200/5329087.0861007.0mm N f mm N l h V w f w f =<=⨯⨯==τ 底板加劲肋与靴梁连接时采用h f =6mm 的单面角焊缝,其计算长度为: l W =500-10=490mm22/200/4249067.0861007.0mm N f mm N l h V w f w f =<=⨯⨯==τ 锚栓计算:受压区计算长度:mm x 68558.372.672.61050=+⨯=底板形心到受压区合力线的距离为:mm a 297368521050=-= 锚栓轴线到受压区合力线的距离为:mm y 72236851001050=--= 则锚栓所受的最大拉力为: KN y Na M N t 2277222971054.5941063.34036=⨯⨯-⨯=-= 采用2M42-Q235钢锚栓,查得其单个锚栓所能承担的最大拉力为:[N t ]=156.9KN>N t =227/2=114KN锚栓支承加劲肋计算:每个锚栓支承加劲肋所承受的剪力为:V=227/4=57KN取-190x10x400 则:22/175/2140010570005.15.1mm N f mm N th V V =<=⨯⨯==τ 锚栓支承加劲肋与靴梁采用h f =6mm 的双面角焊缝连接,其计算长度为: l W =400-10=390mm 则:22222223222/200/2717)22.125(/17239067.010577.0/25239067.0955700067.06mm N f mm N mm N l h V mm N l h Ve w f f f f w f f w f f =<=+=+⎪⎪⎭⎫ ⎝⎛=⨯⨯⨯⨯===⨯⨯⨯⨯⨯==τβστσ 锚栓支承加劲肋与顶板的连接采用h f =6mm 双面角焊缝,其计算长度为: l W =190-10=180mm 则:22/200/38218067.0570007.0mm N f mm N l h V w f w f =<=⨯⨯⨯==τ 锚栓支承垫板的计算:mm N Qa M ∙⨯=+⨯⨯==41023.81)552(21144141 采用-100x25x160则:22432/300/11658332.11023.81;583325)44100(61mm N f mm N W M mm W n n =<==⨯⨯===⨯-⨯=γσ经计算,柱脚安全三、GZ3,3a,4,4a 柱脚计算:查得节点处的最不利内力组为:M=539.34KN ·MN=800.2KN柱脚计算简图如附图五所示假定砼柱的强度等级为C20,则 fc=10N/mm 2 按构造要求,底板尺寸取为:B ×L=380x1050则底板所受的最反力为:2273.971.52632max min/10/72.701.210503801034.53961050380102.8006mm N f mm N BL M BL N c =<=±=⨯⨯⨯±⨯⨯=+=-σ经计算,砼柱抗压强度满足!如图所示,经计算,底板各区格所受的反力为: 2221/79.6,/26.8mm N mm N ==σσ底板所受的最大弯矩为:1.对三边简支板:b 1=100,a 1=320b 1/a 1=0.32查得β2=0.03062221max 23/3048832073.90306.0mm N a M =⨯⨯==σβ2.对四边支承板b 1=320,a 1=100b 1/a 1=3.2查得α=0.1201222114/992010026.81201.0mm N a M =⨯⨯==ασ3.对四边支承板b 1=650,a 1=160b 1/a 1=4.1查得β2=0.12502221223/2172816079.61250.0mm N a M =⨯⨯==σβ 则:mm t mm f M t 32,1.252903048866max min ==⨯==取 靴梁计算:靴梁所承担的均布线荷载为:q=190×9.73=1849N/mm 2,则:Nql V mm N ql M 3698002001849/1037200184921212622=⨯==⨯=⨯⨯== 取-500x12x1050,则:2222262/175/5.92500123698005.15.1/300/6250012103755mm N f mm N th V mm N f mm N th M V =<=⨯⨯===<=⨯⨯⨯==τσ 靴梁与柱底板采用双面角焊缝:mmh mm t h mmt h f f f 125.7255.15.14.14122.12.1max min min max ===≥=⨯=≤取施焊时不采用引弧板,则焊缝计算长度为:l W =200-10=190mm22/200/1161902127.03698007.0mm N f mm N l h V w f w f =<=⨯⨯⨯==τ 靴梁与柱翼缘板采用h f =12mm 的单面角焊缝,其焊缝计算长度为:l W =500-10=490mm22/200/90490127.03698007.0mm N f mm N l h V w f w f =<=⨯⨯==τ 柱底板加劲肋计算:柱底板加劲肋所承担的均布线荷载为:q=8.26x100=826N/mm 2 则:N ql V mm N ql M 1321603208262121/106.1032082681812622=⨯⨯==⨯=⨯⨯== 取-320x10x500则:2222262/175/40500101321605.15.1/300/2.2150010106.1055mm N f mm N th V mm N f mm N th M V =<=⨯⨯===<=⨯⨯⨯==τσ 底板加劲肋与底板连接时采用h f =8mm 的单面角焊缝,其计算长度为:l W =320-10=310mm22/200/7631087.01321607.0mm N f mm N l h V w f w f =<=⨯⨯==τ底板加劲肋与靴梁连接时采用h f =6mm 的单面角焊缝,其计算长度为: l W =500-10=490mm22/200/2.6449067.07.0mm N f mm N l h w f w f =<=⨯⨯==τ锚栓计算: 受压区计算长度:mm x 66271.573.973.91050=+⨯=底板形心到受压区合力线的距离为:mm a 304366221050=-= 锚栓轴线到受压区合力线的距离为:mm y 72936621001050=--= 则锚栓所受的最大拉力为:KN y Na M N t 406729304102.8001034.53936=⨯⨯-⨯=-= 采用2M52-Q235钢锚栓,查得其单个锚栓所能承担的最大拉力为:[N t ]=246.1KN>N t =406/2=203KN锚栓支承加劲肋计算:每个锚栓支承加劲肋所承受的剪力为:V=406/4=102KN取-188x10x400 则:22/175/38400101020005.15.1mm N f mm N th V V =<=⨯⨯==τ 锚栓支承加劲肋与靴梁采用h f =6mm 的双面角焊缝连接,其计算长度为: l W =400-10=390mm 则:22222223222/200/4831)22.145(/31239067.0101027.0/45239067.0941*******.06mm N f mm N mm N l h V mm N l h Ve w f f f f w f f w f f =<=+=+⎪⎪⎭⎫ ⎝⎛=⨯⨯⨯⨯===⨯⨯⨯⨯⨯==τβστσ锚栓支承加劲肋与顶板的连接采用h f =6mm 双面角焊缝,其计算长度为:l W =190-10=180mm 则:22/200/68217867.07.0mm N f mm N l h w f w f =<=⨯⨯⨯==τ锚栓支承垫板的计算:mm N Qa M ∙⨯=+⨯⨯==41033.157)557(22034141采用-100x32x160则:22432/295/16778512.11033.157;785132)54100(61mm N f mm N W M mm W n n =<==⨯⨯===⨯-⨯=γσ经计算,柱脚安全。

埋入式钢柱脚的传力分析和设计计算

埋入式钢柱脚的传力分析和设计计算

埋入式钢柱脚的传力分析和设计计算金 波(杭州广播电视大学 杭州 310012)童根树(浙江大学建筑工程学院 杭州 310027)摘 要:对埋入式钢柱脚的设计方法进行了研究,分析了其传力的机理。

指出因为栓钉的存在,钢柱必然传递一部分轴力给外包混凝土柱,利用组合柱理论对外包混凝土的压力进行了计算,得到了简单的公式,通过算例发现,传递到外包混凝土的轴力是总轴力的25%~35%。

根据这个传递比例,提出栓钉验算和柱脚底板计算的方法。

同时,根据混凝土埋入式钢柱脚的弯矩和剪力的传递,介绍了混凝土埋入式钢柱脚抗弯强度的计算公式,对于边柱和角柱,提出了沿整个埋入深度设置水平U 形钢筋的要求和计算方法。

对于竖向抗冲切不足的问题,介绍了设置水平短钢梁将竖向力扩散到更大范围的方法。

关键词:埋入式钢柱脚 荷载传递 抗剪强度 组合柱A STU DY ON DESIGN METHOD OF BURIED STEEL COLUMN BASESJin Bo(Hangzhou Radio and TV University Hangzhou 310012)Tong Genshu(School of Archi tecture &Engineering,Zhejian g Universi ty Hangzhou 310027)Abstract :A theoretical s tudy is carried out on the current design approach of embedded steel colu mn bases.The load transfer within embedded bases is analyzed.Because of the studs,part of the axial load is transferred from steel to foundation concrete.An analytical solution is presented for the ax ial load in the concrete.Through calculated examples it is found that the axial force i n the concrete is 25%~35%of the total axial force of the column.Based on this finding,the design methods of shear stud and the column base plate are proposed.Based on the shear and bending moment transfer of the embedded s teel column bases,the strength check is proposed,and for side columns and corner columns,horizontal U rebars are proposed to preven t horizontal punch shear failure of concrete,method for determining the area of the U rebars is presented.Embedded steel column bases have inadequate vertical punch shear strength below.It is presented a method for avoiding this punch shear failure by adding horizontal short steel beams at the base.Keywords :embedded steel column base load transfer shear strength composi te column第一作者:金 波 男 1972年10月出生 硕士 讲师 全国注册监理工程师E-mail:jb@收稿日期:2007-12-201 概 述埋入式钢柱脚即将钢柱埋入钢筋混凝土基础中,基础可以是基础梁、独立基础和片筏基础,其构造如图1所示,柱脚传递轴力、剪力和弯矩。