Toneluck微动开关 E43AN-AA13Ag-01 技术规格书
开关和指示器_eao-01系列

18
01.2000
Accessories附件 01
前面
灯罩
a
b
外形 灯罩/灯座 颜色
18 x 24 mm 型号
18 x 18 mm 型号
直型号径 1 8 m m e
灯罩
平面 透明/半透明
1 UT 01-701.006 01-703.006 01-741.006 3 2 1 1 0,008
Байду номын сангаас
2 UT 01-702.006 01-704.006 01-742.006 4 2 1 1 0,008
连接方式: ST = 焊接接头; PT = 快速连接接头; UT = 通用接头; PCB 插座见20页 标记见33页 尺寸图见27页,安装尺寸图和单元图见29页,电路图见31页
14
01.2000
Description 说明
01
一般资料
01 系列照明按钮配有快动或低电平开关单元。 对于 2.8mm 快速连接接头的开关单元,除了标准触点 (镀金的银)外, 还可供应银触点。 这些按钮的前框尺寸为 18x24mm,18x18mm 或直径 18mm。 除了这些照明按钮外,用户亦可从具有同一前框和安装尺寸的其他各类 按钮和附件中选择指示器。
红色 01-901.2 01-951.2 01-931.2 0,001
白色 01-901.9 01-951.9 01-931.9 0,001
黄色 01-901.4 01-951.4 01-931.4 0,001
塑料
平面 不透明/半透明 黑色
1 main UT 01-713.029 01-717.029 01-747.029 11 5 1 1 0,010
mom UT 01-705.029 01-709.029 01-743.029 25 5 1 1 0,010
SENTRON 3VA1 三极模具保护电源断路器数据表说明书

6.22 in 158 mm 4.13 in 105 mm 2.76 in 70 mm
Front terminal
nut keeper kit on both ends 13 x 1 mm
25 x 8 mm
Silver
No Yes No No 0
Yes
3VA12204EF320AA0 3VA9688-0BL33
Environmental conditions protection class IP / on the front ambient temperature ● during operation / minimum ● during operation / maximum ● during storage / minimum ● during storage / maximum
3VA12204EF320KA0 Page 3/6
2/17/2022
Subject to change without notice © Copyright Siemens
-Q
135
last modified:
3VA12204EF320KA0 Page 4/6
I> I> I>
24
10/3/2021 2/17/2022
Data sheet
3VA1220-4EF32-0KA0
circuit breaker 3VA1 IEC frame 250 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=200A overload protection Ir=140A...200A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC
艾特顾问系列E71光电近距离感应开关说明书

Eaton 100528Eaton Moeller® series E71 Proximity switch, optical, long range 35cm, 4L, 10-30VDC, NPN, M8General specificationsEaton Moeller® series E71 Proximity switch100528E71-SDN-M84015081643349471.83 mm 9.91 mm 9.91 mm 0.09 kgCE UL 508 ULIEC/EN 60947-5-2CSA File No.: UL report applies to both US and Canada CSA-C22.2 No. 14 UL File No.: E166051Certified by UL for use in Canada UL Category Control No.: NRKH, NRKH7Product NameCatalog Number Model Code EANProduct Length/Depth Product Height Product Width Product Weight Certifications0 V1 ms0 mm1Status indication of Operating voltage: Green LED Status indication of Switching state: Yellow LEDOther10 V-25 °COtherAccording to IEC/EN 60068-2-610 - 55 Hz, Amplitude 0.5 mm0 V0 mmNone20 mmInsulated materialCuboid Product Range Catalog Sensors – products, basic information, applicationseaton-proximity-switches-proximity-switch-dimensions-024.epseaton-proximity-switches-e71-proximity-switch-3d-drawing.epsIL05305006ZDA-CD-90_28292_002DA-CS-90_28292_002Rated control supply voltage (Us) at AC, 50 Hz - min Response timeDiameter sensorSafety type (IEC 61496-1)LED indicatorCable sheath materialRated control supply voltage (Us) at DC - min Ambient storage temperature - minInterface typeVibration resistanceNumber of outputs (protected semiconductor)Rated control supply voltage (Us) at AC, 50 Hz - max Sensor heightExplosion safety category for gasSensor lengthSensor materialEnclosure type CataloguesDrawingsInstallation instructions mCAD modelAmbient operating temperature - max55 °CWire sizeTransmission range of the safety field0 mSwitching frequency500 HzOutput current (mA) - max100 mASwitching voltage of OSSD at state high30 VFeaturesStraight beamRated control supply voltage (Us) at DC - max30 VVoltage rating - max30 VAmbient operating temperature - min-25 °CElectric connection typeConnector M8Output current at protected output - max0 mALight dot size0 mm²Sensing modeLight-/dark switchingWidth sensor12 mmVoltage typeDCNumber of outputs (semiconductor with signaling function) 1Product categoryE71 NanoView SeriesOperating distance - min0 mmOperating temperature - min-25 °CAdjustment typeManual adjustmentLoad currentMax. 100 mA (Ie)Rated switching distance (Sn)350 mmOperating modeSwitching principle: Adjustable bright/dark switchingOperating distance - max350 mmOptical surface materialPlasticLight typeInfrared lightOperating temperature - max55 °CConnection typePlug-in connection M8 x 14-wireSwitch function typeOtherDegree of protectionNEMA 4IP66Number of outputs (protected contact energized)Ambient storage temperature - max70 °CNumber of contact energized outputs with signalling function 0Rated control supply voltage (Us) at AC, 60 Hz - min0 VOperation agent-safety classSafety class 2Eaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All rights reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaProtection against polarity reversal Short-circuit protection Reflected-light beam NPNPlasticNoneNone Optical sensors0 V0 mm880 nm30 g, Mechanical, Shock duration 11 ms 350 mmFunctionsSwitching output type Enclosure material Explosion safety category for dust Laser protection class TypeRated control supply voltage (Us) at AC, 60 Hz - max Reflector distance - min Wavelength of the sensor Shock resistanceSwitching distance - max。
卡罗洛·加瓦茨电子快速开关产品介绍说明书

•Contacteur moteur électronique àcourant alternatif •Commutation instantanée•Tripolaire avec options de commutation biphasée et triphasée•Indication du statut de la commande par DEL•Deux plages d’entrée de commande :15-32VCC,90-253VCA•Puissance nominale du moteur jusqu’à4kW /5,5CV •Tension nominale de service jusqu’à600VCA •Photocouplage à4kVrms•Ressemblance àun contacteur mécanique avec un dissipateur thermique recouvert •Rail DIN et montage sur panneauDescription du produitLégendes pour les commandesLe REC est un contacteur électronique conçu pour rem-placer la contrepartie mécanique traditionnelle util-isée pour le démarrage des moteurs triphasé gamme comprend des versions de commutation biphasée et triphasée de jusqu’à4kW et 600Vrms.Des options avec des pics de courant élevés et I²t àdes fins de fusion sont également disponibles.Le relais commute instantané-ment lorsque l’on applique la tension de commande pourémuler l’activation par un relais mécanique.Un dissipa-teur thermique couvert permet de résoudre toutes les ques-tions relatives aux câbles dis-posés àproximitédu dissipa-teur thermique et d’éviter d’avoir recours àdes câbles de terre protecteurs.Le pro-duit peut être montésur un rail DIN ou sur un panneau.N.B.:sauf mention contraire,les spécifications sont valables pour des températures de 25°C.ContacteurNombre de pôles Mode de Tension nominale Tension de Données de Option ITSM élevéType de connexion Type de connexion Configuration de la Contacteur moteur àsemi-conducteurs TriphaséTypes REC2B,REC3BLégendes pour les commandesPôles deMode deTension nominale Tension de Puissance Commande Connexion commutation commutation de fonctionnement commande nominale Itsm Commande/Power/Layout REC2:2pôles B:InstantON48:48-530VCA D:24VDC,-15%,2:2.2kW 0:ItsmG:Etrier +20%3:3.0kW Standard K:visREC3:3pôles60:48-600VCAA:90-253VCA4:4.0kW1:Itsm élevéE:ContacteurT ension No de pôlesT ension de commandePuissance maximum de régime nominale 2.2kW2.2kW*3.0kW4.0kW48-530Vrms224Vdc,-15%,+20%**REC2B48D20GKE -REC2B48D30GKE REC2B48D40GKE 90-253VCAREC2B48A20GKE -REC2B48A30GKE REC2B48A40GKE 324Vdc,-15%,+20%REC3B48D20GKE REC3B48D21GKE REC3B48D30GKE -90-253VCAREC3B48A20GKE -REC3B48A30GKE -48-660Vrms224Vdc,-15%,+20%--REC2B60D30GKE -90-253VCA--REC2B60A30GKE -324Vdc,-15%,+20%REC3B60D20GKE ---90-253VCAREC3B60A20GKE---*puissance ITSM plus élevée **conformément àEN61131-2Guide de sélectionSpécifications des connexionsCONNEXIONS DE POWER (75°C,câbles en cuivre)CONNEXIONSDECOMMANDE (75°C,câbles en cuivre)Spécifications de la charge(45mm d’espace entre les unités adjacentes)Spécifications environnementales Spécifications du logementIsolationT ension diélectriquede résistance,de l’entréeàla sortie≥4000V AC rms*Valable pour version VCC.Pour versions VCA,voir Critère de performance N°2.**This product is designed and constructed as an EMC Class A device.The use of this product in residential applications could lead to radio interferences.In such applications,additional external filtering may be required.DimensionsEMC (Compatibilitéélectromagnétique)Connexion àl’intérieur de deltaDiagrammes des connexionsCourbes caractéristiques et cycles de fonctionnementCourbes :Nombre de cycles de commutation par heure par rapport àtONNombre maximum de démarrages permissibles en fonction de Tn et de TonAccessoiresAdaptateur du relais de surcharge du moteur.*Numéro de pièce:REC3ADAPTORPack quantité:5unitésCompatible avec:Fabricant Séries ExempleABB TA TA25DU-8.5 Siemens3RU113RU1126-1FB0*1adaptor is shipped with every REC unit。
WIKA Instruments Italia Srl NI-401E温度开关说明书

INSTRUCTION MANUALNI-401E版本:10 04/20TEMPERATURE SWITCHES SERIE TAG AND TWG本手册提供的所有数据、声明和建议均基于我们认为可靠的信息。
由于有效使用条件超出了我们的控制范围,我们的产品销售条件是用户在遵循我们对其预期目的或使用的建议之前自行评价上述条件。
耐候且本质安全:PXS 系列; 隔爆: 隔爆:系列标签§不适用于标签系列A=护套连接 B=电缆入口X=有效长度 Y=插入长度 K=毛细管长度 表面安装时,使用M6螺钉重量2.1kg尺寸单位:mm重量2.9 kg尺寸单位:mm注意:尺寸和重量不是强制性的,除非在认证图纸上标注。
注意• 在安装、使用或维护仪表之前,有必要阅读并理解随附说明手册中给出的说明。
• 仪表必须由合有资质人员安装和维护。
• 只有在检查并确认仪表特性符合工艺和设备要求后,才能进行安装。
•仪器的功能特点及其防护等级显示在固定在外壳上的标识牌上。
内容1 - 一般说明2 - 工作原理3 - 型号代码4 - 标识牌和标记5 - 设定值调节6 - 设定值校准7 - 安装和连接8 - 仪表管道9 - 投入运行 10 - 目视检查 11 - 功能验证 12 - 停止和拆卸 13 - 处置14 - 温度开关,用于安全回路执行(SIL 执行) 15 - 故障排除在危险环境中使用的安全说明。
关于安全使用温度开关的建议。
1 - 一般说明1.1 前言系列或型号的错误选择以及不正确的安装会导致故障并缩短仪器寿命。
不遵守本手册中给出的指示可能会对仪表、环境和人员造成损害。
1.2 允许的超量程工作温度可偶尔超过工作范围,前提是温度保持在仪表特性(设计温度)中规定的范围内。
超过工作范围的连续温度可应用于仪表,前提是仪表特性中明确说明了这些压力。
不得超过技术规范和额定值中规定的电流和电压值。
短暂的超量程会对开关产生破坏性影响。
1.3 机械振动一般会导致仪器某些部件的磨损或造成误跳闸。
CKS 微型开关 A-71 产品说明书

A-71Dimensions are shown: Inches (mm)Specifications and dimensions subject to change Pushbutton8600 SeriesMicrominiature Pushbutton SwitchesFeatures/Benefits• Available with overtravel• Normally closed models available • M icrominiature size ideal for applications where space is limited • RoHS compliantTypical Applications• Detection • T elecommunications andnetworking equipment• Computers and peripheralsSpecificationsCONTACT RATING: Q contact material (8631, 8632 Models):500 mA @ 120 V AC or 28 V DC; 250 mA @ 250 V AC; (8633 Model): 250 mA @ 120 V AC or 28 V DC; 125 mA @ 250 V AC. See page A-73 for additional ratings.ELECTRICAL LIFE:8631 and 8633 MODELS: 250,000 actuations at full load. 8632 MODEL: 100,000 actuations at full load.CONTACT RESISTANCE: Below 30 mΩ typ. initial @2-4 V DC, 100 mA, for both silver and gold plated contacts.INSULATION RESISTANCE: 109 Ω min.DIELECTRIC STRENGTH: 500 Vrms min. @ sea level.OPERATING TEMPERATURE: –30ºC to 65ºC.SOLDERABILITY: Per MIL-STD-202F method 208D, orEIA RS-186E method 9.MaterialsCASE: Glass filled phenolic or diallyl phthalate (DAP), (UL94V-0).PLUNGER: Glass filled nylon (UL94V-0), black standard.BUSHING: Brass, nickel plated.CONTACTS: Q contact material: Coin silver, silver plated.See page A-73 for additional contact materials.TERMINALS:8631, 8632 MODELS: Copper alloy, silver plated. 8633 MODEL: Q contact material: Coin silver. See page A-73 for additional contact materials.TERMINAL SEAL:8633 MODEL: Epoxy.8631, 8632 MODELS: Terminals insert molded.HARDWARE: Nut: Brass, nickel plated.NOTE: Any models supplied with Q, B or G contact material are RoHS compliant. NOTE: Specifications and materials listed above are for switches with standard options. For information on specific and custom switches, consult Customer Service Center.Build-A-SwitchTo order, simply select desired option from each category and place in the appropriate box. Available options are shown and described on pages A-72 and A-73. For additional options not shown in catalog, consult Customer Service Center.Switch Function 8631 SPST Off-Mom.8632SPST Off-Mom.8633 SPST On-Mom.Contact Material B Gold Q SilverG Gold over silverSealDNo epoxy E Epoxy Plunger Color 2 Black 3 RedModels AvailableTermination Z Solder lug C PC Thru-holeA-72Dimensions are shown: Inches (mm)Specifications and dimensions subject to changeP u s h b u t t o n8600 SeriesMicrominiature Pushbutton SwitchesPC MOUNTING8631, 8632 models only.8633 models only.8631, 8632 models only.MOM. = MomentaryNOTE: Caps available for plunger options, see page A-73.Z SOLDER LUGC PC THRU-HOLEA-73Dimensions are shown: Inches (mm)Specifications and dimensions subject to change PushbuttonOPTION CODECOLOR 2BLACK 3RED8600 SeriesMicrominiature Pushbutton SwitchesAVAILABLE HARDWARE.187(4,75).081(2,03).245 DIA.(6,22 )NOTE: Other cap colors available, consult Customer Service Center.E EPOXY SEALD NO EPOXY SEALNot available on 8631, 8632 models.Standard on 8633 model only.Not available on 8633 model.Standard on 8631, 8632 models.CapPART NO.785101000WHITE 785102000 BLACK 785103000 REDMaterial: Nylon Finish: Gloss* Note: See Technical Data section of this catalog for RoHS compliant and compatible definitions and specifications.1 CONTACTS & TERMINALS: Copper alloy, with gold plate over nickel plate.2 CONTACTS: Coin silver, with gold plate over nickel plate.3 TERMINALS: C opper alloy, with gold plate over nickel plate.8633 model only: Coin silver, with gold plate over nickel plate.4 CONTACTS: Coin silver, silver plated.5 TERMINALS: Copper alloy, silver plated. 8633 model only: coin silver.NOTE: Any models supplied with Q, B or G contact material are RoHS compliant. 8631, 8632 modelswith all options when ordered with G or Q contact material.Q contact material standard with C, Z terminations.。
伊顿 传感器墙壁开关说明书

SPECIFICATIONS• Single Pole and 3-Way• 8.3A (1000W), 120V AC 60 Hz.• For Incandescent, Magnetic Low Voltage (MLV),Electronic Low Voltage (ELV), Fluorescent,Compact Fluorescent, LED, Motors up to 1/6 HP• Includes Selectable and Dimmable Nightlight• NOTE - A Neutral Connection is required in thewallbox where the sensor will be installedDESCRIPTION• This Sensor Wall Switch can replace astandard wall switch in any of the followingapplications:• Single location – one Single Pole switch• Two location – one location is the sensor andthe other location is a standard 3-way switch• Two location – replace both 3-Way switcheswith sensors• The OS310U turns on automatically when a personenters the room• The VS310U requires manual activation to turn onthe lights• Both OS310U and VS310U will automatically turn offlights after a selectable time delay• OS310U includes a light level adjustment fordaylight to prevent motion from turning on thelights• A green LED indicates the load status and provides a momentary flash to indicate motion OPERATION INSTRUCTIONSAuto ON Sensor – OS310U (Occupancy Mode):• OS310U will turn on lights automatically when a person enters the room• Lights will turn off automatically when no motion is detected after a selectable time delay• The selectable time delays are 5 seconds (Test Mode), 5 minutes (factory default), 15 minutes and 30 minutesManual ON Sensor – VS310U (Vacancy Mode):• The VS310U must be turned on manually with the ON/OFF button• Lights will turn off automatically when no motion is detected after a selectable time delay• The selectable time delays are 5 seconds (Test Mode), 5 minutes, 15 minutes and 30 minutes (factory default)• When the lights have turned off due to a lack of motion, the lights will turn ON automatically if motion is detected within 10 secondsNight Light• Press the Night Light lens momentarily to turn the Night Light ON or OFF• When the Night Light is ON, press and hold the Night Light lens to dim the Night Light to the desiredbrightness. Release when the desired brightness level is reached. Press and hold again to brighten• The OS310U can also operate as a Manual ON sensor when the Night Lite is ON. Refer to OS310USpecial Modes for additional explanationOS310U SPECIAL MODES• Reverse Mode: The reverse mode is used when the lights must stay OFF in a room while motion isdetected. If the lights are ON, a double tap of the ON/OFF button will turn off the lights and put the device into the Reverse Mode. This allows the lights to stay OFF as long as motion is detected. After the time delay is finished the sensor operation goes back to normal• Manual ON Only mode: This mode may be selected to prevent motion from automatically turning on the lights. Press and hold the ON/OFF button for 5 seconds until the indicator LED blinks. Release the button while the LED is blinking. Repeat this procedure to restore normal operation. While the OS310U is in the manual ON mode, it will behave like a VS310U• Override Mode: Turns off all motion sensing and allows the device to be used as a regular ON/OFFswitch or in the unlikely event of a failure of the motion sensor. Press and hold the ON/OFF button for 10 seconds until the indicator LED blinks for the second time (the LED will also blink at the 5 second point).Release the button while the LED is blinking. Repeat this procedure to restore normal operation• Manual ON Mode with Night Light ON (Child Bedroom mode): This feature is popular for a child bed room application. When the sensor is in the Automatic mode and the Night Light is ON, the sensor will operate in the Manual ON mode. This feature can be enabled by pressing and holding the Night Light button for 5 seconds while the Night Light is OFF. The Night Light will blink after 5 seconds. Release the button while the night light is blinking. Repeat this procedure to restore normal operation• Disable Manual Operation– In this mode the sensor will function normally with automatic sensing,however the sensor will not respond to pressing the ON/OFF button. This feature only applies to theOS310U when used in the Automatic mode. This feature is enabled by pressing and holding the ON/OFF button for 15 seconds until the LED indicator blinks for the third time (the LED will also blink at the 5second and 10 second point) and then releasing the button while the LED is blinking. Repeat thisprocedure to restore normal operationINSTALLATION INSTRUCTIONSWARNING:•Turn OFF circuit breaker or remove fuse(s) and verify that power is OFF before wiring•Never wire any electrical device with power turned ON. Wiring the device with the power ON may cause permanent damage to the device and void the warranty•If you are unsure about any part of these instructions, or if the wiring does not match the descriptions given, you should call a qualified electricianCAUTION:• Must be installed and used in accordance with all applicable electrical codes• If a bare copper or green ground connection is not available in the wallbox, contact a qualifiedelectrician for installation• Do not install without proper ground connections• Do not exceed maximum device ratingsEATON WIRING DEVICES LIMITED 2 YEAR WARRANTYEaton Wiring Devices (Eaton) warrants this device to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original purchase. THIS 2 YEAR LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF 2 YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF EATON HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF EATON UNDER THIS WARRANTY.To obtain warranty service for any properly installed Eaton device that proves defective in normal use send the defective device prepaid and insured to Quality Control Dept., Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in Canada: Eaton Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. Eaton will repair or replace the defective unit, at its option. Eaton will notbe responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper installation, alteration, improper maintenance or repair of damage in shipment to Eaton.EATON SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE DEVICE, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL, CONTINGENT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE DEVICE OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT.For 2 sensor applications, wire the sensor switches according to wiring diagram #3 using the wire nutsprovided.COMPLETING THE INSTALLATION:1. Secure sensor into the wall box using two mounting screws provided. Turn thecircuit breaker ON.2. Allow the sensor to stabilize for 10 seconds. The sensor is now ready to detectmotion.3. Verify that Power in ON by pushing the ON/OFF button. Lights and LED should turnON.4. NOTE - The sensor time delay is factory preset (OS310U = 5 minutes; VS310U =30minutes).5. If you want to change the time delayproceed as follows:pressing in the hooks on the button,and then lift up on the button asshown in Fig. 4.b. Set the time delay using the dial onscrewdriver. Align the arrow on thedial to desired time delay.c. To allow the installer to quicklyproperly the time delay can be set toTEST. This will set a time delay of 5 seconds, which allows quick feedbackthat the sensor is working properly.6. Replace push button by sliding it upward into the slots in the front housing andpush down until the button hook snaps into place.7. Push the ON/OFF button to verify that the lights turn ON/OFF, and that the buttonoperates freely.8. Install the wallplate.Daylight Sensing Adjustment (OS310U only):• The Daylight sensing feature prevents lights from turning ON when the room isadequately illuminated by natural light.• NOTE - The factory setting for this adjustment is fully clockwise and permitsmotion detection to turn ON the lights regardless of the ambient light level inthe room. If the Night Light is ON the daylight feature is disabled.• Remove the ON/OFF pushbutton to access the light level adjustment. See Fig. 5.• This adjustment must be made when the light level in the room is at the desiredlevel for the lights to turn ON.• From the clockwise position, turn the dial on the left counterclockwise using asmall Phillips screwdriver until the NightLight turns ON.• Step away from the sensor to allow thein the room.Do not obstruct the natural light. Thecalibration process starts when the Nightturn on.• Replace the ON/OFF push button TROUBLESHOOTING:SYMPTOM POSSIBLE CAUSE SOLUTIONLight does not turn ON 1. Circuit breaker or fuse is turned OFF,or fuse is blown2. Bulb is defective3. Poor connection4. Control may be wired incorrectly5. Daylight sensing prevents lights on6. Manual ON mode selected1. Turn circuit breaker ON, or replace fuse2. Replace light bulb3. Verify all wiring connections4. Check wiring5. Re-adjust daylight sensing level6. Set device to Automatic ON modeLight does not automatically turn OFF 1. Motion is still present2. Time Delay has not expired3. Control may be wired incorrectly4. Switch is being triggered by air ventor other heat source1. Make sure there is no motion during thetime delay period2. No action needed or shorten TIME DELAY3. Check wiring4. Move switch to the other switch location(if a 3-Way), or determine the sourcetriggering the switch, and alter the air flowLight does not automatically turn ON 1. Motion is not detected2. TIME control is set for too short a delay1. Create movement in front of the sensorfor 5 seconds2. Set switch TIME control to longertime periodRemote switch does not work 1. Control may be wired incorrectly 1. Check wiringDIAGRAM 1: SENSOR IN ONE LOCATION / SCHÉMA 1: DÉTECTEUR EN UN EMPLACEMENT / DIAGRAMA 1: SENSOR EN UNA (1) UBICACIÓNDIAGRAM 5 / SCHÉMA 5 /DIAGRAMA 5:1. Remove the existing switch in the location where the sensor will be installed.a. The sensor black wire will connect to either one of the black wires in the wallbox.b. The sensor red wire will connect to the other black wire in the wall box.c. The sensor white wire will connect to the neutral wire (white) in the wallbox.d. The sensor blue wire will connect to the red traveler wire in the wallboxe. The sensor green wire will connect to the ground wire in the wallbox.f. Install the sensor loosely using the mounting screws provided.2. Remove the existing switch in the other 3-way location.a. Connect the two black wires together.b. Connect the white wires together and also connect the white wires to the common terminal (usually ablack screw or a marking such as COM or COMMON near the terminal) on the 3-way switch.c. Connect the red wire to either of the other switch terminals.d. Re-install the 3-way switch and tighten securely.3. Apply power and verify that the sensor works by pushing the ON/OFF button. The lights should turn ON andOFF. If the lights do not work, then turn the power off and swap the connections to the sensor black andred wires.4. Apply power again and verify the sensor works by pushing the ON/OFF button to verify the lights turn ON andOFF.5. Turn power OFF and go to COMPLETING THE INSTALLATION.DIAGRAM 2A: SWITCH IN LOCATION WITH HOT WIRE / SCHÉMA 2A: INTERRUPTEURSUR L’EMPLACEMENT AVEC FIL DE PHASE / DIAGRAMA 2: INTERRUPTOR EN UBI-CACIÓN CON ALAMBRE DE ENERGÍAa. The sensor black wire will connect to the two black wires in the wallbox.b. The sensor red wire will connect to the red wire in the wall box.c. The sensor white wire will connect to the neutral wire (white) in the wallbox.d. The sensor blue wire is not used and should be capped off with a wire nut.e. The sensor green wire will connect to the ground wire in the wallbox.f. Install the sensor loosely using the mounting screws provided.2. Remove the existing switch in the other 3-way location where the second sensor will be installed.a. The sensor black wire will connect to the black wire coming from the first wallbox.b. The sensor red wire will connect to the red wire coming from the first wallbox and to the black wiregoing to the light fixture.c. The sensor white wire will connect to the neutral wire (white) in the wallbox.d. The sensor blue wire is not used and should be capped off with a wire nut.e. The sensor green wire will connect to the ground wire in the wallbox.f. Install the sensor loosely using the mounting screws provided.3. Apply power and verify that the sensors work by pressing the ON/OFF buttons on each sensor. The greenLEDs on the sensors should turn on and off. If the LED does not work on either or both sensors, you mustswap the red and black sensor wire on that sensor.4. Re-install the sensor loosely, apply power again, and verify the sensor works by pushing the ON/OFFbutton to verify the green LEDs and the lights turn ON and OFF.5. Turn power OFF and go to COMPLETING THE INSTALLATION.DIAGRAM 3: SENSORS IN BOTH LOCATIONS / SCHÉMA 3: DÉTECTEUR SUR LES DEUX EMPLACEMENTS /DIAGRAMA 3: SENSORES EN AMBAS UBICACIÓNES• For use ONLY with permanently installed fixtures of these types: Incandescent/Halogen, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV),Fluorescent, Compact Fluorescent, LED• May also be used with motors up to 1/6 HP• To avoid overheating and possible damage to other equipment, do not use tocontrol receptacles• Use only #14 or #12 copper wire with these devicesRefer to the wiring diagrams and install the sensor according to these directions.You must verify that a neutral wire is available in the wallbox.For single pole applications, wire the sensor switch according to wiring diagram #1using the wire nuts provided.1. The sensor black wire will connect to the hot wire (black) in the wallbox.2. The sensor red wire will connect to the wire which goes to the light fixture.3. The sensor white wire will connect to the neutral wire (white) in the wallbox.4. The sensor blue wire is not used and should be capped off with a wire nut.5. The sensor green wire will connect to the ground wire in the wallbox.6. Install the sensor loosely using the mounting screws provided.7. Apply power temporarily and verify that the sensor works by pushing the ON/OFF buttonto verify the lights turn on and off. If the lights do not work, then turn off the power andswap the connections on the sensor black and red wires8. Apply power again and verify that the sensor works by pushing the ON/OFF button toverify the lights turn on and off.9. Turn power OFF and go to COMPLETING THE INSTALLATION.For 3-way applications NOTE that the 3-way switch is NOT wired in the traditional 3-way manner. Wireaccording to either diagram 2A or 2B using the wire nuts provided. The sensor may be placed at either endof the 3-way circuit./wiringdevicesEIS-0155-E (REV.A)。
晓风电子AS431可调精密漏电调节器说明书

DescriptionThe AS431 is a three-terminal adjustable shunt regulator with guaranteed thermal stability over a full operation range. It features sharp turn-on characteristics, low temperature coefficient and low output impedance, which make it ideal substitute for Zener diode in applications such as switching power supply, charger and other adjustable regulators.The output voltage of AS431 can be set to any value between VREF (2.5V) and the corresponding maximum cathode voltage (36V).The AS431 precision reference is offered in two voltage tolerance: 0.5% and 1.0%.This IC is available in 4 packages: TO92 (Ammo Packing), SOT23, SOT25 and SOT89.Features∙ Programmable Precise Output Voltage from 2.5V to 36V ∙ High Stability under Capacitive Load ∙ Low Temperature Deviation: 4.5mV Typical∙ Low Equivalent Full-range Temperature Coefficient with 20PPM/°C Typical ∙ Sink Current Capacity from 1mA to 100mA ∙ Low Output Noise∙ Wide Operating Range of -40 to +125°C∙Lead-Free Packages: SOT23, SOT25, TO92 (Ammo Packing), SOT89 ▪ Totally Lead-Free; RoHS Compliant (Notes 1 & 2) ∙Lead-Free Packages, Available in “Green” Molding Compound: SOT23, SOT25, TO92 (Ammo Packing), SOT89 ▪ Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2) ▪ Halogen and Antimony Free. “Green” Device (Note 3)Applications∙ Charger ∙ Voltage Adapter ∙ Switching Power Supply ∙ Graphic Card∙Precision Voltage ReferencePin Assignments(Top View) (Top View)SOT23 SOT25Note 4: * Pin 2 is attached to substrate and must be connected to ANODE or open.(Top View) (Top View)SOT89 (Option 1) SOT89 (Option 2)(Top View)TO92 (Ammo Packing)Notes: 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS), 2011/65/EU (RoHS 2) & 2015/863/EU (RoHS 3) compliant.2. See https:///quality/lead-free/ for more inf ormation about Diodes Incorporated’s definitions of Halogen - and Antimony-free, "Green" and Lead-free.3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm tot al Br + Cl) and<1000ppm antimony compounds.ANODECATHODEREF321123REFCATHODEANODE 123REFCATHODEANODE REFCATHODE ANODE12345NC (Note 4)*REF CATHODEANODE 123Typical Applications CircuitShunt RegulatorHigh Current Shunt RegulatorCurrent Source or Current LimitTypical Applications Circuit (Cont.)Precision 5V 1A RegulatorPWM Converter with ReferenceFunctional Block DiagramAbsolute Maximum Ratings (Note 5)Symbol Parameter Rating Unit V KA Cathode Voltage 40 VI KA Cathode Current Range (Continuous) -100 to 150 mAI REF Reference Input Current Range 10 mAP D Power Dissipation Z, R Package 770mW N, K Package 370T J Junction Temperature +150 °CT STG Storage Temperature Range -65 to +150 °CESD ESD (Human Body Model) 2000 V functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Conditions” is not implied.Exposure to “Absolute Maximum Ratings” fo r extended periods may affect device reliability.Recommended Operating ConditionsSymbol Parameter Min Max Unit V KA Cathode Voltage V REF36 VI KA Cathode Current 1.0 100 mAT A Operating Ambient Temperature Range -40 +125 °CElectrical Characteristics (Operating Conditions: T A = +25°C, unless otherwise specified.)Electrical Characteristics (Cont.)Test Circuit 4 for V KA = V REFTest Circuit 5 for V KA > V REFTest Circuit 6 for I OFFPerformance CharacteristicsReference Voltage vs. Ambient Temperature Reference Current vs. Ambient TemperatureCathode Current vs. Cathode Voltage Cathode Current vs. Cathode VoltageOff-State Cathode Current Ratio of Delta Reference Voltage to thevs. Ambient Temperature Ratio of Delta Cathode VoltageR e f e r e n c e V o l t a g e (V )Ambient Temperature (o C)R e f e r e n c e C u r r e n t (μA )Ambient Temperature (0C)C a t h o d e C ur r e n t (m A )Cathode Voltage (V)C a t h o d e C u r r e n t (μA )Cathode Voltage (V)O f f -S t a t e C a t h o d e C u r r e n t (μA )Ambient Temperature (oC)∆V R E F / ∆V K A (m V /V )Ambient Temperature (oC)Performance Characteristics (Cont.)Small Signal Voltage Gain vs. FrequencyReference Impedance vs. FrequencyStability Boundary Conditions vs. Load CapacitanceV o l t a g e G a i n (d B )Small Signal Frequency (Hz)R e f e r e n c e I m p e d a n c e (Ω)Frequency (Hz)C a t h o d e C u r r e n t (m A )Load Capacitance (μF)Performance Characteristics (Cont.)Pulse Response of Input and Output VoltageInputandOutputVoltage(V)Time ( S)Ordering InformationA : 0.5% Z : TO92(Ammo Packing)N : SOT23TR : Tape & Reel orAmmoG1 : RoHS Compliantand GreenB : 1.0%K : SOT25R : SOT89E1 : RoHS CompliantPbLead-Free PbLead-FreePbLead-FreePbLead-FreePbLead-FreePbLead-FreePbLead-FreePbLead-FreeOrdering Information (Cont.)Notes: 6. All variants with TO92 package in Bulk packing (AS431AZ-E1, AS431BZ-E1,AS431AZ-G1 and AS431BZ-G1) are End of Life, recommendedalternatives are the variants with the same package in Ammo packing.NRND: Not Recommended for New Design.7. For packaging details, go to our website at: https:///design/support/packaging/diodes-packaging/.Marking Information(1) TO92 (Ammo Packing)(Front View)First and Second Lines: Logo and Marking ID (See Ordering Information) Third Line: Date Code Y: YearWW: Work Week of Molding A: Assembly House Code XX: Internal CodeAS431 XZ-XX YWWAXX PbLead-FreePbLead-FreeMarking Information (Cont.)(2) SOT23(Top View)(3) SOT89 (Top View)(4) SOT25(Top View)321XXX: LogoXXX: Marking ID (See Ordering Information)First Line: Logo and Marking ID (See Ordering Information) Second Line: Date Code Y: YearWW: Work Week of Molding A: Assembly House Code XX: Internal Code: LogoXXX: Marking ID (See Ordering Information)XXX23XXXX YWWAXX 1 XXXXYWWAXX231Package Outline Dimensions (All dimensions in mm(inch).)(1) Package Type: TO92 (Ammo Packing)Ty pPackage Outline Dimensions (Cont. All dimensions in mm(inch).)(2) Package Type: SOT23(3) Package Type: SOT251.300(0.051)(4) Package Type: SOT89Option 1Option 2Suggested Pad Layout(1) Package Type: SOT23Grid placement courtyardSuggested Pad Layout (Cont.)(2) Package Type: SOT25Suggested Pad Layout (Cont.)(3) Package Type: SOT89Z。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
3.额定负荷和寿命 额定负荷
4.电气性能:
项目
4.1 绝缘电阻
4.2 抗电强度 5.机械性能
项目
5.1 操作力
5.2 回复力
负荷寿命 参见产品图纸。
机械寿命
标准
100MΩ Min. 无击穿现象发生。
标准
参见产品图纸. 参见产品图纸.
E43大电流微动开关规格书由肖志刚整理提供,请联系索取最新规格书资料!
TONELUCK
E-mail: 624364157@qq.com
www.toneluckswitch.com
拟制: 审核: 批准:
TONELUCK Micro
产品规格书
客户编码: 项目代号:
Toneluck 编码: E43AN-AA13Ag-01 产品版本: A001
z 安装孔加工图,请以下图为准
安装孔加工图 2-Φ3.1 孔或 2-M3 螺丝孔
开关操作上的注意点 (1) 操作体要完全离开开关的按挚,并且要留出
动作时所需的移动量。
(2) 设定的过行程值,是在开关动作之后的移动
量,以动作后达 OT 值(Min 表示)的 60~
90%为宜。
(3) 操作伴有惯性冲击时,请事前另外协商。
TONELUCK Micro
产品规格书
客户编码: 项目代号:
Toneluck 编码: E43AN-AA13Ag-01 产品版本: A001
页码: 1 / 5 发布日期: 2010-11-16
File/Edition:E43AN-AA13Ag-01-SPC.001
产品名称: 微动开关 客户名称: 客户编码: 客户代表:
7.耐候性能:
项目
7.1 低温
7.2 高温
标准
实验方法
实验后, -绝缘电阻 : 50MΩ Min. -抗电强度应符合第 4.2 条的要 求。 -操作力变化在±10%以内。 -开关外观及结构应无损坏。
试件在-40±3oC 的温控箱内保持 96 小时,然后在正常温度和 湿度下恢复 1 小时,并在此后 1 小时内对试品进行测量,水滴 应消失。
页码: 2 / 5 发布日期: 2010-11-16
1. 一般特性: 1.1 适用范围: 1.2 使用温度范围: 1.3 相对湿度: 1.4 实验条件:
2. 外观,结构及尺寸: 2.1 外观 : 2.2 结构及尺寸 : 2.3 标识 : 2.4 通过的安全认证 :
该规格书指微动开关的一般使用范围。 参见产品图纸。 ≤96%RH ,+40oC 若没有特别说明,则试验大气条件如下 : 环境温度 : 5~35oC 相对湿度 : 45~85%RH 大气压力 : 86~106kPa (860~1060mbar)
z 一般保存温度湿度:温度 5~35℃,湿度≤80%RH。
TONELUCK
E-mail: 624364157@qq.com www.toneluckswitch.com
7.4 温度转换
室温. in
10~15min 10~15min 1次
附注: 操作参数示意图
OF : 操作力(Operating Force) RF : 回复力 (Release Force) TF : 全行程力 (Total travel Force) FP : 自由位置 (Free Position) OP : 动作位置 (Operating Position) TTP : 全行程位置 (Total Travel Position) RP : 释放位置 (Release Position ) PT : 行程 (Pre Travel) OT : 过行程 (Over Travel) MD : 差动行程 (Movement Differential Travel) TT : 全行程 (Total Travel)
TONELUCK Micro
产品规格书
客户编码: 项目代号:
Toneluck 编码: E43AN-AA13Ag-01 产品版本: A001
页码: 5 / 5 发布日期: 2010-11-16
注意事项
1 开关的安装
1.1 开关的安装和加工
z 在紧固开关时,建议使用带扭矩刻度的螺丝刀,用 4-6kg.cm 扭矩进行紧固。(螺丝为 M3 规格)
产品规格书
页码: 3 / 5 发布日期: 2010-11-16
5.7 振动
实验后, -绝缘电阻 : 50MΩ Min. -抗电强度应符合第 4.2 条的要 求。 -应无明显外观损坏。 -操作力误差应在±10%之内。 -表面及结构无明显变形。
开关采用常规的安装方法牢固地安装在试验设备上,并在下 述参数条件下进行试验: (1)振频 = 10~55 Hz (2)振幅 = 1.5mm (3)振动变化速率: 10~55~10Hz 大约 1 分钟 (4) 变频方法:对数或线性形式 (5) 振动方向:三个相互垂直的方向,其中一个方向应是促动
实验方法
在相互绝缘的所有端子之间及各接线端子与外露的非载流金属 零件之间加载 500±50V 直流电,持续时间 60±5 秒。 在相互绝缘的所有接线端子之间加载 1000V(50~60Hz,泄漏电 流 10mA)交流电,各接线端子与外壳或非载流金属零件之间加 载 1500V(50~60Hz,泄漏电流 10mA)交流电,持续时间 60±5 秒。
元件运动的方向。 (6)时间:每个方向 2 小时(共 6 小时)。
5.8 冲击
6.寿命试验:
项目
试件在下述参数条件下进行试验: (1)安装方法 : 常规方法 (2)加速度 : 490m/s2 (50G)
实验后, -绝缘电阻 : 50MΩ Min. -抗电强度应符合第 4.2 条的要 求。 -操作力误差应在±10%之内。 -表面无变形且操作无异常。
6.2 负荷寿命
实验后: -绝缘电阻 :50MΩ Min. -抗电强度应符合相应标准的要 求。 -操作力变化在±20%以内。 -开关外观及结构应无损坏
①按 UL1054 的标准进行相应次数的负荷寿命试验(额定负荷参 见产品图纸)。 ②按 IEC61058.1 的标准进行相应次数的负荷寿命试验(额定负 荷参见产品图纸)。
试件在 85±2oC 的温控箱内保持 96 小时,然后在正常温度和 湿度下恢复 1 小时,并在此后 1 小时内对试品进行测量。
TONELUCK Micro
产品规格书
客户编码: 项目代号:
Toneluck 编码: E43AN-AA13Ag-01 产品版本: A001
页码: 4 / 5 发布日期: 2010-11-16
(4) 操作体的设置,应考虑微动开关的操作力。
1.2 安装开关时的绝缘配线
安装侧的框架为金属时,请注意端子配线与各框架金属面的空间距离。
1.3 开关端子配线
给端子配线时,请选用适当插座、电线,确认没有晃动和松动。(请参照规格书图纸上的端子
规格)。
2 开关的保管
z 请避开污染气体、有机气体产生的地方(如石油暧炉附近等),灰尘、潮湿环境等。
参见产品图纸.
从动作位置到释放位置的距离
-端子无松动,损坏及绝缘层的 破裂。 -电气性能应符合第 4 部份的要 求。
以 89N 作用力沿轴向逐渐施加于接线端末端,作用力方向为离 开开关向外指向,保持 10±1 秒,每个接线端子测量一次。
TONELUCK Micro
客户编码: 项目代号:
Toneluck 编码: E43AN-AA13Ag-01 产品版本: A001
产品型号: E4(系列) Toneluck编码: E43AN-AA13Ag-01
项目代号:
接收: 签名:
规格书确认
职务: 日期:
备注:
1. 该《规格书》为客户与惠达公司在技术方面的共识,其它相关资料上与该《规格书》不一致的内容都是无效 的。
2. 如果顾客收到《规格书》后没有信息反馈而直接向我公司订货,我们将认为顾客已接受此《规格书》。
7.3 恒定湿热
试件在 40±2oC,90~95%RH 的温控箱内保持 96 小时,然后在 正常温度和湿度下恢复 1 小时,并在此后 1 小时内对试件进行 测量,水滴应消失。 试件按下述实验条件试验 5 次,然后在正常温度和湿度下恢复 1 小时,并在此后 1 小时内对试品进行测量,水滴应消失。
85±2oC
(3) 时间:
11 ms
(4)实验方向 :图示 6 方向
(5)冲击次数 : 每个方向 3 次
(总共 18 次)
标准
实验方法
6.1 机械寿命
实验后: -绝缘电阻 :50MΩ Min. -抗电强度应符合第 4.2 条的要 求。 -开关外观及结构应无损坏
在不带负荷的条件下,以 200~300 次/分的操作频率在寿命试 验设备上连续转换(转换次数参见产品图纸)。
实验方法
在操作元件末端沿操作方向均匀施加静载荷,使操作元件转换 到动作位置。
在操作元件末端沿操作方向均匀减少静载荷,使操作元件从动 作位置转换到释放位置。
5.3 动作位置
参见产品图纸.
开关发生转换时,操作元件未端到开关安装孔中心的距离
5.4 行程
参见产品图纸.
从自由位置到动作位置的距离
5.5 差程 5.6 接线端强度