燃气电磁阀说明书

合集下载

3 2 SERIES 327 3 2 电磁阀 使用手册说明书

3 2 SERIES 327 3 2 电磁阀 使用手册说明书

NF 8,0 8,0 5,0 6,4 / 8
-20 to +60
WSCR 8,0 8,0 5,0 6,4 / 8
-20 to +60
WSCREM 8,0 8,0 5,0 6,4 / 8
-20 to +60
(2) Refer to the dimensional drawings on page 3 and 4
*ATEX/IECEx valves using these solenoids are approved according to EN ISO 80079-36 & EN ISO 80079-37 (non electrical)
Options & Accessories
spare part kit no.(1)
10
Sprinkler systems
• Direct operated, balanced poppet, 3/2-way, Normally Closed, Normally Open
valve with auto latching lever and manual override
• In normal state the Solenoid Valve is de-energized. In case of fire the Detection Unit of the
Explanation of temperature ranges of solenoid valves
Valve temperature range
The valve temperature range (TS) is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam)

VSB和VSA系列燃气安全电磁阀说明书

VSB和VSA系列燃气安全电磁阀说明书

Gas safety solenoid shut-off valve series VSB and VSA, approved according to the norm EN 161 with product identification and manufactured according to ATEX rule 94/9/CE - Zone 2 and 22 (II 3G – II 3D), are suitable for the automatic control of gases belonging to the first, second and third family.On request there are versions for biogas and air. These val -ves, normally closed for continuous and cyclic operation, open by powering the coil and close quickly when there is no tension.Safety Shut-off Valvesseries VSB and VSA• Class A, Group 2 according to EN161• Electromagnetic Compatibility – Directive 2004/108/CE • Low voltage – Directive 2006/95/CE• ATEX zones 2 and 22 (II 3G – II 3D) – Directive 94/9/CE • Normally closed• Quick and slow opening and quick closing • Quiet operation• Poliammidic resin encapsulated coils and metallic frame for flanged bodies • Pressure test points at inlet by both sides•Accessories on request: by-pass, limit switch, manual max. flow adjustmentFEATURES1Supply voltage24V ac/50 Hz110V ac/50 - 60 Hz230V ac/50 - 60 HzFLOW CHARTMolle di taratura pressioneE =24V dcF =12V dcG =12V ac / 50 HzAriaMetanoGas di cittàPropanoButanoG.P.L.dv=1dv=0,64dv=0,45dv=1,56dv=2,09AirMethaneTown gasPropaneButaneL.G.P.FLOW CHARTAria Metano Gas di cittàPropano Butano G.P .L.dv=1dv=0,64dv=0,45dv=1,56dv=2,09dv=1,70AirMethane Town gas Propane Butane L.G.P .Other accessories signal lamp by valve feeding (in the connector)limit micro-switch Flanged (only for Rp 1)Biogas versionAria Metano Gas di cittàPropano Butano G.P .L.dv=1dv=0,64dv=0,45dv=1,56dv=2,09dv=1,70AirMethane Town gas Propane Butane L.G.P .FLOW CHARTAria Metano Gas di cittàPropano Butano G.P .L.dv=1dv=0,64dv=0,45dv=1,56dv=2,09dv=1,70AirMethane Town gas Propane Butane L.G.P .SERIES VSA….. QUICK / SLOW OPENING THREADED Rp 1/2, 3/4, 1An energy saving connector Green for valuable reduction of energy consumption is also available (3 VA).SERIES VSA… QUICK / SLOW OPENING THREADED Rp 1.1/4, 1.1/2, 2SERIES VSA… QUICK / SLOW OPENING FLANGEDInstallation, adjustment and maintenance of the valve must be carried out exclusively by skilled and authorized service technicians1. Before electric wiring, check that the main voltage matches with the power supply voltage stated on the product label.2. Disconnect power before wiring.3. By wiring connector, use terminals and cables as reported in the Instruction leaflet in the package.4. Connect the power supply to terminals 1 and 2 and the ground wire to terminal .5. Using energy saving Green connector with 12 and 24 Vdc comply with polarity.1. Make sure that all operating data indicated on the safety shut-off valve label correspond to those of the system.2. Before installing the safety shut-off valve, quit the gas supply and make sure that the pipeline is free from impurities. The pipelinemust be vibration-free.3. The flow direction indicated by the arrow on the valve body must be respected, facing towards the user appliance. The safety valvecan be installed either horizontally or vertically, provided that the coil is not turned downwards.4. When installing the safety shut-off valve in pipework do not use the coil as a lever, but use the correct wrench.5. The sealing material must be applied to the external thread of the pipeline only and not to the internal thread of the safety shut-off valve.ADJUSTMENT OF FLOW RATE - OPENING TIME AND RAPID STROKE1. Coil fastening nut2. Flow rate adjustmentUnscrew the nut and spin the internal screw clockwise to reduceand counter clockwise to increase the flow rate.1. Flow rate adjustment2. Rapid stroke adjustment3. Opening time adjustmentSpin the screws clockwise to reduce each worth and counterclockwise to increase each worth.All the reported data are subject to be changed without notice. from 140906Econex s.r.l. - Via Francesco De Sanctis, 53 - I-20141 MilanoTel.+390289502912-Fax+****************************************QUICK OPENING SLOW OPENING。

煤气电磁阀说明书

煤气电磁阀说明书

一、DMF-0.1型电磁式煤气安全切断阀简介:DMF-0.1型电磁式煤气安全切断阀由本厂生产制造的新型换代产品。

电磁式煤气安全切断阀不仅克服了目前国内常用的电动切断阀切断速度慢、控制复杂等缺点,而且在断电时也能立即切断煤气,保证生产安全。

DMF-0.1型电磁式煤气安全切断阀主要由电磁式启动器和密封性能良好的蝶阀组合而合成。

且有结构简单、操作方便、工作可靠、切断速度快和密封性能好等优点。

密封圈一般为耐油橡胶,二、DMF-0.1型电磁式煤气安全切断阀用途现代以煤气为燃料的各种工业窑炉大多数均采用低压煤气烧咀,由专业风机提供燃空气。

大多数的窑炉还用了空气予热装置。

在生产过程中,一旦煤气压力过低、烧咀不能正常工作时,应立即将煤气切断并停转风机,(特别情况除外)。

这样既可保证生产安全,又不至于使炉子迅速变冷。

若煤气未能及时切断,煤气尚有一定余压,有可能通过烧咀的混合气进入风管,特别是有予热装置的风管,由于温度下降会形成一定负压,更易使煤气进入风管,而后在风管内或炉内形成爆炸性的混合物,当再次点火时往往会引起爆炸,酿成事故。

这种情况曾屡有发生。

本产品正是针对这些情况而开发设计的,是以煤气为媒料的各种工业炉窑生产安全不可缺少的理想设备。

煤气发生低压原因很多,其中也包括由于停电而引起的煤气低压,现在通用的煤气切断阀是由电机驱动的,停电时就无法动作,所以对因停电而引起的煤气低压,不能达到安全保护的作用。

本产品克服这种缺点,同时切断速度也大大高于电动切断阀,更符合安全的要求。

本产品亦可适用于有类似要求的其它场合。

三、DMF-0.1型电磁式煤气安全切断阀结构和工作原理DMF-0.1型电磁式煤气安全切断阀由气密性较高的蝶阀、牵引电磁铁、杠杆装置、锁销、重锤和弹簧等构成,其结构及工作原理(见附图1)四、DMF-0.1型电磁式煤气安全切断阀技术规格:1、电磁铁一般按交流220V,电容量约为220V A供货(特殊要求时本厂也可供货)2、阀的公称压力为PN0.1MPA。

电磁阀-VP4-50 70-OMU0001-使用说明书

电磁阀-VP4-50 70-OMU0001-使用说明书

文件No. VP4_50-OMU0001大型5通电磁阀VP4*50/VP4*70/VVP4*0系列安全注意事项 ------------------------------------------------------------ 2,3 设计注意事项/选定-------------------------------------------------------- 4,5 安装--------------------------------------------------------------------- 5配管--------------------------------------------------------------------- 6配线--------------------------------------------------------------------- 6给油--------------------------------------------------------------------- 6气源--------------------------------------------------------------------- 6使用环境----------------------------------------------------------------- 7维修保养----------------------------------------------------------------- 7产品个别注意事项--------------------------------------------------------- 8故障与处理方法----------------------------------------------------------- 9,10安全注意事项此处所示的注意事项是为了确保您能安全正确地使用本产品,预先防止对您和他人造成危害和伤害而制定的。

电磁阀使用说明书

电磁阀使用说明书

电磁阀两位三通电磁阀通常与单作用气动执行机构配套使用,两位是两个位置可控:开-关,三通是有三个通道通气,一般情况下1个通道与气源连接,另外两个通道1个与执行机构的进气口连接,1个与执行机构排气口连接,具体的工作原理可以参照单作用气动执行机构的工作原理图。

两位五通电磁阀通常与双作用气动执行机构配套使用,两位是两个位置可控:开-关,五通是有五个通道通气,其中1个与气源连接,两个与双作用气缸的外部气室的进出气口连接,两个与内部气室的进出气口接连,具体的工作原理可参照双作用气动执行机构工作原理。

在气路(或液路)上来说,两位三通电磁阀具有1个进气孔(接进气气源)、1个出气孔(提供给目标设备气源)、1个排气孔(一般安装一个消声器,如果不怕噪音的话也可以不装@_@)。

两位五通电磁阀具有1个进气孔(接进气气源)、1个正动作出气孔和1个反动作出气孔(分别提供给目标设备的一正一反动作的气源)、1个正动作排气孔和1个反动作排气孔(安装消声器)。

对于小型自动控制设备,气管一般选用8~12mm的工业胶气管。

在电气上来说,两位三通电磁阀一般为单电控(即单线圈),两位五通电磁阀一般为双电控(即双线圈)。

线圈电压等级一般采用DC24V、AC220V等。

两位三通电磁阀分为常闭型和常开型两种,常闭型指线圈没通电时气路是断的,常开型指线圈没通电时气路是通的。

常闭型两位三通电磁阀动作原理:给线圈通电,气路接通,线圈一旦断电,气路就会断开,这相当于“点动”。

常开型两位三通单电控电磁阀动作原理:给线圈通电,气路断开,线圈一旦断电,气路就会接通,这也是“点动”。

两位五通双电控电磁阀动作原理:给正动作线圈通电,则正动作气路接通(正动作出气孔有气),即使给正动作线圈断电后正动作气路仍然是接通的,将会一直维持到给反动作线圈通电为止。

给反动作线圈通电,则反动作气路接通(反动作出气孔有气),即使给反动作线圈断电后反动作气路仍然是接通的,将会一直维持到给正动作线圈通电为止。

电磁式燃气紧急切断阀说明书

电磁式燃气紧急切断阀说明书

电磁式燃气紧急切断阀说明书电磁式燃气紧急切断阀是一种重要的安全设备,其功能是在燃气泄漏或火灾等紧急情况下迅速切断燃气供应,以保障人员生命财产安全。

本说明书将详细介绍电磁式燃气紧急切断阀的性能、结构、安装、使用及维护等方面,以便用户正确选择、安装、使用和维护该设备。

一、性能介绍电磁式燃气紧急切断阀采用电磁阀控制阀门开闭,具有响应快、可靠性高、安装简便、维护方便等优点。

该阀门广泛应用于燃气管道系统中,能够切断燃气供应管道的气流,并能在管路内部使燃气隔离,有效地预防燃气泄漏和火灾等事故的发生。

二、结构介绍电磁式燃气紧急切断阀主要由电磁铁、气阀、弹簧等部件组成。

阀门采用铝合金、不锈钢等高强度材料制造,结构合理,密封性能良好。

阀门外表面通常采用喷塑或电泳处理,能够有效地防腐蚀。

三、安装注意事项1、安装前应严格检查阀门的外观和内部状况,确保阀门和管道连接的密封性。

2、阀门在安装前应进行防腐和防腐处理,以保证其使用寿命和安全性。

3、安装时阀门应根据其标志箭头的方向安装,以确保其正常工作。

4、阀门应安装在易于观察、操作和维护的地方。

5、阀门安装后应进行密封性测试。

测试时应关闭手动切断阀和其他管道,打开燃气阀门,检查阀门开启和关闭状态等。

四、使用及维护1、阀门在正常使用中应定期进行检查和维护,以确保其安全可靠。

2、在每年的开机前,应进行系统检查和维护,以确保其正常开机。

3、在安装和使用过程中,如发生故障或损坏,应及时维修或更换,以确保安全。

4、不得随意对电磁式燃气紧急切断阀进行拆卸和改动,以免影响其安全性。

总之,电磁式燃气紧急切断阀是一种重要的安全设备,在使用过程中要注意其安装、维护和管理,以消除安全隐患,确保人员的生命财产安全。

如果您对电磁式燃气紧急切断阀有任何疑问或需要帮助,请及时咨询相关专业人员。

电磁式燃气紧急切断阀说明书[001]

电磁式燃气紧急切断阀说明书[001]

电磁式燃气紧急切断阀说明书电磁式燃气紧急切断阀是一种非常重要的安全设备,它在燃气爆炸或泄漏时能够实现快速自动切断气源,起到了保护人们生命财产安全的作用。

下面,我们就来详细介绍一下电磁式燃气紧急切断阀的使用说明。

首先,使用之前要进行检查,检查是否有异常损坏或者松动、开裂等情况,如果有则需要及时更换或维修。

同时,还需要检查电缆电源是否已接好,切断阀电源是否正常,以及其他附加装置是否安装正确。

这些都是确保切断阀正常工作的重要前提。

其次,我们需要注意切断阀的安装位置和方向。

切断阀必须安装于易燃易爆场所出口处,以便在气体泄漏时可以快速切断气源,并且安装方向应与气体流向相同。

在安装时,还需要注意切断阀的紧固螺栓是否安装牢固,以及防止阀门颠簸导致内部损坏。

然后,在使用切断阀时,应该保持清洁和规律的检查,防止气体中碎屑、杂物等物质进入切断阀内部,影响其正常工作。

同时,定期进行检查和润滑,确保切断阀的灵敏度和可靠性。

最后,如果出现切断阀无法正常开启或关闭的情况,应该及时停止使用切断阀并进行检查,以防出现意外事故。

切断阀在使用过程中也需要严格遵守相关的安全操作规程,避免因操作不当导致的危险情况发生。

总而言之,电磁式燃气紧急切断阀是一种非常重要的安全设备,我们要认真注意其安装位置、方向和保养维护,确保其正常工作和发挥安全保护作用。

同时,也需要遵守安全操作规程,减少意外事故的发生。

nz200t-22gy-4说明书

nz200t-22gy-4说明书

nz200t-22gy-4说明书型号:NZ200T-22GY-4说明书一、产品概述NZ200T-22GY-4是一款高性能的工业用电磁阀,主要用于控制气体或液体的流通。

其采用先进的电磁阀技术和材料,具有结构牢固,操作可靠,使用寿命长的特点。

本说明书将对该产品的结构、性能、安装和维护等方面进行详细介绍。

二、主要技术参数1. 工作电压:AC220V/50Hz2. 工作压力范围:0-1.6MPa3. 工作介质温度:-10℃~80℃4. 阀体材质:铸铁5. 密封材料:NBR (丁腈橡胶)6. 进出口口径:G1/47. 防护等级:IP65三、产品结构NZ200T-22GY-4电磁阀由以下主要部件组成:1. 阀体:采用高强度铸铁材料,经过精密加工,具有良好的耐腐蚀性能。

2. 阀芯:采用耐高温材料制造,结构紧凑,可靠性高。

3. 电磁线圈:采用绝缘材料包裹,保证了安全可靠的电气接触。

4. 密封件:采用耐油耐酸碱性能好的NBR橡胶制成,有效防止泄漏。

5. 其他配件:包括固定螺丝和垫圈等。

四、使用环境要求1. 温度范围:-10℃~60℃。

2. 湿度范围:相对湿度不大于85%。

3. 周围环境无可燃气体或腐蚀性气体,无强烈振动和冲击。

4. 安装位置应平稳,并与输送介质方向一致,防止堵塞。

五、安装与使用1. 产品应由专业技术人员安装,并确保阀体与管路连接牢固、不漏气。

2. 在使用前,请仔细检查阀体和密封件是否完好,如有损坏需及时更换。

3. 接通电源后,可通过观察电磁线圈上的指示灯来判断电磁阀是否正常工作。

4. 操作该电磁阀时,应根据实际需要合理控制通电时间和通电频率。

5. 在长时间不使用时,应切断电源,并进行定期维护,清洁阀体和密封件。

六、维护与保养1. 常规维护:定期检查并清洁阀体和密封件,确保无杂质和泄漏。

2. 寿命维护:根据使用情况,及时更换耐磨损的部件,以延长电磁阀的使用寿命。

3. 定期检查电磁线圈的绝缘性能,如发现有损坏或老化的情况,需要及时更换。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

DN15燃气电磁阀 DN20燃气电磁阀 DN25燃气电磁阀
● 概 述:
本公司PS01A 系列燃气紧急切断电磁阀,是燃气管道的安全紧急切断装置。

它可与燃气泄漏报警系统连接或与消防及其他智能报警控制终端模块等连接,实现现场或远程自动/手动紧急切断气源,确保用气安全。

当发生有害的强烈震动时,阀门会自动关闭。

开阀须经人工干预,手动开启,满足安全管理规范,符合事故处理特点。

● 外型尺寸:
● 主要技术参数 ◆ 适用气体:天然气;石油液化气;人工煤气等 ◆ 关阀方式: 直流脉冲驱动/手动
无腐蚀性气体 ◆ 驱动电压: DC9V
~DC12V.(脉冲)
◆ 阀体材质:黄铜合金 ◆ 驱动电流: <2A (脉冲)
◆ 密封材质:NBR 橡胶 ◆ 关阀时间: 小于1秒
◆ 工作环境温度:-10℃~+50℃ ◆ 防爆类型: 浇封型
◆ 最大工作压力:50kPa ◆ 出线长度: 米
◆ 连接方式:G1/2”(DN15A)/G3/4”(DN20A)
◆ 开阀方式:手动复位
◆ 执行标准:
● 原 理
该阀巧妙利用瞬时电磁力与永磁力及弹簧力的相互作用,实现脉冲驱动自保持关阀及手动开阀自保持功能。

关阀驱动原理:瞬时直流脉冲驱动关阀(DC 9V ~12V/1s )
例:电容放电方式驱动电路原理图:
电磁阀
DC9V ~12V GND
470uf~1000uf /35V
10K 白 DC 黑
防护盖
红色拉柄
执行机构 控制电缆 阀体
玑法 燃气紧急切断电磁阀说明书 型号: PS01A DN15A/DN20A 台州磐石金属制品有限公司
● 操作说明
1. 阀门在开启状态有两种关阀方式:① 给电磁线圈提供一个(约1秒)瞬时直流脉冲(DC 9~12V ) 电能,阀门则快速关闭; ② 打开防护盖,手动压下红色手柄也可关阀。

关阀后状态自保持。

注意:通常情况不宜打开防护盖,以免误操作关阀。

2. 阀门在关闭状态只有一种开阀方式:手动用力向上拉起红色手柄,即可开阀。

开阀状态可自保持。

注意:开阀时,如手柄向上提拉困难,则应采取措施使阀门两端进、出口压力平衡,平衡后再开阀。

切忌野蛮操作,以免损坏开阀执行机构。

3. 阀门在开启状态:由于采用磁锁原理设计,因此阀门在遇有害的强烈震动时,阀门可能会自动关闭, 属正常情况。

如果开阀自锁力不正常(过小),则应通知厂家维修。

4. 当阀门紧急切断后,须人工现场确认,排除事故隐患方能手动复位,恢复通气。

● 安装要求
1. 阀门安装单位应具备相应资质并按相关的燃气管道施工规范安装。

2. 阀门应安装在户内的总进气阀之后,以便检修。

3. 应按阀体标明的气流方向安装,阀体线圈不得倒立,允许水平和垂直安装。

4. 电磁阀控制线应正确可靠连接,控制线有极性:白色线为正极、黑色线为负极,不能接反。

5. 管道吹扫时,建议将电磁阀隔离,以免管内杂物损坏阀门密封材料。

6. 管道在进行试压检测密封性能前,应先使电磁阀处开阀状态。

7. 手动开阀时,宜在阀门进出口压力平衡时操作。

8. 电动关阀时,切忌接错电源,如:接错极性、加错电压或长时间通电等,以免损坏电磁线圈。

9.
任何因保管不善、违章施工造成阀门损坏、部件丢失,不属于本公司免费保修范围。

● 家用型紧急切断电磁阀安装指导
家用型电磁阀安装示意图 产品在民宅内应用示意图
● 布线要求
电缆线:建议采用双芯护导线2×,接线采用端子压接方式;
控制距离:电容放电驱动方式,布线长度小于50 米。

● 阀门维护
建议用户定期对阀门进行开、关检查,如发现故障,应及时通知专业人员或厂家检修。

致力为燃气专业用户提供可信赖的安全产品
我们所有的努力都是为了让顾客更满意
感谢您的选择! 燃气具。

相关文档
最新文档