BUSSMANN熔断器底座BM_Series
BUSSMANN熔断器产品手册

Circuit Protection Solutions Low Voltage Fuse Links CatalogueTable of ContentsDomestic Applications to BS1361 & BS1312Consumer Unit Fuse Link4Plug T op Fuse Links4Industrial & Motor Applications to BS88Offset Bolted Tags 5 - 7 Centre Bolted T ags8 - 9 Offset Blade Tags10Merchandising Stand11Industrial Applications to BS88 - 500VdcSpecial DC Range Offset/Centre Bolted Tag12Industrial Applications to BS88 - 660/690VOffset Bolted Tags 13 Centre Bolted T ags14 Special Tag Arrangements15Street Lighting Applications to BS88Offset Bolted Tags16Utility Applications to BS88House-Service Cut-Out Fuse Links17 J Type Fuse Links to BS88: Part 5 Cylindrical17 J Type Fuse Links to BS88: Part 5 Slotted/Non Slotted 18Joint NATO Reference SystemCylindrical/Offset Bolted T ag19BS88 FuseholdersCamaster HRC Fuseholder20 Safeloc Fuseholder21Cylindrical Domestic Fuses22Domestic Fuses23Cylindrical Industrial FusesClass gG 24 Class aM25 CHD26 CHM27 CH28NH Fuses - Dual IndicatorClass gG - Low Power Loss29 - 30 Class gG 31 Class aM32 -33 Class gG - aM34NH Fuses - Dimensions35NH Fuseholders for Knife Fuses36 Dimensions for Knife fuse and Fuseholders (NH)37 - 38 NH Fuse Rails and Disconnectors39 - 41DO Fuses42DO Fuseholders43D Fuses44D Fuseholders45Other Low Voltage Fuse Ranges 46Medium Voltage Fuses and Isolators47Ultra Fast Fuses and Holders48 - 49Domestic Applications to BS1361 & BS1312Offset Bolted Tags 240 - 550V ac / 2 - 32ASpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantFixing Unit Part No Dimensions (mm)A B C D E F G NITD 55.04434.611.213.80.814.0NITD32M35.617.51.218.5Part No Dimensions (mm)A B C D E F G H AAO 857335.513.714 1.28.78.0AAO32M54.52122.3Volts:-415 - 550V ac Amps:- 2 - 32AIR -80kA @ 415/550V acData Sheet:4106Data Sheet:4109Offset Bolted Tags (Cont.../...)240-550V / 32 - 100ASpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) and CSA C22.2 No 106-M 1985RoHS CompliantPart No Dimensions (mm)A B C D E F G H J BAO 877354.52122.51.212.78.05.5BAO63MPart No Dimensions (mm)ABC DEFGHJCEO 1109458.521.024.53.214.311.08.7CEO100M125 &16025.826.8CEO100M20047.03129.519.010.09.0Volts:-415 - 550V ac Amps:-32 - 100AIR -80kA @ 415 / 550V acOffset Bolted Tags (Cont.../...)240 - 550V ac / 80 - 200ASpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantPart No Dimensions (mm)A B C D E F G H J OSD 95.07354.521.022.5 1.212.78.05.5OSD100M26.025.7Part No Dimensions (mm)A B C D E F G H J DEO 1109447.031.029.53.219.010.09.0DEO200MVolts:-415 - 550V ac Amps:-80 - 200AIR -80kA @ 415 / 550V acCentre Bolted Tags415 - 550V ac / 2 - 1250A 250V dcSpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantPart NoA B AC 113.597.5AD 128.5111BC 113.597.5BC63M BD 128.5111CD126111CD100M125 & CD100M160CD100M200136DD 136111DD200M ED250136111ED315ED315M4009.0ED400M500Volts:-415 - 550V ac / 250V dc Amps:- 2 - 1250AIR -40kA @ 250V dc-80kA @ 415 / 550V acData Sheets:AC:4110 / BC:4113 / AD:4111 / BD:4114 / CD:4116 / DD:4118 / ED:4119Centre Bolted Tags (Cont.../...)415 - 550Vac / 125 - 1250A 250 - 400VdcSpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantFG / GG / GH550V ac / 450 - 1250A 250V dc (Type GG 710-800A only)400V dc (Type FG)Catalogue NumbersDimensionsDimensionsUnit Interrupting Volts:-415 - 550V ac / 250V dc Amps:- 2 - 1250AIR-40kA @ 250V dc GF, GG except 1000 & 1250A -40kA @ 400V dc FG, FF -80kA @ 415/550V acData Sheets:EFS:4121 / EF:4120 / FF:4102 / GF:4103Data Sheets:FG:4122 / GG:4104 / GH:4108Offset Blade Tags 240 - 550V / 2 - 63ASpecificationsDescription:Fuse Links for generalindustrial applications with Q1 fusing factor -general purpose (gG) and motorprotection (gM) characteristics.Ratings:Applications:General Industrial and Motors applicationsAgency Information:Meets BS88: Part 6, 1988 and IEC 269: Parts 1, 1986RoHS Compliant DimensionsCatalogue NumbersIndustrial & Motor Applications to BS88Volts:-240V ac (SSD)-415V ac (NSD gM) / ESD gG (40 - 63A)-550V ac (NSD gG) / ESD gG (2 - 32A)Amps:- 2 - 63AIR -33kA @ 240V ac -80kA @ 500V acData Sheet SSD:4105Data Sheet NSD:4100Merchandising Stand SpecificationsDescription:Merchandising stand with BS88 fuses packed in packs of 3’s or 10’s Stand dimensions:1.88 Metre tall x 0.91 Metre wide x 0.51 Metre deep* (including hooks)Catalogue NumbersPoint of Sale StandPlease note this stand is for the UK market onlyFor Product Data Sheets, visit Special DC RangeOffset/Centre Bolted Tag 500Vdc / 10 - 63ASpecificationsDescription:Fuse links for industrial DC applications available in offset and centre bolted tags Ratings:Applications:Protection of DC electrical circuits Agency information:ASTA approved to BS88 part 2RoHS Compliant DimensionsCatalogue NumbersVolts:-500V dc Amps:-10 - 63AIR -40kA @ 500V dcData Sheet:E578501712For Product Data Sheets, visit Offset Bolted Tags 660-690V / 2 - 200ASpecificationsDescription:Fuse links for industrial applications at 660/690V that meets dimensional and performancerequirements of BS88 and IEC 269-1-2standardsRatings:Applications:Protection of large industrial installations at 600/690VacAgency information:Meets BS88: Part 1 & 2 and IEC 269: Parts 1 & 2RoHS CompliantCatalogue NumbersVolts:-660 / 690V ac -250V dc (2 - 63A)-400V dc (80 - 200A)Amps:- 2 - 200AIR -80kA @ 660V ac -40kA @ 400V dcData Sheet H07:4150Data Sheet K07:4151Data Sheet L14:4152Data Sheet M14:415313For Product Data Sheets, visit Centre Bolted Tags660 - 690V ac / 2 - 630A 250 - 400V dcSpecificationsDescription:Fuse Links for industrial applications at 660/690V that meets dimensional and performancerequirements of BS88 and IEC 269-1-2standards.Ratings:Applications:Protection of large industrial installations at 660/690VacAgency Information:Meets BS88: Part 1 & 2 and IEC 269: Parts 1 & 2RoHS Compliant DimensionsCatalogue NumbersIndustrial Applications to BS88 - 660/690VDimensions (mm)A B C D E F G 111.092.553.722.02.412.713.0111.593.054.225.0127.011153.722.0 2.414.015.2128.011154.225.0Part NoDimensions (mm)A B C D E F G L09-660136.011165.535.5 3.219.015.18.7M09-660135.011165.037.0 3.219.015.08.7N09-660135.011173.049.0 3.225.412.79.5P09-660135.511175.058.5 4.725.412.79.5N11-660162.013373.049.03.225.415.810.5Volts:-660 / 690V ac-250V dc (2 - 63A) (K08, K09)-400V dc (80 - 630A) (L09, M09, N09,P09, N11, P11, P12, R11, R12)Amps:- 2 - 630AIR-80kA @ 660V ac-40kA @ 250V dc/400V dcData Sheets:K08:415 / L09:4156 / M09:4157 / N09:4158 / P09:4159 / N11:4160 / P11:4161 / R11:4162 / R12:416214Low Voltage Fuse Links Catalogue For Product Data Sheets, visit Special TagArrangements 660 - 690V / 125 - 800ASpecificationsDescription:Fuse Links for industrial applications at 660/690V that meets dimensional and performancerequirements of BS88 and IEC 269-1-2standards.Ratings:Applications:Protection of large industrial installations at 600 / 690VacAgency Information:BS88 part 1 section 2-1 & 2-2RoHS Compliant Dimensions Catalogue NumbersIndustrial Applications to BS88 - 660/690VPart No Dimensions (mm)A B C D E F GH M13120.099.070.038.027.08.026.012.0M23262.0231.0167.038.519.014.0N15120.0100.079.049.041.016.515.0Dimensions (mm)Offset Bolted TagCentre Bolted TagSpecial T ag ArrangementVolts:-660 / 690V ac (except S20 type - 550V ac)-400V dc (except S20 type)Amps:-125 - 800AIR -80kA @ 660V ac-40kA @ 400V (except S20 type)Data Sheets:M13 & M23:4153 / N15:4164 / N34:4165 / P35:4161 / R40:4162 / N20:4166 / P20:4167 / R20:4168 / S20:E578504515For Product Data Sheets, visit Offset Bolted Tags 240 - 550V / 2 - 32ASpecificationsDescription:Fuse Links for general street lightingapplications with Q1 fusing factor - general purpose (gG) Applications:Street lighting applicationsSMD415V ac (gG) / 2 - 32AStreet Lighting Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantSTD240V ac /2 - 32ACatalogue NumbersDimensionsCatalogue NumbersDimensions Volts:-240 - 415V ac Amps:- 2 - 32AIR -33kA @ 240V ac (STD)-80kA @ 415 / 550V ac (SMD)Data Sheet:412316Also available as Offset Bladed T ags “SSD”, see page 10For Product Data Sheets, visit House Service Cut-Out Fuse Links 415V / 5 - 100ASpecificationsDescription:Cylindrical Fuse Links for electrical utilities to BS Standard Ratings:Applications:Fuses to use in connection with House Service cut-outs.Agency Information:ASTA certified and tested in accordance to BS 1361RoHS Compliant Catalogue NumbersJ Type Fuse Links to BS88:Part 5 Cylindrical Type 415V / 20 - 250ASpecificationsDescription:Cylindrical type fuses designed for use with wedge type fuse carriers on BS applications Ratings:Applications:For use by Electrical Authorities in distribution pillars, open type substation boards,heavy duty cut-outs, and underground connection boxes. Cylindrical type to be used in pole or wall mounted outdoor service fuse units.Agency information:ASTA certifed and tested to BS88: Part 5RoHS Compliant Catalogue Numbers:DimensionsUtility Applications to BS88KR85 TypeLR85 TypeVolts:-415V Amps:- 5 - 100AIR -33kA @ 415VDimensions Volts:-415VAmps:-20 - 250AIR -80kA @ 415VData Sheet KR85:4185Data Sheet LR85:4186Data Sheet:417717For Product Data Sheets, visit J Type Fuse Links to BS88:Part 5Slotted/Non Slotted Types 415V / 20 - 800ASpecificationsDescription:Slotted type fusesdesigned for use with wedge type fuse carriers on BS applications Ratings:Applications:For use by Electrical Authorities indistribution pillars, open type substation boards, heavy duty cut-outs, and underground connection boxes.Agency information:ASTAcertified and tested BS88:Part 5RoHS Compliant Utility Applications to BS88Slotted Type (MJ31-7 up to 200A)DimensionsVolts:-415VAmps:-20 - 630A (Slotted Type)800A (Non Slotted Type)IR -80kA @ 415VCatalogue NumbersData Sheets:MJ30-8:4178A / MJ30-7:4178B / MJ31-7 or 8:4180 / PJ31:4181 / RJ:4182 / SJ:418318For Product Data Sheets, visit Cylindrical/Offset Bolted Tag 440V / 0.25 - 150ASpecificationsDescription:Cylindrical Fuse linksoriginally developped for the Admiralty but are now used in a wide variety of applicationsRatings:Applications:defence, aeronautical, allied industries,electronicsAgency information:Defence standard 59-96(superceding DEF 63). Tested to BS88 at 440V/33kA RoHS Compliant Dimensions Joint NATO Reference SystemCatalogue NumbersCylindricalOffset Bolted TagVolts:-440VAmps:-0.25 - 100A (Cylindrical)-0.5 - 150A (Offset Bolted Tag)IR -33kA @ 440VacData Sheets:size 0:4188/ size 1:4189 / size 2:4190 / size 3:419119For Product Data Sheets, visit CMCAM ASTER HRC Fuseholder690V ac / 20 - 400ASpecificationsDescription:Fully shrouded fuse bases with unique cam action system for BS88Fuse link applications.Ratings:Applications:Lighting and heating equipment,circuit protection, Motor protection, Control equipment circuit protectionAgency Information:CE Compliance to BS88, EN IEC 60269. For UL and CSA approved versions also available,consult Cooper Bussmann ®RoHS CompliantDimensionsCatalogue NumbersBS88 FuseholdersVolts:-660V acAmps:-20, 32 (Compact) 32, 63 and 100A Accesories Numbers* 200A & 400A do not have the CAM actionNotes:1 - Type CM32FC is also available rated at 20A,catalogue number CM20F2 - For colours other than Black (standard) add the appropriate letter code: W = White; G = Green,GY = Grey3 - Care must be taken when fitting solid single or stranded cables of small cross-sectional area to ensure correct clamping. Small Multi-stranded cables must be terminated with bootlace ferrules to ensure correct clamping. Bootlace ferrules should not be used on standard power cables or high current applications. If in doubt please consult Cooper Bussmann ®4 - A +5% tolerance should be allowed on dimensions when cutting metal work to fit CAMaster fuse holders20For Product Data Sheets, visit NNS,ENSSafeloc Fuseholder 660V ac / 32 - 63ASpecificationsDescription:Fuseholder to be used with BS88 Fuse links for bolted panel mounting or DIN rail.Ratings:Applications:Lighting and heating equipment,circuit protection, Motor protection, Control equipment circuit protectionAgency Information:CE Compliance to BS88, EN IEC 60269RoHS Compliant DimensionsCatalogue NumbersBS88 FuseholdersVolts:-550V ac, 415V ac (63A)Amps:-32, 63ANotes:1 - For colours other than Black (standard), add the appro-priate letter code: W = White, G = Green, GY = Grey, at the end of the catalogue reference.2 - Security seal (ref. 32551) available for 32A Safeloc3 - Care must be taken when fitting solid single or stranded cables of small cross-sectional area to ensure correctclamping. Small Multi-stranded cables must be terminated with bootlace ferrules to ensure correct clamping. Bootlace ferrules should not be used on standard power cables or high current applications. If in doubt please consult Cooper Bussmann ®4 - A +5% tolerance should be allowed on dimensions when cutting metal work to fit Safeloc fuse holders21For Product Data Sheets, visit Class gG (gF)250 - 400V / 0.5 - 32A Sizes:6x23,8x23,10x258x31,10x31,8x3610x38SpecificationsDescription:Cylindrical fuses for domestic protection.Available in types with and without striker indicator.Ratings:Applications:Protection of power lines, heatingcircuits, lighting circuits. electrical domestic appliances and domestic electricity metersAgency Information:NF C 62203, EN IEC 60269-3,NF marking (see references in bold in catalogue numbers chart)RoHS Compliant DimensionsCylindrical Domestic FusesVolts:-250V ac (6x23, 8x23, 10x25)400V ac (8x31, 10x31, 8x36, 10x38)Amps:-0.5 - 32AIR -6kA (6x23, 8x23, 10x25)-20kA (8x31, 10x31, 8x36, 10x36)Catalogue Numbers22*UP = Unit PackingNFC 60203For Product Data Sheets, visit AD440V ac / 15 - 90A Sizes:10x38,14x51,22x58 (cylindrical fuses)00 (Knife fuses)SpecificationsDescription:fuse cartridge type AD for fitting to circuit breakers on low-voltage branch circuits.Ratings:Applications:Fitting for circuit breakers in public branch panelsAgency Information:Conform to standards NF C 62-921, EN IEC 60269RoHS Compliant DimensionsCatalogue NumbersDomestic FusesVolts:-440V acAmps:-15 - 60A (Cylindrical fuses)-30 - 90A (Fuse size 00)IR -20kA (size 10x38)-32kA (size 14x51, 22x58, 00)23For Product Data Sheets, visit Class gG400 - 690V / 0.5 - 125A Sizes:8x31,10x38,14x51,22x58SpecificationsDescription:Cylindrical fuses for gG Industrial protection (general applications). Available with or without indicators and visual fuse activationindicator. Striker fitted to activate an auxiliary contact.Ratings:Applications:Protection of electrical distributioncircuits and electrical appliances (with the exception of electrical motors)Agency Information:EN IEC 60269RoHS Compliant DimensionsVolts:-400, 500, 690V ac Amps:-0.25 - 125AIR -20kA - 400V ac (size 8 x 31)-120kA - 400 and 500V ac -80 kA - 690V acCatalogue Numbers24*UP: Unit PackingFor Product Data Sheets, visit Class aM400 - 690V / 0.16 - 125A Sizes:8 x 31,10 x 38,14 x 51,22 x 58SpecificationsDescription:Cylindrical fuses for aMindustrial protection range (protection of motors).Available in types without indicators, with visual fuse activation indicator and plunger for activation of an auxiliary contact. Ratings:Applications:Direct protection of motorsAgency information:Conform to standard EN IEC 60269RoHS Compliant DimensionsCatalogue NumbersVolts:-440, 500, 690V ac Amps:-0.16 - 125AIR -20kA - 400V ac (size 8 x 31)120kA - 400 and 500V ac 80kA - 690VacNeutral Cartridges25*UP: Unit PackingLow Voltage Fuse Links Catalogue For Product Data Sheets, visit CHD250 - 400V / 10 - 32ASizes:8x23,10x25,8x3110x31,10x38SpecificationsDescription:Fuse Holder for domestic cylindrical fuses. Secured to DIN rail and available with lightindicator for active fuse function. Range as single-pole and single-pole plus neutral in one module. Ratings:Applications:Protection for power lines, heating circuits, lighting circuits. electrical domestic appliances and domestic electricity metersAgency Information:NF C 62203, EN IEC 60269-3,NF marking on all modelsModular Domestic Fuse HoldersVolts:-250V ac (8x31, 10x25)-400V ac (8x31, 10x31, 10x38)Amps:-10 - 32AIR -6kA (6x23, 8x23, 10x25)-20kA (8x31, 10x31, 8x36, 10x38)Catalogue NumbersUP: Unit Packing26For Product Data Sheets, visit CHM690V / 25 - 32A Sizes:8x31,10x38SpecificationsDescription:Fuse Holder forcylindrical industrial fuses. Secured toDIN rail and available with and without light indicator for active fuse function. Range as multi-pole and single-pole plus neutral fuse holders in one module. Accessories for the assembly of modules.Ratings:Applications:Protection of industrial electrical distribution circuits and electrical appliancesAgency Information:EN IEC 60269-3, EN IEC 60947DimensionsCylindrical Industrial FusesVolts:-690V ac Amps:-25 - 32ACatalogue NumbersCatalogue Number27For Product Data Sheets, visit Cylindrical Industrial FusesCH690V / 50 - 125ASizes:14 x 51,22 x 38SpecificationsDescription:Fuse Holders forcylindrical industrial fuses. Secured to DIN rail and screwed. Availablewith and without light indicator for active fuse function and with auxiliary contact for use with plunger fuses.The auxiliary contact is available in two versions: one for the detection of fuse actuation and pre-disconnected,and the other fuse actuation only.Ratings:Applications:Protection of industrial circuits and electrical appliances.Agency Information:EN IEC 60269-3, EN IEC 60947Dimensions 14 x 51Volts:-690V ac Amps:-25 - 32ACatalogue NumbersCatalogue Numbers22 x 5828*UP: Unit Packing*UP: Unit PackingFor Product Data Sheets, visit NH Fuses - Dual IndicatorClass gG - Low Power Loss 400V / 2 - 630ASizes 000,00,01,1,02,2,03,3SpecificationsDescription:Low Power Loss NH Fusesfor industrial protection, gG range (generalprotection). Dual Indicator system for fuse operation function (in the body and in the side plate). Version with voltage free metal gripping lugs for insulated fuses. The components used are lead and cadmium free. Fuses subject to HRC recycling commitment.Ratings:Applications:Protection of large electric distribution networks, cables and distribution boards where theminimization of power losses is a requirement. Electrical utilities and electrical distribution networksStandards and Approvals:Conform to standards EN IEC 60269, VDE 0636, DIN 43620, VDE approval.Dimensions:see page 35Catalogue Numbers29Volts:-400V ac Amps:- 2 - 630AIR -120kA - 400V acData Sheets:720097 / 720099For Product Data Sheets, visit NH Fuses - Dual IndicatorClass gG - Low Power Loss 500V / 2 - 1600ASizes C00,0,1,2,3,4,4ASpecificationsDescription:Low Power Loss NH Fusesfor industrial protection, gG range (general protection). Dual Indicator system for fuseoperation function (in the body and in the side plate) except for the sizes 4 & 4A. Version with voltage free metal gripping lugs for insulated fuses. The components used in manufac-ture are lead and cadmium free. Fuses subject to HRC recy-cling commitment.Ratings:Applications:Protection of large electric distribution networks, cables and distribution boards (except motors)where the minimize of power losses is a requirement. Standards and Approvals:Conform to standards EN IEC 60269, VDE 0636, DIN 43620, VDE approval.Dimensions:see page 35Catalogue Numbers30Volts:-500V ac Amps:- 2 - 1600AIR -120kA - 500V ac-50kA - 250V dcData Sheets:2142For Product Data Sheets, visit Class gG690V / 2 - 630ASizes 000,00,0,1,2,3SpecificationsDescription:NH Fuses for gG range industrial protection (generalprotection). Double indicator system for fuseoperation (in the body and in the side plate). Version with voltage free metal gripping lugs for insulated fuses. The components used in manufacture are lead and cadmium free. Fuses subject to HRC recycling commitment.Ratings:Applications:Protection of electrical distribution circuits,cables and electrical appliances (with the exception of motors).Standards and Approvals:Conform to standards EN IEC 60269, VDE 0636, DIN 43620.Dimensions:see page 35NH Fuses - Dual IndicatorCatalogue Numbers* Contact Cooper Bussmann for availibility** Interrupting Rating for the 35 A size 000 is 80kA31Volts:-690V ac Amps:- 2 - 630AIR -120kA - 690V acLow Voltage Fuse Links Catalogue NH Fuses - Dual IndicatorClass aM 500 - 690V / 2 - 630A Sizes 000, 00, 0, 1, 2, 3ACatalogue NumbersaM Rated Dual Indicator Unit Current voltage conducting voltage free metal Packing (A) gripping lugs gripping lugs 2 4 6NHM000B-690 10NHM000B-690 16NHM000B-690 20NHM000B-690 25NHM000B-690 32NHM000B-690 35NHM000B-690 40NHM000B-690 50NHM00B 63NHM00B 80NHM00B 100NHM00B 160NHM00B 6NHM0B 10NHM0B 16NHM0B 20NHM0B 25NHM0B 32NHM0B 35NHM0B 40NHM0B 50NHM0B 63NHM0B 80NHM0B 100NHM0B 63NHM1B-690 80NHM1B 100NHM1B 125NHM1B 160NHM1B 200NHM1B 224NHM1B 250NHM1B 125NHM2B-690 160NHM2B-690 200NHM2B-690 224NHM2B-690 250NHM2B-690 315NHM2B-690 355NHM2B-690 400NHM2B 315NHM3B-690 355NHM3B-690 400NHM3B-690 500NHM3B-690 630NHM3B 6NHM000BI-690 10NHM000BI-690 16NHM000BI-690 20NHM000BI-690 25NHM000BI-690 32NHM000BI-690 35NHM000BI-690 40NHM000BI-690 50NHM00BI 63NHM00BI 80NHM00BI 100NHM00BI 160NHM00BI 63NHM1BI-690 80NHM1BI 100NHM1BI 125NHM1BI 160NHM1BI 200NHM1BI 224NHM1BI 250NHM1BI 125NHM2BI-690 160NHM2BI-690 200NHM2BI-690 224NHM2BI-690 250NHM2BI-690 315NHM2BI-690 355NHM2BI-690 400NHM2BI 315NHM3BI-690 355NHM3BI-690 400NHM3BI-690 500NHM3BI-690 630NHM3BI 3 3 3 3 3SizeSpecifications Description: NH Fuses for aM range industrial protection (general protection). Double indicator system for fuse operation (in the body and in the side plate). Version with voltage free metal gripping lugs for insulated fuses. The components used in manufacture are lead and cadmium free. Fuses subject to HRC recycling commitment. Ratings: Volts: - 690V ac Amps: - 25 - 32A IR - 80 kA - 500Vac (sizes 000,00 - up to 100A) - 120kA - 500Vac/690Vac Applications: Protection of electrical motors. Standards and Approvals: Conform to standards EN IEC 60269, VDE 0636, DIN 43620. Dimensions: see page 350 0006 10 16 20 25 32 35 40 50 00 63 80 100 160 6 10 16 20 25 32 35 40 50 63 80 100 50 63 80 1 100 125 160 200 224 250 63 80 100 125 2 160 200 224 250 315 355 400 250 315 3 355 400 500 630332For Product Data Sheets, visit Low Voltage Fuse Links Catalogue NH FusesClass aM 500V / 2 - 630A Sizes C00, 0, 1, 2, 3Catalogue NumbersSize Rated current (A) 2 4 6 10 C00 16 20 25 32 40 50 63 80 00 100 125 160 32 50 63 80 100 125 160 40 50 63 80 1 100 125 160 200 250 100 125 160 200 250 315 355 400 315 3 400 500 630 Voltage conducting gripping lugs 2NHC00M 4NHC00M 6NHC00M 10NHC00M 16NHC00M 20NHC00M 25NHC00M 32NHC00M 40NHC00M 50NHC00M 63NH00M 80NH00M 100NH00M 125NH00M 160NH00M 32NH0M 50NH0M 63NH0M 80NH0M 100NH0M 125NH0M 160NH0M 40NH1M 50NH1M 63NH1M 80NH1M 100NH1M 125NH1M 160NH1M 200NH1M 250NH1M 100NH2M 125NH2M 160NH2M 200NH2M 250NH2M 315NH2M 355NH2M 400NH2M 315NH3M 400NH3M 500NH3M 630NH3M 120kA 3 120kA 3 120kA 3 120kA 3 Disconnect Power (kA) Unit PackingSpecifications Description: NH Fuses for aM range industrial protection (general protection). Indicator for fuse activation in the side panel. The components used in manufacture are lead and cadmium free. Fuses subject to HRC recycling commitment. Ratings: Volts: Amps: IR -500V ac 2 - 630A 120kA - 500Vac 50kA - 250V dcApplications: Protection of direct starter motors Standards and Approvals: Conform to standards EN IEC 60269, VDE 0636, DIN 43620. Dimensions: see page 350120kA32120kA3For Product Data Sheets, visit 33Low Voltage Fuse Links Catalogue NH Fuses with StrikerClass gG - aM 500 - 690V / 63 -1250A Sizes 1, 2, 3, 4Catalogue NumbersRated Current (A) 63 80 100 1 125 160 200 224 250 125 160 200 224 250 315 355 400 315 3 355 400 500 630 500 4 630 800 1000 1250 gG Voltage conducting metal gripping lugs 63NHG1BS-690* 80NHG1BS-690* 100NHG1BS-690* 125NHG1BS-690* 160NHG1BS-690* 200NHG1BS-690* 125NHG2BS-690* 160NHG2BS-690* 200NHG2BS-690* 224NHG2BS-690* 250NHG2BS-690* 315NHG2BS-690* 315NHG3BS-690* 355NHG3BS-690* 400NHG3BS-690* 500NHG3BS-690* 630NHG3BS-690* 500NH4G-S 630NH4G-S 800NH4G-S 1000NH4G-S 1250NH4G-S aM Voltage conducting metal gripping lugs 63NHM1BS-690* 80NHM1BS-690* 100NHM1BS-690* 125NHM1BS-690* 160NHM1BS-690* 200NHM1BS-690* 224NHM1BS-690* 250NHM1BS-690* 125NHM2BS-690* 160NHM2BS-690* 200NHM2BS-690* 224NHM2BS-690* 250NHM2BS-690* 315NHM2BS-690* 355NHM2BS-690* 400NHM2BS-690* 400NHM3BS-690* 500NHM3BS-690* 630NHM3BS-690* 3 3 3 Pack QtySizeSpecifications Description: NH Fuses for industrial applications class gG and aM with integrated side striker for visual or remote indication of the fuse status. To be used with NH fuse holders fitted with micro-switch. Ratings: Volts: Current IR 500V ac Size 4 690V ac Size 1,2,3 63A - 1250A 120kA - 500V ac 80kA - 690V ac23Applications: Protection of electrical distribution circuits (Class gG) and motor protection (Class aM) Standards and Approvals: Conform to standards EN IEC 60269, VDE 0636, DIN 43620.* Contact Cooper Bussmann for availibility34For Product Data Sheets, visit 。
Eaton Bussmann 系列 10 x 38 mm 模块保护丝吊挂器介绍说明书

720147Product descriptionEaton’s Bussmann ® series 10 x 38 mm modular fuse holders provide more space for cabling thanks to their compact design and are suitable for most applications including photovoltaic.Features•Colour coded for simple visual identification: yellow for PV (1000 V d.c.), red for IEC (690 V a.c.) and black for UL (600 V a.c./V d.c.) applications•CHPV models, with 1000 V d.c. rating for use with solar gPV fuse links are suitable for photovoltaic applications of any size •Tested to a wide range of standards: IEC, cULus, CCC, CSA and UR allowing for use across global applications•World class footprint - smaller than any other modular fuse holders, reducing installation space required•Toolless DIN-Rail mounting, improves ease of use and reduces installation time and costs •Rated for use with 75o C or 90o C wire,fine stranded wire, spade terminals and with comb-bus bars. Use any higher temperature rated wire with appropriate derating.10 x 38 mm Modular fuse holdersBUSSMANNSERIES2Technical Data 720147Effective October 201710 x 38 mm Modular fuse holdersEATON Catalogue symbol:•See table belowT echnical data:Rated voltage and current: see table below Terminal size: 1 to 25mm 2 (#18 to #4)Torque rating: IEC only: 2.5N•m maximumUL only: 3.4N•m (30Lb-In) maximumFlammability ratings: UL94V0, self-extinguishing Storage and operating temperature range:-20o C to +90o C (indicating)-20o C to +120o C (non-indicating)Standards/Approvals:• IEC 60269-1 and 60269-2• UL File E14853, guide IZLT Listed, IZLT2 Recognised •CSA File 47235• CHPV and CHM - Class 6225-30•CHCC - Class 6225-01•CCCPack quantity• 1-pole: 12• 2-pole: 6 • 3-pole: 4•4-pole: 3T able 1. Technical dataCatalogue NumberRated voltage and Agency Number Terminal Rated breaking Eaton’s Bussmann seriesWith Without3Technical Data 720147Effective October 201710 x 38 mm Modular fuse holdersEATON Features4mm Lockout Feature in Toolless Ganging ofMultiple PolesMountingLengthIndicatorBox Lug Cable Terminal to Accept 4-18AWG Wire, 1 to 25mm cable or 6mm Bus Bar ConnectionCaptive, Fully Backed Out Phil-Slot ScrewSpade Lug ConnectionSelf-Extinguishing,UL 94V0 Rated Polyester Hole for Wire Security TagMulti-Pole gangingUse multi-pole connection kit part number JV-L to gang multiple poles together.JV-L kit is sufficient to gang up to 4 poles.Technical Data 720147Effective October 201710 x 38 mm Modular fuse holdersEatonEMEA Headquarters Route de la Longeraie 71110 Morges, Switzerland Eaton Electrical Products Limited Melton RoadBurton-on-the-WoldsLeicestershire, LE12 5TH United Kingdom © 2017 EatonAll Rights Reserved PDF OnlyPublication No. 720147 October 2017Eaton is a registered trademark.All other trademarks are property of their respective owners.Dimensional data - mm (in)7073.961.8Removing instructions1 Press down on top of DIN-Rail2 - Rotate out on the bottomChanges to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations.。
Bussnann巴斯曼一次性保险丝

Bussnann(巴斯曼)一次性保险丝Bussmann公司在全球的雇员人数超过5000名,其中包括电气、机械、应用方面的工程师以及制造和技术支持人员。
Cooper Bussmann公司的产品多达75000多种,是唯一提供电气,电子全套电路保护产品和方案的。
产品种类包括:电气电源熔断器,电子电路板及小型熔断器,熔丝盒,熔丝座及断开开关,半导体熔断器,中高压熔断器,高速熔断器,通讯保护产品,国际标准工业熔断器,熔断器附件、显示器、工具包,熔断器技术,功率磁性元器件,超级电容,接线盒,车用熔断器和断路器。
针对电气和电子系统出现电路过载的情况,Cooper Bussmann为客户提供革新性的过载保护案。
作为熔断器和熔断保护方案的领先生产商之一,Cooper Bussmann为电路保护和控制问题提供清晰、前沿的解决方案。
Cooper Bussmann产品线不断增长,目前产品种类超过75,000多种(其中包括熔断器、熔断器底座、接线盒、电压浪涌保护器、电感器盒小型变压器等),为电路保护树立了行业标准。
Cooper Bussmann熔断器技术的研发与支持是由技术精湛且责任心极强的团队所完成的,他们共同努力,为客户提供超值的服务。
今天我简单介绍一下巴斯曼的一次性保险丝。
一、贴片系列:(1)CC12H系列:大小为3.2*1.6MM,熔断速度为快断,电流从0.75A-20A,电压从32V-63V。
特点:无卤、铅自由,通过无铅认证高I2t 1206足迹表面安装保险丝高侵入承受能力优秀的温度和循环特征通过无铅认证,无铅无卤建设兼容焊料回流和波焊应用程序:平板显示器和电视机汽车信息娱乐和ECU计算机服务器便携式电子设备手机充电器(2)CC06H系列:0603体积,大小为1.6*0.8MM,熔断速度为快断,电流从1A-5A,电压都为32V。
特点:芯片CC06H系列高I2t保险丝是一个非常小的表面安装保险丝(0603大小)旨在保护低压电路短路的有害影响。
Eaton Bussmann系列紧速熔断器说明说明书

EB
Watts loss / percent of rated current
@ 80% 3.8 4.5 5.3 6.1 7.6
12.0 14.3 16.7 19.1 26.1 29.0 34.8 40.6 46.4
@ 50% 1.3 1.5 1.8 2.0 2.5 3.6 4.3 5.1 5.8 7.0 7.8 9.4
File 53787 • IEC aR (self certified) • CE • RoHS compliant • REACH declaration available upon request
Catalog numbers:
Recommended fuse blocks Up to 100 amps
#14-2/0 Cu
1/4-20 x 1/2
See data sheet No. 1200 (BH-01_) and No. 1206 (1BS101) for details.
Up to 400 amps
Catalog ers Wire size
Stud size
BH-1131
#6-250kcmil Cu 1/4-20
• Innovative design allows for a significantly smaller package without compromising heat rise performance, preventing extensive equipment redesign.
• Global acceptance with UL®, CSA® and IEC® for products sold worldwide.
Compact high speed fuses
Bussmann 系列模块式保护器说明书

Recommended Bussmann series DIN-Rail end stops:
• Cat. no. BRKT-ND • Cat. no. BRKT-NDSCREW2
Table 3. Catalog numbers
#10-32 Phil-slot screw BCM603-1S BCM603-2S BCM603-3S
— — —
Screw with quick connect* BCM603-1SQ BCM603-2SQ BCM603-3SQ BMM603-1SQ BMM603-2SQ BMM603-3SQ
Poe class CC CC CC 10x38 (13/32”x1-1/2”) 10x38 (13/32”x1-1/2”) 10x38 (13/32”x1-1/2”) 3-Pole control circuit transformer block 2-pole CC with 1-pole 10x38 (13/32”x1-½”)
33
21
1.3
.8
40
60
1.6
2.4
77 10
3.0 .4
4
.2
39
20
20
1.6
59 2.3
.8
.8
16
.6
33
1.3
BMM603-3C with CVRI-CCM covers and TM26CB marker labels
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Bussmann 自动汽车电路保护器说明说明书

We offer a large selection of Bussmann series automotive circuit breakers including both OEM-style and fuse-replacement devices.High amp circuit breakersHigh amp circuit breakers are available for automotive and marineapplications in Type I and Type III reset modes. Typically used in auxiliary and accessory circuits for trucks, busses, RVs and boats, they are available in weatherproof/waterproof panel and flush mount versions. They can also be used in battery charging systems that use battery isolators to manage and protect batteries in multi-battery installations.T ype I - automatic resetType I circuit breakers automatically reset after opening. If the fault orovercurrent condition still exists, the breaker will continue to cycle between ON and OFF positions until the overcurrent problem is corrected. Thesedevices are sometimes called "cycling breakers." Type I/Automatic Reset circuit breakers do not address, or correct, overcurrent or fault conditions. They only react by cycling OFF and ON. Any overcurrent or fault condition that causes a Type I circuit breaker to operate should be corrected as soon as possible. Continued vehicle operation with an overcurrent or fault condition (causing the Type I circuit breaker to cycle) is NOT recommended.T ype II - modified resetType II circuit breakers will remain “tripped” by an internal resistor (in the OFF position) as long as the circuit is powered. Type II breakers can be reset by turning the circuit OFF , or by turning the ignition switch to the OFF position. These devices are sometimes called "non-cycling breakers."T ype III - manual resetType III circuit breakers will remain tripped (in the OFF position) until an indicator button or lever is manually reset. Some Type III breakers areavailable with a switch feature that allows the use of an external button to de-energize the circuit.ATM footprint T ransorb, Resistor and Diodes CB229Transorb, resistor and diode electrical protection devices easily install in common ATM fuse holders and blocks. These circuit protection devicesprovide voltage and current limiting functionality and are designed for the on- and off-highway requirements of trucks, RVs, construction, agriculture, ATV and material handling equipment.•T ransorb - Protects against voltage spikes. •Clamp rating: 27 Vdc •Power rating: 1500 W •Resistor - Drops circuit voltage. •Power rating: 5 W •Resistance: 68 Ω•Diode - Prevents reverse current flow. •Amp rating: 6 AT rad’l pack*DescriptionCB22901-1.5Transorb voltage spike protector CB22902-68Resistor voltage drop device CB22903-6Diode reverse current protectorCB22903-6VDiode reverse current protector with wing key* 1 Circuit breaker per pack, 10 packs per shelf carton.ATM footprint circuit breakersType I, Type II and Type III circuit breakers match the ATM fuse footprint. Ultra-thin, to fit in tight spaces, they're the smallest automotive circuit breakers on the market and comply with SAE standard J553.CB211T ype ICB212T ype IICB233T ype III ATM circuit breaker CB222OST ype II with offset terminalsCB223OST ype III with offset terminalsMMBT ype I, GM vehiclesAutomotive circuit breakersAmps T rad’l pack*Retail pack**7-1/2CB211-7-1/2—10CB211-10BP/CB211-10-RP 15CB211-15BP/CB211-15-RP 20CB211-20BP/CB211-20-RP 25CB211-25BP/CB211-25-RP 30CB211-30BP/CB211-30-RP * 1 Breaker per pack, 10 packs per shelf carton.** 1 Breaker per pack, 5 packs per shelf carton.Amps T rad’l pack*10CB212-1015CB212-1520CB212-2025CB212-2530CB212-30* 1 Breaker per pack, 10 packs per shelf carton.Color codeAmps T rad’l pack*Tan5CB233-05Brown 7-1/2CB233-71/2Red 10CB233-10Blue 15CB233-15Y ellow 20CB233-20White 25CB233-25Green 30CB233-30* 1 Breaker per pack, 10 packs per shelf carton.Amps T rad’l pack*OEM part no.15MMB-151213517120MMB-2012135072* 1 Breaker per pack, 10 packs per shelf carton.Amps T rad’l pack*05CB222OS-0510CB222OS-1015CB222OS-1520CB222OS-2025CB222OS-2530CB222OS-30* 1 Breaker per pack, 10 packs per shelf carton.Amps T rad’l pack*05CB223OS-057-1/2CB223OS-7-1/210CB223OS-1015CB223OS-1520CB223OS-2025CB223OS-2530CB223OS-30* 1 Breaker per pack, 10 packs per shelf carton.Low-profile ATM circuit breaker CB234T ype IIIColor code Amps T rad'l pack*Tan 5CB234-05Brown 7-1/2CB234-7-1/2Red 10CB234-10Blue 15CB234-15Y ellow 20CB234-20White 25CB234-25Green30CB234-30* 1 Breaker per pack, 10 packs per shelf carton.18For product information and data sheets, visit /BussmannConsumer。
埃森·布莱森Bussmann红色点标准工业保持器说明书
10024Product descriptionEaton’s Bussmann ® series Red Spot British standard industrial fuse holders address many applications needs.Features• They are fully shrouded for greater safety. •The high resistance body material helps ensure high dielectric strength. •The extremely reliable contact system ensures superior electrical conductivity.Red Spot BS Industrial fuse holdersBUSSMANNSERIESTechnical Data 10024Effective October 2017Red Spot BS Industrial fuse holdersCatalogue symbol:• RS(amp)F: Front connected• RS(amp)P: Back stud connected• RS(amp)PH: Front/Back stud connected• RS20F: Back stud connected, flush mountedAgency information:• BS88-2• IEC 60269-2T echnical data:• Rated voltage: 690 V a.c. (BS88 and IEC 60269)• Rated current: 20 to 400 A• Terminal conductor range: 10 to 240 mm2• Maximum ambient operating temperature: 40o C• Protection index: IP20Packaging:• 20 to 63 A: 10 per pack• 100 A: 5 per pack• 200 and 400 A: 1 per packT able 1. Part numbers detailsFuse holderdescriptionColour20 A32 A63 A100 A200 A400 AT able 2. T echnical dataRated current (Amps)Ratedvoltage(V a.c.)AgencymarkingsMinimumconductorsizeMaximumconductorsizeCompatible fuselinksPackaging20690BS88-2 andIEC 60269 -21 mm210 mm2NITD, NIT1032 1 mm216 mm2TIA, AAO, H07-66010 63 4 mm250 mm2TIS, BAO10 100 6 mm270 mm2TCP, CEO5 20010 mm2120 mm2TF, DD1 40025 mm2240 mm2TM, EF1Technical Data 10024Effective October 2017 Red Spot BS Industrial fuse holdersWeights:• RS20H: 136 grams• RS20P: 180 grams• RS20PH: 150 grams• RS20F: 210 grams• RS32H: 250 grams• RS32P: 300 grams• RS32PH: 275 grams• RS63H: 325 grams• RS63P: 450 grams• RS63PH: 380 grams• RS100H: 850 grams• RS100P: 1 kg• RS100PH: 925 grams• RS200H: 2 kg• RS200P: 2.2 kg• RS200PH: 2.4 kg• RS400H: 6.2 kg• RS400P: 7.2 kg• RS400PH: 7.7 kgT able 3. AccessoriesCataloguenumbers Description Packquantity Compatible fuse linksCompatiblefuse holdersRS20LOCK Padlockable inserts20N/A RS20RS32LOCK10N/A RS32RS63LOCK10N/A RS63RS100LOCK10N/A RS100RS20RED Red warning carriers10N/A RS20RS32RED10N/A RS32RS63RED10N/A RS63RS100RED1N/A RS100P5372-10Fuse link adaptor kits1TIA, TIS, AAO, BAO RS100TCA21AD, BD, CD, DD, TBC, TC, TF RS400PD8282Terminal shroud100N/A RS20 and RS32RS-LOCK RS-RED P5372--10TCA2PD8282Technical Data 10024Effective October 2017Red Spot BS Industrial fuse holdersDimensions - mmRS20H , 20 A, Front connected72 &/($5 %86+,1*RS20P , 20 A, Back stud connectedDimensions - mm678'',$0(7(5 2) &$%/( +2/(,1 %$6( &217$&7&/21( +2/( 72 7$.(0 &+((6(+($'),;,1* 6&5(:+2/(72 &/($5 %86+,1*&/+2/( 5(48,5(' ,1 3$1(/RS20F , 20 A, Back stud connected, flush mountedDimensions - mmRS32H, 32 A, Front connected72 &/($5 %86+,1*6RS32P , 32 A, Back stud connectedDimensions - mm72 &/($5 %86+,1*RS32PH, 32 A , Front/Back stud connectedRS63H, 63 A, Front connectedTechnical Data 10024Effective October 2017Red Spot BS Industrial fuse holdersDimensions - mm72 &/($5 %86+,1*6RS63P , 63 A, Back stud connectedRS63PH, 63 A, Front/Back stud connectedTechnical Data 10024Effective October 2017Red Spot BS Industrial fuse holdersDimensions - mmRS100H, 100 A , Front connected72 &/($5 %86+,1*6RS100P , 100 A, Back stud connectedTechnical Data 10024Effective October 2017Red Spot BS Industrial fuse holdersDimensions - mm72 &/($5 %86+,1*RS100PH, 100 A, Front/Back stud connectedRS200H, 200 A, Front connected11Technical Data 10024Effective October 2017Red Spot BS Industrial fuse holdersEATON Dimensions - mmRS200P , 200 A, Back stud connectedPP72 &/($5 %86+,1*RS200PH, 200 A, Front/Back stud connected12EATON Dimensions - mm'(7$,/ $RS400H, 400 A, Front connected'(7$,/ $RS400P , 400 A, Back stud connectedEatonEMEA Headquarters Route de la Longeraie 71110 Morges, Switzerland Eaton Electrical Products Limited Melton RoadBurton-on-the-WoldsLeicestershire, LE12 5TH United Kingdom © 2017 EatonAll Rights Reserved PDF OnlyPublication No. 10024 October 2017Eaton is a registered trademark.All other trademarks are property of their respective owners.Dimensions - mm'(7$,/ $RS400PH, 400 A, Front/Back stud connectedChanges to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations.。
巴斯曼系列低档熔断器说明书
2023ContentsDescription P age Catalog symbol 2Description 2Specifications2Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Number of poles . . . . . . . . . . . . . . . . . . . . . . . .2Agency information . . . . . . . . . . . . . . . . . . . . . .2Terminals and conductors . . . . . . . . . . . . . . . .2Terminal screw torque . . . . . . . . . . . . . . . . . . .2Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Open fuse indication . . . . . . . . . . . . . . . . . . . . .2Ambient storage and operating temperature .2Flammability rating . . . . . . . . . . . . . . . . . . . . . .2Lockout/tagout provisions . . . . . . . . . . . . . . . . .2Circuit labeling provision . . . . . . . . . . . . . . . . .2Carton quantity . . . . . . . . . . . . . . . . . . . . . . . . .2Low Pro f ile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switchesDescription P age Features3Available Bussmann series fuses 3Catalog number tables4Class G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Class CC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4UL midget . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Dimensions5Panel mounting layout52Low Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget f used disconnect switches/bussmannseriesTechnical Data 10372Effective July 2023Catalog symbol:•CCPLP -(poles)-(amps)-(terminal)Description:The revolutionary Bussmann ®series Low Profile Compact Circuit Protector (CCPLP) fused disconnect switch is available in 1-, 2- and 3-pole versions for UL ® Class CC (1/10-30A), Class G (20A), and 13/32”x1-1/2” midget UL (1/10-30A) fuses .The CCPLP has the smallest footprint of any UL 98 Listed fused disconnect switch along with up to a 200kA SCCR to help improve equipment SCCR .Class CC and G versions are easily selectively coordinated with the upstream Bussmann series CUBEFuse ™ using published fuse ampacity ratio tables .Unique panel mounting permits easy integration into many panel designs and provides a high SCCR alternative to low profile circuit breakers on the market .Specifications:Ratings•Frequency•50/60Hz•Impulse voltage•8kV•Volts•600Vac (Class CC up to 30A, Class G 20A)•240Vac (13/32” x 1-1/2” midget UL 30A)•Amps•Up to 30A (UL)•SCCR•200kA (Class CC)•100kA (Class G)•10kA (13/32”x1-1/2” midget UL)Poles• 1-, 2- and 3-pole factory configured•2- and 3-pole versions feature ganged switches and phase barriers .Agency information•Finger-safe IP20 from panel front •CE compliant •RoHS compliant•For Class G fuse versions•UL 98 Listed, File E302370, Guide WHTY •For Class CC fuse versions•UL 98 Listed, File E302370, Guide WHTY•cULus to CSA Standard 22 .2 No . 4-04, File E302370, Guide WHTY7•For UL midget f use versions•UL 508 Listed, File E320230, Guide NRNT•cULus Listed to CSA 22 .2 No . 14-05, File E320230, Guide NRNT7T erminals and conductors 75°C Cu•Screw terminal - #10-32 phil-slot screw with external tooth lock washer — use with properly rated/UL Listed ring or fork terminal•Pressure plate terminal - #10-32 phil-slot screw — single 22-6AWG solid or strandedT erminal screw torque•20 Lb-In (2.2 N•m)Mounting• Front panel mounting with customer supplied M3 screws •Mounting screw torque 4-5 Lb-In (0.4-0.5 N•m)Open fuse indication*•Local open fuse indication provided by a orange neon lamp on each pole, minimum voltage 90Vac*Open fuse indication requires an energized, closed circuit with an open fuse in the CCPLP and the switch in the ON position .Ambient storage and operating temperature•-20°C to 75°C, 85% relative humidity non-condensingFlammability rating•UL 94 V2Lockout/tagout provisions•Brady pin-out device, P/N 90844Circuit labeling provisions•Accepts up to two universal marker labels (P/N TM26CB)Carton quantity•12 poles (1-pole: 12 units, 2-pole: 6 units, 3-pole: 4 units)Minimumn enclosure size•6”x6”x4” per UL 98 Listing3Technical Data 10372Effective July 2023Low Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switches /bussmannseriesFeatures:•Suitable for global installations accepting UL Class G , CC, and midget fuses•Full voltage rated up to 600Vac•High Short-Circuit Current Ratings (SCCR) up to 200kA (UL) •Mounting and panel layout dimensions match common low-profile circuit breakers to provide an easy, alternative fused circuit protection solution .•Disconnect rated to provide means for load isolation •Extremely compact design at 19mm wide per pole•Class CC version is suitable for branch circuit disconnect and branch circuit protection•Local open fuse indication on each pole standard •Finger-safe IP20 from panel front for added safety•Built-in switch handle / fuse access door interlock prohibits removing the fuse under load•Lockout/tagout provisions made by using Brady pin-out device P/N 90844*Use Brady pin-out device, P/N 90844Circuit areaLockout/ tagout provision*Phase barrierAvailable Bussmann series fuses:CC current-limiting 600Vac 1023CC FNQ-R time-delay 600Vac 1014CC KTK-R fast-acting 600Vac 1015G SC time-delay (20A)600Vac 1024M FNM time-delay 250Vac 2028M FNQ time-delay 500Vac 1012M KTK fast-acting 600Vac 1011M BAF fast-acting 250Vac 2011MKLM fast-acting600Vac20204Low Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switches/bussmannseriesTechnical Data 10372Effective July 2023Catalog numbers:Class G fusesCCPLP-1-20G-S CCPLP-1-20G-P 160020100CCPLP-2-20G-S CCPLP-2-20G-P 260020100CCPLP-3-20G-SCCPLP-3-20G-P360020100Agency information: UL 98 Listed, File E302370, Guide WHTY , CE, RoHS compliant .Class CC fusesCCPLP-2-30CC-S CCPLP-2-30CC-P 260030200—2——CCPLP-3-30CC-S CCPLP-3-30CC-P360030200—347 .5Agency information: UL 98 Listed, File E302370, Guide WHTY , cULus to CSA Standard 22 .2 No . 4-04, File E302370, Guide WHTY7, CE, RoHS compliant .13/32”x1-1/2” UL midget fusesCCPLP-2-30M-S CCPLP-2-30M-P 22403010CCPLP-3-30M-S CCPLP-3-30M-P32403010Agency information: UL 508 Listed, File E320230, Guide NRNT , cULus Listed to CSA 22 .2 No . 14-05, File E320230, Guide NRNT7, CE, RoHS compliant .The CCPLP has the smallest footprint of any UL 98 Listed fuseddisconnect switch along with up to a 200kA SCCR to help improve equipment SCCR .Built-in switch handle / fuse access door interlock prohibits removing the fuse under load .5Technical Data 10372Effective July 2023/bussmannseries Low Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switches Dimensions (reference) – in (mm):All catalog numbersPanel mounting layout (reference) – in (mm):1-, 2- and 3-poles, all catalog numbersLow Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switchesTechnical Data 10372Effective July 2023Eaton, Bussmann and CUBEFuse are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton.UL is a registered trademark of the Underwriters Laboratories, Inc.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States Eaton .comBussmann Division 114 Old State Road Ellisville, MO 63021United StatesEaton .com/bussmannseries © 2023 EatonAll Rights Reserved Printed in USAPublication No . 10372March 2023For Eaton’s Bussmann series product information,call 1-855-287-7626 or visit:/bussmannseriesFollow us on social media to get thelatest product and support information.The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive . All other copies of this document are by definition uncontrolled . This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications . Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products . Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin . Once a product has been selected, it should be tested by the user in all possible applications .。
Bussmann系列紧凑型熔断器基础CCP2B说明书
沪教版五年级语文上学期第四次月考检测考试真题班级:姓名:满分:100分考试时间:90分钟题序一二三四五六七八九十总分得分一、根据拼音写出词语。
huǐ mièfán zhílíng lóng yā yìzào shēngshǔ jiàyōu chóu qī hēi róng shùpǔ sù二、用“√”给下面的划线字选择正确的读音。
篝火(gōu gòu)燕园(yàn yān)点缀(zuì zhuì)无垠(yín xiàn)万顷(qīng qǐng)旖旎(yī yǐ)澄澈(dèng chéng)耄耋(dié zhì)渺小(miǎo miào)三、比一比,再组词。
侮(__________)陪(__________)矩(__________)谎(__________)悔(__________)赔(__________)拒(__________)慌(__________)梅(__________)培(__________)距(__________)荒(__________)四、将下列词语补充完整,并选词填空。
同(____)于尽毫不示(____)完好无(____)同心(____)力怒目(____)睁负(____)请罪(____)发冲冠完(____)归赵1.全国人们(____),众志成城,终于打赢了疫情防控阻击战。
2.既然你已经知道这本书是谁的了,就应该(____)。
3.蔺相如看见廉颇(____),勇于悔改,连忙出门迎接。
4.秦王左右的卫士想杀了蔺相如,但蔺相如(____),厉声呵斥,卫士竟不敢上前。
五、选择合适的关联词填空。
即使……也……不是……而是……只要……就……因为……所以……1.(______)调整一下马的出场顺序,(_____)能取胜。
伊顿Bussmann系列EV级车用熔断器-EVK系列(1000Vdc,15-600A)说明书
EVK Series/系列 (1000 Vdc, 15-600A) Electric Vehicle Fuses 新能源车用熔断器EVK series/系列 (1000 Vdc, 15-600A)2Electric Vehicle Fuses —EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)Eaton’s Bussmann series Electric Vehicle (EV) full range fuses for the protection of high power and auxiliary electrical systems up to 1000 Vdc in ratings from 15 to 600 amps.伊顿Bussmann 系列EV 级车用熔断器可提供主回路及辅助支路系统的全范围保护,电压达到1000V 直流,电流可以从15A 到600A.Specifications /参数:• Volts / 电压: 1000 Vdc • Amps / 电流: 15-600 A• Interrupting rating / 分断能力: Max / 最大25kA• Time constant / 时间常数: 2±0.5ms• Ambient temperature / 环境温度: -40 ~ 125ºCEVK series/系列 (1000 Vdc, 15-600A)Features /性能:• Excellent design and application experiences with EV for decades, to serve the customers globally在EV 行业内,优秀的产品设计能力和长期的应用经验,服务于世界范围内众多用户• Comply with various international and field EV application standards worldwide符合世界范围及行业内多项EV 熔断器产品标准• Higher voltage rating provides overall system with moreefficient and economical solution while meeting the needs of higher voltage battery packs在满足高压直流电池系统应用的同时,提供给系统更有效且经济的产品方案• Higher interrupting rating projects high capacity batterypacks needed for vehicle long mileage and fast acceleration requirements具有更高的分断能力,适合大容量电池系统的应用,满足车辆长续航和急加速的使用要求• To help project the life of the fuse in the application, unique driving profiles and conditions can be simulated to verify proper fuse size and performance under a wide range of driving behaviors提升了熔断器在使用过程中的寿命,在各种驾驶工况条件下,根据工况条件进行模拟和计算得出合理的参数规格• Operation as low as 135% for 15A to 200A and 200% for 225A to 600A overload provides back up protection to the battery management system能够对电池系统提供135%(15A 到200A )或200%(225A 到600A )的低电流过载保护• More wider protection range with lower MBC and higher IR, much faster opening with low temperature rise under high fault current conditions helps assure reliable protection of circuits and components更低的最小熔断电流值MBC 和更高的最大分断电流值IR ,使得产品具有更广的电流保护范围;更快的熔断速度和较低的产品温升,使得产品在线路发生故障时能提供可靠的保护Catalog symbol / 型号:EVK10-(amp)-T bolt-on /螺栓固定EVK14-(amp)-T bolt-on /螺栓固定EVK22-(amp)-T bolt-on /螺栓固定EVK25-(amp)bolt-on /螺栓固定EVK30-(amp)bolt-on /螺栓固定EVK40-(amp)bolt-on /螺栓固定EVK50-(amp)bolt-on /螺栓固定EVK60-(amp)bolt-on /螺栓固定Basic information /基本信息:P/N / 型号Current / 电流 (A)Packing quantity/包装数量(per container/每包装)Screw / 螺栓Recommended tightening torque /推荐扭矩 (N.m)EVK10-XXX-T 15202530270M5 4.5±1EVK14-XXX-T 35405075M5 4.5±1EVK22-XXX-T 607080100M69±1EVK25-XXX 708090100195M812±1EVK30-XXX 12515017520075M812±1EVK40-XXX 22525027530085M1020±1EVK50-XXX 35040028M1020±1EVK60-XXX45050055060018M1020±1Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)3Agency information /相关标准信息:• Designed to / 符合标准: UL248-20 / ISO8820-8 / JASO D622• Manufactured under ITAF16949/VDA6.3 quality system for compliance with automotive requirements在 ITAF16949/VDA6.3 质量系统下制造,符合汽车标准要求• RoHS compliant 符合RoHS 要求• REACH declaration available upon request 根据需要可提供REACH 声明Packaging and installation suggestion / 包装和安装建议:Installation method diagram 安装方式图See below table and right diagram / 见下表及右图The installation surface should be flat and clean without oil stain, etc安装表面应平整、洁净、无油污等EVK series/系列 (1000 Vdc, 15-600A)Dimensions /尺寸: mmSize 系列Current Rating 额定电流(A)A B C D E F G H J EVK1435 ~ 505163.57714.3 5.58120.815.1EVK2260 ~ 8058759022.26.5916123.2EVK14 / EVK22Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)4EVK10EVK series/系列 (1000 Vdc, 15-600A)Size 系列Current Rating 额定电流(A)A B C D E F G H EVK2570 ~ 10072.29311025.491119 2.2EVK30125 ~ 20072.29311031911253EVK40225 ~ 30072.210012238.1111328 3.5EVK50350 ~ 40072.210012250.81113285EVK60450 ~ 60072.210012263.51113406EVK25 / EVK30 / EVK40 / EVK50 / EVK60Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)5EVK series/系列 (1000 Vdc, 15-600A)0.00010.0010.010.111010010001000010100100010000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )T -C curve / 曲线Electric vehicle auxiliary fuses /新能源车用辅助支路熔断器 — EVK10-XXX-T (1000 Vdc, 15-30A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc15120700 2.80.6202271,200 3.70.7254802,20040.8306773,4004.91Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)6EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle auxiliary fuses /新能源车用辅助支路熔断器 — EVK14-XXX-T (1000 Vdc, 35-50A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc354152,1007.5 1.9406203,0008.22501,2305,5009.22.30.00010.0010.010.111010010001000010100100010000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)7EVK series/系列 (1000 Vdc, 15-600A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc603,0009,60012.2 2.4704,68815,00013.4 2.7806,05019,40015.93.2T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 —EVK22-XXX-T (1000 Vdc, 60-80A)0.00010.0010.010.111010010001000010100100010000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)8EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 —EVK25-XXX (1000 Vdc, 70-100A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc709083,40021.3 4.3801,3674,90024 4.8901,8616,30026.7 5.31002,4308,30029.65.90.00010.0010.010.111010010001000010100100010000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)9EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 —EVK30-XXX (1000 Vdc, 125-200A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc1251,6596,00033.68.4150 2.4789,00040.310.11754,42714,00042.410.62006,27221,00046.911.70.00010.0010.010.1110100100010000100100010000100000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)10EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 — EVK40-XXX (1000 Vdc, 225-300A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc2257,16224,00068.713.72509,03229,00078.715.727511,79635,00083.316.730015,26443,00087.117.40.00010.0010.010.1110100100010000100100010000100000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)11EVK series/系列 (1000Vdc, 15-600A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc35019,11769,00089.317.940028,64797,00096.219.2T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 — EVK50-XXX (1000 Vdc, 350-400A)0.00010.0010.010.1110100100010000100100010000100000V i r t u a l p r e a r c i n g T i m e (s )-Prospective Current in Ampere r.m.s.Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)12EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 —EVK60-XXX (1000 Vdc, 450-600A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc45032,604104,000113.128.350040,011120,000129.632.455053,268149,000139.634.960067,948177,000154.838.70.00010.0010.010.1110100100010000100100010000100000V i r t u a l p r e -a r c i n g T i m e (s )Prospective Current in Ampere r.m.s.Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)13EVK series/系列 (1000 Vdc, 15-600A)Electric vehicle power fuses /新能源车用主回路熔断器 — EVK series (1000 Vdc, 15-600A)Power loss curve /功率损耗曲线T emperature derating curve /温度降容曲线00.10.20.30.40.50.60.70.80.91010203040506070809100P O W E R L O S S C O R R E C T I O N F A C T O R %O FR ATED CURRENTPower loss curveElectric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)14Note:Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器— EVK 系列 (1000 Vdc, 15-600A)15EVK series/系列 (1000 Vdc, 15-600A)Eaton’s mission is to improve the quality of life and the environment through the use of power management technologies and services. We provide sustainable solutions that help our customers effectively manage electrical, hydraulic, and mechanical power – more safely, more efficiently, and more reliably. Eaton’s 2020 revenues were $17.9 billion, and we sell products to customers in more than 175 countries. We have approximately 94,000 employees.Eaton began operation in China more than 20 years ago. Since entering the Chinese market in 1993, Eaton’s presence has grown significantly in the country. In 2004, Eaton moved its Asia Pacific headquarters from Hong Kong to Shanghai.In the Greater China region, Eaton has nearly 9,800 employees,29 manufacturing bases and 5 R&D centers. T oday, we make most products for all of Eaton’s distinct business here.For more information about the company, visit For more information about Eaton China, visit Eaton China official social media account: Eaton_China伊顿公司致力于通过运用动力管理技术和服务来改善人类生活品质并提升环境质量。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Form No. BM Series
Page 1 of 1BIF Doc #1104
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin
is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
1-16-02SB02003
Dimensional Data All dimensions (±0.015)
#10-#18#10-#18#6-#14
Catalog Symbol:BM Series
Type M Supplementary Fuseblocks Ampere Rating:⁄Ω¡º to 30 Amperes Voltage Rating:600 Volts AC
Withstand Rating:10,000 A RMS Sym. or interrupting r ating of the fuse used, whichever is lower.Agency Information:
U.L. Recognized, U.L. 512, Guide IZLT2, File E14853CSA Certified, C22.2 No. 39, Class 6225-01, File 47235For use with any ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses
(Bussmann KTK, FNQ, FNM, BAF, BAN and AGU)U.L. Flammability:94 V0Material:Thermoplastic
Catalog Data (600V)
Terminal Type Screw with Quick Pressure Plate w/Box Fig.Amps Poles Connect*Quick Connect*Lug
No.⁄Ω¡º1BM6031SQ BM6031PQ BM6031B 1to 2BM6032SQ BM6032PQ BM6032B 2303
BM6033SQ
BM6033PQ BM6033B 3。